2.motor starters - enclosed versions
TRANSCRIPT
2/0 Schneider Electric
Contents
2
2 - Motor starters - enclosed version
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 2/2
VARIO enclosed switch disconnectors# Pre-assembled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/4
# Assembled by user . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/5
# Add-on modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/6
Enclosed thermal-magnetic motor circuit-breakers# Type GV2-ME
5 Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/10
5 Assembly of a safety enclosure for safety applications . . . . . . . . . . . page 2/12
# Type GV3-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/11
D.O.L. starters for motor control# 0.55 to 30 kW
5 With manual control and with magnetic circuit breaker, . . . . . . . . . . . page 2/14
# 2.2 to 45 kW
5 Without isolating device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/16
5 With isolating device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/20
# 0.25 to 7.5 kW
5 With 3-phase thermal overload relay . . . . . . . . . . . . . . . . . . . . . . . . . page 2/24
# 0.37 to 5.5 kW
5 With thermal magnetic circuit-breaker and contactor . . . . . . . . . . . . . page 2/26
Star-delta starters for motor control# 5.5 to 132 kW
5 Without isolating device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/28
# 7.5 to 75 kW
5 With isolating device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/32
# 90 to 375 kW
5 Without isolator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/38
# For use on a machine subject to the application
of machinery directive 98/37/CE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 Non reversing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/62
5 Reversing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/64
5 Non reversing with integral transformer . . . . . . . . . . . . . . . . . . . . . . . page 2/68
5 Reversing with integral transformer . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/69
D.O.L. starters for control in category AC-1# Without isolator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/40
# With off-load isolator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/44
2/1Schneider Electric
2
integral 18, 32 and 63 contactor breakers and reversing contactor breakers# Enclosures and door interlock mechanisms for customer assembly . . . page 2/48
integral 32 and 63 contactor breakers and reversing contactor breakers# Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/54
# Door interlock mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/55
# For the control and protection of motors . . . . . . . . . . . . . . . . . . . . . . . . page 2/56
# For control and protection of resistive circuits in category AC-1 . . . . . . page 2/58
# Auxiliary contact blocks and accessories . . . . . . . . . . . . . . . . . . . . . . . page 2/59
Enclosed D.O.L. starters for AS-i bus# Models LF 1-M, LF2-M, LF1-P or LF2 -P . . . . . . . . . . . . . . . . . . . . . . . page 2/72
# Model LF7-P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/74
# Model LF8-P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/75
# Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/77
Interface modules LA9-Z # For D.O.L. starters for AS-i bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/91
0243Q-EN_Ver2.22.fm/2
General selection guide
TeSys enclosed starters 2
Applications D.O.L. starters
Type Standard starters Starters for safetyapplications
Standard power ratings 4…37 kW 0.06…45 kW 0.55…30 kW 0.37…5.5 kW 0.25…45 kW 2.2…45 kW 0.06…11 kWof 3-phase motors in AC-3 400/415 V
Starters
Manual p p p – – – p
Auto – – – p p p –
Isolation
Switch p – – – – – –
Circuit-breaker – p p p – – p
Disconnector – – – – – p –
Protection
Short-circuit – p p p – p p
Overload – p p p p p p
Communication – – – – – – –
References VpF GV2-ME GV2-LC LE1-GVME LE1-M LE4-K GV2-ME
Non reversing VCFN GV3-CE GV-NGC LE1-D LE4-D
VpFX
Reversing– – – – LE2-K LE8-K
LE8-D
LE2-D
–
LE2-D
Pages 23008/2 and 23008/3
80263/2 and 80263/3
24110/2 24111/2 24101/2, 24101/3 and 24105/2
24103/2 and 24103/3
21058/2 and 21058/3
(1) Please consult your Regional Sales Office.
Schneider Electric
Schneider Electric
2
Soft start units Variable speed controllers
AS-i bus Standard Electronicstarters star-delta soft start -
starters soft stop units
0.06…9 kW 0.06…9 kW 0.06…5.5 kW 5.5… 7.5… 0.37…11 kW 0.37…4 kW 0.75…75 kW132 kW 75 kW
– – – – – p (LH7-0M) p p
p p p p p p (LH7-KP) p p
p – – – – – p p (from 7.5 kW)
p p p – – p – p (up to 5.5 kW)
– – – – p – – –
p p p – p p p p
p p p p p p p p
– – p – – – – p
LG1-K LG7-K LF1-M LE3-K LE6-D LH7-0 ATV-28E ATV-58E
LG1-D LG7-D LF1-P LE3-D LE3-D LH7-K
LJ7-K LF7-P LE3-F (1)
– LG8-K LF2-M – – – ATV-28E ATV-58E
LJ8-K LF2-P
LF8-P
24026/3 24026/2 and 24026/4, 26044/2 and 26044/3
24084/2 to 24088/3
24106/2 and 24106/3
24108/2 and24108/3
24073/2 and 24073/3
(1)
0243Q-EN_Ver2.22.fm/3
23008_Ver3.10-EN.fm/2 Schneider Electric
Enclosed starters 2
VARIO enclosed switch disconnectors, pre-assembled
- 3-pole switch disconnectors, 10 to 140 A, rotary operator, conforming to IEC 947-4-1 and IEC 204.- Padlockable handle (padlocks not included).- IP 65 degree of protection enclosure, lead sealable and lockable.- Lockable cover in position “I” (ON) up to 63 A rating.- Marking on front plate
3-pole main and emergency stop switch disconnectors (1)
- 3-pole switch disconnectors, 10 to 32 A, rotary operator, conforming to IEC 947-4-1.- Degree of protection IP 55.
3-pole main and emergency stop switch disconnectors (1)
(1) For characteristics of switch disconnectors, please consult your Regional Sales Office.(2) For VCF and VBF enclosures, see page 23009/2. For VCFN enclosures, see page 23009/3.
Enclosed switch disconnectors for high performance applications
Operator Ithe Power Incorp- Possible Reference WeightHandle Front plate AC-23 orated attach-
Dimensions at 400 V switch ments body (2)
mm A kW kg
Red Yellow 10 4 V02 2 VCF-02GE 0.500Padlockable, 60 x 60up to 3 locks 16 5.5 V01 2 VCF-01GE 0.500(Ø 4 to 8 shank)
20 7.5 V0 2 VCF-0GE 0.500
25 11 V1 2 VCF-1GE 0.500
32 15 V2 2 VCF-2GE 0.500
50 22 V3 3 VCF-3GE 0.930
63 30 V4 3 VCF-4GE 0.930
Red cross Yellow 100 37 V5 1 VCF-5GE 2.190type 90 x 90Padlockable,up to 3 locks 140 45 V6 1 VCF-6GE 2.190(Ø 4 to 8 shank)
3-pole main stop switch disconnectors (1)
Black Black 10 4 V02 2 VBF-02GE 0.500Padlockable, 60 x 60up to 3 locks 16 5.5 V01 2 VBF-01GE 0.500(Ø 4 to 8 shank)
20 7.5 V0 2 VBF-0GE 0.500
25 11 V1 2 VBF-1GE 0.500
32 15 V2 2 VBF-2GE 0.500
50 22 V3 3 VBF-3GE 0.930
63 30 V4 3 VBF-4GE 0.930
Black cross Black 100 37 V5 4 VBF-5GE 2.190type 90 x 90Padlockable,up to 3 locks 140 45 V6 4 VBF-6GE 2.190(Ø 4 to 8 shank)
Enclosed switch disconnectors for standard applications
Red Yellow 10 4 VN-12 2 VCFN-12GE (2) 0.422Padlockable, 60 x 60either by 1 lock 16 5.5 VN-20 2 VCFN-20GE (2) 0.422(Ø 8 shank)or by 3 locks 20 7.5 V0 0 VCFN-25GE 0.512(Ø 6 shank)
25 11 V1 0 VCFN-32GE 0.512
32 15 V2 0 VCFN-40GE 0.512
References
VCF-0GE
VCF-3GE
VBF-0GE
VCFN-12GE
Dimensions :page 23010/2
Schemes :page 23010/3
23008_Ver3.10-EN.fm/3Schneider Electric
Enclosed starters 2
VARIO enclosed switch disconnectors, assembled by user
IP 65 enclosure with red padlockable handle operator and yellow front plate (for mounting a main or emergency stop switch disconnector)
(1) See pages 23009/2 and 23009/3.(2) For characteristics of switch disconnectors, please consult your Regional Sales Office.
Empty enclosures
For switch Ithe Possible Reference Weightbody attachments (1)
A kg
VN-12, VN-20 10…32 2 VCFX-GE1 0.340V02…V2
V02…V2 10…32 4 VCFX-GE4 0.660
V3 and V4 50…63 3 VCFX-GE2 0.660
4 VCFX-GDXE 0.660
IP 65 enclosure with black padlockable handle and black front plate (for mounting main stop switch disconnector) For switch Ithe Possible Reference Weightbody attachments (1)
A kg
VN-12, VN-20 10…32 2 VBFX-GE1 0.340V02…V2
V02…V2 10…32 4 VBFX-GE4 0.660
V3 and V4 50…63 3 VBFX-GE2 0.660
4 VBFX-GDXE 0.660
Switch bodies for standard applications (2)
Description Rating Reference WeightA kg
3-pole switch disconnectors 10 VN-12 0.110
16 VN-20 0.110
Switch bodies for high performance applications (2)
Description Rating Reference WeightA kg
3-pole switch disconnectors 10 V02 0.200
16 V01 0.200
20 V0 0.200
25 V1 0.200
32 V2 0.200
50 V3 0.200
63 V4 0.200
References
VBFX-GE2
V0
Dimensions :pages 23010/2 and 23010/3
Schemes :page 23010/3
23009_Ver2.10-EN.fm/2 Schneider Electric
1 add-on module on each side of the switch body.
2 add-on modules on each side of the switch body.
Note: The add-on modules mounted next to the switch body are main poles. Maximum of 3 main poles per switch body.(1) Late make N/O contact, early break N/C contact
Add-on modules for enclosures VCF and VBF
Description Rating Reference WeightA kg
Main pole module 10 VZ-02 0.050(mounted in enclosure)
16 VZ-01 0.050
20 VZ-0 0.050
25 VZ-1 0.050
32 VZ-2 0.050
50 VZ-3 0.100
63 VZ-4 0.100
Neutral pole modules 10 to 32 VZ-11 0.050with early make andlate break contacts 50 and 63 VZ-12 0.100
100 and 140 VZ-13 0.250
Earthing modules 10 to 32 VZ-14 0.050
50 and 63 VZ-15 0.100
100 and 140 VZ-16 0.250
Auxiliary contact block modules N/O + N/C (1) VZ-7 0.050with 2 auxiliary contacts
N/O + N/O VZ-20 0.050
Maximum number of add-on modules which can be fitted on a switch body
VZ-7 or VZ-20 + V0 + VZ-7 or VZ-20
or or
VZ-11 or VZ-12 +V0
+ VZ-11 or VZ-12
or or
VZ-14 or VZ-15 + to + VZ-14 or VZ-15
orV4
or
VZ-0//VZ-0 to VZ-4 + + VZ-0//VZ-0 to VZ-4
VZ-0/ + VZ-0/ + V0/ + VZ-0/ + VZ-7 or VZ-20 or VZ-11 or VZ-14
VZ-0 + VZ-0 + V0 + VZ-0 + VZ-7 or VZ-20 or VZ-11 or VZ-14
VZ-1 + VZ-1 + V1 + VZ-1 + VZ-7 or VZ-20 or VZ-11 or VZ-14
VZ-2 + VZ-2 + V2 + VZ-2 + VZ-7 or VZ-20 or VZ-11 or VZ-14
VZ-3 + VZ-3 + V3 + VZ-3 + VZ-7 or VZ-20 or VZ-12 or VZ-15
VZ-4 + VZ-4 + V4 + VZ-4 + VZ-7 or VZ-20 or VZ-12 or VZ-15
Enclosed starters 2
VARIO enclosed switch disconnectorsAdd-on modules
References
VZ-11VZ-0
VZ-20VZ-15
Schemes :page 23010/3
23009_Ver2.10-EN.fm/3Schneider Electric
Enclosed starters 2
VARIO enclosed switch disconnectorsAdd-on modules
Add-on modules for enclosures VCFN-12GE and 20GE
Description Rating Reference WeightA kg
Main pole module 10 VZN-12 0.020
16 VZN-20 0.020
Neutral pole module with early 10 and 16 VZN-11 0.020make and late break contacts
Earthing module 10 and 16 VZN-14 0.016
Auxiliary contact block module 1 late make N/O contact VZN-05 0.020
1 early break N/C contact VZN-06 0.020
Maximum number of add-on modules which can be fitted on switch body
VZN-12 or VZN-20 + + VZN-12 or VZN-20
VN-12 or
or VZN-11
or VN-20 or
VZN-05 or VZN-06
or
VZN-05 or VZN-06 VZN-14
References
VZN-11
VZN-14
VZN-05
Schemes :page 23010/3
23010_Ver2.10-EN.fm/2 Schneider Electric
82,5106
131
90
==
c
c1
b
a
= =
H
126
191
190
220
201
=
=
280
Enclosed starters 2
VARIO enclosed switch disconnectors
VCFN-12GE to VCFN-40GE
VCF or VBF-5GE and 6GE
Cable glands: 2 x 16 P top and bottom
VCF or VBF-02GE to 4GEVCFX or VBFX-GE1 to GE4
a b c c1 HV/F-02GE to V/F-2GE, V/FX-GE1 (1) 90 146 85 131 130V/F-3GE and V/F-4GE (2) 150 170 106 152 164V/FX-GE2 and V/FX-GE4 (2) 150 170 106 152 164
(1) Cable glands 2 x 16 P top and bottom(2) Cable glands 2 x 16/21/29 P top and bottom
Dimensions
References :page 23008/2
Schemes :page 23010/3
23010_Ver2.10-EN.fm/3Schneider Electric
1/
L12/
T1
3/L2
4/T
2
5/L3
6/T
3
222113
14
1314 24
23
1314 22
21
86
162
130
168
180
=
=
220
Enclosed starters 2
VARIO enclosed switch disconnectors, for customer assembly
Empty enclosuresVCFX or VBFX-GDXE
Schemes
Auxiliary contact blocks
Switch disconnectors Main pole Neutral poleenclosed module moduleor switch bodies
VZ-7 VZ-20 VZN-05 VZN-06
Dimensions
References :page 23008/3
24720-EN_Ver1.0.fm/2 Schneider Electric
TeSys enclosed starters 2
Enclosed thermal-magnetic motor circuit-breakerstype GV2-ME and accessories,for customer assembly
Motor circuit-breakers and accessories : see pages 24508/3, 24512/3 and 24512/9.Starters consisting of an enclosed motor circuit-breaker GV2-ME conform to IEC 947-4-1.
Ithe enclosed
(1) Enclosure GV2-MCK04 has a mushroom head Stop pushbutton GV2-K04 fitted as standard.(2) Supplied with IP 55 sealing kit. To be fitted with GV2-Mp01.(3) Padlocking in the “O” position by padlock with Ø 4 to 8 mm shank.
Thermal-magnetic motor circuit-breakers GV2-ME
GV2- ME01 ME02 ME03 ME04 ME05 ME06 ME07 ME08 ME10 ME14 ME16 ME20 ME21 ME22
(A) 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 9 13 17 21 23
Enclosures for thermal-magnetic motor circuit-breakers GV2-ME
Type Degree of protection Max. no. of side mounted Reference Weightcontacts on GV2-MELH RH kg
Surface IP 41 1 1 GV2-MC01 0.290mounting,double insulatedwith protective IP 55 1 1 GV2-MC02 0.300conductor. or GV2-MCK04 (1) 0.420Sealablecover IP 55 for 1 1 GV2-MC03 0.300
temperature < + 5 °C
Flush IP 41 (front face) 1 1 GV2-MP01 0.115mountingwith protectiveconductor IP 41 (reduced – 1 GV2-MP03 0.115
flush mounting)
IP 55 (front face) 1 1 GV2-MP02 0.130
IP 55 (reduced – 1 GV2-MP04 0.130flush mounting)
GV2-MC
5002
77_1
GV2-MP
5002
80_
1
Front plate
For direct control, through a panel, IP 55 GV2-CP21 0.800of a chassis mounted GV2-ME
GV2-CP
5002
78_
1
Accessories common to all enclosures (to be ordered separately)
Description Sold in Unit Weightlots of reference kg
Padlocking kit (2) 1 to 3 padlocks 1 GV2-V01 0.075for GV2-ME operator (padlocking is Ø 4 to 8 mmonly possible in the “O” position)
Mushroom Spring return (2) 1 GV2-K011 0.052headStoppushbutton Latching (2) Key release 1 GV2-K021 0.160Ø 40 mm, IP 55 (key n° 455)red
Turn to 1 GV2-K031 0.115release
1 GV2-K04 (3) 0.120
Sealing For enclosures IP 55 10 GV2-E01 0.012kit and front plates
IP 55 10 GV2-E02 0.012for θ < + 5 °C
Neutral link 100 AB1-VV635UBL 0.015
Cover 50 AB1-AC6BL 0.003
GV2-K011
500
279_
1References
24720-EN_Ver1.0.fm/3Schneider Electric
TeSys enclosed starters 2
Enclosed thermal-magnetic motor circuit-breakerstype GV3-M and accessories,for customer assembly
Motor circuit-breakers and accessories : see pages 24508/5 and 24512/5.GV3-ME40 : operational current in enclosure limited to 30 A.Starters consisting of an enclosed GV3-ME conform to IEC 947-4-1.
(1) Spare part.
Thermal-magnetic motor circuit-breakers GV3-ME
Metal enclosure for thermal-magnetic circuit-breakers GV3-ME
Application Type Degree of protection Reference Weightof enclosure kg
Motor Surface mounting IP 55 GV3-CE01 2.000circuit-breakerup to 30 Awith or withoutaccessoriesGV3-CE01
8122
18
Enclosure accessories (to be ordered separately)
Description Sold in Unit Weightlots of reference kg
Sealing For θ ≥ 5 °C 10 GV1-EA01 0.012membrane (1)
For θ < 5 °C (silicone) 10 GV1-EA02 0.012
IP 55 padlocking device for operators(when padlocked, the motor circuit is automaticallyin the Open (OFF) position)
1 GV1-V01 0.044
Stop pushbutton Spring return 1 GV1-K01 0.052Ø 40 mm, redmushroom head(supplied with IP 55sealing kit)
Latching Key release 1 GV1-K02 0.095(key n° 455)
Turn 1 GV1-K03 0.052to release
GV1-V01
812
219
GV1-K01
8122
20
References
21058-EN_Ver2.1.fm/2
References TeSys enclosed starters 0
Enclosed thermal-magnetic motor circuit-breakers type GV2 ME and accessoriesAssembly of a safety enclosure
Thermal-magnetic motor circuit-breakers GV2 MEFor motor circuit-breakers and accessories: see pages 24508/3, 24512/2 and 24512/3. Starters consisting of a GV2 ME motor circuit-breaker in an enclosure conform to standard IEC 60947-4-1.
GV2 ME 01
ME 02
ME 03
ME 04
ME 05
ME 06
ME 07
ME 08
ME 10
ME 14
ME 16
ME 20
ME 21
ME 22
Ithe in enclosure (A)
0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 9 13 17 21 23
Enclosures for thermal-magnetic circuit-breakers GV2 METype Degree of
protectionPossible number ofside-mounting auxiliary contact blocks on GV2 ME
Reference Weight
LH side RH side kgSurface mounting, double insulated with protective conductor. Sealable cover
IP 41 1 1 GV2 MC01 0.290
IP 55 1 1 GV2 MC02 0.300
or GV2 MCK04 (1) 0.420
IP 55 for temperature < + 5 °C
1 1 GV2 MC03 0.300
Accessories common to all enclosures (to be ordered separately)Description Sold in
lots ofUnit reference
Weightkg
Padlocking devices (2) for GV2 ME operator (padlocking is only possible in the “O” position)
1 to 3 padlocks Ø 4 to 8 mm
1 GV2 V01 0.075
Mushroom head “Stop” pushbutton Ø 40 mm, red
Spring return (2) 1 GV2 K011 0.052
Latching (2)IP 55
Key release, key n° 455
1 GV2 K021 0.160
Turn to release
1 GV2 K031 0.115
1 GV2 K04 (3) 0.120
Sealing kit For enclosures and front plate
IP 55 for temperature between + 5 °C and + 40 °C
10 GV2 E01 0.012
IP 55 for temperature between - 20 °C and + 40 °C
10 GV2 E02 0.012
Neutral terminal
100 AB1 VV635UBL 0.015
Partition 50 AB1 AC6BL 0.003
(1) Enclosure GV2 MCK04 is fitted with a GV2 K04 mushroom head “Stop” pushbutton as standard.
(2) Supplied with IP 55 sealing kit. To be fitted with enclosure GV2 Mp01.(3) Padlockable in “Off” position using Ø 4 to 8 mm shank padlocks.
GV2 MC
500
277_
1
GV2 K011
5002
79_1
21058-EN_Ver2.1.fm/3
References (continued) TeSys enclosed starters 0
Enclosed thermal-magnetic motor circuit-breakers type GV2 ME and accessoriesAssembly of a safety enclosure
Assembly of a safety enclosure(conforming to standards IEC 60974-4-1, IEC 60204 and IEC 60292)
Type of product Page Reference
Enclosure Opposite GV2 MCpp
Circuit-breaker 24508/2 GV2 MEpp
Undervoltage trip or INRS trip (1) 24512/3 GV2 Apppp
or GV2 AXppp
Latching mushroom head “Stop” pushbutton
Opposite GV2 K021or GV2 K031or GV2 K04
(1) Safety device for dangerous machines conforming to INRS and VDE 0113.
24110-EN_Ver2.11.fm/2 Schneider Electric
TeSys enclosed starters 2
D.O.L. starters with manual control,with magnetic circuit breaker, 0.55 to 30 kW
Control by black rotary handle, padlockable in Off position (up to 3 padlocks with Ø 8 shank, to be ordered separately)
Starters with control by red rotary handle on yellow background
Add the letter R to the end of the references selected above. Example: GV2-LC0206 becomes GV2-LC0206R.
Enclosure without circuit-breaker, with rotary handle mounted on cover
(1) Circuit-breaker characteristics: - GV2-L see pages 24523/2 and 24523/3- NG 125L, product marketed under the Merlin Gerin, brand, please consult your Regional Sales Office.
(2) Avoid placing this material in contact with harsh substances (detergents, chlorinated solvents, ketones, alcohol,aromatic hydrocarbons).
Characteristics (1)
Conforming to standards IEC 60947-4, IEC 60439-1, VDE 0660-102 and EN 60947Degree of protection to IEC 60529 GV2-LC: IP 547, GV-NGC: IP 407Operational voltage Ue GV2-LC: 690 V, GV-NGC: 500 VMaterial Polycarbonate (2)
References
Rating Breaking capacity Icu Magnetic Reference WeightIn conforming to IEC 60947-2 tripping
220 400 current230 V 415 V 440 V 500 V Id ± 20 %
A kA kA kA kA A kg
1.6 100 100 100 100 13 In GV2-LC0206 0.780
2.5 100 100 100 100 13 In GV2-LC0207 0.780
4 100 100 100 100 13 In GV2-LC0208 0.780
6.3 100 100 100 100 13 In GV2-LC0210 0.780
10 100 100 20 10 13 In GV2-LC0214 0.780
14 100 50 20 10 13 In GV2-LC0216 0.780
18 100 50 20 10 13 In GV2-LC0220 0.780
25 100 50 30 15 12 In GV-NGC0225 2.450
32 100 50 30 15 12 In GV-NGC0232 2.450
40 100 50 30 15 12 In GV-NGC0240 2.450
50 100 50 30 15 12 In GV-NGC0250 2.450
63 100 50 30 15 12 In GV-NGC0263 2.450
Variant
Description Rating Reference WeightA kg
Black rotary handle 1.6…18 GV2-LC02 0.300
25…63 GV-NGC02 0.550
Red rotary handle 1.6…18 GV2-LC02R 0.300on yellow background
25…63 GV-NGC02R 0.550
Characteristics, references
GV2-LC02
GV2-LC02pp
GV-NGC02pp
Dimensions :page 24110/3
Schemes :page 24110/3
24110-EN_Ver2.11.fm/3Schneider Electric
348
330
==
=167
237 186,3
=
2/T
1
4/T
2
6/T
3
1/L1
3/L2
5/L3
120
173
166
15065
==
=
88
=
TeSys enclosed starters 2
D.O.L. starters with manual control,with magnetic circuit-breaker. 0.55 to 30 kW
Dimensions
Knock-outs or blanking plugs for cable glands
Scheme
GV2-LC0206 to LC0220 GV-NGC0225 to NGC0263
Type of enclosure At top At bottomPG ISO PG ISO
GV2-LC 2 x 13 to 2 x 16 2 x 20 I 2 x 13 or 2 x 16 2 x 20 I
GV-NGC 2 x 13 or 2 x 16 or 2 x 20 I or 2 x 25 I or 2 x 13 or 2 x 16 or 2 x 20 I or 2 x 25 I or2 x 21 or 2 x 29 2 x 32 I or 2 x 40 I 2 x 21 or 2 x 29 2 x 32 I or 2 x 40 I
Dimensions, scheme
References :page 24110/2
24101_Ver3.01-EN.fm/2 Schneider Electric
TeSys enclosed starters 2
D.O.L. starters for motor control (1)
2.2 to 45 kW, without isolating device
Non-reversing starters
(1) Protection must be provided by addition of an overload relay, to be ordered separately, see pages 24514/2 and 24514/3.(2) Avoid placing this material in contact with harsh substances (detergents, chlorinated solvents, ketones, alcohol,aromatic hydrocarbons).(3) Standard control circuit voltages.
Other voltages: please consult your Regional Sales Office. (4) Selection according to the number of operating cycles, please consult your Regional Sales Office.
