400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 series

126
400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES, MODEL 648PRO, ICB648PRO and UC SERIES CONDENSED ELECTRONIC CONTROL INFORMATION BOOKLET NOTE: If more detailed information on the electronic controls is needed, the appropriate Service Manual must be referenced. Part #3756590 - Rev. G - April, 2007

Upload: others

Post on 25-May-2022

18 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

400 / 400-2 / 600 / 600-2 / 700 /

700-2 / 700-3 SERIES, MODEL

648PRO, ICB648PRO and

UC SERIES

CONDENSED

ELECTRONIC CONTROL

INFORMATION BOOKLET

NOTE: If more detailed information on theelectronic controls is needed, the appropriateService Manual must be referenced.

Part #3756590 - Rev. G - April, 2007

Page 2: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 2

400 Series (Wine) ................................... 5

Basic Input Operations ....................... 5Power ON/OFF - Adjust Set-Points -Lighting ON/OFF - Temp Alarm ON/OFF

Unique Input Operations ..................... 5Temp Units Selection Mode - SabbathMode - Showroom Mode

Error Indicators .................................... 6

Troubleshooting Input Operations ....... 7Diagnostic Mode - Valve Activation Mode -Temp. Log Recall Mode (Event Indicators)

400 Series (Model 427R Ref) ............... 12

Basic Input Operations ...................... 12Power ON/OFF - Adjust Set-Points -Drawer Ajar Alarm ON/OFF

Unique Input Operations .................... 12Temp Units Selection Mode - SabbathMode - Showroom Mode

Error Indicators .................................. 13

Troubleshooting Input Operations ..... 14Diagnostic Mode

400-2 Series (Wine) ............................... 16

Basic Input Operations ...................... 16Power ON/OFF - Adjust Set-Points -Lighting ON/OFF - Temp Alarm ON/OFF

Unique Input Operations .................... 16Temp Units Selection Mode - SabbathMode - Showroom Mode

Error Indicators .................................. 17

Troubleshooting Input Operations ..... 18Diagnostic Mode (Error Code Table) -Valve Activation Mode - Temp. Log RecallMode (Event Indicators)

400-2 Series (Model 427R-2 Ref) ......... 25

Basic Input Operations ...................... 25Power ON/OFF - Adjust Set-Points -Drawer Ajar Alarm ON/OFF

Unique Input Operations .................... 25Temp Units Selection Mode - SabbathMode - Showroom Mode

Error Indicators .................................. 26

Troubleshooting Input Operations ..... 27Diagnostic Mode (Error Code Table) -Valve Activation Mode - Temp. Log RecallMode (Event Indicators)

Service Input Operations ................... 33Auto and Manual Entry ModelConfiguration Mode (Model Code Table)

600 Series (PTS #1810000) .................. 36

Basic Input Operations ...................... 36Power ON/OFF - Adjust Set-Points - IMON/OFF

Unique Input Operations ................... 36Sabbath Mode - Showroom Mode -Manual Defrost

Error Indicators ................................. 37

Troubleshooting Input Operations ..... 38Diagnostic Mode

600 Series (SWS #1810000) ................. 41

Basic Input Operations ...................... 41Power ON/OFF - Adjust Set-Points - IMON/OFF - Door Ajar Alarm ON/OFF

Unique Input Operations ................... 42Temp Units Selection Mode - SabbathMode - Showroom Mode - CompartmentDisable Mode - Manual Defrost

Error Indicators ................................. 43

Troubleshooting Input Operations .... 44Diagnostic Mode (Error Code Table) -Component Activation Mode -Compartment Temp. Log Recall Mode -Compartment/Evap. Temp. Log Recall(Event Indicators)

PAGE

TABLE OF CONTENTS PAGE

Page 3: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 3

600-2 Series ........................................... 52

Basic Input Operations ..................... 52Power ON/OFF - Adjust Set-Points - IMON/OFF - Door Ajar Alarm ON/OFF

Unique Input Operations ................... 53Temp Units Selection Mode - SabbathMode - Showroom Mode - CompartmentDisable Mode - Manual Defrost

Error Indicators ................................. 54

Troubleshooting Input Operations ..... 55Diagnostic Mode (Error Code Table) -Component Activation Mode -Compartment Temp. Log Recall Mode -Compartment/Evap. Temp. Log Recall(Event Indicators)

700 Series .............................................. 63

Basic Input Operations ..................... 63Adjust Set-Points - Door Ajar AlarmON/OFF

Error Indicators ................................. 64

700-2 Series (Tall) ................................. 66

Basic Input Operations ..................... 66Power ON/OFF - Adjust Set-Points - IMON/OFF - Door Ajar Alarm ON/OFF

Unique Input Operations ................... 67Temp Units Selection Mode - SabbathMode - Showroom Mode - CompartmentDisable Mode - Manual Defrost

Error Indicators ................................. 68

Troubleshooting Input Operations ..... 69Diagnostic Mode (Error Code Table) -Component Activation Mode -Compartment Temp. Log Recall Mode -Compartment/Evap. Temp. Log Recall(Event Indicators)

PAGE PAGE

700-3 Series Tall Units .......................... 77

Basic Input Operations ..................... 77Power ON/OFF - Adjust Set-Points - IMON/OFF - Door Ajar Alarm ON/OFF

Unique Input Operations ................... 78Temp Units Selection Mode - SabbathMode - Showroom Mode - CompartmentDisable Mode - Manual Defrost

Error Indicators ................................. 79

Troubleshooting Input Operations ..... 80Diagnostic Mode (Error Code Table) -Component Activation Mode -Compartment Temp. Log Recall Mode -Compartment/Evap. Temp. Log Recall(Event Indicators)

700-2 Series (Base) .............................. 88

Basic Input Operations ..................... 88Power ON/OFF - Adjust Set-Points - IMON/OFF - Door Ajar Alarm ON/OFF

Unique Input Operations ................... 89Temp Units Selection Mode - SabbathMode - Showroom Mode - Manual Defrost

Error Indicators ................................. 90

Troubleshooting Input Operations ..... 91Diagnostic Mode

Page 4: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 4

700-3 Series Base Units ....................... 93

Basic Input Operations ..................... 93Power ON/OFF - Adjust Set-Points - IMON/OFF - Door Ajar Alarm ON/OFF

Unique Input Operations ................... 94Temp Units Selection Mode - SabbathMode - Showroom Mode - CompartmentDisable Mode - Manual Defrost

Error Indicators ................................. 95

Troubleshooting Input Operations ..... 96Diagnostic Mode (Error Code Table) -Component Activation Mode -Compartment Temp. Log Recall Mode -Compartment/Evap. Temp. Log Recall(Event Indicators)

Service Input Operations ................. 103Auto and Manual Entry ModelConfiguration Mode (Model Code Table)

Model 648PRO & ICB648PRO ............ 106

Basic Input Operations .................... 106Power ON/OFF - Adjust Set-Points - IMON/OFF - Door Ajar Alarm ON/OFF

Unique Input Operations ...................107Temp Units Selection Mode - SabbathMode - Showroom Mode - CompartmentDisable Mode - Manual Defrost

Error Indicators ................................ 108

Service Mode (Error Codes) ............ 109

PAGE PAGE

Undercounter Series ........................... 113

Basic Input Operations .................... 113Power ON/OFF - Adjust Set-Points

Unique Input Operations ........ 114Temp Units Selection Mode - SabbathMode - Showroom Mode - Manual Defrost

Error Indicators ................................ 115

Troubleshooting Input Operations ... 116Diagnostic Mode (Error Code Table) -Component Activation Mode -Compartment Temp. Log Recall Mode -Compartment/Evap. Temp. Log Recall(Event Indicators)

Service Input Operations ................. 123Auto and Manual Entry ModelConfiguration Mode (Model Code Table)

Page 5: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 5

400 SERIES WINE STORAGE

Basic Input Operations

» Power ON/OFF

- Press UNIT ON/OFF key

» Adjusting Set-Point (Temperature Adjust)- Press COLDER or WARMER keys of desired compartment

NOTE: Actual compartment temp. is displayed 10 seconds afterlast keystroke.

» Lighting System ON/OFF

- Press LIGHTS ON/OFF key

» Temperature Alarm ON/OFF

- Press Bell ON/OFF key

Unique Input Operations

» Temperature Units Selection Mode (°F or °C Display)- Within first minute of power up, press Bell ON/OFF key &

UNIT ON/OFF key simultaneously for 5 seconds

» Sabbath Mode (Disables lighting)1. Switch unit OFF

2. Press & hold UNIT ON/OFF key for 10 seconds

NOTE: To exit Sabbath Mode, repeat steps above.» Showroom Mode (Disables all but lighting)

1. Switch unit OFF

2. Press COLDER, WARMER & UNIT ON/OFF keys

simultaneously

NOTE: To exit Showroom Mode, repeat steps above.

Page 6: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 6

400 SERIES WINE STORAGE

Possible Error Indicators

NOTE: Temperatures shown are for reference only, actual tempera-tures may vary.

5555 SERVICE (Flashing) EEEEUpper compartment thermistor fault

BELL ON (Flashing)

5555 SERVICE (Flashing) EEEEUpper compartment thermistor fault with temperature alarm

EEEE SERVICE (Flashing) 5555Lower compartment thermistor fault

BELL ON (Flashing)EEEE SERVICE (Flashing) 5555Lower compartment thermistor fault with temperature alarm

5555 SERVICE (Flashing) 5555Either evaporator thermistor fault

BELL ON (Flashing)5555 SERVICE (Flashing) 5555Either evaporator thermistor fault with temperature alarm

NOTE: Cooling functions are disabled when error indicators appear.

Page 7: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 7

400 SERIES WINE STORAGE

Troubleshooting Input Operations

» Diagnostic Mode

1. Unit must be ON

2. Press either COLDER key & the UNIT ON/OFF key

simultaneously

NOTE: After performing the above key strokes, the followingwill appear on the display. Temperatures shown are for ref-erence only, actual temperatures may vary.

5500 SERVICE (Illuminated) UUEETemperature of UE (Upper Evaporator)

- Press COLDER key to toggle to next reading

4477 SERVICE (Illuminated) LLEETemperature of LE (Lower Evaporator)

- Press COLDER key to toggle to next reading

5555 SERVICE (Illuminated) UUPPTemperature of UP (Upper Compartment)

- Press COLDER key to toggle to next reading

5522 SERVICE (Illuminated) LLOOTemperature of LO (Lower Compartment)

NOTE: Diagnostic Mode will end 10 seconds after last keystroke. To observe temperatures longer than 10 seconds,press and hold UNIT ON/OFF key while in Diagnostic Mode.

Page 8: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 8

400 SERIES WINE STORAGE

» Valve Activation Mode (opens valve for 5 min.)1. Unit must be ON

2. Press and hold desired compartment COLDER

key and the UNIT ON/OFF key for 30 seconds

- If lower compartment COLDER key is chosen forabove key strokes, the following will appear on thedisplay. Temperatures shown are for reference only,actual temperatures may vary.

5511 SERVICE (Illuminated) LLEETemperature of LE (Lower Evaporator) displayed for 5 min.

- If upper compartment COLDER key is chosen forabove key strokes, the following will appear on theLED. Temperatures shown are for reference only,actual temperatures may vary.

4499 SERVICE (Illuminated) UUEETemperature of UE (Upper Evaporator) displayed for 5 min.

NOTE: Valve Activation Mode will end after 5 minutes.To exit before the full 5 minutes, press the UNIT ON/OFFkey to switch the unit OFF, then again to switch it backON.

