7/25/2019 2G 8000 - 8999 Transmission Alarms http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 1/486 Nokia Siemens Networks GSM/EDGE BSS, Rel. RG20(BSS), Operating Documentation, Issue 03 Reference Transmission Equipment Alarms (8000- 8999) DN998797 Issue 8-1 Approval Date 2010-10-15 Confidential

Upload: brightmsfstar

Post on 25-Feb-2018

232 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 1/486

Nokia Siemens Networks

GSM/EDGE BSS, Rel.

RG20(BSS), OperatingDocumentation, Issue 03

Reference

Transmission Equipment Alarms (8000-

8999)

DN998797

Issue 8-1

Approval Date 2010-10-15

Confidential

Page 2: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 2/486

2 DN998797

Issue 8-1

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804cd6

Confidential

The information in this document is subject to change without notice and describes only the

product defined in the introduction of this documentation. This documentation is intended for the

use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted

in any form or means without the prior written permission of Nokia Siemens Networks. The

documentation has been prepared to be used by professional and properly trained personnel,

and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes

customer comments as part of the process of continuous development and improvement of the

documentation.

The information or statements given in this documentation concerning the suitability, capacity,

or performance of the mentioned hardware or software products are given "as is" and all liability

arising in connection with such hardware or software products shall be defined conclusively and

finally in a separate agreement between Nokia Siemens Networks and the customer. However,

Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions

contained in the document are adequate and free of material errors and omissions. Nokia

Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which

may not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO

EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-

TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-

RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED

TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY

OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION

IN IT.

This documentation and the product it describes are considered protected by copyrights and

other intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark

of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2010. All rights reserved

f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources

of danger.

Only trained and qualified personnel may install, operate, maintain or otherwise handle

this product and only after having carefully read the safety information applicable to this

product.

The safety information is provided in the Safety Information section in the “Legal, Safety

and Environmental Information” part of this document or documentation set.

The same text in German:

f Wichtiger Hinweis zur ProduktsicherheitVon diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder

andere Gefahrenquellen ausgehen.

Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch

geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-

anforderungen erfolgen.

Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal,

Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentations-

satzes.

Page 3: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 3/486

DN998797 3

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804cd6

Confidential

Table of contentsThis document has 487 pages.

Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

1 List of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

2 Transmission equipment parameters (DX 200 Alarm System). . . . . . . 18

3 Transmission equipment parameters (BTS Alarm System) . . . . . . . . . 23

4 8000 POWER SUPPLY FAULT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

5 8001 TOTAL LOSS OF POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . 30

6 8002 LOSS OF BACK UP POWER SUPPLY . . . . . . . . . . . . . . . . . . . . 32

7 8003 LOSS OF REMOTE POWER SUPPLY . . . . . . . . . . . . . . . . . . . . 34

8 8004 UNBALANCE IN REMOTE POWER SUPPLY . . . . . . . . . . . . . . . 36

9 8005 INCORRECT RINGING VOLTAGE . . . . . . . . . . . . . . . . . . . . . . . 38

10 8006 FAULT IN CENTRAL BATTERY. . . . . . . . . . . . . . . . . . . . . . . . . . 40

11 8007 FAULT IN CRITERIA VOLTAGE . . . . . . . . . . . . . . . . . . . . . . . . . 42

12 8008 LOW BATTERY VOLTAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

13 8009 FAULT IN CURRENT LOOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

14 8010 SUPPLY UNIT VOLTAGE INCORRECT . . . . . . . . . . . . . . . . . . . 48

15 8011 DISTRIBUTION FUSE FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

16 8012 SIGNALLING VOLTAGE FAULT . . . . . . . . . . . . . . . . . . . . . . . . . 52

17 8013 CHARGER FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

18 8014 AC INPUT VOLTAGE FAILURE. . . . . . . . . . . . . . . . . . . . . . . . . . 56

19 8016 MAIN FUNCTION INHIBITED. . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

20 8017 SIGNAL LOOPED TO TERMINAL . . . . . . . . . . . . . . . . . . . . . . . . 60

21 8018 SIGNAL IS LOOPED TO TRANSMISSION PATH . . . . . . . . . . . . 62

22 8019 FUNCTION INHIBITED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6423 8020 BLOCKED FROM USE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

24 8021 LOOP TO INTERFACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

25 8022 LOOP TO EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

26 8023 TEST MODE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

27 8024 LOOP IN EQUIPMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

28 8025 TEST GENERATOR ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

29 8026 EXTERNAL TEST MODE ACTIVE. . . . . . . . . . . . . . . . . . . . . . . . 78

30 8027 BLOCKED FROM FAR END . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

Page 4: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 4/486

4 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804cd6

Confidential

31 8028 TIMESLOT RESERVED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

32 8032 LOSS OF OUTGOING SIGNAL. . . . . . . . . . . . . . . . . . . . . . . . . . . 84

33 8033 LOSS OF OUTGOING 64K SIGNAL . . . . . . . . . . . . . . . . . . . . . . . 86

34 8034 LOSS OF OUTGOING 2M SIGNAL. . . . . . . . . . . . . . . . . . . . . . . . 88

35 8035 LOSS OF OUTGOING 8M SIGNAL. . . . . . . . . . . . . . . . . . . . . . . . 90

36 8036 LOSS OF OUTGOING 34M SIGNAL. . . . . . . . . . . . . . . . . . . . . . . 92

37 8037 LOSS OF OUTGOING 140M SIGNAL. . . . . . . . . . . . . . . . . . . . . . 94

38 8038 LOSS OF OUTGOING 560M SIGNAL. . . . . . . . . . . . . . . . . . . . . . 96

39 8039 LOSS OF OUTGOING 0.7M SIGNAL . . . . . . . . . . . . . . . . . . . . . . 98

40 8040 NO FREE CHANNEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100

41 8042 LOSS OF OUTGOING TRANSMISSION PATH SIGNAL . . . . . . 102

42 8043 INCORRECT OUTGOING SIGNAL LEVEL. . . . . . . . . . . . . . . . . 104

43 8044 HIGH REFLECTED POWER. . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

44 8045 NO OUTGOING SIGNAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108

45 8046 NO OUTGOING LINE SIGNAL . . . . . . . . . . . . . . . . . . . . . . . . . . 110

46 8047 PAYLOAD MISMATCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

47 8048 LOSS OF INCOMING SIGNAL . . . . . . . . . . . . . . . . . . . . . . . . . . 114

48 8049 LOSS OF INCOMING 64K SIGNAL . . . . . . . . . . . . . . . . . . . . . . 116

49 8050 LOSS OF INCOMING 2M SIGNAL . . . . . . . . . . . . . . . . . . . . . . . 118

50 8051 LOSS OF INCOMING 8M SIGNAL . . . . . . . . . . . . . . . . . . . . . . . 120

51 8052 LOSS OF INCOMING 34M SIGNAL . . . . . . . . . . . . . . . . . . . . . . 122

52 8053 LOSS OF INCOMING 140M SIGNAL . . . . . . . . . . . . . . . . . . . . . 124

53 8054 LOSS OF INCOMING 560M SIGNAL . . . . . . . . . . . . . . . . . . . . . 126

54 8055 LOSS OF INCOMING 0.7M SIGNAL. . . . . . . . . . . . . . . . . . . . . . 128

55 8056 LOSS OF INCOMING 1.5M SIGNAL. . . . . . . . . . . . . . . . . . . . . . 130

56 8057 LOSS OF POINTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132

57 8058 LOSS OF INCOMING TRANSMISSION PATH SIGNAL. . . . . . . 134

58 8059 INCORRECT INCOMING SIGNAL LEVEL . . . . . . . . . . . . . . . . . 136

59 8060 NO INCOMING RADIO SIGNAL . . . . . . . . . . . . . . . . . . . . . . . . . 138

60 8061 LOSS OF INCOMING LINE SIGNAL. . . . . . . . . . . . . . . . . . . . . . 140

61 8062 NO CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142

62 8063 NO REDUNDANT CONNECTION. . . . . . . . . . . . . . . . . . . . . . . . 144

63 8064 ALARM SIGNAL (AIS) IS RECEIVED . . . . . . . . . . . . . . . . . . . . . 146

Page 5: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 5/486

DN998797 5

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804cd6

Confidential

64 8065 ALARM SIGNAL (AIS 64K) IS RECEIVED. . . . . . . . . . . . . . . . . 148

65 8066 ALARM INDICATION SIGNAL (AIS) RECEIVED. . . . . . . . . . . . 150

66 8067 ALARM SIGNAL (AIS 8M) IS RECEIVED . . . . . . . . . . . . . . . . . 152

67 8068 ALARM SIGNAL (AIS 34M) IS RECEIVED . . . . . . . . . . . . . . . . 154

68 8069 ALARM SIGNAL (AIS 140M) IS RECEIVED . . . . . . . . . . . . . . . 156

69 8070 ALARM SIGNAL (AIS 560M) IS RECEIVED . . . . . . . . . . . . . . . 158

70 8071 ALARM SIGNAL (AIS 0.7M) IS RECEIVED . . . . . . . . . . . . . . . . 160

71 8072 ALARM SIGNAL (AIS 16K) IS RECEIVED. . . . . . . . . . . . . . . . . 162

72 8073 ALARM INDICATION SIGNAL (AIS) RECEIVED. . . . . . . . . . . . 164

73 8074 ALARM INDICATION SIGNAL RECEIVED ON TIMESLOT 16 . 166

74 8075 S ALARM RECEIVED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168

75 8076 GENERAL ALARM IN NETWORK RECEIVED . . . . . . . . . . . . . 170

76 8077 LOOPED SIGNAL RECEIVED . . . . . . . . . . . . . . . . . . . . . . . . . . 172

77 8078 MEASUREMENT SIGNAL RECEIVED . . . . . . . . . . . . . . . . . . . 174

78 8079 TS16 CODE ERROR RECEIVED. . . . . . . . . . . . . . . . . . . . . . . . 176

79 8080 FRAME ERROR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178

80 8081 LOSS OF FRAME ALIGNMENT. . . . . . . . . . . . . . . . . . . . . . . . . 180

81 8082 MULTIFRAME ALIGNMENT LOST . . . . . . . . . . . . . . . . . . . . . . 182

82 8083 LOSS OF FRAME ALIGNMENT OF SUBSYSTEM . . . . . . . . . . 184

83 8084 LOSS OF LINE FRAME ALIGNMENT . . . . . . . . . . . . . . . . . . . . 186

84 8085 LOSS OF RADIO FRAME ALIGNMENT . . . . . . . . . . . . . . . . . . 188

85 8086 LOSS OF CRC MULTIFRAME ALIGNMENT. . . . . . . . . . . . . . . 190

86 8087 LOSS OF OCTET TIMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192

87 8088 END TO END FRAME LOSS . . . . . . . . . . . . . . . . . . . . . . . . . . . 194

88 8089 LOSS OF SIGNALLING FRAME . . . . . . . . . . . . . . . . . . . . . . . . 196

89 8096 EXCESSIVE ERROR RATE. . . . . . . . . . . . . . . . . . . . . . . . . . . . 198

90 8097 BIT ERROR RATIO (BER) > 1E-1 . . . . . . . . . . . . . . . . . . . . . . . 200

91 8098 BIT ERROR RATIO (BER) > 1E-2 . . . . . . . . . . . . . . . . . . . . . . . 202

92 8099 RECEIVED BIT ERROR RATIO (BER) > 1E-3 . . . . . . . . . . . . . 204

93 8100 RECEIVED BIT ERROR RATIO (BER) > 1E-4 . . . . . . . . . . . . . 206

94 8101 RECEIVED BIT ERROR RATIO (BER) > 1E-5 . . . . . . . . . . . . . 208

95 8102 RECEIVED BIT ERROR RATIO (BER) > 1E-6 . . . . . . . . . . . . . 210

96 8103 BIT ERROR RATIO (BER) > 1E-7 . . . . . . . . . . . . . . . . . . . . . . . 212

Page 6: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 6/486

6 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804cd6

Confidential

97 8104 BIT ERROR RATIO (BER) > 1E-8. . . . . . . . . . . . . . . . . . . . . . . . 214

98 8105 BIT ERROR RATIO (BER) > 1E-9. . . . . . . . . . . . . . . . . . . . . . . . 216

99 8106 BIT ERROR RATIO (BER) > 1E-10. . . . . . . . . . . . . . . . . . . . . . . 218

100 8107 BIT ERROR RATIO (BER) > 1E-11. . . . . . . . . . . . . . . . . . . . . . . 220

101 8108 BIT ERROR RATIO (BER) > 1E-12. . . . . . . . . . . . . . . . . . . . . . . 222

102 8109 FADING IN TRANSMISSION PATH . . . . . . . . . . . . . . . . . . . . . . 224

103 8110 SELECTIVE FADING IN TRANSMISSION PATH. . . . . . . . . . . . 226

104 8111 MODULATION ERROR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228

105 8112 FREQUENCY ERROR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230

106 8113 BUFFER OVERFLOW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232

107 8119 SYNCHRONIZING FAULT IN TRANSMITTER . . . . . . . . . . . . . . 234

108 8120 SYNCHRONIZING FAULT IN RECEIVER . . . . . . . . . . . . . . . . . 236

109 8121 SYNCHRONIZING FAULT IN AUXILIARY CHANNEL . . . . . . . . 238

110 8122 SYNCHRONIZING FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240

111 8123 SYNCHRONIZING FAULT IN CARRIER RECOVERY . . . . . . . . 242

112 8124 SYNCHRONIZATION FAULT IN CLOCK RECOVERY. . . . . . . . 244

113 8125 LOSS OF SYNCHRONIZATION SIGNAL . . . . . . . . . . . . . . . . . . 246

114 8126 UNIT FUNCTION DEGRADED . . . . . . . . . . . . . . . . . . . . . . . . . . 248

115 8127 EQUIPMENT FAULT DETECTED IN AUTOMATIC LOOP TEST250

116 8128 FAULT IN EQUIPMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252

117 8129 FAULT IN CODEC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254

118 8130 FAULT IN MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256

119 8131 INTERNAL BUS FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258

120 8132 FAULT IN SUMMING UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260

121 8133 FAULT IN MUX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262

122 8134 EXCHANGE LINE ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264

123 8135 EQUIPMENT IN RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266

124 8136 AIS OSCILLATOR FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268

125 8137 OSCILLATOR FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270

126 8138 PRESSURE ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272

127 8139 SUBRACK HAS MISSING UNITS. . . . . . . . . . . . . . . . . . . . . . . . 274

128 8140 SUBRACK HAS EXCESSIVE UNITS . . . . . . . . . . . . . . . . . . . . . 276

129 8141 FORCED CONTROL ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278

Page 7: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 7/486

DN998797 7

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804cd6

Confidential

130 8142 INSTALLATION ERROR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280

131 8143 FAULT IN CHANGE OVER FUNCTION. . . . . . . . . . . . . . . . . . . 282

132 8144 OPERATING ERROR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284

133 8145 TEMPERATURE ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286

134 8146 WIND ALARM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288

135 8147 LOCAL ALARM CANCEL WITHOUT ANY ALARM . . . . . . . . . . 290

136 8148 EQUIPMENT RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292

137 8149 FORCED INDICATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294

138 8150 FAULT IN UNIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296

139 8151 FAULT IN CHANNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298

140 8152 FAULT IN BLOCK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300

141 8153 FAULT IN TRANSMITTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302

142 8154 FAULT IN RECEIVER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304

143 8155 LASER BIAS OUT OF RANGE. . . . . . . . . . . . . . . . . . . . . . . . . . 306

144 8156 LASER POWER OUT OF RANGE . . . . . . . . . . . . . . . . . . . . . . . 308

145 8157 LASER TEMPERATURE OUT OF RANGE . . . . . . . . . . . . . . . . 310

146 8158 FORCED LASER CUT OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312

147 8159 RUN DIAGNOSTICS TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314

148 8160 INTERFACE UNIT FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316

149 8161 CONNECTED TO REDUNDANT SYSTEM . . . . . . . . . . . . . . . . 318

150 8162 DATABASE FULL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320

151 8163 REDUNDANT CONNECTION IN USE . . . . . . . . . . . . . . . . . . . . 322

152 8164 LINE CABLE FAULT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324

153 8165 REAL TIME LOST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326

154 8166 E1 CONVERTER RESET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328

155 8167 E1 CONVERTER FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330

156 8168 EQUIPMENT DOOR OPEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332

157 8169 EXTENDED FAULT CODE IN USE . . . . . . . . . . . . . . . . . . . . . . 334

158 8172 YELLOW ALARM OCCURRED . . . . . . . . . . . . . . . . . . . . . . . . . 336

159 8173 FAR-END ALARM 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338

160 8174 FAR-END ALARM 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340

161 8175 FAR-END ALARM 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342

162 8176 FAR-END ALARM RECEIVED . . . . . . . . . . . . . . . . . . . . . . . . . . 344

Page 8: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 8/486

8 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804cd6

Confidential

163 8178 MULTIFRAME ALARM FROM FAR-END . . . . . . . . . . . . . . . . . . 346

164 8179 FAR-END ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348

165 8180 ALARM FROM FAR-END SUBSYSTEM. . . . . . . . . . . . . . . . . . . 350

166 8181 FAR-END SENDING FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352

167 8182 FAULT IN FAR-END RECEIVING . . . . . . . . . . . . . . . . . . . . . . . . 354

168 8183 FAR-END SYNCHRONIZATION ALARM . . . . . . . . . . . . . . . . . . 356

169 8184 REAL TIME UPDATED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 358

170 8185 CONNECTION OR SETTINGS HAVE CHANGED . . . . . . . . . . . 360

171 8186 CONFIGURATION ERROR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362

172 8190 CUSTOMER SPECIFIC FAULT CODE 1 . . . . . . . . . . . . . . . . . . 364

173 8191 CUSTOMER SPECIFIC FAULT CODE 2 . . . . . . . . . . . . . . . . . . 366

174 8192 CUSTOMER SPECIFIC FAULT CODE 3 . . . . . . . . . . . . . . . . . . 368

175 8193 CUSTOMER SPECIFIC FAULT CODE 4 . . . . . . . . . . . . . . . . . . 370

176 8194 CUSTOMER SPECIFIC FAULT CODE 5 . . . . . . . . . . . . . . . . . . 372

177 8195 V5 PROTOCOL ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374

178 8200 LOSS OF PRIMARY SUPERVISION CONNECTION . . . . . . . . . 376

179 8201 LOSS OF SECONDARY SUPERVISION CONNECTION. . . . . . 378

180 8202 LOSS OF SUPERVISION CONNECTION. . . . . . . . . . . . . . . . . . 380

181 8203 LOSS OF SUPERVISION BUS . . . . . . . . . . . . . . . . . . . . . . . . . . 382

182 8206 CONGESTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384

183 8207 CALIBRATION EXPIRED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 386

184 8213 REMOTE DEFECT INDICATION (RDI). . . . . . . . . . . . . . . . . . . . 388

185 8214 SIGNAL DEGRADED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390

186 8215 TRACE IDENTIFIER MISMATCH . . . . . . . . . . . . . . . . . . . . . . . . 392

187 8216 UNEQUIPPED SIGNAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394

188 8221 VERSION MISMATCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396

189 8222 CORRUPT DATA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 398

190 8223 PROTECTION SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400

191 8230 THRESHOLD CROSSED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402

192 8240 ACTIVE ALARM POINT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 404

193 8241 UPPER ALARM LIMIT EXCEEDED . . . . . . . . . . . . . . . . . . . . . . 406

194 8242 LOWER ALARM LIMIT EXCEEDED . . . . . . . . . . . . . . . . . . . . . . 408

195 8250 INVALID TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410

Page 9: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 9/486

DN998797 9

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804cd6

Confidential

196 8254 OPERATOR DISABLED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412

197 8256 15 MIN G826 ES THRESHOLD CROSSED. . . . . . . . . . . . . . . . 414

198 8257 15 MIN G826 SES THRESHOLD CROSSED . . . . . . . . . . . . . . 416

199 8258 15 MIN G826 BBE THRESHOLD CROSSED . . . . . . . . . . . . . . 418

200 8259 24 H G826 ES THRESHOLD CROSSED. . . . . . . . . . . . . . . . . . 420

201 8260 24 H G826 SES THRESHOLD CROSSED . . . . . . . . . . . . . . . . 422

202 8261 24 H G826 BBE THRESHOLD CROSSED . . . . . . . . . . . . . . . . 424

203 8262 STATISTIC UNAVAILABILITY . . . . . . . . . . . . . . . . . . . . . . . . . . 426

204 8263 STATISTIC RESET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 428

205 8264 15 MIN T/RLTS THRESHOLD CROSSED. . . . . . . . . . . . . . . . . 430

206 8265 24 H T/RLTS THRESHOLD CROSSED. . . . . . . . . . . . . . . . . . . 432

207 8266 LICENCE KEY NOT VALID . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434

208 8267 LICENCE EXPIRED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436

209 8268 LICENCE WILL EXPIRE IN THE NEAR FUTURE . . . . . . . . . . . 438

210 8269 LICENCE FOR FEATURE IS NOT AVAILABLE. . . . . . . . . . . . . 440

211 8270 LICENCE FOR FEATURE HAS BEEN ACTIVATED . . . . . . . . . 442

212 8271 LICENCE FOR FEATURE HAS BEEN DEACTIVATED. . . . . . . 444

213 8272 POSITION NOT LOCKED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446

214 8273 LICENCE FOR 2G FLEXI ABIS OVER IP/ETHERNET IS NOT

 AVAILABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 448

215 8274 LICENCE FOR 2G FLEXI ADDITIONAL 2 E1/T1 IS NOT AVAILABLE

450

216 8275 LICENCE FOR 2G FLEXI ABIS TRS GROOMING IS NOT AVAIL-

 ABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 452

217 8276 LICENCE FOR 2G FLEXI TRS LOOP PROTECTION IS NOT AVAIL-

 ABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454

218 8277 ETHERNET PHYSICAL LINK LAYER LOST . . . . . . . . . . . . . . . 456

219 8278 PSEUDOWIRE DOWN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458

220 8279 PSEUDOWIRE PERFORMANCE DEGRADED. . . . . . . . . . . . . 460

221 8280 PSEUDOWIRE REMOTE PACKET LOSS. . . . . . . . . . . . . . . . . 462

222 8281 FAULT IN OPTICAL INTERFACE (SFP) . . . . . . . . . . . . . . . . . . 464

223 8282 PSEUDOWIRE TUNNEL DOWN . . . . . . . . . . . . . . . . . . . . . . . . 466

224 8283 LICENCE FOR IP SECURITY IS NOT AVAILABLE. . . . . . . . . . 468

225 8284 TRAFFIC SHAPING MISCONFIGURATION . . . . . . . . . . . . . . . 470

226 8285 LICENCE FOR TIMING OVER PACKET IS NOT AVAILABLE . 472

Page 10: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 10/486

10 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804cd6

Confidential

227 8286 LICENCE FOR SYNCHRONOUS ETHERNET IS NOT AVAILABLE

474

228 8287 CLOCK RECOVERY IN PROGRESS . . . . . . . . . . . . . . . . . . . . . 476

229 8288 FAULT IN CONNECTION TO CLOCK MASTER . . . . . . . . . . . . 478

230 8289 SSM HAS LOST TRACEABILITY TO PRC CLOCK SOURCE . . 480

231 8290 LICENCE FOR PACKET TRS E1/T1 IS NOT AVAILABLE . . . . . 482

232 8291 PMTU BTS TO BSC LESS THAN CONFIGRUED MTU . . . . . . . 484

233 8292 PMTU BTS TO SECURITY GATEWAY LESS THAN CONFIGURED

MTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 486

Page 11: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 11/486

DN998797 11

Transmission Equipment Alarms (8000-8999) Summary of changes

Id:0900d80580804c95

Confidential

Summary of changesChanges between document issues are cumulative. Therefore, the latest document

issue contains all changes made to previous issues.

