120VAC, 60Hz INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.• Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.• Toavoidoverheatingandpossibledamagetothisdeviceandotherequipment,donotinstalltocontrolareceptacle,fluorescentlighting,amotor-ora
transformer-operatedappliance.• ForHi-lume® or Eco-10®(EcoSeries)electronicballastapplications,useinstructionsheetthatcomeswiththedimmerformulti-locationapplications.• Vizia+™remotesarenotcompatiblewithstandard3-wayor4-wayswitches.TheymustbeusedwithcompatibleVizia+™orViziarf+™devicesformulti-location
switching.
WARNINGS AND CAUTIONS:• Useonlyone(1)Vizia+™dimmerinamulti-locationcircuitwithupto9coordinatingremoteswithoutLEDsorupto4matchingremoteswithLEDs.Theremote(s)
willturnthelightonatthebrightnesslevelselectedatthedimmer.• Recommendedminimumwallboxdepthis2-1/2".• Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft(90m).• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingfixture.• Usethisdeviceonlywithcopperorcoppercladwire.WithaluminumwireuseonlydevicesmarkedCO/ALRorCU/AL.
Tools needed to install your Remote:
Slotted/PhillipsScrewdriver ElectricalTapePliers PencilCutters Ruler
INSTALLING YOUR REMOTE
NOTE:UsecheckboxeswhenStepsarecompleted.
Step 1 WARNING: TO AvOID fIRE, ShOCk, OR DEATh; TURN Off pOWER atcircuitbreakerorfuseandtestthatpowerisoffbeforewiring!
3
5
1
2
6
4
2
4
1
5
3
4-Way1. FirstTraveler–notecolor2. SecondTraveler–tagged3. Neutral4. Ground5. ThirdTraveler–notecolor6. FourthTraveler–taggedNOTE:Formatchingremotew/LEDsinstallation,thefirstTravelerbecomesLineHot.
3-Way1. Line or Load (See important instruction below)2. Neutral3. Ground4. FirstTraveler–notecolor5. SecondTraveler–notecolorNOTE:Formatchingremotew/LEDsinstallation,thefirst TravelerbecomesLineHot.
Identifying your wiring application (most common):
NOTE:Ifthewiringinthewallboxdoesnotresembleanyoftheseconfigurations,consultaqualifiedelectrician.
Step 2
IMpORTANT:
for 3-Way applications,notethatoneofthescrewterminalsfromtheoldswitchbeingremovedwillusuallybeadifferentcolor(Black)orlabeledCommon.Tagthatwirewithelectricaltapeandidentifyasthecommon(LineorLoad)inboththedimmerwallboxandremotewallbox.
for 4-Way applications,notethattheoldswitchbeingremovedwillhave4screwsplusagroundscrew.Tagthetwosamecolorinsulated wires with electrical tape.
3-Way Wiring with Matching Remote (w/LEDs) Application:NOTE: IncandescentandMagneticLowVoltageinstallations only.NOTE: Screw terminal dimmer depicted.
Step 4a
Coordinating Remote Dimmer
Bk
RDYL/RD
TerminalScrew marked
Black (Bk)
TerminalScrew marked
Red (RD)
TerminalScrew marked
Yellow/Red(YL/RD)
2
4
3
5
1Bk
RDYL/RD
2
4
3
5
1
hot (Black)
Neutral (White)
Load
DimmerCoordinating Remote (no LEDs)
YL/RD YL/RDRD
Wh
RD
BkBk
Black
not used
White
Line 120vAC, 60hz
GreenGround Green
Ground
3-Way Wiring with Coordinating Remote (no LEDs) Application:NOTE: IncandescentandMagneticLowVoltageinstallations only. NOTE: Screw terminal dimmer depicted.
Step 4b
NOTE:ThedimmermustbeinstalledinawallboxthathasaLoadconnection.Thematchingremotemustbeinstalledinawallboxwitha Line Hot connection and a Neutral connection. A Neutral wire to the matchingremoteneedstobeaddedasshown.Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.NOTE:Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft.Wiring Matching Remote (wall box with Line hot connection): Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHot(common)wallboxwireidentified(tagged)whenremoving
oldswitchandFirstTravelertoremoteterminalscrewmarked“BK” ortheBlackdimmerlead.