Page 9: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 9

400 SERIES WINE STORAGE

» Temperature Log Recall Mode

1. Unit must be ON

2. Press and hold desired compartment WARMER

key and the UNIT ON/OFF, then release both keys

NOTE: After performing the above key strokes, the fol-lowing will appear on the display. Temperatures shownare for reference only, actual temperatures may vary.

5533 SERVICE (Illuminated) 114 hour compartment temperature average (at left) with

index number. Number 1 is most recent 4 hour period.

NOTE: SERVICE is always illuminated at first index.

- Press WARMER key in multiple keystrokes to toggle

up through indexes, from 1 to 64.

6600 66444 hour compartment temperature average (at left) with

index number. Number 64 is oldest recorded 4 hour period.

- Press COLDER key in multiple keystrokes to toggle

down through indexes, from 64 to 1.

NOTE: See following page for possible event indicatorsduring Temperature Log Recall Mode. Temperature LogRecall Mode will end 10-15 seconds after last key stroke.

Page 10: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 10

400 SERIES WINE STORAGE

Possible Event Indicators During Temperature Log Recall

BELL ON (Illuminated)6666 22BELL ON Illuminated indicates power failure/interruption.

6688 SERVICE (Illuminated) 2299SERVICE illuminated indicates unit was switched off with

UNIT ON/OFF key

-- -- -- --Double Dashes (-- -- ) displayed indicates electronic control

board is bad. Control board must be replaced.

NOTE: Temperature Log Recall Mode will end 10-15seconds after last key stroke.

Page 11: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 11

400 SERIES WINE STORAGE NOTES

Page 12: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 12

400 SERIES, MODEL 427R REFRIGERATOR

Basic Input Operations

» Power ON/OFF

- Press UNIT ON/OFF key

» Adjusting Set-Point (Temperature Adjust)- Press COLDER or WARMER key

NOTE: Actual compartment temp. is displayed 10 secondsafter last keystroke.

» Drawer Ajar Alarm ON/OFF

- Press Alarm ON/OFF key

Unique Input Operations

» Temperature Units Selection Mode (°F or °C Display)- Within first minute of power up, press Alarm ON/OFF

key & UNIT ON/OFF key simultaneously

» Sabbath Mode (Disables lighting)1. Switch unit OFF

2. Press & hold UNIT ON/OFF key for 10 seconds

NOTE: To exit Sabbath Mode, repeat steps above.» Showroom Mode (Disables all but lighting)

1. Switch unit OFF

2. Press COLDER, WARMER & UNIT ON/OFF keys simul-

taneously

NOTE: To exit Showroom Mode, repeat steps above.

Page 13: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 13

400 SERIES, MODEL 427R REFRIGERATOR

Possible Error Indicators

NOTE: Temperature shown is for reference only, actual tem-perature may vary.

TOP DRAWER (Flashing)EEEE LOWER DRAWER (Flashing)Refrigerator compartment thermistor fault

TOP DRAWER (Flashing)

4400 LOWER DRAWER (Flashing)Refrigerator evaporator thermistor fault.

EE00700BR & 700BF Communication Error between

Control Board & Control Panel

EE33700BR & 700BF Communication Error between

Control Board & Control Panel

Page 14: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 14

400 SERIES, MODEL 427R REFRIGERATOR

Troubleshooting Input Operations

» Diagnostic Mode

1. Unit must be ON

2. Press COLDER & UNIT ON/OFF keys simultaneously,

then release both keys

NOTE: After performing the above key strokes, the followingwill appear on the LCD. Temperatures shown are for refer-ence only, actual temperatures may vary.

3388First reading is refrigerator compartment temperature.

rPress UNIT ON/OFF key while in Diagnostic Mode to dis-

play location. (r = Refrigerator Compartment)

3344Press COLDER key. Second reading is evaporator Temp.

EEPress UNIT ON/OFF key while in Diagnostic Mode to dis-

play location. (E = Evaporator)

EEEEIf “EE” is displayed in place of temperature, thermistor is faulty.

NOTE: Diagnostic Mode ends 10 seconds after last keystroke.

Page 15: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 15

400 SERIES, MDL 427R REFRIG NOTES

Page 16: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 16

400-2 SERIES WINE STORAGE

Basic Input Operations

» Power ON/OFF

- Press UNIT ON/OFF key

» Adjusting Set-Point (Temperature Adjust)- Press COLDER or WARMER keys of desired compartment

NOTE: Actual compartment temp. is displayed 10 seconds afterlast keystroke.

» Lighting System ON/OFF

- Press LIGHTS ON/OFF key

» Temperature Alarm ON/OFF

- Press Bell ON/OFF key

Unique Input Operations

» Temperature Units Selection Mode (°F or °C Display)- Within first minute of power up, press Bell ON/OFF key &

UNIT ON/OFF key simultaneously for 5 seconds

» Sabbath Mode (Disables lighting)1. Switch unit OFF

2. Press & hold UNIT ON/OFF key for 10 seconds

NOTE: To exit Sabbath Mode, press UNIT ON/OFF.» Showroom Mode (Disables all but lighting)

1. Switch unit OFF

2. Press COLDER, WARMER & UNIT ON/OFF keys

simultaneously

NOTE: To exit Showroom Mode, repeat steps above.

Page 17: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 17

400-2 SERIES WINE STORAGE

Possible Error Indicators

NOTE: Temperatures shown are for reference only, actual tempera-tures may vary.

5555 SERVICE (Flashing) EEEEUpper compartment thermistor fault

BELL ON (Flashing)

5555 SERVICE (Flashing) EEEEUpper compartment thermistor fault with temperature alarm

EEEE SERVICE (Flashing) 5555Lower compartment thermistor fault

BELL ON (Flashing)EEEE SERVICE (Flashing) 5555Lower compartment thermistor fault with temperature alarm

5555 SERVICE (Flashing) 5555Either evaporator thermistor fault

BELL ON (Flashing)5555 SERVICE (Flashing) 5555Either evaporator thermistor fault with temperature alarm

NOTE: Cooling functions are disabled when error indicators appear.

Page 18: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 18

400-2 SERIES WINE STORAGE

Troubleshooting Input Operations

» Diagnostic Mode

1. Unit must be ON

2. Press COLDER & UNIT ON/OFF keys simultaneously, then

release both keys

NOTE: After performing the above key strokes, the following willappear on the display. Temperatures shown are for refer-ence only, actual temperatures may vary.

5500 SERVICE (Illuminated) UUEETemperature of Upper Evaporator

- Press COLDER key to toggle to next reading

4477 SERVICE (Illuminated) LLEETemperature of Lower Evaporator

- Press COLDER key to toggle to next reading

5555 SERVICE (Illuminated) UUPPTemperature of Upper Compartment

- Press COLDER key to toggle to next reading

5522 SERVICE (Illuminated) LLOOTemperature of Lower Compartment

- Pressing the COLDER key at this time will take the display

back to the first reading.

(CONTINUED)

Page 19: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 19

400-2 SERIES WINE STORAGE

(CONTINUED)

NOTE: If “EECC” (Error Code) is displayed, see ErrorCode Table on next page.

NOTE: If “EEEE” is displayed in place of temperature,thermistor in that location is faulty.

NOTE: Diagnostic Mode will end 10 seconds afterlast key stroke.

Page 20: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 20

ERROR CODE TABLE

CODE INDICATION

05 Upper Cabinet Thermistor read open / short for 10+

seconds, or repeatedly erratic temp’s.

06 Upper Evap. Thermistor read open / short for 10+

seconds, or repeatedly erratic temp’s.

07 Lower Cabinet Thermistor read open / short for 10+

seconds, or repeatedly erratic temp’s.

08 Lower Evap. Thermistor read open / short for 10+

seconds, or repeatedly erratic temp’s.

10 Upper Cabinet Warm Temperature alarm

11 Upper Cabinet Cold Temperature alarm

12 Lower Cabinet Warm Temperature alarm

13 Lower Cabinet Cold Temperature alarm

15 Sealed System Fault (evap temp. cannot drop 5° in

5 minutes, 3 consecutive valve activations)

400-2 SERIES WINE STORAGE

NOTE: To clear Error Codes, see next page.

Page 21: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 21

400-2 SERIES WINE STORAGE

» Clearing Error Codes

1. Unit must be ON and problem repaired

2. Press and hold Bell ON/OFF key for 15 seconds

» Manual Valve Activation Mode

(Energizes cooling system for 5 minutes)

1. Unit must be ON

2. Press desired COLDER & UNIT ON/OFF keys simul-

taneously for 10 seconds

NOTE: After performing the above key strokes (depend-ing on COLDER key chosen), the following will appear onthe LCD. Temperatures shown are for reference only,actual temperatures may vary.

5511 SERVICE (Illuminated) LLEETemperature of Lower Evaporator

OR5511 SERVICE (Illuminated) UUEETemperature of Upper Evaporator

Page 22: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 22

400-2 SERIES WINE STORAGE » Temperature Log Recall Mode

(Compartment Temperature History Only)

1. Unit must be ON

2. Press desired WARMER & UNIT ON/OFF keys simultane-

ously, then release both keys

NOTE: After performing the above key strokes (depending onCOLDER key chosen), the following will appear on the display.Temperatures shown are for reference only, actual temperaturesmay vary.

5533 SERVICE (Illuminated) 114 hour compartment temperature average (at left) with

index number. Number 1 is most recent 4 hour period.

NOTE: SERVICE is always illuminated at first index.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 64.

6600 66444 hour compartment temperature average (at left) with

index number. Number 64 is oldest recorded 4 hour period.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 64 to 1.

NOTE: See following page for possible event indicators duringTemperature Log Recall Mode. Temperature Log Recall Modewill end 10-15 seconds after last key stroke.

Page 23: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 23

400-2 SERIES WINE STORAGE

Possible Event Indicators During Temperature Log Recall

BELL ON (Illuminated)6666 22BELL ON Illuminated indicates power failure/interruption.

6688 SERVICE (Illuminated) 2299SERVICE illuminated indicates unit was switched off with

UNIT ON/OFF key

-- -- -- --Double Dashes (- - ) displayed indicates electronic control

board is bad. Control board must be replaced.

NOTE: Temperature Log Recall Mode will end 10-15 secondsafter last key stroke.

Page 24: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 24

400-2 SERIES WINE STORAGE NOTES

Page 25: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 25

400-2 SERIES - 427R-2 REFRIGERATOR

Basic Input Operations

» Power ON/OFF

- Press UNIT ON/OFF key

» Adjusting Set-Point (Temperature Adjust)- Press COLDER or WARMER key

NOTE: Actual compartment temp. is displayed 10 secondsafter last keystroke.

» Drawer Ajar Alarm ON/OFF

- Press Alarm ON/OFF key

Unique Input Operations

» Temperature Units Selection Mode (°F or °C Display)- Within first minute of power up, press Alarm ON/OFF

key & UNIT ON/OFF key simultaneously

» Sabbath Mode (Disables lighting)1. Switch unit OFF

2. Press & hold UNIT ON/OFF key for 10 seconds

NOTE: To exit Sabbath Mode, press UNIT ON/OFF key.» Showroom Mode (Disables all but lighting)

1. Switch unit OFF

2. Press COLDER, WARMER & UNIT ON/OFF keys simul-

taneously

NOTE: To exit Showroom Mode, repeat steps above.

Page 26: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 26

400-2 SERIES - 427R-2 REFRIGERATOR

Possible Error Indicators

NOTE: Temperatures shown are for reference only, actual tempera-tures may vary.

EEEE SERVICE (Flashing)Refrigerator compartment thermistor fault

3388 SERVICE (Flashing)Several excessive compressor run periods OR

Refrigerator evaporator thermistor fault

3388 SERVICE (Steady, not Flashing)Error Codes logged and observed but not cleared.

- -

Several consecutive Double Dashes (- -) displayed indi-

cates electronic control board is bad. Control board must

be replaced.

