4.2 architectural plans - vancouver · 50 acton ostry architects inc rezoning application cambie...
TRANSCRIPT
48 ACTON OSTRY ARCHITECTS INC Rezoning Application | Cambie & 49th
4.2 architectural plans
level 1 - commercial and residential plan
W49TH SRW 3.6m [11'10"]
L355.47 sq m
CRU3108.77 sq m
LW1246.83 sq m
LW1146.22 sq m
LW746.03 sq m
LW1046.22 sq m
LW946.22 sq m
LW846.22 sq m
L 1181.11 sq m
UP DN
CRU683.6 sq m
CRU5192.35 sq m
L 263.36 sq m
DO1
15.9 sq m
6383CAMBIESTREET
LW148.84 sq m
commercialclass B
2.7m x 8.5m
LW262.22 sq m
LW362.9 sq m
LW462.9 sq m
LW562.9 sq m
LW663.45 sq m
residentialclass B
2.7m x 8.5m
LOADINGBAY 2
LOADINGBAY 3
3 BR 3 BR 3 BR 3 BR 3 BR
CAMBIE STREET
WES
T 4
9th
AV
ENU
E
3 BR 3 BR 3 BR 3 BR 3 BR3 BR
COURTYARD
SERVICE CORRIDOR
PARKING ACCESSRAMP DN TO P1
STAIR 2 EXIT CORRIDOR
PARKING EXIT3 BR
[2 level Live/Work]UP
water entry closet
[2 level + rooftopLive/Work]
utility pole
utility pole
CRU169 sq m
CRU4157.11 sq m
CRU2108.77 sq m
2148
6
4189
7013
1180041983
7115
75170
344743254
1139
4470
5946 4550
6097 9997
770
5954
9000 1000855
769
17390600042780
3242
[10
'-8"]
SRW
MAILROOM
TOWNHOUSES
BB/A202 AA/A201
el. 76.56
el. 76.76m
existing curb, boulevard and sidewalk derived from survey dated 6 June 2018. New street geometrics TBC by CoV
existing sidewalk
AMENITY SPACE
road dedication
existing property line
new bike lane TBC (existing sidewalk)
COMMERCIALRETAIL
SERVICE AREAel. 76.76m
CRU7107.6 sq m
new bike lane TBC (existing blvd.)
new boulevard
el. 77.4m el. 77.07mel. 77.4m el. 77.07m
DN
UP
PE3
GARBAGE /RECYCLING
9238
35'-0
"ty
p. c
ru d
epth
1635
LANE
commercialclass A
2.7m x 5.5m
LOADINGBAY 1
RESIDENTIALLOBBY 1
AMAZONDROP OFF
el. 76.56m
UP
PE1 PE2
UP DN
el. 76.56m
COMMERCIALRETAIL
COMMERCIALRETAIL
COMMERCIALRETAIL
COMMERCIALRETAIL
COMMERCIALRETAIL
COMMERCIALRETAIL
COMMERCIALRETAIL
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
CC
/A20
3D
D/A
204
el. 76.29m
refer to level Mezzanine
RAM
P D
N 1
0%R
AMP
DN
15.
