4 n female connector · 2 sinclair sd224 antenna 200 ldf4-soa cable 4 n female connector 6 ground...

12
Qty Description PRIME SITE 1 GGM 8000 GATEWAY 1 ADD: AC POWER 1 2610-24 ETHERNET SWITCH 1 SEVEN AND A HALF FOOT RACK POU, 120V HARDWIRE (8) 20A OUTLET POU WITH TYPE 3 SAD 1 PROTECTION 1 SM,MLC8000 MOD 1 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY 1 ADD: 120/240VAC TO +12VDC POWER ADAPTER 1 ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK POU, 120V HARDWIRE (8) 20A OUTLET POU WITH TYPE 3 SAD 1 PROTECTI ON 1 SPECTRACOM SECURESYNC TI MING W/ANTENNA SITE 1 1 GTR 8000 BASE RADIO 1 ADD: VHF (136-174 MHZ} MID POWER 1 ADD: ANALOG CONVENTIONAL SOFTWARE 1 ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE 1 ADD: RACK MOUNT HARDWARE 1 GGM 8000 GATEWAY 1 ADD: AC POWER 1 2610-24 ETHERNET SWITCH 1 SEVEN AND A HALF FOOT RACK 1 POU, 120V HARDWIRE (8) 20A OUTLET POU WITH TYPE 3 SAD 1 SM,MLC8000 MOD 1 ADD: ANALOG CONVENTIONAL SIMU L CAST COMPARATOR/GATEWAY 1 ADD: 120/240VAC TO +12VDC POWER ADAPTER 1 ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK 1 PDU, 120V HARDWIRE (8) 20A OUTLET POU WITH TYPE 3 SAD 1 POU, 120V HARDWIRE {8} 20A OUTLET PDU W ITH TYPE 3 SAD 1 SPECTRACOM S ECUR.ESYNCTIMING W/ANTENNA 2 SINCLAIR 50224 ANTENNA 200 LDF4-50A CABLE

Upload: others

Post on 22-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 4 N FEMALE CONNECTOR · 2 sinclair sd224 antenna 200 ldf4-soa cable 4 n female connector 6 ground kit 2 hoisting grip 2 3' jumper 2 25' jumper 2 nemp polyphaser 1 installation hardware

Qty Description

PRIME SITE

1 GGM 8000 GATEWAY

1 ADD: AC POWER

1 2610-24 ETHERNET SWITCH

1 SEVEN AND A HALF FOOT RACK POU, 120V HARDWIRE (8) 20A OUTLET POU WITH TYPE 3 SAD

1 PROTECTION

1 SM,MLC8000 MOD

1 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

1 ADD: 120/240VAC TO +12VDC POWER ADAPTER

1 ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK POU, 120V HARDWIRE (8) 20A OUTLET POU WITH TYPE 3 SAD

1 PROTECTION

1 SPECTRACOM SECURESYNC TIMING W/ANTENNA

SITE 1

1 GTR 8000 BASE RADIO

1 ADD: VHF (136-174 MHZ} MID POWER

1 ADD: ANALOG CONVENTIONAL SOFTWARE

1 ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

1 ADD: RACK MOUNT HARDWARE

1 GGM 8000 GATEWAY

1 ADD: AC POWER

1 2610-24 ETHERNET SWITCH

1 SEVEN AND A HALF FOOT RACK

1 POU, 120V HARDWIRE (8) 20A OUTLET POU WITH TYPE 3 SAD

1 SM,MLC8000 MOD

1 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

1 ADD: 120/240VAC TO +12VDC POWER ADAPTER

1 ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK

1 PDU, 120V HARDWIRE (8) 20A OUTLET POU WITH TYPE 3 SAD

1 POU, 120V HARDWIRE {8} 20A OUTLET PDU WITH TYPE 3 SAD

1 SPECTRACOM SECUR.ESYNCTIMING W/ANTENNA

2 SINCLAIR 50224 ANTENNA

200 LDF4-50A CABLE

Page 2: 4 N FEMALE CONNECTOR · 2 sinclair sd224 antenna 200 ldf4-soa cable 4 n female connector 6 ground kit 2 hoisting grip 2 3' jumper 2 25' jumper 2 nemp polyphaser 1 installation hardware