• SecondTravelerwallboxwirefromdimmertoremoteterminalscrewmarked“YL/RD”(note wire color).Thistravelerfromtheremotemustgototheterminalscrewonthedimmermarked “YL/RD”ortheYellow/Reddimmerlead.
• LineNeutralwallboxtoremoteterminalscrewmarked“WH”.
Wiring Dimmer (wall box with Load connection): Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreen dimmer lead.
• Loadwallboxwireidentified(tagged)whenremovingoldswitchtodimmerterminalscrewmarked“RD”ortheReddimmerlead.
• FirstTravelerLineHottodimmerterminalscrewmarked“BK”ortheBlackdimmerlead.
• RemoveRedinsulatinglabelfromterminalscrewmarked“YL/RD”orYellow/Reddimmerlead.
• SecondTravelerwallboxwire(notecolorasabove)todimmerterminalscrewmarked“YL/RD”ortheYellow/Reddimmerlead.Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked“YL/RD”.
• ProceedtoStep6.
Step 4d cont’d
Cut(if necessary)
preparing and connecting wires:Thisremotecanbewiredusingsidewireterminalscrewsorthroughbackwireopenings.Chooseappropriatewirestrippingspecificationsaccordingly.
Step 3
Side Wire ConnectionSide wire terminals accept #14AWGsolidcopperwireonly.
Back Wire (either hole may be used)Backwireopeningsuse #14-12AWGsolidcopperwireonly.
5/8"(1.6 cm) Strip Gage (measure bare wire here or
use gage on back of the dimmer)
• Makesurethattheendsofthewiresfromthewallboxarestraight (cut if necessary).
• Removeinsulationfromeachwireinthewallboxasshown.
PK-93461-10-00-2A
Changing the color of your Device:Yourdevicemayincludecoloroptions.Tochangecolorofthefaceproceedasfollows:
push in side at tab to release
Line up tabs and press in sides one at a time to attach
Bk
RDYL/RD
4
3
2
1
5
DimmerMatching RemoteTerminal
Screw markedWhite (Wh)
AdditionalNeutral Wire
Bk
RDYL/RD
4
3
1
2
5
TerminalScrew marked
Black (Bk)
TerminalScrew marked
Yellow/Red(YL/RD)
hot (Black)
Neutral (White)
Load
DimmerMatching Remote (w/LEDs)
YL/RD YL/RDRD
Wh Bk Bk
Black
White
Line 120vAC, 60hz
GreenGround
GreenGround
Step 2 cont’d
WIRING DIMMER: Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer canbeinstalledoneithertheLineorLoadsideofthe3-waycircuit.NOTE:Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrewor
Green dimmer lead.• LineHot(common)wallboxwireidentified(tagged)whenremoving
oldswitchtodimmerterminalscrewmarked"BK"orBlackdimmerlead.
• FirstTravelerwallboxwiretoterminalscrewmarked"RD"orReddimmer lead (note wire color).Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked"RD".
• RemoveRedinsulatinglabelfromterminalscrewmarked "YL/RD"orYellow/Reddimmerlead.
• SecondTravelerwallboxwiretoterminalscrewmarked"YL/RD"orYellow/Reddimmerlead(note wire color).Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked"YL/RD".
WIRING COORDINATING REMOTE: Connect wires per WIRING DIAGRAM as follows:
NOTE:Maximumwirelengthfromdimmertolastremoteis 300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Loadwallboxwireidentified(tagged)whenremovingoldswitchto
terminalscrewmarked"BK".• FirstTravelerwallboxwire(note color as above) to terminal screw
marked"RD".Thistravelerfromtheremotemustgototheterminalscrewonthedimmermarked"RD"orReddimmerlead.
• SecondTravelerwallboxwire(note color as above) to terminal screwmarked"YL/RD".Thistravelerfromtheremotemustgototheterminalscrewonthedimmermarked"YL/RD"orYellow/Reddimmer lead.
• Remoteterminalscrewmarked"WH"shouldhaveWhiteinsulationlabelaffixed.
NOTE:Ifinsulatinglabelisnotaffixedtoterminalscrewmarked"WH",useelectricaltapetocover.
