41104402-re en 301 489-17 - faenl.msi.comfaenl.msi.com/ftp/ce documents/68xx/ms-6871.pdf ·...
TRANSCRIPT
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. This document may be altered or revised by Compliance Certification
Services Inc. personnel only, and shall be noted in the revision section of the document.
Page 1 Total Page: 45
Rev. 00
ETSI EN 301 489-17 V1.2.1: 2002
TEST REPORT
For
Bluetooth USB Hub
Model: MS-6871
Trade Name: MSI
Issued to
MICRO-STAR INT'L CO., LTD. NO. 69, Li-De St, Jung-He City,
Taipei Hsien, Taiwan, R.O.C.
Issued by
Compliance Certification Services Inc. No. 81-1, Lane 210, Bade Rd. 2, Luchu Hsiang,
Taoyuan Hsien, (338) Taiwan, R.O.C. TEL: 886-3-324-0332 FAX: 886-3-324-5235
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 2 Rev.00
TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION............................................................................................. 3
2. EUT DESCRIPTION..................................................................................................................... 4
3. TEST METHODOLOGY.............................................................................................................. 5 3.1 UNIT OF MEASUREMENT............................................................................................... 5 3.2 ANTENNA..................................................................................................................... 5 3.3 MEASUREMENT EQUIPMENT USED .................................................................. 6 3.4 DECISION OF FINAL TEST MODE .................................................................................... 9
4. INSTRUMENT AND CALIBRATION...................................................................................... 10 4.1 MEASURING INSTRUMENT CALIBRATION.................................................... 10
5. FACILITIES AND ACCREDITATIONS.................................................................................. 11 5.1 FACILITIES ................................................................................................................. 11 5.2 EQUIPMENT................................................................................................................ 11 5.3 LABORATORY ACCREDITATIONS AND LISTINGS.......................................................... 11 5.4 TABLE OF ACCREDITATIONS AND LISTINGS ............................................................... 12
6. SETUP OF EQUIPMENT UNDER TEST................................................................................. 13 6.1 SETUP CONFIGURATION OF EUT.................................................................................. 13 6.2 SUPPORT EQUIPMENT......................................................................................... 13 6.3 TEST SETUP ................................................................................................................ 14
7. ETSI EN 301 489-1/-17 REQUIREMENTS............................................................................... 15 7.1 RADIATED EMISSION .................................................................................................. 15 7.2 AC MAINS LINE CONDUCTED EMISSION....................................................................... 17 7.3 AC MAINS HARMONIC CURRENT EMISSION ................................................................. 20 7.4 AC MAINS VOLTAGE FLUCTUATION AND FLICKER ...................................................... 22 7.5 ELECTROSTATIC DISCHARGE...................................................................................... 24 7.6 RF ELECTROMAGNETIC FIELD..................................................................................... 30 7.7 AC MAINS FAST TRANSIENTS – COMMON MODE.......................................................... 32 7.8 AC MAINS SURGE........................................................................................................ 34 7.9 AC MAINS RF – COMMON MODE.................................................................................. 36 7.10 VOLTAGE DIPS AND INTERRUPTION ............................................................................ 38
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 3 Rev.00
1. TEST RESULT CERTIFICATION Applicant: MICRO-STAR INT'L CO., LTD.
NO. 69, Li-De St, Jung-He City, Taipei Hsien, Taiwan, R.O.C.
Equipment Under Test: Bluetooth USB Hub
Trade Name: MSI
Model: MS-6871
Date of Test: November 10 ~ December 1, 2004 APPLICABLE STANDARDS
STANDARD TEST RESULT ETSI EN 301 489-17 V1.2.1: 2002 No non-compliance noted Applicable Standard Class/Limit/Criterion Test Result
ETSI EN 301 489-1 V1.4.1: 2002 EN 55022: 1998 Class B No non-compliance noted EN 61000-3-2: 2000 Class D No non-compliance noted EN 61000-3-3: 1995 + A1: 2001 Limit No non-compliance noted EN 61000-4-2: 1995 + A2: 2001 Criterion B No non-compliance noted EN 61000-4-3: 2002 + A1: 2002 Criterion A No non-compliance noted EN 61000-4-4: 1995 + A2: 2001 Criterion B No non-compliance noted EN 61000-4-5: 1995 + A1: 2001 Criterion B No non-compliance noted EN 61000-4-6: 1996 + A1: 2001 Criterion A No non-compliance noted EN 61000-4-11: 1994 + A1: 2001 Criterion B/C/C No non-compliance noted
Deviation from Applicable Standard None
The above equipment was tested by Compliance Certification Services Inc. for compliance with the requirements set forth in ETSI EN 301 489-17 V1.2.1: 2002. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties.
Approved by: Reviewed by:
Harris. W. Lai Devin Chang Executive Vice President Section Manager Compliance Certification Services Inc. Compliance Certification Services Inc.