NOTE: To clear Error Indicators, repair problem then switch unitOFF and back ON. To clear Error Codes, press bell ON/OFF keyfor 15 seconds.

Page 27: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 27

400-2 SERIES - 427R-2 REFRIGERATOR

Troubleshooting Input Operations

» Diagnostic Mode

1. Unit must be ON

2. Press COLDER & UNIT ON/OFF keys simultaneously, then

release both keys

NOTE: After performing the above key strokes, the following willappear on the LCD. Temperatures shown are for referenceonly, actual temperatures may vary.

4400 SERVICE (Illuminated) rTemperature of r (Refrigerator Compartment)

- Press COLDER key to toggle to next reading

3322 SERVICE (Illuminated) EETemperature of E (Evaporator)

- Pressing the COLDER key at this time will take display

back to first reading.

(CONTINUED)

Page 28: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 28

400-2 SERIES - 427R-2 REFRIGERATOR

(CONTINUED)

NOTE: If “EECC” (Error Code) is displayed, see ErrorCode Table below.

NOTE: If “EEEE” is displayed in place of temperature,thermistor in that location is faulty.

NOTE: If “SSr” is displayed in place of temperature,unit is in Showroom Mode.

NOTE: Diagnostic Mode will end 20 seconds afterlast key stroke.

ERROR CODE TABLE

CODE INDICATION

05 Upper Cabinet Thermistor read open / short for 10+

seconds, or repeatedly erratic temp’s.

06 Upper Evap. Thermistor read open / short for 10+

seconds, or repeatedly erratic temp’s.

50 Excessive Refrigerator compressor run

NOTE: To clear Error Codes, see next page.

Page 29: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 29

400-2 SERIES - 427R-2 REFRIGERATOR

» Clearing Error Codes

1. Unit must be ON

2. Repair problem

3. Press and hold Bell ON/OFF key for 15 seconds

» Manual Component Activation Mode

(Energizes cooling system for 5 minutes)

1. Unit must be ON

2. Press COLDER & UNIT ON/OFF keys simultaneously for

10 seconds

NOTE: After performing the above key strokes, the following willappear on the LCD. Temperatures shown are for reference only,actual temperatures may vary.

2299 SERVICE (Illuminated) EETemperature of E (Refrigerator Evaporator)

Page 30: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 30

400-2 SERIES - 427R-2 REFRIGERATOR» Temperature Log Recall Mode

(Compartment Temperature History Only)

1. Unit must be ON

2. Press WARMER & UNIT ON/OFF keys simultaneously,

then release both keys

NOTE: After performing the above key strokes, the following willappear on the LCD. Temperatures shown are for reference only,actual temperatures may vary.

3388 SERVICE (Illuminated) 112 hour compartment temperature average (at left) with

index number. Number 1 is most recent 2 hour period.

NOTE: SERVICE is always illuminated at first index.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 168.

3366 1166882 hour compartment temperature average (at left) with

index number. Number 168 is oldest recorded 2 hour peri-

od.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 168 to 1.

NOTE: Possible event indicators during Temperature Log RecallMode is covered later. Temperature Log Recall Mode ends 15seconds after last key stroke.

Page 31: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 31

400-2 SERIES - 427R-2 REFRIGERATOR» Temperature Log Recall Mode

(Compartment &/or Evaporator temperature History)

1. With unit on, initiate Diagnostic Mode - Press COLDER key

& UNIT ON/OFF keys simultaneously, then release.

2. Toggle through temperature readings by pressing COLDER

or WARMER key until desired thermistor temperature is

observed

3. Press WARMER key for that compartment and UNIT

ON/OFF simultaneously

NOTE: After performing the above key strokes, the following willappear on the LCD. Temperatures shown are for reference only,actual temperatures may vary.

3300 SERVICE (Illuminated) 112 hour thermistor temperature average (at left) with index

number. Number 1 is most recent 2 hour period.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 168.

2288 1166882 hour thermistor temperature average (at left) with index

number. Number 168 is oldest recorded 2 hour period.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 168 to 1.

NOTE: Possible event indicators during Temperature Log RecallMode are on next page. Temperature Log Recall Mode ends 15seconds after last key stroke.

Page 32: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 32

400-2 SERIES - 427R-2 REFRIGERATOR

Possible Event Indicators During Temperature Log Recall

bl 110077“bl” indicates index is blank, no temperature recorded yet

3366 SERVICE (Illuminated) 8899SERVICE illuminated indicates unit was switched off with

UNIT ON/OFF key

Bell (Illuminated)3388 110055BELL Illuminated indicates power failure/interruption.

- - 2288

Several consecutive Double Dashes (- -) displayed indi-

cates electronic control board is bad. Control board must

be replaced.

NOTE: Temperature Log Recall Mode will end 15 secondsafter last key stroke.

NOTE: Temperatures continue to be logged when unit isswitched off with UNIT ON/OFF key and when ShowroomMode or Manual Compartment Disable Mode is initiated.

Page 33: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 33

400-2 SERIES - 427R-2 REFRIGERATORService Input Operations

» Auto Model Configuration Mode

If a new main control board is installed during a service call,

double dashes ( - - ) will appear on the LCD indicating the board

must be configured for the model it was installed into.

1. Open bottom drawer.

2. With unit on - Press COLDER or WARMER key to toggle

through model codes, then stop when proper code is dis-

played (See Model Code Table on next page).

3. Press UNIT ON/OFF key to store configuration.

» Manual Entry Model Configuration Mode

If control board configuration needs to be verified or changed:

1. Open bottom drawer.

2. With unit on - Press COLDER and UNIT ON/OFF keys

simultaneously, then release.

3. Press Bell ON/OFF and UNIT ON/OFF keys simultaneous-

ly, then release.

4. Press COLDER or WARMER key to toggle through model

codes, then stop when proper code is displayed (See

Model Code Table on next page).

3. Press UNIT ON/OFF key to store configuration.

Page 34: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 34

400-2 SERIES - 427R-2 REFRIGERATOR

br 700BR

bC 700BC

27 427R

bF 700BFI

2r UC-24R / UC-24RO

2C UC-24C

2b UC-24B

MODEL CODE TABLE

CODE MODEL

Page 35: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 35

400-2 SERIES NOTES

Page 36: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 36

600 SERIES (Prior To Serial #1810000)

Basic Input Operations

» Power ON/OFF

- Press UNIT ON/OFF key

» Adjusting Set-Point (Temperature Adjust)- Press COLDER or WARMER keys of desired compart-

ment

NOTE: Actual compartment temp. is displayed 10 secondsafter last keystroke.

» Icemaker ON/OFF

- Press ICE ON/OFF key (“ICE” appears on LCD)

Unique Input Operations

» Sabbath Mode (Disables lighting)1. Switch unit OFF

2. Press & hold UNIT ON/OFF key for 10 seconds

NOTE: To exit Sabbath Mode, repeat steps above.» Showroom Mode (Disables all but lighting)

1. Switch unit OFF

2. Press COLDER, WARMER & UNIT ON/OFF keys

simultaneously

NOTE: To exit Showroom Mode, repeat steps above.» Manual Defrost

- Press & hold ICE ON/OFF key for 5 seconds.

Page 37: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 37

600 SERIES (Prior To Serial #1810000)

Possible Error Indicators

NOTE: Temperatures shown are for reference only, actual tempera-tures may vary.

EEEE SERVICE (Flashing) 3388Freezer compartment thermistor Fault

0000 SERVICE (Flashing) EEEERefrigerator compartment thermistor fault

0000 SERVICE (Flashing) 3388Refrigerator evaporator thermistor fault

SERVICE (Flashing)

0000 ICE (Flashing) 3388Water valve energized longer than 15 seconds. Icemaker

system disabled.

NOTE: A 45 minute dwell follows each IM cycles (no powerto Icemaker). To bypass 45 minute dwell, Switch unit OFFthen back ON.

SERVICE (Flashing)

1122 VACUUM (Flashing) 4455CONDENSER

Several excessive compressor run periods

NOTE:To clear Error Indicators, repair problem then switch unitOFF and back ON.

Page 38: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 38

600 SERIES (Prior To Serial #1810000)Troubleshooting Input Operations

» Diagnostic Mode

1. Unit must be ON

2. Press COLDER & UNIT ON/OFF keys simultaneously, then

release both keys

NOTE: After performing the above key strokes, the following willappear on the LCD. Temperatures shown are for reference only,actual temperatures may vary.

00 SERVICE (Illuminated)First reading is freezer compartment temperature.

FF SERVICE (Illuminated)

- Press UNIT ON/OFF key to display location code.

(FF = Freezer Compartment)3388 SERVICE (Illuminated)

- Press COLDER key. Second reading is refrigerator com-

partment temperature.

r SERVICE (Illuminated)

- Press UNIT ON/OFF key to display location code.

(r = Refrigerator Compartment)1155 SERVICE (Illuminated)

- Press COLDER key. Third reading is refrigerator evapora-

tor temperature.

rEE SERVICE (Illuminated)

- Press UNIT ON/OFF key to display location code.

(rEE = Refrigerator Evaporator) (CONTINUED)

Page 39: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 39

600 SERIES (Prior To Serial #1810000)(CONTINUED)

--1100 SERVICE (Illuminated)- Press COLDER key. Fourth reading is freezer evaporator

temperature.

FFEE SERVICE (Illuminated)

- Press UNIT ON/OFF key to display location code.

(FF = Freezer Compartment)0000 SERVICE (Illuminated)

- Press COLDER key. Fifth reading is inactive line, no tem-

perature.

iiLL SERVICE (Illuminated)

- Press UNIT ON/OFF key to display location code.

(iiLL = Inactive Line, Disregard)

- Pressing the COLDER key at this time will take the display

back to the first reading, the freezer compartment tempera-

ture.

NOTE: It is possible to toggle through the temperaturereadings by pressing the COLDER key without the stepsof pressing the UNIT ON/OFF key.

NOTE: If “EEEE ” appears instead of a temperature, pressUNIT ON/OFF key to determine which thermistor is faulty.NOTE: Diagnostic Mode will end 10 seconds after last keystroke.

Page 40: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 40

600 SERIES (PTS #1810000) NOTES

Page 41: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 41

600 SERIES (Starting With Serial #1810000)

Basic Input Operations

» Power ON/OFF

- Press UNIT ON/OFF key

» Adjusting Set-Point (Temperature Adjust)- Press COLDER or WARMER keys of desired com-

partment

NOTE: Actual compartment temp. is displayed 10 sec-onds after last keystroke.

» Icemaker ON/OFF

- Press ICE ON/OFF key

» Door Ajar Alarm ON/OFF

- Press Bell ON/OFF key

Page 42: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 42

600 SERIES (Starting With Serial #1810000)

Unique Input Operations

» Temperature Units Selection Mode (°F or °C Display)- Within first minute of power up, press Bell ON/OFF key

& UNIT ON/OFF key simultaneously for 5 seconds

» Sabbath Mode (Disables lighting)1. Switch unit OFF

2. Press & hold UNIT ON/OFF key for 10 seconds

NOTE: To exit Sabbath Mode, repeat steps above.» Showroom Mode (Disables all but lighting)

1. Switch unit OFF

2. Press COLDER, WARMER & UNIT ON/OFF keys

simultaneously

NOTE: To exit Showroom Mode, repeat steps above.» Compartment Disable Mode (Disables compartment cool-

ing, “- -” appears on LCD)1. Switch unit OFF

2. Press desired WARMER & UNIT ON/OFF keys simulta-

neously

NOTE: To return to normal operation, repeat steps above.» Manual Defrost

- Press & hold ICE ON/OFF key for 5 seconds.