• proceed to Step 6.
3-Way Wiring with Matching Remote (w/LEDs) for Controls with Neutral Connection Application:NOTE:ElectronicLowVoltage,Mark10™,QuietFanSpeed and Electronic Switch installations only. NOTE: Dimmer is depicted.
Step 4c
4
3
5
ControlMatching Remote
Black
Green
White
Red
Yellow/Red
1
2
TerminalScrew marked
White (WH)AdditionalNeutral Wire
BK
RDYL/RD
4
3
1
2
5
TerminalScrew marked
Black (BK)
TerminalScrew marked
Yellow/Red(YL/RD)
Hot (Black)
Neutral (White)
ControlcMat hing Remote (w/LEDs)
YL/RD Yellow/RedRed
WH BK Black
Black
White
LoadLine
120VAC, 60Hz
White
GreenGround
GreenGround
NOTE:ThecontrolmustbeinstalledinawallboxthathasaLoadconnection.Thematchingremotemustbeinstalledinawallboxwitha Line Hot connection and a Neutral connection. A Neutral wire to the matchingremoteneedstobeaddedasshown.Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.NOTE:Maximumwirelengthfromcontroltoallinstalledremotescannotexceed300ft(90m).WIRING MATChING REMOTE (wall box with Line hot connection):Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHot(common)wallboxwireidentified(tagged)whenremoving
oldswitchandFirstTravelertoterminalscrewmarked"BK"orBlackdimmer lead.
• SecondTravelerwallboxwirefromcontroltoremoteterminalscrewmarked"YL/RD"(note wire color).Thistravelerfromtheremotemustgototerminalscrewmarked"YL/RD"orYellow/Redcontrollead.
• LineNeutralwallboxtoremoteterminalscrewmarked"WH".
WIRING DIMMER (wall box with Load connection):Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreen control lead.
• Loadwallboxwireidentified(tagged)whenremovingoldswitchtoterminalscrewmarked"RD"orRed control lead.
• FirstTravelerLineHottoterminalscrewmarked"BK"orBlackcontrol lead.
• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"orYellow/Redcontrollead.
• SecondTravelerwallboxwire(note color as above) to terminal screwmarked"YL/RD"orYellow/Redcontrollead.Thistravelerfromthecontrolmustgototheterminalscrewontheremotemarked"YL/RD".
• Lineneutralwallboxwiretoterminalscrewmarked"WH"orWhite control lead.
• proceed to Step 6.
BK
RDYL/RD
ControlCoordinating Remote
3
1
3
4
5
Black
White
Green
Red
Yellow/Red
21
4
TerminalScrew marked
White (WH)
TerminalScrew marked
Yellow/Red(YL/RD)
2
5
Hot (Black)
Neutral (White)
ControlrCoo dinating Remote (no LEDs)
YL/RD YL/RDRD
White
Red
Black
Black
BKWH
White
LoadLine
120VAC, 60Hznot used
not used
GreenGround
GreenGround
3-Way Wiring with Coordinating Remote (no LEDs) for Controls with Neutral Connection Application:NOTE:ElectronicLowVoltage,Mark10™,QuietFanSpeedandElectronicSwitchinstallationsonly.NOTE: Dimmer is depicted.
Step 4d
WIRING CONTROL: Connect wires per WIRING DIAGRAM as follows:
NOTE:ThecontrolmustbeinstalledinawallboxthathasaLineHotConnection.NOTE:Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrewor
Green control lead.• LineHot(common)wallboxwireidentified(tagged)whenremoving
oldswitchtoterminalscrewmarked"BK"orBlackcontrollead.• FirstTravelerwallboxwiretoterminalscrewmarked"RD"orRed
control lead (note wire color).• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"
orYellow/Redcontrollead.• SecondTravelerwallboxwiretoterminalscrewmarked"YL/RD"
orYellow/Redcontrollead(note wire color).Thistravelerfromthecontrolmustgototheterminalscrewontheremotemarked"YL/RD".
• LineNeutralwallboxwiretoterminalscrewmarked"WH"orWhitecontrol lead.
