320 validate cos reading message - rmdsie.files.wordpress.com€¦ · 320 validate cos reading....
TRANSCRIPT
320 Validate CoS Reading
320Message Specific
Information
Message Header
320 MPRN Level Information
Message
Usage Factors 320
OptM
Register Level Info
ReqM
320 Meter ID
ReqM
320 Validate CoS Reading
Message Specific informationMessage
320 Valid CodesMeter Point StatusE – EnergisedRead Reason26 – Change of SupplierRead TypeA – An actual reading obtained by ESB NetworksE – An estimate due to no-access or a missing register readingEF – An estimate due to an implausible reading / No read availableRC – A replacement reading or estimate agreed for use by both SuppliersCU – A reading provided directly by a customerSC – A customer reading provided by a SupplierEP – An estimate due to a planned no-visitEU – An estimate due to an unplanned no-visitPlease NoteEstimate of ConsumptionThis is provided for all non MD registers and only at CoS and to the New Supplier only. This value will not necessarily be equal to the EUF for the timeslot.
Optional/Mandatory; Although the following Data Items are optional, note the following caveats:- Estimated Usage Factor: Provided for the period following the read date
320 Validate CoS Reading Segment
Message Header Message Type
Req
Version Number
Req
Transaction Reference
NumberReq
Timestamp
Req
Recipient ID
Req
Senders ID
Req
Message HeaderMessage
320 Validate CoS Reading Segment
320 MPRN Level Info
Meter Point Status
Req
MPRN
Req
Networks Reference
NumberReq
Load Profile
Req
Read Date
Req
DUoS Group
Req
320 MPRN Level InformationMessage
Market Participant Business
ReferenceOpt
Meter Configuration
CodeReq
320 Validate CoS Reading Segment
Usage Factors 320
Timeslot
Req
Usage Factors 320Message
Effective from Date
Req
Estimated Usage Factor
Opt
320 Validate CoS Reading Segment
320 Meter ID Meter Category
Opt
Serial Number
Req
320 Meter ID Message
Meter Location
Opt
320 Validate CoS Reading Segment
Meter Register Sequence
Req
Timeslot
Reading
Register Type
Req
Register Level Information
Register Level InformationMessage
Req
Req
Unit of Measurement
Req
Meter Multiplier
Req
Read Reason
Req
Read Type
Req
Previous Read Date
Req
Consumption
Opt
Read Status
Req
320 Validate CoS Reading Code
Senders ID
Senders ID
Click Here for Latest Senders ID
List
Message Message Header
320 Validate CoS Reading Code
Load ProfileMessage MPRN LevelInformation
Load Profile01 – Urban Domestic
Unrestricted
02 – Urban Domestic Day/Night
03 – Rural Domestic Unrestricted
04 – Rural Domestic Day/Night
05 – Non Domestic Unrestricted
06 – Non Domestic Day/Night
07 – MD with LF up to(but not including)
30%
08 – MD with LF greater than or equal to 30% but
less than 50%
09 – MD with LF greater than or equal
to 50%
10 – Unmetered - Flat
11 – Public Lighting Dusk/Dawn
12 – Public Lighting Dusk/Midnight
320 Validate CoS Reading Code
DUoS GroupMessage MPRN LevelInformation
DUoS GroupAGU DG1 Urban Domestic DG7 MV MDAMM DG10 Yes DG7A MV MD AutoproducerCAN DG2 Rural Domestic DG7B MV MD Importing Autoproducer or CHP
ProducerCIP DG3 Public Lighting DG8 38 kV Looped MDCOL DG4 Unmetered Supplies DG8A 38 kV Looped MD AutoproducerCOS DG5 LV Non-Domestic Non-MD DG8B 38 kV Looped MD Importing Autoproducer or
CHP ProducerCUG DG5A LV Non-Domestic Non-MD Autoproducer DG9 38 kV Tailed MD
DIJ DG5B LV Non-Domestic Non-MD Importing Autoproducer or CHP Producer
DG9A 38 kV Tailed MD Autoproducer