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 4 Rev.00
2. EUT DESCRIPTION
Product Bluetooth USB Hub
Trade Name MSI
Model Number MS-6871
Model Discrepancy N/A
Module Trade Name MSI
Module Model Number MS6970
Power Supply DC 5V from upstream USB port
Frequency Range 2402 ~ 2480 MHz
Transmit Power (mean EIRP) 4.09dBm
Modulation Technique GFSK (16-QAM, 64-QAM)
Number of Channels 79 Channels
Antenna Specification Printed Antenna / Gain: -4.1dBi
Temperature Range 0 ~ +50°C
Note: for more details, please refer to the User’s manual of the EUT.
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 5 Rev.00
3. TEST METHODOLOGY All tests were performed in accordance with the procedure documented in ETSI EN 301 489-1 V1.4.1 (2002-04) as referenced in ETSI EN 301 489-17 V1.2.1 (2002-04).
3.1 UNIT OF MEASUREMENT Measurements of radiated interference are reported in terms of dB(uV/m) at a specified distance. The indicated readings on the Spectrum analyzers were converted to dB (uV/m) by use of appropriate conversion factors. Measurements of conducted interference are reported in terms of dB(uV).
The field strength is calculated by adding the Antenna Factor and Cable Factors and subtracting the Amplifier Gain from the measured reading. The following is a sample calculation:
FS = RA + AF + CF – AG
Where FS = Field Strength RA = Receiver Amplitude AF = Antenna Factor CF = Cable Attenuation Factor AG = Amplifier Gain
Assume a receiver reading of 52.5 dBuV is obtained. The Antenna Factor of 7.4dB/m and a Cable Factor of 1.1dB are added. The Amplifier Gain of 29 dB is subtracted, giving field strength of 32 dBuV/m. The 32-dBuV/m values was mathematically converted to its corresponding level in uV/m.
FS = 52.5 + 7.4 + 1.1 – 29 = 32 dBuV/m Note: Level in uV/m = Common Antilogarithm [(32 dBuV/m)/20] = 39.8 uV/m
3.2 ANTENNA The calibrated antennas used to sample the radiated field strength are mounted on a non-conductive, motorized antenna mast 10 meters from the leading edge of the turntable.
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 6 Rev.00
3.3 MEASUREMENT EQUIPMENT USED
Equipment Used for Emission Measurement Remark: Each piece of equipment is scheduled for calibration once a year.
Open Area Test Site # 3 Name of Equipment Manufacturer Model Serial Number Calibration Due
Spectrum Analyzer ADVANTEST R3132 91700456 N.C.R
EMI Test Receiver R&S ESVS10 846285/016 04/10/2005
Bilog Antenna CHASE CBL 6112B 2462 01/10/2005
Turn Table Chance most N/A N/A N.C.R
Antenna Tower Chance most N/A N/A N.C.R
Controller Chance most N/A N/A N.C.R
RF Switch ANRITSU MP59B M51067 N.C.R
Site NSA C&C Lab. N/A N/A 08/08/2005
Test S/W HTBasic (M026C)
Conducted Emission Test Site # 3
Name of Equipment Manufacturer Model Serial Number Calibration DueEMI TEST RECEIVER
9kHz-30MHz ROHDE & SCHWARZ ESHS30 828144/003 09/24/2005
TWO-LINE V-NETWORK 9kHz-30MHz
SCHAFFNER NNB41 03/10013 06/11/2005
LISN 10kHz-100MHz EMCO 3825/2 9106-1809 02/05/2005
Test S/W LabABVIEW (V 6.1)
Power Harmonic & Voltage Fluctuation/Flicker Measurement (EN 61000-3-2&-3-3)
Name of Equipment Manufacturer Model Serial Number Calibration DueHarmonic & Flicker
Tester EMC-PARTNER HARMONICS-1000 094 10/26/2005
Test S/W HARCS (Ver. 4.0)
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 7 Rev.00
Equipment Used for Immunity Measurement ESD Test Site (IEC/EN 61000-4-2)
Name of Equipment Manufacturer Model Serial Number Calibration DueESD Simulator NoiseKen ESS-2001 ESS0210582 09/13/2005
Fast Transients/Burst Test Site (IEC/EN 61000-4-4)
Name of Equipment Manufacturer Model Serial Number Calibration DueFast Transients/Burst
Generator HAEFELY TRENCH PEFT- JUNIOR 583 333-117 08/19/2005
Clamp HAEFELY TRENCH 093 506.1 080 421.13 N.C.R
Test S/W E400 Burstware (V4.19 (c)) Remark: The clamp is used only for EUT with signal cable connected and greater than 3m in length.