WIRING COORDINATING REMOTE: Connect wires per WIRING DIAGRAM as follows:
NOTE:"BK"and"RD"terminalsoncoordinatingremoteareunused.Tightenbothscrews.NOTE:Maximumwirelengthfromcontroltolastremoteis 300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Loadwallboxwireidentified(tagged)whenremovingoldswitch
toFirstTraveler(note color as above).• SecondTravelerwallboxwire(note color as above) to terminal
screwmarked"YL/RD".Thistravelerfromtheremotemustgototheterminalscrewmarked"YL/RD"orYellow/Redcontrollead.
• RemoveWhiteinsulatinglabelfromterminalscrewmarked"WH".
• LineNeutralwallboxwiretoterminalscrewmarked"WH".• proceed to Step 6.
4-Way Wiring with Matching Remote (w/LEDs) Application:NOTE:IncandescentandMagneticLowVoltageinstallations only.NOTE: Screw terminal dimmer depicted.
Step 5a
Bk
RDYL/RD
Bk
RDYL/RD
4
3
2
1
5
Matching Remote(3-Way Wall box from Step 2)
Matching Remote(4-Way Wall box from Step 2)
Dimmer(3-Way Wall box from Step 2)
4
3
5
AdditionalNeutral Wire
TerminalScrew marked
Black (Bk)
TerminalScrew marked
White (Wh)
6
2
1
TerminalScrew marked
White (Wh)AdditionalNeutral Wire
Bk
RDYL/RD
4
3
1
2
5
TerminalScrew marked
Black (Bk)
TerminalScrew marked
Yellow/Red(YL/RD)
TerminalScrew marked
Yellow/Red(YL/RD)
hot (Black)
Neutral (White)
Load
DimmerMatching Remote
(w/LEDs)Matching Remote
(w/LEDs)
YL/RDYL/RD YL/RDRD
WhWh BkBk Bk
Black
White
Line 120vAC, 60hz
GreenGround
GreenGround
GreenGround
NOTE:ThedimmermustbeinstalledinawallboxthathasaLoadconnection.Thematchingremotemustbeinstalledinawallboxwith a Line Hot connection and a Neutral connection. A Neutral wire tothematchingremoteneedstobeaddedasshown.Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.NOTE:Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft(90m).WIRING MATChING REMOTE (4-Way wall box with Line hot connection): Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• FirstTravelerandThirdTravelerwallboxwirefromdimmerin
the3-wayboxtoremoteterminalscrewmarked"BK"inthe 4-waybox,andtotheterminalscrewmarked"BK"oftheremainingremoteinthe3-waybox.
• SecondTraveler(tagged)andFourthTraveler(tagged)wallboxwirefromdimmerinthe3-wayboxtoremoteterminalscrewmarked"YL/RD"inthe4-waybox,andtotheterminalscrewmarked"YL/RD"oftheremainingremoteinthe3-waybox(note wire colors).Thistravelerfromtheremotesmustgototheterminalscrewonthedimmermarked"YL/RD"ortheYellow/Reddimmer lead.
• LineNeutralwallboxwiretoremoteterminalscrewmarked"WH".
WIRING MATChING REMOTE (3-Way wall box with Line hot connection): Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHot(common)wallboxwireidentified(tagged)when
removingoldswitchandFirstTravelerdimmerterminalscrewmarked"BK"ortheBlackdimmerlead.
• SecondTravelerwallboxwirefromdimmertoremoteterminalscrewmarked"YL/RD"(note wire color as above).Thistravelerfromtheremotemustgototheterminalscrewonthedimmermarked"YL/RD"ortheYellow/Reddimmerlead.
• LineNeutralwallboxwiretoremoteterminalscrewmarked"WH".
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
LevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenefitofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforfiveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchfiveyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemtoLeviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck parkway, Little Neck, New York 11362-2591.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandfitnessforaparticularpurpose,islimitedtofiveyears. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.
NOTE:Dresswireswithabendasshownindiagraminordertorelievestresswhenmountingdevice.• Restorepoweratcircuitbreakerorfuse.• Seeapplicableoperationsectiontoensuredimmerorswitchisfunctioningproperly.