5%
EL 76.7
8m
DG 77.39m
6100
610
el. 78.49m el. 78.49m el. 77.9m el. 77.9m el. 77.69m el. 77.69m
el. 76.76m
el. 78.00m
el. 77.4m el. 77.07m
RESIDENTIALLOBBY 2
DN DN
el. 76.56mUP
UP
CHILD CARE /OFFICE LOBBY
[2 level Live/Work]
[2 level + rooftopLive/Work]
[2 level Live/Work]
[2 level + rooftopLive/Work]
[2 level Live/Work]
[2 level + rooftopLive/Work]
[2 level Live/Work]
[2 level + rooftopLive/Work]
[2 level Live/Work]
[2 level + rooftopLive/Work]
elec.riser
PE4
el. 76.88m
UP
UP
86.67m
39.6
4m
39.6
5m
85.47m
UP
el. 77.4m el. 77.4m el. 77.4m el. 77.4m el. 77.4m el. 77.4m
OFFICE/ CHILD CAREENTRY
RESIDENTIALENTRY
DECK DECK DECK DECK DECK DECK
DECK DECK DECK DECK DECK DECK
RESIDENTIALENTRY
el. 77.4m
[253.44']DG 77.25m
[253.20']DG 77.17m
[253.98']DG 77.41m
[257.22']DG 78.40m
DG 77.40m
[253.94']
DG 77.40m
[253.94']
DG 77.07m
[252.85']
DG 77.07m
[252.85']
[252.26']DG 76.89m
[250.30']DG 76.29m
[255.91']DG 78.00m
[255.91']DG 78.00m
[254.89']DG 77.69m
[255.58']DG 77.90m
[257.51']DG 78.49m
DG 76.48m
[250.92']
DG 76.56m
[251.18']
DG 76.57m
[251.21']
DG 76.57m
[251.21']
DG 76.07m
[249.57']
DG 113.18m
[371.32']
roof parapet
basesurface EL.
DG 116.07m
[380.81']
EL.
DG 76.24m
[250.13']
basesurface
mechanical P
H
parapet
[252.79']DG 77.05m
BG 76.03m
[249.44']
[249.41']BG 76.02m
[251.61']BG 76.69m
[252.20']BG 76.87m
[252.82']BG 77.06m
BG 77.13m
[253.05']
BG 77.32m
[253.67']
BG 77.45m
[254.10']
[254.86']BG 77.68m
[258.14']BG 78.68m
[256.73']BG 78.25m
[255.68']BG 77.93m
[254.92']BG 77.70m
[253.90']BG 77.39m
[252.49']BG 76.96m
[249.87']BG 76.16m
[252.17']BG 76.86m
[251.90']BG 76.78m
[252.17']BG 76.86m
[251.61']BG 76.69m
[251.05']BG 76.52m
BG 76.16m
[249.87']
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A111
Level 1 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
49ACTON OSTRY ARCHITECTS INC Rezoning Application | Cambie & 49th
4.2architectural plans
level 1 - mezzanine plan
UP DN
LW10 - L248.93 sq m
LW12 - L249.98 sq m
LW11 - L248.93 sq m
LW9 - L248.93 sq m
LW8 - L248.93 sq m
LW7 - L248.74 sq m
M01306.58 sq m
LW1 - L264.05 sq m
LW2 - L263.74 sq m
LW3 - L263.74 sq m
LW4 - L263.74 sq m
LW5 - L263.74 sq m
LW6 - L264.29 sq m
3 BR 3 BR 3 BR 3 BR 3 BR3 BR
RESIDENTIALAMENITY
STO
RA
GE
DN
DN
3 BR 3 BR 3 BR 3 BR 3 BR3 BR
OPEN TO BELOW
OPEN TO BELOW
PARKING ACCESSRAMP DN TO P1
OPEN TO BELOW
OPEN TO BELOW
el. 80.18
el. 80.84
utility pole
utility pole
OPEN TOBELOW
PE4
OPEN TOBELOW
OPEN TO BELOW
OPEN TO BELOW
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
CC
/A20
3
el. 79.63
UP
UP
2163
7
4189
7013
1180041983
7115
75170
344743105
1288
4470
5946 4551
6097 9997
770
5954
9000 1000
769
17391599542785
3100
UP
DN
PE3
DD
/A20
4
PE1 PE2
6383CAMBIESTREET
el. 81.43 el. 80.64el. 80.84el. 81.43 el. 80.64
[2 level Live/Work]
[2 level + rooftopLive/Work]
[2 level Live/Work]
[2 level + rooftopLive/Work]
[2 level Live/Work]
[2 level + rooftopLive/Work]
[2 level Live/Work]
[2 level + rooftopLive/Work]
[2 level Live/Work]
[2 level + rooftopLive/Work]
