316L Stainless Steel Indirect Water Heater NO ANODE RODS NEEDED RESISTS SCALE BUILD UP LIGHT WEIGHT 316L Stainless Steel Tank Eliminates the need for anode rods Advantage Heat Exchanger Extremely durable enhanced corrugated surface: 316L stainless steel heat exchanger boasts excellent heat transfer properties, resists corrosion and offers extremely low pressure drop High Performance Can generate over 50% more hot water than many water heaters of similar size Low Energy Costs When used in conjunction with an high efficiency boiler, operating costs decrease even further Minimal Heat Loss Thanks to 2” thick, water blown foam insulation Virtually Maintenance Free Top Connections: Inlet, Outlet and Auxiliary Ports Auxiliary port for the recirculation line increases overall efficiency by eliminating short cycling of the connected boiler

Upload: others

Post on 06-Jan-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 316L Stainless Steel · The Westinghouse 80 GAL. Tank 157.5 LBS. Top Competitor’s 80 GAL. Tank 233 LBS. SCALE BUILD-UP NO Anode Rods Needed! M a d e I n c A m e r i a I • e M

316L Stainless Steel Indirect Water Heater

NO ANODE RODS NEEDED

RESISTSSCALE BUILD UP

LIGHT WEIGHT

316L Stainless Steel Tank Eliminates the need for anode rods

Advantage Heat Exchanger Extremely durable enhanced corrugated surface: 316L stainless steel heat exchanger boasts excellent heat transfer properties, resists corrosion and offers extremely low pressure drop

High Performance Can generate over 50% more hot water than many water heaters of similar size

Low Energy Costs When used in conjunction with anhigh efficiency boiler, operating costs decrease even further

Minimal Heat Loss Thanks to 2” thick, water blown foam insulation

Virtually Maintenance Free

Top Connections: Inlet, Outlet and Auxiliary PortsAuxiliary port for the recirculation line increases overall efficiency by eliminating short cycling of the connected boiler

Page 2: 316L Stainless Steel · The Westinghouse 80 GAL. Tank 157.5 LBS. Top Competitor’s 80 GAL. Tank 233 LBS. SCALE BUILD-UP NO Anode Rods Needed! M a d e I n c A m e r i a I • e M

A Closer Look!

High output corrugated surface 316L Stainless Steel heat exchanger provides maximum efficiency

Auxiliary dip tube for the recirculation line increases overall efficiency by only circulating water from the top portion of the tank

Environmentally safe, CFC free water blown, 2” thick foam insulation allows less than ½ degree F heat loss per hour

316L Stainless steel tank for high temperatures & corrosion resistance

Auxiliary port

EASY electrical connections for the thermostat

Inlet port

Surface mounted thermostat for highly accurate temperature control

Full port brass drain valve

1” FNPT boiler out

1” FNPT boiler in

Outlet port

Page 3: 316L Stainless Steel · The Westinghouse 80 GAL. Tank 157.5 LBS. Top Competitor’s 80 GAL. Tank 233 LBS. SCALE BUILD-UP NO Anode Rods Needed! M a d e I n c A m e r i a I • e M

*DOE TEST METHOD BASED ON 90º F TEMPERATURE RISE, 50º F / 140º F W/BOILER WATER AT 180º F NOTE: TANK RECOVERY FROM COLD START WILL BE BETWEEN 10-13 MINUTES WHEN S IZED WITH CORRECT FLOW RATE , BOILER S IZE AND PRESSURE DROP RATINGS FROM L IST IN ABOVE CHART. CONTINUOUS FLOW RATING CALCULATION: F IRST HOUR RATING - ( .75 * GALLON CAPACITY) = CONTINUOUS FLOW RATING

Why Choose A Stainless Steel Tank? Because They Are Built To Last!

All coated tanks require anodes to delay inevitable corrosion and tank failure. The average commercial water heater lasts about 6 years. The Westinghouse indirect stainless steel tank will outlast any coated steel tank in the market.

The Advantages

Eliminates Scale Build-up on HXProlongs Tank Life

No Need for Anode RodsLight Weight Construction

Stainless Steel vs. Glass -Lined

The Westinghouse 80 GAL. Tank

157.5 LBS.

Top Competitor’s 80 GAL. Tank

233 LBS. SCALE BUILD-UP

NO Anode Rods Needed!

Made In Am

erica • Made In

Am

eri

ca

ModelHeat

ExchangerSurface

TestPressure

Working Pressure

180º F Boiler Water 1st

Hour Rating*

180º F Boiler Btuh / Size

Recom-mended

Flow Rate

Pressure Drop at Recom-mended

Flow Rate

Weight

WI030

15 Sq. Ft.

300 PSI 150 PSI

228 G al . 95 ,700 8 GPM 1.7 Ft 95 lbs

WI040 257 G al . 122,265 10 GPM 2.3 Ft 111 lbs

WI050 287 G al . 148,830 10 GPM 2.3 Ft 127 lbs

WI060 303 G al . 155,230 10 GPM 2.3 Ft 140 lbs

WI08018 Sq. Ft.

347 G al . 192,000 12 GPM 3 Ft 157.5 lbs

WI100 387 G al . 194,000 14 GPM 3.75 Ft 231 lbs

Page 4: 316L Stainless Steel · The Westinghouse 80 GAL. Tank 157.5 LBS. Top Competitor’s 80 GAL. Tank 233 LBS. SCALE BUILD-UP NO Anode Rods Needed! M a d e I n c A m e r i a I • e M

INLET

OUTLET

AUX/RECIRC

RELIEF VALVE

THERMOSTATCONNECTION

WI-040/050/060/080/100

WI030

BOILER OUT

DRAIN VALVE

THERMOSTATACCESS

BOILER IN

1” FNPT

1” FNPT

H

G

F

A

D

C

B

E

A

D

C

B

E

INLET

OUTLET

AUX/RECIRC

RELIEF VALVE

THERMOSTATCONNECTION

WI-040/050/060/080/100

WI030

BOILER OUT

DRAIN VALVE

THERMOSTATACCESS

BOILER IN

1” FNPT

1” FNPT

H

G

F

A

D

C

B

E

A

D

C

B

E

Model A B C D E F G HTank Size

DomesticPorts

AuxPort

BoilerIn/Out

WI030 44”

19-3/8”

6-3/8” 21-1/2” 1-3/8”4” 8” 4”

30 Gal.

3/ 4” M N P T3 / 4 ”

M N P T 1 ” F N P T

WI040 56-1/2” 40 Gal.

WI050 68-3/4” 50 Gal.

WI060 54-5/8”23-1/2”

60 Gal.1” M N P T

WI080 71” 80 Gal.

WI100 64-7/8” 27-1/2” 8-5/8” 20-3/4” 2” 100 Gal. 1 1/2 ” M N P T 1” M N P T

10 Year Limited

Warranty