Changes made between issues 8-1 and 8-0

 Alarms 8288 and 8289 have been updated. Notes added to meaning of alarm sections.

Changes made between issues 8-0 and 7-2

New alarms

Modified alarms

Changes made between issues 7-2 and 7-1

The names of the features BSS30305: 2G Flexi Abis over IP/Ethernet, BSS30280: 2GFlexi TRS Loop Protection, BSS21129: Flexi EDGE Abis TRS Grooming, and

BSS30285: 2G Flexi Additional 2 E1,T1 IF have been modified.

Changes made between issues 7-1 and 7-0

Modified alarms

The Flexi EDGE BTS specific instructions of the following alarms have been updated:

 –  8273 LICENCE FOR FLEXIEDGE ABIS OVER IP/ETHERNET IS NOT AVAILABLE

 –  8274 LICENCE FOR FLEXIEDGE ADDITIONAL 2 E1/T1 IS NOT AVAILABLE

 –  8275 LICENCE FOR FLEXIEDGE TRS ABIS GROOMING IS NOT AVAILABLE

 – 8276 LICENCE FOR FLEXIEDGE TRS LOOP PROTECTION IS NOT AVAILABLE

8283 8286 8289 8292

8284 8287 8290

8285 8288 8291

8099 8274 8277 8281

8112 8275 8278 8282

8273 8276 8280

Page 12: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 12/486

12 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

List of Alarms

1 List of Alarms8000 POWER SUPPLY FAULT

8001 TOTAL LOSS OF POWER SUPPLY8002 LOSS OF BACK UP POWER SUPPLY

8003 LOSS OF REMOTE POWER SUPPLY

8004 UNBALANCE IN REMOTE POWER SUPPLY

8005 INCORRECT RINGING VOLTAGE

8006 FAULT IN CENTRAL BATTERY

8007 FAULT IN CRITERIA VOLTAGE

8008 LOW BATTERY VOLTAGE

8009 FAULT IN CURRENT LOOP

8010 SUPPLY UNIT VOLTAGE INCORRECT

8011 DISTRIBUTION FUSE FAULT

8012 SIGNALLING VOLTAGE FAULT

8013 CHARGER FAULT

8014 AC INPUT VOLTAGE FAILURE

8016 MAIN FUNCTION INHIBITED

8017 SIGNAL LOOPED TO TERMINAL

8018 SIGNAL IS LOOPED TO TRANSMISSION PATH

8019 FUNCTION INHIBITED

8020 BLOCKED FROM USE

8021 LOOP TO INTERFACE

8022 LOOP TO EQUIPMENT

8023 TEST MODE

8024 LOOP IN EQUIPMENT

8025 TEST GENERATOR ON

8026 EXTERNAL TEST MODE ACTIVE

8027 BLOCKED FROM FAR END

8028 TIMESLOT RESERVED

8032 LOSS OF OUTGOING SIGNAL

8033 LOSS OF OUTGOING 64K SIGNAL

8034 LOSS OF OUTGOING 2M SIGNAL

8035 LOSS OF OUTGOING 8M SIGNAL

8036 LOSS OF OUTGOING 34M SIGNAL

8037 LOSS OF OUTGOING 140M SIGNAL

8038 LOSS OF OUTGOING 560M SIGNAL

8039 LOSS OF OUTGOING 0.7M SIGNAL

8040 NO FREE CHANNEL

Page 13: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 13/486

DN998797 13

Transmission Equipment Alarms (8000-8999) List of Alarms

Id:0900d80580804c95

Confidential

8042 LOSS OF OUTGOING TRANSMISSION PATH SIGNAL

8043 INCORRECT OUTGOING SIGNAL LEVEL

8044 HIGH REFLECTED POWER

8045 NO OUTGOING SIGNAL

8046 NO OUTGOING LINE SIGNAL

8047 PAYLOAD MISMATCH

8048 LOSS OF INCOMING SIGNAL

8049 LOSS OF INCOMING 64K SIGNAL

8050 LOSS OF INCOMING 2M SIGNAL

8051 LOSS OF INCOMING 8M SIGNAL

8052 LOSS OF INCOMING 34M SIGNAL

8053 LOSS OF INCOMING 140M SIGNAL

8054 LOSS OF INCOMING 560M SIGNAL

8055 LOSS OF INCOMING 0.7M SIGNAL

8056 LOSS OF INCOMING 1.5M SIGNAL

8057 LOSS OF POINTER

8058 LOSS OF INCOMING TRANSMISSION PATH SIGNAL

8059 INCORRECT INCOMING SIGNAL LEVEL

8060 NO INCOMING RADIO SIGNAL

8061 LOSS OF INCOMING LINE SIGNAL

8062 NO CONNECTION8063 NO REDUNDANT CONNECTION

8064 ALARM SIGNAL (AIS) IS RECEIVED

8065 ALARM SIGNAL (AIS 64K) IS RECEIVED

8066 ALARM INDICATION SIGNAL (AIS) RECEIVED

8067 ALARM SIGNAL (AIS 8M) IS RECEIVED

8068 ALARM SIGNAL (AIS 34M) IS RECEIVED

8069 ALARM SIGNAL (AIS 140M) IS RECEIVED

8070 ALARM SIGNAL (AIS 560M) IS RECEIVED

8071 ALARM SIGNAL (AIS 0.7M) IS RECEIVED

8072 ALARM SIGNAL (AIS 16K) IS RECEIVED

8073 ALARM INDICATION SIGNAL (AIS) RECEIVED

8074 ALARM INDICATION SIGNAL RECEIVED ON TIMESLOT 16

8075 S ALARM RECEIVED

8076 GENERAL ALARM IN NETWORK RECEIVED

8077 LOOPED SIGNAL RECEIVED

8078 MEASUREMENT SIGNAL RECEIVED

8079 TS16 CODE ERROR RECEIVED

8080 FRAME ERROR

Page 14: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 14/486

14 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

List of Alarms

8081 LOSS OF FRAME ALIGNMENT

8082 MULTIFRAME ALIGNMENT LOST

8083 LOSS OF FRAME ALIGNMENT OF SUBSYSTEM

8084 LOSS OF LINE FRAME ALIGNMENT

8085 LOSS OF RADIO FRAME ALIGNMENT

8086 LOSS OF CRC MULTIFRAME ALIGNMENT

8087 LOSS OF OCTET TIMING

8088 END TO END FRAME LOSS

8089 LOSS OF SIGNALLING FRAME

8096 EXCESSIVE ERROR RATE

8097 BIT ERROR RATIO (BER) > 1E-1

8098 BIT ERROR RATIO (BER) > 1E-2

8099 RECEIVED BIT ERROR RATIO (BER) > 1E-3

8100 RECEIVED BIT ERROR RATIO (BER) > 1E-4

8101 RECEIVED BIT ERROR RATIO (BER) > 1E-5

8102 RECEIVED BIT ERROR RATIO (BER) > 1E-6

8103 BIT ERROR RATIO (BER) > 1E-7

8104 BIT ERROR RATIO (BER) > 1E-8

8105 BIT ERROR RATIO (BER) > 1E-9

8106 BIT ERROR RATIO (BER) > 1E-10

8107 BIT ERROR RATIO (BER) > 1E-118108 BIT ERROR RATIO (BER) > 1E-12

8109 FADING IN TRANSMISSION PATH

8110 SELECTIVE FADING IN TRANSMISSION PATH

8111 MODULATION ERROR

8112 FREQUENCY ERROR

8113 BUFFER OVERFLOW

8119 SYNCHRONIZING FAULT IN TRANSMITTER

8120 SYNCHRONIZING FAULT IN RECEIVER

8121 SYNCHRONIZING FAULT IN AUXILIARY CHANNEL

8122 SYNCHRONIZING FAULT

8123 SYNCHRONIZING FAULT IN CARRIER RECOVERY

8124 SYNCHRONIZATION FAULT IN CLOCK RECOVERY

8125 LOSS OF SYNCHRONIZATION SIGNAL

8126 UNIT FUNCTION DEGRADED

8127 EQUIPMENT FAULT DETECTED IN AUTOMATIC LOOP TEST

8128 FAULT IN EQUIPMENT

8129 FAULT IN CODEC

8130 FAULT IN MEMORY

Page 15: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 15/486

DN998797 15

Transmission Equipment Alarms (8000-8999) List of Alarms

Id:0900d80580804c95

Confidential

8131 INTERNAL BUS FAULT

8132 FAULT IN SUMMING UNIT

8133 FAULT IN MUX

8134 EXCHANGE LINE ALARM

8135 EQUIPMENT IN RESET

8136 AIS OSCILLATOR FAULT

8137 OSCILLATOR FAULT

8138 PRESSURE ALARM

8139 SUBRACK HAS MISSING UNITS

8140 SUBRACK HAS EXCESSIVE UNITS

8141 FORCED CONTROL ON

8142 INSTALLATION ERROR

8143 FAULT IN CHANGE OVER FUNCTION

8144 OPERATING ERROR

8145 TEMPERATURE ALARM

8146 WIND ALARM

8147 LOCAL ALARM CANCEL WITHOUT ANY ALARM

8148 EQUIPMENT RESET

8149 FORCED INDICATION

8150 FAULT IN UNIT

8151 FAULT IN CHANNEL8152 FAULT IN BLOCK

8153 FAULT IN TRANSMITTER

8154 FAULT IN RECEIVER

8155 LASER BIAS OUT OF RANGE

8156 LASER POWER OUT OF RANGE

8157 LASER TEMPERATURE OUT OF RANGE

8158 FORCED LASER CUT OFF

8159 RUN DIAGNOSTICS TEST

8160 INTERFACE UNIT FAULT

8161 CONNECTED TO REDUNDANT SYSTEM

8162 DATABASE FULL

8163 REDUNDANT CONNECTION IN USE

8164 LINE CABLE FAULT

8165 REAL TIME LOST

8166 E1 CONVERTER RESET

8167 E1 CONVERTER FAULT

8168 EQUIPMENT DOOR OPEN

8169 EXTENDED FAULT CODE IN USE

Page 16: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 16/486

16 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

List of Alarms

8172 YELLOW ALARM OCCURRED

8173 FAR-END ALARM 4

8174 FAR-END ALARM 3

8175 FAR-END ALARM 2

8176 FAR-END ALARM RECEIVED

8178 MULTIFRAME ALARM FROM FAR-END

8179 FAR-END ALARM

8180 ALARM FROM FAR-END SUBSYSTEM

8181 FAR-END SENDING FAULT

8182 FAULT IN FAR-END RECEIVING

8183 FAR-END SYNCHRONIZATION ALARM

8184 REAL TIME UPDATED

8185 CONNECTION OR SETTINGS HAVE CHANGED

8186 CONFIGURATION ERROR

8190 CUSTOMER SPECIFIC FAULT CODE 1

8191 CUSTOMER SPECIFIC FAULT CODE 2

8192 CUSTOMER SPECIFIC FAULT CODE 3

8193 CUSTOMER SPECIFIC FAULT CODE 4

8194 CUSTOMER SPECIFIC FAULT CODE 5

8195 V5 PROTOCOL ALARM

8200 LOSS OF PRIMARY SUPERVISION CONNECTION8201 LOSS OF SECONDARY SUPERVISION CONNECTION

8202 LOSS OF SUPERVISION CONNECTION

8203 LOSS OF SUPERVISION BUS

8206 CONGESTION

8207 CALIBRATION EXPIRED

8213 REMOTE DEFECT INDICATION (RDI)

8214 SIGNAL DEGRADED

8215 TRACE IDENTIFIER MISMATCH

8216 UNEQUIPPED SIGNAL

8221 VERSION MISMATCH

8222 CORRUPT DATA

8223 PROTECTION SWITCH

8230 THRESHOLD CROSSED

8240 ACTIVE ALARM POINT

8241 UPPER ALARM LIMIT EXCEEDED

8242 LOWER ALARM LIMIT EXCEEDED

8250 INVALID TIME

8254 OPERATOR DISABLED

Page 17: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 17/486

DN998797 17

Transmission Equipment Alarms (8000-8999) List of Alarms

Id:0900d80580804c95

Confidential

8256 15 MIN G826 ES THRESHOLD CROSSED

8257 15 MIN G826 SES THRESHOLD CROSSED

8258 15 MIN G826 BBE THRESHOLD CROSSED

8259 24 H G826 ES THRESHOLD CROSSED

8260 24 H G826 SES THRESHOLD CROSSED

8261 24 H G826 BBE THRESHOLD CROSSED

8262 STATISTIC UNAVAILABILITY

8263 STATISTIC RESET

8264 15 MIN T/RLTS THRESHOLD CROSSED

8265 24 H T/RLTS THRESHOLD CROSSED

8266 LICENCE KEY NOT VALID

8267 LICENCE EXPIRED

8268 LICENCE WILL EXPIRE IN THE NEAR FUTURE

8269 LICENCE FOR FEATURE IS NOT AVAILABLE

8270 LICENCE FOR FEATURE HAS BEEN ACTIVATED

8271 LICENCE FOR FEATURE HAS BEEN DEACTIVATED

8272 POSITION NOT LOCKED

8273 LICENCE FOR 2G FLEXI ABIS OVER IP/ETHERNET IS NOT AVAIL-

 ABLE

8274 LICENCE FOR 2G FLEXI ADDITIONAL 2 E1/T1 IS NOT AVAILABLE

8275 LICENCE FOR 2G FLEXI ABIS TRS GROOMING IS NOT AVAILABLE

8276 LICENCE FOR 2G FLEXI TRS LOOP PROTECTION IS NOT AVAIL-

 ABLE

8277 ETHERNET PHYSICAL LINK LAYER LOST

8278 PSEUDOWIRE DOWN

8279 PSEUDOWIRE PERFORMANCE DEGRADED

8280 PSEUDOWIRE REMOTE PACKET LOSS

8281 FAULT IN OPTICAL INTERFACE (SFP)

8282 PSEUDOWIRE TUNNEL DOWN

8283 LICENCE FOR IP SECURITY IS NOT AVAILABLE

8284 TRAFFIC SHAPING MISCONFIGURATION

8285 LICENCE FOR TIMING OVER PACKET IS NOT AVAILABLE

8286 LICENCE FOR SYNCHRONOUS ETHERNET IS NOT AVAILABLE

8287 CLOCK RECOVERY IN PROGRESS

8288 FAULT IN CONNECTION TO CLOCK MASTER

8289 SSM HAS LOST TRACEABILITY TO PRC CLOCK SOURCE

8290 LICENCE FOR PACKET TRS E1/T1 IS NOT AVAILABLE

8291 PMTU BTS TO BSC LESS THAN CONFIGRUED MTU

8292 PMTU BTS TO SECURITY GATEWAY LESS THAN CONFIGUREDMTU

Page 18: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 18/486

18 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

Transmission equipment parameters (DX 200 AlarmSystem)

2 Transmission equipment parameters (DX

200 Alarm System)

ALARM CLS OUT IDL IDD CDL ALV

8000 *** ALARM 1 00:00 00:00 00:00 -

8001 *** ALARM 1 00:00 00:10 00:10 -

8002 *** ALARM 1 00:00 00:10 00:10 -

8003 *** ALARM 1 00:00 00:10 00:10 -

8004 *** ALARM 1 00:00 00:10 00:10 -

8005 *** ALARM 1 00:00 00:10 00:10 -

8006 *** ALARM 1 00:00 00:10 00:10 -

8007 *** ALARM 1 00:00 00:10 00:10 -

8008 *** ALARM 1 00:00 00:10 00:10 -

8009 *** ALARM 1 00:00 00:10 00:10 -

8010 *** ALARM 1 00:00 00:10 00:10 -8011 *** ALARM 1 00:00 00:10 00:10 -

8012 *** ALARM 1 00:00 00:10 00:10 -

8013 ** ALARM 5 00:00 00:10 00:10 -

8014 NOTICE NONE 00:00 00:00 00:00 00:00:15

8016 *** ALARM 1 00:00 00:10 00:10 -

8017 *** ALARM 1 00:00 00:10 00:10 -

8018 *** ALARM 1 00:00 00:10 00:10 -

8019 *** ALARM 1 00:00 00:10 00:10 -

8020 ** ALARM 5 00:00 00:10 00:10 -

8021 ** ALARM 5 00:00 00:10 00:10 -

8022 ** ALARM 5 00:00 00:10 00:10 -

8023 ** ALARM 5 00:00 00:10 00:10 -

8024 *** ALARM 1 00:00 00:10 00:10 -

8025 ** ALARM 5 00:00 00:10 00:10 -

8026 ** ALARM 5 00:00 00:10 00:10 -

8027 ** ALARM 5 00:00 00:10 00:10 -

8028 ** ALARM 5 00:00 00:10 00:10 -

8032 *** ALARM 1 00:00 00:10 00:10 -

8033 *** ALARM 1 00:00 00:10 00:10 -

8034 *** ALARM 1 00:00 00:10 00:10 -

8035 *** ALARM 1 00:00 00:10 00:10 -

8036 *** ALARM 1 00:00 00:10 00:10 -

8037 *** ALARM 1 00:00 00:10 00:10 -8038 *** ALARM 1 00:00 00:10 00:10 -

8039 *** ALARM 1 00:00 00:10 00:10 -

8040 DISTUR NONE 00:00 00:00 00:00 00:00:15

8042 *** ALARM 1 00:00 00:10 00:10 -

8043 *** ALARM 1 00:00 00:10 00:10 -

8044 *** ALARM 1 00:00 00:10 00:10 -

8045 *** ALARM 1 00:00 00:10 00:10 -

8046 *** ALARM 1 00:00 00:10 00:10 -

8047 *** ALARM 1 00:00 00:10 00:10 -

8048 *** ALARM 1 00:00 00:10 00:10 -

8049 *** ALARM 1 00:00 00:10 00:10 -

8050 *** ALARM 1 00:00 00:10 00:10 -

Page 19: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 19/486

DN998797 19

Transmission Equipment Alarms (8000-8999) Transmission equipment parameters (DX 200 AlarmSystem)