[2 level Live/Work]
[2 level + rooftopLive/Work]
elec.riser
BB/A202 AA/A201
OTB
el. 78.33
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A112
Level 1 Mezz. Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
90777.71 sq m
90877.71 sq m
M0158.47 sq m
90953.14 sq m
90476.54 sq m
90190.97 sq m
90690.29 sq m
90593.18 sq m
90267.43 sq m
90367.43 sq m
PROPERTY LINE
Urban Agriculture
CC
/A20
3
BRIDGE
2BR + 2 BATH
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
2009
8
75743
254461273
4267 565825285 1000600344455 2441
1829
3533
1600
5
12917
42776 277235954 6003 3016
3358 2437
AMENITY
el. 105.99el. 105.99
BA
LCO
NY
BA
LCO
NY
2BR + 2BATH 2BR + 2BATH
2BR + 2BATH2BR + 2BATH2BR + 2BATH
2BR COMPACT2BR COMPACT
PE1 PE2
UP
UP
1BR + DEN
BALCONY
BALCONY BALCONY
BALCONY
outdoordining/BBQ
Urban Agriculture
gamesUP
DN
PE3
DD
/A20
4
6383CAMBIESTREET
RESIDENTIALCORRIDOR
elec.riser
lounging/firepit
games
Trellis/climbing
vines
BB/A202 AA/A201
line of deck below
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A118
Level 9 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
90777.71 sq m
90877.71 sq m
M0158.47 sq m
90953.14 sq m
90476.54 sq m
90190.97 sq m
90690.29 sq m
90593.18 sq m
90267.43 sq m
90367.43 sq m
PROPERTY LINE
Urban Agriculture
CC
/A20
3
BRIDGE
2BR + 2 BATH
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
2009
8
75743
254461273
4267 565825285 1000600344455 2441
1829
3533
1600
5
12917
42776 277235954 6003 3016
3358 2437
AMENITY
el. 105.99el. 105.99
BA
LCO
NY
BA
LCO
NY
2BR + 2BATH 2BR + 2BATH
2BR + 2BATH2BR + 2BATH2BR + 2BATH
2BR COMPACT2BR COMPACT
PE1 PE2
UP
UP
1BR + DEN
BALCONY
BALCONY BALCONY
BALCONY
outdoordining/BBQ
Urban Agriculture
gamesUP
DN
PE3
DD
/A20
4
6383CAMBIESTREET
RESIDENTIALCORRIDOR
elec.riser
lounging/firepit
games
Trellis/climbing
vines
BB/A202 AA/A201
line of deck below
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A118
Level 9 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
50 ACTON OSTRY ARCHITECTS INC Rezoning Application | Cambie & 49th
4.2 architectural plans
level 2 - child care, office and residential plan
UP DN
LW726.54 sq m
LW826.54 sq m
LW1026.54 sq m
LW1126.54 sq m
LW1226.54 sq m
LW926.54 sq m
UP
UP
205108.24 sq m
206133.18 sq m
207191.18 sq m
204104.05 sq m
203111.34 sq m
202144.21 sq m
201472.04 sq m
Dramatic/Social
PhysicalFantasy
urbangardening
Physical
Fantasy
Dramatic/Social social
Covered Area
Preschooler
Toddler
CHILD CARE
OFFICE
wc wc
OFFICE OFFICE
OFFICE OFFICE OFFICE
balcony above
utility pole utility pole
CC
/A20
3
PE4
balcony above
roof access /stair pop-up
418.9 sq m
CHILD CAREOUTDOOR PLAY
AREA
el. 82.87
L 4
CHILD CARE /OFFICE LOBBY
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
activity room
gross motor/nap room
activity room
gross motor/nap room
quiet room
parents'room
2163
7
4189
7013
2900241983
7115
75170
375931274
3364
5946 4551
770
5954
1000
769
26393600342775
3100
el. 82.87
PE1 PE2
UP
DN
PE3
sharedstaff room
cubbies cubbies