4 N FEMALE CONNECTOR

6 GROUND KIT

2 HOISTING GRIP

2 3' JUMPER

2 25' JUMPER

2 NEMP POLYPHASER

1 INSTALLATION HARDWARE

1 HYBRID VHF COMBINER/MULTICOUPLER

SITE 2

1 GTR 8000 BASE RADIO

1 ADD: VHF (136-174 MHZ} MID POWER

1 ADD: ANALOG CONVENTIONAL SOFTWARE

1 ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

1 ADD: RACK MOUNT HARDWARE

1 GGM 8000 GATEWAY

1 ADD: AC POWER

1 2610-24 ETHERNET SWITCH

1 SEVEN AND A HALF FOOT RACK

1 POU, 120V HARDWIRE (8) 20A OUTLET POU WITH TYPE 3 SAD

1 SM,MLC8000 MOD

1 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

1 ADD: 120/240VAC TO +12VDC POWER ADAPTER

1 ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK

1 POU, 120V HARDWIRE (8) 20A OUTLET PDU WITH TYPE 3 SAD

1 POU, 120V HARDWIRE (8) 20A OUTLET POU WITH TYPE 3 SAD

1 SPECTRACOM SECURESYNC TIMING W/ANTENNA

2 SINCLAIR SD224 ANTENNA

200 LDF4-SOA CABLE

4 N FEMALE CONNECTOR

6 GROUND KIT

2 HOISTING GRIP

2 3' JUMPER

2 25' JUMPER

2 NEMP POLYPHASER

1 INSTALLATION HARDWARE

1 HYBRID VHF COMBINER/MULTICOUPLER

SITE 3

1 GTR 8000 BASE RADIO

1 ADD: VHF (136-174 MHZ) MID POWER

1 ADD: ANALOG CONVENTIONAL SOFTWARE

1 ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

Page 3: 4 N FEMALE CONNECTOR · 2 sinclair sd224 antenna 200 ldf4-soa cable 4 n female connector 6 ground kit 2 hoisting grip 2 3' jumper 2 25' jumper 2 nemp polyphaser 1 installation hardware

1 ADO: RACK MOUNT HARDWARE

1 GGM 8000 GATEWAY

1 ADD: AC POWER

1 2610-24 ETHERNET SWITCH

1 SEVEN AND A HALF FOOT RACK

1 POU, 120V HARDWIRE (8) 20A OUTLET POU WITH TYPE 3 SAD

1 SM,MLC8000 MOD

1 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

1 ADD: 120/240VAC TO +12VDC POWER ADAPTER

1 ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACI<

1 POU, 120V HARDWIRE {8) 20A OUTLET POU WITH TYPE 3 SAD

1 POU, 120V HARDWIRE {8) 20A OUTLET POU WITH TYPE 3 SAD

1 SPECTRACOM SECURESYNC TIMING W/ANTENNA

2 SINCLAIR SD224 ANTENNA

200 LDF4-50A CABLE

4 N FEMALE CONNECTOR

6 GROUND KIT

2 HOISTING GRIP

2 3' JUMPER

2 25' JUMPER

2 NEMP POLYPHASER

1 INSTALLATION HARDWARE

1 HYBRID VHF COMBINER/MULTICOUPLER

SITE 4

1 GTR 8000 BASE RADIO

1 ADD: VHF (136-174 MHZ) MID POWER

1 ADD: ANALOG CONVENTIONAL SOFTWARE

1 ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

1 ADD: RACK MOUNT HARDWARE

1 GGM 8000 GATEWAY

1 ADD: AC POWER

1 2610-24 ETHERNET SWITCH

1 SEVEN AND A HALF FOOT RACK

1 POU, 120V HARDWIRE (8) 20A OUTLET POU WITH TYPE 3 SAD

1 SM,MLC8000 MOD

1 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

1 ADD: 120/240VAC TO +12VDC POWER ADAPTER

1 ADD: 191NCH RACK MOUNT HARDWARE l<IT CABINET OR RACK

1 PDU, 120V HARDWIRE (8) 20A OUTLET POU WITH TYPE 3 SAD

1 POU, 120V HARDWIRE {8) 20A OUTLET POU WITH TYPE 3 SAD

1 SPECTRACOM SECURESYNC TIMING W/ANTENNA

2 SINCLAIR 50224 ANTENNA

Page 4: 4 N FEMALE CONNECTOR · 2 sinclair sd224 antenna 200 ldf4-soa cable 4 n female connector 6 ground kit 2 hoisting grip 2 3' jumper 2 25' jumper 2 nemp polyphaser 1 installation hardware