Radiated Electromagnetic Field Immunity Test Site (IEC/EN 61000-4-3) Name of Equipment Manufacturer Model Serial Number Calibration Due
Signal Generator Agilent 8648C 4108A05772 09/12/2005 150 Watts 80-1000MHz
Amplifier Amplifier Research 150W1000M3 306730 N.C.R
30 Watts 0.8-3.0GHz Amplifier Amplifier Research 30S1G3M1 306722 N.C.R
Power Meter Boonton 4232A-01-02 98501 07/09/2005
Power Sensor Boonton 51011-EMC 32920 07/09/2005
Power Sensor Boonton 51011-EMC 32863 07/09/2005
Log-Periodic Antenna Amplifier Research AT1080 306709 N.C.R
Microwave Horn Antenna Amplifier Research AT4002A 306750 N.C.R 6 MHz Sweep/Function
Generator AMREL FG-506 50608090006 05/18/2005
RF Test System Controller Amplifier Research SC1000M3 306666 N.C.R
Field Probe Amplifier Research FP6001 305657 03/17/2005
0.8-4.2GHz Amplifier Research DC7144A N/A N.C.R
80-1000MHz Amplifier Research DC6180A N/A N.C.R
Antenna Tower Amplifier Research TP2000 N/A N.C.R
Probe Stand Amplifier Research PS2000 N/A N.C.R
Test S/W SW1005 (Release 1.4)
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 8 Rev.00
Surge Immunity Test Site (IEC/EN EN 61000-4-5) Name of Equipment Manufacturer Model Serial Number Calibration Due
Surge Tester HAEFELY TRENCH PSUGER 4010 583 334-71 09/02/2005
CDN HAEFELY TRENCH IP6.2 148342 N.C.R.
CDN HAEFELY TRENCH DEC1A 148050 N.C.R.
Test S/W E500 Surgeware (V4.19cc)
CS Test Site (IEC/EN 61000-4-6) Name of Equipment Manufacturer Model Serial Number Calibration Due
Signal Generator Agilent 8648C 4108A05773 09/12/2005 75 Watts 10kHz-250MHz
Amplifier Amplifier Research 75A250AM1 306334 N.C.R
Power Meter Boonton 4232A-01-02 98601 07/09/2005
Power Sensor Boonton 51011-EMC 32862 07/09/2005
Power Sensor Boonton 51011-EMC 32864 07/09/2005 Power Line Coupling Decoupling Network
Fischer Custom Communications, Inc. FCC-801-M1-32A 03018 09/13/2005
Power Line Coupling Decoupling Network
Fischer Custom Communications, Inc. FCC-801-M2-16A 03026 09/06/2005
Power Line Coupling Decoupling Network
Fischer Custom Communications, Inc. FCC-801-M3-16A 03027 09/13/2005
Signal Line Coupling Decoupling Network
Fischer Custom Communications, Inc. FCC-801-T2 03016 09/06/2005
Signal Line Coupling Decoupling Network
Fischer Custom Communications, Inc. FCC-801-T4 03017 09/06/2005
EM Injection Clamp Fischer Custom Communications, Inc. F-203I-23mm 421 09/13/2005
Passive Impedance Adapters
Fischer Custom Communications, Inc. FCC-801-150-50-CDN 03053&03054 09/13/2005
Calibration Fixture Fischer Custom Communications, Inc. F-203I-CF-23mm 408 09/13/2005
Signal Line Coupling Decoupling Network
Fischer Custom Communications, Inc. FCC-801-T8-RJ45 04024 09/13/2005
Attenuator Amplifier Research HFP-575-3/6-NM NF201875106 N.C.R Coupler Amplifier Research DC2600A 306621 N.C.R Test S/W SW1005 (Release 1.4)
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 9 Rev.00
Voltage Dips/Short Interruption and Voltage Variation Immunity Test Site (IEC/EN 61000-4-11)
Name of Equipment Manufacturer Model Serial Number Calibration DueDips/Interruption and Variations Simulator
HAEFELY TRENCH PLINE 1610 080 344-05 04/07/2005
Test S/W WinPATS (V. 3.26)
3.4 DECISION OF FINAL TEST MODE 1. The following test mode was scanned during the preliminary test:
Mode 1 Transceiving --- (Operated with the Highest channel under IEEE 802.11b mode)
Mode 2 Transceiving --- (Operated with the Highest channel under IEEE 802.11g mode)
2. After the preliminary scan, the following test mode was found to produce the highest emission level.
Mode 2 Then, the EUT configuration and cable configuration of the above highest emission mode was chosen for all final test items.
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 10 Rev.00
4. INSTRUMENT AND CALIBRATION
4.1 MEASURING INSTRUMENT CALIBRATION The measuring equipment, which was utilized in performing the tests documented herein, has been calibrated in accordance with the manufacturer’s recommendations for utilizing calibration equipment, which is traceable to recognized national standards.
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 11 Rev.00
5. FACILITIES AND ACCREDITATIONS
5.1 FACILITIES All measurement facilities used to collect the measurement data are located at
No. 81-1, Lane 210, Bade Rd. 2, Luchu Hsiang, Taoyuan Hsien, Taiwan, R.O.C.
No. 199, Chunghsen Road, Hsintien City, Taipei Hsien, Taiwan, R.O.C.
The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and CISPR Publication 22.
5.2 EQUIPMENT Radiated emissions are measured with one or more of the following types of linearly polarized antennas: tuned dipole, biconical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum analyzers with preselectors and quasi-peak detectors are used to perform radiated measurements.
Conducted emissions are measured with Line Impedance Stabilization Networks and EMI Test Receivers.
Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for making measurements.
All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference Measuring Apparatus and Measurement Methods.”
