Technical Data Measurement capability 1000 A ac and dc current measurement with fixed jaw 2500 A ac current measure- ment with iFlexflexible current probe 1000 V ac and dc voltage measurement True-RMS ac voltage and current for accurate measure- ments on non-linear signals Frequency measurement to 500 Hz with both jaw and iFlex 60 kΩ resistance mea- sure-ment with continuity detection Min, max, average and inrush recording to capture varia- tions automatically 500 mV dc measurement range to interface with other accessories 1000 µF capacitance measurement Features iFlex flexible current probe expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access CAT IV 600 V, CAT III 1000 V safety rating Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environ- ments while providing stable readings Work horse clamps with increased performance and flexibility 376 True-RMS AC/DC Clamp Meter with iFlex The new Fluke 376 Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With True-RMS ac voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes. Additionally, the Fluke 376 includes the new iFlex flexible current probe expanding the measurement range to 2500 A ac while providing increased display flexibility, ability to measure around awkward sized conductors and improved wire access. The Fluke 376 is the direct replacement for the Fluke 337 Clamp Meter. New

Upload: others

Post on 30-Jan-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

  • Technical Data

    Measurement capability• 1000Aacanddccurrent

    measurementwithfixedjaw• 2500Aaccurrentmeasure-

    mentwithiFlex™flexiblecurrentprobe

    • 1000Vacanddcvoltagemeasurement

    • True-RMSacvoltageandcurrentforaccuratemeasure-mentsonnon-linearsignals

    • Frequencymeasurementto500HzwithbothjawandiFlex™

    • 60kΩresistancemea-sure-mentwithcontinuitydetection

    • Min,max,averageandinrushrecordingtocapturevaria-tionsautomatically

    • 500mVdcmeasurementrangetointerfacewithotheraccessories

    • 1000µFcapacitancemeasurement

    Features• iFlex™flexiblecurrentprobe

    expandsthemeasurementrangeto2500Aacwhileprovidingincreaseddisplayflexibility,abilitytomeasureawkwardsizedconductorsandimprovedwireaccess

    • CATIV600V,CATIII1000Vsafetyrating

    • Integratedlowpassfilterandstateoftheartsignalprocessingallowsforuseinnoisyelectricalenviron-mentswhileprovidingstablereadings

    Work horse clamps with increased performance and flexibility

    376 True-RMS AC/DC Clamp Meter with iFlex™

    The new Fluke 376 Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With True-RMS ac voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes. Additionally, the Fluke 376 includes the new iFlex™ flexible current probe expanding the measurement range to 2500 A ac while providing increased display flexibility, ability to measure around awkward sized conductors and improved wire access. The Fluke 376 is the direct replacement for the Fluke 337 Clamp Meter.

    New

  • • Proprietaryinrushmeasure-menttechnologytofilteroutnoiseandcapturemotorstartingcurrentexactlyasthecircuitprotectionseesit

    • Ergonomicdesignfitsinyourhandandcanbeusedwhilewearingpersonalprotectiveequipment

    • Large,easytoread,backlightdisplayautomaticallysetsthecorrectmeasurementrangesoyoudonotneedtochangeswitchpositionswhiletakingameasurement

    • Three-yearwarranty• Softcarryingcase

    SpecificationsFluke 376 Range Resolution Accuracy

    AC current via jaw 999.9A 0.1A 2%±5digits

    AC current via iFlex™ 2500A 0.1A 3%±5digits

    DC current 999.9A 0.1A 2%±5digits

    AC voltage 1000V 0.1V 1.5%±5digits

    DC voltage 1000V 0.1mV 1%±5digits

    Resistance 60,000Ω 0.1Ω 1%±5digits

    Frequency 500Hz 0.1Hz 0.5%±5digits

    Capacitance 1000µF 1µF 1%±4digits

    True-RMS •

    Continuity •

    Hold •

    Backlight •

    Min/Max/Avg •

    Inrush •

    Low pass filter •

    45 cm (18 inch) iFlex Flexible™ Current Probe Included

    25 cm (10 inch) iFlex Flexible™ Current Probe Accessory

    Wire capacity 34mm

    Safety rating CATIII1000V,CATIV600V

    Ordering informationFluke 376 True-RMSAC/DCClampMeterwithiFlex™

    IncludedClampmeter,45cm(18-inch)iFlex™probe,testleads,softcase,usersmanual

    Models Feature ChangesOldmodel:Fluke337New model: Fluke 376 Includesall337featuresplus:

    •CATIV600V,CATIII1000V•iFlex™2500Aac•1000Vac/dc

    •mVdc•60kΩ•1000µF

    Oldmodel:Fluke336New model: Fluke 375 Includesall336featuresplus:

    •CATIV600V,CATIII1000V•OptionaliFlex™2500Aac•mVdc

    •60kΩ•1000µF•Min/Max/Avg

    New model: Fluke 374 Includesall336features(exceptlowpassfilter)plus:•CATIV600V,CATIII1000V

    •OptionaliFlex™2500Aac•1000µF•Min/Max/Avg

    Oldmodel:Fluke335New model: Fluke 374 Includesall335featuresplus:

    •CATIV600V,CATIII1000V•OptionaliFlex™2500Aac

    •600Aac/dc•1000µF•Min/Max/Avg

    New model: Fluke 373 Includesall335features(exceptinrush)plus:

    •CATIV300V,CATIII600V•1000µF

    Oldmodel:Fluke334New model: Fluke 374 Includesall334featuresplus:

    •CATIV600V,CATIII1000V•OptionaliFlex™2500Aac•True-RMS

    •600Aac/dc•1000µF•Min/Max/Avg

    New model: Fluke 373 Includesall334features(exceptinrush)plus:•CATIV300V,CATIII600V

    •True-RMS•1000µF

    Oldmodel:Fluke333New model: Fluke 373 Includesall333featuresplus:

    •CATIV300V,CATIII600V•True-RMS

    •600Aac•6000Ω•1000µF

    Fluke Europe B.V.P.O.Box11865602BDEindhovenTheNetherlandsWeb:www.fluke.eu

    For more information call:InEurope/M-East/Africa+31(0)402675200orFax+31(0)402675222

    Fluke (UK) Ltd.52HurricaneWayNorwich,NorfolkNR66JBUnitedKingdom

    Tel.:(020)79420700Fax:(020)79420701E-mail:[email protected]:www.fluke.co.uk/clamps

    ©2010FlukeCorporation.Specificationssubjecttochangewithoutnotice.Pub_ID:11673-eng

    Modification of this document is not permitted without written permission from Fluke Corporation.

    Fluke. Keeping your world up and running.®