30 oil 1 / oil ∅3' blower mounted ∅22 2 1000galdw ∅19 750 ...rives.com › wp-content ›...
TRANSCRIPT
LP 5' WORK BENCH TOP
STORAGE CABINET
AIR
CONSOLE
A
AC
WA
WO
AA
OIL1
OIL2
10' SS WORKBENCH TOPSTORAGE CABINET STORAGE CABINET
LP LP
COOLKING
OILKING
PR
ES
S
POWER PUSHER
FLOORSCRUBBER
GB
12
AIR
SL210i-RA SL210i-RA
13
AIR
10' SS WORKBENCH TOPSTORAGE CABINET STORAGE CABINET
LP LP
AIR
SL210i-RA SL210i-RA
15
AIR
10' SS WORKBENCH TOPSTORAGE CABINET STORAGE CABINET
LP LP
AIR
SL210i-RA SL210i-RA
17
AIR
10' SS WORKBENCH TOPSTORAGE CABINET STORAGE CABINET
LP LP
AIR
SL210i-RA SL210i-RA
19
10' SS WORKBENCH TOPSTORAGE CABINET STORAGE CABINET
LP LP
SL210i-RA
11
14 16 18
20
SL210i-RA
10
AIR
AIR
10' SS WORKBENCH TOPSTORAGE CABINET STORAGE CABINET
LP LP
SL210i-RA
9
SL210i-RA
8
AIR
AIR
10' SS WORKBENCH TOPSTORAGE CABINET STORAGE CABINET
LP LP
SL210i-RA
7
SL210i-RA
6
AIR
AIR
10' SS WORKBENCH TOPSTORAGE CABINET STORAGE CABINET
LP LP
SL210i-RA
5
SL210i-RA
4
AIR
AIR
10' SS WORKBENCH TOPSTORAGE CABINET STORAGE CABINET
LP LP
SL210i-RA
3
SL210i-RA
2
AIR
AIR
SL210i-RA
1
AIR
A
A
OIL1
OIL2
OIL
1
OIL
2
WA
WO
AA
OILKING
OILKING
OILKING
OILKING
OILKING
OILKING
OILKING
OILKING
COOLKING
COOLKING
500/250GALDW
OIL 1 / OIL2 1000GALDW
750 gal WASTE OIL/250 gal WASTE AF
AIR
DR
YE
R
400GALREC
A/CA/C
AC
AD
TMTM
AS
TM
TM
LP LP LP LP LP LP LP LP
LP LP LP LP LP LP LP LP LP LP LP
ALP AM
WB
TC
SE
SE
SE
FT
EB
AA
AIR
Mattei Blade 7.5HPBase Mount
Mattei Blade 7.5HPBase Mount
RX
-BM
W-IS
-P
HUNTER SENSORS
Blower mountedon roof of Room 139
INGROUND TANKS
BY OTHERS
∅19"
∅3'
30"
JET
PUMP
∅22"
R.O. UNIT
BRINE
TANK
R.O.
TANK
R.O.
TANK
*
VFD
PANEL
RECLAIM
UNIT
∅2'
DRYING
AGENTSOAP
LOW
PREP
AIR
HUNTER SENSORS
CONSOLE
A
AA
AC
OIL 1
WA WOAA
750GALDW
OIL 1
OIL1
OIL2
ATF
ENCLOSEDMINI-TECHCENTER
COOLKING
OILKING
PRESS
POWER PUSHER
FLO
OR
SC
RU
BB
ER
GB
SL210i-RA
10' SS WORKBENCH TOPSTORAGE CABINET STORAGE CABINET
LP LP
LP 5' WORK BENCH TOP
STORAGE CABINET
AIRDRYER
Ma
tte
i Bla
de
7.5
HP
Ba
se M
oun
t
SYMBOL SCHEDULE FOR Dealer Solutions and Design
Symbols Description Manufacturer Model
Air Line Drop DSD Milton Type 'M'
Double Air Drop DSD Milton Type 'M'
Vehicle Lift Rotary SL210i-FA-BLACK
Compressor Mattei Blade 5
Air Dryer Nano NCR 075
W/O W/AF Pumps Graco 24E166
Air Reel Graco HPL25B
Oil Reels Graco HPM33B / 256-282 Meter
Oil Bar Graco HPM33B / 256-482 Meter
Double Wall Tank Newberry Tanks Varies on Volume / Product
Workbench Shure 780012 / 791515
Workbench Shure 780024
Alignment Rack Hunter Engineering RX-BMWIS
Alignment PowerUnit
Hunter Engineering
Alignment Cameras Hunter Engineering HE421ML