5.3 LABORATORY ACCREDITATIONS AND LISTINGS The test facilities used to perform radiated and conducted emissions tests are accredited by National Voluntary Laboratory Accreditation Program for the specific scope of accreditation under Lab Code: 200600-0 to perform Electromagnetic Interference tests according to FCC PART 15 AND CISPR 22 requirements. No part of this report may be used to claim or imply product endorsement by NVLAP or any agency of the US Government. In addition, the test facilities are listed with Federal Communications Commission (registration no: 93105 and 90471).
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 12 Rev.00
5.4 TABLE OF ACCREDITATIONS AND LISTINGS
Country Agency Scope of Accreditation Logo
USA NVLAP*
EN 55011, EN 55014-1, AS/NZS 1044, CNS 13783-1, EN 55022, CNS 13438, EN 61000-3-2, EN 61000-3-3, ANSI C63.4, FCC OST/MP-5, AS/NZS CISPR 22, IEC 61000-4-2/3/4/5/6/8/11
200600-0
USA FCC 3/10 meter Open Area Test Sites to perform FCC Part 15/18 measurements
93105, 90471
Japan VCCI 4 3/10 meter Open Area Test Sites to perform conducted/radiated measurements
R-393/1066/725/879 C-402/747/912
Norway NEMKO
EN 50081-1/2, EN 50082-1/2, IEC 61000-6-1/2, EN 50091-2, EN 50130-4, EN 55011, EN 55013, EN 55014-1/2, EN 55015, EN 55022, EN 55024, EN 61000-3-2/3, EN 61326-1, IEC 61000-4-2/3/4/5/6/8/11, EN 60601-1-2, EN 300 328-2, EN 300 422-2, EN 301 419-1, EN 301 489-01/03/07/08/09/17, EN 301 419-2/3, EN 300 454-2, EN 301 357-2
ELA 124a ELA 124b ELA 124c
Taiwan CNLA
EN 300 328-1/2, EN 300 220-1/2/3, EN 300 440-1/2, EN 61000-3-2, EN 61000-3-3, 47 CFR FCC Part 15 Subpart C/D/E, EN 55013, CNS 13439, EN 55014-1, CNS 13783-1, EN 55022, CNS 13438, CISPR 22, AS/NZS 3548, EN 61000-4-2/3/4/5/6/8/11, ENV 50204, IEEE Std 1528, FCC OET Bulletin,65+Supplement C, EN50360, EN50361, EN50371, RSS102
Taiwan BSMI CNS 13438, CNS 13783-1, CNS 13439, CNS 14115
SL2-IS-E-0014 SL2-IN-E-0014 SL2-A1-E-0014 SL2-R1-E-0014 SL2-R2-E-0014 SL2-L1-E-0014
Canada Industry Canada RSS212, Issue 1
IC 3991-3 IC 3991-4
* No part of this report may be used to claim or imply product endorsement by NVLAP or any agency of the US Government.
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 13 Rev.00
6. SETUP OF EQUIPMENT UNDER TEST
6.1 SETUP CONFIGURATION OF EUT See test photographs attached in Appendix 1 for the actual connections between EUT and support equipment.
6.2 SUPPORT EQUIPMENT
No. Device Type Brand Model Series No. FCC ID Data Cable Power Cord
1. LCD Monitor BenQ FP557 99L4672AC132500150TP1AC1 FCC DoC
Shielded, 1.8m with two cores Unshielded, 1.8m
2. USB Keyboard Compaq KU-9978 B463AOAGALT097 FCC DoC Shielded, 1.8m N/A
3. USB Mouse HP MO19UCA 020440964 FCC DoC Shielded, 1.8m N/A
4. Printer EPSON STYLUS C60 DR3K039633 FCC DoC Shielded, 1.8m Unshielded, 1.8m
5. USB 2.0 HDD TeraSyS F12-U A0100214-31d0014 FCC DoC Shielded, 1.8m Unshielded, 1.8m
6. Notebook PC IBM 2656 AK-VF0HT FCC DoC
Shielded, 1.8m with two cores Unshielded, 1.8m
7. Notebook PC Toshiba Satellite 1110 Y2382109 FCC DoC
Shielded, 1.8m with two cores Unshielded, 1.8m
Notes: 1. All the equipment/cables were placed in the worst-case configuration to maximize the
emission during the test. 2. Grounding was established in accordance with the manufacturer’s requirements and
conditions for the intended use.
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 14 Rev.00
6.3 TEST SETUP The equipment under test was configured and operated in a manner to communicate with Bluetooth USB Hub continuously. EUT tends to maximize its emission characteristics in a typical application for conducted and radiated emission measurement. The RF module plus ancillary (stand alone unit) was evaluated as per table 2 of clause 7.1 of ETSI Final draft ETSI EN 301 489-1 V1.4.1: 20002. The transmitter was active during the conducted and radiated emission measurements.
Software Used During the Test
Operating System Windows XP
Program Sequence 1. Boot up Windows XP. 2. Connect and link the auxiliary bluetooth dongle.
RF Management Software S/W provided applicant.
Remark: During the test, no modification is made to the EUT to comply with Class B limit levels.