Characteristics
Conforming to standards IEC 947-4-1 and IEC 439-1, VDE 0660-102, EN 60947
Degree of protection to IEC 529 IP 659: LE2-K, IP 657: LE/-D09 to D35 and IP 557: LE/-D405 to D955
Ambient air temperature For operation: - 5 to + 40 °C
Operating positions Identical to positions for contactors
Material Polycarbonate (2): LE2-K and LE/-D09 to D35. Sheet steel: LE/-D405 to D955
References
Standard power ratings of 3-phase Maximum Basic reference. Weightmotors 50/60 Hz in category AC-3 current Complete with code220 V 380 V 660 V I the indicating control Standard230 V 400 V 415 V 440 V 500 V 690 V up to circuit voltage (3) voltageskW kW kW kW kW kW A kg
2.2 4 4 4 5.5 5.5 9 LE1-D09// F7 P7 V7 0.920
3 5.5 5.5 5.5 7.5 7.5 12 LE1-D12// F7 P7 V7 0.920
4 7.5 9 9 10 10 18 LE1-D18// F7 P7 V7 1.015
5.5 11 11 11 15 15 25 LE1-D25// F7 P7 V7 1.015
7.5 15 15 15 18.5 18.5 35 LE1-D35// F7 P7 V7 4.320
11 18.5 22 22 22 30 40 LE1-D405// F7 P7 V7 4.820
15 22 25 30 30 33 50 LE1-D505// F7 P7 V7 4.850
18.5 30 37 37 37 37 65 LE1-D655// F7 P7 V7 4.850
22 37 45 45 55 45 80 LE1-D805// F7 P7 V7 5.140
25 45 45 45 55 45 95 LE1-D955// F7 P7 V7 5.440
Reversing starters
1.5 2.2 2.2 3 – – 6 LE2-K065// F7 P7 V7 1.080
2.2 4 4 4 – – 9 LE2-K095// F7 P7 V7 1.080or LE2-D09// (4) F7 P7 V7 2.100
– – – – 5.5 5.5 9 LE2-D09// F7 P7 V7 2.100
3 5.5 5.5 5.5 7.5 7.5 12 LE2-D12// F7 P7 V7 2.100
4 7.5 9 9 10 10 18 LE2-D18// F7 P7 V7 2.410
5.5 11 11 11 15 15 25 LE2-D25// F7 P7 V7 2.570
7.5 15 15 15 18.5 18.5 35 LE2-D35// F7 P7 V7 4.100
11 18.5 22 22 22 30 40 LE2-D405// F7 P7 V7 5.270
15 22 25 30 30 33 50 LE2-D505// F7 P7 V7 5.470
18.5 30 37 37 37 37 65 LE2-D655// F7 P7 V7 5.470
22 37 45 45 55 45 80 LE2-D805// F7 P7 V7 6.700
25 45 45 45 55 45 95 LE2-D955// F7 P7 V7 7.000
LE1-D12//
8101
7381
0174
LE2-D12//
Volts " 50/60 Hz 24 42 48 110 115 220 230 240 380 400 415 440LE2-K B7 D7 E7 F7 – M7 P7 U7 Q7 V7 N7 R7LE1, LE2-D B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7
Characteristics,references
Dimensions:page 24102/2
Schemes:page 24102/3
24101_Ver3.01-EN.fm/3Schneider Electric
TeSys enclosed starters 2
D.O.L. starters for motor control (1) 2.2 to 45 kW, without isolating device
Standard versions comprise:
1 red Stop/Reset button “O”
(1) See previous page.(2) Example: LE1-D09F7A04.
Description
/ For non-reversing starters: 1 green Start button “I”,1 red Stop/Reset button “O”.
/ For reversing starters:- LE2-K: 1 Start button ,
1 Start button ,1 red Stop/Reset button.
- LE2-D09 to D35: 1 2-position spring return selector switch “I”-“II”,1 red Stop/Reset button “O”.
- LE2-D405 to D955: 1 blue Reset button “R”.
Variants (pre-assembled)
Description Application Suffix to beadded to the starter reference (2)
No pushbuttons on cover LE1-D09…D955 A04LE2-D09…D955
1 green Start button “I” LE2-D405…D955 A111 green Start button “II”
1 blue Reset button “R” LE1-D09…D955 A05LE2-K06 and K09LE2-D09…D35
1 3-position stay put selector switch (“I”-“O”-“II”) LE1-D09…D35 A09(“I”: Automatic Start; “O”: Stop; “II”: Manual Start)1 blue Reset button “R”
1 2-position stay put selector switch “O”-“I” LE1-D09…D35 A13(“O”: Stop; “I”: Manual Start)1 blue Reset button “R”
1 3-position stay put selector switch “O”-“I” with LE1-D09…D35 A35spring return to centre position (“I”: Manual start; “O”: Stop, stay put)1 blue Reset button “R”
1 neutral terminal LE1-D09…D955 A59Fitted as standard on LE1 and LE2-D18 to D955 LE2-K06 and K09starters ordered with 220 V (M7), 230 V (P7) LE2-D09…D955or 240 V (U7) control supply
LE1-D12//A04
8101
75
LE1-D12//A05
8101
76
LE1-D12//A09
8101
77
LE1-D12//A13
8101
78
LE1-D12//A35
8101
78
Accessory (for customer assembly)
Description Application Reference Weightkg
Start pushbutton latching device LE1-D405…D955 LA9-D09907 0.060for stay put operation(Start-Stop)
Other versions Possible combinations of 2 variants.Please consult your Regional Sales Office.
References
Schemes:page 24102/3
24102_Ver2.10-EN.fm/2 Schneider Electric
287
c1 =
367
= 225
195
==
146
120
84
175
150
165
19
c1
307
=
257
= 165
165
==
c1
166
150
==
=
88
=c1
183
= =
101
201
c1
312
=
181
= 105
195
==
LE2-D405 to D655
Knock-outs or blanking plugs for cable glands
LE1-D09 and D12 LE1-D18 to D35 LE1-D405 to D655LE2-D09 to D35
c1 c1 c1LE1-D LE2-D
Standard version 128.5 Standard version 153.5 160 Standard version 161Version A04 120 Version A04 145 145 Version A04 150Version A05 128.5 Version A05 153.5 153.5 Version A05 161Version A09 135 Version A09 160 –Version A13 135 Version A13 160 –Version A35 135 Version A35 160 –LE2-K06 and K09
LE1-D805 and D955 LE2-D805 and D955
c1 c1LE1-D LE2-D
Standard version 176 176 Standard version 194Version A04 165 165 Version A04 190Version A05 176 – Version A05 194Version A11 – 176
Type of enclosure At top At bottomPG ISO PG ISO
LE1-D09 and D12 2 x 13 or 2 x 16 2 x 20 I 2 x 13 or 2 x 16 2 x 20 I
LE1-D18 to D35 and LE2-D09 to D35 2 x 16 or 2 x 21 2 x 20 I or 2 x 25 I 2 x 16 or 2 x 21 2 x 20 I or 2 x 25 I
LE2-D405 1 x 13 and 1 x 21 1 x 20 I and 1 x 25 I 1 x 13 and 2 x 21 1 x 20 I and 2 x 25 I
LE1-D405 to D655 and LE2-D505 and D655 1 x 13 and 1 x 29 1 x 20 I and 1 x 32 I 1 x 13 and 2 x 29 1 x 20 I and 2 x 32 I
LE1 or LE2-D805 and D955 1 x 13 and 1 x 36 1 x 20 I and 1 x 40 I 1 x 13 and 2 x 36 1 x 20 I and 2 x 40 I
LE2-K 2 x 13 and 2 x 16 4 x 20 I 2 x 13 and 2 x 16 4 x 20 I
TeSys enclosed starters 2
D.O.L. starters for motor control2.2 to 45 kW, without isolating device
Dimensions
References : pages 24101/2 and
24101/3Schemes :
page 24101/3
24102_Ver2.10-EN.fm/3Schneider Electric
– KM1 – KM2
L1 L2 L3
U V W
– KM2
A
B
– KM1
– KM2– KM1
– KM2 – KM1
A1
A2
A1
A2
O
B
– KM2– KM1
– KM2 – KM1
A1
A2
A1
A2
A
R
– KM1 – KM2
L1 L2 L3
U V W
L1 L2
– KM1
U V WL3
B
A
A1
A2
– KM1
– KM1
O
I
1314
2122
A
O
l – KM1
B
A1
A2
– KM1
A1
A2
– KM1
– KM2
– KM2
A
A1
A2
– KM2
– KM1
B
– KM1
– S1III
– KM2
A1
A2
– KM1
2122
– KM2
A
O
A1
A2
– KM2
– KM1
B
R
l l l
– KM1
LE1-D09 to D955 LE1-D09 to D955 Variant A04 or A05
LE2-K06, K09 LE2-K06, K09 Variant A05
LE2-D09 to D955 LE2-D09 to D35 LE2-D405 to D955LE2-D09 to D955 with variants A04 or A05
Connections A B220 V, 230 V, 240 V LE2-K, LE1 and LE2-D09 and D12 L3 Neutral
LE1 and LE2-D18 to D955 L3 Neutral terminal380 V, 400 V, 415 V, 440 V All products L3 L1Other voltages LE1 and LE2-D09 to D35 Terminal 1 Terminal 2
LE2-K, LE1 and LE2-D405 and D955 Direct connection
TeSys enclosed starters 2
D.O.L. starters for motor control2.2 to 45 kW, without isolating device
Schemes
References : pages 24101/2 and
24101/3Dimensions :
page 24102/2
Remote control
Remote control
Remote control
24103_Ver4.10-EN.fm/2 Schneider Electric
TeSys enclosed starters 2
D.O.L. starters for motor control (1)2.2 to 45 kW, with isolating device
Non-reversing starters
Reversing starters
(1) Protection must be provided by addition of an overload relay, to be ordered separately, see pages 24514/2 and 24514/3.(2) Avoid placing this material in contact with harsh substances (detergents, chlorinated solvents, ketones, alcohol,aromatic hydrocarbons).(3) Standard control circuit voltages.
Other voltages : please consult your Regional Sales Office.(4) Selection according to dimensions and number of operating cycles, please consult your Regional Sales Office.(5) Supplied with 3 cable entries.
Characteristics
Conforming to standards IEC 947-4-1 and IEC 439-1, VDE 0660-102, EN 60947
Degree of protection to IEC 529 IP 659 : LE/-K, IP 657 : LE/-D09 to D35 and IP 55 : LE/-D406 to D806
Ambient air temperature For operation : - 5 to + 40 °C
Operating positions Identical to positions for contactors
Material Polycarbonate (2) : LE/-K and LE/-D09 to D35. Sheet steel : LE/-D406 to D806
References
Standard power ratings of 3-phase Current Fuses Basic reference. Weightmotors 50/60 Hz in category AC-3 I the to be fitted by Complete with code 220 V 380 V 660 V max. the customer indicating control Standard230 V 400 V 415 V 440 V 500 V 690 V up to Size Type aM circuit voltage (3) voltageskW kW kW kW kW kW A A kg
1.5 2.2 2.2 3 – – 6 10 x 38 10 LE4-K065// F7 P7 V7 1.4502.2 4 4 4 – – 9 10 x 38 12 LE4-K095// F7 P7 V7 1.450
or LE4-D09// (4) F7 P7 V7 1.960
2.2 4 4 4 5.5 – 9 10 x 38 12 LE4-D09// F7 P7 V7 1.960
3 5.5 5.5 5.5 7.5 – 12 10 x 38 16 LE4-D12// F7 P7 V7 1.960
4 7.5 9 9 10 – 18 10 x 38 20 LE4-D18// F7 P7 V7 2.200
5.5 11 11 11 15 – 25 10 x 38 25 LE4-D25// F7 P7 V7 2.200
7.5 15 15 15 18.5 18.5 35 14 x 51 32 LE4-D35// F7 P7 V7 5.190
11 18.5 22 22 22 30 40 14 x 51 40 LE4-D406// F7 P7 V7 5.770
15 22 25 30 30 33 50 22 x 58 63 LE4-D506// F7 P7 V7 6.440
18.5 30 37 37 37 37 65 22 x 58 80 LE4-D656// F7 P7 V7 6.670
22 37 45 45 55 45 80 22 x 58 80 LE4-D806// (5) F7 P7 V7 7.100
1.5 2.2 2.2 3 – – 6 10 x 38 10 LE8-K065// F7 P7 V7 1.6002.2 4 4 4 – – 9 10 x 38 12 LE8-K095// F7 P7 V7 1.600
or LE8-D09// (4) F7 P7 V7 3.550
– – – – 5.5 – 9 10 x 38 12 LE8-D09// F7 P7 V7 3.550
3 5.5 5.5 5.5 7.5 – 12 10 x 38 16 LE8-D12// F7 P7 V7 3.550
4 7.5 9 9 10 – 18 10 x 38 20 LE8-D18// F7 P7 V7 3.700
5.5 11 11 11 15 – 25 10 x 38 25 LE8-D25// F7 P7 V7 4.670
7.5 15 15 15 18.5 18.5 35 14 x 51 32 LE8-D35// F7 P7 V7 5.800
11 18.5 22 22 22 30 40 14 x 51 40 LE2-D406// F7 P7 V7 14.170
15 22 25 30 30 33 50 22 x 58 63 LE2-D506// F7 P7 V7 14.700
18.5 30 37 37 37 37 65 22 x 58 80 LE2-D656// F7 P7 V7 14.770
22 37 45 45 55 45 80 22 x 58 80 LE2-D806// F7 P7 V7 16.000
Volts " 50/60 Hz 24 42 48 110 115 220 230 240 380 400 415 440LE/-K B7 D7 E7 F7 – M7 P7 U7 Q7 V7 N7 R7LE/-D B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7
Characteristics, references
LE4-D12//
Dimensions :page 24104/2
Schemes :page 24104/3
LE8-D12//
24103_Ver4.10-EN.fm/3Schneider Electric
TeSys enclosed starters 2
D.O.L. starters for motor control (1) 2.2 to 45 kW, with isolating device
Standard versions comprise :
(1) See previous page(2) Example : LE4-D09F7A04.
Description
/For non-reversing starters :- LE4-K and LE4-D09 to D656 : 1 green Start button “I”,
1 red Stop/Reset button “O”,
- LE4-D806 : no pushbuttons on cover.
/ For reversing starters :- LE8-K : 1 Start button ,
1 Start button ,1 red Stop/Reset button,
- LE8-D09 to D35 : 1 2-position spring return selector switch “I” “II”,1 red Stop/Reset button “O”,
- LE2-D406 to D806 : no pushbuttons on cover.
Protection Power circuit Control circuitLE4 and LE8-K 1 3-pole isolating device NoneLE4 and LE8-D09 to D35 1 3-pole isolating device + 1 additional pole LA8-D254LE4 and LE2-D406 to D806 1 3-pole isolating device + 1 circuit-breaker GB2-CB08
Variants (pre-assembled)
Description Application Suffix to beadded to thestarter reference (2)
No pushbuttons on cover LE4-D09…D656 A04LE8-D09…D35
1 green Start button “I” LE2-D406…D806 A111 green Start button “II”1 red Stop/Reset button “O”
1 blue Reset button “R” LE4-D09…D806 A05LE8-K06 and K09LE8-D09…D35LE2-D406…D806
1 neutral terminal LE4-K06 and K09 A59Fitted as standard on starters LE4-D18 to D806, LE4-D09…D806LE8-D18 to D35 and LE4-D406 to D806 LE8-K06 and K09ordered with 220 V (M7), 230 V (P7) and 240 V (U7) LE8-D09…D35control supply LE2-D406…D806
Accessories (for customer assembly)
Description Application Reference Weightkg
Start pushbutton latching device LE4-D406…D656 LA9-D09907 0.060for stay put operation(Start-Stop)
Other versions Possible combinations of 2 variants.Please consult your Regional Sales Office.
References
Schemes :page 24104/3
LE4-D12//A04
LE4-D12//A05
24104_Ver2.10-EN.fm/2 Schneider Electric
c1
20 84
17515
0
165
(1)
120
19
31
c1
348
330
==
=
186 31
=
287
c1 =
367
=
31
225
195
==
400
(1)
202
c1
== a-75
a-50
a
a+57,5
350
342,
5
325
==
4xM8x25
31
TeSys enclosed starters 2
D.O.L. starters for motor control2.2 to 45 kW, with isolating device
(1) For LE8 only.LE4-D406 to D656
LE2-D406 to D806LE4-D806
(1) + 14 mm with blanking plugs.
Knock-outs or blanking plugs for cable glands
LE4-K06 and K09 LE4-D09 to D35LE8-K06 and K09 LE8-D09 to D35
c1 c1LE4-K LE8-K LE4-D LE8-D
Standard version 146 146 Standard version 175.5 182Version A05 – 139 Version A04 167 167
Version A05 175.5 175.5
c1Standard version 201Version A04 190Version A05 201
LE2- aD406, D506, D656 300D806 400
LE4- aD806 400
c1LE2-D LE4-D
Standard version 218 218Version A05 218 218Version A11 – 218
Type of enclosure At top At bottomPG ISO PG ISO
LE4 and LE8-D09 to D35 2 x 13 or 2 x 16 or 2 x 20 I or 2 x 25 I or 2 x 13 or 2 x 16 or 2 x 20 I or 2 x 25 I or2 x 21 or 2 x 29 2 x 32 I or 2 x 40 I 2 x 21 or 2 x 29 2 x 32 I or 2 x 40 I
LE2-D09 to D35 1 x 16 or 2 x 21 2 x 20 I or 2 x 25 I 2 x 16 or 2 x 21 2 x 20 I or 2 x 25 I
LE2-D406 and LE4-D406 1 x 13 and 1 x 21 1 x 20 I and 1 x 25 I 1 x 13 and 2 x 21 1 x 20 I and 2 x 25 I
LE1-D506 to D656 and LE4-D506 and D6561 x 13 and 1 x 29 1 x 20 I and 1 x 32 I 1 x 13 and 2 x 29 1 x 20 I and 2 x 32 I
LE2-D806 and LE4-D806 1 x 13 and 1 x 36 1 x 20 I and 1 x 40 I 1 x 13 and 2 x 36 1 x 20 I and 2 x 40 I
LE4-K, LE8-K 2 x 13 and 2 x 16 4 x 20 I 2 x 13 and 2 x 16 4 x 20 I
Dimensions
References :pages 24103/2 and 24103/
3Schemes :
page 24104/3
24104_Ver2.10-EN.fm/3Schneider Electric
– Q1
– KM1 – KM2
L1 L2 L3
U V W
– KM1
O
I
– KM1
A1
A2
A
B
– KM2– KM1
– KM2
– KM2 – KM1
A1
A2
– Q1
– KM1
A1
A2
A
B
O
– KM2– KM1
– KM2 – KM1
A1
A2
A1
A2
R
A
B13
1421
22
O
l – KM1
A2
A1
– KM1
Q1– F1
B
A
Remote control
– Q1
– KM1 – KM2
L1 L2 L3
U V W
A1
A2
– KM1
– KM2
– KM2
A1
A2
– KM2
– KM1
– KM1
Q1Q1
A
B
– S1III
O
A
A1
A2
– KM1
– KM1
1817
Q1Q1
O
I
O
l
A1
A2
– KM1
– KM1
Q1– F1
B
A
– Q1
– KM1
L1 L2 L3
U WV
A1
A2
– KM1
2122
– KM2
– KM2
O
A1
A2
– KM2
– KM1
1314
l
– KM1
1314
l l
Q1– F1
A
B
TeSys enclosed starters 2
D.O.L. starters for motor control2.2 to 45 kW, with isolating device
LE4-K06, K09LE4-D09 to D806 LE4-K06, K09 LE4-D09 to D35 LE4-D406 to D656 LE4-D806
LE4-D09 to D656 with variant A04 or A05
LE8-K06, K09 LE8-K06, K09 Variante A05
LE8-D09 to LE2-D806 LE8-D09 to D35 LE2-D406 to D806
Connections A B220 V, 230 V, 240 V LE4 and LE8-K, LE4 and LE8-D09 and D12 L3 Neutral
LE4-D18 to D806, LE8-D18 to D35 and LE2-D406 to D806 L3 Neutral terminal
380 V, 400 V, 415 V, 440 V All products L3 L1Other voltages LE4 and LE8-D09 to D35 Terminal 1 Terminal 2
LE4 and LE2-D406 and D806 Direct connection
Schemes
Remote control
Remote control
References :pages 24103/2 and 24103/
3Dimensions :
page 24104/2
24105_Ver3.10-EN.fm/2 Schneider Electric
TeSys enclosed starters 2
D.O.L. starters for motor control0.25 to 7.5 kW with 3-phase thermal overload relay
Non-reversing starters
Starter LE1-M, combined with short-circuit protection components, provides type 1 or type 2 coordination, depending onthe type of devices used.
/ The standard version comprises:- 1 green Start button “I”,- 1 red Stop/Reset button “O/R”,- 1 yellow operating indicator.
/ Control may be pulsed or maintained./ An earth terminal and a neutral terminal are provided on the bottom of the enclosure.
(1) Thermal overload relay fitted as standard.(2) The contactor coil is pre-wired between 2 phases of the power circuit
Characteristics
Conforming to standards IEC 947-4-1, IEC 439-1, VDE 0660-102 and EN 60947
Degree of protection to IEC 529 IP 65
Ambient air temperature For operation: - 5 to + 40 °C
Operating positions Identical to those for k contactors
Material Self-extinguishing ABS
References
Standard power ratings Setting range Basic reference. Weightof 3-phase motors 50/60 Hz in category AC-3 of thermal overload Complete with code 220 V 380 V relay LR2-K(1) indicating power230 V 240 V 400 V 415 V circuit voltage (2)kW kW kW kW A kg
0.12 0.12 0.25 0.25 0.54…0.8 LE1-M35//05 0.600
0.18 0.18 0.37 0.37 0.8…1.2 LE1-M35//06 0.600
0.25 0.25 0.55 0.55 1.2…1.8 LE1-M35//07 0.600
0.37 0.37 1.1 0.75 1.8…2.6 LE1-M35//08 0.600
0.55 0.55 1.5 1.5 2.6…3.7 LE1-M35//10 0.600
1.1 0.75 2.2 2.2 3.7…5.5 LE1-M35//12 0.600
1.5 1.1 3 3 5.5…8 LE1-M35//14 0.600
2.2 2.2 4 4 8…11.5 LE1-M35//16 0.600
3 3 5.5 5.5 10…14 LE1-M35//21 0.600
3.7 4 7.5 7.5 12…16 LE1-M35//22 0.600
Description
Variant
Starter without Delete the last 2 digits of the starter references selected above.thermal overload relay LR2-K Example: LE1-M35//
Spare part
Description Basic reference. Complete Weightwith code indicatingpower circuit voltage (2) kg
Contactor LC1-K//A80 0.180
The codes indicated below therefore correspond to the power circuit voltage.Volts " 50/60 Hz 24 220 230 240 380 400 415 440Code B7 M7 P7 U7 Q7 V7 N7 R7Example: 380/400 V 3-phase supply, 4 kW motor: LE1-M35Q716
Characteristics, references
LE1-M35////
Dimensions :page 24105/3
Schemes : page 24105/3
24105_Ver3.10-EN.fm/3Schneider Electric
78
160
130
(5"1
/8)
108
I
O/R
1
2
3
4
5
6
13
14
A1
A2
2 4 6
L1 L2 L3
Reset/OR
T1 T2 T3
U WV
2 4 6
1/L1
3/L2
5/L3
M
– KM1 I
A
B
1413
O/R
9596
– KM1 – H1
A2
A1
– KM1I
A
B
O
9596
– KM1 – H1
A2
A1
1413
KM1
DimensionsLE1-M35 (1)
Knock-outs or blanking plugs for cable glands
(1) Can be mounted on machine panel or frame. Knock-outs for 4 x 13 P cable glands.
Enclosure type At top At bottomPG ISO PG ISO
LE1-M 2 x 13 to 2 x 21 2 x 20 I or 2 x 25 I 2 x 13 to 2 x 21 2 x 20 I or 2 x 25 I
SchemesLE1-M35 Choice of type of control built into the product
Control by Control bylatching spring returnpushbuttons pushbuttons
Connections A B220 V, 230 V, 240 V L3 Neutral380 V, 400 V, 415 V, 440 V L3 L1Other voltages Terminal 1 Terminal 2
TeSys enclosed starters 2
D.O.L. starters for motor control0.25 to 7.5 kW with 3-phase thermal overload relay
Dimensions, schemes
References : page 24105/2
or
24111_Ver3.10-EN.fm/2 Schneider Electric
(1) Avoid placing this material in contact with harsh substances (detergents, chlorinated solvents, ketones, alcohol,aromatic hydrocarbons).(2) Standard control circuit voltages
Other voltages: please consult your Regional Sales Office.(3) Example: LE1-GVME06KF7A59(4) Supplied with IP 55 sealing kit.(5) Padlockable in position “O”, by padlock with Ø 4 to 8 mm shank.