Alignment Machine Hunter Engineering WA443
Tire Changer Hunter Engineering TCR1
Wheel Balancer Hunter Engineering RFT 13BMW
Exhaust Blower Harvey Industries BD-13
Exhaust Port Harvey Industries UF-PS-30
Detail Curtain Uniglide Black / Clear / White
Oil / Coolant Drains Graco 238-866 / 248-632
Spring Compressor Brannick 7400
Bench Vise Wilton 745
Bench Grinder Wilton 577102 / 577172
Hyd Press Norco 78024 / 78025
Jack Stand Norco 81004C
Engine Stand Norco 78108
Floor Jack Norco 71202
Engine Hoist Norco 78106A
Table Lift Norco 72675
Trans Jack Norco 72550
Gas Buggy John Dow JDI-25GC / JDI-FF25
Power Pusher NuStar Power Pusher Extra Duty
Floor Scrubber Tennant T5
Electrical Tag Reference Electrical Schedule
Backsplash
R
3'-4"
2'-4"
5'-0"
3'-1 3/4"
DATA
Backsplash
R
3'-1 3/4" 3'-4"
2'-4"
R
10'-0"
7"
2'-10 5/32"
137
SERVICE
DEPARTMENT
140
CARWASH
139
AIR COMP./
FLUID STORAGE
138
ELECTRIC
ROOM
/1 A-1.9 /1 A-1.9
TYP.013
TYP.013
TYP.013
TYP.013
TYP.013
TYP.013
014
017
018
018 018 018
A AA A
013
014
006
015
016
017
• THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE WRITTEN
SPECIFICATION BOOK ISSUED AS THE COMBINED CONSTRUCTION DOCUMENTS
PACKAGE. GC SHALL NOTIFY THE ARCHITECT DURING THE BIDDING PROCESS IF THERE
IS A DISCREPANCY BETWEEN THE DRAWINGS AND SPECIFICATION BOOK.
• THIS DRAWING IS FOR INFORMATION AND COORDINATION PURPOSES ONLY - THE
GENERAL CONTRACTOR IS NOT RESPONSIBLE FOR PROVIDING THE FURNITURE OR
AUTOMOTIVE EQUIPMENT SHOWN IN THIS DRAWING UNLESS SPECIFICALLY
IDENTIFIED IN THE PLAN NOTES TO THE RIGHT.
• SEE ELECTRICAL DRAWINGS AND EQUIPMENT DRAWING (PROVIDED FOR REFERENCE
ONLY) FOR POWER REQUIREMENTS OF ALL EQUIPMENT.
• GENERAL CONTRACTOR SHALL ESTABLISH COMMUNICATION WITH THE CARWASH
SUPPLIER IMMEDIATELY AFTER BEING AWARDED THE PROJECT. ALL DIMENSIONS,
CONDUIT/PIP DIAMETERS, INSTALLATION LOCATIONS, ELECTRICAL REQUIREMENTS
SHALL BE CONFIRMED PRIOR TO CONSTRUCTION.
FURN/EQUIP. PLAN GENERAL NOTES FURN/EQUIP. PLAN KEY NOTES
PROPOSED VEHICLE EXHAUST DUCT TO BE ROUTED THROUGH THE PROPOSED
FLOOR SLAB AT THIS LOCATION. GC TO COORDINATE THIS WORK WITH THE
OWNER'S EQUIPMENT VENDOR DURING THE PRE-CONSTRUCTION PHASE.
VEHICLE EXHAUST FAN BLOWER (PROVIDED BY AUTOMOTIVE EQUIPMENT SUPPLIER)
MOUNTED ON ROOF. GC TO COORDINATE WITH MANUFACTURER AND PROVIDE A
CURB SYSTEM ON THE ROOF FOR MOUNTING. COORDINATE FINAL LOCATION WITH
AUTOMOTIVE EQUIPMENT SUPPLIER. GC TO PROVIDE DISCHARGE DUCTWORK FROM
BLOWER DOWN THROUGH ROOF (TERMINATE 30" BELOW ROOF DECK).BMW M-FIXTURE PROVIDED BY OWNER - G.C. TO COORDINATE WITH
FIXTURE VENDOR ON FLOOR MOUNTING REQUIREMENTS.