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 15 Rev.00
7. ETSI EN 301 489-1/-17 REQUIREMENTS
7.1 RADIATED EMISSION
LIMIT Please refer to ETSI EN 301 489-1 Clause 8.2.3, Table 4 and EN 55022 Clause 6, Table 6, Class B
Test Configuration
Filter Filter Filter To Power
EUT
Ground Plane10 m
0.8 m
CoaxialCable
Turntable 1m ~ 4m
Power Cable
EMI Receiver
Filter
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 16 Rev.00
TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 8.2.3 and EN 55022 Clause 6 for the measurement methods.
TEST RESULTS No non-compliance noted
Test Data
Location: Site # 3 Tested by: Tom Jen
Test Mode: Mod 2 Test Distance: 10m
Detector Function: Quasi-peak Test Results: Passed
Freq. (MHz)
Ant. V/H
Reading (dBuV)
Factor (dB)
Actual FS(dBuV/m)
Limits(QP)(dBuV/m)
Safe Margins
(dB) Note
66.00 V 15.80 9.67 25.47 30.00 -4.53 Peak
226.65 V 7.61 16.29 23.90 30.00 -6.10 Peak
240.15 V 11.05 16.50 27.55 37.00 -9.45 Peak
N/A
240.15 H 12.24 16.50 28.74 37.00 -8.26 Peak
249.15 H 12.60 16.64 29.24 37.00 -7.76 Peak
280.65 H 7.89 16.48 24.37 37.00 -12.63 Peak
N/A
Note:
1. Measuring frequencies from 30 MHz to the 1GHz. 2. Radiated emissions measured in frequency range from 30 MHz to 1000MHz were made
with an instrument using Peak detector mode. 3. Field strength limits for frequency above 1000MHz are based on average limits.
However, Peak mode field strength shall not exceed the average limits specified plus 20dB.
4. Measurements above show only up to 6 maximum emissions noted. 5. The IF bandwidth of SPA 30MHz to 1GHz was 100kHz.
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 17 Rev.00
7.2 AC MAINS LINE CONDUCTED EMISSION
LIMIT Please refer to ETSI EN 301 489-1 Clause 8.4.3, Table 8 and EN 55022 Clause 5, Table 2, Class B
Test Configuration
E U T
LISN
EM I receiver
R eference ground plane
V ert. reference plane
TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 8.4.3 and EN 55022 Clause 5 for the measurement methods.
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 18 Rev.00
TEST RESULTS No non-compliance noted
Test Data
Operation Mode: TX + RX mode Test Date: November 12, 2004
Temperature: 25oC Tested by: Tom Jen
Humidity: 55% RH
Freq. (MHz)
QP Reading
AV Reading
Corr. factor
QP Result
AV Result QP Limit AV Limit QP
Margin AV
Margin Note
0.194 43.710 36.060 0.076 43.786 36.136 63.864 53.864 -20.077 -17.727 L1
0.302 39.470 36.240 0.090 39.560 36.330 60.188 50.188 -20.628 -13.858 L1
0.541 49.940 38.860 0.110 50.050 38.970 56.000 46.000 -5.950 -7.030 L1
1.259 42.720 29.260 0.118 42.838 29.378 56.000 46.000 -13.162 -16.622 L1
3.328 41.290 29.780 0.207 41.497 29.987 56.000 46.000 -14.503 -16.013 L1
9.605 31.070 26.670 0.360 31.430 27.030 60.000 50.000 -28.570 -22.970 L1
0.192 40.350 38.020 0.067 40.417 38.087 63.950 53.950 -23.533 -15.863 L2
0.305 34.030 32.000 0.090 34.120 32.090 60.106 50.106 -25.986 -18.016 L2
0.563 41.720 34.900 0.129 41.849 35.029 56.000 46.000 -14.151 -10.971 L2
1.269 37.150 36.150 0.125 37.275 36.275 56.000 46.000 -18.725 -9.725 L2
3.302 35.840 33.390 0.179 36.019 33.569 56.000 46.000 -19.981 -12.431 L2
6.983 28.480 26.230 0.309 28.789 26.539 60.000 50.000 -31.211 -23.461 L2
Remark:
1. The measuring frequencies range between 0.15 MHz and 30 MHz. 2. The emissions measured in the frequency range between 0.15 MHz and 30MHz were made
with an instrument using Quasi-peak detector and Average detector. 3. “---” denotes the emission level was or more than 2dB below the Average limit, and no
re-check was made. 4. The IF bandwidth of SPA between 0.15MHz and 30MHz was 10kHz. The IF bandwidth of
Test Receiver between 0.15MHz and 30MHz was 9kHz. 5. L1 = Line One (Live Line) / L2 = Line Two (Neutral Line)
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 19 Rev.00
Test Plot
Conducted emissions (Line 1)
Conducted emissions (Line 2)
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 20 Rev.00
7.3 AC MAINS HARMONIC CURRENT EMISSION
LIMIT Please refer to EN 61000-3-2
Test Configuration
Ambient Condition of the Test Site Temperature 25°C EUT AC Voltage Rating 230 Vac, 50 Hz
Humidity 55%RH EUT DC Voltage Rating N/A
Tested by Tom Jen Ground Bond Resistance 0.2 Ω
TEST PROCEDURE Please refer to EN 61000-3-2 for the measurement methods.
TEST RESULTS No non-compliance noted.