Page 43: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 43

600 SERIES (Starting With Serial #1810000)

Possible Error Indicators

NOTE: Temperatures shown are for reference only, actual tempera-tures may vary.

EEEE SERVICE (Flashing) 3388Freezer compartment thermistor fault

0000 SERVICE (Flashing) EEEERefrigerator compartment thermistor fault

0000 SERVICE (Flashing) 3388Several excessive compressor run periods OR

Refrigerator evaporator thermistor fault

SERVICE (Flashing)

0000 ICE (Flashing) 3388Water valve energized longer than 15 seconds. Icemaker

system disabled.

NOTE: A 45 minute dwell follows each IM cycles (no powerto Icemaker). To bypass 45 minute dwell, Switch unit OFFthen back ON.

NOTE: To clear Error Indicators, repair problem then switch unitOFF and back ON.

Page 44: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 44

600 SERIES (Starting With Serial #1810000)

Troubleshooting Input Operations

» Diagnostic Mode

1. Unit must be ON

2. Press COLDER & UNIT ON/OFF keys simultaneously, then

release both keys

NOTE: After performing the above key strokes, the following willappear on the LCD. Temperatures shown are for referenceonly, actual temperatures may vary.

--0055 SERVICE (Illuminated) FFTemperature of F (Freezer Compartment)

- Press COLDER key to toggle to next reading

4400 SERVICE (Illuminated) rTemperature of r (Refrigerator Compartment)

- Press COLDER key to toggle to next reading

--1122 SERVICE (Illuminated) FFEETemperature of FE (Freezer Evaporator)

- Press COLDER key to toggle to next reading

2299 SERVICE (Illuminated) rEETemperature of rE (Refrigerator Evaporator)

- Pressing the COLDER key at this time will take the display

back to the first reading, the freezer compartment tempera-

ture.

(CONTINUED)

Page 45: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 45

600 SERIES (Starting With Serial #1810000)

(CONTINUED)

NOTE: If “EECC” (Error Code) is displayed, see ErrorCode Table on next page.

NOTE: If “EEEE” is displayed in place of temperature,thermistor in that location is faulty.

NOTE: If “SSr” is displayed in place of temperature,unit is in Showroom Mode.

NOTE: Diagnostic Mode will end 10 seconds afterlast key stroke.

Page 46: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 46

Error Code Table

CODE INDICATION

05 Refrig. Cabinet Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s

06 Refrig. Evaporator Thermistor read open or shorted for10+ seconds, or repeatedly read erratic temp’s

07 Freezer Cabinet Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s

08 Freezer Evaporator Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s

20 Defrost Underheat with No Voltage Feedback Through Gray/White Wire at Defrost Start

21 Defrost Overheat22 No Voltage Feedback Through Gray/White Wire at

Defrost Start23 Defrost Overheat with No Voltage Feedback through

Gray/White Wire at Defrost Start24 Defrost Underheat

600 SERIES (Starting With Serial #1810000)

NOTE: Currently, Error Codes are registered because of thermistoror defrost system errors only. The table above will be updatedthrough addendums when subsequent software and electricalchanges occur and more error codes are added.

To clear Error Codes, see next page.

Page 47: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 47

600 SERIES (Starting With Serial #1810000)

» Clearing Error Codes

1. Unit must be ON

2. Repair problem

3. Press and hold Bell ON/OFF key for 15 seconds

» Manual Component Activation Mode

(Energizes cooling system for 5 minutes)

1. Unit must be ON

2. Press desired COLDER & UNIT ON/OFF keys simultane-

ously for 10 seconds

NOTE: After performing the above key strokes (depending onCOLDER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

--1188 SERVICE (Illuminated) FFEETemperature of F (Freezer Evaporator)

OR2299 SERVICE (Illuminated) rEETemperature of rE (Refrigerator Evaporator)

Page 48: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 48

600 SERIES (Starting With Serial #1810000)» Temperature Log Recall Mode

(Compartment Temperature History Only)

1. Unit must be ON

2. Press desired WARMER & UNIT ON/OFF keys simultane-

ously, then release both keys

NOTE: After performing the above key strokes (depending onCOLDER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

3388 SERVICE (Illuminated) 00112 hour compartment temperature average (at left) with

index number. Number 1 is most recent 2 hour period.

NOTE: SERVICE is always illuminated at first index.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 168.

3366 1166882 hour compartment temperature average (at left) with

index number. Number 168 is oldest recorded 2 hour peri-

od.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 168 to 1.

NOTE: Possible event indicators during Temperature Log RecallMode is covered later. Temperature Log Recall Mode ends 15seconds after last key stroke.

Page 49: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 49

600 SERIES (Starting With Serial #1810000)» Temperature Log Recall Mode

(Compartment &/or Evaporator temperature History)

1. With unit on, initiate Diagnostic Mode - Press either COLD-

ER key & UNIT ON/OFF keys simultaneously, then release.

2. Toggle through temperature readings by pressing COLDER

or WARMER key until desired thermistor temperature is

observed

3. Press WARMER key for that compartment and UNIT

ON/OFF simultaneously

NOTE: After performing the above key strokes (depending onWARMER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

--1100 SERVICE (Illuminated) 00112 hour thermistor temperature average (at left) with index

number. Number 1 is most recent 2 hour period.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 168.

--1122 1166882 hour thermistor temperature average (at left) with index

number. Number 168 is oldest recorded 2 hour period.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 168 to 1.

NOTE: Possible event indicators during Temperature Log RecallMode is on next page. Temperature Log Recall Mode ends 15seconds after last key stroke.

Page 50: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 50

600 SERIES (Starting With Serial #1810000)

Possible Event Indicators During Temperature Log Recall

bl 110077“bl” indicates index is blank, no temperature recorded yet

3366 SERVICE (Illuminated) 8899SERVICE illuminated indicates unit was switched off with

UNIT ON/OFF key

Bell (Illuminated)3388 110055BELL Illuminated indicates power failure/interruption.

- - 2288

Several consecutive Double Dashes (- -) displayed indi-

cates electronic control board is bad. Control board must

be replaced.

NOTE: Temperature Log Recall Mode will end 10 secondsafter last key stroke.

NOTE: Temperatures continue to be logged when unit isswitched off with UNIT ON/OFF key and when ShowroomMode or Manual Compartment Disable Mode is initiated.

Page 51: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 51

600 SERIES (SWS #1810000) NOTES

Page 52: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 52

600-2 SERIES

Basic Input Operations

» Power ON/OFF

- Press UNIT ON/OFF key

» Adjusting Set-Point (Temperature Adjust)- Press COLDER or WARMER keys of desired com-

partment

NOTE: Actual compartment temp. is displayed 10 sec-onds after last keystroke.

» Icemaker ON/OFF

- Press ICE ON/OFF key

» Door Ajar Alarm ON/OFF

- Press Bell ON/OFF key

Page 53: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 53

600-2 SERIES

Unique Input Operations

» Temperature Units Selection Mode (°F or °C Display)- Within first minute of power up, press Bell ON/OFF key

& UNIT ON/OFF key simultaneously for 5 seconds

» Sabbath Mode (Disables lighting)1. Switch unit OFF

2. Press & hold UNIT ON/OFF key for 10 seconds

NOTE: To exit Sabbath Mode, press UNIT ON/OFF Key.» Showroom Mode (Disables all but lighting)

1. Switch unit OFF

2. Press COLDER, WARMER & UNIT ON/OFF keys

simultaneously

NOTE: To exit Showroom Mode, repeat steps above.» Compartment Disable Mode (Disables compartment cool-

ing, “- -” appears on LCD)1. Switch unit OFF

2. Press desired WARMER & UNIT ON/OFF keys simulta-

neously

NOTE: To return to normal operation, repeat steps above.» Manual Defrost

- Press & hold ICE ON/OFF key for 5 seconds.

Page 54: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 54

600-2 SERIES

Possible Error Indicators

NOTE: Temperatures shown are for reference only, actual tempera-tures may vary.

EEEE SERVICE (Flashing) 3388Freezer compartment thermistor fault

0000 SERVICE (Flashing) EEEERefrigerator compartment thermistor fault

0000 SERVICE (Flashing) 3388Several excessive compressor run periods OR

Refrigerator evaporator thermistor fault

SERVICE (Flashing)

0000 ICE (Flashing) 3388Water valve energized longer than 15 seconds, five consec-

utive times. Icemaker system disabled 24 hours each time.

NOTE: A 45 minute dwell follows each IM cycles (no powerto Icemaker). To bypass 45 minute dwell, Switch ice makersystem OFF then back ON.

0000 SERVICE (Steady, not Flashing)3388Error Codes logged and observed but not cleared.

NOTE: To clear Error Codes, press bell ON/OFF key for 15 sec-onds.

Page 55: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 55

600-2 SERIES

Troubleshooting Input Operations

» Diagnostic Mode

1. Unit must be ON

2. Press COLDER & UNIT ON/OFF keys simultaneously, then

release both keys

NOTE: After performing the above key strokes, the following willappear on the LCD. Temperatures shown are for referenceonly, actual temperatures may vary.

--0055 SERVICE (Illuminated) FFTemperature of F (Freezer Compartment)

- Press COLDER key to toggle to next reading

4400 SERVICE (Illuminated) rTemperature of r (Refrigerator Compartment)

- Press COLDER key to toggle to next reading

--1122 SERVICE (Illuminated) FFEETemperature of FE (Freezer Evaporator)

- Press COLDER key to toggle to next reading

2299 SERVICE (Illuminated) rEETemperature of rE (Refrigerator Evaporator)

- Pressing the COLDER key at this time will take the display

back to the first reading, the freezer compartment tempera-

ture.

(CONTINUED)

Page 56: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 56

600-2 SERIES(CONTINUED)

NOTE: If “EECC” (Error Code) is displayed, see Error CodeTable below.

NOTE: If “EEEE” is displayed in place of temperature, ther-mistor in that location is faulty.

NOTE: If “SSr” is displayed in place of temperature, unit isin Showroom Mode.

NOTE: Diagnostic Mode will end 10 seconds after lastkey stroke.

NOTE: To clear Error Indicators, repair problem then switch unitOFF and back ON. To clear Error Codes, press bell ON/OFF keyfor 15 seconds.

Page 57: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 57

Error Code Table

CODE INDICATION

05 Ref. cabinet therm. read open, short or erratic temp for 10+ sec’s06 Ref. evap. therm. read open, short or erratic temp for 10+ sec’s07 Fre. cabinet therm. read open, short or erratic temp for 10+ sec’s08 Fre. evap. therm. read open, short or erratic temp for 10+ sec’s20 Defrost underheat & no feedback thru Gr/Wh wire at defrst start21 Defrost overheat22 No feedback thru Gr/Wh wire at defrost start23 Defrost overheat & no feedback thru Gr/Wh wire at defrost start24 Defrost underheat30 Excess IM Water Valve Solenoid Activation (> 15 Seconds)40 Excessive Freezer Comp Run50 Excessive Refrigerator Comp Run

NOTE: To clear Error Codes, see next page.

