WHAT’S INCLUDED NOTE: ITEMS INLIST WILL BE
SHIPPEDSEPARATELY
CHECKLIST
#8 WHITE HEAD SCREWS
THRU WIRE PLUGS
JOINING KIT
LENS REMOVAL TOOL
+
JOINERCLIPS
ALIGNERTABS
LENS REMOVAL TOOL
THRU WIRE PLUG
ALIGNERTOOL
ALIGNER TOOL
#8 WHITE HEAD SCREW
ALIGNERTABS
JOINERCLIPS
THRU WIRE PLUGS
THRU WIRECONNECTORS
FIXTURE TO BE INSTALLED
INSTALLED FIXTURE
ROW MOUNTED FIXTURES - FLANGE CEILING(RG6 MODELS SHOWN)
EXPLODED VIEW
1
10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316
RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)
WARNINGSRISK OF ELECTRICAL SHOCK OR FIRE - DISCONNECT POWER DURING INSTALLATION / SERVICING.
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.INSTALL & WIRE IN ACCORDANCE TO ALL NATIONAL & LOCAL CODES BY A CERTIFIED ELECTRICIAN.
FIXTURE MAY BE SHARP - HANDLE WITH CARE.LET FIXTURE COOL BEFORE MAINTENANCE.
2
2013 Rev A
NOTE: END CAPS ARE NOTFACTORY INSTALLED ON ROWFIXTURES. SEE STEPS 6 AND 7.
JOINING KIT
REMOVE ALL PACKAGINGPRIOR TO INSTALLATION
2
1
END CAP
END CAP
APPLIES TO -3/8” TO 1 ” RIGID CEILING1/4
GENTLY BREAKAPART
10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316
RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)
4
3 ATTACHING JIG TO CEILING
CUTTING INSTALLATION
2013 Rev A
(1) MARK THE START OF THE ROW
(2) MARK THE CENTERLINE OF THE ROW
(3) INSTALL COARSE THREADDRYWALL SCREW ON CENTERLINESPACED 2” FROM START OF ROW.
(5) LIFT CUTTING JIG INTO POSITIONOVER THE FIRST SCREWS. SLIDE
SO THAT THE SCREWS ARE IN THENARROW END OF THE KEY HOLES
IN THE JIG.
NOTE: THE OBROUND CUTOUTSSHOULD BE AWAY FROM THE
START OF THE ROW.
USE 1/8” DRYWALL BIT AGAINST THE EDGEOF THE JIG. START AT THE BEGINNING OF
THE ROW AND TRACE THE JIG. ONE PERSONCUTS WHILE A SECOND PERSON HOLDS
THE CUT END FROM FALLING OUT. 1/8” DRYWALL BIT1/2” OR 5/8” DRYWALL
CUTTING JIGGUARD ISATTACHED
OBROUND HOLES CLOSEST TO THE KEYHOLEMARKS THE END OF A ROW INSTALLATION. IT
MAKES THE OPENING 5/8” LONGER THAN ROWTO ALLOW THE LAST FIXTURE INTO THE CEILING.
OBROUND HOLES FARTHEST FROMTHE KEYHOLE DO NO APPLY TO
THIS INSTRUCTION SHEET.
ROTO ZIP(OR SIMILIAR TOOL)
USE OBROUND SLOT TOMARK CUT LINE. DO NOT
TRY TO CUT THRU SLOTS.
(4) INSTALL COARSE THREADDRYWALL SCREWS ON CENTERLINESPACED 24” FROM SCREW IN STEP 3
ON CENTER DOWN THE ENTIRELENGTH OF THE ROW.
10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316
RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)
5 CUTTING INSTALLATION
END CAP INSTALLATION
2013 Rev A
RF2-... RF4-... RF6-...
2.75” 3.75” 5.75”
HOLE WIDTHS
REMOVE CUT CEILINGWITH JIG ATTACHED
6FIRST / LAST FIXTURE IN ROW
SLIDE END CAPINTO THE FIXTURE
10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316
RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)
8
7 END CAP INSTALLATION
FIXTURE INSTALLATION
2013 Rev A
FIRST / LAST INSTALLEDFIXTURE IN ROW
END CAP TAB WILL SNAP INTO SLOT
ON HOUSING
NOTE: THIS OPERATION WILLREQUIRE FORCE. AVOID DEFORMING
END CAP AND HOUSING SHEET METAL
INSTALL #8 WHITE HEADSCREWS AFTER END CAP
HAS SNAPPED INTO PLACE.
A
INSERT ALIGNMENT TABSUNTIL POINT ON TAB
STOPS INWARD MOVEMENT
DETAIL A
LUMINAIRE POWER DISCONNECT
CODE COMPLIANT, FACTORYINSTALLED POWER DISCONNECT
Input Side Daisy ChainConductor Types:
Power Side - solid / stranded19 strands (MIN.)
Ballast Side - 18 AWG solid
1. WARNING - ELECTRICAL SHOCK or FIRE - Disconnect power.2. Wire per all National and Local electrical codes. Remove access cover or knock- out and connect power feed conduit.3. Make proper electrical connection and re-install access cover.
