38kv metal-clad medium voltage switchgear...ansi/ieee c37.20.2 metal-clad switchgear ansi/ieee...

2
Tradition. Technology. Innovation. 38kV Metal-Clad Medium Voltage Switchgear ANSI/IEEE C37.20.2 Metal-Clad Switchgear ANSI/IEEE C37.04 Rating Structure for High Voltage Circuit Breakers ANSI/IEEE C37.54 Indoor HV Breakers in Metal Enclosure Conformance Test ANSI/IEEE C37.55 Medium Voltage Metal-Clad Assemblies ANSI/IEEE C37.09 Test Procedure for AC HV Breakers on Sym Current basis CSA Listed IEM’s medium voltage product line is available in the 38kV class in indoor, outdoor non-walk-in, and outdoor enclosures. The 38kV mechanically complete switchgear rated for 40kA is also available with CSA listing when required and applicable, and tested per ASCE7-10 requirements to meet and exceed IBC & CBC codes. • Voltage: 38kV • Ampacity: 1200A, 2000A • Basic Insulation Level (BIL): 150kV (Breaker 170kV BIL) • Breaker interrupter ratings: Up to 40kAIC • NEMA 1: 42” W x 123” D x 95” H • NEMA 3R: 42” W x 132” D x 107” H • Advanced vacuum circuit breaker • Metal-clad compartmentalized construction • Main-tie-main automatic transfer scheme • Rear access for load and incoming connections • Indoor or outdoor applications • Breaker & PT can be constructed into one section (feeder only) 38KV SWITCHGEAR Product Sheet FEATURES & BENEFITS

Upload: others

Post on 31-Mar-2021

47 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: 38kV Metal-Clad Medium Voltage Switchgear...ANSI/IEEE C37.20.2 Metal-Clad Switchgear ANSI/IEEE C37.04 Rating Structure for High Voltage Circuit Breakers ANSI/IEEE C37

Tradition. Technology. Innovation.

38kV Metal-Clad Medium Voltage Switchgear

ANSI/IEEE C37.20.2 Metal-Clad Switchgear

ANSI/IEEE C37.04 Rating Structure for High Voltage Circuit Breakers

ANSI/IEEE C37.54 Indoor HV Breakers in Metal Enclosure Conformance Test

ANSI/IEEE C37.55 Medium Voltage Metal-Clad Assemblies

ANSI/IEEE C37.09 Test Procedure for AC HV Breakers on Sym Current basis

CSA Listed

IEM’s medium voltage product line is available in the 38kV class in indoor, outdoor non-walk-in, and outdoor enclosures.

The 38kV mechanically complete switchgear rated for 40kA is also available with CSA listing when required and applicable, and tested per ASCE7-10 requirements to meet and exceed IBC & CBC codes.

• Voltage: 38kV

• Ampacity: 1200A, 2000A

• Basic Insulation Level (BIL): 150kV (Breaker 170kV BIL)

• Breaker interrupter ratings: Up to 40kAIC

• NEMA 1: 42” W x 123” D x 95” H

• NEMA 3R: 42” W x 132” D x 107” H

• Advanced vacuum circuit breaker

• Metal-clad compartmentalized construction

• Main-tie-main automatic transfer scheme

• Rear access for load and incoming connections

• Indoor or outdoor applications

• Breaker & PT can be constructed into one section (feeder only)

38KV SWITCHGEARProduct Sheet

FEATURES & BENEFITS

Page 2: 38kV Metal-Clad Medium Voltage Switchgear...ANSI/IEEE C37.20.2 Metal-Clad Switchgear ANSI/IEEE C37.04 Rating Structure for High Voltage Circuit Breakers ANSI/IEEE C37

Industrial Electric Mfg.™ (IEM)

Headquartered in Fremont, CA, IEM is the largest independent full-line manufacturer of electrical distribution and integrated control systems in the U.S. For over half a century, IEM has delivered customer-specific solutions to meet the ever changing power requirements of growth industries in North America. At IEM, tradition and technology still drive innovation. An experienced engineering staff and one of the most flexible design and manufacturing systems in the industry set IEM apart from standard product manufacturers.

www.iemfg.com

Corporate Headquarters

Industrial Electric Mfg.™ 48205 Warm Springs Blvd Fremont CA 94539 USA dir: +1.510.656.1600 www.iemfg.com

Vancouver

Industrial Electric Mfg.™ 201 – 27353 58th Crescent Langley, B.C. V4W 3W7 CAN dir: +1.866.302.9836 www.iemfg.com

©2020 The New IEM LLC. Industrial Electric Mfg.™ and IEM Power Systems™ are trademarks of The New IEM LLC. in the U.S. and other countries. All rights reserved.

Jacksonville

Industrial Electric Mfg.™ 11902 Central Parkway Jacksonville FL 32224 USA dir: +1.904.365.4444 www.iemfg.com

38kV Metal-Clad Medium Voltage Switchgear

• Capacitor trip device –Internal or external when AC required

• Standard fast interruption: 3 Cycles

• SIS – 600V secondary wiring

• 4NO + 4NC auxiliary contacts

• Operation counter and charge/discharge spring indicator

• Front access to position indicator

• Safe and reliable flexible secondary disconnect signals

VACUUM CIRCUIT BREAKERA state-of-the-art ANSI/IEEE vacuum circuit breaker with full interchangeable capabilties allows for a 2000A unit that can be applied into a cubicle rated for 1200A, thus providing flexibility for operation and maintenance requirements optimized to meet specifications.

• Full Roll on the floor – No accessories required (Lift truck, ramp, etc.)

• Manual and electrical (motor) spring charging

• Front Operation and front access to operating mechanism

• AC or DC auxiliary voltage

• Under voltage release and second shunt trip optional

BREAKER RATINGS

38 KV SWITCHGEARProduct Sheet

Circ

uit B

reak

er T

ype

Rat

ed M

axim

um V

olta

ge (k

V)

Nom

inal

Vol

tage

Cla

ss (k

V)

Freq

uenc

y (H

z)

Rat

ed V

olta

ge R

ange

Fac

tor (

K)

Pow

er F

requ

ency

1 m

in (k

vrm

s)

Ligh

ting

Impu

lse

1.2X

50 μ

S (k

V)

Rat

ed C

urre

nt (A

)

Rat

ed B

reak

ing

Cur

rent

(kA

)

Rat

ed M

akin

g C

urre

nt (k

Ap)

Rat

ed S

hort

Circ

uit T

ime

With

tnad

-3 s

ec (k

A)

Rat

ed C

rest

Vol

tage

(kVC

rest

)

Rat

ed T

ime

to C

rest

(T2

μS)

Rat

ed R

ise

of R

ecov

ery

Volt

Rat

ed P

erm

isib

le T

rippi

ng D

elay

(YSe

c)

Ope

ning

Tim

e (S

ec)

Bre

akin

g Ti

me

(Cyc

les)

Rat

ed O

pera

ting

Sequ

ence

Aux

iliar

y C

onta

cts

Insulation /Withstand

Class

Operation TimeCurrent

VIDER VVA

38 34.5 60 1.0 80 170 1200A 2000A

40 104 40 65.2 109 0.6 2 0.05 3 0-C-O 4 A/B

Rated Transient Recovery Voltage

(TRV)