vestibule
quiet roomsharedoffice
storage storage
sharedstaff wc/shower
sharedkitchen
TODDLERDAYCARE
(12 children)
PRESCHOOLERDAYCARE
(25 children)
Storage
deck deck deck deck deck deck
DD
/A20
4
6383CAMBIESTREET
el. 83.79el. 84.38 el. 83.58el. 83.79el. 84.38 el. 83.58
OFFICE CORRIDOR
elec.riser
BB/A202 AA/A201
42.39 sq m
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A113
Level 2 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
51ACTON OSTRY ARCHITECTS INC Rezoning Application | Cambie & 49th
4.2architectural plans
level 3 - office plan
1940
470
13
41983
9348
76502
254461273
3508 5658
27727
770
5954
25286 1000
6796
600345213
3100
12917
3012
3358 2437
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
305130.15 sq m
306133.68 sq m
307191.18 sq m
304133.53 sq m
303111.34 sq m
302144.21 sq m
OFFICE OFFICE OFFICE
OFFICE OFFICE OFFICE
301463.42 sq m
LW roof access / stairpop-up below
line of L2 outdoorplay area below
CC
/A20
3
el. 86.67
LW ROOF
el. 86.89el. 87.48 el. 86.68
PE1 PE2
UP
UP
OFFICE
OFFICE CORRIDOR
UP
DN
PE3
BALCONY
BALCONY
BALCONY
BALCONY BALCONY
BA
LCO
NY
BA
LCO
NY
DD
/A20
4
6383CAMBIESTREET
el. 86.89el. 87.48 el. 86.68
elec.riser
PE4
BB/A202 AA/A201
dn
line of L2canopy below
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A114
Level 3 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
90777.71 sq m
90877.71 sq m
M0158.47 sq m
90953.14 sq m
90476.54 sq m
90190.97 sq m
90690.29 sq m
90593.18 sq m
90267.43 sq m
90367.43 sq m
PROPERTY LINE
Urban Agriculture
CC
/A20
3
BRIDGE
2BR + 2 BATH
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
2009
8
75743
254461273
4267 565825285 1000600344455 2441
1829
3533
1600
5
12917
42776 277235954 6003 3016
3358 2437
AMENITY
el. 105.99el. 105.99
BA
LCO
NY
BA
LCO
NY
2BR + 2BATH 2BR + 2BATH
2BR + 2BATH2BR + 2BATH2BR + 2BATH
2BR COMPACT2BR COMPACT
PE1 PE2
UP
UP
1BR + DEN
BALCONY
BALCONY BALCONY
BALCONY
outdoordining/BBQ
Urban Agriculture
gamesUP
DN
PE3
DD
/A20
4
6383CAMBIESTREET
RESIDENTIALCORRIDOR
elec.riser
lounging/firepit
games
Trellis/climbing
vines
BB/A202 AA/A201
line of deck below
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A118
Level 9 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
90777.71 sq m
90877.71 sq m
M0158.47 sq m
90953.14 sq m
90476.54 sq m
90190.97 sq m
90690.29 sq m
90593.18 sq m
90267.43 sq m
90367.43 sq m
PROPERTY LINE
Urban Agriculture
CC
/A20
3
BRIDGE
2BR + 2 BATH
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
2009
8
75743
254461273
4267 565825285 1000600344455 2441
1829
3533
1600
5
12917
42776 277235954 6003 3016
3358 2437
AMENITY
el. 105.99el. 105.99
BA
LCO
NY
BA
LCO
NY
2BR + 2BATH 2BR + 2BATH
2BR + 2BATH2BR + 2BATH2BR + 2BATH
2BR COMPACT2BR COMPACT
PE1 PE2
UP
UP
1BR + DEN
BALCONY
BALCONY BALCONY
BALCONY
outdoordining/BBQ
Urban Agriculture
gamesUP
DN
PE3
DD
/A20
4
6383CAMBIESTREET
RESIDENTIALCORRIDOR
elec.riser
lounging/firepit
games
Trellis/climbing
vines
BB/A202 AA/A201
line of deck below