DSO DG6 LV MD DG9B 38 kV Tailed MD Importing Autoproducer or CHP Producer
IA DG6A LV MD Autoproducer DG10 110kV DistributionICD DG6B LV MD Importing Autoproducer or CHP
ProducerTCON Transmission Connected
320 Validate CoS Reading Code
Meter Point StatusMessage MPRN LevelInformation
Meter Point Status
A – Assigned
C - Created
D – De-Energised
E - Energised
T- Terminated
320 Validate CoS Reading Segment
Message MPRN LevelInformation Meter Configuration Code
Meter Configuration
CodeMCC01 – 24 Hour
MCC02 – P/N
MCC03 – 24h+NSH
MCC04 – D/N+W
MCC05 – MDNm/PK
MCC06 – MDNm+Pk
MCC07 –24H+NSH+W
MCC08 – 24h+W
MCC09 - Unmetered
MCC10 – QH2CH_IP
MCC11 –QH4CH_IPXP
MCC50 - NONSTN
MCC51 – D/N+NSH
MCC53 – 2 X D/N
MCC57 – 24h+D
MCC58 – 24h+D/N
MCC59 – 24h+D/N+W
MCC60 – 24h+D/N+NS
MCC61 – 2x24h
MCC62 –2x24h+NSH
MCC63 – 2x24h+D
MCC64 – 2x24h+W
MCC65 – 3x24hr
MCC67 – 3x24h+Day
MCC70 –3x24H+NSH
MCC71 – 4x24H
MCC72 – 3x24H+W
MCC73 –4x24H+NSH
MCC74 – 5x24H
MCC75 –24H+2xNSH
MCC76 – 4x24H+W
MCC77 –2x24H+W+NSH
MCC78 –3x24H+W+NSH
MCC79 –5x24H+NSH
320 Validate CoS Reading Code
Timeslot00D – 08- 23 Day
Consumption
00N – 23-08 Night Consumption
ONR – 08-21 MD Normal
OPK – 17-19 MD Peak
24H – 24 Hour Consumption
24M – 24 Hour MD
TimeslotMessage Usage Factors 320 Register Level Info
320 Validate CoS Reading Code
Meter Category
Meter CategoryMessage Meter ID 320
RM001 Single Tariff kWh RM228 Double Tarif f kWh RM511 Single Tarif f kWh RM621 C.T. Double Tarif f kWh RM752 M.F.M.RM002 Single Tariff kWh RM229 Double Tarif f kWh RM512 Single Tarif f kWh RM622 C.T. Double Tarif f kWh RM753 Double Tarif f Mechanical MD RM003 Single Tariff kWh RM230 Double Tarif f kWh RM513 Single Tarif f kWh RM623 C.T. Double Tarif f kWh RM754 M.F.M.RM004 Single Tariff kWh RM231 Double Tarif f kWh RM514 Single Tarif f kWh RM624 C.T. Double Tarif f kWh RM755 M.F.M.RM005 Single Tariff kWh RM232 Double Tarif f kWh 2 Element RM515 Single Tarif f kWh RM625 C.T. Double Tarif f kWh RM756 M.F.M.RM006 Single Tariff kWh RM233 Double Tarif f kWh 2 Element RM516 3-Phase Mechanical Single Tarif f Meter RM626 C.T. Double Tarif f kWh RM757 M.F.M.RM007 Single Tariff kWh RM234 Double Tarif f kWh RM520 Double Tarif f kWh RM627 Electronic Double Tarif f kWh RM758 M.F.M.RM008 Single Tariff kWh RM235 Double Tarif f kWh RM521 Double Tarif f kWh RM640 C.T. Single Tariff Mech anical MD RM759 M.F.M.RM010 Single Tariff kWh RM250 Electronic Double Tarif f kWh RM522 Double Tarif f kWh RM641 C.T. Single Tariff Mech anical MD RM760 M.F.M.RM011 Single Tariff kWh RM251 Double Tarif f kWh 2 Element RM523 Double Tarif f kWh RM645 M.F.M. RM761 M.F.M.RM020 Single Tariff kWh RM252 Electronic Double Tarif f kWh RM524 Double Tarif f kWh RM646 M.F.M. RM762 M.F.M.RM021 Single Tariff kWh RM253 Electronic Double Tarif f kWh (AMPY 5224E) RM525 Double Tarif f kWh RM647 M.F.M. RM763 M.F.M.RM022 Single Tariff kWh RM255 Electronic Multi rate kWh RM526 Double Tarif f kWh RM648 M.F.M. RM764 M.F.M.RM030 Single Tariff kWh RM256 Electronic Multi rate kWh RM527 Double Tarif f kWh RM649 M.F.M. RM765 M.F.M.RM031 Single Tariff kWh RM257 Electronic Multi Rate kWh RM528 Double Tarif f kWh RM650 M.F.M. RM766 M.F.M.RM032 Single Tariff kWh RM258 Electronic Multi Rate kWh RM529 Double Tarif f kWh RM651 M.F.M. RM767 M.F.M.RM033 Single Tariff kWh RM259 Electronic Multi Rate kWh RM530 Double Tarif f kWh RM652 M.F.M. RM768 M.F.M.RM034 Single Tariff kWh RM280 Hardw ired RM531 Double Tarif f kWh RM660 C.T. Double Tarif f