600-2 SERIES

Page 58: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 58

600-2 SERIES

» Clearing Error Codes

1. Unit must be ON

2. Repair problem

3. Press and hold Bell ON/OFF key for 15 seconds

» Manual Component Activation Mode

(Energizes cooling system for 5 minutes)

1. Unit must be ON

2. Press desired COLDER & UNIT ON/OFF keys simultane-

ously for 10 seconds

NOTE: After performing the above key strokes (depending onCOLDER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

--1188 SERVICE (Illuminated) FFEETemperature of F (Freezer Evaporator)

OR2299 SERVICE (Illuminated) rEETemperature of rE (Refrigerator Evaporator)

Page 59: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 59

600-2 SERIES» Temperature Log Recall Mode

(Compartment Temperature History Only)

1. Unit must be ON

2. Press desired WARMER & UNIT ON/OFF keys simultane-

ously, then release both keys

NOTE: After performing the above key strokes (depending onCOLDER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

3388 SERVICE (Illuminated) 00112 hour compartment temperature average (at left) with

index number. Number 1 is most recent 2 hour period.

NOTE: SERVICE is always illuminated at first index.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 168.

3366 1166882 hour compartment temperature average (at left) with

index number. Number 168 is oldest recorded 2 hour peri-

od.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 168 to 1.

NOTE: Possible event indicators during Temperature Log RecallMode is covered later. Temperature Log Recall Mode ends 15seconds after last key stroke.

Page 60: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 60

600-2 SERIES» Temperature Log Recall Mode

(Compartment &/or Evaporator temperature History)

1. With unit on, initiate Diagnostic Mode - Press either COLD-

ER key & UNIT ON/OFF keys simultaneously, then release

3. Toggle through temperature readings by pressing COLDER

or WARMER key until desired thermistor temperature is

observed

4. Press WARMER key for that compartment and UNIT

ON/OFF simultaneously

NOTE: After performing the above key strokes (depending onWARMER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

--1100 SERVICE (Illuminated) 00112 hour thermistor temperature average (at left) with index

number. Number 1 is most recent 2 hour period.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 168.

--1122 1166882 hour thermistor temperature average (at left) with index

number. Number 168 is oldest recorded 2 hour period.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 168 to 1.

NOTE: Possible event indicators during Temperature Log RecallMode is on next page. Temperature Log Recall Mode ends 15seconds after last key stroke.

Page 61: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 61

600-2 SERIES

Possible Event Indicators During Temperature Log Recall

b11 110077“bl” indicates index is blank, no temperature recorded yet

3366 SERVICE (Illuminated) 8899SERVICE illuminated indicates unit was switched off with

UNIT ON/OFF key

Bell (Illuminated)3388 110055BELL Illuminated indicates power failure/interruption.

- - 2288

Several consecutive Double Dashes (- -) displayed indi-

cates electronic control board is bad. Control board must

be replaced.

NOTE: Temperature Log Recall Mode will end 20 secondsafter last key stroke.

NOTE: Temperatures continue to be logged when unit isswitched off with UNIT ON/OFF key and when ShowroomMode or Manual Compartment Disable Mode is initiated.

Page 62: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 62

600-2 SERIES NOTES

Page 63: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 63

700 SERIES

Basic Input Operations

» Adjusting Set-Point (Temperature Adjust)1. Initiate Temperature Set Mode by pressing Zone key

in multiple keystrokes until desired zone/compart-

ment is reached

2. Press COLDER or WARMER keys to set tempera-

ture

NOTE: Temperature set mode will remain active for fiveseconds after the last keystroke.

» Door / Drawer Ajar ON/OFF

- Press ALARM key to activate or deactivate alarm

(Bell annunciator will appear on the LCD when acti-

vated.)

Page 64: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 64

700 SERIES

Possible Error Indicators

- -“- -” = Control is shut off. Press COLDER key to start unit.

- 2200

“- 2200 ” = Zone/Compartment thermistor fault. Repair wiringor replace thermistor.

5555

“5555” = Zone/Compartment thermistor shorted. Repair wiringor replace thermistor.

SSu“SSu” = Blue wire of display cable unhooked or faulty. Repairwiring.

- 8888“- 8888 ” = Red Wire of display cable unhooked or faulty, toplights are off and keys are inoperative. Repair wiring.

Page 65: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 65

700 SERIES NOTES

Page 66: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 66

700-2 SERIES (Tall Units)

Basic Input Operations

» Power ON/OFF

- Press UNIT ON/OFF key

» Adjusting Set-Point (Temperature Adjust)- Press COLDER or WARMER keys of desired com-

partment

NOTE: Actual compartment temp. is displayed 10 sec-onds after last keystroke.

» Icemaker ON/OFF

- Press ICE ON/OFF key

» Door Ajar Alarm ON/OFF

- Press Bell ON/OFF key

Page 67: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 67

700-2 SERIES (Tall Units)

Unique Input Operations

» Temperature Units Selection Mode (°F or °C Display)- Within first minute of power up, press Bell ON/OFF key

& UNIT ON/OFF key simultaneously for 5 seconds

» Sabbath Mode (Disables lighting)1. Switch unit OFF

2. Press & hold UNIT ON/OFF key for 10 seconds

NOTE: To exit Sabbath Mode, repeat steps above.» Showroom Mode (Disables all but lighting)

1. Switch unit OFF

2. Press COLDER, WARMER & UNIT ON/OFF keys

simultaneously

NOTE: To exit Showroom Mode, repeat steps above.» Compartment Disable Mode (Disables compartment cool-

ing, “- -” appears on LCD)1. Switch unit OFF

2. Press desired WARMER & UNIT ON/OFF keys simulta-

neously

NOTE: To return to normal operation, repeat steps above.» Manual Defrost

- Press & hold ICE ON/OFF key for 5 seconds.

Page 68: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 68

700-2 SERIES (Tall Units)

Possible Error Indicators

NOTE: Temperatures shown are for reference only, actual tempera-tures may vary.

EEEE SERVICE (Flashing) 3388Freezer compartment thermistor Fault

0000 SERVICE (Flashing) EEEERefrigerator compartment thermistor fault

0000 SERVICE (Flashing) 3388Several excessive compressor run periods OR

Refrigerator evaporator thermistor fault

SERVICE (Flashing)

0000 ICE (Flashing) 3388Water valve energized longer than 15 seconds. Icemaker

system disabled.

NOTE: A 45 minute dwell follows each IM cycles (no powerto Icemaker). To bypass 45 minute dwell, Switch unit OFFthen back ON.

NOTE:To clear Error Indicators, repair problem then switch unitOFF and back ON.

Page 69: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 69

700-2 SERIES (Tall Units)

Troubleshooting Input Operations

» Diagnostic Mode

1. Unit must be ON

2. Press COLDER & UNIT ON/OFF keys simultaneously, then

release both keys

NOTE: After performing the above key strokes, the following willappear on the LCD. Temperatures shown are for reference only,actual temperatures may vary.

--0055 SERVICE (Illuminated) FFTemperature of F (Freezer Compartment)

- Press COLDER key to toggle to next reading

4400 SERVICE (Illuminated) rTemperature of r (Refrigerator Compartment)

- Press COLDER key to toggle to next reading

--1122 SERVICE (Illuminated) FFEETemperature of FE (Freezer Evaporator)

- Press COLDER key to toggle to next reading

2299 SERVICE (Illuminated) rEETemperature of rE (Refrigerator Evaporator)

- Pressing the COLDER key at this time will take the display

back to the first reading, the freezer compartment tempera-

ture.

(CONTINUED)

Page 70: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 70

700-2 SERIES (Tall Units)

(CONTINUED)

NOTE: If “EECC” (Error Code) is displayed (after serial#1759163), see Error Code Table on next page.

NOTE: If “EEEE” is displayed in place of temperature,thermistor in that location is faulty.

NOTE: If “SSr” is displayed in place of temperature,unit is in Showroom Mode.

NOTE: Diagnostic Mode will end 10 seconds afterlast key stroke.

Page 71: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 71

700-2 SERIES (Tall Units)Starting W/ Serial #1759163

Error Code Table

CODE INDICATION

05 Ref. cabinet therm. read open, short or erratic temp for 10+ sec’s06 Ref. evap. therm. read open, short or erratic temp for 10+ sec’s07 Fre. cabinet therm. read open, short or erratic temp for 10+ sec’s08 Fre. evap. therm. read open, short or erratic temp for 10+ sec’s20 Defrost underheat & no feedback thru Gr/Wh wire at defrst start21 Defrost overheat22 No feedback thru Gr/Wh wire at defrost start23 Defrost overheat & no feedback thru Gr/Wh wire at defrost start24 Defrost underheat80 High VS compressor differential pressures or low voltage sup-

plied to VS compressor81 High Amperage Draw at VS compressor82 VS comp. couldn’t maintain min. speed at highest current draw83 Locked VS compressor Rotor84 Short circuit at VS compressor controller output circuit85 VS compressor inverter overheated & shut down VS compressor86 Serial communication failure between VS compressor controller

and electronic control board87 Speed information from electronic control board is out of spec.88 Electronic control board not receiving status data in response to

speed commands

NOTE: VS Compressor = Variable Speed Compressor

Page 72: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 72

700-2 SERIES (Tall Units)Starting W/ Serial #1759163

NOTE: The table on the preceding page will be updated throughaddendums when subsequent software and electrical changes occurand more error codes are added. Error Codes 80 - 88 apply to the700TF/I-2V only, which started at serial ##1898164.

» Clearing Error Codes

1. Unit must be ON

2. Repair problem

3. Press and hold Bell ON/OFF key for 15 seconds

» Manual Component Activation Mode

(Energizes cooling system for 5 minutes)

1. Unit must be ON

2. Press desired COLDER & UNIT ON/OFF keys simultane-

ously for 10 seconds

NOTE: After performing the above key strokes (depending onCOLDER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

--1188 SERVICE (Illuminated) FFEETemperature of FE (Freezer Evaporator)

OR

2299 SERVICE (Illuminated) rEETemperature of rE (Refrigerator Evaporator)

Page 73: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 73

700-2 SERIES (Tall Units)» Temperature Log Recall Mode

(Compartment Temperature History Only)

1. Unit must be ON

2. Press desired WARMER & UNIT ON/OFF keys simultane-

ously, then release both keys

NOTE: After performing the above key strokes (depending onCOLDER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

3388 SERVICE (Illuminated) 00112 hour compartment temperature average (at left) with

index number. Number 1 is most recent 2 hour period.

NOTE: SERVICE is always illuminated at first index.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 168.

3366 1166882 hour compartment temperature average (at left) with

index number. Number 168 is oldest recorded 2 hour peri-

od.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 168 to 1.

NOTE: Possible event indicators during Temperature Log RecallMode is covered later. Temperature Log Recall Mode ends 10seconds after last key stroke.

Page 74: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 74

700-2 SERIES (Tall Units)Starting W/ Serial #1759163

» Temperature Log Recall Mode

(Compartment &/or Evaporator temperature History)

1. With unit on, initiate Diagnostic Mode - Press either COLD-

ER key & UNIT ON/OFF keys simultaneously, then release

3. Toggle through temperature readings by pressing COLDER

or WARMER key until desired thermistor temperature is

observed

4. Press WARMER key for that compartment and UNIT

ON/OFF simultaneously

NOTE: After performing the above key strokes (depending onWARMER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

--1100 SERVICE (Illuminated) 00112 hour thermistor temperature average (at left) with index

number. Number 1 is most recent 2 hour period.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 168.

--1122 1166882 hour thermistor temperature average (at left) with index

number. Number 168 is oldest recorded 2 hour period.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 168 to 1.

NOTE: Possible event indicators during Temperature Log RecallMode is on next page. Temperature Log Recall Mode ends 10seconds after last key stroke.

Page 75: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 75

700-2 SERIES (Tall Units)

Possible Event Indicators During Temperature Log Recall

b11 110077“bl” indicates index is blank, no temperature recorded yet

3366 SERVICE (Illuminated) 8899SERVICE illuminated indicates unit was switched off with

UNIT ON/OFF key

Bell (Illuminated)3388 110055BELL Illuminated indicates power failure/interruption.