Id:0900d80580804c95

Confidential

8051 *** ALARM 1 00:00 00:10 00:10 -

8052 *** ALARM 1 00:00 00:10 00:10 -

8053 *** ALARM 1 00:00 00:10 00:10 -

8054 *** ALARM 1 00:00 00:10 00:10 -

8055 *** ALARM 1 00:00 00:10 00:10 -

8056 *** ALARM 1 00:00 00:10 00:10 -

8057 *** ALARM 1 00:00 00:10 00:10 -

8058 *** ALARM 1 00:00 00:10 00:10 -

8059 *** ALARM 1 00:00 00:10 00:10 -

8060 *** ALARM 1 00:00 00:10 00:10 -

8061 *** ALARM 1 00:00 00:10 00:10 -

8062 *** ALARM 1 00:00 00:10 00:10 -

8063 *** ALARM 1 00:00 00:10 00:10 -

8064 ** ALARM 5 00:00 00:10 00:10 -

8065 ** ALARM 5 00:00 00:10 00:10 -

8066 ** ALARM 5 00:00 00:10 00:10 -8067 ** ALARM 5 00:00 00:10 00:10 -

8068 ** ALARM 5 00:00 00:10 00:10 -

8069 ** ALARM 5 00:00 00:10 00:10 -

8070 ** ALARM 5 00:00 00:10 00:10 -

8071 ** ALARM 5 00:00 00:10 00:10 -

8072 ** ALARM 5 00:00 00:10 00:10 -

8073 ** ALARM 5 00:00 00:10 00:10 -

8074 ** ALARM 5 00:00 00:10 00:10 -

8075 ** ALARM 5 00:00 00:10 00:10 -

8076 ** ALARM 5 00:00 00:10 00:10 -

8077 ** ALARM 5 00:00 00:10 00:10 -

8078 ** ALARM 5 00:00 00:10 00:10 -

8079 ** ALARM 5 00:00 00:10 00:10 -

8080 *** ALARM 1 00:00 00:10 00:10 -

8081 *** ALARM 1 00:00 00:10 00:10 -

8082 *** ALARM 1 00:00 00:10 00:10 -

8083 *** ALARM 1 00:00 00:10 00:10 -

8084 *** ALARM 1 00:00 00:10 00:10 -

8085 *** ALARM 1 00:00 00:10 00:10 -

8086 *** ALARM 1 00:00 00:10 00:10 -

8087 *** ALARM 1 00:00 00:10 00:10 -

8088 *** ALARM 1 00:00 00:10 00:10 -

8089 *** ALARM 1 00:00 00:10 00:10 -

8096 *** ALARM 1 00:00 00:10 00:10 -

8097 *** ALARM 1 00:00 00:10 00:10 -

8098 *** ALARM 1 00:00 00:10 00:10 -

8099 *** ALARM 1 00:00 00:15 00:10 -

8100 ** ALARM 5 00:00 00:10 00:10 -

8101 ** ALARM 5 00:00 00:10 00:10 -

8102 ** ALARM 5 00:00 00:30 00:40 -

8103 * ALARM NONE 00:00 00:10 00:10 -

8104 * ALARM NONE 00:00 00:10 00:10 -

8105 * ALARM NONE 00:00 00:10 00:10 -

8106 * ALARM NONE 00:00 00:10 00:10 -8107 * ALARM NONE 00:00 00:10 00:10 -

Page 20: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 20/486

20 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

Transmission equipment parameters (DX 200 AlarmSystem)

8108 * ALARM NONE 00:00 00:10 00:10 -

8109 ** ALARM 5 00:00 00:10 00:10 -

8110 ** ALARM 5 00:00 00:10 00:10 -

8111 *** ALARM 1 00:00 00:10 00:10 -

8112 * ALARM NONE 00:00 00:10 00:10 -

8113 * ALARM NONE 00:00 00:10 00:10 -

8119 ** ALARM 5 00:00 00:10 00:10 -

8120 ** ALARM 5 00:00 00:10 00:10 -

8121 ** ALARM 5 00:00 00:10 00:10 -

8122 ** ALARM 5 00:00 00:10 00:10 -

8123 ** ALARM 5 00:00 00:10 00:10 -

8124 ** ALARM 5 00:00 00:10 00:10 -

8125 *** ALARM 1 00:00 00:10 00:10 -

8126 ** ALARM 5 00:00 00:10 00:10 -

8127 ** ALARM 5 00:00 00:10 00:10 -

8128 ** ALARM 5 00:00 00:10 00:10 -8129 ** ALARM 5 00:00 00:10 00:10 -

8130 ** ALARM 5 00:00 00:10 00:10 -

8131 ** ALARM 5 00:00 00:10 00:10 -

8132 ** ALARM 5 00:00 00:10 00:10 -

8133 ** ALARM 5 00:00 00:10 00:10 -

8134 ** ALARM 5 00:00 00:10 00:10 -

8135 ** ALARM 5 00:00 00:10 00:10 -

8136 ** ALARM 5 00:00 00:10 00:10 -

8137 ** ALARM 5 00:00 00:10 00:10 -

8138 ** ALARM 5 00:00 00:10 00:10 -

8139 *** ALARM 1 00:00 00:10 00:10 -

8140 ** ALARM 5 00:00 00:10 00:10 -

8141 *** ALARM 1 00:00 00:10 00:10 -

8142 *** ALARM 1 00:00 00:10 00:10 -

8143 *** ALARM 1 00:00 00:10 00:10 -

8144 *** ALARM 1 00:00 00:10 00:10 -

8145 ** ALARM 5 00:00 00:10 00:10 -

8146 ** ALARM 5 00:00 00:10 00:10 -

8147 NOTICE NONE 00:00 00:00 00:00 00:00:15

8148 NOTICE NONE 00:00 00:00 00:00 00:00:15

8149 NOTICE NONE 00:00 00:00 00:00 00:00:15

8150 *** ALARM 1 00:00 00:10 00:10 -

8151 *** ALARM 1 00:00 00:10 00:10 -

8152 *** ALARM 1 00:00 00:10 00:10 -

8153 *** ALARM 1 00:00 00:10 00:10 -

8154 *** ALARM 1 00:00 00:10 00:10 -

8155 *** ALARM 1 00:00 00:10 00:10 -

8156 *** ALARM 1 00:00 00:10 00:10 -

8157 *** ALARM 1 00:00 00:10 00:10 -

8158 *** ALARM 1 00:00 00:10 00:10 -

8159 *** ALARM 1 00:00 00:10 00:10 -

8160 *** ALARM 1 00:00 00:10 00:10 -

8161 ** ALARM 5 00:00 00:10 00:10 -

8162 NOTICE NONE 00:00 00:00 00:00 00:00:158163 ** ALARM 5 00:00 00:10 00:10 -

Page 21: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 21/486

DN998797 21

Transmission Equipment Alarms (8000-8999) Transmission equipment parameters (DX 200 AlarmSystem)

Id:0900d80580804c95

Confidential

8164 *** ALARM 1 00:00 00:10 00:10 -

8165 ** ALARM 5 00:00 00:10 00:10 -

8166 ** ALARM 5 00:00 00:10 00:10 -

8167 *** ALARM 1 00:00 00:10 00:10 -

8168 * ALARM NONE 00:00 00:10 00:10 -

8169 * ALARM NONE 00:00 00:10 00:10 -

8172 ** ALARM 5 00:00 00:10 00:10 -

8173 DISTUR NONE 00:00 00:00 00:00 00:00:15

8174 * ALARM NONE 00:00 00:10 00:10 -

8175 ** ALARM 5 00:00 00:10 00:10 -

8176 *** ALARM 1 00:00 00:10 00:10 -

8178 ** ALARM 5 00:00 00:10 00:10 -

8179 ** ALARM 5 00:00 00:10 00:10 -

8180 ** ALARM 5 00:00 00:10 00:10 -

8181 ** ALARM 5 00:00 00:10 00:10 -

8182 ** ALARM 5 00:00 00:10 00:10 -8183 ** ALARM 5 00:00 00:10 00:10 -

8184 NOTICE NONE 00:00 00:00 00:00 00:00:15

8185 DISTUR NONE 00:00 00:00 00:00 00:00:15

8186 * ALARM NONE 00:00 00:00 00:00 -

8190 * ALARM NONE 00:00 00:00 00:00 -

8191 * ALARM NONE 00:00 00:00 00:00 -

8192 * ALARM NONE 00:00 00:00 00:00 -

8193 ** ALARM 5 00:00 00:00 00:00 -

8194 ** ALARM 5 00:00 00:00 00:00 -

8195 *** ALARM 1 00:00 00:00 00:00 -

8200 ** ALARM 5 00:00 00:00 00:00 -

8201 ** ALARM 5 00:00 00:00 00:00 -

8202 *** ALARM 1 00:00 00:00 00:00 -

8203 *** ALARM 1 00:00 00:00 00:00 -

8206 DISTUR NONE 00:00 00:00 00:00 00:00:15

8207 DISTUR NONE 00:00 00:00 00:00 00:00:15

8213 ** ALARM 5 00:00 00:00 00:00 -

8214 ** ALARM 5 00:00 00:00 00:00 -

8215 *** ALARM 1 00:00 00:00 00:00 -

8216 *** ALARM 1 00:00 00:00 00:00 -

8221 *** ALARM 1 00:00 00:00 00:00 -

8222 *** ALARM 1 00:00 00:00 00:00 -

8223 DISTUR NONE 00:00 00:00 00:00 00:00:15

8230 NOTICE NONE 00:00 00:00 00:00 00:00:15

8240 ** ALARM 5 00:00 00:00 00:00 -

8241 *** ALARM 1 00:00 00:00 00:00 -

8242 * ALARM NONE 00:00 00:00 00:00 -

8250 * ALARM NONE 00:00 00:00 00:00 -

8254 NOTICE NONE 00:00 00:00 00:00 00:00:15

8256 * ALARM NONE 00:00 00:00 00:00 -

8257 ** ALARM 5 00:00 00:00 00:00 -

8258 * ALARM NONE 00:00 00:00 00:00 -

8259 NOTICE NONE 00:00 00:00 00:00 00:00:15

8260 NOTICE NONE 00:00 00:00 00:00 00:00:158261 NOTICE NONE 00:00 00:00 00:00 00:00:15

Page 22: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 22/486

22 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

Transmission equipment parameters (DX 200 AlarmSystem)

8262 *** ALARM 1 00:00 00:00 00:00 -

8263 NOTICE NONE 00:00 00:00 00:00 00:00:15

8264 ** ALARM 5 00:00 00:00 00:00 -

8265 NOTICE NONE 00:00 00:00 00:00 00:00:15

8266 *** ALARM 1 00:00 00:00 00:00 -

8267 *** ALARM 1 00:00 00:00 00:00 -

8268 ** ALARM 5 00:00 00:00 00:00 -

8269 *** ALARM 1 00:00 00:00 00:00 -

8270 NOTICE NONE 00:00 00:00 00:00 00:00:15

8271 NOTICE NONE 00:00 00:00 00:00 00:00:15

8272 * ALARM NONE 00:10 00:10 00:10 -

8273 *** ALARM 1 00:10 00:10 00:10 -

8274 *** ALARM 1 00:10 00:10 00:10 -

8275 * ALARM NONE 00:10 00:10 00:10 -

8276 * ALARM NONE 00:10 00:10 00:10 -

8277 *** ALARM 1 00:10 00:10 00:10 -8278 *** ALARM 1 00:10 00:10 00:10 -

8279 ** ALARM 5 00:10 00:10 00:10 -

8280 ** ALARM 5 00:10 00:10 00:10 -

8281 *** ALARM 1 00:10 00:10 00:10 -

8282 ** ALARM 5 00:10 00:10 00:10 -

8283 *** ALARM 1 00:10 00:10 00:10 -

8284 ** ALARM 5 00:10 00:10 00:10 -

8285 ** ALARM 5 00:10 00:10 00:10 -

8286 *** ALARM 1 00:10 00:10 00:10 -

8287 * ALARM NONE 00:10 00:10 00:10 -

8288 ** ALARM 5 00:10 00:10 00:10 -

8289 ** ALARM 5 00:10 00:10 00:10 -

8290 ** ALARM 5 00:10 00:10 00:10 -

8291 ** ALARM 5 00:10 00:10 00:10 -

8292 * ALARM NONE 00:10 00:10 00:10 -

Page 23: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 23/486

DN998797 23

Transmission Equipment Alarms (8000-8999) Transmission equipment parameters (BTS Alarm Sys-tem)

Id:0900d80580804c95

Confidential

3 Transmission equipment parameters (BTS

Alarm System)

NUMBER CLASS RECOVERY PRINTING OMC UPD. IDL CDL STATE

8000 *** ON OFF ON 10 10 UNBLOCKED

8001 *** ON OFF ON 10 10 UNBLOCKED

8002 *** ON OFF ON 10 10 UNBLOCKED

8003 *** ON OFF ON 10 10 UNBLOCKED

8004 *** ON OFF ON 10 10 UNBLOCKED

8005 *** ON OFF ON 10 10 UNBLOCKED

8006 *** ON OFF ON 10 10 UNBLOCKED

8007 *** ON OFF ON 10 10 UNBLOCKED

8008 *** ON OFF ON 10 10 UNBLOCKED

8009 *** ON OFF ON 10 10 UNBLOCKED

8010 *** ON OFF ON 10 10 UNBLOCKED8011 *** ON OFF ON 10 10 UNBLOCKED

8012 *** ON OFF ON 10 10 UNBLOCKED

8013 ** ON OFF ON 10 10 UNBLOCKED

8014 ON OFF ON 10 10 UNBLOCKED

8016 *** ON OFF ON 10 10 UNBLOCKED

8017 *** ON OFF ON 10 10 UNBLOCKED

8018 *** ON OFF ON 10 10 UNBLOCKED

8019 *** ON OFF ON 10 10 UNBLOCKED

8020 ** ON OFF ON 10 10 UNBLOCKED

8021 ** ON OFF ON 10 10 UNBLOCKED

8022 ** ON OFF ON 10 10 UNBLOCKED

8023 ** ON OFF ON 10 10 UNBLOCKED

8024 *** ON OFF ON 10 10 UNBLOCKED

8025 ** ON OFF ON 10 10 UNBLOCKED

8026 ** ON OFF ON 10 10 UNBLOCKED

8027 ** ON OFF ON 10 10 UNBLOCKED

8028 ** ON OFF ON 10 10 UNBLOCKED

8032 *** ON OFF ON 10 10 UNBLOCKED

8033 *** ON OFF ON 10 10 UNBLOCKED

8034 *** ON OFF ON 10 10 UNBLOCKED

8035 *** ON OFF ON 10 10 UNBLOCKED

8036 *** ON OFF ON 10 10 UNBLOCKED

8037 *** ON OFF ON 10 10 UNBLOCKED8038 *** ON OFF ON 10 10 UNBLOCKED

8039 *** ON OFF ON 10 10 UNBLOCKED

8040 ON OFF ON 10 10 UNBLOCKED

8042 *** ON OFF ON 10 10 UNBLOCKED

8043 *** ON OFF ON 10 10 UNBLOCKED

8044 *** ON OFF ON 10 10 UNBLOCKED

8045 *** ON OFF ON 10 10 UNBLOCKED

8046 *** ON OFF ON 10 10 UNBLOCKED

8047 *** ON OFF ON 10 10 UNBLOCKED

8048 *** ON OFF ON 10 10 UNBLOCKED

8049 *** ON OFF ON 10 10 UNBLOCKED

8050 *** ON OFF ON 10 10 UNBLOCKED

Page 24: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 24/486

24 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

Transmission equipment parameters (BTS Alarm Sys-tem)

8051 *** ON OFF ON 10 10 UNBLOCKED

8052 *** ON OFF ON 10 10 UNBLOCKED

8053 *** ON OFF ON 10 10 UNBLOCKED

8054 *** ON OFF ON 10 10 UNBLOCKED

8055 *** ON OFF ON 10 10 UNBLOCKED

8056 *** ON OFF ON 10 10 UNBLOCKED

8057 *** ON OFF ON 10 10 UNBLOCKED

8058 *** ON OFF ON 10 10 UNBLOCKED

8059 *** ON OFF ON 10 10 UNBLOCKED

8060 *** ON OFF ON 10 10 UNBLOCKED

8061 *** ON OFF ON 10 10 UNBLOCKED

8062 *** ON OFF ON 10 10 UNBLOCKED

8063 *** ON OFF ON 10 10 UNBLOCKED

8064 ** ON OFF ON 10 10 UNBLOCKED

8065 ** ON OFF ON 10 10 UNBLOCKED

8066 ** ON OFF ON 10 10 UNBLOCKED8067 ** ON OFF ON 10 10 UNBLOCKED

8068 ** ON OFF ON 10 10 UNBLOCKED

8069 ** ON OFF ON 10 10 UNBLOCKED

8070 ** ON OFF ON 10 10 UNBLOCKED

8071 ** ON OFF ON 10 10 UNBLOCKED

8072 ** ON OFF ON 10 10 UNBLOCKED

8073 ** ON OFF ON 10 10 UNBLOCKED

8074 ** ON OFF ON 10 10 UNBLOCKED

8075 ** ON OFF ON 10 10 UNBLOCKED

8076 ** ON OFF ON 10 10 UNBLOCKED

8077 ** ON OFF ON 10 10 UNBLOCKED

8078 ** ON OFF ON 10 10 UNBLOCKED

8079 ** ON OFF ON 10 10 UNBLOCKED

8080 *** ON OFF ON 10 10 UNBLOCKED

8081 *** ON OFF ON 10 10 UNBLOCKED

8082 *** ON OFF ON 10 10 UNBLOCKED

8083 *** ON OFF ON 10 10 UNBLOCKED

8084 *** ON OFF ON 10 10 UNBLOCKED

8085 *** ON OFF ON 10 10 UNBLOCKED

8086 *** ON OFF ON 10 10 UNBLOCKED

8087 *** ON OFF ON 10 10 UNBLOCKED

8088 *** ON OFF ON 10 10 UNBLOCKED

8089 *** ON OFF ON 10 10 UNBLOCKED

8096 *** ON OFF ON 10 10 UNBLOCKED

8097 *** ON OFF ON 10 10 UNBLOCKED

8098 *** ON OFF ON 10 10 UNBLOCKED

8099 *** ON OFF ON 15 10 UNBLOCKED

8100 ** ON OFF ON 10 10 UNBLOCKED

8101 ** ON OFF ON 10 10 UNBLOCKED

8102 ** ON OFF ON 30 40 UNBLOCKED

8103 * ON OFF ON 10 10 UNBLOCKED

8104 * ON OFF ON 10 10 UNBLOCKED

8105 * ON OFF ON 10 10 UNBLOCKED

8106 * ON OFF ON 10 10 UNBLOCKED8107 * ON OFF ON 10 10 UNBLOCKED

Page 25: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 25/486

DN998797 25

Transmission Equipment Alarms (8000-8999) Transmission equipment parameters (BTS Alarm Sys-tem)

Id:0900d80580804c95

Confidential

8108 * ON OFF ON 10 10 UNBLOCKED

8109 ** ON OFF ON 10 10 UNBLOCKED

8110 ** ON OFF ON 10 10 UNBLOCKED

8111 *** ON OFF ON 10 10 UNBLOCKED

8112 * ON OFF ON 10 10 UNBLOCKED

8113 * ON OFF ON 10 10 UNBLOCKED

8119 ** ON OFF ON 10 10 UNBLOCKED

8120 ** ON OFF ON 10 10 UNBLOCKED

8121 ** ON OFF ON 10 10 UNBLOCKED

8122 ** ON OFF ON 10 10 UNBLOCKED

8123 ** ON OFF ON 10 10 UNBLOCKED

8124 ** ON OFF ON 10 10 UNBLOCKED

8125 *** ON OFF ON 10 10 UNBLOCKED

8126 ** ON OFF ON 10 10 UNBLOCKED

8127 ** ON OFF ON 10 10 UNBLOCKED

8128 ** ON OFF ON 10 10 UNBLOCKED8129 ** ON OFF ON 10 10 UNBLOCKED

8130 ** ON OFF ON 10 10 UNBLOCKED

8131 ** ON OFF ON 10 10 UNBLOCKED

8132 ** ON OFF ON 10 10 UNBLOCKED

8133 ** ON OFF ON 10 10 UNBLOCKED

8134 ** ON OFF ON 10 10 UNBLOCKED

8135 ** ON OFF ON 10 10 UNBLOCKED

8136 ** ON OFF ON 10 10 UNBLOCKED

8137 ** ON OFF ON 10 10 UNBLOCKED

8138 ** ON OFF ON 10 10 UNBLOCKED

8139 *** ON OFF ON 10 10 UNBLOCKED

8140 ** ON OFF ON 10 10 UNBLOCKED

8141 *** ON OFF ON 10 10 UNBLOCKED

8142 *** ON OFF ON 10 10 UNBLOCKED

8143 *** ON OFF ON 10 10 UNBLOCKED

8144 *** ON OFF ON 10 10 UNBLOCKED

8145 ** ON OFF ON 10 10 UNBLOCKED

8146 ** ON OFF ON 10 10 UNBLOCKED

8147 ON OFF ON 10 10 UNBLOCKED

8148 ON OFF ON 10 10 UNBLOCKED

8149 ON OFF ON 10 10 UNBLOCKED

8150 *** ON OFF ON 10 10 UNBLOCKED

8151 *** ON OFF ON 10 10 UNBLOCKED

8152 *** ON OFF ON 10 10 UNBLOCKED

8153 *** ON OFF ON 10 10 UNBLOCKED

8154 *** ON OFF ON 10 10 UNBLOCKED

8155 *** ON OFF ON 10 10 UNBLOCKED

8156 *** ON OFF ON 10 10 UNBLOCKED

8157 *** ON OFF ON 10 10 UNBLOCKED

8158 *** ON OFF ON 10 10 UNBLOCKED

8159 *** ON OFF ON 10 10 UNBLOCKED

8160 *** ON OFF ON 10 10 UNBLOCKED

8161 ** ON OFF ON 10 10 UNBLOCKED

8162 ON OFF ON 10 10 UNBLOCKED8163 ** ON OFF ON 10 10 UNBLOCKED

Page 26: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 26/486

26 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

Transmission equipment parameters (BTS Alarm Sys-tem)

