376 true-rms ac/dcclamp meter with iflex datasheet · 2015. 11. 17. · clamp meter with iflex ™...
TRANSCRIPT
-
Technical Data
Measurement capability• 1000Aacanddccurrent
measurementwithfixedjaw• 2500Aaccurrentmeasure-
mentwithiFlex™flexiblecurrentprobe
• 1000Vacanddcvoltagemeasurement
• True-RMSacvoltageandcurrentforaccuratemeasure-mentsonnon-linearsignals
• Frequencymeasurementto500HzwithbothjawandiFlex™
• 60kΩresistancemea-sure-mentwithcontinuitydetection
• Min,max,averageandinrushrecordingtocapturevaria-tionsautomatically
• 500mVdcmeasurementrangetointerfacewithotheraccessories
• 1000µFcapacitancemeasurement
Features• iFlex™flexiblecurrentprobe
expandsthemeasurementrangeto2500Aacwhileprovidingincreaseddisplayflexibility,abilitytomeasureawkwardsizedconductorsandimprovedwireaccess
• CATIV600V,CATIII1000Vsafetyrating
• Integratedlowpassfilterandstateoftheartsignalprocessingallowsforuseinnoisyelectricalenviron-mentswhileprovidingstablereadings
Work horse clamps with increased performance and flexibility
376 True-RMS AC/DC Clamp Meter with iFlex™
The new Fluke 376 Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With True-RMS ac voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes. Additionally, the Fluke 376 includes the new iFlex™ flexible current probe expanding the measurement range to 2500 A ac while providing increased display flexibility, ability to measure around awkward sized conductors and improved wire access. The Fluke 376 is the direct replacement for the Fluke 337 Clamp Meter.
New
-
• Proprietaryinrushmeasure-menttechnologytofilteroutnoiseandcapturemotorstartingcurrentexactlyasthecircuitprotectionseesit
• Ergonomicdesignfitsinyourhandandcanbeusedwhilewearingpersonalprotectiveequipment
• Large,easytoread,backlightdisplayautomaticallysetsthecorrectmeasurementrangesoyoudonotneedtochangeswitchpositionswhiletakingameasurement
• Three-yearwarranty• Softcarryingcase
SpecificationsFluke 376 Range Resolution Accuracy
AC current via jaw 999.9A 0.1A 2%±5digits
AC current via iFlex™ 2500A 0.1A 3%±5digits
DC current 999.9A 0.1A 2%±5digits
AC voltage 1000V 0.1V 1.5%±5digits
DC voltage 1000V 0.1mV 1%±5digits
Resistance 60,000Ω 0.1Ω 1%±5digits
Frequency 500Hz 0.1Hz 0.5%±5digits
Capacitance 1000µF 1µF 1%±4digits
True-RMS •
Continuity •
Hold •
Backlight •
Min/Max/Avg •
Inrush •
Low pass filter •
45 cm (18 inch) iFlex Flexible™ Current Probe Included
25 cm (10 inch) iFlex Flexible™ Current Probe Accessory
Wire capacity 34mm
Safety rating CATIII1000V,CATIV600V
Ordering informationFluke 376 True-RMSAC/DCClampMeterwithiFlex™
IncludedClampmeter,45cm(18-inch)iFlex™probe,testleads,softcase,usersmanual
Models Feature ChangesOldmodel:Fluke337New model: Fluke 376 Includesall337featuresplus:
•CATIV600V,CATIII1000V•iFlex™2500Aac•1000Vac/dc
•mVdc•60kΩ•1000µF
Oldmodel:Fluke336New model: Fluke 375 Includesall336featuresplus:
•CATIV600V,CATIII1000V•OptionaliFlex™2500Aac•mVdc
•60kΩ•1000µF•Min/Max/Avg
New model: Fluke 374 Includesall336features(exceptlowpassfilter)plus:•CATIV600V,CATIII1000V
•OptionaliFlex™2500Aac•1000µF•Min/Max/Avg
Oldmodel:Fluke335New model: Fluke 374 Includesall335featuresplus:
•CATIV600V,CATIII1000V•OptionaliFlex™2500Aac
•600Aac/dc•1000µF•Min/Max/Avg
New model: Fluke 373 Includesall335features(exceptinrush)plus:
•CATIV300V,CATIII600V•1000µF
Oldmodel:Fluke334New model: Fluke 374 Includesall334featuresplus:
•CATIV600V,CATIII1000V•OptionaliFlex™2500Aac•True-RMS
•600Aac/dc•1000µF•Min/Max/Avg
New model: Fluke 373 Includesall334features(exceptinrush)plus:•CATIV300V,CATIII600V
•True-RMS•1000µF
Oldmodel:Fluke333New model: Fluke 373 Includesall333featuresplus:
•CATIV300V,CATIII600V•True-RMS
•600Aac•6000Ω•1000µF
Fluke Europe B.V.P.O.Box11865602BDEindhovenTheNetherlandsWeb:www.fluke.eu
For more information call:InEurope/M-East/Africa+31(0)402675200orFax+31(0)402675222
Fluke (UK) Ltd.52HurricaneWayNorwich,NorfolkNR66JBUnitedKingdom
Tel.:(020)79420700Fax:(020)79420701E-mail:[email protected]:www.fluke.co.uk/clamps
©2010FlukeCorporation.Specificationssubjecttochangewithoutnotice.Pub_ID:11673-eng
Modification of this document is not permitted without written permission from Fluke Corporation.
Fluke. Keeping your world up and running.®