- - 2288

Several consecutive Double Dashes (- -) displayed indi-

cates electronic control board is bad. Control board must

be replaced.

NOTE: Temperature Log Recall Mode will end 15 secondsafter last key stroke.

NOTE: Temperatures continue to be logged when unit isswitched off with UNIT ON/OFF key and when ShowroomMode or Manual Compartment Disable Mode is initiated.

Page 76: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 76

700-2 SERIES (Tall Units) NOTES

Page 77: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 77

700-3 SERIES - TALL UNITS

Basic Input Operations

» Power ON/OFF

- Press UNIT ON/OFF key

» Adjusting Set-Point (Temperature Adjust)- Press COLDER or WARMER keys of desired com-

partment

NOTE: Actual compartment temp. is displayed 10 sec-onds after last keystroke.

» Icemaker ON/OFF

- Press ICE ON/OFF key

» Door Ajar Alarm ON/OFF

- Press Bell ON/OFF key

Page 78: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 78

700-3 SERIES - TALL UNITS

Unique Input Operations

» Temperature Units Selection Mode (°F or °C Display)- Within first minute of power up, press Bell ON/OFF key

& UNIT ON/OFF key simultaneously for 5 seconds

» Sabbath Mode (Disables lighting)1. Switch unit OFF

2. Press & hold UNIT ON/OFF key for 10 seconds

NOTE: To exit Sabbath Mode, press UNIT ON/OFF Key.» Showroom Mode (Disables all but lighting)

1. Switch unit OFF

2. Press COLDER, WARMER & UNIT ON/OFF keys

simultaneously

NOTE: To exit Showroom Mode, repeat steps above.» Compartment Disable Mode (Disables compartment cool-

ing, “- -” appears on LCD)1. Switch unit OFF

2. Press desired WARMER & UNIT ON/OFF keys simulta-

neously

NOTE: To return to normal operation, repeat steps above.» Manual Defrost

- Press & hold ICE ON/OFF key for 5 seconds.

Page 79: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 79

700-3 SERIES - TALL UNITS

Possible Error Indicators

NOTE: Temperatures shown are for reference only, actual tempera-tures may vary.

EEEE SERVICE (Flashing) 3388Freezer compartment thermistor fault

0000 SERVICE (Flashing) EEEERefrigerator compartment thermistor fault

0000 SERVICE (Flashing) 3388Several excessive compressor run periods OR

Refrigerator evaporator thermistor fault

SERVICE (Flashing)

0000 ICE (Flashing) 3388Water valve energized longer than 15 seconds, five consec-

utive times. Icemaker system disabled 24 hours each time.

NOTE: A 45 minute dwell follows each IM cycles (no powerto Icemaker). To bypass 45 minute dwell, Switch ice makersystem OFF then back ON.

0000 SERVICE (Steady, not Flashing)3388Error Codes logged and observed but not cleared.

NOTE: To clear Error Codes, press bell ON/OFF key for 15 sec-onds.

Page 80: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 80

700-3 SERIES - TALL UNITS

Troubleshooting Input Operations

» Diagnostic Mode

1. Unit must be ON

2. Press COLDER & UNIT ON/OFF keys simultaneously, then

release both keys

NOTE: After performing the above key strokes, the following willappear on the LCD. Temperatures shown are for referenceonly, actual temperatures may vary.

--0055 SERVICE (Illuminated) FFTemperature of F (Freezer Compartment)

- Press COLDER key to toggle to next reading

4400 SERVICE (Illuminated) rTemperature of r (Refrigerator Compartment)

- Press COLDER key to toggle to next reading

--1122 SERVICE (Illuminated) FFEETemperature of FE (Freezer Evaporator)

- Press COLDER key to toggle to next reading

2299 SERVICE (Illuminated) rEETemperature of rE (Refrigerator Evaporator)

- Pressing the COLDER key at this time will take the display

back to the first reading, the freezer compartment tempera-

ture.

(CONTINUED)

Page 81: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 81

700-3 SERIES - TALL UNITS(CONTINUED)

NOTE: If “EECC” (Error Code) is displayed, see Error CodeTable on next page.

NOTE: If “EEEE” is displayed in place of temperature, ther-mistor in that location is faulty.

NOTE: If “SSr” is displayed in place of temperature, unit isin Showroom Mode.

NOTE: If “SSPP”””is displayed, that is the speed the variablespeed compressor is operating at.

NOTE: Diagnostic Mode will end 10 seconds after lastkey stroke.

NOTE: To clear Error Indicators, repair problem then switch unitOFF and back ON. To clear Error Codes, press bell ON/OFF keyfor 15 seconds.

Page 82: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 82

Error Code Table

CODE INDICATION

05 Ref. cabinet therm. read open, short or erratic temp for 10+ sec’s06 Ref. evap. therm. read open, short or erratic temp for 10+ sec’s07 Fre. cabinet therm. read open, short or erratic temp for 10+ sec’s08 Fre. evap. therm. read open, short or erratic temp for 10+ sec’s20 Defrost underheat & no feedback thru Gr/Wh wire at defrst start21 Defrost overheat22 No feedback thru Gr/Wh wire at defrost start23 Defrost overheat & no feedback thru Gr/Wh wire at defrost start24 Defrost underheat30 Excess IM Water Valve Solenoid Activation (> 15 Seconds)40 Excessive Freezer Comp Run50 Excessive Refrigerator Comp Run

NOTE: To clear Error Codes, see next page.

700-3 SERIES - TALL UNITS

Page 83: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 83

700-3 SERIES - TALL UNITS

» Clearing Error Codes

1. Unit must be ON

2. Repair problem

3. Press and hold Bell ON/OFF key for 15 seconds

» Manual Component Activation Mode

(Energizes cooling system for 5 minutes)

1. Unit must be ON

2. Press desired COLDER & UNIT ON/OFF keys simultane-

ously for 10 seconds

NOTE: After performing the above key strokes (depending onCOLDER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

--1188 SERVICE (Illuminated) FFEETemperature of F (Freezer Evaporator)

OR2299 SERVICE (Illuminated) rEETemperature of rE (Refrigerator Evaporator)

Page 84: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 84

700-3 SERIES - TALL UNITS» Temperature Log Recall Mode

(Compartment Temperature History Only)

1. Unit must be ON

2. Press desired WARMER & UNIT ON/OFF keys simultane-

ously, then release both keys

NOTE: After performing the above key strokes (depending onCOLDER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

3388 SERVICE (Illuminated) 00112 hour compartment temperature average (at left) with

index number. Number 1 is most recent 2 hour period.

NOTE: SERVICE is always illuminated at first index.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 168.

3366 1166882 hour compartment temperature average (at left) with

index number. Number 168 is oldest recorded 2 hour peri-

od.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 168 to 1.

NOTE: Possible event indicators during Temperature Log RecallMode is covered later. Temperature Log Recall Mode ends 15seconds after last key stroke.

Page 85: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 85

700-3 SERIES - TALL UNITS» Temperature Log Recall Mode

(Compartment &/or Evaporator temperature History)

1. With unit on, initiate Diagnostic Mode - Press either COLD-

ER key & UNIT ON/OFF keys simultaneously, then release

3. Toggle through temperature readings by pressing COLDER

or WARMER key until desired thermistor temperature is

observed

4. Press WARMER key for that compartment and UNIT

ON/OFF simultaneously

NOTE: After performing the above key strokes (depending onWARMER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

--1100 SERVICE (Illuminated) 00112 hour thermistor temperature average (at left) with index

number. Number 1 is most recent 2 hour period.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 168.

--1122 1166882 hour thermistor temperature average (at left) with index

number. Number 168 is oldest recorded 2 hour period.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 168 to 1.

NOTE: Possible event indicators during Temperature Log RecallMode is on next page. Temperature Log Recall Mode ends 15seconds after last key stroke.

Page 86: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 86

700-3 SERIES - TALL UNITS

Possible Event Indicators During Temperature Log Recall

b11 110077“bl” indicates index is blank, no temperature recorded yet

3366 SERVICE (Illuminated) 8899SERVICE illuminated indicates unit was switched off with

UNIT ON/OFF key

Bell (Illuminated)3388 110055BELL Illuminated indicates power failure/interruption.

- - 2288

Several consecutive Double Dashes (- -) displayed indi-

cates electronic control board is bad. Control board must

be replaced.

NOTE: Temperature Log Recall Mode will end 20 secondsafter last key stroke.

NOTE: Temperatures continue to be logged when unit isswitched off with UNIT ON/OFF key and when ShowroomMode or Manual Compartment Disable Mode is initiated.

Page 87: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 87

700-3 SERIES - TALL UNITS NOTES

Page 88: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 88

700-2 SERIES (Base Units)

Basic Input Operations

» Power ON/OFF

- Press UNIT ON/OFF key

» Adjusting Set-Point (Temperature Adjust)- Press COLDER or WARMER keys of desired com-

partment

NOTE: Actual compartment temp. is displayed 10 sec-onds after last keystroke.

» Icemaker ON/OFF

- Press ICE ON/OFF key

» Door Ajar Alarm ON/OFF

- Press Bell ON/OFF key

Page 89: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 89

700-2 SERIES (Base Units)

Unique Input Operations

» Temperature Units Selection Mode (°F or °C Display)- Within first minute of power up, press Bell ON/OFF key

& UNIT ON/OFF key simultaneously for 5 seconds

» Sabbath Mode (Disables lighting)1. Switch unit OFF

2. Press & hold UNIT ON/OFF key for 10 seconds

NOTE: To exit Sabbath Mode, repeat steps above.» Showroom Mode (Disables all but lighting)

1. Switch unit OFF

2. Press COLDER, WARMER & UNIT ON/OFF keys

simultaneously

NOTE: To exit Showroom Mode, repeat steps above.» Manual Defrost

- Press & hold ICE ON/OFF key for 5 seconds.

Page 90: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 90

700-2 SERIES (Base Units)

Possible Error Indicators

NOTE: Temperatures shown are for reference only, actual tempera-tures may vary.

EEEE SERVICE (Flashing) 3388700BR lower compartment thermistor Fault

3388 SERVICE (Flashing) EEEE700BR upper compartment thermistor fault

4455 SERVICE (Flashing) 4455700BR evaporator thermistor fault

EE00700BR & 700BF communication error between

control board & control panel

EE33700BR & 700BF communication error between

control board & control panel

EEEE SERVICE (Flashing)700BF compartment thermistor Fault

NOTE:To clear Error Indicators, repair problem.

Page 91: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 91

700-2 SERIES (Base Units)

Troubleshooting Input Operations

» Diagnostic Mode

1. Unit must be ON

2. Press COLDER & UNIT ON/OFF keys simultaneously, then

release both keys

NOTE: After performing the above key strokes, the following willappear on the LCD. Temperatures shown are for reference only,actual temperatures may vary.

If Model 700BF:

0000 SERVICE (Illuminated) FFTemperature of F (Freezer Compartment)

- Press COLDER key to toggle to next reading

--1100 SERVICE (Illuminated) EETemperature of E (Freezer Evaporator)

If Model 700BR:

3366 SERVICE (Illuminated) LLTemperature of L (Lower Compartment)

3366 SERVICE (Illuminated) UUTemperature of U (Upper Compartment)2299 SERVICE (Illuminated) EETemperature of E (Refrigerator Evaporator)

Page 92: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 92

700-2 SERIES (Base Units) Notes

Page 93: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 93

700-3 SERIES - BASE UNITS

Basic Input Operations

» Power ON/OFF

- Press UNIT ON/OFF key

» Adjusting Set-Point (Temperature Adjust)- Press COLDER or WARMER keys of desired com-

partment

NOTE: Actual compartment temp. is displayed 10 sec-onds after last keystroke.