8164 *** ON OFF ON 10 10 UNBLOCKED

8165 ** ON OFF ON 10 10 UNBLOCKED

8166 ** ON OFF ON 10 10 UNBLOCKED

8167 *** ON OFF ON 10 10 UNBLOCKED

8168 * ON OFF ON 10 10 UNBLOCKED

8169 * ON OFF ON 10 10 UNBLOCKED

8172 ** ON OFF ON 10 10 UNBLOCKED

8173 ON OFF ON 10 10 UNBLOCKED

8174 * ON OFF ON 10 10 UNBLOCKED

8175 ** ON OFF ON 10 10 UNBLOCKED

8176 *** ON OFF ON 10 10 UNBLOCKED

8178 ** ON OFF ON 10 10 UNBLOCKED

8179 ** ON OFF ON 10 10 UNBLOCKED

8180 ** ON OFF ON 10 10 UNBLOCKED

8181 ** ON OFF ON 10 10 UNBLOCKED

8182 ** ON OFF ON 10 10 UNBLOCKED8183 ** ON OFF ON 10 10 UNBLOCKED

8184 ON OFF ON 10 10 UNBLOCKED

8185 ON OFF ON 10 10 UNBLOCKED

8186 * ON OFF ON 10 10 UNBLOCKED

8190 * ON OFF ON 10 10 UNBLOCKED

8191 * ON OFF ON 10 10 UNBLOCKED

8192 * ON OFF ON 10 10 UNBLOCKED

8193 ** ON OFF ON 10 10 UNBLOCKED

8194 ** ON OFF ON 10 10 UNBLOCKED

8195 *** ON OFF ON 10 10 UNBLOCKED

8200 ** ON OFF ON 10 10 UNBLOCKED

8201 ** ON OFF ON 10 10 UNBLOCKED

8202 *** ON OFF ON 10 10 UNBLOCKED

8203 *** ON OFF ON 10 10 UNBLOCKED

8206 ON OFF ON 10 10 UNBLOCKED

8207 ON OFF ON 10 10 UNBLOCKED

8213 ** ON OFF ON 10 10 UNBLOCKED

8214 ** ON OFF ON 10 10 UNBLOCKED

8215 *** ON OFF ON 10 10 UNBLOCKED

8216 *** ON OFF ON 10 10 UNBLOCKED

8221 *** ON OFF ON 10 10 UNBLOCKED

8222 *** ON OFF ON 10 10 UNBLOCKED

8223 ON OFF ON 10 10 UNBLOCKED

8230 ON OFF ON 10 10 UNBLOCKED

8240 ** ON OFF ON 10 10 UNBLOCKED

8241 *** ON OFF ON 10 10 UNBLOCKED

8242 * ON OFF ON 10 10 UNBLOCKED

8250 * ON OFF ON 10 10 UNBLOCKED

8254 ON OFF ON 10 10 UNBLOCKED

8256 * ON OFF ON 10 10 UNBLOCKED

8257 ** ON OFF ON 10 10 UNBLOCKED

8258 * ON OFF ON 10 10 UNBLOCKED

8259 ON OFF ON 10 10 UNBLOCKED

8260 ON OFF ON 10 10 UNBLOCKED8261 ON OFF ON 10 10 UNBLOCKED

Page 27: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 27/486

DN998797 27

Transmission Equipment Alarms (8000-8999) Transmission equipment parameters (BTS Alarm Sys-tem)

Id:0900d80580804c95

Confidential

8262 *** ON OFF ON 10 10 UNBLOCKED

8263 ON OFF ON 10 10 UNBLOCKED

8264 ** ON OFF ON 10 10 UNBLOCKED

8265 ON OFF ON 10 10 UNBLOCKED

8266 *** ON OFF ON 0 0 UNBLOCKED

8267 *** ON OFF ON 0 0 UNBLOCKED

8268 ** ON OFF ON 0 0 UNBLOCKED

8269 *** ON OFF ON 0 0 UNBLOCKED

8270 ON OFF ON 10 10 UNBLOCKED

8271 ON OFF ON 10 10 UNBLOCKED

8272 * OFF OFF ON 10 10 UNBLOCKED

8273 *** OFF OFF ON 10 10 UNBLOCKED

8274 *** OFF OFF ON 10 10 UNBLOCKED

8275 * OFF OFF ON 10 10 UNBLOCKED

8276 * OFF OFF ON 10 10 UNBLOCKED

8277 *** OFF OFF ON 10 10 UNBLOCKED8278 *** OFF OFF ON 10 10 UNBLOCKED

8279 ** OFF OFF ON 10 10 UNBLOCKED

8280 ** OFF OFF ON 10 10 UNBLOCKED

8281 *** OFF OFF ON 10 10 UNBLOCKED

8282 *** OFF OFF ON 10 10 UNBLOCKED

8283 *** OFF OFF ON 0 0 UNBLOCKED

8284 ** OFF OFF ON 10 10 UNBLOCKED

8285 ** OFF OFF ON 0 0 UNBLOCKED

8286 ** OFF OFF ON 0 0 UNBLOCKED

8287 * OFF OFF ON 10 10 UNBLOCKED

8288 ** OFF OFF ON 10 10 UNBLOCKED

8289 ** OFF OFF ON 10 10 UNBLOCKED

8290 ** OFF OFF ON 0 0 UNBLOCKED

8291 ** OFF OFF ON 10 10 UNBLOCKED

8292 * OFF OFF ON 10 10 UNBLOCKED

8291 ** OFF OFF ON 10 10 UNBLOCKED

8292 * OFF OFF ON 10 10 UNBLOCKED

Page 28: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 28/486

28 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8000 POWER SUPPLY FAULT

4 8000 POWER SUPPLY FAULT

Meaning

There is a fault in the power supply of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 29: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 29/486

DN998797 29

Transmission Equipment Alarms (8000-8999) 8000 POWER SUPPLY FAULT

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 30: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 30/486

30 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8001 TOTAL LOSS OF POWER SUPPLY

5 8001 TOTAL LOSS OF POWER SUPPLY

Meaning

There is a fault in the power supply of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 31: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 31/486

DN998797 31

Transmission Equipment Alarms (8000-8999) 8001 TOTAL LOSS OF POWER SUPPLY

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 32: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 32/486

32 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8002 LOSS OF BACK UP POWER SUPPLY

6 8002 LOSS OF BACK UP POWER SUPPLY

Meaning

There is a fault in the power supply of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 33: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 33/486

DN998797 33

Transmission Equipment Alarms (8000-8999) 8002 LOSS OF BACK UP POWER SUPPLY

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 34: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 34/486

34 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8003 LOSS OF REMOTE POWER SUPPLY

7 8003 LOSS OF REMOTE POWER SUPPLY

Meaning

There is a fault in the power supply of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 35: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 35/486

DN998797 35

Transmission Equipment Alarms (8000-8999) 8003 LOSS OF REMOTE POWER SUPPLY

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 36: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 36/486

36 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8004 UNBALANCE IN REMOTE POWER SUPPLY

8 8004 UNBALANCE IN REMOTE POWER

SUPPLY

Meaning

There is a fault in the power supply of a piece of transmission

equipment.

This alarm affects the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Page 37: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 37/486

DN998797 37

Transmission Equipment Alarms (8000-8999) 8004 UNBALANCE IN REMOTE POWER SUPPLY

Id:0900d80580804c95

Confidential

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 38: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 38/486

38 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8005 INCORRECT RINGING VOLTAGE

9 8005 INCORRECT RINGING VOLTAGE

Meaning

There is a fault in the power supply of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 39: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 39/486

DN998797 39

Transmission Equipment Alarms (8000-8999) 8005 INCORRECT RINGING VOLTAGE

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 40: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 40/486

40 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8006 FAULT IN CENTRAL BATTERY

10 8006 FAULT IN CENTRAL BATTERY

Meaning

There is a fault in the power supply of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant.

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 41: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 41/486

DN998797 41

Transmission Equipment Alarms (8000-8999) 8006 FAULT IN CENTRAL BATTERY

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 42: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 42/486

42 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8007 FAULT IN CRITERIA VOLTAGE

11 8007 FAULT IN CRITERIA VOLTAGE

Meaning

There is a fault in the power supply of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 43: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 43/486

DN998797 43

Transmission Equipment Alarms (8000-8999) 8007 FAULT IN CRITERIA VOLTAGE

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 44: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 44/486

44 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8008 LOW BATTERY VOLTAGE

12 8008 LOW BATTERY VOLTAGE

Meaning

There is a fault in the power supply of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 45: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 45/486

DN998797 45

Transmission Equipment Alarms (8000-8999) 8008 LOW BATTERY VOLTAGE

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 46: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 46/486

46 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8009 FAULT IN CURRENT LOOP

13 8009 FAULT IN CURRENT LOOP

Meaning

There is a fault in the power supply of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 47: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 47/486

DN998797 47

Transmission Equipment Alarms (8000-8999) 8009 FAULT IN CURRENT LOOP

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 48: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 48/486

48 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8010 SUPPLY UNIT VOLTAGE INCORRECT

14 8010 SUPPLY UNIT VOLTAGE INCORRECT

Meaning

A user operation inhibits the normal use of a piece of transmissionequipment function.

This alarm may affect the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or daughter

  board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 49: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 49/486

DN998797 49

Transmission Equipment Alarms (8000-8999) 8010 SUPPLY UNIT VOLTAGE INCORRECT

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 50: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 50/486

50 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8011 DISTRIBUTION FUSE FAULT

15 8011 DISTRIBUTION FUSE FAULT

Meaning

There is a fault in the power supply of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 51: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 51/486

DN998797 51

Transmission Equipment Alarms (8000-8999) 8011 DISTRIBUTION FUSE FAULT

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 52: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 52/486

52 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8012 SIGNALLING VOLTAGE FAULT

16 8012 SIGNALLING VOLTAGE FAULT

Meaning

There is a fault in the power supply of a piece of transmissionequipment power supply.

This alarm affects the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a daughter

  board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 53: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 53/486

DN998797 53

Transmission Equipment Alarms (8000-8999) 8012 SIGNALLING VOLTAGE FAULT

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 54: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 54/486

54 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8013 CHARGER FAULT

17 8013 CHARGER FAULT

Meaning

There is a fault in the power supply of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 55: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 55/486

DN998797 55

Transmission Equipment Alarms (8000-8999) 8013 CHARGER FAULT

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 56: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 56/486

56 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8014 AC INPUT VOLTAGE FAILURE

18 8014 AC INPUT VOLTAGE FAILURE

Meaning

There is a fault in the power supply of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 57: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 57/486

DN998797 57

Transmission Equipment Alarms (8000-8999) 8014 AC INPUT VOLTAGE FAILURE

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 58: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 58/486

58 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8016 MAIN FUNCTION INHIBITED

19 8016 MAIN FUNCTION INHIBITED

Meaning

A user operation inhibits the normal use of a piece of transmissionequipment function.

This alarm may affect the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 59: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 59/486

DN998797 59

Transmission Equipment Alarms (8000-8999) 8016 MAIN FUNCTION INHIBITED

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 60: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 60/486

60 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8017 SIGNAL LOOPED TO TERMINAL

20 8017 SIGNAL LOOPED TO TERMINAL

Meaning

A user operation inhibits the normal use of a piece of transmissionequipment function.

This alarm may affect the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 61: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 61/486

DN998797 61

Transmission Equipment Alarms (8000-8999) 8017 SIGNAL LOOPED TO TERMINAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 62: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 62/486

62 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8018 SIGNAL IS LOOPED TO TRANSMISSION PATH

21 8018 SIGNAL IS LOOPED TO TRANSMISSION

PATH

Meaning

A user operation inhibits the normal use of a piece of transmission

equipment function.

This alarm may affect the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Page 63: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 63/486

DN998797 63

Transmission Equipment Alarms (8000-8999) 8018 SIGNAL IS LOOPED TO TRANSMISSION PATH

Id:0900d80580804c95

Confidential

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 64: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 64/486

64 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8019 FUNCTION INHIBITED

22 8019 FUNCTION INHIBITED

Meaning

A user operation inhibits the normal use of a piece of transmissionequipment function.

This alarm may affect the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 65: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 65/486

DN998797 65

Transmission Equipment Alarms (8000-8999) 8019 FUNCTION INHIBITED

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 66: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 66/486

66 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8020 BLOCKED FROM USE

23 8020 BLOCKED FROM USE

Meaning

A user operation inhibits the normal use of a piece of transmissionequipment function.

This alarm may affect the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 67: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 67/486

DN998797 67

Transmission Equipment Alarms (8000-8999) 8020 BLOCKED FROM USE

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Description: A cross-connection is configured to an interface which

is not in use.

Instructions:

  1. Check that all interfaces where cross connection termination

  points have been set are in use. In cross connection window,

  blocked cross connections are highlighted in Italic font.

  2. Remove any unnecessary cross connections that have

  termination point(s) to non-existing or unused interfaces.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 68: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 68/486

68 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8021 LOOP TO INTERFACE

24 8021 LOOP TO INTERFACE

Meaning

A user operation inhibits the normal use of a piece of transmissionequipment function.

This alarm may affect the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 69: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 69/486

DN998797 69

Transmission Equipment Alarms (8000-8999) 8021 LOOP TO INTERFACE

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

FLEXI EDGE:

Description: PDH test-loop to Interface activated.

Instructions:

  No actions required, alarm is cancelled when interface loop is

  deactivated by the user with BTS Manager or after defined

  timeout.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 70: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 70/486

70 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8022 LOOP TO EQUIPMENT

25 8022 LOOP TO EQUIPMENT

Meaning

A user operation inhibits the normal use of a piece of transmissionequipment function.

This alarm may affect the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 71: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 71/486

DN998797 71

Transmission Equipment Alarms (8000-8999) 8022 LOOP TO EQUIPMENT

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

FLEXI EDGE:

Description: PDH test-loop to Equipment activated.

Instructions:

  No actions required, alarm is cancelled when interface loop is

  deactivated by the user with BTS Manager or after defined

  timeout.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 72: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 72/486

72 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8023 TEST MODE

26 8023 TEST MODE

Meaning

A user operation inhibits the normal use of a piece of transmissionequipment function.

This alarm may affect the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 73: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 73/486

DN998797 73

Transmission Equipment Alarms (8000-8999) 8023 TEST MODE

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 74: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 74/486

74 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8024 LOOP IN EQUIPMENT

27 8024 LOOP IN EQUIPMENT

Meaning

A user operation inhibits the normal use of a piece of transmissionequipment function.

This alarm may affect the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 75: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 75/486

DN998797 75

Transmission Equipment Alarms (8000-8999) 8024 LOOP IN EQUIPMENT

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 76: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 76/486

76 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8025 TEST GENERATOR ON

28 8025 TEST GENERATOR ON

Meaning

A user operation inhibits the normal use of a piece of transmissionequipment function.

This alarm may affect the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 77: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 77/486

DN998797 77

Transmission Equipment Alarms (8000-8999) 8025 TEST GENERATOR ON

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 78: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 78/486

78 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8026 EXTERNAL TEST MODE ACTIVE

29 8026 EXTERNAL TEST MODE ACTIVE

Meaning

A user operation inhibits the normal use of a piece of transmissionequipment function.

This alarm may affect the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 79: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 79/486

DN998797 79

Transmission Equipment Alarms (8000-8999) 8026 EXTERNAL TEST MODE ACTIVE

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 80: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 80/486

80 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8027 BLOCKED FROM FAR END

30 8027 BLOCKED FROM FAR END

Meaning

A user operation inhibits the normal use of a piece of transmissionequipment function.

This alarm may affect the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 81: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 81/486

DN998797 81

Transmission Equipment Alarms (8000-8999) 8027 BLOCKED FROM FAR END

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 82: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 82/486

82 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8028 TIMESLOT RESERVED

31 8028 TIMESLOT RESERVED

Meaning

A user operation inhibits the normal use of a piece of transmissionequipment function.

This alarm may affect the provided services. The unit is not working

properly and the unit services can be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 83: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 83/486

DN998797 83

Transmission Equipment Alarms (8000-8999) 8028 TIMESLOT RESERVED

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 84: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 84/486

84 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8032 LOSS OF OUTGOING SIGNAL

32 8032 LOSS OF OUTGOING SIGNAL

Meaning

There is a fault in the outgoing signal of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 85: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 85/486

DN998797 85

Transmission Equipment Alarms (8000-8999) 8032 LOSS OF OUTGOING SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 86: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 86/486

86 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8033 LOSS OF OUTGOING 64K SIGNAL

33 8033 LOSS OF OUTGOING 64K SIGNAL

Meaning

There is a fault in the outgoing signal of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 87: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 87/486

DN998797 87

Transmission Equipment Alarms (8000-8999) 8033 LOSS OF OUTGOING 64K SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 88: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 88/486

88 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8034 LOSS OF OUTGOING 2M SIGNAL

34 8034 LOSS OF OUTGOING 2M SIGNAL

Meaning

There is a fault in the outgoing signal of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 89: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 89/486

DN998797 89

Transmission Equipment Alarms (8000-8999) 8034 LOSS OF OUTGOING 2M SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 90: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 90/486

90 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8035 LOSS OF OUTGOING 8M SIGNAL

35 8035 LOSS OF OUTGOING 8M SIGNAL

Meaning

There is a fault in the outgoing signal of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 91: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 91/486

DN998797 91

Transmission Equipment Alarms (8000-8999) 8035 LOSS OF OUTGOING 8M SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 92: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 92/486

92 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8036 LOSS OF OUTGOING 34M SIGNAL

36 8036 LOSS OF OUTGOING 34M SIGNAL

Meaning

There is a fault in the outgoing signal of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 93: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 93/486

DN998797 93

Transmission Equipment Alarms (8000-8999) 8036 LOSS OF OUTGOING 34M SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 94: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 94/486

94 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8037 LOSS OF OUTGOING 140M SIGNAL

37 8037 LOSS OF OUTGOING 140M SIGNAL

Meaning

There is a fault in the outgoing signal of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 95: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 95/486

DN998797 95

Transmission Equipment Alarms (8000-8999) 8037 LOSS OF OUTGOING 140M SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 96: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 96/486

96 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8038 LOSS OF OUTGOING 560M SIGNAL

38 8038 LOSS OF OUTGOING 560M SIGNAL

Meaning

There is a fault in the outgoing signal of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 97: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 97/486

DN998797 97

Transmission Equipment Alarms (8000-8999) 8038 LOSS OF OUTGOING 560M SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 98: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 98/486

98 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8039 LOSS OF OUTGOING 0.7M SIGNAL

39 8039 LOSS OF OUTGOING 0.7M SIGNAL

Meaning

There is a fault in the outgoing signal of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 99: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 99/486

DN998797 99

Transmission Equipment Alarms (8000-8999) 8039 LOSS OF OUTGOING 0.7M SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 100: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 100/486

100 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8040 NO FREE CHANNEL

40 8040 NO FREE CHANNEL

Meaning

There is no available channel for connection, the channel is not freeor the channel cannot be taken in use.

This alarm affects the provided services. The unit is not working

properly and the unit services may be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If the equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 101: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 101/486

DN998797 101

Transmission Equipment Alarms (8000-8999) 8040 NO FREE CHANNEL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 102: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 102/486

102 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8042 LOSS OF OUTGOING TRANSMISSION PATHSIGNAL

41 8042 LOSS OF OUTGOING TRANSMISSION

PATH SIGNAL

Meaning

There is a fault in the outgoing signal of a piece of transmission

equipment.

This alarm affects the provided services. The unit is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Page 103: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 103/486

DN998797 103

Transmission Equipment Alarms (8000-8999) 8042 LOSS OF OUTGOING TRANSMISSION PATHSIGNAL

Id:0900d80580804c95

Confidential

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 104: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 104/486

104 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8043 INCORRECT OUTGOING SIGNAL LEVEL

42 8043 INCORRECT OUTGOING SIGNAL

LEVEL

Meaning

There is a fault in the outgoing signal of a piece of transmission

equipment.

This alarm affects the provided services. The unit is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Page 105: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 105/486

DN998797 105

Transmission Equipment Alarms (8000-8999) 8043 INCORRECT OUTGOING SIGNAL LEVEL

Id:0900d80580804c95

Confidential

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 106: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 106/486

106 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8044 HIGH REFLECTED POWER

43 8044 HIGH REFLECTED POWER

Meaning

There is a fault in the outgoing signal of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 107: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 107/486

DN998797 107

Transmission Equipment Alarms (8000-8999) 8044 HIGH REFLECTED POWER

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 108: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 108/486

108 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8045 NO OUTGOING SIGNAL

44 8045 NO OUTGOING SIGNAL

Meaning

There is a fault in the outgoing signal of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 109: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 109/486

DN998797 109

Transmission Equipment Alarms (8000-8999) 8045 NO OUTGOING SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 110: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 110/486

110 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8046 NO OUTGOING LINE SIGNAL

45 8046 NO OUTGOING LINE SIGNAL

Meaning

There is a fault in the outgoing signal of a piece of transmissionequipment.

This alarm affects the provided services. The unit is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 111: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 111/486

DN998797 111

Transmission Equipment Alarms (8000-8999) 8046 NO OUTGOING LINE SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 112: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 112/486

Page 113: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 113/486

DN998797 113

Transmission Equipment Alarms (8000-8999) 8047 PAYLOAD MISMATCH

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 114: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 114/486

114 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8048 LOSS OF INCOMING SIGNAL

47 8048 LOSS OF INCOMING SIGNAL

Meaning

There is a fault in the incoming signal of a piece of transmissionequipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 115: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 115/486

DN998797 115

Transmission Equipment Alarms (8000-8999) 8048 LOSS OF INCOMING SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Description: External Q1 device does not receive signal at its

interface (e.g. LMU has lost its GPS signal).