Note: According to clause 7 of EN 61000-3-2, equipment with a rated power of 75W or less, no limits apply. The test result is only for reference.
Harmonics & Flicker
Analyzer +
Power Source EUT
Support Units
Power Cord
0.8m
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 21 Rev.00
Harmonic Emission - IEC 61000-3-2, EN 61000-3-2, (EN60555-2)
Comply: IEC 61000-3-2 Ed.2.1: 2001 (incl. Amd.14) - IEC 61000-4-7 Ed.1.0: 1991 MICRO-STAR HARCS Setup File : unnamed HARCS Report File : unnamed Bluetooth USB Hub ms-6781 Tom Remarks Temp : 25'C Humidity : 55% RH
Full Bar : Actual Values Empty Bar : Maximum Values Blue : Current , Green : Voltage , Red : Failed
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 22 Rev.00
7.4 AC MAINS VOLTAGE FLUCTUATION AND FLICKER
LIMIT Please refer to EN 61000-3-3
Test Configuration
(Same as the configuration of the AC MAINS HARMONIC CURRENT EMISSIONS TEST)
Ambient Condition of the Test Site Temperature 25°C EUT AC Voltage Rating 230 Vac, 50 Hz
Humidity 55%RH EUT DC Voltage Rating N/A
Tested by Tom Jen Ground Bond Resistance 0.2 Ω
TEST PROCEDURE Please refer to EN 61000-3-3 for the measurement methods.
TEST RESULTS No non-compliance noted.
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 23 Rev.00
Flicker Emission - IEC 61000-3-3, EN 61000-3-3, (EN60555-3)
Comply: IEC 61000-3-3 Ed.1.1: 2002 (incl. Amd.1) - IEC 61000-4-15 Ed.1.0: 1997
(incl. Amd.1)
MICRO-STAR HARCS Setup File: unnamed HARCS Report File: unnamed Bluetooth USB Hub
ms-6781
Tom
Remarks
Full Bar : Actual Values
Empty Bar : Maximum Values
Circles : Average Values
Blue : Current , Green : Voltage , Red : Failed
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 24 Rev.00
7.5 ELECTROSTATIC DISCHARGE
LIMIT Please refer to EN 61000-4-2
Test Configuration
Ambient Condition of the Test Site Temperature 28°C EUT AC Voltage Rating 230 Vac, 50 Hz
Humidity 40%RH EUT DC Voltage Rating N/A
Pressure 1019 mbar Ground Bond Resistance 0.2 Ω
Tested by Tom Jen
Ground Reference Plane
Wooden Table
Indirect Support units
EUT & its direct
Support Units
VCP
HCP >1m
0.8m
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 25 Rev.00
TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.3.2 and EN 61000-4-2 for the measurement methods.
TEST RESULTS PASS (System will be recovered itself after the temporary service suspension which caused by
the interference applied.)
Description of the Electrostatic Discharges (ESD)
Operating Mode
Amount of Discharges Voltage Coupling Result (Pass/Fail)
Mini 20 / Point ±4kV Contact Discharge Pass
Mini 20 / Point ±8kV Air Discharge Pass
Mini 20 / Point ±4kV Indirect Discharge HCP Pass
Mini 20 / Point ±4kV Indirect Discharge VCP Pass
Note: For tested points to EUT, refer to the enclosed pages. Be aware that the Blue mark is for contact discharge, and the red mark is for air discharge.
PERFORMANCE CRITERIA
Criteria requested A / B / C Criteria meet A / B / C
Standby Mode
Amount of Discharges Voltage Coupling Result (Pass/Fail)
Mini 20 / Point ±4kV Contact Discharge Pass
Mini 20 / Point ±8kV Air Discharge Pass
Mini 20 / Point ±4kV Indirect Discharge HCP Pass
Mini 20 / Point ±4kV Indirect Discharge VCP Pass
Note: For tested points to EUT, refer to the enclosed pages. Be aware that the Blue mark is for contact discharge, and the red mark is for air discharge.
PERFORMANCE CRITERIA
Criteria requested A / B / C Criteria meet A / B / C
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 26 Rev.00
The Tested Points of EUT
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 27 Rev.00
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 28 Rev.00
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 29 Rev.00
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 30 Rev.00
7.6 RF ELECTROMAGNETIC FIELD LIMIT Please refer to EN 61000-4-3
Test Configuration
0.8m
Power Amp Signal Generator
EUT Monitoring by using a camera
Control Room
7x3x3
EUT & Support Units
PC Controller to control S.G. & PA as well as forward power
3 meter
1.5 meter
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 31 Rev.00
Ambient Condition of the Test Site Temperature 23°C EUT AC Voltage Rating 230 Vac, 50 Hz
Humidity 40%RH EUT DC Voltage Rating N/A
Pressure 1019 mbar Ground Bond Resistance 0.2 Ω
Tested by Tom Jen
TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.2.2, ETSI EN 301 489-17 Clause 7.2 and EN 61000-4-3 for the measurement methods.