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A118
Level 9 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
52 ACTON OSTRY ARCHITECTS INC Rezoning Application | Cambie & 49th
4.2 architectural plans
level 4–6 - residential plan
41782.7 sq m
40247.25 sq m
42353.14 sq m
40380 sq m
40479.75 sq m
40579.75 sq m
40777.13 sq m
40883.1 sq m
40645.18 sq m
40176.24 sq m
42177.71 sq m
42277.71 sq m
40948.65 sq m
41041.64 sq m
41148.65 sq m
41241.64 sq m
41348.65 sq m
41441.64 sq m
41549.2 sq m
42041.64 sq m
41948.65 sq m
41841.64 sq m
41749.2 sq m
41647.25 sq m
PE1 PE2
UP
UP
roof access / stairpop-up below
line of L2 outdoorplay area below
CC
/A20
3
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
2433
315
303
41983
7519
76502
254461273
3508 5658
27723
770
5954
25286 1000
6796
600345213 2441
1829
1940
318
29
1829
1272
7013
12917
3358 2437
3016
1BR + 1 BATH2BR + 2BATH 2BR + 2 BATH 2BR + 2 BATH 2BR + 2 BATH
1BR + DEN
2BR + 2BATH
RESIDENTIALCORRIDOR
BALCONYBALCONYBALCONY
BALCONY
2BR + 2BATH
2BR + 2BATH
2BR + 2 BATH
BALCONY
BALCONY
STUDIO
BALCONY
BALCONY BALCONY
BALCONYBALCONYBALCONYBALCONYBALCONYBALCONY
UP
DN
PE3
STUDIO STUDIO1BR + 1 BATH1BR + 1 BATH1BR + 1 BATH1BR + 1 BATHSTUDIO1BR + 1 BATHSTUDIO1BR + 1 BATHSTUDIO1BR + 1 BATH
BALCONY BALCONY
BA
LCO
NY
BA
LCO
NY
BULK STORAGE
el. 90.93 (4)el. 93.88 (5)el. 96.82 (6)
2BR + 2BATH
DD
/A20
4
LEVEL 04 VARIATION
elevatoroverrun
6383CAMBIESTREET
BALCONYBALCONYBALCONYBALCONY
elec.riser
BB/A202 AA/A201
typ. studio area: 34.91 smarea to inside face of wall excluding storage
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A115
Level 4-6 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
53ACTON OSTRY ARCHITECTS INC Rezoning Application | Cambie & 49th
4.2architectural plans
level 7 - residential plan
71477.71 sq m
71577.71 sq m
71653.14 sq m
70577.04 sq m
70659.47 sq m
70297.9 sq m
70177.8 sq m
71341.64 sq m
71248.65 sq m
71141.64 sq m
71051.5 sq m
70379.75 sq m
70479.75 sq m
70997.9 sq m
70879.75 sq m
70779.75 sq m
2BR + 2 BATH 3BR + 2 BATH
DEC
K
DEC
K CC
/A20
3
1BR + 1BATH
BA
LCO
NY
BA
LCO
NY
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
3497
6
42776
80010
254461273
59465658
277235954
25286 1000
6003
600342775 2441
4660
1784
418
29
3016
18292437
12917
1530
315
59
1829
3358 2437
DEC
K
DEC
K
DEC
K
DECK
2BR + 2BATH 2BR + 2BATH
2BR + 2BATH
2BR + 2 BATH 2BR + 2 BATH
3BR + 2 BATH2BR + 2 BATH 2BR + 2 BATH
PE1 PE2
UP
UP
1BR + DEN
STUDIO STUDIO1BR + 1 BATH1BR + 1 BATH
BALCONY BALCONY
el. 99.77
BULK STORAGE
UP
DN
PE3
DECK
DD
/A20
4
6383CAMBIESTREET
BALCONYBALCONYBALCONYBALCONY
RESIDENTIALCORRIDOR
elec.riser
BB/A202 AA/A201
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A116
Level 7 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
90777.71 sq m
90877.71 sq m
M0158.47 sq m
90953.14 sq m
90476.54 sq m
90190.97 sq m
90690.29 sq m
90593.18 sq m
90267.43 sq m
90367.43 sq m
PROPERTY LINE
Urban Agriculture
CC
/A20
3
BRIDGE
2BR + 2 BATH
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