Instructions:

  1. Find out the alarming Q1 device and refer to its product

  documentation for more details on this alarm.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 116: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 116/486

116 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8049 LOSS OF INCOMING 64K SIGNAL

48 8049 LOSS OF INCOMING 64K SIGNAL

Meaning

There is a fault in the incoming signal of a piece of transmissionequipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 117: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 117/486

DN998797 117

Transmission Equipment Alarms (8000-8999) 8049 LOSS OF INCOMING 64K SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 118: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 118/486

118 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8050 LOSS OF INCOMING 2M SIGNAL

49 8050 LOSS OF INCOMING 2M SIGNAL

Meaning

There is a fault in the incoming signal of a piece of transmissionequipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 119: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 119/486

DN998797 119

Transmission Equipment Alarms (8000-8999) 8050 LOSS OF INCOMING 2M SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Description: FIxx PIU has detected no incoming signal on E1

interface. Far End Alarm bit indication (TS0/b3) is sent in Tx

direction.

Instructions:

  1. Check that interface settings are the same at both ends of

  the link.

  2. Check that the E1 cable is connected to right interface and

  cable is correctly mated to the PIU. Check the condition of

  cables, connectors and in case FIPA is used, check the

  correct polarities of the wire pairs.

  3. Replace FIxx

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 120: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 120/486

120 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8051 LOSS OF INCOMING 8M SIGNAL

50 8051 LOSS OF INCOMING 8M SIGNAL

Meaning

There is a fault in the incoming signal of a piece of transmissionequipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 121: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 121/486

DN998797 121

Transmission Equipment Alarms (8000-8999) 8051 LOSS OF INCOMING 8M SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 122: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 122/486

122 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8052 LOSS OF INCOMING 34M SIGNAL

51 8052 LOSS OF INCOMING 34M SIGNAL

Meaning

There is a fault in the incoming signal of a piece of transmissionequipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 123: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 123/486

Page 124: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 124/486

124 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8053 LOSS OF INCOMING 140M SIGNAL

52 8053 LOSS OF INCOMING 140M SIGNAL

Meaning

There is a fault in the incoming signal of a piece of transmissionequipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 125: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 125/486

DN998797 125

Transmission Equipment Alarms (8000-8999) 8053 LOSS OF INCOMING 140M SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 126: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 126/486

126 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8054 LOSS OF INCOMING 560M SIGNAL

53 8054 LOSS OF INCOMING 560M SIGNAL

Meaning

There is a fault in the incoming signal of a piece of transmissionequipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 127: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 127/486

DN998797 127

Transmission Equipment Alarms (8000-8999) 8054 LOSS OF INCOMING 560M SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 128: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 128/486

128 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8055 LOSS OF INCOMING 0.7M SIGNAL

54 8055 LOSS OF INCOMING 0.7M SIGNAL

Meaning

There is a fault in the incoming signal of a piece of transmissionequipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 129: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 129/486

Page 130: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 130/486

130 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8056 LOSS OF INCOMING 1.5M SIGNAL

55 8056 LOSS OF INCOMING 1.5M SIGNAL

Meaning

There is a fault in the incoming signal of a piece of transmissionequipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 131: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 131/486

DN998797 131

Transmission Equipment Alarms (8000-8999) 8056 LOSS OF INCOMING 1.5M SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Description: FIxx PIU has detected no incoming signal on T1

interface. Yellow Alarm is sent in Tx direction.

  1. Check that interface settings correspond to the actual link

  characteristics.

  2. Check that the T1 cable is connected to right interface and

  cable is correctly mated to the PIU. Check the condition of

  cables, connectors and correct polarities of the wire pairs.

  3. Replace FIPA.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 132: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 132/486

132 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8057 LOSS OF POINTER

56 8057 LOSS OF POINTER

Meaning

Loss of Pointer condition has occurred.

This alarm affects the provided services. The unit is not working

properly and the unit services may be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If the equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 133: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 133/486

DN998797 133

Transmission Equipment Alarms (8000-8999) 8057 LOSS OF POINTER

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 134: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 134/486

134 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8058 LOSS OF INCOMING TRANSMISSION PATHSIGNAL

57 8058 LOSS OF INCOMING TRANSMISSION

PATH SIGNAL

Meaning

There is a fault in the incoming signal of a piece of transmission

equipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Page 135: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 135/486

DN998797 135

Transmission Equipment Alarms (8000-8999) 8058 LOSS OF INCOMING TRANSMISSION PATHSIGNAL

Id:0900d80580804c95

Confidential

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 136: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 136/486

136 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8059 INCORRECT INCOMING SIGNAL LEVEL

58 8059 INCORRECT INCOMING SIGNAL LEVEL

Meaning

There is a fault in the incoming signal of a piece of transmissionequipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 137: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 137/486

DN998797 137

Transmission Equipment Alarms (8000-8999) 8059 INCORRECT INCOMING SIGNAL LEVEL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 138: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 138/486

138 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8060 NO INCOMING RADIO SIGNAL

59 8060 NO INCOMING RADIO SIGNAL

Meaning

There is a fault in the incoming signal of a piece of transmissionequipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 139: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 139/486

DN998797 139

Transmission Equipment Alarms (8000-8999) 8060 NO INCOMING RADIO SIGNAL

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 140: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 140/486

140 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8061 LOSS OF INCOMING LINE SIGNAL

60 8061 LOSS OF INCOMING LINE SIGNAL

Meaning

There is a fault in the incoming signal of a piece of transmissionequipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 141: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 141/486

Page 142: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 142/486

142 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8062 NO CONNECTION

61 8062 NO CONNECTION

Meaning

There is a fault in the incoming signal of a piece of transmissionequipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 143: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 143/486

DN998797 143

Transmission Equipment Alarms (8000-8999) 8062 NO CONNECTION

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 144: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 144/486

144 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8063 NO REDUNDANT CONNECTION

62 8063 NO REDUNDANT CONNECTION

Meaning

There is a fault in the incoming signal of a piece of transmissionequipment.

This alarm affects the provided services. The interface is not working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 145: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 145/486

DN998797 145

Transmission Equipment Alarms (8000-8999) 8063 NO REDUNDANT CONNECTION

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 146: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 146/486

146 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8064 ALARM SIGNAL (AIS) IS RECEIVED

63 8064 ALARM SIGNAL (AIS) IS RECEIVED

Meaning

A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised

  by a BTS that supports coordin

  ate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Page 147: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 147/486

DN998797 147

Transmission Equipment Alarms (8000-8999) 8064 ALARM SIGNAL (AIS) IS RECEIVED

Id:0900d80580804c95

Confidential

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 148: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 148/486

148 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8065 ALARM SIGNAL (AIS 64K) IS RECEIVED

64 8065 ALARM SIGNAL (AIS 64K) IS RECEIVED

Meaning

A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 149: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 149/486

DN998797 149

Transmission Equipment Alarms (8000-8999) 8065 ALARM SIGNAL (AIS 64K) IS RECEIVED

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 150: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 150/486

Page 151: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 151/486

DN998797 151

Transmission Equipment Alarms (8000-8999) 8066 ALARM INDICATION SIGNAL (AIS) RECEIVED

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Description: The signal is cut, deteriorated or a equipment loop is

set in the far-end equipment. Alarm Indication Signal (AIS) is

indicated as "1111 1111" in all received time slots.

Instructions:

  1. Check the transmission path to find where AIS insertion

  occurs.

  2. Check the alarms at the far-end. Refer to the product

  documentation of the far-end equipment.

  3. In case FIFA PIU is used, check that the microwave link

  is commissioned and operational. Check that 2M cross

  connections are configured at FIFA. Refer to the FIFA

  product documentation for further instructions.

  4. Replace FIxx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically whenthe fault has been corrected.

Page 152: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 152/486

152 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8067 ALARM SIGNAL (AIS 8M) IS RECEIVED

66 8067 ALARM SIGNAL (AIS 8M) IS RECEIVED

Meaning

A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 153: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 153/486

DN998797 153

Transmission Equipment Alarms (8000-8999) 8067 ALARM SIGNAL (AIS 8M) IS RECEIVED

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 154: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 154/486

154 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8068 ALARM SIGNAL (AIS 34M) IS RECEIVED

67 8068 ALARM SIGNAL (AIS 34M) IS RECEIVED

Meaning

A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 155: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 155/486

DN998797 155

Transmission Equipment Alarms (8000-8999) 8068 ALARM SIGNAL (AIS 34M) IS RECEIVED

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 156: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 156/486

156 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8069 ALARM SIGNAL (AIS 140M) IS RECEIVED

68 8069 ALARM SIGNAL (AIS 140M) IS

RECEIVED

Meaning

A piece of transmission equipment receives an alarm signal from another

piece of equipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 157: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 157/486

DN998797 157

Transmission Equipment Alarms (8000-8999) 8069 ALARM SIGNAL (AIS 140M) IS RECEIVED

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 158: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 158/486

Page 159: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 159/486

DN998797 159

Transmission Equipment Alarms (8000-8999) 8070 ALARM SIGNAL (AIS 560M) IS RECEIVED

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 160: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 160/486

160 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8071 ALARM SIGNAL (AIS 0.7M) IS RECEIVED

70 8071 ALARM SIGNAL (AIS 0.7M) IS

RECEIVED

Meaning

A piece of transmission equipment receives an alarm signal from another

piece of equipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 161: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 161/486

DN998797 161

Transmission Equipment Alarms (8000-8999) 8071 ALARM SIGNAL (AIS 0.7M) IS RECEIVED

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 162: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 162/486

162 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8072 ALARM SIGNAL (AIS 16K) IS RECEIVED

71 8072 ALARM SIGNAL (AIS 16K) IS RECEIVED

Meaning

A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 163: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 163/486

Page 164: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 164/486

164 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8073 ALARM INDICATION SIGNAL (AIS) RECEIVED

72 8073 ALARM INDICATION SIGNAL (AIS)

RECEIVED

Meaning

A piece of transmission equipment receives an alarm signal from another

piece of equipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 165: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 165/486

DN998797 165

Transmission Equipment Alarms (8000-8999) 8073 ALARM INDICATION SIGNAL (AIS) RECEIVED

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Description: The signal is cut, deteriorated or a equipment loop is

set in the far-end equipment. Alarm Indication Signal (AIS) is

indicated as "1111 1111" in all received time slots.

Instructions:

  1. Check the transmission path to find where AIS insertion

  occurs.

  2. Check the alarms at the far-end. Refer to the product

  documentation of the far-end equipment.

  3. Replace FIPA.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 166: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 166/486

166 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8074 ALARM INDICATION SIGNAL RECEIVED ONTIMESLOT 16

73 8074 ALARM INDICATION SIGNAL

RECEIVED ON TIMESLOT 16

Meaning

A piece of transmission equipment receives an alarm signal from another

piece of equipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 167: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 167/486

Page 168: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 168/486

168 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8075 S ALARM RECEIVED

74 8075 S ALARM RECEIVED

Meaning

A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 169: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 169/486

DN998797 169

Transmission Equipment Alarms (8000-8999) 8075 S ALARM RECEIVED

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 170: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 170/486

Page 171: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 171/486

Page 172: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 172/486

172 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8077 LOOPED SIGNAL RECEIVED

76 8077 LOOPED SIGNAL RECEIVED

Meaning

A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 173: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 173/486

DN998797 173

Transmission Equipment Alarms (8000-8999) 8077 LOOPED SIGNAL RECEIVED

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 174: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 174/486

174 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8078 MEASUREMENT SIGNAL RECEIVED

77 8078 MEASUREMENT SIGNAL RECEIVED

Meaning

A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 175: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 175/486

DN998797 175

Transmission Equipment Alarms (8000-8999) 8078 MEASUREMENT SIGNAL RECEIVED

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 176: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 176/486

176 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8079 TS16 CODE ERROR RECEIVED

78 8079 TS16 CODE ERROR RECEIVED

Meaning

A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 177: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 177/486

DN998797 177

Transmission Equipment Alarms (8000-8999) 8079 TS16 CODE ERROR RECEIVED

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 178: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 178/486

178 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8080 FRAME ERROR

79 8080 FRAME ERROR

Meaning

A framing error has been detected in the input signal.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 179: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 179/486

DN998797 179

Transmission Equipment Alarms (8000-8999) 8080 FRAME ERROR

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 180: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 180/486

180 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8081 LOSS OF FRAME ALIGNMENT

80 8081 LOSS OF FRAME ALIGNMENT

Meaning

A framing error has been detected in the input signal.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 181: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 181/486

Page 182: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 182/486

182 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8082 MULTIFRAME ALIGNMENT LOST

81 8082 MULTIFRAME ALIGNMENT LOST

Meaning

A framing error has been detected in the input signal.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 183: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 183/486

DN998797 183

Transmission Equipment Alarms (8000-8999) 8082 MULTIFRAME ALIGNMENT LOST

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 184: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 184/486

184 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8083 LOSS OF FRAME ALIGNMENT OF SUBSYS-TEM

82 8083 LOSS OF FRAME ALIGNMENT OF SUB-

SYSTEM

Meaning

A framing error has been detected in the input signal.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 185: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 185/486

DN998797 185

Transmission Equipment Alarms (8000-8999) 8083 LOSS OF FRAME ALIGNMENT OF SUBSYS-TEM

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 186: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 186/486

186 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8084 LOSS OF LINE FRAME ALIGNMENT

83 8084 LOSS OF LINE FRAME ALIGNMENT

Meaning

A framing error has been detected in the input signal.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 187: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 187/486

DN998797 187

Transmission Equipment Alarms (8000-8999) 8084 LOSS OF LINE FRAME ALIGNMENT

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 188: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 188/486

Page 189: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 189/486

DN998797 189

Transmission Equipment Alarms (8000-8999) 8085 LOSS OF RADIO FRAME ALIGNMENT

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 190: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 190/486

190 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8086 LOSS OF CRC MULTIFRAME ALIGNMENT

85 8086 LOSS OF CRC MULTIFRAME ALIGN-

MENT

Meaning

A framing error has been detected in the input signal.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 191: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 191/486

DN998797 191

Transmission Equipment Alarms (8000-8999) 8086 LOSS OF CRC MULTIFRAME ALIGNMENT

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Description: CRC multiframe alignment signal lost or not received

on PDH interface. CRC multiframe alignment word is conveyed in

TS0 spread over a multiframe consisting of 16 E1 frames. Far End

Alarm bit indication (TS0/b3) is sent in Tx direction.

Instructions:

1. Check that the interface settings are the same at both ends and

  the CRC is set in use.

2. Check that the far-end device is able to transmit signal with

  CRC multiframe alignment enabled.

3. Check the condition of cables, connectors and correct polarities

  of the wire pairs.

4. Check the signal quality of the transmission path to the alarming

  equipment.

5. Replace FIxx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically whenthe fault has been corrected.

Page 192: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 192/486

Page 193: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 193/486

Page 194: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 194/486

Page 195: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 195/486

Page 196: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 196/486

196 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8089 LOSS OF SIGNALLING FRAME

88 8089 LOSS OF SIGNALLING FRAME

Meaning

A framing error has been detected in the input signal.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 197: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 197/486

DN998797 197

Transmission Equipment Alarms (8000-8999) 8089 LOSS OF SIGNALLING FRAME

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 198: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 198/486

198 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8096 EXCESSIVE ERROR RATE

89 8096 EXCESSIVE ERROR RATE

Meaning

The bit error rate has been exceeded in the input signal.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 199: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 199/486

DN998797 199

Transmission Equipment Alarms (8000-8999) 8096 EXCESSIVE ERROR RATE

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 200: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 200/486

200 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8097 BIT ERROR RATIO (BER) > 1E-1

90 8097 BIT ERROR RATIO (BER) > 1E-1

Meaning

The bit error rate has been exceeded in the input signal.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 201: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 201/486

DN998797 201

Transmission Equipment Alarms (8000-8999) 8097 BIT ERROR RATIO (BER) > 1E-1

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 202: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 202/486

Page 203: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 203/486

DN998797 203

Transmission Equipment Alarms (8000-8999) 8098 BIT ERROR RATIO (BER) > 1E-2

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 204: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 204/486

Page 205: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 205/486

DN998797 205

Transmission Equipment Alarms (8000-8999) 8099 RECEIVED BIT ERROR RATIO (BER) > 1E-3

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE and Flexi Multiradio:

Description: Received signal has degraded on E1/T1 interface. Bit

Error Ratio (BER) is over 1E-3.

Instructions:

  1. If FIFA PIU is used, Refer to the FIFA product documentation

  for instructions.

  2. Check that the interface settings are correct for the link.

  3. Check quality of the E1/T1 line by enabling a Loop to

  Interface (line) at the far end equipment. If the alarm is

  cancelled during the loop test, check the far-end equipment.

  4. Equip an external cable loop to the interface to check that

  the interface in FIxx is ok. If the alarm is still active

  during the loop test, go to step 6.

  5. Check the condition of cables, connectors and correct

  polarities of the wire pairs.

  6. Check that FIxx is fully inserted in to ESMA.

  7. Replace FIxx.

  8. Check the signal quality of the transmission path to the

  alarming equipment.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 206: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 206/486

206 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8100 RECEIVED BIT ERROR RATIO (BER) > 1E-4

93 8100 RECEIVED BIT ERROR RATIO (BER) >

1E-4

Meaning

The bit error rate has been exceeded in the input signal.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 207: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 207/486

Page 208: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 208/486

208 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8101 RECEIVED BIT ERROR RATIO (BER) > 1E-5

94 8101 RECEIVED BIT ERROR RATIO (BER) >

1E-5

Meaning

The bit error rate has been exceeded in the input signal.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 209: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 209/486

DN998797 209

Transmission Equipment Alarms (8000-8999) 8101 RECEIVED BIT ERROR RATIO (BER) > 1E-5

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 210: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 210/486

210 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8102 RECEIVED BIT ERROR RATIO (BER) > 1E-6

95 8102 RECEIVED BIT ERROR RATIO (BER) >

1E-6

Meaning

The bit error rate has been exceeded in the input signal.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 211: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 211/486

Page 212: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 212/486

212 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8103 BIT ERROR RATIO (BER) > 1E-7

96 8103 BIT ERROR RATIO (BER) > 1E-7

Meaning

The bit error rate has been exceeded in the input signal.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 213: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 213/486

DN998797 213

Transmission Equipment Alarms (8000-8999) 8103 BIT ERROR RATIO (BER) > 1E-7

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 214: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 214/486

214 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8104 BIT ERROR RATIO (BER) > 1E-8

97 8104 BIT ERROR RATIO (BER) > 1E-8

Meaning

The bit error rate has been exceeded in the input signal.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 215: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 215/486

DN998797 215

Transmission Equipment Alarms (8000-8999) 8104 BIT ERROR RATIO (BER) > 1E-8

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 216: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 216/486

216 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8105 BIT ERROR RATIO (BER) > 1E-9

98 8105 BIT ERROR RATIO (BER) > 1E-9

Meaning

The bit error rate has been exceeded in the input signal.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 217: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 217/486

DN998797 217

Transmission Equipment Alarms (8000-8999) 8105 BIT ERROR RATIO (BER) > 1E-9

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 218: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 218/486

218 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8106 BIT ERROR RATIO (BER) > 1E-10

99 8106 BIT ERROR RATIO (BER) > 1E-10

Meaning

The bit error rate has been exceeded in the input signal.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 219: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 219/486

DN998797 219

Transmission Equipment Alarms (8000-8999) 8106 BIT ERROR RATIO (BER) > 1E-10

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 220: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 220/486

220 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8107 BIT ERROR RATIO (BER) > 1E-11

100 8107 BIT ERROR RATIO (BER) > 1E-11

Meaning

The bit error rate has been exceeded in the input signal.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 221: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 221/486

DN998797 221

Transmission Equipment Alarms (8000-8999) 8107 BIT ERROR RATIO (BER) > 1E-11

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 222: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 222/486

Page 223: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 223/486

DN998797 223

Transmission Equipment Alarms (8000-8999) 8108 BIT ERROR RATIO (BER) > 1E-12

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 224: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 224/486

224 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8109 FADING IN TRANSMISSION PATH

102 8109 FADING IN TRANSMISSION PATH

Meaning

Fading has been detected in the input signal.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 225: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 225/486

DN998797 225

Transmission Equipment Alarms (8000-8999) 8109 FADING IN TRANSMISSION PATH

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 226: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 226/486

226 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8110 SELECTIVE FADING IN TRANSMISSION PATH

103 8110 SELECTIVE FADING IN TRANSMISSION

PATH

Meaning

Fading has been detected in the input signal.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 227: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 227/486

Page 228: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 228/486

228 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8111 MODULATION ERROR

104 8111 MODULATION ERROR

Meaning

A modulation error has been detected in the received signal.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 229: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 229/486

DN998797 229

Transmission Equipment Alarms (8000-8999) 8111 MODULATION ERROR

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 230: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 230/486

Page 231: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 231/486

DN998797 231

Transmission Equipment Alarms (8000-8999) 8112 FREQUENCY ERROR

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE and Flexi Multiradio:

Description: The node is running on the internal clock as

configured in the timing priority list. This alarm can also be raised

in case synchronisation protection is configured, when the Rx source

signals from both directions have its MCBs in state '1' .

Instructions:

  1. Check that synchronisation priority list has Rx clock entries

  for used interfaces.

  2. In case FIFA PIU is used, check that the microwave link is

  commissioned and operational. Refer to FIFA product documentation

  for further instructions.

  3. If any of the alarms 8050, 8066, 8081, 8099, 8056 or 8073 are

  active, follow the instructions on them.