TEST RESULTS PASS (EUT continued to operate normally during test)
Description of Preliminary Test (Operating & Standby Modes)
Freq. Range (MHz) Field Modulation Polarity Position (°) Selection for
the final test1 80-2000 6V/m Yes H / V Front
2 80-2000 6V/m Yes H / V Right
3 80-2000 6V/m Yes H / V Back
4 80-2000 6V/m Yes H / V Left
Result of Final Tests (Operating Mode)
Freq. Range (MHz) Field Modulation Polarity Position (°) Result
(Pass/Fail) 80-2000 3V/m Yes H / V Front Pass
PERFORMANCE CRITERIA
Criteria requested A / B / C
Criteria meet A / B / C
Results of Final Tests (Standby Mode)
Freq. Range (MHz) Field Modulation Polarity Position (°) Result
(Pass/Fail)
80-2000 3V/m Yes H / V Front Pass PERFORMANCE CRITERIA Criteria requested A / B / C
Criteria meet A / B / C
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 32 Rev.00
7.7 AC MAINS FAST TRANSIENTS – COMMON MODE
LIMIT Please refer to EN 61000-4-4
Test Configuration
Ambient Condition of the Test Site Temperature 23°C EUT AC Voltage Rating 230 Vac, 50 Hz
Humidity 40%RH EUT DC Voltage Rating N/A
Pressure 1019 mbar Ground Bond Resistance 0.2 Ω
Tested by Tom Jen
Controller Computer
EFT/Burst/ Surge Generator
EUTSupport Units
0.8m Non-Conductive Table AC Line
Injection Clamp Burst Generator
To Load
AC Line
Comm. Line ≧ 3 mEUT
0.8m Non-Conductive
Table
10cm
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 33 Rev.00
TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.4.2 and EN 61000-4-4 for the measurement methods.
TEST RESULTS PASS (EUT continued to operate normally during test)
TEST CONDITIONS Results of Final Tests (Operating Mode)
Impulse Frequency: 5 kHz Tr/Th: 5/50ns Burst Duration: 15ms Burst Period: 3Hz
Injection Line Voltage (kV) Injected Method Result (Pass / Fail) Line ±1 Direct Pass Neutral ±1 Direct Pass PE ± 1 Direct Pass Line + Neutral ±1 Direct Pass L + PE ± 1 Direct Pass N + PE ± 1 Direct Pass L + N + PE ± 1 Direct Pass RJ45 port (LAN cable) ±0.5 Clamp Pass RJ11 port (Line cable) ±0.5 Clamp Pass
PERFORMANCE CRITERIA Criteria requested A / B / C Criteria meet A / B / C
Results of Final Tests (Standby Mode) Impulse Frequency: 5 kHz Tr/Th: 5/50ns Burst Duration: 15ms Burst Period: 3Hz
Injection Line Voltage (kV) Injected Method Result (Pass / Fail) Line ±1 Direct Pass Neutral ±1 Direct Pass PE ± 1 Direct Pass Line + Neutral ±1 Direct Pass L + PE ± 1 Direct Pass N + PE ± 1 Direct Pass L + N + PE ± 1 Direct Pass RJ45 port (LAN cable) ±0.5 Clamp Pass RJ11 port (Line cable) ±0.5 Clamp Pass
PERFORMANCE CRITERIA Criteria requested A / B / C Criteria meet A / B / C
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 34 Rev.00
7.8 AC MAINS SURGE
LIMIT Please refer to EN 61000-4-5
Test Configuration
Ambient Condition of the Test Site
Temperature 23°C EUT AC Voltage Rating 230 Vac, 50 Hz Humidity 40%RH EUT DC Voltage Rating N/A Pressure 1019 mbar Ground Bond Resistance 0.2 Ω Tested by Tom Jen
TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.8.2 and EN 61000-4-5 for the measurement methods.
Surge Immunity Test
Controller Computer
EUT &
Support Units
0.8m
To AC Source
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 35 Rev.00
TEST RESULTS PASS (EUT continued to operate normally during test)
Test conditions
Results of Final Tests (Operating Mode) Voltage Waveform: 1.2/50 us Current Waveform: 8/20 us Polarity: Positive/Negative Phase angle: 0o, 90o, 180 o, 270o
Coupling Line Voltage (kV) Polarity Coupling Method Result (Pass/Fail)
Line + Neutral 1 Pos./ Neg. Capacitive Pass
L + PE 1 Pos./ Neg. Capacitive Pass
N + PE 1 Pos./ Neg. Capacitive Pass
T, R-Ground 0.5 Pos./ Neg. Capacitive Pass
L1, 2, 3, 4-G (LAN) 0.5 Pos./ Neg. Capacitive Pass
PERFORMANCE CRITERIA
Criteria requested A / B / C Criteria meet A / B / C
Results of Final Tests (Standby Mode) Voltage Waveform: 1.2/50 us Current Waveform: 8/20 us Polarity: Positive/Negative Phase angle: 0o, 90o, 180 o, 270o
Coupling Line Voltage (kV) Polarity Coupling Method Result (Pass/Fail)
Line + Neutral 1 Pos./ Neg. Capacitive Pass
L + PE 1 Pos./ Neg. Capacitive Pass
N + PE 1 Pos./ Neg. Capacitive Pass
T, R-Ground 0.5 Pos./ Neg. Capacitive Pass
L1, 2, 3, 4-G (LAN) 0.5 Pos./ Neg. Capacitive Pass PERFORMANCE CRITERIA Criteria requested A / B / C
Criteria meet A / B / C
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 36 Rev.00
CDN
EUT and Support units Power
Amplifier PC Controller
Ground Reference Plane
10 cm isolation supporter
0.1m< L <0.3m
7.9 AC MAINS RF – COMMON MODE
LIMIT
Please refer to EN 61000-4-6
Test Configuration
Ambient Condition of the Test Site
Temperature 23°C EUT AC Voltage Rating 230 Vac, 50 Hz
Humidity 40%RH EUT DC Voltage Rating N/A
Pressure 1019 mbar Ground Bond Resistance 0.2 Ω
Tested by Tom Jen
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 37 Rev.00
TEST PROCEDURE Please refer to ETSIETSI EN 301 489-1 Clause 9.5.2, ETSI EN 301 489-17 Clause 7.2.2 and EN 61000-4-6 for the measurement methods.