Characteristics
Conforming to standards IEC 947-4-1, IEC 439-1, VDE 0660-102 and EN 60947Degree of protection to IEC 529 IP 55Ambient air temperature For operation: - 5 to + 40 °COperating positions Identical to those for K contactorsMaterial Polycarbonate (1)
References
Standard power ratings of 3-phasemotors 50/60 Hz in category AC-3
Settingrange of
Fixedmagnetic
Basic reference.Complete with code
Weight
400 thermal tripping indicating control230 V 415 V 440 V 500 V 690 V trips current 13 Irth circuit voltage (2)kW kW kW kW kW A A kg
0.18 0.37 0.37 0.37 0.75 1…1.6 22.5 LE1-GVME06K// 1.2100.25 0.55 0.55 0.55 1.1
0.75
0.37 0.75 0.75 1.1 1.5 1.6…2.5 33.5 LE1-GVME07K// 1.2101.1
0.55 1.1 1.5 1.5 2.2 2.5…4 51 LE1-GVME08K// 1.2100.75 1.5 2.2 3
1.1 2.2 2.2 3 4 4…6.3 78 LE1-GVME10K// 1.2103
1.5 3 4 4 5.5 6…10 138 LE1-GVME14K// 1.2102.2 4 5.5 7.5
2.2 5.5 5.5 7.5 9 9…14 170 LE1-GVME16K// 1.2103 7.5 11
Variant
Description Suffix to be added tothe starter reference (3)
Weightkg
Neutral terminal A59 –
Description Reference Weightkg
Enclosure without starter, LE1-GVMEK 0.740with sealing kit fitted(references of combination motor starters forcustomer assembly, see pages 24520/2 and 24520/3)
Accessories (to be ordered separately)
Description Sold inlots of
Unitreference
Weightkg
Padlocking device (4) 1 to 3 padlocks with 1 GV2-V01 0.075for padlocking the Ø 4 to 8 mm shankGV2-ME operator(Padlocking is only possiblein the “O” (Off) position)Mushroom Spring return (4) 1 GV2-K011 0.052head Stopbutton Latching Key release (key n° 455) 1 GV2-K021 0.160Ø 40 mm, (4) IP 55 Turn to release 1 GV2-K031 0.115red 1 GV2-K04 (5) 0.120Sealing IP 55 10 GV2-E01 0.012kit IP 55 for θ < + 5 °C 10 GV2-E02 0.012
Volts " 50/60 Hz 24 42 48 110 115 220 230 240 380 400 415 440Code B7 D7 E7 F7 – M7 P7 U7 Q7 V7 N7 R7
TeSys enclosed starters 2
D.O.L. starters for motor control 0.37 to 5.5 kW with thermal magnetic circuit-breaker and contactor
Characteristics, references
LE1-GVME//K//
LE1-GVMEK
Dimensions :page 24111/3
Schemes :page 24111/3
24111_Ver3.10-EN.fm/3Schneider Electric
A1
A2
O
I – KM1
– KM1
– Q1
A
B
Externalcontrol
86
94
183
201
= =
101
A1
A2
O
I – KM1
– KM1
– Q1
A
B
Externalcontrol
86
94
183
201
= =
101
DimensionsLE1-GVMEK
SchemesLE1-GVMEK
Connections A B220 V, 230 V, 240 V L3 Neutral380 V, 400 V, 415 V, 440 V L3 L1Other voltages Terminal 1 Terminal 2
TeSys enclosed starters 2
D.O.L. starters for motor control0.37 to 5.5 kW with thermal magnetic circuit-breaker and contactor
Dimensions, schemes
References :page 24111/2
L1 L2 L3
– KM1
– Q1
24106-EN_Ver2.12.fm/2 Schneider Electric
TeSys enclosed starters 2
Star-delta starters5.5 to 132 kW, without isolating device (1)
Maximum operating rate LE 3-K: 12 starts/hour and LE3-D: 30 starts/hour.Maximum starting time: 30 seconds.LE3-D: an LAD-S2 timer imposes a delay of 40 ms ± 15 ms on the delta contactor at the moment of changeover to ensurethat the star contactor has sufficient breaking time.
(1) Protection must be provided by the addition of an overload relay, to be ordered separately. Select appropriateoverload relay for setting at 0.58 of the full load rated motor current, see pages 24514/2 and 24514/3.(2) Avoid placing this material in contact with harsh substances (detergents, chlorinated solvents, ketones, alcohol,aromatic hydrocarbons).(3) Standard control circuit voltages.
Other voltages: please consult your Regional Sales Office. (4) Selection according to dimensions and the number of operating cycles, please consult your Regional Sales Office.
Characteristics
Conforming to standards IEC 947-4-1 and IEC 439-1, VDE 0660-102, EN 60947
Degree of protection to IEC 529 IP 659: LE3-K, IP 657: LE3-D09 to D35 and IP 557: LE3-D405 to D150
Ambient air temperature For operation: - 5 to + 40 °C
Operating positions Identical to positions for contactors
Material Polycarbonate (2): LE3-K and LE3-D09 to D35. Sheet steel: LE3-D405 to D150
References
Standard power ratings Basic reference. Weightof squirrel cage motors Complete with codeMains voltage - delta connection indicating control220 V 380 V 415 V 440 V circuit voltage
400 V (3)kW kW kW kW kg
3 5.5 5.5 5.5 LE3-K065 1.460
4 7.5 7.5 7.5 LE3-K095 1.460
or LE3-D09 (4) 3.650
5.5 11 11 11 LE3-D12 3.650
11 18.5 22 22 LE3-D18 3.750
15 30 30 30 LE3-D35 5.160
18.5 37 37 37 LE3-D405 8.160
30 55 59 59 LE3-D505 8.150
37 75 75 75 LE3-D805 14.000
63 110 110 110 LE3-D115 24.500
75 132 132 147 LE3-D150 24.500
Volts 50/60 Hz 24 42 48 110 115 220 230 240 380 400 415 440LE3-K B7 D7 E7 F7 – M7 P7 U7 – – – –LE3-D B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7
Characteristics, references
LE3-D12
Dimensions :page 24107/2
Schemes :page 24107/3
24106-EN_Ver2.12.fm/3Schneider Electric
TeSys enclosed starters 2
Star-delta starters5.5 to 132 kW, without isolating device
The standard version comprises:
(1) Example: LE3-D09F7A04
Description
- LE3-K and LE3-D09 to D35: 1 green Start button “I” 1 red Stop/Reset button “O”
- LE3-D405 to D150: no pushbuttons on cover.
Variants (pre-assembled)
Description Application Suffix to be addedto the starter reference (1)
No pushbuttons on cover LE3-D09…D35 A04
1 green Start button “I” LE3-D405…D150 A061 red Stop/Reset button “O”
1 blue Reset button “R” LE3-D09…D805 A05
1 neutral terminal LE3-K065 and K095 A59Fitted as standard on starters LE3-D09…D805LE3-D115 and D150
Mechanical interlock LE3-D405 to D150 A64Fitted as standard on starters LE3-K and LE3-D09 to D35
Other versions Possible combinations of 2 variants.Please consult your Regional Sales Office.
References
LE3-D12A04
LE3-D12A05
Schemes :page 24107/3
24107_Ver2.20-EN.fm/2 Schneider Electric
c1
348
330
==
=
186
=
84
175
150
146
120
165
19
287
c1 =
367
= 225
195
==
b (1
)
c1
c1 + 15,5
== a - 75
a - 50
a
a + 57,5
b -
50
b +
57,
5
b -
75=
=
TeSys enclosed starters 2
Star-delta starters5.5 to 132 kW, without isolating device
LE3-D805 to D150
Knock-outs or blanking plugs for cable glands
LE3-K065, K095 LE3-D09 to D35
c1Standard version 175.5Version A04 167Version A05 175.5
LE3-D405 and D505
c1Standard version 190Version A05 194Version A06 194
LE3- a bD805 400 400D1155 500 600D1505 500 600
c1LE3-D805 LE3-D115, D150
Standard version 202 252Version A05 218 –Version A06 218 268
(1) + 14 mm with blanking plugs.
Type of enclosure At top At bottomPG ISO PG ISO
LE3-D09 to D35 2 x 13 or 2 x 16 or 2 x 20 I or 2 x 25 I or 2 x 13 or 2 x 16 or 2 x 20 I or 2 x 25 I or2 x 21 or 2 x 29 2 x 32 I or 2 x 40 I 2 x 21 or 2 x 29 2 x 32 I or 2 x 40 I
LE3-D405 1 x 29 1 x 32 I 1 x 29, 2 x 13 and 2 x 21 1 x 32 I, 2 x 20 I and 2 x 25 I
LE3-D505 1 x 36 1 x 40 I 1 x 36, 2 x 13 and 2 x 29 1 x 40 I, 2 x 20 I and 2 x 32 I
LE3-D805 1 x 36 1 x 40 I 2 x 13 and 3 x 36 2 x 20 I and 3 x 40 I
LE3-K 2 x 13 and 2 x 16 4 x 20 I 2 x 13 and 2 x 16 4 x 20 I
Dimensions
References :pages 24106/2 and
24106/3
24107_Ver2.20-EN.fm/3Schneider Electric
A
O
– KM3 – KM2– KM1T
T
– KM1
I
Y
L
A1
A2
A1
A2
A1
A2
A1
A2
– KM1– KM3
– KM2
B
– KM2 – KM3 – KM1
L1 L2 L3
U1
V1
W1
U2
V2
W2
U1
V1
W1
U2
V2
W2
Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end).
U1
V1
W1
U2
V2
W2
Ð KM2 Ð KM3 Ð KM1
U1
V1
W1
U2
V2
W2
L1 L2 L3
Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end).
1718
l
A1
A2
– KM1
– KM3
– KM2
– KM1
– KM2
A1
A2
– KA1
A1
A2
– KM2
– KM1
– F2
– KM2
– KM1
A1
A2
– KM3
– KA1
YL
A
B
U1
V1
W1
U2
V2
W2
Ð KM2 Ð KM3 Ð KM1
U1
V1
W1
U2
V2
W2
L1 L2 L3
Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end).
A1
A2
– KM1
– KM3
– KM2
– KM1
– KM2
A1
A2
– KM3
– KM1
A1
A2
– KM2
– KM2
B
A
O
I
Y
L
A1
A2
– KM1
1718
– KM3
– KM2
– KM1
– KM2
A1
A2
– KM3
– KM1
A1
A2
– KM2
– KM2
B
A
I
Y
L
Note : in accordance with current installation regulations, short-circuit protection must be provided by fuses or a circuit-breaker.
LE3-K065 and K095 LE3-K065 and K095
LE3-D09 to D805 LE3-D09 to D35 LE3-D405 to D805
LE3-D115 and D150 LE3-D115 and D150
Connections A B220 V, 230 V, 240 V LD09 and D12 L3 Neutral
LE3-D18 to D150 L3 Neutral terminal380 V, 400 V, 415 V, 440 V All products L3 L1Other voltages LE3-D09 to D35 Terminal 1 Terminal 2
LE3-K and LE3-D405 to D150 Direct connection
TeSys enclosed starters 2
Start-delta starters5.5 to 132 kW, without isolating device
Schemes
Remotecontrol
Remotecontrol
References : pages 24106/2 and
24106/3Dimensions :
page 24107/2
24108_Ver2.10-EN.fm/2 Schneider Electric
TeSys enclosed starters 2
Star-delta starters (1)
7.5 to 75 kW with isolating device
Maximum operating rate: 30 starts/hour. Maximum starting time: 30 seconds.An LAD-S2 timer imposes a delay of 40 ms ± 15 ms on the delta contactor at the moment of changeover to ensure thatthe star contactor has sufficient breaking time.
(1) Protection must be provided by the addition of an overload relay, to be ordered separately. Select appropriate overloadrelay for setting at 0.58 of the full load rated motor current, see pages 24514/2 and 24514/3.(2) Avoid placing this material in contact with harsh substances (detergents, chlorinated solvents, ketones, alcohol,aromatic hydrocarbons).(3) Standard control circuit voltages.
Other voltages: please consult your Regional Sales Office.
Characteristics
Conforming to standards IEC 947-4-1 and IEC 439-1, VDE 0660-102, EN 60947
Degree of protection to IEC 529 IP 657: LE6-D09 to D18 and IP 557: LE3-D326 to D806
Ambient air temperature For operation: - 5 to + 40 °C
Operating positions Identical to positions for contactors
Material Polycarbonate (2): LE6-D. Sheet steel: LE3-D
References
Standard power ratings Fuses to be fitted Basic reference. Weightof squirrel cage motors by the customer Complete with codeMains voltage - Delta connection Size Type indicating control220 V 380 V 415 V 440 V aM circuit voltage Standard
400 V (3) voltageskW kW kW kW A kg
4 7.5 7.5 7.5 10 x 38 20 LE6-D09// F7 P7 V7 3.900
5.5 11 11 11 10 x 38 25 LE6-D12// F7 P7 V7 3.900
11 18.5 22 22 14 x 51 40 LE6-D18// F7 P7 V7 4.850
15 30 30 30 22 x 58 63 LE6-D326// F7 P7 V7 7.650
18.5 37 37 37 22 x 58 80 LE3-D406// F7 P7 V7 16.900
30 55 59 59 22 x 58 125 LE3-D506// F7 P7 V7 17.000
37 75 75 75 0 160 LE3-D806// F7 P7 V7 27.500
Volts 24 42 48 110 115 220 230 240 380 400 415 44050/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7
Characteristics, references
LE6-D12//
Dimensions :page 24109/2
Schemes :page 24109/3
:
24108_Ver2.10-EN.fm/3Schneider Electric
TeSys enclosed starters 2
Star-delta starters7.5 to 75 kW with isolating device
The standard version comprises:
(1) Example: LE6-D09F7A04.
Description
- LE6-D09 to D18: 1 green Start button “I”1 red Stop/Reset button “O”
- LE3-D326 to D806 no pushbuttons on cover
Protection Power circuit Control circuitLE6-D09 and D12 1 3-pole isolating device + 1 additional pole LA8-D254LE6-D18 to LE3-D806 1 3-pole isolating device + 1 circuit breaker GB2-CB08
Variants (pre-assembled)
Description Application Suffix to be added tothe starter reference (1)
No pushbuttons on cover LE6-D09…D18 A04
1 green Start button “I” LE3-D326 to D806 A061 red Stop/Reset button “O”
1 blue Reset button “R” LE6-D09…LE3-D806 A05
1 neutral terminal LE6-D09…D806 A59
Mechanical interlock LE3-D326…D806 A64Fitted as standard on starters LE6-D09 to D18
References
LE6-D12//A04
LE6-D12//A05
Schemes :page 24109/3
24109_Ver2.10-EN.fm/2 Schneider Electric
190
367
225
==
=
287
=
31
195c1
348
330
==
=
186 31
=
b (1
)
c1
== a-75
a-50
a
a+57,5
b-50
b+57
,5
b-75
==
4xM8x25
31
TeSys enclosed starters 2
Star-delta starters7.5 to 75 kW, with isolating device
LE3-D406 to D806
Knock-outs or blanking plugs for cable glands
LE6-D09 to D18 LE3-D326
c1Standard version 175.5Version A04 167Version A05 175.5
LE3- a b c1D406, D506 400 500 218D806 500 700 269
(1) + 14 mm with blanking plugs.
Type of enclosure At top At bottomPG ISO PG ISO
LE6-D09 to D18 2 x 13 or 2 x 16 or 2 x 20 I or 2 x 25 I or 2 x 13 or 2 x 16 or 2 x 20 I or 2 x 25 I or2 x 21 or 2 x 29 2 x 32 I or 2 x 40 I 2 x 21 or 2 x 29 2 x 32 I or 2 x 40 I
LE3-D326 1 x 21 1 x 32 I 2 x 13, 2 x 16 & 1 x 21 2 x 20 I, 2 x 25 I &1 x 32 I
LE3-D406 1 x 29 1 x 32 I 2 x 13, 2 x 21 & 1 x 29 2 x 20 I, 2 x 25 I & 1 x 32 I
LE3-D506 1 x 36 1 x 40 I 2 x 13, 2 x 29 & 1 x 36 1 x 40 I, 2 x 20 I & 2 x 32 I
LE3-D806 1 x 36 1 x 40 I 2 x 13 & 3 x 36 2 x 20 I and 3 x 40 I
Dimensions
References :pages 24108/2 and 24108/3
Schemes :page 24109/3
24109_Ver2.10-EN.fm/3Schneider Electric
A1
A2
– KM1
– KM3
– KM2
– KM1
l
– KM2
A1
A2
– KM3
– KM1
A1
A2
– KM2
– KM2
B
O
A
Q1Q1
A1
A2
– KM1
1314
– KM3
– KM2
– KM1
l
– KM2
A1
A2
– KM3
– KM1
A1
A2
– KM2
– KM2
B
A
Q1– F1
2122
– S1
– KM2
12
34
56
– KM3
12
34
56
– KM1
12
34
56
U1
V1
W1
U2
V2
W2
1 3 5
2 4 6
– Q1
1/L1
2
3/L2
4
5/L3
6 U1
V1
W1
U2
V2
W2
2 4 6
U1
V1
W1
U2
V2
W2
2 4 6
– KM2
12
34
56
– KM3
12
34
56
– KM1
12
34
56
U1
V1
W1
U2
V2
W2
1 3 5
2 4 6
– Q1
1/L1
2
3/L2
4
5/L3
6
TeSys enclosed starters 2
Star-delta starters7.5 to 75 kW, with isolating device
Recommended cabling forreversal ofmotor rotation(standard motor,viewed from shaftend).
Recommended cabling forreversal ofmotor rotation(standard motor,viewed from shaftend).
LE6-D09 to D18 LE6-D09 to D18
LE3-D326 to D806 LE3-D326 to D806
Connections A B220 V, 230 V, 240 V LE6-D09 and D12 L3 Neutral
LE6-D18 to LE3-D806 L3 Neutral terminal380 V, 400 V, 415 V, 440 V All products L3 L1Other voltages LE6-D09 to D18 Terminal 1 Terminal 2
LE3-D326 to D806 Direct connection
Schemes
Remotecontrol
References :pages 24108/2 and 24108/3
Dimensions :page 24109/2
24120-EN_Ver1.2.fm/2 Schneider Electric
References TeSys enclosed starters 2
Replacement parts for starterswithout isolating device
(1) Do not forget to order adaptation kit LAD-9091 or LAD-91810, depending on size.(2) Do not forget to order adaptation kit LAD-9092.(3) Sold in lots of 10.(4) LE1, LE2, LE3, LE4, LE6 or LE8.
Heads for Start and Stop/Reset pushbuttonsDescription For use on Unit
referenceWeight
kg
Flush, green “I” (1) LE1-D09...D35 ZB5-AA331 0.018
Projecting, red “O” (1) LE1-D09...D35 ZB5-AL432 0.019
Adaptation kit for head ZB5-AL432
LE1-D09 and D12 LAD-9091 0.002
LE1-D18...D35 LAD-91810 0.003
Heads for Reset pushbuttons
Flush, blue “R” (2) LE1-D09...D35 ZB5-AA0 0.022
+ ZBA-639 (3) 0.001
Adaptation kit for head ZB5-AA0 + ZBA-639
LE1-D09 and D12 LAD-9092 0.002
LE1 or LE2-D18...D35 LAD-91810 0.003
LE3, LE6, LE4 or LE8-D09...D35
LAD-9T4 0.004
Heads for selector switches
3 position stay put LE1-D09...D35 ZB5-AD3 0.024
2 position stay put LE1-D09...D35 ZB5-AD2 0.024
3 position spring return to centre
LE1-D09...D35 ZB5-AD5 0.024
Contact blocks
1 N/O spring return
LE1-D09...D35 ZEN-L1111 0.010
1 N/C spring return
LE1-D09...D35 ZEN-L1121 0.010
Mounting for contact block LE1-D09 and D12 LAD-90909 0.008
LEp-D18...D35 (4) LAD-91809 0.014
ZB5-AA331
5001
18_
1
ZB5-AL432
500
120_
1
LAD-9091
500
117_
1
ZB5-ADp
5001
19_1
ZEN-L1111
500
121_
1
LAD-91809
5001
22_1
24120-EN_Ver1.2.fm/3Schneider Electric
References TeSys enclosed starters 2
Replacement parts for starterswithout isolating device
Empty enclosures for D.O.L. starters without isolating deviceIntended usage Head(s) mounted
on coverReference Weight
kg
LE1-D09, D12 Without DE1-DS1A04 0.300
1 flush blue head “R” DE1-DS1A05 0.300
1 flush green head “I” DE1-DS1 0.3001 projecting red head “O”
1 flush blue head “R”1 switch
DE1-DS1A13 0.300
LE1-D18...D35 Without DE1-DS2A04 0.500
1 flush blue head “R” DE1-DS2A05 0.500
1 flush green head “I” DE1-DS2 0.500
1 projecting red head “O”
1 flush blue head “R”1 switch
DE1-DS2A13 0.500
DE1-DS1A04
8101
75
DE1-DS1A05
810
176
DE1-DS1
810
173
DE1-DS1A13
8101
78
25017_Ver4.20-EN.fm/2 Schneider Electric
Maximum operating rate : 12 starts/hour. Maximum starting time : 20 seconds
(1) Protection must be provided by the addition of a thermal overload relay, to be ordered separately. Select appropriateoverload relay for setting at 0.58 the full load rated motor current, see pages 27074/2 to 27074/3.(2) Standard control circuit voltages (variable delivery time, please consult your Regional Sales Office).
For other voltages, see replacement coil pages 25014/2 to 25014/9.(3) LC1-F185 and F225 : contactors fitted with LX9-F coils; LC1-F265…F400 : contactors fitted with LX1-F coil.(4) Example : LE3-F185M7A06
Standard power ratings Basic reference. Weightof squirrel cage motors (3) Complete with codeMains voltage - delta connection indicating control Usual220 V 380 V 415 V 440 V circuit voltage (2)(3) voltageskW kW kW kW kg
90 160 160 185 LE3-F185// F7 P7 V7 31.400
100 200 200 220 LE3-F225// F7 P7 V7 33.000
110 220 220 250 LE3-F265// F7 P7 V7 50.800
160 280 280 315 LE3-F330// F7 P7 V7 80.000
185 315 355 375 LE3-F400// F7 P7 V7 82.000
Specifications
Enclosure LE3-F185 to F400 Metal enclosure, IP 559
No pushbuttons on cover LE3-F185 to F400 –
Connections LE3-F185 to F400 Pre-wired power and controlcircuit connections
Variants (mounted by Telemecanique)
Description For Suffix to be addeduse on to starter reference (4)
1 green Start button “I” LE3-F185 to F400 A061 red Stop/Reset button “O”
Volts 48 110 220/230 230 240 380/400 400 41550/60 Hz E7 F7 M7 P7 U7 Q7 V7 N7
Other versions Possible combinations of 2 variants.Please consult your Regional Sales Office.
References Enclosed starters 2
Star-delta starters (1)
90 to 375 kW, without isolator
LE3-F
Dimensions :page 25017/3
Schemes :page 25017/3
25017_Ver4.20-EN.fm/3Schneider Electric
b (1
)
c
c1
== a-75
a-50
a
a+57,5
b-50
b+57
,5
b-75
==
4xM8x25
– KM2
12
34
56
– KM3
12
34
56
– KM1
12
34
56
U1
V1
W1
U2
V2
W2
1 3 5
2 4 6
L1 L2 L3
U1
V1
W1
U2
V2
W2
2 4 6
Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end).
A1
A2
– KM1
1314
2122
6261
– KM3
5556
– KM2
5354
– KM1
9596
– F1
– F1
KM3:5
O
l
6768
– KM2
A1
A2
– KA1
A1
A2
– KM2
5354
– KM2
(13)
(14)
– F2
KM3:1
6261
– KM1
1314
A1
A2
– KM3
– KA1
DimensionsLE3-F///
SchemesLE3-F///
Note : in accordance with current installation regulations, short-circuit protection must be provided by fuses or a circuit breaker.
LE3- a b (4) c c1 Knock-outs or blanking plugs for cable glandsF185, F225 600 700 303 319F265 700 900 303 319 Enclosure At AtF330, F400 800 1000 403 419 type top bottom
LE3-F185, F225 2 x 48 P 2 x 13 P and 4 x 48 PLE3-F265 to 400 – –
.(1) + 14 mm with blanking plugs
Remotecontrol
Enclosed starters 2
Star-delta starters 90 to 375 kW, without isolator
Dimensions, schemes
References :page 25017/2
24034-EN_Ver3.1.fm/2 Schneider Electric
Opera- Minimum Fuses to For use with Basic reference. Weighttional c.s.a. be fitted relay LR2-D Complete with codecurrent of separately or kit LA9-D indicating controlup to phase (to be ordered circuit Usual
conductors aM gG separately) voltage (2) voltagesA mm2 A A kg
16 2.5 – 16 LA9-D1275 (4) LE1-D123pp M7 Q7 0.920
17.5 1.5 20 – LR2-D1321 (3) LE1-D123pp M7 Q7 0.920
24 2.5 25 – LR2-D1322 (3) LE1-D255pp M7 Q7 1.015
32 6 – 32 LA9-D0975 (4) LE1-D255pp M7 Q7 1.015
50 10 – 50 – LE1-D405ppA04 (5) M7 Q7 4.820
57 10 63 – LR2-D3359 (3) LE1-D405pp M7 Q7 4.820
63 16 – 63 – LE1-D655ppA04 (5) M7 Q7 4.850
76 16 80 – LR2-D3363 (3) LE1-D655pp M7 Q7 4.850
90 25 100 – LR2-D3365 (3) LE1-D805pp M7 Q7 5.140
100 35 – 100 – LE1-D805ppA04 (5) M7 Q7 5.140
Specifications
Enclosure LE1-D12 Double insulated, degree of protection IP 659
LE1-D25 Double insulated, degree of protection IP 557
LE1-D40…D80 Metal, degree of protection IP 559
Control (2 pushbuttons mounted on enclosure cover)
LE1-D12…D80 1 green Start button “I” 1 red Stop/Reset button “O”
No pushbuttons on cover LE1-DpppppA04
Connections LE1-D12…D80 Pre-wired control circuit connections
(1) 3-phase 220/230 V or 380/400 V or 415 V 50/60 Hz. 3-core or 3 + N (unprotected neutral) insulated PVC cable,fixed to walls, in cable racks or ducting, laid singly, ambient temperature 35 °C, conforming to NF C 15-100.(2) Control circuit voltage 220/230 V 50/60 Hz (code M7) or 380/400 V (code Q7).(3) Order the required LR2-D thermal overload relay separately. For use on balanced circuits only.(4) As protection is provided by type gG fuses only, the Stop function normally provided by the thermal overload relay(where aM type fuses are used) can be obtained by means of kit LA9-Dpp75.(5) Equipment supplied without pushbuttons; external Start-Stop station required.