200 LDF4-50A CABLE

4 N FEMALE CONNECTOR

6 GROUND KIT

2 HOISTING GRIP

2 3' JUMPER

2 25' JUMPER

2 NEMP POLYPHASER

1 INSTALLATION HARDWARE

1 HYBRID VHF COMBINER/MULTICOUPLER

SITE 5

1 GTR 8000 BASE RADIO

1 ADD: VHF (136-174 MHZ) MID POWER

1 ADD: ANALOG CONVENTIONAL SOFTWARE

1 ADD: ANALOG CONVENTIONAL SIMULCAST somVARE

1 ADD: RACK MOUNT HARDWARE

1 GGM 8000 GATEWAY

1 ADD: AC POWER

1 2610-24 ETHERNET SWITCH

1 SEVEN AND A HALF FOOT RACK

1 POU, 120V HARDWIRE (8) 20A OUTLET POU WITH TYPE 3 SAD

1 SM,MLC8000 MOD

1 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

1 ADD: 120/240VAC TO +12VDC POWER ADAPTER

1 ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK

1 PDU, 120V HARDWIRE (8} 20A OUTLET PDU WITH TYPE 3 SAD

1 POU, 120V HARDWIRE (8} 20A OUTLET PDU WITH TYPE 3 SAD

1 SPECTRACOM SECURESYNCTIMING W/ANTENNA

2 SINCLAIR SD224 ANTENNA

200 LDF4-50A CABLE

4 N FEMALE CONNECTOR

6 GROUND KIT

2 HOISTING GRIP

2 3' JUMPER

2 25' JUMPER

2 NEMP POLYPHASER

1 INSTALLATION HARDWARE

1 HYBRID VHF COMBINER/MULTICOUPLER

Page 5: 4 N FEMALE CONNECTOR · 2 sinclair sd224 antenna 200 ldf4-soa cable 4 n female connector 6 ground kit 2 hoisting grip 2 3' jumper 2 25' jumper 2 nemp polyphaser 1 installation hardware

Sheriff's Office - Two Channel Qty Description

PRIME SITE

2 SM,M LC8000 MOD

2 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

2 ADD: 120/240VAC TO+ 12VDC POWER ADAPTER

OTIER CREST

2 GTR 8000 BASE RADIO

2 ADD: VHF (136-174 MHZ) MID POWER

2 ADD: ANALOG CONVENTIONAL SOFTWARE

2 ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

2 ADD: RACK MOUNT HARDWARE

2 SM,MLC8000 MOD

2 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

2 ADD: 120/240VAC TO +12VDC POWER ADAPTER

2 ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK

2 20 AMP BREAKER

HIGHLAND

2 GTR 8000 BASE RADIO

2 ADD: VHF (136-174 MHZ) M ID POWER

2 ADD: ANALOG CONVENTIONAL SOFTWARE

2 ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

2 ADD: RACK MOUNT HARDWARE

2 SM,MLC8000 MOD

2 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

2 ADD: 120/240VAC TO +12VDC POWER ADAPTER

2 ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK

2 20 AMP BREAKER

Page 6: 4 N FEMALE CONNECTOR · 2 sinclair sd224 antenna 200 ldf4-soa cable 4 n female connector 6 ground kit 2 hoisting grip 2 3' jumper 2 25' jumper 2 nemp polyphaser 1 installation hardware

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

EU CHER

GTR 8000 BASE RADIO

ADD: VHF {136-174 MHZ) MID POWER

ADD: ANALOG CONVENTIONAL SOFTWARE

ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

ADD: RACK MOUNT HARDWARE

SM,MLC8000 MOD

ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

ADD: 120/240VAC TO +12VDC POWER ADAPTER

ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK

20 AMP BREAKER

TABLE

GTR 8000 BASE RADIO

ADD: VHF (136-174 MHZ) MID POWER

ADD: ANALOG CONVENTIONAL SOFTWARE

ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

ADD: RACK MOUNT HARDWARE

SM,MLC8000 MOD

ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

ADD: 120/240VAC TO +12VDC POWER ADAPTER

ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK

20 AMP BREAKER

PERPETUA

GTR 8000 BASE RADIO

ADD: VHF (136-174 MHZ) MID POWER

ADD: ANALOG CONVENTIONAL SOFTWARE

ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

ADD: RACK MOUNT HARDWARE

SM,MLC8000 MOD

ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

ADD: 120/240VAC TO +12VDC POWER ADAPTER

20 AMP BREAKER

Page 7: 4 N FEMALE CONNECTOR · 2 sinclair sd224 antenna 200 ldf4-soa cable 4 n female connector 6 ground kit 2 hoisting grip 2 3' jumper 2 25' jumper 2 nemp polyphaser 1 installation hardware

Qty

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Road Department - One Chanel Description