  4. Check that interface cables are correctly mated to FIxx. Check

  also condition of the connectors.

  5. If BTS is part of PDH loop protection configuration, check

  MCB/LCB configuration and operational state of loop network.

CancellingDo not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 232: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 232/486

232 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8113 BUFFER OVERFLOW

106 8113 BUFFER OVERFLOW

Meaning

A frequency error has been detected in the input signal.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 233: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 233/486

DN998797 233

Transmission Equipment Alarms (8000-8999) 8113 BUFFER OVERFLOW

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 234: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 234/486

234 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8119 SYNCHRONIZING FAULT IN TRANSMITTER

107 8119 SYNCHRONIZING FAULT IN TRANSMIT-

TER

Meaning

A synchronization error has been detected.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 235: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 235/486

DN998797 235

Transmission Equipment Alarms (8000-8999) 8119 SYNCHRONIZING FAULT IN TRANSMITTER

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 236: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 236/486

236 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8120 SYNCHRONIZING FAULT IN RECEIVER

108 8120 SYNCHRONIZING FAULT IN RECEIVER

Meaning

A synchronization error has been detected.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 237: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 237/486

DN998797 237

Transmission Equipment Alarms (8000-8999) 8120 SYNCHRONIZING FAULT IN RECEIVER

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 238: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 238/486

Page 239: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 239/486

DN998797 239

Transmission Equipment Alarms (8000-8999) 8121 SYNCHRONIZING FAULT IN AUXILIARYCHANNEL

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 240: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 240/486

240 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8122 SYNCHRONIZING FAULT

110 8122 SYNCHRONIZING FAULT

Meaning

A synchronization error has been detected.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 241: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 241/486

DN998797 241

Transmission Equipment Alarms (8000-8999) 8122 SYNCHRONIZING FAULT

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 242: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 242/486

242 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8123 SYNCHRONIZING FAULT IN CARRIER RE-COVERY

111 8123 SYNCHRONIZING FAULT IN CARRIER

RECOVERY

Meaning

A synchronization error has been detected.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 243: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 243/486

DN998797 243

Transmission Equipment Alarms (8000-8999) 8123 SYNCHRONIZING FAULT IN CARRIER RE-COVERY

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 244: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 244/486

244 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8124 SYNCHRONIZATION FAULT IN CLOCK RE-COVERY

112 8124 SYNCHRONIZATION FAULT IN CLOCK

RECOVERY

Meaning

A synchronization error has been detected.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 245: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 245/486

Page 246: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 246/486

Page 247: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 247/486

DN998797 247

Transmission Equipment Alarms (8000-8999) 8125 LOSS OF SYNCHRONIZATION SIGNAL

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Description: All defined synchronisation sources in the

synchronisation priority list are invalid or the list is empty. Node

is running on its internal clock.

Instructions:

  1. Check that synchronisation priority list has Rx clock entries

  for used interfaces.

  2. In case FIFA PIU is used, check that the microwave link is

  commissioned and operational. Refer to FIFA product

  documentation for further instructions.

  3. If any of the alarms 8050, 8066, 8081, 8099, 8056 or 8073 are

  active, follow the instructions on them.

  4. Check that interface cables are correctly mated to FIxx. Check

  also condition of the connectors.

  5. Replace FIxx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 248: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 248/486

248 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8126 UNIT FUNCTION DEGRADED

114 8126 UNIT FUNCTION DEGRADED

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 249: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 249/486

DN998797 249

Transmission Equipment Alarms (8000-8999) 8126 UNIT FUNCTION DEGRADED

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 250: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 250/486

250 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8127 EQUIPMENT FAULT DETECTED IN AUTOMAT-IC LOOP TEST

115 8127 EQUIPMENT FAULT DETECTED IN

AUTOMATIC LOOP TEST

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 251: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 251/486

DN998797 251

Transmission Equipment Alarms (8000-8999) 8127 EQUIPMENT FAULT DETECTED IN AUTOMAT-IC LOOP TEST

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 252: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 252/486

252 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8128 FAULT IN EQUIPMENT

116 8128 FAULT IN EQUIPMENT

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 253: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 253/486

DN998797 253

Transmission Equipment Alarms (8000-8999) 8128 FAULT IN EQUIPMENT

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 254: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 254/486

Page 255: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 255/486

Page 256: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 256/486

Page 257: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 257/486

DN998797 257

Transmission Equipment Alarms (8000-8999) 8130 FAULT IN MEMORY

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 258: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 258/486

258 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8131 INTERNAL BUS FAULT

119 8131 INTERNAL BUS FAULT

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 259: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 259/486

DN998797 259

Transmission Equipment Alarms (8000-8999) 8131 INTERNAL BUS FAULT

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 260: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 260/486

260 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8132 FAULT IN SUMMING UNIT

120 8132 FAULT IN SUMMING UNIT

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 261: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 261/486

DN998797 261

Transmission Equipment Alarms (8000-8999) 8132 FAULT IN SUMMING UNIT

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 262: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 262/486

262 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8133 FAULT IN MUX

121 8133 FAULT IN MUX

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 263: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 263/486

DN998797 263

Transmission Equipment Alarms (8000-8999) 8133 FAULT IN MUX

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 264: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 264/486

264 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8134 EXCHANGE LINE ALARM

122 8134 EXCHANGE LINE ALARM

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 265: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 265/486

DN998797 265

Transmission Equipment Alarms (8000-8999) 8134 EXCHANGE LINE ALARM

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 266: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 266/486

266 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8135 EQUIPMENT IN RESET

123 8135 EQUIPMENT IN RESET

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 267: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 267/486

DN998797 267

Transmission Equipment Alarms (8000-8999) 8135 EQUIPMENT IN RESET

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 268: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 268/486

268 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8136 AIS OSCILLATOR FAULT

124 8136 AIS OSCILLATOR FAULT

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 269: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 269/486

DN998797 269

Transmission Equipment Alarms (8000-8999) 8136 AIS OSCILLATOR FAULT

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 270: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 270/486

270 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8137 OSCILLATOR FAULT

125 8137 OSCILLATOR FAULT

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 271: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 271/486

DN998797 271

Transmission Equipment Alarms (8000-8999) 8137 OSCILLATOR FAULT

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 272: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 272/486

Page 273: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 273/486

DN998797 273

Transmission Equipment Alarms (8000-8999) 8138 PRESSURE ALARM

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 274: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 274/486

274 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8139 SUBRACK HAS MISSING UNITS

127 8139 SUBRACK HAS MISSING UNITS

Meaning

An installation or usage error has been detected in a piece ofequipment.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 275: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 275/486

DN998797 275

Transmission Equipment Alarms (8000-8999) 8139 SUBRACK HAS MISSING UNITS

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 276: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 276/486

276 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8140 SUBRACK HAS EXCESSIVE UNITS

128 8140 SUBRACK HAS EXCESSIVE UNITS

Meaning

An installation or usage error has been detected in a piece ofequipment.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 277: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 277/486

DN998797 277

Transmission Equipment Alarms (8000-8999) 8140 SUBRACK HAS EXCESSIVE UNITS

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 278: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 278/486

278 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8141 FORCED CONTROL ON

129 8141 FORCED CONTROL ON

Meaning

An installation or usage error has been detected in a piece ofequipment.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 279: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 279/486

DN998797 279

Transmission Equipment Alarms (8000-8999) 8141 FORCED CONTROL ON

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 280: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 280/486

280 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8142 INSTALLATION ERROR

130 8142 INSTALLATION ERROR

Meaning

An installation or usage error has been detected in a piece ofequipment.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 281: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 281/486

Page 282: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 282/486

282 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8143 FAULT IN CHANGE OVER FUNCTION

131 8143 FAULT IN CHANGE OVER FUNCTION

Meaning

An installation or usage error has been detected in a piece ofequipment.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 283: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 283/486

DN998797 283

Transmission Equipment Alarms (8000-8999) 8143 FAULT IN CHANGE OVER FUNCTION

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 284: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 284/486

284 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8144 OPERATING ERROR

132 8144 OPERATING ERROR

Meaning

An installation or usage error has been detected in a piece ofequipment.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 285: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 285/486

DN998797 285

Transmission Equipment Alarms (8000-8999) 8144 OPERATING ERROR

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 286: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 286/486

286 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8145 TEMPERATURE ALARM

133 8145 TEMPERATURE ALARM

Meaning

A piece of equipment has detected an environmental error.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 287: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 287/486

DN998797 287

Transmission Equipment Alarms (8000-8999) 8145 TEMPERATURE ALARM

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 288: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 288/486

288 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8146 WIND ALARM

134 8146 WIND ALARM

Meaning

A piece of equipment has detected an environmental error.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 289: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 289/486

DN998797 289

Transmission Equipment Alarms (8000-8999) 8146 WIND ALARM

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 290: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 290/486

290 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8147 LOCAL ALARM CANCEL WITHOUT ANY ALARM

135 8147 LOCAL ALARM CANCEL WITHOUT ANY

ALARM

Meaning

A piece of equipment has detected a usage or operation failure.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 291: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 291/486

DN998797 291

Transmission Equipment Alarms (8000-8999) 8147 LOCAL ALARM CANCEL WITHOUT ANY ALARM

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 292: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 292/486

292 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8148 EQUIPMENT RESET

136 8148 EQUIPMENT RESET

Meaning

A piece of equipment has detected a usage or operation failure.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 293: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 293/486

DN998797 293

Transmission Equipment Alarms (8000-8999) 8148 EQUIPMENT RESET

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Description: This warning is issued by Q1 device when reset has

occurred.

Instructions:

  1. Find out the alarming Q1 device and refer to its product

  documentation for more details on this warning message.

Cancelling

No cancelling.

Page 294: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 294/486

294 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8149 FORCED INDICATION

137 8149 FORCED INDICATION

Meaning

A piece of equipment has detected a usage or operation failure.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 295: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 295/486

DN998797 295

Transmission Equipment Alarms (8000-8999) 8149 FORCED INDICATION

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 296: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 296/486

296 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8150 FAULT IN UNIT

138 8150 FAULT IN UNIT

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 297: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 297/486

DN998797 297

Transmission Equipment Alarms (8000-8999) 8150 FAULT IN UNIT

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 298: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 298/486

298 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8151 FAULT IN CHANNEL

139 8151 FAULT IN CHANNEL

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 299: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 299/486

DN998797 299

Transmission Equipment Alarms (8000-8999) 8151 FAULT IN CHANNEL

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 300: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 300/486

300 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8152 FAULT IN BLOCK

140 8152 FAULT IN BLOCK

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 301: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 301/486

DN998797 301

Transmission Equipment Alarms (8000-8999) 8152 FAULT IN BLOCK

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 302: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 302/486

302 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8153 FAULT IN TRANSMITTER

141 8153 FAULT IN TRANSMITTER

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 303: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 303/486

DN998797 303

Transmission Equipment Alarms (8000-8999) 8153 FAULT IN TRANSMITTER

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 304: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 304/486

304 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8154 FAULT IN RECEIVER

142 8154 FAULT IN RECEIVER

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 305: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 305/486

DN998797 305

Transmission Equipment Alarms (8000-8999) 8154 FAULT IN RECEIVER

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 306: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 306/486

306 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8155 LASER BIAS OUT OF RANGE

143 8155 LASER BIAS OUT OF RANGE

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 307: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 307/486

DN998797 307

Transmission Equipment Alarms (8000-8999) 8155 LASER BIAS OUT OF RANGE

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 308: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 308/486

308 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8156 LASER POWER OUT OF RANGE

144 8156 LASER POWER OUT OF RANGE

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 309: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 309/486

DN998797 309

Transmission Equipment Alarms (8000-8999) 8156 LASER POWER OUT OF RANGE

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 310: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 310/486

310 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8157 LASER TEMPERATURE OUT OF RANGE

145 8157 LASER TEMPERATURE OUT OF

RANGE

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 311: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 311/486

DN998797 311

Transmission Equipment Alarms (8000-8999) 8157 LASER TEMPERATURE OUT OF RANGE

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 312: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 312/486

312 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8158 FORCED LASER CUT OFF

146 8158 FORCED LASER CUT OFF

Meaning

A piece of equipment has detected a fault in its operation.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 313: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 313/486

DN998797 313

Transmission Equipment Alarms (8000-8999) 8158 FORCED LASER CUT OFF

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 314: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 314/486

314 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8159 RUN DIAGNOSTICS TEST

147 8159 RUN DIAGNOSTICS TEST

Meaning

The equipment has detected a fault in a diagnostics test.This alarm affects the provided services. The unit may not be working

properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 315: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 315/486

DN998797 315

Transmission Equipment Alarms (8000-8999) 8159 RUN DIAGNOSTICS TEST

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 316: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 316/486

316 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8160 INTERFACE UNIT FAULT

148 8160 INTERFACE UNIT FAULT

Meaning

A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be

working properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 317: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 317/486

DN998797 317

Transmission Equipment Alarms (8000-8999) 8160 INTERFACE UNIT FAULT

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 318: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 318/486

318 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8161 CONNECTED TO REDUNDANT SYSTEM

149 8161 CONNECTED TO REDUNDANT SYSTEM

Meaning

A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be

working properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 319: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 319/486

DN998797 319

Transmission Equipment Alarms (8000-8999) 8161 CONNECTED TO REDUNDANT SYSTEM

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 320: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 320/486

320 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8162 DATABASE FULL

150 8162 DATABASE FULL

Meaning

A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be

working properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 321: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 321/486

DN998797 321

Transmission Equipment Alarms (8000-8999) 8162 DATABASE FULL

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Description: This warning is sent when the polling master

(BTS/BSC) is either unable to poll alarms from the Q1 device(s)

or it has not cleared the alarm history. Alarm history database has

become full.

Instructions:

  1. Find out the alarming Q1 device and refer to its product

  documentation for more details on this warning message.

Cancelling

No cancelling.

Page 322: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 322/486

322 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8163 REDUNDANT CONNECTION IN USE

151 8163 REDUNDANT CONNECTION IN USE

Meaning

A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be

working properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 323: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 323/486

DN998797 323

Transmission Equipment Alarms (8000-8999) 8163 REDUNDANT CONNECTION IN USE

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 324: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 324/486

324 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8164 LINE CABLE FAULT

152 8164 LINE CABLE FAULT

Meaning

A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be

working properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 325: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 325/486

DN998797 325

Transmission Equipment Alarms (8000-8999) 8164 LINE CABLE FAULT

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 326: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 326/486

326 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8165 REAL TIME LOST

153 8165 REAL TIME LOST

Meaning

A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be

working properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 327: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 327/486

DN998797 327

Transmission Equipment Alarms (8000-8999) 8165 REAL TIME LOST

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Description: Q1 device has not received real time from the polling

master (BTS/BSC). Time stamps are not displayed correctly.

Instructions:

  1. Find out the alarming Q1 device and refer to its product

  documentation for more details on this alarm.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 328: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 328/486

328 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8166 E1 CONVERTER RESET

154 8166 E1 CONVERTER RESET

Meaning

A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be

working properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 329: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 329/486

DN998797 329

Transmission Equipment Alarms (8000-8999) 8166 E1 CONVERTER RESET

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 330: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 330/486

330 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8167 E1 CONVERTER FAULT

155 8167 E1 CONVERTER FAULT

Meaning

A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be

working properly.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 331: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 331/486

DN998797 331

Transmission Equipment Alarms (8000-8999) 8167 E1 CONVERTER FAULT

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 332: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 332/486

332 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8168 EQUIPMENT DOOR OPEN

156 8168 EQUIPMENT DOOR OPEN

Meaning

A piece of equipment has detected a fault in its operation.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 333: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 333/486

DN998797 333

Transmission Equipment Alarms (8000-8999) 8168 EQUIPMENT DOOR OPEN

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 334: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 334/486

334 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8169 EXTENDED FAULT CODE IN USE

157 8169 EXTENDED FAULT CODE IN USE

Meaning

The BSC or BTS does not recognise the received fault code. Theequipment is supervised by the TMS4 polling system and does not

understand the extended fault codes.

This alarm may affect the provided services depending on the

actual fault.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Page 335: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 335/486

DN998797 335

Transmission Equipment Alarms (8000-8999) 8169 EXTENDED FAULT CODE IN USE

Id:0900d80580804c95

Confidential

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 336: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 336/486

336 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8172 YELLOW ALARM OCCURRED

158 8172 YELLOW ALARM OCCURRED

Meaning

The yellow alarm is sent by the equipment in the far-end, itindicates a serious fault in the received signal of the far-end

equipment.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 337: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 337/486

DN998797 337

Transmission Equipment Alarms (8000-8999) 8172 YELLOW ALARM OCCURRED

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Instructions:

  1. Check the far end equipment for alarms 8056, 8073, 8081.

  See the instructions on them.

  2. Apply Loop to interface (line) at far end to check that link

  is ok. If 8056/8073/8081 alarm is not active at near-end

  during the loop test the problem is at the far-end receiver.

  Note: 8172 Yellow alarm will be cancelled during this test.

  3. Equip an external cable loop to the interface to check that

  the interface in FIxx is ok. If 8056/8073/8081 alarm is active

  during the loop test, go to step 5. Note: 8172 Yellow alarm

  will be cancelled during this test.

  4. Check the condition of cables, connectors and correct

  polarities of the wire pairs.

  5. Check that FIxx is fully inserted in to ESMA.

  6. Replace FIxx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically whenthe fault has been corrected.

Flexi EDGE:

Do not cancel the alarm. The alarm is cancelled automatically when Yellow

alarm (RAI) clearance is detected according to ANSI T1.231.

Page 338: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 338/486

338 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8173 FAR-END ALARM 4

159 8173 FAR-END ALARM 4

Meaning

A piece of transmission equipment has received a far-end alarm.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 339: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 339/486

DN998797 339

Transmission Equipment Alarms (8000-8999) 8173 FAR-END ALARM 4

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 340: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 340/486

340 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8174 FAR-END ALARM 3

160 8174 FAR-END ALARM 3

Meaning

A piece of transmission equipment has received a far-end alarm.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 341: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 341/486

DN998797 341

Transmission Equipment Alarms (8000-8999) 8174 FAR-END ALARM 3

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 342: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 342/486

342 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8175 FAR-END ALARM 2

161 8175 FAR-END ALARM 2

Meaning

A piece of transmission equipment has received a far-end alarm.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 343: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 343/486

DN998797 343

Transmission Equipment Alarms (8000-8999) 8175 FAR-END ALARM 2

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 344: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 344/486

344 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8176 FAR-END ALARM RECEIVED

162 8176 FAR-END ALARM RECEIVED

Meaning

A piece of transmission equipment has received a far-end alarm.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 345: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 345/486

DN998797 345

Transmission Equipment Alarms (8000-8999) 8176 FAR-END ALARM RECEIVED

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 346: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 346/486

346 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8178 MULTIFRAME ALARM FROM FAR-END

163 8178 MULTIFRAME ALARM FROM FAR-END

Meaning

A piece of transmission equipment has received a far-end alarm.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 347: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 347/486

DN998797 347

Transmission Equipment Alarms (8000-8999) 8178 MULTIFRAME ALARM FROM FAR-END

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 348: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 348/486

348 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8179 FAR-END ALARM

164 8179 FAR-END ALARM

Meaning

Sent by the equipment in the far-end (TS0 Bit 3), which indicatesthat far-end equipment is unable to receive the signal.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 349: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 349/486

DN998797 349

Transmission Equipment Alarms (8000-8999) 8179 FAR-END ALARM

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Instructions:

  1. Check the far end equipment for alarms 8050, 8066, 8081

  and 8086. See the instructions on them.

  2. Apply Loop to interface (line) at far end to check that link

  is ok. If 8050/8066/8081/8086 alarm is not active at near-end

  during the loop test the problem is at the far-end receiver.

  Note: 8179 Far-end alarm will be cancelled during this test.

  3. Equip an external cable loop to the interface to check that

  the interface in FIxx is ok. If 8050/8066/8081/8086 alarm

  is active during the loop test, go to step 5.

  Note: 8179 Far-end alarm will be cancelled during this test.

  4. Check the condition of cables, connectors and correct

  polarities of the wire pairs.

  5. Check that FIxx is fully inserted in to ESMA.

  6. Replace FIxx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically whenthe fault has been corrected.

Page 350: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 350/486

350 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8180 ALARM FROM FAR-END SUBSYSTEM

165 8180 ALARM FROM FAR-END SUBSYSTEM

Meaning

A piece of transmission equipment has received a far-end alarm.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 351: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 351/486

DN998797 351

Transmission Equipment Alarms (8000-8999) 8180 ALARM FROM FAR-END SUBSYSTEM

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 352: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 352/486

352 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8181 FAR-END SENDING FAULT

166 8181 FAR-END SENDING FAULT

Meaning

A piece of transmission equipment has received a far-end alarm.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 353: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 353/486

DN998797 353

Transmission Equipment Alarms (8000-8999) 8181 FAR-END SENDING FAULT

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 354: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 354/486

354 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8182 FAULT IN FAR-END RECEIVING

167 8182 FAULT IN FAR-END RECEIVING

Meaning

A piece of transmission equipment has received a far-end alarm.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 355: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 355/486

DN998797 355

Transmission Equipment Alarms (8000-8999) 8182 FAULT IN FAR-END RECEIVING

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 356: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 356/486

356 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8183 FAR-END SYNCHRONIZATION ALARM

168 8183 FAR-END SYNCHRONIZATION ALARM

Meaning

A piece of transmission equipment has received a far-end alarm.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 357: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 357/486

DN998797 357

Transmission Equipment Alarms (8000-8999) 8183 FAR-END SYNCHRONIZATION ALARM

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 358: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 358/486

358 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8184 REAL TIME UPDATED

169 8184 REAL TIME UPDATED

Meaning

Real time is updated to the equipment. The equipment's time changeexceeds the alarm threshold.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 359: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 359/486

DN998797 359

Transmission Equipment Alarms (8000-8999) 8184 REAL TIME UPDATED

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

This alarm does not require any action. The system has updated

the equipment time more than the alarm threshold.