2009
8
75743
254461273
4267 565825285 1000600344455 2441
1829
3533
1600
5
12917
42776 277235954 6003 3016
3358 2437
AMENITY
el. 105.99el. 105.99
BA
LCO
NY
BA
LCO
NY
2BR + 2BATH 2BR + 2BATH
2BR + 2BATH2BR + 2BATH2BR + 2BATH
2BR COMPACT2BR COMPACT
PE1 PE2
UP
UP
1BR + DEN
BALCONY
BALCONY BALCONY
BALCONY
outdoordining/BBQ
Urban Agriculture
gamesUP
DN
PE3
DD
/A20
4
6383CAMBIESTREET
RESIDENTIALCORRIDOR
elec.riser
lounging/firepit
games
Trellis/climbing
vines
BB/A202 AA/A201
line of deck below
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A118
Level 9 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
90777.71 sq m
90877.71 sq m
M0158.47 sq m
90953.14 sq m
90476.54 sq m
90190.97 sq m
90690.29 sq m
90593.18 sq m
90267.43 sq m
90367.43 sq m
PROPERTY LINE
Urban Agriculture
CC
/A20
3
BRIDGE
2BR + 2 BATH
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
2009
8
75743
254461273
4267 565825285 1000600344455 2441
1829
3533
1600
5
12917
42776 277235954 6003 3016
3358 2437
AMENITY
el. 105.99el. 105.99
BA
LCO
NY
BA
LCO
NY
2BR + 2BATH 2BR + 2BATH
2BR + 2BATH2BR + 2BATH2BR + 2BATH
2BR COMPACT2BR COMPACT
PE1 PE2
UP
UP
1BR + DEN
BALCONY
BALCONY BALCONY
BALCONY
outdoordining/BBQ
Urban Agriculture
gamesUP
DN
PE3
DD
/A20
4
6383CAMBIESTREET
RESIDENTIALCORRIDOR
elec.riser
lounging/firepit
games
Trellis/climbing
vines
BB/A202 AA/A201
line of deck below
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A118
Level 9 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
54 ACTON OSTRY ARCHITECTS INC Rezoning Application | Cambie & 49th
4.2 architectural plans
level 8 - residential plan
81477.71 sq m
81577.71 sq m
81653.14 sq m
80577.04 sq m
80659.47 sq m
80297.9 sq m
80177.8 sq m
81341.64 sq m
81248.65 sq m
81141.64 sq m
81051.5 sq m
80379.75 sq m
80479.75 sq m
80997.9 sq m
80879.75 sq m
80779.75 sq m
2BR + 2 BATH 3BR + 2 BATH
1BR + 1BATH
BA
LCO
NY
BA
LCO
NY
2BR + 2BATH 2BR + 2BATH
2BR + 2BATH
BULK STORAGE
2BR + 2 BATH 2BR + 2 BATH
3BR + 2 BATH2BR + 2 BATH 2BR + 2 BATH
BALCONY
1BR + DEN
STUDIO STUDIO1BR + 1 BATH1BR + 1 BATH
BALCONY BALCONY
CC
/A20
3
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
el. 102.72
BALCONY
BALCONY BALCONY BALCONYBALCONY
BALCONYBALCONYBALCONY
line of deck below
PE1 PE2
UP
UP
UP
DN
PE3
DD
/A20
4
6383CAMBIESTREET
BALCONYBALCONYBALCONYBALCONY
RESIDENTIALCORRIDOR
elec.riser
BB/A202 AA/A201
3497
6
42776
80010
254461273
59465658
277235954
25286 1000
6003
600342775 2441
4660
1784
418
29
3016
1829
3358
2437
12917
2437
1530
318
29
1829
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A117
Level 8 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
55ACTON OSTRY ARCHITECTS INC Rezoning Application | Cambie & 49th
4.2architectural plans
level 9 - residential plan
90777.71 sq m
90877.71 sq m
M0158.47 sq m
90953.14 sq m
90476.54 sq m
90190.97 sq m
90690.29 sq m
90593.18 sq m
90267.43 sq m
90367.43 sq m
PROPERTY LINE
Urban Agriculture
CC
/A20
3
BRIDGE
2BR + 2 BATH