TEST RESULTS PASS (EUT continued to operate normally during test)
TEST CONDITIONS
Results of Final Tests (Operating Mode) Frequency Range: 0.15MHz~80MHz Frequency Step: 1% of fundamental Dwell time: 3 Sec.
80% A.M., 1 kHz Sine wave (Field Strength: 3 V/m) Coupling type: CDN: FCC-801-M3-16A / RF Current Probe
Range (MHz) Field Modulation Result (Pass/Fail)
0.15-80 3V/m Yes Pass
PERFORMANCE CRITERIA
Criteria requested A / B / C Criteria meet A / B / C
Results of Final Tests (Standby Mode) Frequency Range: 0.15MHz~80MHz Frequency Step: 1% of fundamental Dwell time: 3 Sec.
80% A.M., 1 kHz Sine wave (Field Strength: 3 V/m) Coupling type: CDN: FCC-801-M3-16A / RF Current Probe
Range (MHz) Field Modulation Result (Pass/Fail)
0.15-80 3V/m Yes Pass
PERFORMANCE CRITERIA Criteria requested A / B / C Criteria meet A / B / C
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 38 Rev.00
7.10 VOLTAGE DIPS AND INTERRUPTION
LIMIT Please refer to EN 61000-4-11
Test Configuration
Ambient Condition of the Test Site
Temperature 23°C EUT AC Voltage Rating 230 Vac, 50 Hz
Humidity 40%RH EUT DC Voltage Rating N/A
Pressure 1019 mbar Ground Bond Resistance 0.2 Ω
Tested by Tom Jen
TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.7.2 and EN 61000-4-11 for the measurement methods.
Dips/Interruption and Variations
Simulator
Controller Computer
EUT &
Support Units
0.8m
To AC Source
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 39 Rev.00
TEST RESULTS PASS (for criteria A: EUT continued to operate normally during test) (for criteria B: EUT shut down, but can be auto recovered as the events disappear.) (for criteria C: EUT shut down, but can be recovered by manual, as the events disappear.)
TEST CONDITIONS Interruption at phase angles of 0, 45, 90, 135, 180, 225, 270 and 315 degree in a 10 sec-interval.
Test Level (% UT)
Reduction (%)
Duration (ms) Criterion
70 30% 10 B Voltage Dips 40 60% 100 C
Voltage Interruption <5 >95% 5000 C
Note: The duration with a sequence of three dips/interruptions with a minimum interval of 10 s between each test event.
Results of Final Tests (Operating Mode) Voltage Dips
Test Level (% UT)
Reduction (%)
Duration (ms) Observation Criterion
70 30 10 Normal A
40 60 100 Normal B
Voltage Interruption
Test Level (% UT)
Reduction (%)
Duration (ms) Observation Criterion
<5 95 5000 Normal C
Results of Final Tests (Standby Mode) Voltage Dips
Test Level (% UT)
Reduction (%)
Duration (ms) Observation Criterion
70 30 10 Normal A
40 60 100 Normal B
Voltage Interruption
Test Level (% UT)
Reduction (%)
Duration (ms) Observation Criterion
<5 95 5000 Normal C
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 40 Rev.00
APPENDIX 1 PHOTOGRAPHS OF TEST SETUP RADIATED EMISSION TEST (EN 55022)
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 41 Rev.00
LINE CONDUCTED EMISSION TEST (EN 55022)
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 42 Rev.00
POWER HARMONICS &VOLTAGE FLUCTUATION / FLICKER (EN 61000-3-2/EN 61000-3-3)
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 43 Rev.00
ELECTROSTATIC DISCHARGE TEST (EN 61000-4-2)
RADIATED ELECTROMAGNETIC FIELD (EN 61000-4-3)
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 44 Rev.00
FAST TRANSIENTS/BURST TEST (EN 61000-4-4)
SURGE IMMUNITY TEST (EN 61000-4-5)
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004
Page 45 Rev.00
CONDUCTED DISTURBANCE, INDUCED BY RADIO-FREQUENCY FIELDS TEST (EN 61000-4-6)
VOLTAGE DIPS/ INTERRUPTION TEST (EN 61000-4-11)