40 hp vapor 900 psi 1993 - home | boyle services inc. hp...will ship with hydro, oklahoma odol...
TRANSCRIPT
Vapor Modulatic 40 HP, 900 PSI Steam Generator
Constructed in 1993 in strict accordance with ASME standards, stamped for 900 psi operation, once through watertube helical coil steam generator. Hour meter shows 67 hours total operation time. Vapor Power full modulation gas burner. Will ship with hydro, Oklahoma ODOL inspection certificate. All controls and safeties are UL/CSD-1 compliant. Valve shop package comes with: stainless
steel 100 gal feed tank & pump, 900 psi test drum, 900 psi steam accumulator, valve test muffler.
Input: 1,680,000 BTU
Gross Output: 1,340,000 BTU Steam Output: 1380 pounds per hour
MAWP: 900 psi Fuel: Natural gas
Equipment List:
Please reference photos and/or provided factory spec sheet.
Dimensions:
Please reference or request factory spec sheet for dimensions and connections
BOYLE SERVICES, INC.
701 W. 41st ST. TULSA, OK. 74107
1-800-772-6953 FAX: 918-446-1408
EMAIL: [email protected] www.boyleservices.com
551 S. County Line Rd. Franklin Park, IL 60131 P: 630.694.5500 F: 630.694.2230 VaporPower.com
Modulatic® Packaged Once-Through Steam Generators
SPECIFICATIONS 40 BHP
Power Requirements Main Power 230/460/575 VAC,
3 Ph, 60 Hz Control Power 120 VAC, 1 Ph, 60Hz HP required by pump 3 HP – for 300 psi HP required by blower 2 HP – for 300 psi
Overall Dimensions L x W x H 72” x 52” x 70” Performance Data Fuel Consumption @ Rated Output Gas 1,690 scfh Oil (No. 2) 11.9 gal/hr Turndown Ratios: Oil & Gas 8 to 1 Combustion and Ventilating Air Required: Oil & Gas 348 scfm
Customer Connections Stack Outlet 10” O.D. Steam Outlet
15 psi 4” ASA 300, 600 psi 1 1/2” NPT 900 psi 1 1/2” 600#
Main Gas Supply 2” NPT Pilot Gas Supply 1/2” NPT Oil Supply 3/4” NPT Oil Return 1/2” NPT Atomizing Air 3/8” NPT Feedwater Inlet 1” NPT Blowdown Outlet 1” NPT Coil Blowdown Outlet 1” NPT Water Pump Relief Valve 1/2” NPT Trap Return
15, 300, 600 psi 1/2” NPT 900 psi 3/4” NPT
Safety Valve Outlet 1 1/2” NPT -Note: varies based on set pressure
DESIGN DETAILS General Information Type of Boiler Watertube Model Series 4611 Rated Capacity 40 BHP Equivalent Evaporation 1,380 lb/hr from and at 212°F Thermal Output 1,340,000 Btu/hr Construction Codes ASME, Hartford,
National Board Boiler Shell Insulation Mineral Wool Insulation Approx. Shipping Weight 4,000 lbs
Pressure psig Design Operating 15 13 max. 300 250 max. 600 540 max. 900 810 max.
* Consult factory for pressures up to 3200 psig Controls Steam Pressure, Low Water Cutoff, Flame Failure Protection, Coil Temperature Limit. Burner Manufacturer Vapor Power Fuel Natural Gas, No. 2 Fuel Oil,
or Combination Type (gas) Multiple Orifice Nozzle Type (oil) Air Atomized Fuel Specifications: Oil (No. 2) 141,000 Btu/U.S. gal Gas 1000 Btu/cu ft Main Burner 1 psig Pilot Burner 6” W.C. Atomizing Air Requirements: Oil (No. 2) 5 scfm @ 40 psig Gas None required Ignition Type: Oil & Gas Electric spark - interrupted
gas pilot