INSERT THE LONGER ENDOF ALIGNMENT TABS INTOEXTRUSION SLOT OF THEFIXTURE TO BE INSTALLED
EXTRUSION SLOT
REPEAT FOR ALL OTHERFIXTURES IN ROW
FIXTURE TO BE INSTALLED
INSERT THRU WIRE PLUGSINTO THRU WIRE CONNECTORSON FIXTURE TO BE INSTALLED
MAKE SURE END CAP FLANGELINES UP WITH EXTRUSION EDGEAFTER SCREWS ARE INSTALLED.
10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316
RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)
9 FIXTURE INSTALLATION
FIXTURE INSTALLATION
2013 Rev A
10
NEXT, PUSH YOKE BOLTHEAD UP UNTIL YOKELEGS SNAP OUT OVER
DRYWALLFIRST, BOTTOM OUTFLANGE ON CEILING
SURFACE
INSERT FIXTURE INTOCEILING HOLE
FIRST INSTALLEDFIXTURE IN ROW
FIRST INSTALLEDFIXTURE IN ROW
AFTER YOKE LEGS HAVE SPRUNGOUTWARDS, THE FIXTURE WILL REST
ABOUT 1” BELOW THE CEILING.
AMOUNT OF YOKES PER FIXTURE: 2’/3’/4’ FIXTURE - 2 YOKES 6’/8’ FIXTURE - 3 YOKES
1. WARNING - ELECTRICAL STOCK OR FIRE - Disconnect power.2. Clean hands before handling the luminaire or use clean gloves.3. Secure luminaire per all codes. Instead of Yoke (provided): - All-thread (SBO) can be secured to structure and passed through 1/4-20 hole
- Air craft cable (SBO) can be secured to structure and passed though 1/4-20 hole
AFTER SHIFTING THE FIXTURE TO THE EDGEOF THE CEILING CUT, ONLY TIGHTEN THE
YOKE BOLT ON THE END CAPPED SIDE OF THEFIXTURE UNTIL FLANGE IS TIGHT TO CEILING.
TIGHTEN ALL YOKE BOLTS ON PREVIOUSFIXTURE ONCE NEXT FIXTURE IS INSTALLED.
NOTE: LIFT THEN SHIFT.FIXTURE SHOULD BE SETAGAINST THE EDGE OFTHE CEILING SLOT.
FIRST INSTALLEDFIXTURE IN ROW
FIRST INSTALLEDFIXTURE IN ROW
10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316
RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)
12
11 FIXTURE INSTALLATION
FIXTURE INSTALLATION
2013 Rev A
NOTE: REPEAT STEPS 9 AND 10 FOR ALL OTHERFIXTURES IN ROW, EXCEPT FOR LAST FIXTURE.
SIMULTANEOUSLY CONNECT: 1. THRU WIRE PLUGS TO THRU WIRE CONNECTORS 2. ALIGNMENT TABS INTO EXTRUSION SLOT
FIXTURE TO BE INSTALLED INSTALLED FIXTURE
PLACE UPPER TAB OF ALIGNERTOOL UNDERNEATH EXTURSION
PLACE SIDE TAB OF ALIGNER TOOLON TOP EDGE OF JOINER CLIP
ROTATE UNTIL JOINERCLIP “SNAPS” INTO PLACE
REPEAT FOR OTHER SIDE
NOTE: VIEWED FROM INSIDE THE FIXTURE
10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316
RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)
14
13FIXTURE INSTALLATION
FIXTURE INSTALLATION
2013 Rev A
1. WARNING - ELECTRICAL STOCK OR FIRE - Disconnect power.2. Clean hands before handling the luminaire or use clean gloves.3. Fold out pry out grid hookd to center and secure luminaire over ceiling grid. Set hook to match T-bar height.4. Secure luminaire per all codes. Holes are provided for tie back to structure (tie wire by others). Code may require seismic stabilizing, shown above (1/4” TEK screw by other).
NOTE: VIEWED FROM INSIDE THE FIXTURE
REPEAT FOR OTHER SIDE
FINAL RESTING POSITIONOF JOINER CLIP
SEQUENCE OF YOKE BOLT TIGHTENING
NEXT YOKE BOLTS TO BE TIGHTENED
FIRST YOKE BOLT PREVIOUSLY TIGHTENED
YOKE BOLTS TO BE TIGHTENED AFTERNEXT FIXTURE IN ROW IS INSTALLED
HOLD ALIGNER TOOL BETWEENHOUSING BEING TIGHTEN TOAVOID HOUSING DISTORTION
10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316
RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)
16
15 FIXTURE INSTALLATION
LENS REMOVALTOOL
1. WARNING - ELECTRICAL SHOCK or FIRE - Disconnect power.2. Gently insert lens removal tool at one end of the lens and pull down. Grab the exposed end and remove lens.3. Install appropriate lamp(s) and re-install the lens.4. Clean - Wipe down luminaire with a clean damp rag.5. Connect power and make sure luminaire works properly.
LAMP INSTALLATION, MAINTENANCE and CLEANING
2013 Rev A
LENS REMOVAL TOOL