Enclosed starters 2
D.O.L. starters and equipment, without isolatorEquipment for control in utilisation category AC-1, (1), (3)
References
LE1-D405
LE1-D123
a
Dimensions :page 24044/2
Schemespage 24044/3
24034-EN_Ver3.1.fm/3Schneider Electric
Enclosed starters 2
D.O.L. starters and equipment, without isolatorEquipment for control in utilisation category AC-1, (1), (2)
(1) 3-phase 220/230 V or 380/400 V 50/60 Hz. 3-core or 3 + N (unprotected neutral) insulated PVC cable, fixed towalls, in cable racks or ducting, laid singly, ambient temperature 35 °C, conforming to NF C 15-100.(2) Order the required LR2-D thermal overload relay separately. For use on balanced circuits only.(3) Example: LE1-D123M7A04.
Variants (pre-mounted)
Description For Suffix to be addeduse on to the reference (3)
No pushbuttons on cover LE1-D12 & D25 A04
1 blue Reset button “R” LE1-D12…D80 A05
1 green Start button “I” and 1 red Stop LE1-D12 & D25 A07button "O” with 1 N/C contact(for distribution circuitswithout thermal overload relay)
1 2-position selector switch "O-I” LE1-D12 A13("O”: Stop ; "I”: Manual Start)1 blue Reset button "R”
Knock-outs for 4 x 16 mm plastic cable glands LE1-D12 A20(instead of 4 x 13 plastic glands)
1 neutral terminal (3-phase + N circuits) LE1-D12…D80 A59
Accessories (mounted by the customer)
Description For Reference Weightuse on kg
Start button latching device LE1-D25…D65 LA9-D09907 0.060for stay put operation(Start-Stop)
Kits to provide stop function without LE1-D12 LA9-D1275 0.040thermal overload relay fitted
LE1-D25 LA9-D0975 0.020
Miniature control LE1-D12 LA9-D931 0.040circuit fuse holdersize 5 x 20A 4/250 VFuse supplied LE1-D25 LA9-D941 0.025
Pilot light with neon bulb, 110 V LE1-D12 & D25 LA9-D924 0.020red lens and locking ring
220 V LE1-D12 & D25 LA9-D925 0.020
380, 415 V LE1-D12 & D25 LA9-D926 0.020
1 front-mounting block LE1-D12… D80 LA1-DNpp 0.030of 2 auxiliary contacts Please consult your Regional Sales Office
Other versions Possible combinations of 2 variants.Please consult your Regional Sales Office.
References
Schemes:page 24044/3
24044-EN_Ver2.11.fm/2 Schneider Electric
Enclosed starters 2
D.O.L. starters and equipment, without isolator
Knock-outs or blanking plugs for cable glands
LE1-D123 LE1-D255 LE1-D405, D655
(1) 150 for LE1-DpppppA04 (without pushbuttons).
LE1-D805
Type of enclosure At top At bottomLE1-D123 2 x 13 P 2 x 13 P
LE1-D255 1 x 13 P and 1 x 16 P 2 x 16 P
LE1-D and LE1-D655 1 x 13 P and 1 x 29 P 1 x 13 P and 2 x 29 P
LE1-D805 1 x 13 P and 1 x 36 P 1 x 13 P and 2 x 36 P
120
140
166
150
==
=
88
=18
5135
142
=
101
=
165
==
150
161 (1)
312
=
181
= 105
195
==
165
c1
307
=
257
= 165
165
==
Dimensions
References : pages 24034/2 and
24034/3Schemes :
page 24044/3
24044-EN_Ver2.11.fm/3Schneider Electric
Enclosed starters 2
D.O.L. starters and equipment, without isolator
D.O.L. starters and equipment for control in category AC-1 LE1-D123 to D805 LE1-D123 LE1-D255 to D805 LE1-DpppppA04, LE1-DpppppA05LE1-DpppppA04
2 4 6
1/L1
3/L2
– KM1
1 3 5
2 4 6
U V W5/
L3
N
KM1/1
KM1/5
A1
A2
– KM1
1413
– KM1
1413
O
9596
I
O
l
N
KM1/1
KM1/5
A1
A2
– KM1
1413
– KM1
1817
9596
1314
2122
9596
KM1/5
O
l
1413
– KM1
N
KM1/1
A1
A2
– KM1
Schemes
References : pages 24034/2 and
24034/3Dimensions :
page 24044/2
Remotecontrol
24033-EN_Ver3.1.fm/2 Schneider Electric
Enclosed starters 2
D.O.L. starters and equipment, with off-load isolatorEquipment for control in utilisation category AC-1, (1), (3)
(1) 3-phase 220/230 V or 380/400 V 50/60 Hz. 3-core or 3 + N (unprotected neutral) insulated PVC cable, fixed to walls,ceilings, in cable racks or ducting, laid singly, ambient temperature 35 °C, conforming to NF C 15-100.(2) Control circuit voltage 220/230 V 50/60 Hz (code M7) or 380/400 V (code Q7).(3) Order the required LR2-D thermal overload relay separately. For use on balanced circuits only.(4) As protection is provided by type gG fuses only, the Stop function normally provided by the thermal overload relay(where aM type fuses are used) can be obtained by means of kit LA9-D0975.(5) Equipment supplied without pushbuttons; external Start-Stop station required.
Operational Minimum Fuses to be For use with Basic reference . Weightcurrent c.s.a. fitted by customer relay LR2-D Complete with codeup to of or kit LA9-D indicating control
phase Size Type (to be ordered circuit Usualconductors aM gG separately) voltage (2) voltages
A mm2 A A kg
16 2.5 10 x 38 – 16 LA9-D0975 (4) LE4-D126pp M7 Q7 1.960
17.5 1.5 10 x 38 20 – LR2-D1321 (3) LE4-D126pp M7 Q7 1.960
20 2.5 10 x 38 – 20 LA9-D0975 (4) LE4-D256pp M7 Q7 2.200
22 2.5 10 x 38 25 – LR2-D1322 (3) LE4-D256pp M7 Q7 2.200
40 10 14 x 51 – 40 – LE4-D406ppA04 (5) M7 Q7 5.770
45 10 14 x 51 50 – LR2-D3357 (3) LE4-D406pp M7 Q7 5.770
63 16 22 x 58 – 63 – LE4-D656ppA04 (5) M7 Q7 6.670
76 16 22 x 58 80 – LR2-D3363 (3) LE4-D656pp M7 Q7 6.670
90 25 22 x 58 100 – LR2-D3365 (3) LE4-D806pp (5) M7 Q7 7.100
100 35 22 x 58 – 100 – LE4-D806pp (5) M7 Q7 7.100
Specifications
Enclosure LE4-D12 and D25 Double insulated, degree of protection IP 557
LE4-D40…D80 Metal, degree of protection IP 559
Control (2 pushbuttons LE4-D12…D65 1 green Start button “I” mounted on enclosure cover) 1 red Stop/Reset button “O”
No pushbuttons on cover LE4-Dppppp A04 –LE4-D80
Isolator with LE4-D12 and D25 1 3-pole isolator + 1 additional pole LA8-D254external operator
LE4-D40…D80 1 3-pole isolator + 1 circuit breaker GB2-CB08
Connections LE4-D12…D80 Pre-wired power and control circuit connections
References
LE4-D126
LE4-D406
a
Dimensions :page 24045/2
Schemes :page 24045/3
24033-EN_Ver3.1.fm/3Schneider Electric
Enclosed starters 2
D.O.L. starters and equipment, with off-load isolatorEquipment for control in utilisation category AC-1, (1), (3)
(1) 3-phase 220/230 V or 380/400 V 50/60 Hz. 3-core or 3 + N (unprotected neutral) insulated PVC cable, fixed to walls,in cable racks or ducting, laid singly, ambient temperature 35 °C, conforming to NF C 15-100.(2) Order the required LR2-D thermal overload relay separately. For use on balanced circuits only.(3) Example : LE4-D126M7A04.
Variants (pre-mounted)
Description For Suffix to be use on added to reference (3)
No pushbuttons on cover LE4-D12 & D25 A04
1 blue Reset button “R” LE4-D12…D80 A05
1 green Start button “I” and 1 red Stop LE4-D12 & D25 A07button “O” with 1 N/C contact (for distribution circuitswithout thermal overload relay)
1 neutral terminal (for 3-phase + N circuits) LE4-D12…D80 A59
Accessories (mounted by the customer)
Description For Reference Weightuse on kg
Start button latching device LE4-D12…D65 LA9-D09907 0.060for stay put operation(Start-Stop)
Kit to provide Stop function without LE4-D12 & D25 LA9-D0975 0.020thermal overload relay fitted
Miniature control LE4-D12 & D25 LA9-D941 0.025circuit fuse holdersize 5 x 20, 4 A/250 VFuse supplied
Pilot light with neon bulb, 110 V LE4-D12 & D25 LA9-D924 0.020red lens and locking ring
220 V LE4-D12 & D25 LA9-D925 0.020
380, 415 V LE4-D12 & D25 LA9-D926 0.020
1 front-mounting block LE4-D12…D80 LA1-DNpp 0.030of 2 auxiliary contactsPlease consult your Regional Sales Office
Other versions Possible combinations of 2 variants.Please consult your Regional Sales Office.
References
Schemes :page 24045/3
24045-EN_Ver2.11.fm/2 Schneider Electric
(1) + 14 mm with blanking plugs.
LE4-D126, D256
LE4- c c1D126 132 139D256 144 151
LE4-D406, D656
(1) c1 = c for LE4-Dppppp A04 (without pushbuttons).
LE4-D806
Knock-outs or blanking plugs for cable glandsType of enclosure At At
top bottomLE4-D126 2 x 13 P 2 x 13P
LE4-D256 1 x 13 P and 2 x 16 P1 x 16 P
LE4-D406 1 x 13 P and 1 x 13 P and 2 x 21 P1 x 21 P
LE4-D656 1 x 13 P and 1 x 13 P and 2 x 29 P1 x 29 P
LE4-D806 1 x 13 P and 1 x 13 P and 2 x 36 P1 x 36 P
c
c1
280
260
==
=
122
=
31
b
c
c1 (1)
=
a
=
31
G
H=
=
b (1
)
c
c1
== a-75
a-50
a
a+57,5
b-50
b+57
,5
b-75
==
4xM8x25
31
References :pages 24033/2 and 24033/
3Schemes :
page 24045/3
Dimensions Enclosed starters 2
D.O.L. starters and equipment, with off-load isolator
24045-EN_Ver2.11.fm/3Schneider Electric
D.O.L. starters and equipment for control in category AC-1 LE4-D126 and D806 LE4-D126 and D256 LE4-D406 and D656 LE4-D806LE4-DpppppA04 LE4-DpppppA04, DpppppA05
2 4 6
– Q1
2 4
1 3
– KM1
1/L1
3/L2
5/L3
U WV
1 3 5
2 4 66
5
O
l
N
Q1/6
Q1/2
A1
A2
– KM1
1413
– KM1
1817
9596
90
Q1Q1 13
14
O
l
N
Q1/6
Q1/2
A1
A2
– KM1
1413
– KM1
1817
9596
Q1
1314
– F1
1314
2122
9596
O
l
1413
– KM1
N
Q1/1
A2
A1
– KM1
Q1/2
Q1
1413
– F1
Schemes Enclosed starters 2
D.O.L. starters and equipment, with off-load isolator
References :pages 24033/2 and 24033/
3Dimensions :
page 24045/3
Remotecontrol
21174_Ver2.10-EN.fm/2 Schneider Electric
Enclosed starters 2
integral 18, 32 and 63 contactor breakers and reversing contactor breakersfor customer assembly
(1) Enclosures supplied with drillings and removable blanking plugs for addition of cable glands (to be orderedseparately): for number and diameter, see page 21175/2.
Empty metal enclosures
Type of For use Reference Weightenclosure on integral kg
Degree of protection IP 54 LD1, LD3 or LD5-LB DE1-LT615 2.110with drillings for doorinterlock mechanism(interlock not supplied) ,for customer assembly (1) LD1 or LD4-LC DE1-LT215 2.110
LD5-LC DE1-LT225 2.710
LD1 or LD4-LD DE1-LT315 3.510
Door interlock mechanisms (IP54)
Type For use Colour Reference Weighton enclosure of knob kg
Non-adjustable DE1-LT615 Red LA9-LB320 0.200
Black LA9-LB321 0.200
DE1-LT215 Red LA9-LC320 0.200
Black LA9-LC321 0.200
DE1-LT225 Red LA9-LC520 0.200
Black LA9-LC521 0.200
DE1-LT315 Red LA9-LC320 0.200(LD1)
Black LA9-LC321 0.200
DE1-LT315 Red LA9-LC520 0.200(LD4)
Black LA9-LC521 0.200
Spare part
Description For use Reference Weighton kg
Kit for lockable For converting a black, LA9-LC393 0.100knob on non-lockable control knobLD1-LC to a lockable knob
References
DE1-LT215
DE1-LT615
Dimensions :pages 21175/2 and
21175/3
21174_Ver2.10-EN.fm/3Schneider Electric
Enclosed starters 2
integral 18, 32 and 63 contactor breakers and reversing contactor breakersfor customer assembly
Empty insulated enclosures
Type of For use Reference Weightenclosure on integral kg
Degree of protection IP 30 LD1-LB DE1-LB001 0.750with rectangular cut-outto suit fascia of thecontactor breaker
Degree of protection IP 54 LD1-LB DE1-LB005 0.750with drillings for door interlockmechanism (interlock not supplied),for customer assembly
Degree of protection IP 30 LD1 or LD4-LC/30 DE1-LC001 1.370with rectangular cut-outto suit fascia of thecontactor breaker
References
DE1-LC001
Dimensions :pages 21175/2 and
21175/3
21175_Ver2.11-EN.fm/2 Schneider Electric
145
201
183
= =
109
145
201
= =109
104,
75
183
8,5
c69
b
DE1-LT315
DE1-LT225
a
=G=
H=
=
15069
312
105= =
=
195
=
181
280
114
123
183
=26
0=122
= =
Enclosed starters 2
integral 18, 32 and 63 contactor breakers and reversing contactor breakersEnclosures
Metal enclosures, IP54 degree of protection
Number of blanked-off cable entries for addition of cable glands
Insulated enclosures
DE1-LC001
DE1-LT215, LT615 DE1-LT225, LT315
At cable Ø For cable gland DE1- a b c G H DE1- top bottom min max N° Type LT225 257 307 165 165 165LT215 2 1 10 12 13 13M LT315 287 367 190 192 225
1 2 14 18 21 21MLT225 1 2 10 12 13 13M
1 2 14 18 21 21MLT315 1 2 10 12 13 13M
1 2 24 30 36 36MLT615 2 1 10 12 13 13M
1 2 14 18 21 21M
DE1-LB001 DE1-LB005
Dimensions
References : pages 21174/2 and
21174/3
21175_Ver2.11-EN.fm/3Schneider Electric
= =28
105
90
==
243
6359 59
105
105
181
45
275
(1)
174 (LD5)54
65
105
105
172 (LD4)
19= =
80
66
==
38= =
80
85
52 33
85= =
80
132
99 33
8080
135
182
54
65
(1)
= =
==
54
54148,
5
13454
65
(1)
Enclosed starters 2
integral 18, 32 and 63 contactor breakers and reversing contactor breakers
integral 18Non-adjustable door interlock mechanisms LA9-LB32/
integral 32Non-adjustable door interlock mechanisms LA9-LC32/ and LA9-LC52/
integral 63Non-adjustable door interlock mechanisms LA9-LC33/ and LA9-LC53/For mounting on LD4-LD/30 and LD5-LD/30
For mounting on LD1-LB030 + LB/-LB03P//LD5-LB130 + LB/-LB03P// Door drillings
(1) Thickness: 5 mm max.
For mounting on LD4-LC/30 and LC/40, LD5-LC/30
LD4-LC/30 LD4-LC/40 LD5-LC/30 Door drillings
(1) Thickness: 5 mm max.
LD4-LD/30 LD5-LD/30 Door drillings
(1) Thickness: 5 mm max.
Mounting of accessories
References : pages 21174/2 and
21174/3
= =
==
54
54
= =
==
54
54
21015_Ver3.11-EN.fm/2 Schneider Electric
(2) The closing time “C” is measured from the moment the coil supply is switched on to initial contact of the main poles.The opening time “O” is measured from the moment the coil supply is switched off to the moment the main poles separate.
Type integral 32 integral 63Number of poles 3 and 4 3
Rated operational current (Ie) A 32 in AC-43 63 in AC-3Rated operational voltage (Ue) V 690 690
Electrical durability, AC-43 at 415 V 1.5 million operating cycles 1.2 million operating cyclesMechanical durability at Uc 10 million operating cycles 5 million operating cycles
Maximum operating rate " 3600 operating cycles/hour 3600 operating cycles/hourat ambient temperature ≤ 55 °C $ With converter 600 operating cycles/hour 600 operating cycles/hour
Environment
Conforming to standards IEC : 947-1, 047-2, 947-3, 947-4-1, 947-6-2VDE : 0100, 0110, 0113, 0170, 0171, 471, 0660BS : 5424, 4752, 4941NEN, NBN
Product certifications ASE, ASEFA, ASTA, BV, CSA, DEMKO, DNV, GL, NEMKO, NKK, ÖVE, RINA, SCC, SETI, UL, USSR, LROS, PTB, SEMKO LROS pending
Protective treatment “TH” “TH”
Ambient air temperature " Operation °C - 25…+ 60 - 20…+ 60around the device Storage °C - 40…+ 80 - 40…+ 80
$ Operation °C - 25…+ 50 - 25…+ 50(1) With converter (1) Storage °C - 25…+ 70 - 25…+ 70
Vibration resistance 5…100 Hz Energised state : 3 gn Energised state : 3 gn Permissible acceleration De-energised state : 3 gn De-energised state : 3 gn
Shock resistance Impulse duration : 11 ms Energised state : 8 gn Energised state : 8 gn Permissible acceleration De-energised state : 8 gn De-energised state : 8 gn
Degree of protection To IEC 144 and 529 IP 20B IP 20BTo VDE 0106 Protection against direct finger contact Protection against direct finger contact
Flame resistance Conforming to IEC 295-2-1, NF C 20-455 and the requirement of 22-12-81 (JO 27 NC of the 1st and 2/2/1982), UL 94 - V0 and NF T 51-072
Maximum operating altitude Without derating m 3000 3000
Operating position In relation to From(without derating) normal vertical main axis
mounting plane (left-right tilt)
From Fromfixing plane main axis(fore-aft tilt) (left-right tilt)
Control circuit characteristics
Rated control " 50 Hz V 21…660 24…660circuit voltage (Uc) " 60 Hz V 21…600 24…600
$ With converter V 24, 48, 110 24, 48, 110
Voltage limits Operating 0.85…1.1 Uc 0.85…1.1 Ucat θ ≤ 55 °C Drop-out 0.25…0.7 Uc 0.25…0.7 Uc
Average consumption " Inrush VA 160 (50 Hz), 185 (60 Hz) 375 (50 Hz), 450 (60 Hz)at 20 °C and at Uc Sealed VA 12 (50 or 60 Hz) 25 (50 or 60 Hz)
$ With Inrush W 250 duration 50 ms 300 duration 50 msconverter Sealed W 4 8
Heat dissipation " 50 Hz W 4 (50 Hz), 5 (60 Hz) 8 (50 Hz), 11 (60 Hz)
Operating time (2) " 50/60 Hz “C” ms 9…25 12…35at 20 °C and at Uc “O” ms 7…20 7…20
$ With “C” ms 25…35 25…40converter “O” ms 10…20 15…25
Characteristics Enclosed starters 2
integral 32 and 63 contactor breakers and reversing contactor breakers
References : pages 21019/2 to 21017/
5Dimensions :
page 21013/2Schemes :
page 21013/3
21015_Ver3.11-EN.fm/3Schneider Electric
Enclosed starters 2
integral 32 and 63 contactor breakers and reversing contactor breakers
(1) Above this value, the breaker trips.(2) Conforming to BS 4752 : 36 kA cycle P2, 50 kA cycle P1.(3) Cos ϕ 0.7.(4) Usual setting range 9…10 Irth max.
Type integral 32 integral 63
Pole characteristics
Rated thermal current (Ith) θ ≤ 40 °C A 32 63Frequency limits ofoperational current Hz 40…60 40…60Rated impulsewithstand voltage (Uimp) Conforming to IEC 947-4 kV 8 8
Rated insulation voltage (Ui) Conforming to IEC 947-1 V 690 690
Heat dissipation in the power Operational current A 1.6 2.5 4 6.3 10 16 25 32 25 32 40 50 63circuits of the contactor breakerand its protection module Power per pole, hot state W 1.6 1.8 1.8 2 2 3.4 4.8 6 4.4 5 5.8 7 9
Rated making I rms Conforming to IEC 947-4 A 12 x Ith (1) 12 or 15 x Ith (1)capacity I peak Conforming to IEC 947-2 kA 105 105
220/ 380/ 440 480/ 600/ 220/ 380/ 440 480/ 600/Rated breaking capacity Operating voltage V 240 415 525 690 240 415 525 690Conforming to IEC 947-2 Value of cos ϕ 0.25 0.25 0.25 0.3 0.8 0.25 0.25 0.25 0.25 0.5
Icu (O-t CO) kA rms 50 50 50 (2) 20 5 (3) 50 50 40 35 10Ics (O-t-CO-t-CO) kA rms 50 50 35 (2) 20 5 50 50 40 35 10
Conforming to IEC 947-6-2 Icu = Ics (O-t-CO-t-rCO) kA rms 50 50 50 15 4 50 50 50 30 10ensuring continuity of service O : breaking short-circuit current (open) ; t : time
CO : closing on short-circuit, breaking short-circuit current (closed-open) (manual)rCO : closing on short-circuit, breaking short-circuit current (remote control)
Total breaking time ms 4 4
Maximum let-through energy With Isc max. at 415 V, 50 Hz A2s 100 x 103 300 x 103
Cabling Maximum c.s.a. Minimum c.s.a. Maximum c.s.a Minimum c.s.a.Flexible cable without cable end mm2 1 x 10 or 2 x 6 1 x 1 1 x 50 or 2 x 35 1 x 6Flexible cable with cable end mm2 1 x 6 or 2 x 4 1 x 1 2 x 25 1 x 6Solid cable mm2 1 x 10 or 2 x 6 1 x 1 1 x 50 1 x 6
Tightening torque N.m 2 6
Characteristics of thermal-magnetic or magnetic only protection modules
LB1- LB6- LB1- LB1- LB1- LB6- LB1-Type LC03M LC03M LC//L LD03P LD03M LD03P LD03L
Standard motors, frequent Standard Frequent Distrib. Standard Standard Frequent Distrib.Protection starting, distribution circuits motors starting circuits motors motors starting circuits
Conforming to standards IEC 947-4 type 2 (lq = 50 kA) and NF C 63-650 63-650 63-120 63-650 63-650 63-650 63-120
Number of poles 3 3 3 4 4 3 3 3 3Number of protected poles 3 3 3 4 4 3 3 3 3Rated operational voltage V 690 690 690 690 690 690 690Maximum continuous current A 0.4…32 0.4…32 10…32 13…63 13…63 13…63 13…63
Thermal protection Setting range (Irth min./Irth max.) A 0.25/0.40 – 6.3/10... 10/13... 10/13... – 10/13...…23/32 23/32 45/63 45/63 45/63
Temperature compensation °C - 20…+ 60Protection against phaseimbalance With Without Without With With Without WithoutTripping class 10 – – 20 20 – –
Magnetic protection Instantaneous trip current Irth 6…12 6…12 3…6 Fixed at 6…12 6…12 3…6conforming to IEC 947-1/2/4/6-2 setting range max. (4) 15 (4)
Tripping tolerance ± 20 %
Characteristics of versions with control test function, with padlocking facility
Conforming to standards IEC 947, NF C 63-130, VDE 0660, VDE 0113Rated operational voltage V 690 Mechanical durability Operating cycles 10,000
1, 2 or 3 padlocks (shank Ø 8 mm max. and Ø 5 mm min.). When flushPadlocking facility mounting, interlocking of the enclosure or cabinet door is possible.
Characteristics
References : pages 21019/2 to 21017/
5Dimensions :
page 21013/2Schemes :
page 21013/3
21019_Ver2.10-EN.fm/2 Schneider Electric
(1) Enclosures supplied with drillings and removable blanking plugs for addition of cable glands (to be ordered separately):for number and diameter, see page 21013/2.
Empty metal enclosures
Type of For use Reference Weightenclosure on kg
Degree of protection IP 54 (1) integral 32 LD4 DE1-LT215 2.110with drillings for doorinterlock mechanism(interlock not supplied).For customer assembly
LD5 DE1-LT225 2.710
integral 63 LD4 DE1-LT315 3.510
References Enclosed starters 2
integral 32 and 63 contactor breakers and reversing contactor breakersEnclosures
DE1-LT215
Dimensions :page 21013/2
21019_Ver2.10-EN.fm/3Schneider Electric
Enclosed starters 2
integral 32 and 63 contactor breakers and reversing contactor breakersDoor interlock mechanisms
Door interlock mechanisms (IP 54)
Type For use on Colour Reference Weightenclosure of knob kg
Non-adjustable DE1-LT215 Red LA9-LC320 0.200
DE1-LT225 Red LA9-LC520 0.200orDE1-LT315
References
Dimensions :page 21013/2
21017_Ver3.11-EN.fm/2 Schneider Electric
Red knob on yellow background (CNOMO) Emergency Stop
Without control test function, with padlocking facility
Red knob on yellow background (CNOMO) Emergency Stop
(1) For the unit to function, it must be fitted with a protection module, to be ordered separately.(2) Standard control circuit voltages (for other voltages, please consult your Regional Sales Office).