» Icemaker ON/OFF

- Press ICE ON/OFF key

» Door Ajar Alarm ON/OFF

- Press Bell ON/OFF key

Page 94: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 94

700-3 SERIES - BASE UNITS

Unique Input Operations

» Temperature Units Selection Mode (°F or °C Display)- Within first minute of power up, press Bell ON/OFF key

& UNIT ON/OFF key simultaneously for 5 seconds

» Sabbath Mode (Disables lighting)1. Switch unit OFF

2. Press & hold UNIT ON/OFF key for 10 seconds

NOTE: To exit Sabbath Mode, press UNIT ON/OFF Key.» Showroom Mode (Disables all but lighting)

1. Switch unit OFF

2. Press COLDER, WARMER & UNIT ON/OFF keys

simultaneously

NOTE: To exit Showroom Mode, repeat steps above.» Compartment Disable Mode (Disables compartment cool-

ing, “- -” appears on LCD)1. Switch unit OFF

2. Press desired WARMER & UNIT ON/OFF keys simulta-

neously

NOTE: To return to normal operation, repeat steps above.» Manual Defrost

- Press & hold ICE ON/OFF key for 5 seconds.

Page 95: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 95

700-3 SERIES - BASE UNITS

Possible Error Indicators

NOTE: Temperatures shown are for reference only, actual tempera-tures may vary.

EEEE SERVICE (Flashing) 3388Freezer compartment thermistor fault

0000 SERVICE (Flashing) EEEERefrigerator compartment thermistor fault

0000 SERVICE (Flashing) 3388Several excessive compressor run periods OR

Refrigerator evaporator thermistor fault

SERVICE (Flashing)

0000 ICE (Flashing) 3388Water valve energized longer than 15 seconds, five consec-

utive times. Icemaker system disabled 24 hours each time.

NOTE: A 45 minute dwell follows each IM cycles (no powerto Icemaker). To bypass 45 minute dwell, Switch ice makersystem OFF then back ON.

0000 SERVICE (Steady, not Flashing)3388Error Codes logged and observed but not cleared.

NOTE: To clear Error Codes, press bell ON/OFF key for 15 sec-onds.

Page 96: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 96

700-3 SERIES - BASE UNITS

Troubleshooting Input Operations

» Diagnostic Mode

1. Unit must be ON

2. Press COLDER & UNIT ON/OFF keys simultaneously, then

release both keys

NOTE: After performing the above key strokes, the following willappear on the LCD. Temperatures shown are for referenceonly, actual temperatures may vary.

--0055 SERVICE (Illuminated) FFTemperature of F (Freezer Compartment)

- Press COLDER key to toggle to next reading

4400 SERVICE (Illuminated) rTemperature of r (Refrigerator Compartment)

- Press COLDER key to toggle to next reading

--1122 SERVICE (Illuminated) EETemperature of E (Evaporator)

- Pressing the COLDER key at this time will take the display

back to the first reading, the freezer compartment tempera-

ture.

(CONTINUED)

Page 97: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 97

700-3 SERIES - BASE UNITS(CONTINUED)

NOTE: If “EECC” (Error Code) is displayed, see Error CodeTable on next page.

NOTE: If “EEEE” is displayed in place of temperature, ther-mistor in that location is faulty.

NOTE: If “SSr” is displayed in place of temperature, unit isin Showroom Mode.

NOTE: Diagnostic Mode will end 10 seconds after lastkey stroke.

NOTE: To clear Error Indicators, repair problem then switch unitOFF and back ON. To clear Error Codes, press bell ON/OFF keyfor 15 seconds.

Page 98: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 98

Error Code Table

CODE INDICATION

05 Ref. cabinet therm. read open, short or erratic temp for 10+ sec’s06 Ref. evap. therm. read open, short or erratic temp for 10+ sec’s07 Fre. cabinet therm. read open, short or erratic temp for 10+ sec’s08 Fre. evap. therm. read open, short or erratic temp for 10+ sec’s20 Defrost underheat & no feedback thru Gr/Wh wire at defrst start21 Defrost overheat22 No feedback thru Gr/Wh wire at defrost start23 Defrost overheat & no feedback thru Gr/Wh wire at defrost start24 Defrost underheat30 NA40 Excessive Freezer Comp Run50 Excessive Refrig. Comp Run (Excessive Ref Fan Run 700BC/I)

NOTE: To clear Error Codes, see next page.

700-3 SERIES - BASE UNITS

Page 99: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 99

700-3 SERIES - BASE UNITS

» Clearing Error Codes

1. Unit must be ON

2. Repair problem

3. Press and hold Bell ON/OFF key for 15 seconds

» Manual Component Activation Mode

(Energizes cooling system for 5 minutes)

1. Unit must be ON

2. Press desired COLDER & UNIT ON/OFF keys simultane-

ously for 10 seconds

NOTE: After performing the above key strokes (depending onCOLDER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

--0055 SERVICE (Illuminated) EETemperature of E (Evaporator)

OR3366 SERVICE (Illuminated) rTemperature of r (Refrigerator Compartment)

Page 100: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 100

700-3 SERIES - BASE UNITS

» Temperature Log Recall Mode

(Compartment Temperature History Only)

1. Unit must be ON

2. Press desired WARMER & UNIT ON/OFF keys simultane-

ously, then release both keys

NOTE: After performing the above key strokes (depending onCOLDER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

3388 SERVICE (Illuminated) 00112 hour compartment temperature average (at left) with

index number. Number 1 is most recent 2 hour period.

NOTE: SERVICE is always illuminated at first index.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 168.

3366 1166882 hour compartment temperature average (at left) with

index number. Number 168 is oldest recorded 2 hour peri-

od.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 168 to 1.

NOTE: Possible event indicators during Temperature Log RecallMode is covered later. Temperature Log Recall Mode ends 15seconds after last key stroke.

Page 101: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 101

700-3 SERIES - BASE UNITS» Temperature Log Recall Mode

(Compartment &/or Evaporator temperature History)

1. With unit on, initiate Diagnostic Mode - Press either COLD-

ER key & UNIT ON/OFF keys simultaneously, then release

3. Toggle through temperature readings by pressing COLDER

or WARMER key until desired thermistor temperature is

observed

4. Press WARMER key for that compartment and UNIT

ON/OFF simultaneously

NOTE: After performing the above key strokes (depending onWARMER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

--1100 SERVICE (Illuminated) 00112 hour thermistor temperature average (at left) with index

number. Number 1 is most recent 2 hour period.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 168.

--1122 1166882 hour thermistor temperature average (at left) with index

number. Number 168 is oldest recorded 2 hour period.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 168 to 1.

NOTE: Possible event indicators during Temperature Log RecallMode is on next page. Temperature Log Recall Mode ends 15seconds after last key stroke.

Page 102: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 102

700-3 SERIES - BASE UNITS

Possible Event Indicators During Temperature Log Recall

b11 110077“bl” indicates index is blank, no temperature recorded yet

3366 SERVICE (Illuminated) 8899SERVICE illuminated indicates unit was switched off with

UNIT ON/OFF key

Bell (Illuminated)3388 110055BELL Illuminated indicates power failure/interruption.

- - 2288

Several consecutive Double Dashes (- -) displayed indi-

cates electronic control board is bad. Control board must

be replaced.

NOTE: Temperature Log Recall Mode will end 20 secondsafter last key stroke.

NOTE: Temperatures continue to be logged when unit isswitched off with UNIT ON/OFF key and when ShowroomMode or Manual Compartment Disable Mode is initiated.

Page 103: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 103

700-3 SERIES - BASE UNITSService Input Operations

» Auto Model Configuration Mode

If a new main control board is installed during a service call,

double dashes ( - - ) will appear on the LCD indicating the board

must be configured for the model it was installed into.

1. Open bottom drawer.

2. With unit on - Press COLDER or WARMER key to toggle

through model codes, then stop when proper code is dis-

played (See Model Code Table on next page).

3. Press UNIT ON/OFF key to store configuration.

» Manual Entry Model Configuration Mode

If control board configuration needs to be verified or changed:

1. Open bottom drawer.

2. With unit on - Press COLDER and UNIT ON/OFF keys

simultaneously, then release.

3. Press Bell ON/OFF and UNIT ON/OFF keys simultaneous-

ly, then release.

4. Press COLDER or WARMER key to toggle through model

codes, then stop when proper code is displayed (See

Model Code Table on next page).

3. Press UNIT ON/OFF key to store configuration.

Page 104: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 104

700-3 SERIES - BASE UNITS

br 700BR

bC 700BC

27 427R

bF 700BFI

2r UC-24R / UC-24RO

2C UC-24C

2b UC-24B

MODEL CODE TABLE

CODE MODEL

Page 105: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 105

700-2 SERIES BASE UNITS Notes

Page 106: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 106

MODEL 648PRO & ICB648PRO

Basic Input Operations

» Power ON/OFF

- Press POWER key

» Adjusting Set-Point (Temperature Adjust)- Press COLDER or WARMER keys of desired com-

partment

NOTE: Actual compartment temp. is displayed 10 sec-onds after last keystroke.

» Icemaker ON/OFF

- Press ICE MAKER key

» Door Ajar Alarm ON/OFF

- Press ALARM key

» Accent Lights ON/OFF

- Press LIGHT key

Page 107: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 107

MODEL 648PRO & ICB648PRO

Unique Input Operations

» Temperature Units Selection Mode (°F or °C Display)- Within first minute of power up, press ALARM key &

POWER key simultaneously for 5 seconds

» Sabbath Mode

1. Switch unit OFF

2. Press & hold POWER key for 10 seconds

NOTE: To exit Sabbath Mode, repeat steps above.» Showroom Mode (Disables all but lighting)

1. Switch unit OFF

2. Press COLDER, WARMER & POWER keys simultane-

ously

NOTE: To exit Showroom Mode, repeat steps above.» Zone Disable Mode (Disables compartment cooling, “- -”

appears on LCD)1. Switch unit OFF

2. Press desired WARMER & POWER keys simultaneous-

ly

NOTE: To return to normal operation, repeat steps above.» Manual Defrost

- Press & hold ICE MAKER key for 5 seconds.

Page 108: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 108

MODEL 648PRO & ICB648PRO

Possible Error Indicators

NOTE: Temperatures shown are for reference only, actual tempera-tures may vary.

EEEE 3388 SERVICE (Flashing) 3388Freezer zone thermistor fault

00 EEEE SERVICE (Flashing) 3388Upper Refrigerator zone thermistor fault

00 3388 SERVICE (Flashing) EEEELower Refrigerator zone thermistor fault

Icemaker Icon (Flashing)

00 3388 SERVICE (Flashing) 3388Water valve energized longer than 15 seconds, five consec-

utive times. Icemaker system disabled 24 hours each time.

NOTE: A 45 minute dwell follows each IM cycles (no powerto Icemaker). To bypass 45 minute dwell, Switch ice makersystem OFF then back ON.

00 3388 SERVICE (Flashing) 3388Multiple possibilities, see error code table

Page 109: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 109

COLDERFor Service Mode, Press and hold then press POWER

ICE MAKER

ALARM

WARMER

COLDER

SERVICE MODE1) DIAGNOSTICS

<-DIAGNOSTICS1) SELF TEST2) ERROR HISTORY 3) THERMISTORS4) ACTIVE ZONE5) STATISTICS

For complete Service Mode menu see back

of wiring diagram.