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
2009
8
75743
254461273
4267 565825285 1000600344455 2441
1829
3533
1600
5
12917
42776 277235954 6003 3016
3358 2437
AMENITY
el. 105.99el. 105.99
BA
LCO
NY
BA
LCO
NY
2BR + 2BATH 2BR + 2BATH
2BR + 2BATH2BR + 2BATH2BR + 2BATH
2BR COMPACT2BR COMPACT
PE1 PE2
UP
UP
1BR + DEN
BALCONY
BALCONY BALCONY
BALCONY
outdoordining/BBQ
Urban Agriculture
gamesUP
DN
PE3
DD
/A20
4
6383CAMBIESTREET
RESIDENTIALCORRIDOR
elec.riser
lounging/firepit
games
Trellis/climbing
vines
BB/A202 AA/A201
line of deck below
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A118
Level 9 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
90777.71 sq m
90877.71 sq m
M0158.47 sq m
90953.14 sq m
90476.54 sq m
90190.97 sq m
90690.29 sq m
90593.18 sq m
90267.43 sq m
90367.43 sq m
PROPERTY LINE
Urban Agriculture
CC
/A20
3
BRIDGE
2BR + 2 BATH
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
2009
8
75743
254461273
4267 565825285 1000600344455 2441
1829
3533
1600
5
12917
42776 277235954 6003 3016
3358 2437
AMENITY
el. 105.99el. 105.99
BA
LCO
NY
BA
LCO
NY
2BR + 2BATH 2BR + 2BATH
2BR + 2BATH2BR + 2BATH2BR + 2BATH
2BR COMPACT2BR COMPACT
PE1 PE2
UP
UP
1BR + DEN
BALCONY
BALCONY BALCONY
BALCONY
outdoordining/BBQ
Urban Agriculture
gamesUP
DN
PE3
DD
/A20
4
6383CAMBIESTREET
RESIDENTIALCORRIDOR
elec.riser
lounging/firepit
games
Trellis/climbing
vines
BB/A202 AA/A201
line of deck below
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A118
Level 9 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
90777.71 sq m
90877.71 sq m
M0158.47 sq m
90953.14 sq m
90476.54 sq m
90190.97 sq m
90690.29 sq m
90593.18 sq m
90267.43 sq m
90367.43 sq m
PROPERTY LINE
Urban Agriculture
CC
/A20
3
BRIDGE
2BR + 2 BATH
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
2009
8
75743
254461273
4267 565825285 1000600344455 2441
1829
3533
1600
5
12917
42776 277235954 6003 3016
3358 2437
AMENITY
el. 105.99el. 105.99
BA
LCO
NY
BA
LCO
NY
2BR + 2BATH 2BR + 2BATH
2BR + 2BATH2BR + 2BATH2BR + 2BATH
2BR COMPACT2BR COMPACT
PE1 PE2
UP
UP
1BR + DEN
BALCONY
BALCONY BALCONY
BALCONY
outdoordining/BBQ
Urban Agriculture
gamesUP
DN
PE3
DD
/A20
4
6383CAMBIESTREET
RESIDENTIALCORRIDOR
elec.riser
lounging/firepit
games
Trellis/climbing
vines
BB/A202 AA/A201
line of deck below
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A118
Level 9 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
56 ACTON OSTRY ARCHITECTS INC Rezoning Application | Cambie & 49th
4.2 architectural plans
level 10 - residential plan
100477.71 sq m
100577.71 sq m
100653.14 sq m
100390.29 sq m
100293.18 sq m
2BR + 2BATH
2BR + 2BATH2BR + 2BATH2BR + 2BATH
1BR + DEN
1001103.69 sq m
2544512917
2007
2
75743
1273
4267 565825285 1000600344455 2441
3533
1603
0
PROPERTY LINE
CC
/A20
3
BALCONY
BALCONY BALCONY
BALCONY
3BR + 2 BATH
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
BA
LCO
NY
BA
LCO
NY
ROOF
ROOF
el. 109.27el. 109.24
el. 109.24
PE1 PE2
UP
UP
DD
/A20
4
6383CAMBIESTREET elec.