See the equipment operating manual for more detailed information on

the fault code.

Cancelling

No cancelling.

Page 360: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 360/486

360 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8185 CONNECTION OR SETTINGS HAVECHANGED

170 8185 CONNECTION OR SETTINGS HAVE

CHANGED

Meaning

Connection or settings have changed in a piece of transmission

equipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 361: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 361/486

DN998797 361

Transmission Equipment Alarms (8000-8999) 8185 CONNECTION OR SETTINGS HAVECHANGED

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 362: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 362/486

362 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8186 CONFIGURATION ERROR

171 8186 CONFIGURATION ERROR

Meaning

A configuration error has been detected in a piece of equipment.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 363: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 363/486

DN998797 363

Transmission Equipment Alarms (8000-8999) 8186 CONFIGURATION ERROR

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 364: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 364/486

364 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8190 CUSTOMER SPECIFIC FAULT CODE 1

172 8190 CUSTOMER SPECIFIC FAULT CODE 1

Meaning

This alarm is generated from a customer specific fault code.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 365: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 365/486

DN998797 365

Transmission Equipment Alarms (8000-8999) 8190 CUSTOMER SPECIFIC FAULT CODE 1

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 366: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 366/486

366 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8191 CUSTOMER SPECIFIC FAULT CODE 2

173 8191 CUSTOMER SPECIFIC FAULT CODE 2

Meaning

This alarm is generated from a customer specific fault code.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 367: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 367/486

DN998797 367

Transmission Equipment Alarms (8000-8999) 8191 CUSTOMER SPECIFIC FAULT CODE 2

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 368: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 368/486

368 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8192 CUSTOMER SPECIFIC FAULT CODE 3

174 8192 CUSTOMER SPECIFIC FAULT CODE 3

Meaning

This alarm is generated from a customer specific fault code.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 369: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 369/486

DN998797 369

Transmission Equipment Alarms (8000-8999) 8192 CUSTOMER SPECIFIC FAULT CODE 3

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 370: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 370/486

370 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8193 CUSTOMER SPECIFIC FAULT CODE 4

175 8193 CUSTOMER SPECIFIC FAULT CODE 4

Meaning

This alarm is generated from a customer specific fault code.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 371: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 371/486

DN998797 371

Transmission Equipment Alarms (8000-8999) 8193 CUSTOMER SPECIFIC FAULT CODE 4

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 372: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 372/486

372 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8194 CUSTOMER SPECIFIC FAULT CODE 5

176 8194 CUSTOMER SPECIFIC FAULT CODE 5

Meaning

This alarm is generated from a customer specific fault code.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 373: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 373/486

DN998797 373

Transmission Equipment Alarms (8000-8999) 8194 CUSTOMER SPECIFIC FAULT CODE 5

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 374: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 374/486

374 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8195 V5 PROTOCOL ALARM

177 8195 V5 PROTOCOL ALARM

Meaning

This alarm is generated from a customer specific fault code.

This alarm may affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 375: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 375/486

DN998797 375

Transmission Equipment Alarms (8000-8999) 8195 V5 PROTOCOL ALARM

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 376: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 376/486

376 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8200 LOSS OF PRIMARY SUPERVISION CONNEC-TION

178 8200 LOSS OF PRIMARY SUPERVISION

CONNECTION

Meaning

A piece of equipment has detected a supervision connection fault.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 377: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 377/486

DN998797 377

Transmission Equipment Alarms (8000-8999) 8200 LOSS OF PRIMARY SUPERVISION CONNEC-TION

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 378: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 378/486

378 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8201 LOSS OF SECONDARY SUPERVISION CON-NECTION

179 8201 LOSS OF SECONDARY SUPERVISION

CONNECTION

Meaning

A piece of equipment has detected a supervision connection fault.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined  Included only if the equipment is supervised by a BTS that

Page 379: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 379/486

DN998797 379

Transmission Equipment Alarms (8000-8999) 8201 LOSS OF SECONDARY SUPERVISION CON-NECTION

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 380: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 380/486

380 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8202 LOSS OF SUPERVISION CONNECTION

180 8202 LOSS OF SUPERVISION CONNECTION

Meaning

A piece of equipment has detected a supervision connection fault.This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 381: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 381/486

DN998797 381

Transmission Equipment Alarms (8000-8999) 8202 LOSS OF SUPERVISION CONNECTION

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Description: Q1 device doesn't respond to poll command sent by the

polling master (BTS/BSC).

Instructions:

  1. Check that Q1 baud rate and Q1 address of the Q1 device matches

  with what is configured at the BSC.

  2. Check if alarm 7601 "Q1 bus faulty" is active. Check that the

  cable is correctly mated with the ESMA and Q1 device. Check also

  condition of the Q1 cable connectors.

  3. Check that Q1 switches are set to enable polling master (BTS/BSC)

  to access the microprocessor (up) of the Q1 device.

  4. Replace ESMA.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 382: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 382/486

382 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8203 LOSS OF SUPERVISION BUS

181 8203 LOSS OF SUPERVISION BUS

Meaning

A piece of equipment has detected a supervision connection fault.This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 383: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 383/486

DN998797 383

Transmission Equipment Alarms (8000-8999) 8203 LOSS OF SUPERVISION BUS

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 384: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 384/486

384 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8206 CONGESTION

182 8206 CONGESTION

Meaning

There is congestion in the equipment or in the plug-in unit. Resource orservice has congestion and requested operation cannot be executed.

This alarm affects the provided services. The unit is not working

properly and the unit services may be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If the equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 385: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 385/486

DN998797 385

Transmission Equipment Alarms (8000-8999) 8206 CONGESTION

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 386: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 386/486

386 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8207 CALIBRATION EXPIRED

183 8207 CALIBRATION EXPIRED

Meaning

Recalibration is needed.

This alarm may affect the provided services. The unit is not working

properly and the unit services may be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 387: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 387/486

DN998797 387

Transmission Equipment Alarms (8000-8999) 8207 CALIBRATION EXPIRED

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 388: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 388/486

388 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8213 REMOTE DEFECT INDICATION (RDI)

184 8213 REMOTE DEFECT INDICATION (RDI)

Meaning

A remote end indicates failure in the termination point.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 389: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 389/486

DN998797 389

Transmission Equipment Alarms (8000-8999) 8213 REMOTE DEFECT INDICATION (RDI)

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 390: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 390/486

390 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8214 SIGNAL DEGRADED

185 8214 SIGNAL DEGRADED

Meaning

The signal is degraded.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 391: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 391/486

DN998797 391

Transmission Equipment Alarms (8000-8999) 8214 SIGNAL DEGRADED

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 392: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 392/486

392 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8215 TRACE IDENTIFIER MISMATCH

186 8215 TRACE IDENTIFIER MISMATCH

Meaning

The trace identifier does not match the expected one.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 393: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 393/486

DN998797 393

Transmission Equipment Alarms (8000-8999) 8215 TRACE IDENTIFIER MISMATCH

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 394: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 394/486

394 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8216 UNEQUIPPED SIGNAL

187 8216 UNEQUIPPED SIGNAL

Meaning

Virtual Container (VC) does not carry valid payload data because thecross-connection is not configured.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 395: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 395/486

DN998797 395

Transmission Equipment Alarms (8000-8999) 8216 UNEQUIPPED SIGNAL

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 396: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 396/486

396 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8221 VERSION MISMATCH

188 8221 VERSION MISMATCH

Meaning

The software or program version is not compatible with the hardware,other software versions or software information.

This alarm affects the provided services. The unit is not working

properly and the unit services may be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 397: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 397/486

DN998797 397

Transmission Equipment Alarms (8000-8999) 8221 VERSION MISMATCH

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 398: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 398/486

398 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8222 CORRUPT DATA

189 8222 CORRUPT DATA

Meaning

The received or stored data is corrupted. The data content is notwhat it was expected to be.

This alarm affects the provided services. The unit is not working

properly and the unit services may be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 399: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 399/486

DN998797 399

Transmission Equipment Alarms (8000-8999) 8222 CORRUPT DATA

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 400: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 400/486

Page 401: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 401/486

DN998797 401

Transmission Equipment Alarms (8000-8999) 8223 PROTECTION SWITCH

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 402: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 402/486

402 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8230 THRESHOLD CROSSED

191 8230 THRESHOLD CROSSED

Meaning

A piece of equipment has detected a performance monitoring fault.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 ascii string of the piece of transmission equipment type.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 403: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 403/486

DN998797 403

Transmission Equipment Alarms (8000-8999) 8230 THRESHOLD CROSSED

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 404: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 404/486

404 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8240 ACTIVE ALARM POINT

192 8240 ACTIVE ALARM POINT

Meaning

This is an external alarm connected to a piece of transmissionequipment.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

Page 405: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 405/486

DN998797 405

Transmission Equipment Alarms (8000-8999) 8240 ACTIVE ALARM POINT

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Flexi EDGE:

Description: This is an external user-defined alarm. This alarm is

activated at the external equipment. Alarrm line number is mapped to

Supervision Block number. EAC lines can be routed via EAC port at ESMA

or via FSEx connected to ESMA.

Instructions:

  1. Check that the relevant EAC line is correctly configured at the

  BSC (MML command ZEFO:<id>:IOP;).

  2. Check equipment connected to alarming EAC line.

  3. Check that the cable chain is correctly mated between ESMA and

  the external equipment.

  4. Check the ESMA and replace it if faulty.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 406: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 406/486

Page 407: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 407/486

DN998797 407

Transmission Equipment Alarms (8000-8999) 8241 UPPER ALARM LIMIT EXCEEDED

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 408: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 408/486

Page 409: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 409/486

DN998797 409

Transmission Equipment Alarms (8000-8999) 8242 LOWER ALARM LIMIT EXCEEDED

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 410: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 410/486

410 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8250 INVALID TIME

195 8250 INVALID TIME

Meaning

This is a transmission equipment alarm generated by a mediator device.The mediator has detected that the time in the alarm is in the future

or too far away in the past.

This alarm affects the provided services. The unit is not working

properly and the unit services may be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 411: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 411/486

DN998797 411

Transmission Equipment Alarms (8000-8999) 8250 INVALID TIME

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 412: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 412/486

412 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8254 OPERATOR DISABLED

196 8254 OPERATOR DISABLED

Meaning

This is a transmission equipment alarm generated by a mediator device.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 413: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 413/486

DN998797 413

Transmission Equipment Alarms (8000-8999) 8254 OPERATOR DISABLED

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 414: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 414/486

414 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8256 15 MIN G826 ES THRESHOLD CROSSED

197 8256 15 MIN G826 ES THRESHOLD

CROSSED

Meaning

A piece of equipment has detected a performance monitoring fault.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 415: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 415/486

DN998797 415

Transmission Equipment Alarms (8000-8999) 8256 15 MIN G826 ES THRESHOLD CROSSED

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 416: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 416/486

416 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8257 15 MIN G826 SES THRESHOLD CROSSED

198 8257 15 MIN G826 SES THRESHOLD

CROSSED

Meaning

A piece of equipment has detected a performance monitoring fault.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 417: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 417/486

DN998797 417

Transmission Equipment Alarms (8000-8999) 8257 15 MIN G826 SES THRESHOLD CROSSED

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 418: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 418/486

418 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8258 15 MIN G826 BBE THRESHOLD CROSSED

199 8258 15 MIN G826 BBE THRESHOLD

CROSSED

Meaning

A piece of equipment has detected a performance monitoring fault.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 419: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 419/486

DN998797 419

Transmission Equipment Alarms (8000-8999) 8258 15 MIN G826 BBE THRESHOLD CROSSED

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 420: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 420/486

420 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8259 24 H G826 ES THRESHOLD CROSSED

200 8259 24 H G826 ES THRESHOLD CROSSED

Meaning

A piece of equipment has detected a performance monitoring fault.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 421: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 421/486

DN998797 421

Transmission Equipment Alarms (8000-8999) 8259 24 H G826 ES THRESHOLD CROSSED

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 422: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 422/486

422 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8260 24 H G826 SES THRESHOLD CROSSED

201 8260 24 H G826 SES THRESHOLD CROSSED

Meaning

A piece of equipment has detected a performance monitoring fault.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 423: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 423/486

DN998797 423

Transmission Equipment Alarms (8000-8999) 8260 24 H G826 SES THRESHOLD CROSSED

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 424: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 424/486

424 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8261 24 H G826 BBE THRESHOLD CROSSED

202 8261 24 H G826 BBE THRESHOLD CROSSED

Meaning

A piece of equipment has detected a performance monitoring fault.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 425: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 425/486

DN998797 425

Transmission Equipment Alarms (8000-8999) 8261 24 H G826 BBE THRESHOLD CROSSED

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 426: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 426/486

426 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8262 STATISTIC UNAVAILABILITY

203 8262 STATISTIC UNAVAILABILITY

Meaning

A piece of equipment has detected a performance monitoring fault.

This alarm does not affect the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 427: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 427/486

DN998797 427

Transmission Equipment Alarms (8000-8999) 8262 STATISTIC UNAVAILABILITY

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 428: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 428/486

428 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8263 STATISTIC RESET

204 8263 STATISTIC RESET

Meaning

A piece of equipment has detected a performance monitoring fault.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 429: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 429/486

DN998797 429

Transmission Equipment Alarms (8000-8999) 8263 STATISTIC RESET

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 430: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 430/486

430 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8264 15 MIN T/RLTS THRESHOLD CROSSED

205 8264 15 MIN T/RLTS THRESHOLD CROSSED

Meaning

In the radio interface a T/RLTS is a one-second period during whichthe detected transmitted level (TL) value is higher or the received

level (RL) value is lower than a predefined reference threshold.

If the number of seconds counted in a time interval is higher than

the predefined threshold value, this event is generated.

This alarm affects the provided services. The unit is not working

properly and the unit services may be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Page 431: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 431/486

DN998797 431

Transmission Equipment Alarms (8000-8999) 8264 15 MIN T/RLTS THRESHOLD CROSSED

Id:0900d80580804c95

Confidential

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 432: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 432/486

432 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8265 24 H T/RLTS THRESHOLD CROSSED

206 8265 24 H T/RLTS THRESHOLD CROSSED

Meaning

In the radio interface a T/RLTS is a one-second period during whichthe detected transmitted level (TL) value is higher or the received

level (RL) value is lower than a predefined reference threshold.

If the number of seconds counted in a time interval is higher than

a predefined threshold value, this event is generated.

This alarm affects the provided services. The unit is not working

properly and the unit services may be lost.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Page 433: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 433/486

DN998797 433

Transmission Equipment Alarms (8000-8999) 8265 24 H T/RLTS THRESHOLD CROSSED

Id:0900d80580804c95

Confidential

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

No cancelling.

Page 434: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 434/486

434 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8266 LICENCE KEY NOT VALID

207 8266 LICENCE KEY NOT VALID

Meaning

The licence key does not fit the unit or the feature.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 435: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 435/486

DN998797 435

Transmission Equipment Alarms (8000-8999) 8266 LICENCE KEY NOT VALID

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 436: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 436/486

436 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8267 LICENCE EXPIRED

208 8267 LICENCE EXPIRED

Meaning

Licence has expired. The feature has been deactivated.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 437: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 437/486

DN998797 437

Transmission Equipment Alarms (8000-8999) 8267 LICENCE EXPIRED

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 438: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 438/486

438 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8268 LICENCE WILL EXPIRE IN THE NEAR FUTURE

209 8268 LICENCE WILL EXPIRE IN THE NEAR

FUTURE

Meaning

The licence is time limited. The feature will not be usable after

licence expiration.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 439: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 439/486

DN998797 439

Transmission Equipment Alarms (8000-8999) 8268 LICENCE WILL EXPIRE IN THE NEAR FUTURE

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 440: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 440/486

440 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8269 LICENCE FOR FEATURE IS NOT AVAILABLE

210 8269 LICENCE FOR FEATURE IS NOT AVAIL-

ABLE

Meaning

The feature cannot be activated without a licence.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined  Included only if the equipment is supervised by a BTS that

Page 441: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 441/486

DN998797 441

Transmission Equipment Alarms (8000-8999) 8269 LICENCE FOR FEATURE IS NOT AVAILABLE

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 442: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 442/486

442 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8270 LICENCE FOR FEATURE HAS BEEN ACTIVAT-ED

211 8270 LICENCE FOR FEATURE HAS BEEN

ACTIVATED

Meaning

The user has activated the licence for the feature.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined  Included only if the equipment is supervised by a BTS that

Page 443: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 443/486

DN998797 443

Transmission Equipment Alarms (8000-8999) 8270 LICENCE FOR FEATURE HAS BEEN ACTIVAT-ED

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 444: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 444/486

444 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8271 LICENCE FOR FEATURE HAS BEEN DEACTI-VATED

212 8271 LICENCE FOR FEATURE HAS BEEN

DEACTIVATED

Meaning

The user has deactivated the licence for the feature.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined  Included only if the equipment is supervised by a BTS that

Page 445: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 445/486

DN998797 445

Transmission Equipment Alarms (8000-8999) 8271 LICENCE FOR FEATURE HAS BEEN DEACTI-VATED

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 446: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 446/486

446 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8272 POSITION NOT LOCKED

213 8272 POSITION NOT LOCKED

Meaning

The global positioning system (GPS) position is not locked becausea GPS receiver self survey is ongoing. The location measurement unit(LMU)

GPS position is not locked. A minimum of four satellite signals are

needed to achieve GPS FIX.

The GPS position survey takes about 24 hours with a good satellite view.

If the self survey is not completed within a reasonable time(it may take

from one to five days), check the GPS antenna installation.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies the physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 the number of the Q1 service channel in the BSC. The number can

  be 0...27. If the equipment is supervised by the BTS, the channel

  number is not relevant

6 the name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

7 the number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of  the alarm printout.

  For more information, see the alarm's instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Page 447: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 447/486

DN998797 447

Transmission Equipment Alarms (8000-8999) 8272 POSITION NOT LOCKED

Id:0900d80580804c95

Confidential

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check the Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, open a remote session to the

transmission equipment and display the fault information.

For more detailed information on the fault code and corrective actions,

see the equipment's operating manual.

Flexi EDGE:

Description: The LMUB power is out of its normal operating limits or the

fuse-link is blown due to over-current.

Instructions:

Refer to the Location Measurement Unit (LMUB) product documentation for

troubleshooting information.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 448: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 448/486

448 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8273 LICENCE FOR 2G FLEXI ABIS OVER IP/ETH-ERNET IS NOT AVAILABLE

214 8273 LICENCE FOR 2G FLEXI ABIS OVER

IP/ETHERNET IS NOT AVAILABLE

Meaning

The feature cannot be activated without a licence.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies the physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 the number of the Q1 service channel in the BSC, 0...27.

  If the equipment is supervised by the BTS, the channel number

  is not relevant

6 the name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined  Included only if the equipment is supervised by a BTS that

Page 449: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 449/486

DN998797 449

Transmission Equipment Alarms (8000-8999) 8273 LICENCE FOR 2G FLEXI ABIS OVER IP/ETH-ERNET IS NOT AVAILABLE

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check the Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, open a remote session to the

transmission equipment and display the fault information.

For more detailed information on the fault code and corrective actions,

see the equipment's operating manual.

Flexi EDGE and Flexi Multiradio:

Description: Transmission is commissioned to be in Pseudowire

(PWE) mode without a licence or without configuring the BSC.

Instructions:

  1. Check the status of the '2G Flexi Abis over IP/

  Ethernet' feature at the BSC, and if needed, install

  and/or activate it.

  2. Configure the '2G Flexi Abis over IP/Ethernet' feature

  in the BSC.

Alternatively, you can:

  1. Recommission the site to use TDM mode.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 450: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 450/486

450 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8274 LICENCE FOR 2G FLEXI ADDITIONAL 2 E1/T1IS NOT AVAILABLE

215 8274 LICENCE FOR 2G FLEXI ADDITIONAL 2

E1/T1 IS NOT AVAILABLE

Meaning

The feature cannot be activated without a licence.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies the physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 the number of the Q1 service channel in the BSC, 0...27.

  If the equipment is supervised by the BTS, the channel number

  is not relevant

6 the name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined  Included only if the equipment is supervised by a BTS that

Page 451: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 451/486

DN998797 451

Transmission Equipment Alarms (8000-8999) 8274 LICENCE FOR 2G FLEXI ADDITIONAL 2 E1/T1IS NOT AVAILABLE

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check the Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, open a remote session to

the transmission equipment and display the fault information.

For more detailed information on the fault code and corrective actions,

see the equipment's operating manual.

Flexi EDGE and Flexi Multiradio:

Description: The number of used E1/T1 interfaces with terminated

Abis traffic is higher than the number of licensed E1/T1 interfaces

or the number of the E1/T1 interfaces configured in the BSC.

Instructions:

  1. Check the status of the '2G Flexi Additional 2 E1/T1'

  feature at the BSC, and if needed, install and/or activate

  it.