If lights do not turn ON, refer to the TROUBLEShOOTING section.•
for additional information, contact Leviton’s Techline at 1-800-824-3005 or visit Leviton’s website at www.leviton.com
CoveredbyoneormoreUS&ForeignPatentsandpatentspendingCopyright©2007LevitonManufacturingCo.,Inc.
AllRightsIncludingTradeDressRightsReservedEco-10™(EcoSeries)isatrademarkandHi-lume®isaregisteredtrademarkof
LutronElectronicsInc.
PK-93461-10-00-2A
Restore power:Restorepoweratcircuitbreakerorfuse.Installation is complete.
Step 8
Dimmer Remote Mounting:TURN Off pOWER AT CIRCUIT BREAkER OR fUSE.
Step 7
Installationmaynowbecompletedbytighteningmountingscrewsintowallbox.Attachwallplate.
vp00R Dimmer Remote Operation (Device may be unlighted):
NOTE:ThelightswillturnONatbrightnesssetondimmer’sDIM/BRIGHTbar.Thelightingcanbeswitchedfromeitherthedimmerortheremotelocation.
OpERATION
CLEANING: Clean with a damp cloth. DO NOT use chemical cleaners.
• Lights flickering -Lamphasabadconnection. -Wiresnotsecuredfirmlyunderterminalscrewsofdimmerand/orremote.• Light does not turn ON and Locator LED does not turn ON -Circuitbreakerorfusehastripped. -Lampisburnedout. - Lamp Neutral connection is not wired.• Intermittent dimmer operation -Minimumloadisunder40W.• Remote does not operate lights -Ensurethattotalwirelengthdoesnotexceed300ft(90m). -EnsurethatonlyCoordinatingRemotesareusedwithViziarf+™devices
TROUBLEShOOTING
WIRING DIMMER (3-Way wall box with Load connection): Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreendimmerlead.
• Loadwallboxwireidentified(tagged)whenremovingoldswitchtodimmerterminalscrewmarked"RD"ortheReddimmerlead.
• FirstTravelerLineHottodimmerterminalscrewmarked"BK"ortheBlackdimmerlead.
• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"ortheYellow/Red dimmer lead.
• SecondTravelerwallboxwire(note color as above) to dimmer terminal screw marked"YL/RD"ortheYellow/Reddimmerlead.Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked"YL/RD".
• proceed to Step 6.
Step 5a cont’d 4-Way Wiring with Matching Remote (w/LEDs) Application:
Bk
RDYL/RD
3
TerminalScrew marked
Red (RD)
TerminalScrew marked
Yellow/Red(YL/RD)
Coordinating Remote(3-Way Wall box from Step 2)
Coordinating Remote(4-Way Box from Step 2)
Dimmer(3-Way Wall Box from Step 2)
62
15
4
Bk
RDYL/RD
TerminalScrew marked
Black (Bk)
TerminalScrew marked
Red (RD)
TerminalScrew marked
Yellow/Red(YL/RD)
2
4
3
5
1 Bk
RDYL/RD
2
4
3
5
1
hot (Black)
Neutral (White)
Load
DimmerCoordinating Remote
(no LEDs)Coordinating Remote
(no LEDs)
YL/RDYL/RD YL/RDRDRD
WhWh
RD
BkBkBk
Black
not used
White
Line 120vAC, 60hz
not used not used
GreenGround
GreenGround
GreenGround
Step 5b 4-Way Wiring with Coordinating Remote (no LEDs) Application:NOTE:IncandescentandMagneticLowVoltageinstallationsonly. NOTE: Screw terminal dimmer depicted.
WIRING COORDINATING REMOTE (4-Way box):Connect wires per WIRING DIAGRAM as follows:NOTE:Maximumwirelengthfromdimmertolastremoteis300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• FirstTravelerandThirdTravelerwallboxwire(note wire colors) to terminal
screwmarked"RD".Thesetravelersfromtheremoteinthe4-wayboxmustgototheterminalscrewonthedimmermarked"RD"orReddimmerlead,andtotheterminalscrewmarked"RD"oftheremainingremoteinthe3-waybox.