(3) For use on d.c., the unit is supplied with 1 or 2 converters, including coil suppression devices. (2 converters forreversing contactor breakers.
3-pole contactor breakers without protection module (1)
Standard power ratings of 3-phase Opera- Breaking Basic reference. Weightmotors 50/60 Hz in category AC-43 tional capacity Complete with
current (Iq) code indicating for control circuit
220 V 400 V Ue ≤ 415 V voltage240 V 415 V 440 V 500 V 660 V (2)kW kW kW kW kW A kA kg
Without control test function, with padlocking facility
7.5 15 15 18.5 25 32 50 LD4-LC030/ 1.450
15 30 33 37 55 63 50 LD4-LD030/ 3.80033
3-pole reversing contactor breakers without protection module (1)
7.5 15 15 18.5 25 32 50 LD5-LC030/(4) 2.800
15 30 33 37 55 63 50 LD5-LD030/ (4) 7.60033
Volts 24 36 42 48 110 120 220 230 240 380 415 440 480 500 600 660400
50 Hz LD/-LC, LD B – D E F – M M U Q N N – S – Y
60 Hz LD/-LC BC CC – D FC FC MC MC/PU7 MC – – Q Q – S –LD/-LD BC CC – CE K FC LC MC MC – – UX Q – S –
$ (3) LD/-LC, LD, BD – – ED FD – – – – – – – – – – –
(4) It is essential to provide electrical locking for reversing contactor breakers integral 32.
Enclosed starters 2
integral 32 and 63 contactor breakers and reversing contactor breakers for the control and protection of motors
References
LD4-LC030/
Dimensions :page 21013/2
Schemes :pages 21013/2 and 21013/3
LD5-LC030/
21017_Ver3.11-EN.fm/3Schneider Electric
Fixed magnetic protection, set at 15 Irth max, for mounting on integral 63
Adjustable magnetic protection from 6 to 12 Irth max, for mounting on integral 32
Adjustable magnetic protection from 6 to 12 Irth max, for mounting on integral 63
Adjustable magnetic protection from 6 to 12 Irth max, for mounting on integral 63
( There are no standard power ratings for these motors.
Thermal-magnetic protection modules (compensated and differential for normal starting motors)
Standard power ratings of 3-phase Thermal Magnetic Reference Weightmotors 50/60 Hz in category AC-3 setting setting
range range220 V 400 V 480 600 V (Irth min 240 V 415 V 440 V 525 V 690 V to Irth max)kW kW kW kW kW A A kg
3 5.5 5.5 7.5 10 10...13 – LB1-LD03P16 0.7804 9 9 11 15 13...18 – LB1-LD03P21 0.7805.5 11 11 15 18.5 18...25 – LB1-LD03P22 0.7807.5 15 15 18.5 22 23...32 – LB1-LD03P53 0.7809 22 22 25 33 28...40 – LB1-LD03P55 0.78011 25 25 33 45 35...50 – LB1-LD03P57 0.78015 33 33 40 55 45...63 – LB1-LD03P61 0.780
0.06 ( ( ( ( 0.25...0.4 2.4...4.8 LB1-LC03M03 0.400( ( ( ( ( 0.4...0.63 3.8...7.6 LB1-LC03M04 0.4000.090.12 ( 0.37 0.37 0.55 0.63...1 6...12 LB1-LC03M05 0.4000.180.25 ( 0.55 0.75 1.1 1...1.6 9.5...19 LB1-LC03M06 0.4000.37 1.1 1.1 1.1 1.5 1.6...2.5 15...30 LB1-LC03M07 0.4000.550.75 1.5 1.5 2.2 3 2.5...4 24...48 LB1-LC03M08 0.4001.1 2.2 2.2 3.7 4 4...6.3 38...76 LB1-LC03M10 0.4001.52.2 4 4 5.5 7.5 6.3...10 60...120 LB1-LC03M13 0.40034 7.5 7.5 10 11 10...16 95...190 LB1-LC03M17 0.4005.5 11 11 15 18.5 16...25 150...300 LB1-LC03M22 0.4007.5 15 15 18.5 25 23...32 190...380 LB1-LC03M53 0.400
3 5.5 5.5 7.5 10 10...13 78...156 LB1-LD03M16 0.7804 9 9 11 15 13...18 108...216 LB1-LD03M21 0.7805.5 11 11 15 18.5 18...25 150...300 LB1-LD03M22 0.7807.5 15 15 18.5 22 23...32 190...380 LB1-LD03M53 0.7809 22 22 25 33 28...40 240...480 LB1-LD03M55 0.78011 25 25 33 45 35...50 300...600 LB1-LD03M57 0.78015 33 33 40 55 45...63 380...760 LB1-LD03M61 0.780
Magnetic only protection modules (for frequent starting motors)
Adjustable magnetic protection from 6 to 12 Irth max, for mounting on integral 320.18 0.25 ( 0.55 0.75 1.1 – 9.5...19 LB6-LC03M06 0.4000.37 1.1 1.1 1.1 1.5 – 15...30 LB6-LC03M07 0.4000.550.75 1.5 1.5 2.2 3 – 24...48 LB6-LC03M08 0.4001.1 2.2 2.2 3.7 4 – 38...76 LB6-LC03M10 0.4001.52.2 4 4 5.5 7.5 – 60…120 LB6-LC03M13 0.40034 7.5 7.5 10 11 – 95...190 LB6-LC03M17 0.4005.5 11 11 15 18.5 – 150...300 LB6-LC03M22 0.4007.5 15 15 18.5 25 – 190...380 LB6-LC03M53 0.400
3 5.5 5.5 7.5 10 – 78...156 LB6-LD03M16 0.7804 9 9 11 15 – 108...216 LB6-LD03M21 0.7805.5 11 11 15 18.5 – 150...300 LB6-LD03M22 0.7807.5 15 15 18.5 22 – 190...380 LB6-LD03M53 0.7809 22 22 25 33 – 240...480 LB6-LD03M55 0.78011 25 25 33 45 – 300...600 LB6-LD03M57 0.78015 33 33 40 55 – 380...760 LB6-LD03M61 0.780
Enclosed starters 2
integral 32 and 63 contactor breakers and reversing contactor breakers for the control and protection of motors (for customer assembly)
References
Dimensions :page 21013/2
Schemes :pages 21013/2 and 21013/3
LB1-LC03M
LB6-LC03M//
21017_Ver3.11-EN.fm/4 Schneider Electric
Without control test function, with padlocking facility
Red knob on yellow background (CNOMO) Emergency Stop
Thermal-magnetic (compensated)
to Irth max)
For integral 32
For integral 63
(1) For the unit to function, it must be fitted with a protection module, to be ordered separately.(2) Standard control circuit voltages (for other voltages, please consult your Regional Sales Office).
(3) For use on d.c., the unit is supplied with a converter, including coil suppression device.
3 and 4-pole contactor breakers without protection module (1)
Rated Maximum Maximum Breaking Number Basic reference. Weightthermal opera- operational capacity of Complete current tional voltage (Iq) poles with codeIth current for indicatingθ ≤ 40 °C AC-1 Ue ≤ 415 V control circuit
θ ≤ 40 °C voltage (2)A A V kA kg
32 32 690 50 3 LD4-LC030/ 1.4504 LD4-LC040/ 1.780
63 63 690 50 3 LD4-LD030/ 3.800
Protection modules (for customer assembly)
Thermal Magnetic Number Number Reference Weightsetting setting of of range range poles protected(Irth min (3...6 Irth max) poles
A A kg
6.3...10 30...60 3 3 LB1-LC03L13 0.4004 4 LB1-LC04L13 0.500 3 LB1-LC05L13 0.500
10...16 48...95 3 3 LB1-LC03L17 0.4004 4 LB1-LC04L17 0.500 3 LB1-LC05L17 0.500
16...25 75...150 3 3 LB1-LC03L22 0.4004 4 LB1-LC04L22 0.500 3 LB1-LC05L22 0.500
23...32 95...190 3 3 LB1-LC03L53 0.4004 4 LB1-LC04L53 0.500 3 LB1-LC05L53 0.500
10...13 39...78 3 3 LB1-LD03L16 0.780
13...18 54...108 3 3 LB1-LD03L21 0.780
18...25 75...150 3 3 LB1-LD03L22 0.780
23...32 95...190 3 3 LB1-LD03L53 0.780
28...40 120...240 3 3 LB1-LD03L55 0.780
35...50 150...300 3 3 LB1-LD03L57 0.780
45...63 190...380 3 3 LB1-LD03L61 0.780
Volts 24 36 42 48 110 120 220 230 240 380 415 440 480 500 600 660400
50 Hz LD/-LC, LD B – D E F – M M U Q N N – S – Y
60 Hz LD/-LC BC CC – D FC FC MC MC MC – – Q Q – S –LD/-LD BC CC – CE K FC LC MC MC – – UX Q – S –
$ (3) LD/-LC, LD BD – – ED FD – – – – – – – – – – –
Enclosed starters 2
integral 32 and 63 contactor breakers and reversing contactor breakers for control and protection of resistive circuits in category AC-1
References
Dimensions :page 21013/2
Schemes :pages 21013/2 and 21013/3
LD4-LC040
LB1-LD03L//
21017_Ver3.11-EN.fm/5Schneider Electric
(2) Standard control circuit voltages (for other voltages, please consult your Regional Sales Office)
Instantaneous auxiliary contact blocks (IP 20)
For use Type and number Composition Reference Weighton of blocks per unit
kg
LD4 or LD5 1 block of 6 instantaneous contacts LA1-LC010 0.280Mounted on comprising:RH side 3 signalling contacts “contactor state” 2 1 –
1 signalling contact “tripped – – 1 on short-circuit”1 signalling contact “tripped” – – 1 1 signalling contact “control knob – – 1 in any position other than “Auto””
1 block of 5 instantaneous contacts LA1-LC012 0.220comprising: 3 signalling contacts “contactor state” 2 1 –1 signalling contact “tripped” 1 – –1 signalling contact “tripped” 1 – –on short-circuit
Isolating blocks
LD4 1 control circuit isolating block 1 – – LA1-LC030 0.035Mounted on (1 or 2 blocks per unit)LH side
LD5 1 control circuit isolating block 2 – – LA1-LC031 0.100Mounted onLH side
Electrical tripping devices
For use Type and number Function Basic reference. Weighton per device Complete with
code indicatingcontrol circuitvoltage (2)
LD4 or LD5 1 tripping block for operation Time delay LA1-LC070/ 0.150fitted with an on de-energisation 0.2 sLA1-LC010 (undervoltage trip)or Instantaneous LA1-LC072/ 0.150LA1-LC012add-on block
or 1 tripping block for operation Instantaneous LA1-LC071/ 0.150on energisation (shunt trip)
Remote electrical reset devices
For use Type and number Control Reference Weighton per device voltage kg
LD4 or LD5 1 remote electrical 24 V 50/60 Hz LA1-LC052B 0.320fitted with an reset blockLA1-LC010or 42 V 50 Hz LA1-LC052E 0.320LA1-LC012 48 V 50/60 Hzadd-on block
100/127 V LA1-LC052F 0.32050/60 Hz
200/240V LA1-LC052M 0.32050/60 Hz
Volts 24 48 110 120 220/230 240 380/400 415 44050 Hz B E F – M U Q N N60 Hz B E F F M M Q – N
Enclosed starters 2
integral 32 and 63 contactor breakers and reversing contactor breakers Auxiliary contact blocks and accessories
References
integral +LA1-LC030
integral +LA1-LC012 +LA1-LC052/
integral +LA1-LC010 +LA1-LC070/
Dimensions :page 21013/2
Schemes :pages 21013/2 and 21013/3
21013_Ver2.10-EN.fm/2 Schneider Electric
c
b
69
a
=
195
105= =
=
a
DE1-LT315
DE1-LT225
=
H
G=
==
114
123
280
183
2xØ5,5
=
122
260
= =
=
= =28
105
90
==
243
6359 59
105
105
181
45
275
174 (LD5)54
65
105
105
172 (LD4)19= =
80
66
==
38= =
80
85
52 33
85= =
80
132
99 33
8080
135
182
54
65
= =
==
54
54
1/L1
3/L2
5/L3
N1
2/T
1
4/T
2
6/T
3
N2
A2A1 2/
T1
4/T
2
6/T
3
2/T
1
4/T
2
6/T
35/
L3
3/L2
1/L1
A2A1
Q1
2/T
1
4/T
2
6/T
3
Dimensions
Non-adjustable door interlock mechanism LA9-LC52/
Door drillings
SchemesContactor breakers with protection module LB/
Metal enclosures, degree of protection IP54 Insulated enclosure DE1-LT215 DE1-LT225, LT315 DE1-LC001
DE1- a b c G HLT215 181 312 150 105 195LT225 257 307 165 165 165LT315 287 367 190 195 225 .
integral 32 integral 63For mounting on LD4-LC030 and LC040, LD5-LC030 For mounting on LD4-LD030 and LD5-LD030
LD4-LC030 LD4-LC040 LD5-LC030 LD4-LD030 LD5-LD030
integral 32 integral 63LD4-LC0/0 + LB1-LC0// LB6-LC03M LD4-LD030 + LB1-LD03/ LB6-D03M
Enclosed starters 2
integral 32 and 63 contactor breakers and reversing contactor breakers Enclosures
Dimensions, schemes
Number of blanked-off cable entries At cable ∅ For cable gland
DE1- top bottom min max N° TypeLT215 2 1 10 12 13 13M
1 2 14 18 21 21MLT225 1 2 10 12 13 13M
1 2 14 18 21 21MLT315 1 2 10 12 13 13M
1 2 24 30 36 36M
References :pages 21019/2 to 21017/5
thickness 5 mm max.
thickness 5 mm max.
21013_Ver2.10-EN.fm/3Schneider Electric
2/T
1
4/T
2
6/T
3
1/L1
3/L2
5/L3
A2 A1
A2 A1
2/T
1
4/T
2
6/T
3
2/T
1
4/T
2
6/T
3
1/L1
3/L2
5/L3
A2 A1
A2 A1
2/T
1
4/T
2
6/T
3
13 23 31
14 24 32
1314
3132
9598
1314
3132
4142
LA1 - LC010 LA1 - LC012 LA1 - LC020 LA1 - LC001
9895
96
0805
0618
15
160Auto +
2324
0508
2324
1314
3132
LA1 - LC025
2324
9895
9695
ou
ou
5453
5453(6
3)(6
4)
LA1 - LC030
MB4
B2
B3
B1
5453
6463
LA1 - LC031 Sectionnement
C1
C2
D1
D2
U<
Enclosed starters 2
integral 32 and 63 contactor breakers and reversing contactor breakers
Reversing contactor breakers with protection module LB/
Add-on blocks, integral 32 and 63
integral 32 integral 63LD5-LC030 + LB1-LC03M LD5-LD030 + LB1-LD03M or P
LB6-LC03M LB6-LD03M
For contactor breaker LD4 and reversing contactor breaker LD5 For contactor breaker LD4Mounted on RH side Mounted on LH side
For Reversing contactor breakers LD5 Tripping devices (1) Remote electrical reset devices (1)Mounted on LH side for LD4, LD5 for LD4, LD5
LA1-LC071 LA1-LC070, LC072 LA1-LC052/
(1) For contactor breakers and reversing contactor breakers already fitted with an LA1-LC010 or LA1-LC012instantaneous auxiliary contact block.
Schemes
References :pages 21017/2 to 21017/
5Dimensions :
page 21013/2
Control knobposition signalling
Short-circuitsignalling
Trip signalling
Breaker
Isolator
1 or 2 LA1-LC030
AutoTRIP + RESET
Isolator
24026-EN_Ver5.1.fm/2
LG7-K06
LG7-D12with padlocking facility fitted as standard
Safety control and protection solutions 4
Enclosed D.O.L. starters for motor controlfor use on a machine subject to the applicationof Machinery Directive 98/37/CE (1)
Functions performed by the starter:- isolation,- locking of isolation fitted as standard as from LG7-K09,- lockable Emergency Stop (1/4 turn) (3),- short-circuit protection,- overload protection,- pushbutton control: 1 white Start button “I” and 1 black Stop button “O”,- degree of protection of enclosure IP 657, double insulatedSwitching back on of power supply after tripping must be by a deliberate action.A GV2-SN indicator light may be added (to be assembled by customer), please consult your Regional Sales Office.For supply voltages between 380 and 415 V (codes Q7, V7 or N7) the control circuit is pre-wired between phases; for other supply voltages, the control circuit must be wired by the customer.
See page 24026/5.
(1) Compliance with a harmonised European standard assumes conformity with the corresponding directive, providedthat installation, building in and/or assembly of the starter is carried out correctly by the machine manufacturer.Harmonised European standards: EN 60947 and EN 60439.Conformity to international standards: IEC 947 and IEC 439.(2) Standard control circuit voltages (for other voltages, please consult your Regional Sales Office).
(3) LG7-K06: the mushroom head type Emergency Stop acts mechanically on the circuit breaker.LG7-K09, D12, D18: the Emergency Stop function is provided by an undervoltage coil, acting on the circuit breaker. Thiscoil is always supplied pre-wired for use on 380/415 V 50 Hz. For a 60 Hz supply, please consult your Regional SalesOffice.
Non reversing starters (with pushbutton control of isolation)
Standard power ratings Circuit breaker Dust & damp protected starter Weightof 3-phase motors 50/60 Hz Setting range Basic reference.in category AC-3 of thermal trips Complete with
code indicating220/ 400/ control circuit230 V 415 V 440 V voltage (2) (3)kW kW kW A kg
– 0.06 0.06 0.16…0.25 LG7-K0602 1.300
0.06 0.09 0.12 0.25…0.40 LG7-K0603 1.300
– 0.18 0.18 0.40…0.63 LG7-K0604 1.300
0.12 0.25 0.25 0.63…1 LG7-K0605 1.300
0.25 0.55 0.55 1…1.6 LG7-K0606 1.300
0.37 0.75 1.1 1.6…2.5 LG7-K0607 1.300
0.75 1.5 1.5 2.5…4 LG7-K0608 1.300
1.1 2.2 3 4…6.3 LG7-K0610 1.300
1.5 4 4 6…10 LG7-K0914 1.450
3 5.5 5.5 9…14 LG7-D1216 1.600
4 7.5 9 13…18 LG7-D1820 1.630
9 9 17…23 LG7-D1821 1.630
Specifications
Variants (pre-assembled)
LG7-KVolts 12 24 36 42 48 110 127 220/ 230 230/ 380/ 400 400/ 440 500 660/50/60 Hz 230 240 400 415 690Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7
LG7-DVolts 24 42 48 110 220/ 230 240 380/ 400 415 44050/60 Hz 230 400Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7
Other versions Starters for voltages other than those indicated above.Please consult your Regional Sales Office.
References 0
Dimensions :page 24028/2
Schemes :page 24028/3
24026-EN_Ver5.1.fm/3
LG1-K
Safety control and protection solutions 4
Enclosed D.O.L. starters for motor controlfor use on a machine subject to the applicationof Machinery Directive 98/37/CE (1)
Enclosure cannot be opened when energised in position “I”.
Functions performed by the starter:- isolation,- locking of isolation,- lockable Emergency Stop (red/yellow switch disconnector),- short-circuit protection,- overload protection,- pushbutton control: 1 white Start button “I” and 1 black Stop button “O”,- degree of protection of enclosure: IP 657, double insulated,Switching back on of power supply after tripping must be by a deliberate action.A GV2-SN indicator light may be added (to be assembled by customer), please consult your Regional Sales Office. For supply voltages between 380 and 415 V (codes Q7, V7 or N7) the control circuit is pre-wired between phases; forother supply voltages, the control circuit must be wired by the customer.
See page 24026/5.
(1) Compliance with a harmonised European standard assumes conformity with the corresponding directive, providedthat installation, building in and/or assembly of the starter is carried out correctly by the machine manufacturer.Harmonised European standards: EN 60947 and EN 60439.Conformity to international standards: IEC 947 and IEC 439.(2) Standard control circuit voltages (for other voltages, please consult your Regional Sales Office).
Non reversing starters (with rotary operator for control of isolation)
Standard power ratings Circuit breaker Dust & damp protected starter Weightof 3-phase motors 50/60 Hz Setting range Basic reference.in category AC-3 of thermal trips Complete with
code indicating220/ 400/ control circuit230 V 415 V voltages (2)kW kW kW A kg
– 0.06 0.06 0.16…0.25 LG1-K06502 0.970
0.06 0.09 0.12 0.25…0.40 LG1-K06503 0.970
– 0.18 0.18 0.40…0.63 LG1-K06504 0.970
0.12 0.25 0.25 0.63…1 LG1-K06505 0.970
0.25 0.55 0.55 1…1.6 LG1-K06506 0.970
0.37 0.75 1.1 1.6…2.5 LG1-K06507 0.970
0.75 1.5 1.5 2.5…4 LG1-K06508 0.970
1.1 2.2 3 4…6.3 LG1-K06510 0.970
1.5 4 4 6…10 LG1-K09514 1.120
3 5.5 5.5 9…14 LG1-D12216 1.270
4 7.5 9 13…18 LG1-D18220 1.290
9 9 17…23 LG1-D18221 1.290
Specifications
Variants (pre-assembled)
LG1-K Volts 12 24 36 42 48 110 127 220/ 230 230/ 380/ 400 400/ 440 500 660/50/60 Hz 230 240 400 415 690Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7
LG1-DVolts 24 42 48 110 220/ 230 240 380/ 400 415 44050/60 Hz 230 400Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7
Other versions Starters for voltages other than those indicated above.Please consult your Regional Sales Office.
References (continued) 0
Dimensions :page 24028/2
Schemes :page 24028/3
24026-EN_Ver5.1.fm/4
LG8-K09with padlocking facilityfitted as standard
LG8-K06
Functions performed by the starter:- isolation,- locking of isolation fitted as standard as from LG8-K09,- Emergency Stop (3),- short-circuit protection,- overload protection,- control by selector switch “1-2”, position non maintained,- degree of protection of enclosure IP 657, double insulated.Switching back on of power supply after tripping must be by a deliberate action.A GV2-SN indicator light may be added (to be assembled by customer), please consult your Regional Sales Office.For supply voltages between 380 and 415 V (codes Q7, V7 or N7) the control circuit is pre-wired between phases; for other supply voltages, the control circuit must be wired by the customer.
See page 24026/5.
(1) Compliance with a harmonised European standard assumes conformity with the corresponding directive, providedthat installation, building in and/or assembly of the starter is carried out correctly by the machine manufacturer.Harmonised European standards: EN 60947 and EN 60439.Conformity to international standards: IEC 947 and IEC 439.(2) Standard control circuit voltages (for other voltages, please consult your Regional Sales Office).
(3) LG8-K06: The mushroom head type Emergency Stop acts mechanically on the circuit breaker.LG8-K09: the Emergency Stop function is provided by an undervoltage coil, acting on the circuit breaker. This coil isalways supplied pre-wired for use on 380/415 V 50 Hz. For a 60 Hz supply, please consult your Regional Sales Office.
Reversing starters (with pushbutton control of isolation)
Standard power ratings Circuit breaker Dust & damp protected starter Weightof 3-phase motors 50/60 Hz Setting range Basic reference.in category AC-3 of thermal trips Complete with
code indicating220/ 400/ control circuit230 V 415 V 440 V voltage (2)kW kW kW A kg
– 0.06 0.06 0.16…0.25 LG8-K0602 1.640
0.06 0.09 0.12 0.25…0.40 LG8-K0603 1.640
– 0.18 0.18 0.40…0.63 LG8-K0604 1.640
0.12 0.25 0.25 0.63…1 LG8-K0605 1.640
0.25 0.55 0.55 1…1.6 LG8-K0606 1.640
0.37 0.75 1.1 1.6…2.5 LG8-K0607 1.640
0.75 1.5 1.5 2.5…4 LG8-K0608 1.640
1.1 2.2 3 4…6.3 LG8-K0610 1.640
1.5 4 4 6…10 LG8-K0914 (3) 1.640
3 5.5 5.5 9…14 LG8-K1216 (3) 1.640
Specifications of reversing starters
Variants (pre-assembled)
Volts 12 24 36 42 48 110 127 220/ 230 230/ 380/ 400 400/ 440 500 660/50/60 Hz 230 240 400 415 690Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7
Other versions Starters for voltages other than those indicated above.Starters for higher power ratings.Please consult your Regional Sales Office.
Safety control and protection solutions 4
Enclosed D.O.L. starters for motor controlfor use on a machine subject to the applicationof Machinery Directive 98/37/CE (1)
References (continued) 0
Dimensions :page 24028/2
Schemes :page 24028/3
24026-EN_Ver5.1.fm/5
Safety control and protection solutions 4
Enclosed D.O.L. starters for motor controlfor use on a machine subject to the applicationof Machinery Directive 98/37/CE (1)
(1) Compliance with a harmonised European standard assumes conformity with the corresponding directive, providedthat installation, building in and/or assembly of the starter is carried out correctly by the machine manufacturer.Harmonised European standards: EN 60947 and EN 60439.Conformity to international standards: IEC 947 and IEC 439.(2) Example: LG7-D12M716A04.(3) Delete the last two digits of the selected starter reference. Example: LG1-K06508 becomes LG1-K065(4) Example: LG8-K095A04A39A59.(5) LG1-K06: The mushroom head type Emergency Stop acts mechanically on the circuit breaker.LG1-K09, D12, D18: the Emergency Stop function is provided by an undervoltage coil, acting on the circuit breaker. Thiscoil is always supplied pre-wired for use on 380/415 V 50 Hz. For a 60 Hz supply, please consult your Regional SalesOffice.