  2. Configure the '2G Flexi Additional 2 E1/T1' feature by

  increasing the number of licensed E1/T1 interfaces at the

  BSC.

Alternatively, you can:

  1. Reduce the number of E1/T1 interfaces exceeding the licence:

  a. Remove the terminated Abis allocations from the number of

  exceeded interfaces.

  OR

  b. Set the exceeded number of interfaces to 'Not in Use'

  state.

Note: Only two E1/T1 interfaces are licence free. One licence will

increase the number of E1/T1 interfaces by two.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 452: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 452/486

452 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8275 LICENCE FOR 2G FLEXI ABIS TRS GROOM-ING IS NOT AVAILABLE

216 8275 LICENCE FOR 2G FLEXI ABIS TRS

GROOMING IS NOT AVAILABLE

Meaning

The feature cannot be activated without a licence.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies the physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 the number of the Q1 service channel in the BSC, 0...27.

  If the equipment is supervised by the BTS, the channel number

  is not relevant

6 the name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined  Included only if the equipment is supervised by a BTS that

Page 453: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 453/486

DN998797 453

Transmission Equipment Alarms (8000-8999) 8275 LICENCE FOR 2G FLEXI ABIS TRS GROOM-ING IS NOT AVAILABLE

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check the Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, open a remote session to

the transmission equipment and display the fault information.

For more detailed information on the fault code and corrective actions,

see the equipment's operating manual.

Flexi EDGE and Flexi Multiradio:

Description: Bypass cross-connections are configured in used E1/T1

interfaces without a licence or without configuring the BSC.

Instructions:

  1. Check the status of the '2G Flexi Abis TRS Grooming'

  feature at the BSC, and if needed, install and/or activate

  it.

  2. Configure the '2G Flexi Abis TRS Grooming' feature

  in the BSC.

Alternatively, you can:

  1. Disable all the cross-connections which are controlled by

  '2G Flexi Abis TRS Grooming'.

Note: Bi-directional cross-connections controlled by '2G Flexi Abis

TRS Grooming' are of the following granularities: 8 kBit/s,

16 kBit/s, 32 kBit/s, 64 kBit/s and n*64 kBit/s.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 454: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 454/486

454 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8276 LICENCE FOR 2G FLEXI TRS LOOP PROTEC-TION IS NOT AVAILABLE

217 8276 LICENCE FOR 2G FLEXI TRS LOOP

PROTECTION IS NOT AVAILABLE

Meaning

The feature cannot be activated without a licence.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies the physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 the number of the Q1 service channel in the BSC, 0...27.

  If the equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined  Included only if the equipment is supervised by a BTS that

Page 455: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 455/486

DN998797 455

Transmission Equipment Alarms (8000-8999) 8276 LICENCE FOR 2G FLEXI TRS LOOP PROTEC-TION IS NOT AVAILABLE

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check the Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, open a remote session to the

transmission equipment and display the fault information.

For more detailed information on the fault code and corrective actions,

see the equipment's operating manual.

Flexi EDGE and Flexi Multiradio:

Description: Abis protection and/or protected cross-connections are

configured in used E1/T1 interfaces without a licence or without

configuring the BSC.

Instructions:

  1. Check the status of the '2G Flexi TRS Loop Protection'

  feature at the BSC, and if needed, install and/or activate

  it.

  2. Configure the '2G Flexi TRS Loop Protection' feature in

  the BSC.

Alternatively, you can:

  1. Disable all cross-connections which are controlled by

  '2G Flexi TRS Loop Protection'.

Note: Protected bi-directional cross-connections, Masked

bi-directional cross-connections and Abis protection are

controlled by '2G Flexi TRS Loop Protection'.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically whenthe fault has been corrected.

Page 456: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 456/486

456 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8277 ETHERNET PHYSICAL LINK LAYER LOST

218 8277 ETHERNET PHYSICAL LINK LAYER

LOST

Meaning

Incoming ethernet link connectivity is lost because of a broken or

missing cable, loose connector, or high attenuation on ethernet link.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies the physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 the number of the Q1 service channel in the BSC. The number can

  be 0...27. If the equipment is supervised by the BTS, the channel  number is not relevant

6 the name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

7 the number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 457: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 457/486

DN998797 457

Transmission Equipment Alarms (8000-8999) 8277 ETHERNET PHYSICAL LINK LAYER LOST

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check the Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, open a remote session to the

transmission equipment and display the fault information.

For more detailed information on the fault code and corrective actions,

see the equipment's operating manual.

Flexi EDGE and Flexi Multiradio:

Description: Physical Ethernet link is detected to be down.

Instructions:

1. Check that the Ethernet cable is connected to the right interface and

  the cable is correctly mated to the PIU. Check the condition of

  cables and connectors. Check that the length/type of the cable does not

  introduce excessive attenuation.

2. Check that the device connected to the FIxx PIU supports 100 Base-T,

  full duplex mode and autonegotiation.

3. Check that the device connected to the FIxx PIU has correct settings,

  such as autonegotiation and Ethernet interface enabled.

4. Replace FIxx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 458: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 458/486

458 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8278 PSEUDOWIRE DOWN

219 8278 PSEUDOWIRE DOWN

Meaning

Pseudowire connection is lost. There is a configuration mismatch ofpseudowire (PW) parameters between pseudowire emulation edge to edge

(PWE) near and far end, or a cut in connection in the packet switched

network because of a link/equipment defect or very high congestion.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies the physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 the number of the Q1 service channel in the BSC. The number can

  be 0...27. If the equipment is supervised by the BTS, the channel

  number is not relevant

6 the name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

7 the number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 459: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 459/486

DN998797 459

Transmission Equipment Alarms (8000-8999) 8278 PSEUDOWIRE DOWN

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check the Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, open a remote session to thetransmission equipment and display the fault information.

For more detailed information on the fault code and corrective actions,

see the equipment's operating manual.

Flexi EDGE and Flexi Multiradio:

Description: The incoming pseudowire connection is down. There is a fault

in the connection of the pseudowire. R bit is set at the CESoPSN control

word and sent in the Tx direction.

Instructions:

1. Check the pseudowire and pseudowire tunnel configuration settings at

  both ends.

2. Check the conditions in the transmission path of the pseudowire tunnel

  at the packet switched network.

3. Replace FIxx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 460: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 460/486

460 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8279 PSEUDOWIRE PERFORMANCE DEGRADED

220 8279 PSEUDOWIRE PERFORMANCE

DEGRADED

Meaning

The performance of pseudowire is below the threshold. There is high

delay, delay variation, or excessive packet loss because of high load

in the packet switched network. The jitter buffer size is insufficient.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies the physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 the number of the Q1 service channel in the BSC. The number can  be 0...27. If the equipment is supervised by the BTS, the channel

  number is not relevant

6 the name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

7 the number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 461: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 461/486

DN998797 461

Transmission Equipment Alarms (8000-8999) 8279 PSEUDOWIRE PERFORMANCE DEGRADED

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check the Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, open a remote session to thetransmission equipment and display the fault information.

For more detailed information on the fault code and corrective actions,

see the equipment's operating manual.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 462: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 462/486

462 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8280 PSEUDOWIRE REMOTE PACKET LOSS

221 8280 PSEUDOWIRE REMOTE PACKET LOSS

Meaning

The far-end pseudowire emulation edge to edge (PWE) equipment signalsare defect in the received pseudowire (PW) signal of the far-end PWE

equipment. There is a PW parameter configuration mismatch between the

PWE near and far end, a unidirectional cut in connection in the packet

switched network because of a link/equipment defect, or very high

congestion.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies the physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 the number of the Q1 service channel in the BSC. The number can

  be 0...27. If the equipment is supervised by the BTS, the channel

  number is not relevant

6 the name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

7 the number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of  the alarm printout.

  For more information, see the alarm's instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Page 463: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 463/486

DN998797 463

Transmission Equipment Alarms (8000-8999) 8280 PSEUDOWIRE REMOTE PACKET LOSS

Id:0900d80580804c95

Confidential

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check the Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, open a remote session to the

transmission equipment and display the fault information.

For more detailed information on the fault code and corrective actions,

see the equipment's operating manual.

Flexi EDGE and Flexi Multiradio:

Description: Signalled by the equipment in the far-end; indicates a

serious fault in the received signal at the far-end equipment.

Instructions:

1. Check for alarms at the far-end equipment. See instructions on them.

2. Check the condition of the cables and connectors, and the correct

  polarities of the wire pairs at both ends.

3. Check that the pseudowire and pseudowire tunnel settings are correct

  at both ends.

4. Check the transmission path of the pseudowire tunnel from the alarming

  interface to the far end.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 464: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 464/486

464 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8281 FAULT IN OPTICAL INTERFACE (SFP)

222 8281 FAULT IN OPTICAL INTERFACE (SFP)

Meaning

A fault has been detected on the ethernet SFP interface. The insertedSFP module type is not supported, the inserted SFP module type could

not be identified, or there is a SFP module signals fault in the

transmitter.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies the physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 the number of the Q1 service channel in the BSC. The number can

  be 0...27. If the equipment is supervised by the BTS, the channel

  number is not relevant

6 the name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

7 the number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

Page 465: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 465/486

DN998797 465

Transmission Equipment Alarms (8000-8999) 8281 FAULT IN OPTICAL INTERFACE (SFP)

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check the Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, open a remote session to thetransmission equipment and display the fault information.

For more detailed information on the fault code and corrective actions,

see the equipment's operating manual.

Flexi EDGE Flexi Multiradio:

Description: A fault is detected at the Ethernet SFP interface.

Instructions:

1. Check that the SFP module is correctly installed.

2. Check that the SFP module is of supported type (Ethernet 1000 Base-SX

  or 1000 Base-LX).

3. Check that the electrical contacts of the SFP module are clean from

  dust, dirt or water.

4. Replace the SFP module.

5. Replace FIxx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 466: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 466/486

466 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8282 PSEUDOWIRE TUNNEL DOWN

223 8282 PSEUDOWIRE TUNNEL DOWN

Meaning

Pseudowire tunnel is not functional. No pseudowire packets have arrivedfor the configured VLAN and pseudowire local/peer IP address pair for

one second.

Possible causes are that there are no pseudowires configured on the

peer IP, the local or peer IP/gateway configurations are incorrect,

the peer subnet mask is incorrect, the far-end ARP resolution for the

local IP address has failed, the VLAN configuration is incorrect, or

there is no physical connection.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies the physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 the number of the Q1 service channel in the BSC. The number can

  be 0...27. If the equipment is supervised by the BTS, the channel

  number is not relevant

6 the name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

7 the number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  For more information, see the alarm's instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

Page 467: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 467/486

DN998797 467

Transmission Equipment Alarms (8000-8999) 8282 PSEUDOWIRE TUNNEL DOWN

Id:0900d80580804c95

Confidential

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check the Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To find out the reason for the fault, open a remote session to the

transmission equipment and display the fault information.

For more detailed information on the fault code and corrective actions,

see the equipment's operating manual.

Flexi EDGE Flexi Multiradio:

Fault reason: Transmission is commissioned to be in Pseudowire (PWE)

mode without a licence.

Instructions:

  1. Install and activate the 'Flexi EDGE Abis over IP/

  Ethernet' licence at the BSC.

  2. Recommission the site to use TDM mode.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

Page 468: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 468/486

468 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8283 LICENCE FOR IP SECURITY IS NOT AVAIL- ABLE

224 8283 LICENCE FOR IP SECURITY IS NOT

AVAILABLE

Meaning

The feature cannot be activated without a licence.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical

  unit of the transmission equipment, for example a

  plug-in unit or a daughter board. The number can be

  0...254

4 the supervision block number specifies the faulty

  part of the functional entity, for example a certain

  line interface or component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 469: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 469/486

DN998797 469

Transmission Equipment Alarms (8000-8999) 8283 LICENCE FOR IP SECURITY IS NOT AVAIL- ABLE

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

Page 470: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 470/486

470 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8284 TRAFFIC SHAPING MISCONFIGURATION

225 8284 TRAFFIC SHAPING MISCONFIGURA-

TION

Meaning

Traffic shaping misconfigured. BTS-internal traffic shaping disabled but

Abis traffic shaping is enabled or CIR value of Abis traffic shaping is

smaller than CIR value of the BTS-internal uplink traffic shaping.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical

  unit of the transmission equipment, for example a

  plug-in unit or a daughter board. The number can be

  0...254

4 the supervision block number specifies the faulty

  part of the functional entity, for example a certain

  line interface or component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel  number is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 471: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 471/486

DN998797 471

Transmission Equipment Alarms (8000-8999) 8284 TRAFFIC SHAPING MISCONFIGURATION

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

The fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

Page 472: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 472/486

472 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8285 LICENCE FOR TIMING OVER PACKET IS NOT AVAILABLE

226 8285 LICENCE FOR TIMING OVER PACKET

IS NOT AVAILABLE

Meaning

The feature cannot be activated without a licence.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical

  unit of the transmission equipment, for example a

  plug-in unit or a daughter board. The number can be

  0...254

4 the supervision block number specifies the faulty

  part of the functional entity, for example a

  certain line interface or component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 473: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 473/486

DN998797 473

Transmission Equipment Alarms (8000-8999) 8285 LICENCE FOR TIMING OVER PACKET IS NOT AVAILABLE

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected. Alarm is cancelled when the

license for ToP clock is made available or Alarm is cancelled when

ToP clock is removed from the priority list.

Page 474: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 474/486

474 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8286 LICENCE FOR SYNCHRONOUS ETHERNET ISNOT AVAILABLE

227 8286 LICENCE FOR SYNCHRONOUS

ETHERNET IS NOT AVAILABLE

Meaning

The feature cannot be activated without a licence.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical

  unit of the transmission equipment, for example a

  plug-in unit or a daughter board. The number can be

  0...254

4 the supervision block number specifies the faulty

  part of the functional entity, for example a certain

  line interface or component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot  FF = not defined

Page 475: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 475/486

DN998797 475

Transmission Equipment Alarms (8000-8999) 8286 LICENCE FOR SYNCHRONOUS ETHERNET ISNOT AVAILABLE

Id:0900d80580804c95

Confidential

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected. Alarm is cancelled when the

license for SyncE clock is made available or Alarm is cancelled when

SyncE clock is removed from the priority list.

Page 476: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 476/486

476 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8287 CLOCK RECOVERY IN PROGRESS

228 8287 CLOCK RECOVERY IN PROGRESS

Meaning

BTS Timing over Packet Slave is running clock recovery algorithm andclock synchronisation is not yet complete

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical

  unit of the transmission equipment, for example a

  plug-in unit or a daughter board. The number can be

  0...254

4 the supervision block number specifies the

  faulty part of the functional entity, for example

  a certain line interface or component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel

  number is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object

  field of the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object

  field of the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised

  by a BTS that supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised

  by a BTS that supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by

Page 477: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 477/486

DN998797 477

Transmission Equipment Alarms (8000-8999) 8287 CLOCK RECOVERY IN PROGRESS

Id:0900d80580804c95

Confidential

  a BTS that supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether

the BSC or the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands

Axx for alarm administration.

If the BTS supervises the equipment, use the MML commands

EOx for alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed

information on the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected. Alarm is cancelled after ToP

clock gets the lock or Alarm is cancelled when 30 minute timer

expires. Alarm Error in Connection with ToP Master is raised and ToP

Clock is marked as Not OK.

Page 478: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 478/486

478 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8288 FAULT IN CONNECTION TO CLOCK MASTER

229 8288 FAULT IN CONNECTION TO CLOCK

MASTER

Meaning

Timing over Packet master is not reachable or unable to

provide required synchronisation messages

Notes: This alarm is masked if Loss of Synchronisation or Frequency error alarm is

raised.

Rationale is that if BTS switches to internal clock, there will be already these

alarms and user can determine if ToP is root cause by checking related status

display.

The alarm is raised when:1. The difference between expected sync message rate and

actual sync message rate is less than 50% within 10 seconds.

2. If the announce grant from the master is ignored for the first time after a

timeout period of 2 seconds.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical

  unit of the transmission equipment, for example a  plug-in unit or a daughter board. The number can

  be 0...254

4 the supervision block number specifies the faulty

  part of the functional entity, for example a certain

  line interface or component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined  Included only if the equipment is supervised by a BTS that

Page 479: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 479/486

DN998797 479

Transmission Equipment Alarms (8000-8999) 8288 FAULT IN CONNECTION TO CLOCK MASTER

Id:0900d80580804c95

Confidential

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether

the BSC or the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands

Axx for alarm administration.

If the BTS supervises the equipment, use the MML commands

EOx for alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed

information on the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected. Alarm is cancelled when ToP Clock

gets the lock or ToP Clock is removed from priority list.

Page 480: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 480/486

480 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8289 SSM HAS LOST TRACEABILITY TO PRCCLOCK SOURCE

230 8289 SSM HAS LOST TRACEABILITY TO PRC

CLOCK SOURCE

Meaning

Invalid clock quality level received

Notes: This alarm is masked if Loss of Synchronisation or Frequency error alarm is

raised.

Rationale is that if BTS switches to internal clock, there will be already these

alarms and user can determine if SSM is root cause by checking related status

display.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit of the

  transmission equipment, for example a plug-in unit or a

  daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part of the

  functional entity, for example a certain line interface or

  component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that  supports coordinate settings

Page 481: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 481/486

DN998797 481

Transmission Equipment Alarms (8000-8999) 8289 SSM HAS LOST TRACEABILITY TO PRCCLOCK SOURCE

Id:0900d80580804c95

Confidential

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the BSC or

the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands Axx for

alarm administration.

If the BTS supervises the equipment, use the MML commands EOx for

alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed information on

the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

Alarm is cancelled if SSM Operation is disabled or Alarm is

cancelled if SyncE Clock is deleted from Priority list or Alarm is

cancelled if SSM with QL PRC is received at the active SyncE port.

Page 482: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 482/486

482 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8290 LICENCE FOR PACKET TRS E1/T1 IS NOT AVAILABLE

231 8290 LICENCE FOR PACKET TRS E1/T1 IS

NOT AVAILABLE

Meaning

The feature cannot be activated without a licence.

This alarm affects the provided services.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit

  of the Transmission equipment, for example a plug-in

  unit or a daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part

  of the Functional entity, for example a certain line

  Interface or component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined  Included only if the equipment is supervised by a BTS that

Page 483: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 483/486

DN998797 483

Transmission Equipment Alarms (8000-8999) 8290 LICENCE FOR PACKET TRS E1/T1 IS NOT AVAILABLE

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the

BSC or the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands

Axx for alarm administration.

If the BTS supervises the equipment, use the MML commands

EOx for alarm administration.

To clarify the reason for the fault, take a remote session to

transmission equipment and display fault information.

See the equipment operating manual for more detailed

information on the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm

automatically when the fault has been corrected.

Page 484: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 484/486

484 DN998797

Transmission Equipment Alarms (8000-8999)

Id:0900d80580804c95

Confidential

8291 PMTU BTS TO BSC LESS THAN CONFIGRUEDMTU

232 8291 PMTU BTS TO BSC LESS THAN CONFI-

GRUED MTU

Meaning

Path MTU (PMTU) to BSC has been determined by BTS to be less than the

configured MTU value.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit

  of the transmission equipment, for example a plug-in

  unit or a daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part

  of the functional entity, for example a certain line

  interface or component

5 number of the Q1 service channel in the BSC, 0...27.

  If equipment is supervised by the BTS, the channel number

  is not relevant

6 name of the piece of transmission equipment.

  Not included if the name is in the alarm object field of

  the alarm printout.

  See alarm instructions

7 number of the piece of transmission equipment.

  Not included if the index is in the alarm object field of

  the alarm printout.

  See alarm instructions

8 rack (cabinet) number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

9 shelf number

  FF = not defined

  Included only if the equipment is supervised by a BTS that

  supports coordinate settings

10 slot

  FF = not defined

  Included only if the equipment is supervised by a BTS that

Page 485: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 485/486

DN998797 485

Transmission Equipment Alarms (8000-8999) 8291 PMTU BTS TO BSC LESS THAN CONFIGRUEDMTU

Id:0900d80580804c95

Confidential

  supports coordinate settings

Instructions

Check Supplementary information field 1 to see whether the

BSC or the BTS supervises the equipment.

If the BSC supervises the equipment, use the MML commands

Axx for alarm administration.

If the BTS supervises the equipment, use the MML commands

EOx for alarm administration.

To clarify the reason for the fault, take a remote session

to transmission equipment and display fault information.

See the equipment operating manual for more detailed

information on the fault code and corrective actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm

automatically when the fault has been corrected.

Page 486: 2G 8000 - 8999 Transmission Alarms

7/25/2019 2G 8000 - 8999 Transmission Alarms

http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 486/486

Transmission Equipment Alarms (8000-8999)8292 PMTU BTS TO SECURITY GATEWAY LESSTHAN CONFIGURED MTU

233 8292 PMTU BTS TO SECURITY GATEWAY

LESS THAN CONFIGURED MTU

Meaning

Path MTU (PMTU) to Security Gateway has been determined by BTS

to be less than the configured MTU value.

Supplementary information fields

1 01 BSC supervises the equipment

  02 BTS supervises the equipment

2 Q1 address of the piece of transmission equipment

3 the functional entity number specifies a physical unit

  of the transmission equipment, for example a plug-in unit

  or a daughter board. The number can be 0...254

4 the supervision block number specifies the faulty part

  of the functional entity, for example a certain line

  interface or component

5 number of the Q1 service channel in the BSC, 0...27.