• SecondTraveler(tagged)andFourthTraveler(tagged)wallboxwire(note wire colors)toterminalscrewmarked"YL/RD".Thesetravelersfromtheremoteinthe4-wayboxmustgototheterminalscrewonthedimmermarked"YL/RD"ortheYellow/Reddimmerlead,andtotheterminalscrewmarked"YL/RD"oftheremainingremoteinthe3-waybox.
• Remoteterminalscrewmarked"WH"shouldhaveWhiteinsulationlabelaffixed. NOTE:Ifinsulatinglabelisnotaffixedtoterminalscrewmarked"WH",use
electricaltapetocover.Remoteterminalscrewmarked"BK"isnotused.Useelectricaltapetocover.
WIRING DIMMER (3-Way box):Connect wires per WIRING DIAGRAM as follows:NOTE:WhenusingthecoordinatingremotewithoutLEDs,thedimmercanbeinstalledoneithertheLineorLoadsideofthe3-waycircuit.NOTE:Maximumwirelengthfromdimmertoallinstalledremotescannotexceed 300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreendimmer
lead.• LineHot(common)wallboxwireidentified(tagged)whenremovingoldswitchto
dimmerterminalscrewmarked"BK"orBlackdimmerlead.• FirstTravelerwallboxwiretodimmerterminalscrewmarked"RD"orReddimmer
lead (note wire color as above).Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked"RD".
• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"orYellow/Reddimmer lead.
• SecondTravelerwallboxwiretodimmerterminalscrewmarked"YL/RD"orYellow/Red dimmer lead (note wire color as above).Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked"YL/RD".
WIRING COORDINATING REMOTE (3-Way box):Connect wires per WIRING DIAGRAM as follows:NOTE:Maximumwirelengthfromdimmertolastremoteis300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Loadwallboxwireidentified(tagged)whenremovingoldswitchtoterminalscrew
marked"BK".• FirstTravelerwallboxwire(note color as above)toterminalscrewmarked"RD".
Thistravelerfromtheremotemustgototheterminalscrewonthedimmermarked"RD"ortheReddimmerlead.
• SecondTravelerwallboxwire(note color as above)toterminalscrewmarked"YL/RD".Thistravelerfromtheremotemustgototheterminalscrewonthedimmermarked"YL/RD"ortheYellow/Reddimmerlead.
• Remoteterminalscrewmarked"WH"shouldhaveWhiteinsulationlabelaffixed. NOTE:Ifinsulatinglabelisnotaffixedtoterminalscrewmarked"WH",use
electricaltapetocover.• proceed to Step 6.
4
3
5
Black
Green
White
Red
Yellow/Red
1
2
Control(3-Way Wall Box from Step 2)
BK
RDYL/RD
Matching Remote(3-Way Wall box from Step 2)
Matching Remote(4-Way Wall box from Step 2)
4
3
5
AdditionalNeutral Wire
TerminalScrew marked
Black (BK)
TerminalScrew marked
White (WH)
6
2
1
TerminalScrew marked
White (WH)AdditionalNeutral Wire
BK
RDYL/RD
4
3
1
2
5
TerminalScrew marked
Black (BK)
TerminalScrew marked
Yellow/Red(YL/RD)
TerminalScrew marked
Yellow/Red(YL/RD)
Hot (Black)
Neutral (White)
ControlMatching Remote
(w/LEDs)
Matching Remote(w/LEDs)
YL/RDYL/RD Yellow/RedRed
WH WhiteWH BKBK Black
Line 120VAC, 60Hz
Black
White
Load
GreenGround
GreenGround Green
Ground
4-Way Wiring with Matching Remote (w/LEDs) for Controls with Neutral Connection Application:NOTE:ElectronicLowVoltage,Mark10™,QuietFanSpeedandElectronicSwitch installations only.NOTE: Dimmer is depicted.
Step 5c
NOTE:ThecontrolmustbeinstalledinawallboxthathasaLoadconnection.ThematchingremotemustbeinstalledinawallboxwithaLineHotconnectionandaNeutralconnection.ANeutralwiretothematchingremoteneedstobeaddedasshown.Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.NOTE:Maximumwirelengthfromcontroltoallinstalledremotescannotexceed 300ft(90m).
WIRING MATChING REMOTE (4-Way wall box with Line hot connection): Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• FirstTravelerandThirdTravelerwallboxwiretoremoteterminalscrewmarked"BK"
in4-waybox,andtoterminalscrewmarked"BK"oftheremainingremotein3-waybox.