Variants
Description For use on Suffix to be addedto starter reference (2)
With Emergency Stop LG1, LG7, LG8 A04No control pushbuttons
With Emergency Stop LG8-K06 A102 pushbuttons with arrows “” and “” (latching)1 Stop button “O”
Without Emergency Stop LG8 A142 pushbuttons with arrows “” and “” (non latching)Without Stop button
With Emergency Stop, LG1 A37mushroom head
Without Emergency Stop LG7, LG8 A39(when the Emergency Stopis on the machine)
With padlocking facility LG1-K06, LG7-K06 A29(fitted as standard as from LG1-K09 or LG7-K09)
1 neutral terminal LG1, LG7, LG8 A59Fitted as standard on starters orderedfor use on 240 V (U7) supply
Short-circuit LG7 A12signalling block
Vacuum valve LG7-D A40for compressor
Without circuit breaker LG1, LG7, LG8 (3)
Possible combinations of variants for the selected starter type (4)
Starter type A04 A10 A12 A14 A29 A37 A39 A40 A59
LG1-K (5)
LG7-K06
LG7-K09
LG7-D12
LG8-K06
LG8-K09
Combination possible Combination not possible
References (continued) 0
24028-EN_Ver2.13.fm/2
120
165
84
17515
0
165
146 (2)
120
177 (1)
84
175
150
165
(1)
(2)
(3)
Safety control and protection solutions 4
Enclosed D.O.L. starters for motor controlfor use on a machine subject to the applicationof Machinery Directive 98/37/CE
Starters without isolator LG1-K06, K09 LG7-K06, K09, D12, D18LG1-D12, D18 LG8-K06, K09, K12
Knock-outs or blanking plugs for cable glands (1) Emergency Stop for starters < 3 kWType of enclosure At At (2) Emergency Stop for starters ≥ 3 kW
top bottom (3) Only for LG7LG1-K and LG1-D 2 x 13 P and 2 x 16 P 2 x 13 P and 2 x 16 PLG7-K and LG7-D 2 x 13 P and 2 x 16 P 2 x 13 P and 2 x 16 PLG8-K 2 x 13 P and 2 x 16 P 2 x 13 P and 2 x 16 P
Dimensions 0
References :pages 24026/2 to 24026/5
Schemes :page 24028/3
24028-EN_Ver2.13.fm/3
D.O.L. starters
Reversing starters
LG1-K06, K09, D12, D18 LG1-K06, K09, D12, D18380/400 V, code Q7 or 400/415 V, code N7220/230 V, code M7
LG7-K06 LG7-K09, D12, D18 LG7-K06, K09, D12, D18380/400 V, code Q7 or 400/415 V, code N7220/230 V, code M7
LG8-K06 LG8-K09, K12 LG8-K06, K09, K12380/400 V, code Q7 or 400/415 V, code N7220/230 V, code M7
1/L1
– Q1
3/L2
5/L3
U WV
– KM1 – KM2
1 3 5 1 3 5
2 4 6 2 4 6
2 4 6
2 4 6
1/L1
3/L2
5/L3
– KM1
12
34
56
U1
W1
V1
– Q1
L3T
3
L2T
2
L1T
1
– Q1
1 3 5
2
– Q2
4 6
– KM1
12
34
56
U1
W1
V1
KM1/1
KM1/5
– KM1
– KM1
– S2
1314
1314
1112
A2
A1
– S1
Ph
N
11
KM2/5
KM2/1
– KM1
– KM2– KM1
12
1314
5453
– KM2
2122
A1
A2
A1
A2
– S1
– S21 0
– KM2
1314
5453
– KM1
2122
– S220
Ph
N
1/L1
3/L2
5/L3
U WV
– KM1 – KM2
1 3 5 1 3 5
2 4 6 2 4 6
2 4 6
D1
D2
E1
E2
1/L1
– Q1
3/L2
5/L3
– F1
U1
W1
V1
– KM1
1 3 5
2 4 6
2 4 6
D1
D2
E1
E2
KM1/1
KM1/5
– KM1
– KM1
– S213
14
1314
1112
A2
A1
– S1
Ph
N
– Q1
Safety control and protection solutions 4
Enclosed D.O.L. starters for motor controlfor use on a machine subject to the applicationof Machinery Directive 98/37/CE
Schemes 0
References :pages 24026/2 to 24026/5
Dimensions :page 24028/2
26044-EN_Ver3.3.fm/2
LJ7-K
Safety control and protection solutions 4
Enclosed D.O.L. starters for motor controlfor use on a machine subject to the application of Machinery Directive 98/37/CE
Compliance with a harmonised European standard assumes conformity with the corresponding directive, provided thatthe installation, building in and/or assembly of the starter is carried out correctly by the machine manufacturer.Harmonised European standards: EN 60947 and EN 60439.Conformity to international standards: IEC 947 and IEC 439.
Starters pre-wired for operation on a 3-phase 380 to 400 V 50 Hz supply (with pushbutton control of isolator function)
Functions performed by the starter:- isolation,- interlocking of isolator function fitted as standard on LJ7-K09,- lockable Emergency Stop (1/4 turn) (1),- short-circuit protection,- overload protection,- pushbutton control: 1 white Start button “I” and 1 black Stop button “O”,- terminal allowing connection of a volt-free contact, if required, in the control circuit,- degree of protection of enclosure: IP 657, double insulatedReconnection of the power supply after a break must be by means of a deliberate action.A GV2-SN pilot light may be fitted; for customer assembly, please consult your Regional Sales Office.Integral transformer: 400/24 V, 25 VA.
No pushbuttons
(1) LJ7-K06 (P ≤ 3 kW at 400 V): the mushroom head Emergency Stop button acts mechanically on the circuit breaker.LJ7-K09 (P > 3 kW at 400 V): the Emergency Stop function is performed by an undervoltage trip GV2-AX385, acting onthe circuit breaker. The circuit breaker is automatically supplied pre-wired for use on a 380/400 V 50 Hz supply. (2) In the reference, the voltage code Q7 (380/400 V) indicates the power supply voltage to which the starter will beconnected, it being assumed that the contactor has a 24 V coil (see control circuit scheme).(3) Possible combinations of variants A04, A29 and A39 on starters LJ7-K06. Example: LJ7-K06Q702A04A29A39. Possible combination of variants A04 and A39 on starters LJ7-K09Q714A04A39.(4) Example: LJ7-K06Q702A04.(5) Delete the last 2 figures of the selected starter reference. Example: LJ7-K06Q702 becomes LJ7-K06Q7.
Non reversing starters with integral transformer
Standard power ratings of Circuit breaker Starter: IP 657 Weight3-phase motors 50 Hz Setting range Reference (2) in category AC-3 of thermal380/ trips400 VkW A kg
0.06 0.16…0.25 LJ7-K06Q702 2.270
0.09 0.25…0.40 LJ7-K06Q703 2.270
0.18 0.40…0.63 LJ7-K06Q704 2.270
0.25 0.63…1 LJ7-K06Q705 2.270
0.55 1…1,6 LJ7-K06Q706 2.270
0.75 1.6…2.5 LJ7-K06Q707 2.270
1.5 2.5…4 LJ7-K06Q708 2.270
2.2 4…6.3 LJ7-K06Q710 2.270
4 6…10 LJ7-K09Q714 2.270
Specifications
Variants (3)
Description For use on Suffix to be added to starter reference (4)
With Emergency Stop function LJ7 A04
Without Emergency Stop Function LJ7 A39(when Emergency Stop is on the machine)
With padlocking facility LJ7-K06 A29(fitted as standard on LJ7-K09)
Without circuit breaker LJ7 (5)
Other versions Starters for voltages other than those indicated above.Please consult your Regional Sales Office.
References 0
Dimensions :page 26045/2
Schemes :page 26045/3
26044-EN_Ver3.3.fm/3
Safety control and protection solutions 4
Enclosed D.O.L. starters for motor controlfor use on a machine subject to the application of Machinery Directive 98/37/CE
Compliance with a harmonised European standard assumes conformity with the the corresponding directive, providedthat the installation, building in and/or assembly of the starter is carried out correctly by the machine manufacturer.Harmonised European standards: EN 60947 and EN 60439.Conformity to international standards: IEC 947 and IEC 439.
Starters pre-wired for operation on a 3-phase 380 to 400 V 50 Hz supply (with pushbutton control of isolator function)
Functions performed by the starter:- isolation,- interlocking of isolator function fitted as standard on LJ8-K09,- lockable Emergency Stop (1/4 turn) (1),- short-circuit protection,- overload protection,- pushbutton control: 1 white Start button “I” and 1 black Stop button “O”,- terminal allowing connection of a volt-free contact, if required, in the control circuit,- degree of protection of enclosure: IP 657, double insulatedReconnection of the power supply after a break must be by means of a deliberate action.A GV2-SN pilot light may be fitted; for customer assembly, please consult your Regional Sales Office.Integral transformer: 400/24 V, 25 VA.
No pushbuttons
(1) LJ8-K06 (P ≤ 3 kW at 400 V): the mushroom head Emergency Stop button acts mechanically on the circuit breaker.LJ8-K09 (P > 3 kW at 400 V): the Emergency Stop function is performed by an undervoltage trip GV2-AX385, actingon the circuit breaker. The circuit breaker is automatically supplied pre-wired for use on a 380/400 V 50 Hz supply. (2) In the reference, the voltage code Q7 (380/400 V) indicates the power supply voltage to which the starter will beconnected, it being assumed that the contactor has a 24 V coil (see control circuit scheme).(3) Possible combinations of variants A04, A29 and A39 on starters LJ8-K06. Example: LJ8-K06Q702A04A29A39. Possible combination of variants A04 and A39 on starters LJ8-K09. Example: LJ8-K09Q714A04A39.(4) Example: LJ8-K06Q702A04.(5) Delete the last 2 figures of the selected starter reference. Example: LJ8-K06Q702 becomes LJ8-K06Q7.
Reversing starters with integral transformer
Standard power ratings of Circuit breaker Starter: IP 657 Weight3-phase motors 50 Hz Setting range Reference (2) in category AC-3 of thermal380/ trips400 VkW A kg
0.06 0.16…0.25 LJ8-K06Q702 2.650
0.09 0.25…0.40 LJ8-K06Q703 2.650
0.18 0.40…0.63 LJ8-K06Q704 2.650
0.25 0.63…1 LJ8-K06Q705 2.650
0.55 1…1,6 LJ8-K06Q706 2.650
0.75 1.6…2.5 LJ8-K06Q707 2.650
1.5 2.5…4 LJ8-K06Q708 2.650
2.2 4…6.3 LJ8-K06Q710 2.650
4 6…10 LJ8-K09Q714 2.650
Specifications
Variants (3)
Description For use on Suffix to be added to starter reference (4)
With Emergency Stop function LJ8 A04
Without Emergency Stop Function LJ8 A39(when Emergency Stop is on the machine)
With padlocking facility LJ8-K06 A29(fitted as standard on LJ8-K09)
Without circuit breaker LJ8 (5)
Other versions Starters for voltages other than those indicated above.Please consult your Regional Sales Office.
References (continued) 0
Dimensions :page 26045/2
Schemes :page 26045/3
LJ8-K
26045-EN_Ver2.11.fm/2
146
120
84
175
150
165
177
120
84
175
150
165
Safety control and protection solutions 4
Enclosed D.O.L. starters for motor controlfor use on a machine subject to the applicationof Machinery Directive 98/37/CE
LJ7-K06, LJ8-K06
LJ7-K09, LJ8-K09
Cut-outs or blanking plugs for cable glands at the top and at the bottom 2 x 13 P and 2 x 16 P.
Dimensions 0
References : pages 26044/2 and 26044/3
26045-EN_Ver2.11.fm/3
1/L1
– Q1
3/L2
5/L3
– F1
U1
W1
V1
M3
– KM1
1 3 5
2 4 6
2 4 6
D1
D2
E1
E2
2 4 6
1/L1
3/L2
5/L3
– KM1
12
34
56
U1
W1
V1
– Q1
11
– KM1
– KM2– KM1
12
2324
5453
– KM2
2122
A1
A2
A1
A2
– S1
– S21 0
– KM2
1314
5453
– KM1
2122
– S220
– K
M2/
1–
KM
2/5
– T1
400/24 V25 VA
– F1
21
– K
M1/
5–
KM
1/1
– KM1
– X1
– KM1
– S2
– F1 4 A
1314
1314
1112
A1
A2
– S1
– T1
400/24 V25 VA
12
21
– K
M1/
5–
KM
1/1
– KM1
– X1
– KM1
– S2
– F1 4 A
1314
1314
1112
A1
A2
– S1
– T1
400/24 V25 VA
12
21
11
– KM1
– KM2– KM1
12
2324
5453
– KM2
2122
A1
A2
A1
A2
– S1
– S21 0
– KM2
1314
5453
– KM1
2122
– S220
– K
M2/
1–
KM
2/5
– T1
400/24 V25 VA
– F1
21
1/L1
– Q1
3/L2
5/L3
U WV
– KM1 – KM2
1 3 5 1 3 5
2 4 6 2 4 6
2 4 6
1/L1
– Q1
3/L2
5/L3
U WV
– KM1 – KM2
1 3 5 1 3 5
2 4 6 2 4 6
2 4 6
D1
D2
E1
E2
Safety control and protection solutions 4
Enclosed D.O.L. starters for motor controlfor use in a machine subject to the applicationof Machinery Directive 98/37/CE
Non reversing starters
Reversing startersLJ8-K06
LJ8-K09
LJ7-K06 LJ7-K09
Schemes 0
References :pages 26044/2 and 26044/3
0259Q-EN_Ver4.1.fm/2 Schneider Electric
Selection guide Enclosed starters 2
Enclosed D.O.L. starters for AS-i bus
Applications D.O.L. starters, reversing or non-reversing
Constitution Thermal-magnetic circuit-breakerContactor or contactor pair AS-i interface module LA9-Z32811
Thermal-magnetic circuit-breakerLow consumption contactor or contactor pairElectronic control device
Operator Rotary switch
Degree of protection IP 55
Enclosure Insulated
Sensor connection With With and local/bus control
Without With With and local/bus control
Starter type Reversing LF7-PppD LF7-PppDA79 LF1-PppD LF1-PppDA78
LF1-PppDA79
Non-reversing LF8-PppD LF8-PppDA79 LF2-PppD LF2-PppDA78
LF2-PppDA79
Pages 24088/2 and 24088/3 24084/2 and 24084/3
0259Q-EN_Ver4.1.fm/3Schneider Electric
Selection guide (continued) Enclosed starters 2
Enclosed D.O.L. starters for AS-i bus
Pushbuttons
IP 65 IP 55
Metal Insulated Metal
With With and local/bus control
Without With With and local/bus control
With With and local/bus control
LF1-MPppD LF1-MPppDA79 LF1-MppD LF1-MppDA78
LF1-MppDA79
LF1-MMppD LF1-MMppDA79
LF2-MPppD LF2-MPppDA79 LF2-MppD LF2-MppDA78
LF2-MppDA79
LF2-MMppD LF2-MMppDA79
24091-EN_Ver3.1.fm/2
Presentation 1 AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. starters
These are the entry level models in our range of starters which communicate on theAS-Interface. These starters incorporate interface module LA9 Z32811 and aresubdivided according to the different power connection methods (cable gland orHarting plug-in connectors) and Local/AS-Interface remote operating modes. Theseeconomical devices provide a simple and effective solution for building decentralisedmotor starters as near as possible to the motor.
These complete, intelligent starters incorporate pre-programmed functions and afault-management function. They are available in insulated or metal enclosures tosuit different environments. When fitted with Harting plug-in connectors (variantA74), they drastically reduce setting-up times, thereby increasing the availability ofmachines.
These enclosed starters which communicate on AS-Interface are pre-assembledand ready-to-use with a minimum of cabling. They are designed for buildingdecentralised electrical installations, i.e. the starters are installed as near as possibleto the motors they are to control. The decentralisation of the starters providesobvious advantages regarding power distribution to machines not grouped together,for example: motors driving a conveyor system.
Distribution circuit circuit-breaker
Programmable controller with its inputs/outputs
Contactor + thermal overload relay
Distribution circuit circuit-breaker
Programmable controller
AS-Interface starter
Power is distributed either by prefabricated trunking or by cable.These starters incorporate all the functions necessary for the management of motors(control, protection, isolation, etc.), and comprise:
- a thermal-magnetic circuit-breaker,- a low consumption contactor (non reversing) or contactor pair (reversing),- an electronic control device or, for LF7 and LF8, an AS-Interface module,
LA9 Z32811.
Designed primarily for use with 3-phase a.c. motors, they can nevertheless be usedwith single-phase or d.c. motors. In these applications, the 3 phases of the internalcircuit-breaker should be wired in series (each phase sensing the same current) inorder to avoid tripping due to an assumed phase failure.
PresentationLF7 and LF8 starters
LF1 and LF2 starters
Decentralisation of machine starters
Traditional installation
Equipmentfloor-standingenclosure
Decentralised installation
M M M M M
AS-Interface
Distributionenclosure
Power
Characteristics :pages 24090/2 to 24090/5
References :pages 24084/2 to 24088/3
Dimensions, schemes :pages 24095/2 to 24095/9
Connections :pages 24087/2 and 24087/3
24091-EN_Ver3.1.fm/3
Description 1 AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. starters
1 Yellow LED, illuminated when motor running.2 Red LED illuminated when there is a motor fault (overload or short-circuit) or an
internal fault in the starter, or in the event of a communication fault.3 Green LED illuminated (steady light) when the AS-Interface line is powered and
flashing when information to the starter is being transmitted via the AS-Interfaceline.
4 Knock-out for cable gland (included for auxiliary supply, power extension or outputcontrol relay cabling, if required).
5 Disconnect rotary control knob.Indicates “Trip” when switch-disconnector tripped.
6 Local/AS-Interface key switch (variant A79).7 3-position, spring return to zero selector switch for reversing starter (LF2).
Function:- position 1 = forward running,- position 0 = Stop,- position 2 = reverse running (variant A79).Pushbutton for non-reversing starter (LF1) .Function: Pulsed operation (variant A79).
8 Cable gland for power supply cable.9 M12 female connector for cable connection to a sensor (supplied with protective
cap) (variants A78 and A79).10M12 male connector for connection to AS-Interface (1) and auxiliary supply, if
required.11Cable gland for motor cabling.12Reset pushbutton.13Stop pushbutton.
1 Yellow LED, illuminated when motor running.2 Red LED illuminated when there is a motor fault (overload or short-circuit) or an
internal fault in the starter, or in the event of a communication fault.3 Green LED illuminated (steady light) when the AS-Interface line is powered and
flashing when information to the starter is being transmitted via the AS-Interfaceline.
4 Knock-out for cable gland (included) for auxiliary supply cabling, if required.5 Male connector for incoming power supply to motor starter (2)6 Disconnect rotary control knob.
Indicates “Trip” when switch-disconnector tripped.7 Female connector for power supply to the next motor starter (2)8 Local/AS-Interface key switch (variant A79).9 3-position, spring return to zero selector switch for reversing starter (LF2).
Function:- position 1 = forward running,- position 0 = Stop,- position 2 = reverse running (variant A79).Pushbutton: for non-reversing starters (LF1).Function: Pulsed operation (variant A79).
10Female connector for power supply to motor (2).11Knock-out for cable gland (included) for output control relay.12M12 female connector for cable connection to a sensor (supplied with protective
cap) (variants A78 and A79).13M12 male connector for connection to AS-Interface (1) and auxiliary supply, if
required.14Stop pushbutton.15Reset pushbutton.
(1) Extension cables: please consult your Regional Sales Office.(2) Harting plug-in connector to be fitted to cable (not included, see page 24087/3).
Connection by cable gland
5
565
204
1 2 3 4
67
11 10 9 8
5652
05
1 2 3 4
11 10 9 8
6
7
1312
Connection by plug-in connectors (variant A74)
565
206
1 2 3 4
11 101213
8 6 5
7
9
565
207
1 2 3 4
11 101213
8 14 5
7
9
15
565
208
1 2 3 4
11 101213
6 7
8 9
565
209
1 2 3 4
11 101213
7
98
14 15
Characteristics :pages 24090/2 to 24090/5
References :pages 24084/2 to 24088/3
Dimensions, schemes :pages 24095/2 to 24095/9
Connections :pages 24087/2 and 24087/3
24091-EN_Ver3.1.fm/4
Functions 1 AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. starters
LF1 and LF2 starters do not require an auxiliary supply to operate the contactors,since that provided by the AS-Interface line (yellow cable) is sufficient. Again, thisreduces the cabling required.However, depending on the application, it is possible to supply the contactor coils byan external c 24 V source. Selection is made by repositioning a jumper within thestarter.
A c 24 V supply is necessary for LF7 and LF8 starters.
Prospective current consumptions are listed on page 24090/5.
The functions provided by this range of starters are:- motor control and status monitoring via AS-Interface,- D.O.L. starting (non-reversing or reversing),- overload protection of the motor,- short-circuit protection of the motor and its power supply cabling.
These starters provide the following functions:- load break switch-disconnector with padlockable control knob,- IP 55 degree of protection, double insulation.
Opening of the enclosure is mechanically inhibited whilst the starter is switched onor whilst in the off position and padlocked.
The rotary control knob has 3 positions:0: switch-disconnector opened manually,I: switch-disconnector closed,Trip: switch-disconnector tripped.
These starters provide the following functions:- pushbutton resetting of the protection device,- pushbutton stop,- IP 65 degree of protection, double insulation.
Auxiliary supply
Control-command andcontactor supply
Control-command supply
Power supply
AS-Interface
Contactor supply
c 24 V auxiliary supply
Motor command-control
Starters with rotary control knob
Starters with pushbutton control
Characteristics :pages 24090/2 to 24090/5
References :pages 24084/2 to 24088/3
Dimensions, schemes :pages 24095/2 to 24095/9
Connections :pages 24087/2 and 24087/3
1142
711
429
24091-EN_Ver3.1.fm/5
Functions (continued) 1 AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. starters
Stop and reset functions are possible from the front of the enclosure. The stopcommand is achieved by actuating the internal circuit-breaker, which provides theswitch-disconnector function.
Depending on the type of starter, stopping is controlled by either:- a rotary control knob, or- a stop pushbutton (black) (1).
In the event of an overload, resetting of the internal thermal-magnetic circuit-breakeris possible after the motor has cooled down.
Depending on the type of starter, resetting is controlled by either:- a rotary control knob, or- a reset pushbutton (blue) (1).
This starter variant is fitted with a 2-position “local/AS-Interface” switch which,depending on the position of the switch, allows the following functions:
b AS-Interface: the PLC controls the motor starter.
b Local: local Start/Stop commands override instructions from the PLC.
b 3-position, spring return to zero selector switch for reversing starters (LF2, LF8).Function:
- position 1 = forward running,- position 0 = Stop,- position 2 = reverse running.
Pushbutton for non-reversing starters (LF1, LF7). Function: Pulsed operation.
It is possible to achieve manual local start control from a pushbutton control stationconnected to AS-Interface. Please consult your Regional Sales Office.
Actuation of the pushbutton is transmitted to the programmable controller(message 1) which passes it on to the starter (message 2).
(1) Only a rotary control knob is available for starters LF7 and LF8.
Local control
Integral local/AS-Interface control (variant A79)1142
3
Control via a control station
AS-Interface
Message 1
Message 2
Power supply
Characteristics :pages 24090/2 to 24090/5
References :pages 24084/2 to 24088/3
Dimensions, schemes :pages 24095/2 to 24095/9
Connections :pages 24087/2 and 24087/3
24091-EN_Ver3.1.fm/6
Functions (continued) 1 AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. starters
Visual indication of the various operating states is provided by LEDs (3 LEDs forLF1/LF2 and 1 LED for LF7/LF8) located on the enclosure cover.
The starter features continual self-checking to ensure correct operation.
External safety functions are not processed by the starter.
Emergency stop and machine safety wiring must follow standard safety practice andbe hard-wired, using electromechanical devices in the approved way. Thesefunctions must not be handled by communication bus systems (EN 60204 § 9.2.5.4).
Protection against sudden restarting, after an accidental power supply failure, mustbe provided by a safety device separate from the starter.
The starter control (rotary knob or pushbutton) does not provide the Emergency Stopfunction if the machine is fitted with other actuators. The control operators on thestarter are therefore coloured black, in accordance with standard EN 60204 § 10.2.1.
Starters with rotary control knob may be padlocked in the ON position, since thiscontrol does not provide an Emergency Stop function.
When communication is interrupted, the starter is no longer controlled by the PLC. Inthis case, it can be configured to adopt the following fallback conditions:
- motor set to stop (applications: potentially dangerous movements),- motor set to run in direction 1 (forward) (applications: fans, pumps),- or motor continues to run as it was immediately prior to loss of control
(application: suction grippers).
The fallback configuration is set via AS-Interface.
The default configuration is with the motor set to stop.
This relay incorporates a C/O contact, which may be used to control an indicatorlamp, solenoid valve, etc. (24 V, 1 A), via AS-Interface.
Local signalling
Safety
Loss of control (LF1, LF2 only)
Output control relay (LF1, LF2 only)
AS-Interface
Characteristics :pages 24090/2 to 24090/5
References :pages 24084/2 to 24088/3
Dimensions, schemes :pages 24095/2 to 24095/9
Connections :pages 24087/2 and 24087/3
24091-EN_Ver3.1.fm/7
Functions (continued) 1 AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. starters
Two 3-wire PNP sensors (50 mA max) or 2-wire limit switches can be connecteddirectly to the starter.The information supplied by the sensor/limit switch is fed back via AS-Interface.
In addition, for LF1 and LF2 starters only, the sensor signal can be processed locallyto achieve a Reflex motor stop. This function is selected by means of micro switches.127 other selections are reserved for future applications.
There are two types of “Reflex stop” function:
b “Reflex stop” function n° 1Sensor n° 1 directly controls stopping of the motor.After a new start instruction, the motor restarts (stop instruction then startinstruction).
A Reflex stop makes it possible to achieve precise and repetitive positioning,independently of the AS-Interface and PLC cycle times.