PRE-ENGINEERED BIN-SUPPORTED, METAL GRATE MEZZANINE TO BE PROVIDED BY
THE AUTOMOTIVE EQUIPMENT SUPPLIER. MEZZANINE TO BE PERMITED SEPARATELY.
METAL STAIR AND HANDRAILS PROVIDED BY AUTOMOTIVE
EQUIPMENT SUPPLIER TO MEET ALL APPLICABLE CODES.
GENERAL CONTRACTORS SCOPE OF WORK INCLUDES PROVIDING ALL ITEMS SHOWN
ON THE CARWASH DETAILED DRAWINGS EXCEPT FOR THE ACTUAL PIECES OF
CARWASH EQUIPMENT. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO ALL
UNDERGROUND CONDUIT, UNDERGROUND DRAIN/RETURN/SUCTION LINES, CONCRETE
TRENCH, RECLAIM TANK, ELECTRICAL AND PLUMBING CONNECTIONS.
• ALL NETWORK RACKS, CABLING & ACCESSORIES ARE TO BE PROVIDED BY AND
INSTALLED BY GENERAL CONTRACTOR.
• THE G.C. TO REFER TO THE IT SPECIFICATIONS AND COORDINATE ALL POWER
AND DATA LOCATIONS WITH THE MILLWORK AND FURNITURE.
• NO CONSIDERATION WILL BE GRANTED TO CONTRACTORS EXCLUDING THESE
ITEMS FROM THEIR BID SUBMISSIONS.
• FOR QUESTIONS ABOUT ANY OF THESE ITEMS PLEASE SEND A QUESTION IN THE
FORM OF AN RFI FOR FURTHER CLARIFICATION.
NETWORK RACKS, CABLING & ACCESSORIES BY G.C. - SEE IT SPECIFICATIONS
001 BMW TELEVISION FIXTURE PROVIDED BY OWNER - G.C. TO COORDINATE WITH
FIXTURE VENDOR PRIOR TO PLACING TELEVISION POWER/DATA/COAX.
002 BMW COFFEE BAR FIXTURE PROVIDED BY OWNER - G.C. TO COORDINATE WITH
FIXTURE VENDOR PRIOR TO PLACING COFFEE WATER LINE.
003 BMW COLOR BOARD FIXTURE PROVIDED BY OWNER - G.C. TO PLACE BLOCKING
IN WALL - COORDINATE WITH FIXTURE VENDOR ON MOUNTING LOCATIONS.
004 BMW EPOS INFORMATION FIXTURE PROVIDED BY OWNER - G.C. TO COORDINATE
WITH FIXTURE VENDOR PRIOR TO PLACING FLOOR MOUNTED POWER/DATA BOX.
005 BMW TELEVISION MONITOR DISPLAY FIXTURE PROVIDED BY OWNER - G.C.
TO COORDINATE WITH FIXTURE VENDOR PRIOR TO PLACING WALL
MOUNTED POWER/DATA BOX.
007 KEY MACHINE PROVIDED BY OWNER - G.C. TO COORDINATE WITH OWNER
PRIOR TO PLACING WALL MOUNTED POWER/DATA RECEPTACLES.
008 BMW SALES MANAGERS DESK PROVIDED BY OWNER - G.C. TO COORDINATE
WITH FIXTURE VENDOR ON ROUTING OF POWER/DATA AND PLACEMENT OF
POWER/DATA RECEPTACLES WITHIN DESK.
009 BMW SALES CONSULTANT ENVIRONMENT PROVIDED BY OWNER - G.C. TO
COORDINATE WITH FURNITURE/FIXTURE VENDOR ON FINAL LAYOUT PRIOR TO
PLACEMENT OF FLOOR AND WALL MOUNTED POWER/DATA RECEPTACLES.
010 BMW iCAR PLATFORM PROVIDED BY OWNER - G.C. TO COORDINATE WITH FIXTURE
VENDOR ON FINAL POWER/DATA ROUTING AND TERMINATION LOCATION.
011 BMW RECEPTION DESK CREDENZA PROVIDED BY OWNER - G.C. TO COORDINATE
WITH FIXTURE VENDOR.