• SecondTraveler(tagged)andFourthTraveler(tagged)wallboxwirefromcontrolin3-wayboxtoremoteterminalscrewmarked"YL/RD"in4-wayboxandtoterminalscrewmarked"YL/RD"oftheremainingremotein3-waybox(note wire colors).Thistravelerfromtheremotesmustgototheterminalscrewmarked"YL/RD"or Yellow/Redcontrollead.
• LineNeutralwallboxwiretoremoteterminalscrewmarked"WH".
WIRING MATChING REMOTE (3-Way wall box with Line hot connection): Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHot(common)wallboxwireidentified(tagged)whenremovingoldswitchand
FirstTravelerwallboxwiretocontrolterminalscrewmarked"BK"orBlackdimmerlead.
• SecondTravelerwallboxwirefromcontroltoremoteterminalscrewmarked"YL/RD"(note wire color as above).Thistravelerfromtheremotemustgototheterminalscrewmarked"YL/RD"orYellow/Reddimmerlead.
• LineNeutralwallboxwiretoremoteterminalscrewmarked"WH".
WIRING CONTROL (3-Way wall box with Load connection): Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreendimmerlead.• Loadwallboxwireidentified(tagged)whenremovingoldswitchtoterminalscrew
marked"RD"orRedcontrollead.• FirstTravelerLineHottoterminalscrewmarked"BK"orBlackcontrollead.• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"orYellow/Red
control lead.• SecondTravelerwallboxwire(note color as above)toterminalscrewmarked
"YL/RD"orYellow/Redcontrollead.Thistravelerfromthecontrolmustgototheterminalscrewontheremotemarked"YL/RD".
• LineNeutralwallboxwiretoterminalscrewmarked"WH"orWhitecontrollead.• proceed to Step 6.
4-Way Wiring with Coordinating Remote (no LEDs) for Controls with Neutral Connection Application:
NOTE:ElectronicLowVoltage,Mark10™,QuietFanSpeedandElectronic Switch installations only. NOTE: Dimmer is depicted.
Step 5d
WIRING CONTROL (3-Way box): Connect wires per WIRING DIAGRAM as follows:
NOTE:ThecontrolmustbeinstalledinawallboxthathasaLineHotconnection.NOTE:Maximumwirelengthfromcontroltoallinstalledremotescannotexceed300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreencontrollead.• LineHot(common)wallboxwireidentified(tagged)whenremovingoldswitchto
terminalscrewmarked"BK"orBlackcontrollead.• FirstTravelerwallboxwiretoterminalscrewmarked"RD"orRedcontrollead(note
wire color as above). • RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"orYellow/Red
control lead.• SecondTravelerwallboxwiretoterminalscrewmarked"YL/RD"orYellow/Red
control lead (note wire color as above).Thistravelerfromthecontrolmustgototheterminalscrewontheremotemarked"YL/RD".
• LineNeutralwallboxwiretoterminalscrewmarked"WH"orWhitecontrollead.
WIRING COORDINATING REMOTE (3-Way box): Connect wires per WIRING DIAGRAM as follows:
NOTE:"BK"and"RD"terminalsoncoordinatingremoteareunused.Tightenbothscrews.NOTE:Maximumwirelengthfromcontroltolastremoteis300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Loadwallboxwireidentified(tagged)whenremovingoldswitchtoFirstTraveler(note
color as above).• SecondTravelerwallboxwire(note color as above)toterminalscrewmarked
"YL/RD".Thistravelerfromtheremotemustgototheterminalscrewmarked"YL/RD"orYellow/Redcontrollead.
• RemoveWhiteinsulatinglabelfromterminalscrewmarked"WH".• LineNeutralwallboxwiretoterminalscrewmarked"WH".• proceed to Step 6.