Mechanical MD RM769 M.F.M.RM035 Single Tariff kWh RM281 DLC RM532 Double Tarif f kWh RM661 C.T. Double Tarif f Mechanical MD RM770 Single Tarif f kVArhRM036 Single Tariff kWh RM300 Smart GPRS 3Ph WC 1-20(100) RM533 Double Tarif f kWh RM662 C.T. Double Tarif f Mechanical MD RM771 Single Tarif f kVArhRM039 Single Tariff kWh RM301 Smart DLC 3PH WC 0.25-5(80)A RM534 RM534 - Electronic Double Tarif f kWh RM663 C.T. Double Tarif f Mechanical MD RM772 Single Tarif f kVArhRM040 Single Tariff kWh RM302 Smart RF 3PH WC 0.5-10(100)A RM540 Mechanical MD RM664 C.T. Double Tarif f Mechanical MD RM773 Single Tarif f kVArhRM041 Single Tariff kWh RM303 Smart RF 3PH WC 1-20(100)A RM541 Mechanical MD RM665 C.T. Double Tarif f Mechanical MD RM774 Single Tarif f kVArhRM042 Single Tariff kWh RM304 Smart PLC 3PH WC 1-20(100)A RM542 Mechanical MD RM666 C.T. Double Tarif f Mechanical MD RM775 Single Tarif f kVArhRM043 Single Tariff kWh RM350 Smart GPRS 3Ph WC 1-20(100) RM543 Mechanical MD RM667 M.F.M. RM776 Single Tarif f kVArhRM050 Electronic Single Tariff kWh RM351 Smart DLC 3PH CT 0.25-5(80)A RM545 M.F.M. RM670 C.T. kVArh RM777 Single Tarif f kVArhRM051 Single Tariff kWh Budget Controller RM352 Smart RF 3PH CT 0.5-10(100)A RM546 M.F.M. RM671 C.T. kVArh RM780 SummatorRM052 Single Tariff kWh Budget Controller RM353 Smart RF 3PH CT 1-20(100)A RM547 M.F.M. RM672 C.T. kVArh RM781 M.F.M. (PWRM/PML Ion 7600)RM054 Single Tariff kWh Budget Controller RM354 Smart PLC 3PH CT 1-20(100)A RM548 M.F.M. RM673 C.T. kVArh RM782 M.F.M. (PWRM/PML Ion 7650)RM055 Single Tariff kWh Budget Controller RM400 Single Tarif f Current Transformer kWh RM549 M.F.M. RM674 C.T. kVArh RM783 M.F.M. (PWRM/PML Ion 7650)RM056 Single Tariff kWh Budget Controller RM401 Single Tarif f Current Transformer kWh RM550 M.F.M. (Elster A1140) RM675 C.T. kVArh RM784 Summator (PSI Siemens Maxsys V2737/R33)RM066 Electronic Single Tariff kWh RM402 Single Tarif f Current Transformer kWh RM551 M.F.M. RM676 C.T. kVArh RM785 M.F.MRM067 Electronic Single Tariff kWh RM403 Single Tarif f Current Transformer kWh RM552 M.F.M. RM720 Double Tarif f kWh RMAB1 Single Phase Single Tarif f kWhRM068 Electronic Single Tariff kWh RM420 Double Tarif f Current Transformer kWh RM553 M.F.M. RM721 Double Tarif f kWh RMAB3 Single Tarif f kWhRM100 Smart GPRS 1PH WC 1-20(100)A RM421 Double Tarif f Current Transformer kWh RM570 Single Tarif f kVArh RM722 Double Tarif f kWh RMB10 Single Phase Single Tarif f kWhRM101 Smart DLC 1PH WC 0.25-5(80)A RM422 Double Tarif f Current Transformer kWh RM571 Single Tarif f kVArh RM723 Double Tarif f kWh RMB14 Single Phase Single Tarif f kWhRM102 Smart RF 1PH WC 0.5-10(100)A RM423 Double Tarif f Current Transformer kWh RM572 Single Tarif f kVArh RM740 Single Tariff Mechanical MD RMB15 Single Tarif f kWhRM103 Smart RF 1PH WC 1-20(100)A RM424 Double Tarif f Current Transformer kWh RM573 Single Tarif f kVArh RM741 Single Tariff Mechanical MD RMB16 Single Phase Single Tarif f kWhRM104 Smart RF 1PH WC 1-20(100)A RM425 Double Tarif f Current Transformer kWh RM574 Single Tarif f kVArh RM742 Single Tariff Mechanical MD RMB20 Single Phase Single Tarif f kWhRM105 Smart PLC 1PH WC 1-20(100)A RM426 Double Tarif f Current Transformer kWh RM575 Single Tarif f kVArh RM743 Double Tarif f Mechanical MD RMB34 Single Tarif f kWhRM220 Double Tarif f kWh RM500 Single Tarif f kWh RM576 Single Tarif f kVArh RM744 Double Tarif f Mechanical MD RMB36 Single Tarif f kWhRM221 