PRIME SITE

SM,MLC8000 MOD

ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

ADD: 120/240VAC TO+ 12VDC POWER ADAPTER

ODER CREST

GTR 8000 BASE RADIO

ADD: VHF (136-174 MHZ) MID POWER

ADD: ANALOG CONVENTIONAL SOFTWARE

ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

ADD: RACK MOUNT HARDWARE

SM,MLC8000 MOD

ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

ADD: 120/240VAC TO +12VDC POWER ADAPTER

ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK

20 AMP BREAKER

HIGHLAND

GTR 8000 BASE RADIO

ADD: VHF (136-174 MHZ) MID POWER

ADD: ANALOG CONVENTIONAL SOFTWARE

ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

ADD: RACK MOUNT HARDWARE

SM,MLC8000 MOD

ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

ADD: 120/240VAC TO+ 12VDC POWER ADAPTER

ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK

20 AMP BREAKER

EU CHER

GTR 8000 BASE RADIO

ADD: VHF (136-174 MHZ) MID POWER

ADD: ANALOG CONVENTIONAL SOFTWARE

ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

ADD: RACK MOUNT HARDWARE

SM,MLC8000 MOD

ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

ADD: 120/240VAC TO +12VDC POWER ADAPTER

ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK

20 AMP BREAKER

Page 8: 4 N FEMALE CONNECTOR · 2 sinclair sd224 antenna 200 ldf4-soa cable 4 n female connector 6 ground kit 2 hoisting grip 2 3' jumper 2 25' jumper 2 nemp polyphaser 1 installation hardware

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

TABLE

GTR 8000 BASE RADIO

ADD: VHF {136-174 MHZ) MID POWER

ADD: ANALOG CONVENTIONAL SOFTWARE

ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

ADD: RACK MOUNT HARDWARE

SM,MLC8000 MOD

ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

ADD: 120/240VACTO +12VDC POWER ADAPTER

ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK

20 AMP BREAKER

PERPETUA

GTR 8000 BASE RADIO

ADD: VHF (136-174 MHZ) MID POWER

ADD: ANALOG CONVENTIONAL SOFTWARE

ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

ADD: RACK MOUNT HARDWARE

SM,MLC8000 MOD

ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

ADD: 120/240VACTO +12VDC POWER ADAPTER

20 AMP BREAKER

Page 9: 4 N FEMALE CONNECTOR · 2 sinclair sd224 antenna 200 ldf4-soa cable 4 n female connector 6 ground kit 2 hoisting grip 2 3' jumper 2 25' jumper 2 nemp polyphaser 1 installation hardware

.

Lincoln Fire Service - One Channel Expansion

Qty Description

PRIME SITE 1 SM,MLC8000 MOD

1 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY 1 ADD: 120/240VAC TO +12VDC POWER ADAPTER

OTTER CREST 1 GTR 8000 BASE RADIO

1 ADD: VHF (136-174 MHZ) MID POWER 1 ADD: ANALOG CONVENTIONAL SOFTWARE

1 ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

1 ADD: RACK MOUNT HARDWARE 1 SM,MLC8000 MOD 1 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY 1 ADD: 120/240VAC TO +12VDC POWER ADAPTER 1 ADD: 19INCH RACK MOUNT HARDWARE KIT CABINET OR RACK 1 20 AMP BREAKER

HIGHLAND 1 GTR 8000 BASE RADIO

1 ADD: VHF (136-174 MHZ) MID POWER 1 ADD: ANALOG CONVENTIONAL SOFTWARE

1 ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

1 ADD: RACK MOUNT HARDWARE 1 SM,MLC8000 MOD 1 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY 1 ADD: 120/240VAC TO +12VDC POWER ADAPTER 1 ADD: 19INCH RACK MOUNT HARDWARE KIT CABINET OR RACK 1 20 AMP BREAKER

EUCHER 1 GTR 8000 BASE RADIO

1 ADD: VHF (136-174 MHZ) MID POWER 1 ADD: ANALOG CONVENTIONAL SOFTWARE

1 ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

Page 10: 4 N FEMALE CONNECTOR · 2 sinclair sd224 antenna 200 ldf4-soa cable 4 n female connector 6 ground kit 2 hoisting grip 2 3' jumper 2 25' jumper 2 nemp polyphaser 1 installation hardware

1 ADD: RACK MOUNT HARDWARE 1 SM,MLC8000 MOD 1 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY 1 ADD: 120/240VAC TO +12VDC POWER ADAPTER 1 ADD: 19INCH RACK MOUNT HARDWARE KIT CABINET OR RACK 1 20 AMP BREAKER