BK
RDYL/RD
3
5
1
2
3
4
5
Black
White
Green
Red
Yellow/Red
21
14
4
3
52
TerminalScrew marked
White (WH)
TerminalScrew marked
White (WH)
TerminalScrew marked
Yellow/Red(YL/RD)
TerminalScrew marked
Black (BK)
TerminalScrew marked
Yellow/Red(YL/RD)
TerminalScrew marked
Black (BK)
Coordinating Remote(3-Way Wall box from Step 2)
Coordinating Remote(4-Way Box from Step 2)
Control(3-Way Wall Box from Step 2)
6
BK
RDYL/RD
Hot (Black)
Neutral (White)
ControlCoordinating Remote(no LEDs)
Coordinating Remote(no LEDs)
YL/RDYL/RDYL/RD RD
White
Red
Black
Black
BKWHWH
White
Line 120VAC, 60Hz
RDnot used
not used not used
not used
BK
Load
GreenGround
GreenGround
GreenGround
WIRING COORDINATING REMOTE (4-Way box): Connect wires per WIRING DIAGRAM as follows:
NOTE:"BK"and"RD"terminalsoncoordinatingremoteareunused.Tightenbothscrews.NOTE:Maximumwirelengthfromdimmertolastremoteis300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• ConnectFirstTravelerwallboxwiretoThirdTravelerwallboxwire(note wire colors)
toterminalscrewmarked"RD"ofremotein4-waybox,andtoterminalscrewmarked"RD"oftheremainingremotein3-waybox.
• ConnectSecondTravelerandFourthTravelerwallboxwire(note wire colors) to terminalscrewmarked"YL/RD"ofremotein4-waybox,andtoterminalscrewmarked"YL/RD"oftheremainingremotein3-waybox.
Thistravelerfromtheremotesmustgototheterminalscrewmarked"YL/RD"orYellow/Redcontrollead.
• RemoveWhiteinsulatinglabelfromterminalscrewmarked"WH".• LineNeutralwallboxwiretoterminalscrewmarked"WH".
Step 5d cont’d
Testing your Remote prior to completely mounting in wall box:
Step 6
push pad (Default settings)Turn ON from Off position:Tap–LightsturnONtopresetlevel.PressandHold–LightsturnONtofullbright.Turn Off from ON position:Tap–LightsturnOFF.DIM/BRIGhT BarBRIGhTEN:PressrighthalfofDIM/BRIGHTBar–Lightsbrightentodesiredlevel.DIM:PresslefthalfofDIM/BRIGHTBar–Lightsdimtodesiredlevel.Ifyoucontinuetohold,thelightswillDIMtominimumlevelandthenturnOFF.Intheeventofpoweroutageorinterruptionthelightswillresettothelastlevelwhenpowerisrestored.
DIM/BRIGhT Bar
push pad Locator Light
LED Brightness
Display
vp0SR Switch Remote Operation (Device may be unlighted):Thelightingcanbeswitchedfromeitherthedimmerortheremotelocation.
push pad (Default settings)Turn ON from Off position:Tap–LightsturnONtopresetlevel.
Turn Off from ON position: Tap–LightsturnOFF.
Intheeventofpoweroutageorinterruption the lights will reset to the last levelwhenpowerisrestored.
push pad
LocatorLight
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigitalDevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentOFFandON,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:• ReorientorrelocatethereceivingAntenna.• Increasetheseparationbetweentheequipmentandthereceiver.• Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe
receiverisconnected.• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.
fCC COMpLIANCE STATEMENT
• Positionallwirestoprovideroominoutletwallboxfordevice.
• Ensurethattheword"TOP"isfacinguponthedevicestrap.
• Partiallyscrewinmountingscrewsinwallboxmountinghole.
vp00R-1L ADvANCED pROGRAMMING fEATURES fOR USE WITh vIZIA Rf +™ ONLY
Definition of A ModesA) LEDOptions:SetssingleLED(default)orLEDBartodisplaytheloadstatus.
program Mode ATo enter program Mode A:Press and hold the Push Pad and then the righthalfoftheDIM/BRIGHTBar(^)for5secondsuntilallLEDsblink.UponreleasingthePushPadLocatorLEDwillblinkoncepersecondtoindicateProgram Mode A, LED Options.TochangetheLED Options settings, release thePushPad.ThissettingwillautomaticallybesavedandthedevicewillexitProgramming Mode.
LED Options LED Brightness/fan Speed Display
Default Single LED
Firsttoggle LEDBar