For reversing starters, sensor n° 1 acts on both running directions.Sensor n° 2 does not affect Reflex operation.
b “Reflex stop” function n° 2Sensor n° 1 controls stopping of the motor when it is running in the forward direction.Sensor n° 2 controls stopping of the motor when it is running in reverse direction.
A new start instruction (stop instruction then start instruction) causes restarting of themotor even if a component is still detected.
Sensor n° 2 does not affect forward running. Sensor n° 1 does not affect reverserunning.
Starters with sensor connected
Reflex stop (LF1, LF2 only)
Sensor 2
AS-Interface
Sensor 1
Rev Forw
Time
Instruction from AS-Interface
Motor controlled by the starter
Information from sensor 1 = component present
Characteristics :pages 24090/2 to 24090/5
References :pages 24084/2 to 24088/3
Dimensions, schemes :pages 24095/2 to 24095/9
Connections :pages 24087/2 and 24087/3
24090-EN_Ver6.1.fm/2
Characteristics 1 AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. starters
EnvironmentStarter type LF1, LF2 LF7, LF8
Conforming to standards IEC 60204-1, EN 60204-1,IEC 60439-1, IEC 60947-4-1,EN 60947-4-1UL 508, CSA C22-2 n° 14 (1)
–
Product certifications AS-Interface pending AS-Interface N° 18601
Protective treatment Standard version “TC” “TH”
Degree of protectionconforming to IEC 60529
Starters with rotary control knob IP 55 IP 55
Starters with pushbutton control IP 65 –Ambient air temperaturearound the deviceconforming to IEC 60439-1
Storage °C - 40…+ 80 - 40…+ 85Operation °C - 5…+ 40 - 10…+ 40
Maximum operating altitude Without derating m 2000
Operating positionswithout derating
In relation to normalvertical mounting plane
Flame resistanceof equipment
Conforming to IEC 60695-2-1 °C 960
Shock resistance(1/2 sine wave, 11 ms)conforming to IEC 60068-2-27
Contactor open 10 gnContactor closed 15 gn
Vibration resistance5…150 Hzconforming to IEC 60068-2-6
Contactor open 2 gnContactor closed 4 gn
Safe separation of circuits Conforming to VDE 0106and IEC 60536
SELV (Safety Extra Low Voltage), up to 400 V
Immunity to non-dissipatingshockwave (Uimp)
Conforming to IEC 60947-1 kV 6: power2.5: AS-Interface, 24 V and sensor
6: power2: AS-Interface, 24 V and sensor
Material and colourof enclosure base
Insulated enclosures Polycarbonate impregnated with 20 % glass fibre, black throughoutMetal enclosures Sheet steel, RAL 7032 –
Material and colourof enclosure cover
Insulated enclosures Polycarbonate impregnated with 20% glass fibre, grey RAL 7032 throughout
Metal enclosures Sheet steel, RAL 7032 –
Resistance tochemical agents
Insulated enclosures Avoid allowing this material to come into contact with: strong bases (certaindetergents), aromatic hydrocarbons, alcohol, chlorine solvents, ketones.
Electromagnetic compatibilityImmunity toelectrostatic discharge
Conforming to IEC 61000-4-2EN 61000-4-2
kV 8: in open air (level 3)4: in indirect mode (level 2)
Immunity tofast transient currents
Conforming to IEC 61000-4-4EN 61000-4-4
kV 2: power, AS-Interface, 24 V and sensor(level 3)
2: AS-Interface, 24 V and oninputs/outputs
Immunity todissipated shock wave
Conforming to IEC 61000-4-5EN 61000-4-5
kV 4/2: power (level 4)
2/0.5: AS-Interface, 24 V and sensor(level 2)
2: AS-Interface, 24 V and oninputs/outputs
Immunity to conductedradio-frequency disturbance
Conforming to IEC 61000-4-6ENV 50 141
V/m 10
Immunity to radiatedradio-frequency disturbance
Conforming to IEC 61000-4-3ENV 50 140 and ENV 50 204(GSM)
V/m 10
Radio-conducted andradio-radiated rejection
ENV 55 011/CISPR11 (G1) Class B Class A
(1) Only for metal enclosures with letter U at the end of the reference.
30° 30°
90°90°
Functions :pages 24091/4 to 24091/7
References :pages 24084/2 to 24088/3
Dimensions, schemes :pages 24095/2 to 24095/9
Connections :pages 24087/2 and 24087/3
24090-EN_Ver6.1.fm/3
Characteristics (continued) 1 AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. starters
ConnectionStarter type LF1, LF7 LF2, LF8
Min. Max. Min. Max.
Power supplycabling
Screw clampterminals
Solid cable mm2 1 x 1.5 2 x 6 1 x 1.5 2 x 6Flexible cablewithout cable end
mm2 1 x 1.5 2 x 6 1 x 1.5 2 x 6
Flexible cablewith cable end
mm2 1 x 1.5 2 x 4 1 x 1.5 2 x 4
Tightening torque (1) N.m 1.7 1.7 1.7 1.7Cable gland(Pg 16)
Clamping capacity mm 10 15 10 15
Min. Max. Min. Max.Motor cabling Screw clamp
terminalsSolid cable mm2 1 x 1.5 2 x 4 1 x 1.5 1 x 4
Flexible cablewithout cable end
mm2 1 x 1.5 2 x 4 1 x 1.5 1 x 4
Flexible cablewith cable end
mm2 1 x 1.5 1 x 1.5 + 1 x 2.5 1 x 1.5 1 x 2.5
Tightening torque (1) N.m 0.8 0.8 0.8 0.8
Cable gland(Pg 16)
Clamping capacity mm 10 15 10 15
Min. Max. Min. Max.
Auxiliary 24 Vsupply and outputcontrol relaycabling
Terminal block Solid cable mm2 0.5 1.5 0.5 1.5Flexible cablewithout cable end
mm2 0.5 1.5 0.5 1.5
Flexible cablewith cable end
mm2 0.5 1.5 0.5 1.5
Tightening torque (2) N.m 0.7 0.7 0.7 0.7Cable gland(included)
Clamping capacity Pg 13 mm 8 13 8 13Pg 16 mm 10 15 10 15
Pole electrical characteristicsUtilisation category Conforming to IEC60947-2
(circuit-breaker)A
Conforming to 947-4-1(motor starter)
AC-3
Rated operational voltage (Ue) Conforming to IEC 60947 V 415
Rated insulation voltage (Ui) Conforming to IEC 60947 V 415Rated operational frequency Conforming to IEC 60947 Hz 50/60
Breaking capacity(Ics and Icu)
Conforming toIEC 60947-2
230/240 V kA > 100400/415 V kA > 100
Sensitivity to phase failure Conforming toIEC 60947-4-1 § 7-2-1-5-2
Yes
Circuit-breaker characteristics (manual operation)Mechanical durability C.O.: closing, opening C.O. 100 000
Electrical durability In category AC-3 C.O. 100 000
Service class Maximum operating rate C.O./h 25
Circuit-breaker characteristics (automatic operation)Maximum operating rate In operating cycles
per hour3600
Mechanical durability In millions ofoperating cycles
30 5
Electrical durability In category AC-3 to 8.5 A 800 000
Other characteristicsStarters with rotary control knob Circuit-breaker type
GV2 PSee our catalogue "Motor starter solutions"
Starters with pushbutton control Circuit-breaker typeGV2 ME - LF1, LF2 only
See our catalogue "Motor starter solutions"
Non-reversing starters ContactorLP4 K09015BW3
See our catalogue "Motor starter solutions"
Reversing starters Reversing contactorLP5 K09015BW3
See our catalogue "Motor starter solutions"
(1) Philips n° 2 or flat screwdriver Ø 5.5.(2) Flat screwdriver Ø 3.5.
Functions :pages 24091/4 to 24091/7
References :pages 24084/2 to 24088/3
Dimensions, schemes :pages 24095/2 to 24095/9
Connections :pages 24087/2 and 24087/3
24090-EN_Ver6.1.fm/4
Characteristics (continued) 1 AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. starters
Sensor inputsStarter type LF1, LF2 (A78 and A79) LF7, LF8 (A78)
Connection M12 M12
Nominal input values Voltage V c 24 c 24Maximum currentavailable per sensor
mA 50 7
Sensor supply (including ripple) V 19…30 –
Input value limits At state 1 Voltage V c >12.6 –Current mA > 4.9 –
At state 0 Voltage V c <5 –
Current mA < 2.1 –Input impedance kΩ > 2 –
Filtering time Typical ms 7 –Maximum ms 9.8 –
Maximum number of sensors 2 2
Proximity sensor compatibility 2-wire/3-wire 2-wire
Isolation with respect to the AS-Interface line None –
Input type Resistive for PNP type sensor –
Output control relay (for starters LF1 and LF2 with variants A78 and A79)Operating voltage limit a.c. supply V 24
d.c. supply V 24Thermal current at 40 °C (Ith) A 5
Service lifeon an a 24 V load
ResistiveloadAC-12
Millions of operating cycles 0.1 (1) in 5 A current,1 (2) in 1 A current.
InductiveloadAC-14
Millions of operating cycles 0.5 (2) in 1 A current,1 (2) in 0.5 A current,5 (3) in 0.25 A current.
Service lifeon a c 24 V load
ResistiveloadDC-12
Millions of operating cycles 0.1 (1) in 5 A current,0.2 (1) in 2 A current.
ResistiveloadDC-3
Millions of operating cycles 0.5 (2) in 1 A current,> 1 (3) in 0.25 A current.
Response time Latching ms < 10Unlatching ms < 10
Contact type C/O
Built-in protection Against overloadsand short-circuits
None, a quick-blow fuse must be fitted
Against a.c. or d.c.inductive overloads
Protected against overvoltages generated by switching the coils of preactuators
Isolation rms voltage between outputand earth or between outputand internal logic
V 1500, 50/60 Hz for 60 s
Insulation resistance betweenoutput terminals and AS-Interface
mΩ > 1000
(1) 0.2 of an operation (C/O) per second.(2) 0.5 of an operation (C/O) per second.(3) 1 operation (C/O) per second.
Functions :pages 24091/4 to 24091/7
References :pages 24084/2 to 24088/3
Dimensions, schemes :pages 24095/2 to 24095/9
Connections :pages 24087/2 and 24087/3
24090-EN_Ver6.1.fm/5
Characteristics (continued) 1 AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. starters
ConsumptionStarter type Product configured
for supply from theAS-Interface line
Product configured forsupply from anauxiliary c 24 V supply
LF1 LF2 LF1 LF2 LF7 LF8Current consumption From the
AS-Interface lineDe-energised 80 mA 90 mA 80 mA 90 mA 8 mA 8 mA
Inrush 190 mA 200 mA 80 mA 90 mA – –Sealed 110 mA 120 mA 80 mA 90 mA 12 mA 12 mA
With sensor Sensor consumption (50 mA max) + 15 mA (signal = 1)Relay 25 mA
From the auxiliaryc 24 V supply
De-energised – – 0 0 0 0Inrush – – 110 mA 110 mA 750 mA 750 mA
Energised – – 30 mA 30 mA 750 mA 750 mA
Data exchange characteristicsAS-Interface profile 7.D (3) 7F
Data bits (commands) Bit value = 0 = 1 For commands, please refer to the LF7 andLF8 starter schemes on page 24095/6.
Command D0 (O) Stop - forward running Start - forward running
Command D1 (O) Stop - reverse running Start - reverse running(2)
Command D2 (O) Deactivation ofcontrol relay
Activation ofcontrol relay
Command D3 (O) Not Used Not Used
Data bits (status) Bit value = 0 = 1 For states, please refer to the LF7 and LF8starter schemes on page 24095/6.
Status D0 (I) Not ready or fault Ready
Status D1 (I) Stopped Running
Status D2 (I) Sensor 1 signal absent(1)
Sensor 1 signal present(1)
Status D3 (I) Sensor 2 signal absent(1)
Sensor 2 signal present(1)
Parameter bits Bit value = 0 = 1 (default value) –
Parameter P0 Maintainoperational state
Assumefallback condition
Not used
Parameter P1 Fallback condition -Start
Fallback condition -Stop
Not used
Parameter P2 Not used Not used Not used
Parameter P3 Reflex functioninhibited
Reflex functionenabled
Not used
(1) Only applicable to starters with sensors (variants A78 and A79).(2) Only on LF2 or LF8.(3) Please consult the user’s guide supplied with the product.
Functions :pages 24091/4 to 24091/7
References :pages 24084/2 to 24088/3
Dimensions, schemes :pages 24095/2 to 24095/9
Connections :pages 24087/2 and 24087/3
24084-EN_Ver10.1.fm/2
Characteristics,references 1
AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. startersModels LF1 P and LF2 P
CharacteristicsConforming to standards IEC 60204-1, 60439-1, 60947-4-1, EN 60204-1, 60947-4-1
UL 508, CSA C22-2 n° 14 (1)
Degree of protection Conforming to IEC 60529 IP 55Ambient air temperature Operation - 5 to + 40 °COperating positions Same as for the contactors
Material LFp P: polycarbonate (2). LFp MP: sheet steel
Starters in insulated enclosuresStandard power ratings of 3-phase motors50/60 Hz in category AC-3
Circuit-breakeradjustment rangeof thermal trips
StarterReference Weight
220/230 V 400/415 VkW kW A kg
Non-reversing starters with rotary control knob, with blue handle on black background (3)– – Without LF1 P00D (4) 1.020
– 0.06 0.16…0.25 LF1 P02D 1.3000.06 0.09 0.25…0.40 LF1 P03D 1.300
––
0.120.18
0.40…0.63 LF1 P04D 1.300
0.090.12
0.25–
0.63…1 LF1 P05D 1.300
0.180.25
0.370.55
1…1.6 LF1 P06D 1.350
0.37 0.75 1.6…2.5 LF1 P07D 1.3500.550.75
1.11.5
2.5…4 LF1 P08D 1.350
1.1 2.2 4…6.3 LF1 P10D 1.3501.5–
34
6…10 LF1 P14D 1.350
2.23
5.5–
9…14 LF1 P16D 1.350
Reversing starters with rotary control knob, with blue handle on black background (3)– – Without LF2 P00D (4) 1.020
– 0.06 0.16…0.25 LF2 P02D 1.5500.06 0.09 0.25…0.40 LF2 P03D 1.550
––
0.120.18
0.40…0.63 LF2 P04D 1.550
0.090.12
0.25–
0.63…1 LF2 P05D 1.550
0.180.25
0.370.55
1…1.6 LF2 P06D 1.600
0.37 0.75 1.6…2.5 LF2 P07D 1.6000.550.75
1.11.5
2.5…4 LF2 P08D 1.600
1.1 2.2 4…6.3 LF2 P10D 1.6001.5–
34
6…10 LF2 P14D 1.600
2.23
5.5–
9…14 LF2 P16D 1.600
Starters in metal enclosuresAdd the letter M after LF1 or LF2 in the references selected above. Example: LF1 P02D becomes LF1 MP02D.To order a starter that conforms to standards UL 508 and CSA C22-2 n° 14, add a letter M after LF1 or LF2 and the letter Uat the end of the references selected above. Example: LF1 P02D becomes LF1 MP02DU.Metal enclosures are fitted, as standard, with connections for 2 sensors.
Variants (pre-assembled)Description For mounting on Suffix to be added to the
starter reference (5)
With HARTING connectors (6) Insulated or metal enclosure A74With connections for 2 sensors Insulated enclosure A78With connections for 2 sensorsand local/AS-Interface control
Insulated enclosure A79
With local/AS-Interface control Metal enclosure A79(1) Only for metal enclosures with letter U at the end of the reference.(2) Avoid allowing the material to come into contact with strong bases (detergents, chlorine solvents, ketones, alcohol, aromatic
hydrocarbons).(3) On metal enclosures only, to order an Emergency Stop rotary control knob with red handle on yellow background, add the
letter R to the end of the reference. Example: LF1 MP02DR.(4) Supplied without circuit-breaker GV2 P.(5) Example: LF1 P02DA79A74.(6) Connectors to be fitted to cables (to be ordered separately, see page 24087/3).
LF1 PppD
1142
7
LF1 PppDA78
1142
7
LF2 PppDA79A74
1143
2
LF2 MPppDA74A79
1143
1
Dimensions :pages 24095/2 to 24095/5
Schemes :pages 24095/7 and 24095/9
24084-EN_Ver10.1.fm/3
Characteristics,references (continued) 1
AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. startersModels LF1 M and LF2 M
CharacteristicsConforming to standards IEC 60204-1, 60439-1, 60947-4-1, EN 60204-1, 60947-4-1
UL 508, CSA C22-2 n° 14 (1)
Degree of protectionConforming to IEC 60529
Insulated enclosure IP 65Metal enclosure IP 55
Ambient air temperature Operation - 5 to + 40 °C
Operating positions Same as for the contactorsMaterial LFp M: polycarbonate (2). LFp MM: sheet steel
Starters in insulated enclosuresStandard power ratings of 3-phase motors50/60 Hz in category AC-3
Circuit-breakerAdjustment rangeof thermal trips
StarterReference Weight
220/230 V 400/415 VkW kW A kg
Non-reversing starters with pushbutton control– – Without LF1 M00D (3) 1.000– 0.06 0.16…0.25 LF1 M02D 1.250
0.06 0.09 0.25…0.40 LF1 M03D 1.250––
0.120.18
0.40…0.63 LF1 M04D 1.250
0.090.12
0.25–
0.63…1 LF1 M05D 1.250
0.180.25
0.370.55
1…1.6 LF1 M06D 1.300
0.37 0.75 1.6…2.5 LF1 M07D 1.300
0.550.75
1.11.5
2.5…4 LF1 M08D 1.300
1.1 2.2 4…6.3 LF1 M10D 1.300
1.5–
34
6…10 LF1 M14D 1.300
2.23
5.5–
9…14 LF1 M16D 1.300
Reversing starters with pushbutton control– – Without LF2 M00D (3) 1.000– 0.06 0.16…0.25 LF2 M02D 1.500
0.06 0.09 0.25…0.40 LF2 M03D 1.500––
0.120.18
0.40…0.63 LF2 M04D 1.500
0.090.12
0.25–
0.63…1 LF2 M05D 1.500
0.180.25
0.370.55
1…1.6 LF2 M06D 1.550
0.37 0.75 1.6…2.5 LF2 M07D 1.550
0.550.75
1.11.5
2.5…4 LF2 M08D 1.550
1.1 2.2 4…6.3 LF2 M10D 1.550
1.5–
34
6…10 LF2 M14D 1.550
2.23
5.5–
9…14 LF2 M16D 1.550
Starters in metal enclosuresAdd the letter M after LF1 or LF2 in the references selected above. Example: LF1 M02D becomes LF1 MM02D.To order a starter that conforms to standards UL 508 and CSA C22-2 n° 14, add a letter M after LF1 or LF2 and the letter Uat the end of the references selected above. Example: LF1 M02D becomes LF1 MM02DU.Metal enclosures are fitted, as standard, with connections for 2 sensors.
Variants (pre-assembled)Description For mounting on Suffix to be added to the
starter reference (4)With HARTING connectors (5) Insulated or metal enclosure A74With connections for 2 sensors Insulated enclosure A78With connections for 2 sensors andlocal/AS-Interface control
Insulated enclosure A79
With local/AS-Interface control Metal enclosure A79(1) Only for metal enclosures with letter U at the end of the reference.(2) Avoid allowing the material to come into contact with strong bases (detergents, chlorine solvents, ketones, alcohol, aromatic
hydrocarbons).(3) Supplied without GV2 ME motor circuit-breaker.(4) Example: LF1 M02DA79A74.(5) Connectors to be fitted to cables (to be ordered separately, see page 24087/3).
LF1 MppD
1142
9
LF1 MppDA78
1142
6
LF1 MppDA79
1142
5
LF2 MMppDA79A74
1143
2
Dimensions :pages 24095/2 to 24095/5
Schemes :pages 24095/7 and 24095/9
24088-EN_Ver7.1.fm/2
Characteristics,references (continued) 1
AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. startersModel LF7 P
CharacteristicsConforming to standards –
Degree of protection Conforming to IEC 60529 IP 55
Ambient air temperature Operation - 10 to + 40 °C
Operating positions Same as for the contactors
Material Polycarbonate (1)
Starters in insulated enclosuresNon-reversing starters with rotary control knob, with red handle on yellow backgroundStandard power ratings of 3-phase motors50/60 Hz in category AC-3
Circuit-breakerAdjustment rangeof thermal trips
StarterReference Weight
220/230 V 400/415 VkW kW A kg
– – Without LF7 P00D (2) 1.020
– 0.06 0.16…0.25 LF7 P02D 1.300
0.06 0.09 0.25…0.40 LF7 P03D 1.300
––
0.120.18
0.40…0.63 LF7 P04D 1.300
0.090.12
0.25–
0.63…1 LF7 P05D 1.300
0.180.25
0.370.55
1…1.6 LF7 P06D 1.350
0.37 0.75 1.6…2.5 LF7 P07D 1.350
0.550.75
1.11.5
2.5…4 LF7 P08D 1.350
1.1 2.2 4…6.3 LF7 P10D 1.350
1.5–
34
6…10 LF7 P14D 1.350
2.23
5.5–
9…14 LF7 P16D 1.350
Variants (pre-assembled)Description Suffix to be added to the
starter reference (3)With HARTING connectors (4) A74
With local/AS-Interface control (5) A79
(1) Avoid allowing the material to come into contact with strong bases (detergents, chlorine solvents, ketones, alcohol, aromatichydrocarbons).
(2) Supplied without GV2 P motor circuit-breaker.(3) Example: LF1 P02DA79A74.(4) Connectors to be fitted to cables (to be ordered separately, see page 24087/3).(5) LF7 enclosures are fitted, as standard, with connections for 2 sensors (2-wire only).
1163
711
633
Dimensions :pages 24095/2 and 24095/3
Schemes :pages 24095/6 to 24095/9
LF7 PppDA74
LF7 PppD
24088-EN_Ver7.1.fm/3
Characteristics,references (continued) 1
AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. startersModel LF8 P
CharacteristicsConforming to standards –
Degree of protection Conforming to IEC 60529 IP 55
Ambient air temperature Operation - 10 to + 40 °C
Operating positions Same as for the contactors
Material Polycarbonate (1)
Starters in insulated enclosuresReversing starters with rotary control knob, with red handle on yellow backgroundStandard power ratings of 3-phase motors50/60 Hz in category AC-3
Circuit-breakerAdjustment rangeof thermal trips
StarterReference Weight
220/230 V 400/415 VkW kW A kg
– – Without LF8 P00D (2) 1.020
– 0.06 0.16…0.25 LF8 P02D 1.550
0.06 0.09 0.25…0.40 LF8 P03D 1.550
––
0.120.18
0.40…0.63 LF8 P04D 1.550
0.090.12
0.25–
0.63…1 LF8 P05D 1.550
0.180.25
0.370.55
1…1.6 LF8 P06D 1.600
0.37 0.75 1.6…2.5 LF8 P07D 1.600
0.550.75
1.11.5
2.5…4 LF8 P08D 1.600
1.1 2.2 4…6.3 LF8 P10D 1.600
1.5–
34
6…10 LF8 P14D 1.600
2.23
5.5–
9…14 LF8 P16D 1.600
Variants (pre-assembled)Description Suffix to be added to the
starter reference (3)
With HARTING connectors (4) A74
With connection for 2 sensors (2-wire only) A78
With local/AS-Interface control A79
(1) Avoid allowing the material to come into contact with strong bases (detergents, chlorine solvents, ketones, alcohol, aromatichydrocarbons).
(2) Supplied without GV2 P motor circuit-breaker.(3) Example: LF8 P02DA79A74.(4) Connectors to be fitted to cables (to be ordered separately, see page 24087/3).
LF8 PppDA78
1163
7
LF2 PppDA78A74
1163
3
Dimensions :pages 24095/2 and 24095/3
Schemes :pages 24095/6 to 24095/9
24089-EN_Ver5.1.fm/2
References (continued) 1 AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. starters
Insulated enclosures LF1, LF2, LF7, LF8Power extension (daisy-chaining) Terminal
Metal enclosures LF1, LF2
LA9 LFF
LA9 LFC
LA9 LFM
LA9 LFF
LA9 LFT
LA9 LFM
LA9 LFFM40
LA9 LFMM
LA9 LFM
24089-EN_Ver5.1.fm/3
References (continued) 1 AS-Interface cabling system 1
Dedicated componentsEnclosed D.O.L. starters
Accessories for insulated enclosures with variant A74Presentation
In order to reduce setting-up times and to simplify maintenance, variant A74 LFstarters are fitted with Harting plug-in connectors. These starters are designed toallow 2 types of connection topology.
Connectionusing tap links
This configuration avoids having to switch off the powersupply when replacing or adding one or more starters.Although machine availability is increased, a largernumber of power connections is required: 4 per starter.
Connectionusing powerextension(daisy-chaining)
The number of power connections per starter is halved, butcontinuity of service is no longer assured if any of the“upstream” starters are disconnected or removed. Withthis type of installation, special precautions must be takenbecause removal of a starter at the head of the powersupply line de-energises all the remaining starters on thatline. For safety reasons therefore, starters must not beremoved under load (prohibited by standard EN60204above 3kW/400V).
The 2 connection kits and accessories shown below have been designed to facilitate setting upof power extension configurations by the user.