Double Tarif f kWh RM501 Single Tarif f kWh RM600 C.T. Single Tariff kWh RM745 Double Tarif f Mechanical MD RMB40 Single Phase Single Tarif f kWhRM222 Double Tarif f kWh RM502 Single Tarif f kWh RM601 C.T. Single Tariff kWh RM746 Double Tarif f Mechanical MD RMB45 Single Phase Single Tarif f kWhRM223 Double Tarif f kWh RM503 Single Tarif f kWh RM602 C.T. Single Tariff kWh RM747 Double Tarif f Mechanical MD RMB60 Single Phase Single Tarif f kWhRM224 Double Tarif f kWh RM504 Single Tarif f kWh RM603 C.T. Single Tariff kWh RM748 Double Tarif f Mechanical MD RMB63 Single Tarif f kWhRM225 Double Tarif f kWh RM505 Single Tarif f kWh RM604 C.T. Single Tariff kWh RM749 Double Tarif f Mechanical MD RMB80 Single Phase Single Tarif f kWhRM226 Double Tarif f kWh RM506 Single Tarif f kWh RM617 C.T. kVArh RM750 Double Tarif f Mechanical MD RMDT1 Double Tarif f kWhRM227 Double Tarif f kWh RM510 Single Tarif f kWh RM620 C.T. Double Tarif f kWh RM751 Double Tarif f Mechanical MD RMDT3 Double Tarif f kWh
TKMTR Single Phase Single Tarif f kWh
320 Validate CoS Reading Segment
Message Meter ID 320 Meter Location
Meter Location 01 - Basement
02 - Garage
03 - Hall
04 - Kitchen
05 - Landing
06 - Office
07 – Outside box
08 - Porch
09 - Press
10 - Pumphouse
11 – Scullery/Pantry/Kitchen
12 - Shop
13 – Switchroom/Board
14 – Under Stairs
15 – Car Park
16 - Pole
17 - Lobby
18 – Shed/Outoffice/Barn
19 - Annexe
20 – Milking parlour/Dairy
21 - Workshop
22 - Store
23 – Back door
24 - Bedroom
25 – Boiler House
26 - Factory
320 Validate CoS Reading Code
Unit of MeasurementMessage Register Level Info
Unit of Measurement
K3 - kVArh
KVA - kVA
KVR - kVAr
KWH - kWh
KWT - kW
MWH - Mwh
320 Validate CoS Reading Code
Read ReasonMessage Register Level InfoMessage
Read Reason 01 - Scheduled
02 – Special Read, Chargeable
04 – Special Read to resolve dispute
09 – Special Read, non chargeable
10 – Ad-hoc, no chargeable check
read
11 – Start reading after meter re-programming
13 – De-Energisation
14 - Estimate
16 – Closing read before meter re-
programming
17 – Change of Profile
18 - Energisation
21 – Start Reading ( New Register)
22 – Closing Reading (Register removed)
23 – Meter Works Single reading
26 – Change of Supplier
27 – Change of Legal Entity
28 – Closing read before register re-
number
29 – Star read after register re-number
95 – Not for CoS
320 Validate CoS Reading Code
Read Type A - Actual
CU – Customer Reading
E – Estimate (No Access)
ED – Estimate (DUoS Billing has occurred)
EF – Estimate (Implausible/No Read available)
EP – Estimate (Block Planned)
EU – Estimate (Block Unplanned)
RC – Replacement Read
SC – Supplier Provided Customer
Reading
SU – Substitute (Interval)
Read TypeMessage Register Level Info
320 Validate CoS Reading Code
Register Type 01 – 24hr
02- Day
03 - Night
04 - NSH
05 - Wattless
06 – MD Normal
07 – MD Peak
08 – Cumulative MD Normal
09 – Cumulative MD Peak
50 – IMP QH (KW)
51 – IMP QH (kVAr)
52 – EXP QH(KW)
53 – EXP QH (kVAr)
Register TypeMessage Register Level Info
320 Validate CoS Reading Code
Message Register Level Info Read Status
Read StatusRENS – Reading
estimated – Not used for settlement
REST – Reading estimated – used for
settlement
RREL – Reading –Manually released
RV – Reading Valid
RWI – Reading Withdrawn
320 Validate CoS Reading
Version Which Implemented Description of ChangeSource of Change
10.4 MCR 1155 Message format changed from ARIS to Document format.
Message History of Changes