TABLE 1 GTR 8000 BASE RADIO

1 ADD: VHF (136-174 MHZ) MID POWER 1 ADD: ANALOG CONVENTIONAL SOFTWARE

1 ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

1 ADD: RACK MOUNT HARDWARE 1 SM,MLC8000 MOD 1 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY 1 ADD: 120/240VAC TO +12VDC POWER ADAPTER 1 ADD: 19INCH RACK MOUNT HARDWARE KIT CABINET OR RACK 1 20 AMP BREAKER

PERPETUA 1 GTR 8000 BASE RADIO

1 ADD: VHF (136-174 MHZ) MID POWER 1 ADD: ANALOG CONVENTIONAL SOFTWARE

1 ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

1 ADD: RACK MOUNT HARDWARE 1 SM,MLC8000 MOD 1 ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY 1 ADD: 120/240VAC TO +12VDC POWER ADAPTER 1 20 AMP BREAKER

Page 11: 4 N FEMALE CONNECTOR · 2 sinclair sd224 antenna 200 ldf4-soa cable 4 n female connector 6 ground kit 2 hoisting grip 2 3' jumper 2 25' jumper 2 nemp polyphaser 1 installation hardware

SUBJECT: Simulcast Site Addition At Lincoln County Jail For Channels Law 1, Fire 1, Fire 2

EQUIPMENT 3 T7039 GTR 8000 BASE RADIO

3 X530BG ADD: VHF (136-174 MHZ) MID POWER

3 CA01949AA ADD: ANALOG CONVENTIONAL SOFTWARE

3 CA01952AA ADD: ANALOG CONVENTIONAL SIMULCAST SOFTWARE

3 X153AW ADD: RACK MOUNT HARDWARE

3 CA01400AA DC POWER CABLE

3 F2979 SM,MLC8000 MOD

3 VA00783AA ADD: ANALOG CONVENTIONAL SIMULCAST COMPARATOR/GATEWAY

3 VA00012AA ADD: 120/240VAC TO +12VDC POWER ADAPTER

3 VA00011AA ADD: 191NCH RACK MOUNT HARDWARE KIT CABINET OR RACK

1 413, 17 ,00,00,00,00,00 SPECTRACOM SECURESYNC TIMING 1 8225 SPECTRACOM GPS ANTENNA

1 8226 SPECTRACOM SURGE SUPPRESSOR

1 74-37-1 3279-E-R1 CUSTOM COMBINER/MULTICOUPLER, 3 CH

3 573351 SINCLAIR SD212 PIM RATED ANTENNA 1 COMBINER/MUL Tl COUPLER, 5 CH UPGRADE

350 429150 LDF4-50A CABLE

Page 1 of2

Page 12: 4 N FEMALE CONNECTOR · 2 sinclair sd224 antenna 200 ldf4-soa cable 4 n female connector 6 ground kit 2 hoisting grip 2 3' jumper 2 25' jumper 2 nemp polyphaser 1 installation hardware

3 337367 DIN FEMALE CONNECTOR

6 307423 DIN MALE CONNECTOR

18 313411 GROUND KIT

6 320023 HOISTING GRIP

1 362507 ENTRY BOOT

3 350367 POLYPHASER

1 62359 84" RACK

1 410585 -48VDC TO AC INVERTER

1 411166 RACK MOUNTED POWER STRIP

1 467311 NEWMAR POWER DISTRIBUTION PANEL

1 440000 20 AMP BREAKER

1 66443 5 AMP BREAKER

3 420098 30 AMP BREAKER

1 X430-24t EXTREME NETWORKS 24 PORT SWITCH

1 RB2011iL-RM ROUTER

EXD-180-002 DAC GE CARD

3 MISC INSTALLATION HARDWARE

9 Mount Antenna Mounting Hardware

45 Cable Hangers Cable Hangers to dress in the cable

3 Misc Hardware Misc Hardware for the installation

SERVICES

1 FCC LICENSING

1 ENGINEERING AND SYSTEM DESIGN

1 SYSTEM STAGING I PROGRAMMING I TESTING

1 INSTALLATION OF EQUIPMENT

1 INSTALLATION OF ANTENNA SYSTEM

1 ANTENNA SWEEP TESTING AND DOCUMENTATION

1 SYSTEM ALIGNMENT TO EXISTING INFRASTRUCTURE

1 SYSTEM OPTIMIZATION

1 ACCEPTANCE TESTING

1 SYSTEM DOCUMENTATION

Page 2 of2