012 BMW RECEPTION DESK PROVIDED BY OWNER - G.C. TO COORDINATE WITH
FIXTURE VENDOR ON ROUTING OF POWER/DATA AND PLACEMENT OF
POWER/DATA RECEPTACLES WITHIN DESK.
FLOOR PLAN LEGEND
NEW MASONRY WALL
NEW METAL STUD & GYPSUM BOARD PARTITION WALL
NEW FIRE-RATED PARTITION WALL
NEW DOOR & FRAME
DENOTES A WALL, CABINET OR EQUIPMENT ABOVE
X-1 FIXTURE TAG018 GC SHALL PROVIDE A 5'-0" WIDE "LEAVE-OUT" AT THIS LOCATION AS REQUIRED TO INSTALL
THE PROPOSED IN-GOUND LIFT EQUIPMENT. GC SHALL COORDINATE THIS WORK WITH THE
EQUIPMENT PROVIDER / INSTALLER.Plo
tte
d -
PROJECT #
DRAWN BY
CHECKED BY
SHEET DESCRIPTION:
PROJECT NAME:
NO ISSUE/REVISION DATE
FOR PERMIT/BID 9/1/15
9/1
/20
15
2:3
9:2
9 P
M
MGT
DKC
A-1.10
EQUIPMENT PLAN - NORTH
250 Killian Commons ParkwayColumbia, SC 29203
1403
BMW ofColumbia
A-1.10 SCALE: 1/8" = 1'-0"
EQUIPMENT PLAN - NORTH1
A-1.10 SCALE: 1/4" = 1'-0"
WORKBENCH ELEVATION3
A-1.10 SCALE: 1/4" = 1'-0"
WORKBENCH ELEVATION2
A-1.10 SCALE: 1/4" = 1'-0"
WORKBENCH SECTION4
WB WHEEL BALANCER HUNTER ENGINEERING 208 / 230 1 10 A USE NEMA RECEPTACLE L6-20R
TM TANK MONITOR BJ ENTERPRISES 120 1 1 A QUAD OUTLET MOUNTED 72" AFF
TS TIRE CAROUSEL SUMMIT STORAGE 460 3 10 A CONNECTIONS BY GC. DISCONNECTS PER LOCAL CODE
TC TIRE CHANGER HUNTER ENGINEERING 208 / 230 1 24 A USE NEMA RECEPTACLE L6-30R
PL PARTS LIFT CUSTOM INDUSTRIAL 460 3 10 FLA CONNECTIONS BY GC. DISCONNECTS PER LOCAL CODE.
LP LIFT POWER UNIT ROTARY LIFT 208 / 230 1 2HP / 17 A 2- CONNECTIONS BY GC. DISCONNECTS PER LOCAL CODE.
FT TRANSCEIVER GRACO 120 1 1 A DUPLEX OUTLET CEILING MOUNTED
ED ELECTRIC DRAIN MANCHESTER 120 1 2 A DUPLEX OUTLET
EB EXHAUST BLOWER HARVEY INDUSTRIES 460 3 3HP / 4ACONNECTIONS BY GC. DISCONNECTS PER LOCAL CODE. MAG
STARTER PROVIDED BY DSD, INSTALLED BY GC.
AS AIR SOLENOID GRACO 120 1 1 A DUPLEX OUTLET MOUNTED 72" AFF
AM ALIGN MACHINE HUNTER ENGINEERING 120 1 6 A DUPLEX OUTLET. ISOLATED GROUND
ALP ALIGN POWER LIFT HUNTER ENGINEERING 208 / 230 1 26 A CONNECTIONS BY GC. DISCONNECTS PER LOCAL CODE.
AD AIR DRYER NANO 120 1 11 A CONNECTIONS BY GC. DISCONNECTS PER LOCAL CODE.
AC AIR COMPRESSOR MATTEI 460 3 7.5 HP/9A2- CONNECTIONS BY GC. DISCONNECTS PER LOCAL CODE.
INCLUDES MAG STARTERS MOUNTED AND PREWIRED TO MOTORS.
SYMBOLS EQUIPMENT MANUFACTURER VOLTAGE PHASE HP/AMP COMMENTS
ELECTRICAL SCHEDULE FOR DEALER SOLUTIONS AND DESIGN