Connection kit (depending on enclosure application)Enclosureapplication
Capacity Kit contents Formounting on
Reference Weight
mm2 kgPowerextension
3-pole1.5 or 2.5
1 female connector2 male connectors andcorresponding powersockets (1)
IP 55enclosuresLF1, LF2, LF7,LF8
LA9 LFC 0.150
Terminal 3-pole1.5 or 2.5
1 female connector1 male connector,1 blanking plug andcorresponding powersockets (1)
IP 55enclosuresLF1, LF2, LF7,LF8
LA9 LFT 0.110
Crimping contactsType Capacity
mm2Sold inlots of
Unitreference
Weightkg
Male 1.5 100 LA9 LFM15 0.120
2.5 100 LA9 LFM25 0.120
Female 1.5 100 LA9 LFF15 0.160
2.5 100 LA9 LFF25 0.150
Accessories for metal enclosures with variant A74Connection kitForconnector
Kitcontents
Formounting on
Reference Weight
kgInput 1 metal cover
2 size 16 cable glands1 blanking plug1 female power socket (3P + earth)4 female crimping contacts (2)
MetalenclosuresLF1, LF2
LA9 LFFM40 0.260
Outputto motor
1 metal cover1 size 16 cable gland1 female power socket(3P + earth) (1)
MetalenclosuresLF1, LF2
LA9 LFMM 0.060
Crimping contactsType Capacity Thermal
currentVoltage Sold in
lots ofUnitreference
Weight
mm2 A V kgMale 1.5 10 400 100 LA9 LFM15 0.120
2.5 10 400 100 LA9 LFM25 0.120
(1) Crimping contacts to be ordered separately.(2) For flexible cable, 4 mm2 maximum, Ith: 16 A, Us: 400 V.
LF LF
LF LF
24095-EN_Ver4.1.fm/2
Dimensions AS-Interface cabling system 3
Dedicated componentsD.O.L. starters in insulated enclosureModels LF1 P, LF2 P, LF7 P and LF8 P
Non-reversing and reversing starters with rotary control knobWith cable glands With HARTING plug-in connectors (A74)
LFp PppD LFp PppDA74
With cable glandsIncorporating sensor variant (A78)
With HARTING plug-in connectors (A74)Incorporating sensor variant (A78)
LFp PppDA78 LFp PppDA78A74
With cable glandsIncorporating sensor and local/AS-Interface control variant (A79)
With HARTING plug-in connectors (A74)Incorporating sensor and local/AS-Interface control variant (A79)
LFp PppDA79 LFp PppDA79A74
Knock-outs for cable glandFrom above 2 x Pg16 and 2 x Pg13
From below 1 x Pg16(1) M12 male connector for connection to AS-Interface(2) M12 female connector for connection to sensor.
175
120
150
165
30
84
(1)
4x5,3
175 175
120
150
165
18
84
(1)
4x5,3
175 47
175
120
150
165
30
84
(1) (2)
4x5,3
175
120
150
165
18
84
(1) (2)
4x5,3
175175 47
175
120
150
165
30
84
(1) (2)
4x5,3
175
120
150
165
18
84
(1) (2)
4x5,3
175175 47
References :pages 24084/2 to 24088/3
Schemes :pages 24095/6 to 24095/9
24095-EN_Ver4.1.fm/3
Dimensions (continued) AS-Interface cabling system 3
Dedicated componentsD.O.L. starters in insulated enclosureModels LF1 M and LF2 M
Non-reversing and reversing starters with pushbutton controlWith cable glands With HARTING plug-in connectors (A74)
LFp MppD LFp MppDA74
With cable glandsIncorporating sensor variant (A78)
With HARTING plug-in connectors (A74)Incorporating sensor variant (A78)
LFp MppDA78 LFp MppDA78A74
With cable glandsIncorporating sensor and local/AS-Interface control variant (A79)
With HARTING plug-in connectors (A74)Incorporating sensor and local/AS-Interface control variant (A79)
LFp MppDA79 LFp MppDA79A74
Knock-outs for cable glandFrom above 2 x Pg16 and 2 x Pg13
From below 1 x Pg16(1) M12 male connector for connection to AS-Interface(2) M12 female connector for connection to sensor.
120
150
165
30
84
(1)
4x5,3
175140 140
120
150
165
18
84
(1)
4x5,3
175 47
120
150
165
30
84
(1) (2)
4x5,3
175140 140
120
150
165
18
84
(1) (2)
4x5,3
175 47
120
150
165
30
84
(1) (2)
4x5,3
175165 165
120
150
165
18
84
(1) (2)
4x5,3
175 47
References :pages 24084/2 to 24088/3
Schemes :pages 24095/6 to 24095/9
24095-EN_Ver4.1.fm/4
Dimensions (continued) AS-Interface cabling system 3
Dedicated componentsD.O.L. starters in metal enclosureModels LF1 MP and LF2 MP
Non-reversing and reversing starters with rotary control knobWith cable glands With HARTING plug-in connectors (A74)
LFp MPppD LFp MPppDA74
With cable glandsIncorporating sensor variant (A78)
With HARTING plug-in connectors (A74)Incorporating sensor variant (A78)
LFp MPppDA78 LFp MPppDA78A74
With cable glandsIncorporating sensor and local/AS-Interface control variant (A79)
With HARTING plug-in connectors (A74)Incorporating sensor and local/AS-Interface control variant (A79)
LFp MPppDA79 LFp MPppDA79A74
Knock-outs for cablegland
Standard enclosure Enclosure with variantA74
From above 3 x Pg16 1 x Pg16
From below 2 x Pg16 1 x Pg16(1) M12 male connector for connection to AS-Interface(2) M12 female connector for connection to sensor.
8,5Ø7
Ø13
179
125
199
230
245
175
(1)
219 179
125
(1)
199
230
245
175
219 60
8,5Ø7
Ø13
8,5Ø7
Ø13 (1) (2)
179
125
199
230
245
175
219 179125
(1) (2)
199
230
245
175
219 60
8,5Ø7
Ø13
8,5Ø7
Ø13 (1) (2)
199
230
245
175
219179
125
179
125
(1) (2)
199
8,5
230
245
175Ø7
Ø13
219 60
References :pages 24084/2 and 24084/3
Schemes :pages 24095/7 to 24095/9
24095-EN_Ver4.1.fm/5
Dimensions (continued) AS-Interface cabling system 3
Dedicated componentsD.O.L. starters in metal enclosureModels LF1 MM and LF2 MM
Non-reversing and reversing starters with pushbutton controlWith cable glands With HARTING plug-in connectors (A74)
LFp MMppD LFp MMppDA74
With cable glandsIncorporating sensor variant (A78)
With HARTING plug-in connectors (A74)Incorporating sensor variant (A78)
LFp MMppDA78 LFp MMppDA78A74
With cable glandsIncorporating sensor and local/AS-Interface control variant (A79)
With HARTING plug-in connectors (A74)Incorporating sensor and local/AS-Interface control variant (A79)
LFp MMppDA79 LFp MMppDA79A74
Knock-outs for cablegland
Standard enclosure Enclosure with variantA74
From above 3 x Pg16 1 x Pg16
From below 2 x Pg16 1 x Pg16(1) M12 male connector for connection to AS-Interface(2) M12 female connector for connection to sensor.
8,5Ø7
Ø13
145
125
199
230
245
175
(1)
219
8,5Ø7
Ø13
145
125
(1)
199
230
245
175
219 60
145
125
(1) (2)
199
230
245
175
219
8,5Ø7
Ø13
145
125
(1) (2)
199
230
245
175
219 60
8,5Ø7
Ø13
8,5Ø7
Ø13 (1) (2)
169125
199
230
245
175219 169
125
(1) (2)
199
230
245
175
219 60
8,5Ø7
Ø13
References :pages 24084/2 and 24084/3
Schemes :pages 24095/7 to 24095/9
24095-EN_Ver4.1.fm/6
Schemes AS-Interface cabling system 3
Dedicated componentsEnclosed D.O.L. startersModels LF7 and LF8
Non-reversing starters LF7LF7
LF7 with variant A79
Reversing starters LF8LF8 without variant and LF8 with variant A79
LF8 with variant A78
1/L1
– Q
3/L2
5/L3
– KM
U WV
2/T
1
6/T
3
4/T
2
M
LA9 Z32811 (7F)
IN1
– X
3, 1
IN2
– X
3, 2
IN3
– X
3, 3
IN4
– X
3, 4
IN +
– X
3, 5
M –
– X
3, 6
OU
T 1
– X
3, 7
2122
– KM
1 4
2 35
– KM
A1
A2
2423
– Q
1413
– Q
LA9 Z32811 (7F)IN
1–
X3,
1
IN2
– X
3, 2
IN3
– X
3, 3
IN4
– X
3, 4
IN +
– X
3, 5
M –
– X
3, 6
OU
T 1
– X
3, 7
2122
– KM
1 4
2 3
24 V
24 V
0 V
5
– KM
A1
A2
2423
– Q
1413
– Q
+
–
AS-i +
AS-i –
+
–
24 V
0 V 0 1
Local line
1/L1
– Q
3/L2
5/L3
– KM1 – KM2
U WV
2/T
1
6/T
3
4/T
2
M
LA9 Z32811 (7F)
IN1
– X
3, 1
IN2
– X
3, 2
IN3
– X
3, 3
IN4
– X
3, 4
IN +
– X
3, 5
M –
– X
3, 6
OU
T 2
– X
3, 8
OU
T 1
– X
3, 7
2122
– KM1
2122
– KM2
24 V
24 V0 V
1413
– Q
2423
61 61
62 62
– Q
+
–
AS-i +
AS-i –
+
–
– KM1
– KM1
– KM2
– KM2
A1 A1
A2A2
24 V
0 V
II 0 I
LF8 with variant A79
Local line
– KM1
– KM1
– KM2
– KM2
A1 A1
A2A2
2423 61 61
62 62
– Q
LA9 Z32811 (7F)
IN1
– X
3, 1
IN2
– X
3, 2
IN3
– X
3, 3
IN4
– X
3, 4
IN +
– X
3, 5
M –
– X
3, 6
OU
T 2
– X
3, 8
OU
T 1
– X
3, 7
2122
– KM2
14
2 35
1413
– Q
2122
– KM1
References :pages 24088/2 and 24088/3
Dimensions :pages 24095/2 and 24095/3
24095-EN_Ver4.1.fm/7
Schemes (continued) AS-Interface cabling system 3
Dedicated componentsEnclosed D.O.L. startersModels LF1 and LF2
Non-reversing starters LF1
Reversing starters LF2
1/L1
– Q
3/L2
5/L3
– KM
U WV
2/T
1
6/T
3
4/T
2
M
– K3
M12 AS-iAS-i –
AS-i +
– KM
AS
-i –
AS
-i +
24 V
AS
-i
0 V
AS
-i
NO COM NC
AS-i
AS-i
GV2
GV2 GV2 KM
I
24 V ext.
0 V ext.
GV2 open
GV2 tripped
K1 auxiliary
Local/AS-I
Signal sensor 1
Signal sensor 2
Economyresistor
Forwardrunning
Output control relay
24 V ext.
Local/line
M12 sensor
Insulated enclosure with variant A78
+ Insulated enclosure with variant A79 or metal enclosure with variant A79
1/L1
3/L2
5/L3
– KM1 – KM2
U WV
2/T
1
6/T
3
4/T
2
M
21 0
– KM1
– K3
M12 AS-iAS-i –AS-i +
– KM2
AS
-i –
AS
-i +
24 V
AS
-i
0 V
AS
-i
KM1
KM2
NO COM NC
AS-i
AS-i
GV2
GV2 GV2 KM1 KM2
24 V ext.
0 V ext.
GV2 open
GV2 tripped
Local/line
Signal sensor 1
Signal sensor 2
Economyresistor
Forward running
Output control relay
24 V ext.
Local/line
M12 sensor
Insulated enclosure with variant A78
+ Insulated enclosure with variant A79 or metal enclosure with variant A79
Reverse running
References :pages 24084/2 and 24084/3
Dimensions :pages 24095/2 to 24095/5
24095-EN_Ver4.1.fm/8
Recommendedapplication schemes
AS-Interface cabling system 3
Dedicated componentsEnclosed D.O.L. startersModels LF1, LF2, LF7 and LF8
Non-reversing and reversing starters without sensor and without an auxiliary supply
Non-reversing and reversing starters with 2 sensors, an auxiliary supply and a control relay1L
1
3L2
5L3
2T1
4T2
6T3
1L1
3L2
5L3
2T1
4T2
6T3
U WV
MU WV
M
AS-Interface line
1L1
3L2
5L3
J2 N
C
J2 C
OM
J2 N
O
2T1
4T2
6T3
J5Ð
J5+
1L1
3L2
5L3
2T1
4T2
6T3
U WV
M
U WV
M
24 V
AS-Interface line
References :pages 24084/2 to 24088/3
Dimensions :pages 24095/2 to 24095/5
24095-EN_Ver4.1.fm/9
Recommendedapplication schemes(continued)
AS-Interface cabling system 3
Dedicated componentsEnclosed D.O.L. startersModels LF1 and LF2
Connections on enclosures (LF1, LF2 only)M12 male connector for AS-Interface and c 24 V auxiliary supply
Sensor M12 female connector(for starters LF1 and LF2, only applicable to starters with sensor variants A78 and A79)
Limit switch 2-wire PNP type sensor 3-wire PNP type sensor
34
21
24 V AS-i
AS-i + 0 V
–
43
12
5 Sensor 1
Sensor 2
43
12
–
–
++
5Sensor 1
Sensor 2
–
–
++
43
12
5Sensor 1
Sensor 2
References :pages 24084/2 to 24088/3
Dimensions :pages 24095/2 to 24095/5
24087-EN_Ver8.1.fm/2
Connections AS-Interface cabling system 3
Dedicated componentsEnclosed D.O.L. starters
Starters in enclosures with cable glands
1 Junction box
2 Incoming power
3 Power extension
4 XZ LC1220C1: splitter block
5 XZ CR1511040Ap: extension
6 XZ CB1pp02: flat cable (black) for auxiliary supply
7 XZ CG01403D: tap link for two cables
8 XZ CB1pp01: flat cable (yellow) for AS-Interface
9 XZ CG01205D: tap link for one cable
M
1
2
5
3
7
8
8
9 6
4
Functions :pages 24091/4 to 24091/7
Characteristics :pages 24090/2 to 24090/5
References :pages 24084/3 and 24088/2
Dimensions, schemes :pages 24095/2 to 24095/9
24087-EN_Ver8.1.fm/3
Connections (continued) AS-Interface cabling system 3
Dedicated componentsEnclosed D.O.L. starters
Starters in insulated enclosures with HARTING type plug-in power connectors
1 Incoming power2 Power extension3 Control relay (example: illuminated indicator bank)4 XZ LC1220C1: splitter block5 XZ CR1511040Ap: extension6 XZ CB1pp02: flat cable (black) for auxiliary supply7 XZ CG01403D: tap link for two cables8 XZ CB1pp01: flat cable (yellow) for AS-Interface9 XZ CG01205D: tap link for one cable
Configuration of HARTING connectors to be fitted on cables(to be ordered separately)
Number and HARTING referencefor incoming powerfemale connector
for power extensionand motor connectionmale connectors
Straight cover 1 x 09-20-003-0420 2 x 09-20-003-0420
Male insert6-way, 400 V
– 2 x 09-12-005-3101
Female insert6-way, 400 V
1 x 09-12-005-3001 –
Male contacts2.5 mm2
– 8 x 09-33-000-6102
Female contacts2.5 mm2
3 x 09-33-000-6202 –
Plug for the last socket – 1 x 09-20-003-5408
Starters in metal enclosures with HARTING type plug-in power connectors
1 Incoming power2 Control relay (example: illuminated indicator bank)3 XZ LC122C1: splitter block4 XZ CR1511040Ap: extension5 XZ CB1pp02p: flat cable (black) for auxiliary supply6 XZ CG1403D: tap link for two cables7 XZ CB1pp01p: flat cable (yellow) for AS-Interface8 XZ CG01205D: tap link for one cable
Configuration of HARTING connectors to be fitted on cables(to be ordered separately)
Number and HARTING referencefor incoming powerfemale connector
for power extensionand motor connectionmale connectors
Straight cover 1 x 09-30-006-442 (1)1 x 09-30-006-443 (2)
2 x 09-20-003-1440
Male insert6-way, 400 V
– 2 x 09-12-005-3101
Female insert6-way, 400 V
1 x 09-33-006-2702 –
Male contacts2.5 mm2
– 5 x 09-33-000-6102
Female contacts2.5 mm2
3 x 09-33-000-6207 –
(1) PG21.(2) PG29.
M
3
4
1
2
5
7
88
9 6
M
2
3
1
4
6
77
8 5
Functions :pages 24091/4 to 24091/7
Characteristics :pages 24090/2 to 24090/5
References :pages 24084/2 to 24088/3
Dimensions, schemes :pages 24095/2 to 24095/9
24584-EN_Ver4.1.fm/2
Presentation 1 AS-Interface cabling system 1
Dedicated componentsLA9 Z, AS-Interface V1For D.O.L. starters
AS-interface modules LA9 Z32810 and LA9 Z32811 allow motor starters to bemonitored and controlled by AS-Interface. These products are in addition to the“AS-Interface enclosed starter” range, LF1 and LF2, LF7 and LF8.
The module sizes offered are: 2 inputs/1 output or 4 inputs/2 outputs.
These products can be mounted in two ways:
b on 5 rail,b on LA9 Zppp adapters for use with busbar systems.
Inputs/outputs are connected to a built-in, flexible terminal type connector, soreducing installation time.The AS-Interface line is connected to the module by the yellow connector.The external c 24 V supply to the module outputs is connected to the blackconnector. With this supply method, it is possible to make the output states subjectto external safety conditions (Emergency stop, safety overtravel, etc.).
Presentation
AS-I
PWR
AS-I
PWR
5651
88
5651
89
Characteristics :page 24584/4
References :page 24584/5
Dimensions, schemes :pages 24584/6 and 24584/7
24584-EN_Ver4.1.fm/3
Presentation (continued) 1 AS-Interface cabling system 1
Dedicated componentsLA9 Z, AS-Interface V1For D.O.L. starters
The various module sizes allow control of:
- non-reversing starters,- reversing starters,- 2-speed starters for motors with separate windings.
The outputs, supplied by the separate auxiliary voltage, can simultaneously switch acurrent of 0.5 A at c 24 V and can therefore switch the following contactors:
- LP1, LP4 K06 ... K12,- LC1 D09 to D32.
AS-Interface module
1 AS-Interface green/red LED indicator:- red: no communication with the Master. The outputs are switched off,- green: communication OK, outputs OK,- red/yellow flashing: module has no address (assign an address between 1 and 31),- off: no power supply to AS-Interface.
2 Green PWR LED:- LED on: auxiliary power supply ON,- LED off: auxiliary power supply OFF.
Fields of application
Composition
AS-I
PWR
1
2
5651
90
Characteristics :page 24584/4
References :page 24584/5
Dimensions, schemes :pages 24584/6 and 24584/7
24584-EN_Ver4.1.fm/4
Characteristics 1 AS-Interface cabling system 1
Dedicated componentsLA9 Z, AS-Interface V1For D.O.L. starters
General system environmentInterface type LA9 Z32810 LA9 Z32811
Product certifications AS-Interface N° 18701 AS-Interface N° 18601
Protective treatment “TH”Degree of protection Conforming to IEC 60539 IP 20
Ambient air temperaturearound the device
Storage, conforming to IEC 60539 °C - 40…+ 85Operation °C - 10…+ 55
Maximum operating altitude Without derating m 2000
Flame resistance Conforming to IEC 60695-2-1 °C 960Resistance to externalmechanical impact
1/2 sine wave, 11msconforming to IEC 60068-2-6
15 gn
Vibration resistance 5…150 Hzconforming to 60068-2-6
2 gn
Immunity to non-dissipatingshockwave (Uimp)
Conforming to IEC 60439-1 kV 2.5: AS-Interface, 24 V and on inputs/outputs
Immunity toelectrostatic discharge
Conforming to IEC 61000-4-2EN 61 000-4-2
kV 8: in open air (level 3)4: in indirect mode (level 2)
Immunity tofast transient currents
Conforming to IEC 61000-4-4EN 61 000-4-4 level 4
kV 2: AS-Interface, 24 V and on inputs/outputs
Immunity todissipated shock wave
Conforming to IEC 61000-4-5EN 61 000-4-5
kV 2: AS-Interface, 24 V and on inputs/outputs
Immunity to conductedradio-frequency interference
Conforming to IEC 61000-4-6ENV 50 141
V/m 10
Immunity to radiatedradio-frequency interference
Conforming to IEC 1000-4-3ENV 50 140 and ENV 50 204(GSM)
V/m 10
Radio-conducted andradio-radiated rejection
ENV 55 011/CISPR (G1) Class A
AS-Interface supply V 29.5-31.6
Cabling c.s.a., AS-Interface Flexible cable mm2 2 x 0.5…0.75Cabling c.s.a., 24 V Flexible cable mm2 2 x 0.5…0.75
Cabling c.s.a., input/output Flexible cage terminaland flexible cable
mm2 0.08…2.5; AWG28…12
Input current mA 7
Coincidence of inputs 100 %Maximum length of wires to switching components m 0.4
Maximum current of outputs c 13/14, (24 V) A 0.5Thermal current Ith A 2Coincidence of outputs 100 %
Short-circuit protection By flywheel diode YesOutputs switched offin event of interferenceon the AS-Interface line
Watchdog Yes
AS-Interface profile 3 F 7 F
Number of I/O 2 inputs/1 output 4 inputs/2 outputsCurrent consumption On AS-Interface On/OFF mA 8…12 8…12
Data bits Status 0 1 0 1Command D0 (O) Out 1 Off On Off On
D1 (O) Out 2 Not used Off On
D2 (O) Out 3 Not usedD3 (O) Out 4 Not used
Status D0 (I) In 1 Absent Present Absent PresentD1 (I) In 2 Absent Present Absent PresentD2 (I) In 3 Not used Absent Present
D3 (I) In 4 Not used Absent PresentParameters P0…P3 Not used
Presentation :pages 24584/2 and 24584/3
References :page 24584/5
Dimensions, schemes :pages 24584/6 and 24584/7
24584-EN_Ver4.1.fm/5
References 1 AS-Interface cabling system 1
Dedicated componentsLA9 Z, AS-Interface V1For D.O.L. starters
AS-Interface modules (1) (2)No. ofchannels
Numberof inputs
Numberof outputs
Outputvoltage
Currentper output
Reference Weight
V A kg3 2 1 c 24 0.5 LA9 Z32810 0.070
6 4 2 c 24 0.5 LA9 Z32811 0.070
AccessoriesDescription Busbar
systemWidth Reference Weight
mm mm kgModules withoutelectrical connection,for use with allLA9 Zpp adapters
40 or 60 45 LA9 Z32744 0.044
54 LA9 Z32745 0.051
Module withPE + N polarity and5-way connector
40 45 LA9 Z32740 0.091
54 LA9 Z32741 0.098
60 45 LA9 Z32742 0.085
54 LA9 Z32743 0.092
Replacement connectors and adapter cableDescription Colour Sold in
lots ofUnitreference
Weightkg
Insulation DisplacementConnector (IDC) for AS-Interface
Yellow 5 LA9 Z32825 0.100
Insulation DisplacementConnector (IDC)for auxiliary supply
Black 5 LA9 Z32826 0.100
Description Cable length Reference Weight
m kgAdapter cable for connection toaddressing terminal XZ MC11
0.5 XZ MG12 0.070
(1) User's Manual to be ordered separately, please consult your Regional Sales Office.(2) Supplied with connectors LA9 Z32825 and LA9 Z32826.
Presentation :pages 24584/2 and 24584/3
Characteristics :page 24584/4
Dimensions, schemes :pages 24584/6 and 24584/7
24584-EN_Ver4.1.fm/6
Dimensions,mounting 1
AS-Interface cabling system 1
Dedicated componentsLA9 Z, AS-Interface V1For D.O.L. starters
DimensionsLA9 Z3281p
Mounting on modulesLA9 Z32742, LA9 Z32743 LA9 Z32740, LA9 Z3274160 mm busbar system 40 mm busbar system
Common front face view
LA9 a
Z32740, Z32742 45
Z32741, Z32743 54
LA9 Z32745 LA9 Z3274440 or 60 mm busbar system
Common front face view
LA9 a
Z32745 54
Z32744 45
86 45
65 69,5
135,5
80
120
125,5
80
40
115
a
30
135,5
80
125,5
80
40
a
Presentation :pages 24584/2 and 24584/3
Characteristics :page 24584/4
References :page 24584/5
24584-EN_Ver4.1.fm/7
Schemes 1 AS-Interface cabling system 1
Dedicated componentsLA9 Z, AS-Interface V1For D.O.L. starters
D.O.L. starter, non-reversing1 motor 2 motors
D.O.L. starter, reversing
– KM
IN1
– X
3, 1
IN2
– X
3, 2
IN +
– X
3, 3
M –
– X
4, 4
– Q
LA9 Z32810
– KM
OU
T1
– X
4, 2
– Q
M
U WV
2/T
1
6/T
3
4/T
2
1/L1
5/L3
3/L2
– KM
– Q
– Q1
M1
U WV
2/T
1
6/T
3
4/T
2
1/L1
5/L3
3/L2
– KM1
– Q2
M2
U WV
2/T
1
6/T
3
4/T
2
1/L1
5/L3
3/L2
– KM2
– KM2 – Q1 – Q2
IN1
– X
3, 1
IN2
– X
3, 2
IN3
– X
3, 3
IN4
– X
3, 4
LA9 Z32811
– KM1
OU
T2
– X
3, 8
M –
– X
3, 6
OU
T1
– X
3, 7
IN +
– X
3, 5
– KM1
– KM2
– Q1 – Q2
– KM2 – Q
IN1
– X
3, 1
IN2
– X
3, 2
IN3
– X
3, 3
IN4
– X
3, 4
LA9 Z32811
– KM1
OU
T2
– X
3, 8
M –
– X
3, 6
OU
T1
– X
3, 7
IN +
– X
3, 5
– Q
M
U WV
2/T
1
6/T
3
4/T
2
1/L1
5/L3
3/L2
– KM1 – KM2
– KM2– KM1
– KM2
– KM1– Q
Presentation :pages 24584/2 and 24584/3
Characteristics :page 24584/4
References :page 24584/5