SERVICE MODE2) OP STATUS

SERVICE MODE3) MODEL INFO

SERVICE MODE4) VERSION INFO

1

1

3

4

Pro48 Zones

->->->->->

->

->

->

->

MODEL 648PRO & ICB648PRO

Initiating Service Mode:

Page 110: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 110

648PRO & ICB648PRO Error Code TableEC ZONE SERVICE INSTRUCTION

01 X Zone “X” Cabinet Thermistor Failure (Device or Wiring)02 X Zone “X” Evaporator Thermistor Failure (Device or Wiring)03 X Zone “X” Condenser Thermistor Failure (Device or Wiring)04 0 Ambient Thermistor Failure (Device or Wiring)20 X Check Zone “X” Defrost Bi-metal for Proper Operation21 X Check Zone “X” Defrost Bi-metal for Proper Operation22 X Check Zone “X” Defrost Wiring23 X Check Zone “X” Defrost Wiring24 X Check Zone “X” Defrost Heater Ohms30 0 Check for Stuck Icemaker or Water Valve Failure35 X Check Zone “X” Fan, Fan Speed Error40 X Zone “X” Excessive Run41 X Check Zone “X” Compressor and Wiring42 0 Check Condenser Fan and/or Wiring43 X Check Left Refrigerant Valve and Wiring44 X Check Zone “X” Glass Door Heater and Wiring45 X Errors Detectable with Red Door Switches-Disabled Now.

Check Overhead Lighting46 0 Check Ice Accessory Wiring for Open Circuit47 3 Check Accent Lighting Wiring for Short Circuit80 X Check Power to Compressor Controller for Zone “X”,

Troubleshoot with Manual Activation Mode83 X Replace Zone “X” VS Compressor and Filter-Drier84 X Check Zone “X” VS Compressor Wiring85 X Zone “X” VS Compressor Control Overheat86 X Check Communication Wiring, Replace Zone “X” VS

Controller87 X Check for Broken Wiring or Open Defrost Heater89 X Check Icemaker Solenoid Valve and Wiring90 X Change Main Control Board

Page 111: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 111

92 0 Check Keypad Wiring93 0 Replace Keypad94 1 Check Wiring / Replace User Display #194 3 Check Wiring / Replace User Display #296 0 Datalogger Malfunction97 0 Check Communications Cables / Connectors98 0 Brownout Check Input Power Supply

648PRO & ICB648PRO Error Code Table

Explanation of zone error codes

If “X” = 0, Failure was with a common component.

If “X” = 1, Failure occurred in Zone 1 or left system.

If “X” = 2, Failure occurred in Zone 2.

If “X” = 3, Failure occurred in Zone 3 or right system.

If “X” = 4, Failure occurred in Zone 4.

Note: Zone 2 and zone 4 may or may not be present depend-ing on model.

Page 112: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 112

MODEL 648PRO & ICB648PRO Notes

Page 113: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 113

UC SERIES

Basic Input Operations

» Power ON/OFF

- Press POWER key

» Adjusting Set-Point (Temperature Adjust)- Press COLDER or WARMER keys of desired com-

partment

NOTE: Actual compartment temp. is displayed 10 sec-onds after last keystroke.

Page 114: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 114

UC SERIES

Unique Input Operations

» Temperature Units Selection Mode (°F or °C Display)(Model UC-24C ONLY) Within 1st minute of power up:

1. Press Freezer WARMER & POWER keys

simultaneously

2. Press Freezer WARMER & COLDER keys

simultaneously for 15 seconds

(Models UC-24B/R/RO ONLY) Within 1st min. of power up:

1. Press WARMER & POWER keys simultaneously

2. Press WARMER & COLDER keys simultaneously for 15

seconds

» Sabbath Mode (Disables lighting)1. Switch unit OFF

2. Press & hold POWER key for 10 seconds

NOTE: To exit Sabbath Mode, press UNIT ON/OFF Key.» Showroom Mode (Disables all but lighting)

1. Switch unit OFF

2. Press COLDER, WARMER & POWER keys

simultaneously

NOTE: To exit Showroom Mode, repeat steps above.

» Manual Defrost (UC-24C ONLY)

- Press & hold Freezer WARMER, COLDER & POWER

keys simultaneously for 5 seconds

Page 115: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 115

UC SERIES

Possible Error Indicators

NOTE: Temperatures shown are for reference only, actual tempera-tures may vary.

EEEE SERVICE (Flashing) 3388Freezer compartment thermistor fault

0000 SERVICE (Flashing) EEEERefrigerator compartment thermistor fault

0000 SERVICE (Flashing) 3388Several excessive compressor run periods OR

evaporator thermistor fault

0000 SERVICE (Steady, not Flashing)3388Error Codes logged and observed but not cleared.

NOTE: To clear Error Codes:» Model UC-24C ONLY:

Press Freezer WARMER & COLDER keys simultaneouslyfor 15 seconds

» Models UC-24B/R/RO ONLY:Press WARMER & COLDER keys simultaneously for 15 seconds

Page 116: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 116

UC SERIES

Troubleshooting Input Operations

» Diagnostic Mode

1. Unit must be ON

2. Press COLDER & POWER keys simultaneously, then

release both keys

NOTE: After performing the above key strokes, the following willappear on the LCD. Temperatures shown are for referenceonly, actual temperatures may vary.

--0055 SERVICE (Illuminated) FFTemperature of F (Freezer Compartment)

- Press COLDER key to toggle to next reading

4400 SERVICE (Illuminated) rTemperature of r (Refrigerator Compartment)

- Press COLDER key to toggle to next reading

--1122 SERVICE (Illuminated) EETemperature of E (Evaporator)

- Pressing the COLDER key at this time will take the display

back to the first reading, the freezer compartment tempera-

ture.

(CONTINUED)

Page 117: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 117

UC SERIES(CONTINUED)

NOTE: If “EECC” (Error Code) is displayed, see Error CodeTable on next page.

NOTE: If “EEEE” is displayed in place of temperature, ther-mistor in that location is faulty.

NOTE: If “SSr” is displayed in place of temperature, unit isin Showroom Mode.

NOTE: Diagnostic Mode will end 10 seconds after lastkey stroke.

NOTE: To clear Error Indicators, repair problem then switch unitOFF and back ON. To clear Error Codes:» Model UC-24C ONLY:

Press Freezer WARMER & COLDER keys simultaneously

for 15 seconds

» Models UC-24B/R/RO ONLY:

Press WARMER & COLDER keys simultaneously for 15

seconds

Page 118: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 118

Error Code Table

CODE INDICATION

05 Ref. cabinet therm. read open, short or erratic temp for 10+ sec’s06 Ref. evap. therm. read open, short or erratic temp for 10+ sec’s07 Fre. cabinet therm. read open, short or erratic temp for 10+ sec’s08 Fre. evap. therm. read open, short or erratic temp for 10+ sec’s20 Defrost underheat & no feedback thru Gr/Wh wire at defrst start21 Defrost overheat22 No feedback thru Gr/Wh wire at defrost start23 Defrost overheat & no feedback thru Gr/Wh wire at defrost start24 Defrost underheat30 NA40 Excessive Freezer Comp Run50 Excessive Refrigerator Comp Run

NOTE: To clear Error Codes, see next page.

UC SERIES

Page 119: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 119

UC SERIES

» Clearing Error Codes

1. Unit must be ON

2. Repair problem

3a. Press Freezer WARMER & COLDER keys simultane-

ously for 15 seconds (Model UC-24C ONLY)3b. Press WARMER & COLDER keys simultaneously for 15

seconds (Models UC-24B/R/RO ONLY)

» Manual Component Activation Mode

(Energizes cooling system for 5 minutes)

1. Unit must be ON

2. Press desired COLDER & POWER keys simultaneously for

10 seconds

NOTE: After performing the above key strokes (depending onCOLDER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

--0022 SERVICE (Illuminated) FFTemperature of E (Evaporator)

OR4400 SERVICE (Illuminated) rTemperature of r (Refrigerator Compartment)

Page 120: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 120

UC SERIES

» Temperature Log Recall Mode

(Compartment Temperature History Only)

1. Unit must be ON

2. Press desired WARMER & POWER keys simultaneously,

then release both keys

NOTE: After performing the above key strokes (depending onCOLDER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

3388 SERVICE (Illuminated) 00112 hour compartment temperature average (at left) with

index number. Number 1 is most recent 2 hour period.

NOTE: SERVICE is always illuminated at first index.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 168.

3366 1166882 hour compartment temperature average (at left) with

index number. Number 168 is oldest recorded 2 hour peri-

od.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 168 to 1.

NOTE: Possible event indicators during Temperature Log RecallMode is covered later. Temperature Log Recall Mode ends 15seconds after last key stroke.

Page 121: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 121

UC SERIES» Temperature Log Recall Mode

(Compartment &/or Evaporator temperature History)

1. With unit on, initiate Diagnostic Mode - Press either COLD-

ER key & UNIT ON/OFF keys simultaneously, then release

3. Toggle through temperature readings by pressing COLDER

or WARMER key until desired thermistor temperature is

observed

4. Press WARMER key for that compartment and POWER

simultaneously

NOTE: After performing the above key strokes (depending onWARMER key chosen), the following will appear on the LCD.Temperatures shown are for reference only, actual temperaturesmay vary.

--1100 SERVICE (Illuminated) 00112 hour thermistor temperature average (at left) with index

number. Number 1 is most recent 2 hour period.

- Press WARMER key in multiple keystrokes to toggle up

through indexes, from 1 to 168.

--1122 1166882 hour thermistor temperature average (at left) with index

number. Number 168 is oldest recorded 2 hour period.

- Press COLDER key in multiple keystrokes to toggle down

through indexes, from 168 to 1.

NOTE: Possible event indicators during Temperature Log RecallMode is on next page. Temperature Log Recall Mode ends 15seconds after last key stroke.

Page 122: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 122

UC SERIES

Possible Event Indicators During Temperature Log Recall

b11 110077“bl” indicates index is blank, no temperature recorded yet

3366 SERVICE (Illuminated) 8899SERVICE illuminated indicates unit was switched off with

POWER key

Bell (Illuminated)3388 110055BELL Illuminated indicates power failure/interruption.

- - 2288

Several consecutive Double Dashes (- -) displayed indi-

cates electronic control board is bad. Control board must

be replaced.

NOTE: Temperature Log Recall Mode will end 20 secondsafter last key stroke.

NOTE: Temperatures continue to be logged when unit isswitched off with UNIT ON/OFF key and when ShowroomMode or Manual Compartment Disable Mode is initiated.

Page 123: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 123

UC SERIESService Input Operations

» Auto Model Configuration Mode

If a new main control board is installed during a service call,

double dashes ( - - ) will appear on the LCD indicating the board

must be configured for the model it was installed into.

1. With unit on - Press COLDER or WARMER key to toggle

through model codes, then stop when proper code is

displayed (See Model Code Table on next page).

2. Press UNIT ON/OFF key to store configuration.

» Manual Entry Model Configuration Mode

If control board configuration needs to be verified or changed:

1. With unit on - Press & hold either COLDER Key and

POWER key simultaneously.

2. Press POWER key for 15 seconds.

3. Press COLDER or WARMER key to toggle through model

codes, then stop when proper code is displayed (See

Model Code Table on next page).

4. Press POWER key to store configuration.

Page 124: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 124

UC SERIES

br 700BR

bC 700BC

27 427R

bF 700BFI

2r UC-24R / UC-24RO

2C UC-24C

2b UC-24B

MODEL CODE TABLE

CODE MODEL

Page 125: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 125

UC SERIES Notes

Page 126: 400 / 400-2 / 600 / 600-2 / 700 / 700-2 / 700-3 SERIES

PAGE 126

Notes