riser
BB/A202 AA/A201
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A119
Level 10 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
57ACTON OSTRY ARCHITECTS INC Rezoning Application | Cambie & 49th
4.2architectural plans
roof plan
PROPERTY LINE
CC
/A20
3
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
MECHANICAL
2544912913
1000
1272
5658249881000
ELEV. OVERRUN
el. 112.876383
CAMBIESTREET
el. 112.87
BB/A202 AA/A201
DG 76.07m
[249.57']
DG 113.18m
[371.32']
roof parapet
basesurface EL.
DG 116.07m
[380.81']
EL.
DG 76.24m
[250.13']
basesurface
mechanical P
H
parapet
DD
/A20
4
dn
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A121
Roof Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
90777.71 sq m
90877.71 sq m
M0158.47 sq m
90953.14 sq m
90476.54 sq m
90190.97 sq m
90690.29 sq m
90593.18 sq m
90267.43 sq m
90367.43 sq m
PROPERTY LINE
Urban Agriculture
CC
/A20
3
BRIDGE
2BR + 2 BATH
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
2009
8
75743
254461273
4267 565825285 1000600344455 2441
1829
3533
1600
5
12917
42776 277235954 6003 3016
3358 2437
AMENITY
el. 105.99el. 105.99
BA
LCO
NY
BA
LCO
NY
2BR + 2BATH 2BR + 2BATH
2BR + 2BATH2BR + 2BATH2BR + 2BATH
2BR COMPACT2BR COMPACT
PE1 PE2
UP
UP
1BR + DEN
BALCONY
BALCONY BALCONY
BALCONY
outdoordining/BBQ
Urban Agriculture
gamesUP
DN
PE3
DD
/A20
4
6383CAMBIESTREET
RESIDENTIALCORRIDOR
elec.riser
lounging/firepit
games
Trellis/climbing
vines
BB/A202 AA/A201
line of deck below
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A118
Level 9 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning
90777.71 sq m
90877.71 sq m
M0158.47 sq m
90953.14 sq m
90476.54 sq m
90190.97 sq m
90690.29 sq m
90593.18 sq m
90267.43 sq m
90367.43 sq m
PROPERTY LINE
Urban Agriculture
CC
/A20
3
BRIDGE
2BR + 2 BATH
DED
ICAT
ION
1m
[3'-3
"]
PROPERTY LINE
PRO
PER
TY L
INE
PROPERTY LINE
PRO
PER
TY L
INE
2009
8
75743
254461273
4267 565825285 1000600344455 2441
1829
3533
1600
5
12917
42776 277235954 6003 3016
3358 2437
AMENITY
el. 105.99el. 105.99
BA
LCO
NY
BA
LCO
NY
2BR + 2BATH 2BR + 2BATH
2BR + 2BATH2BR + 2BATH2BR + 2BATH
2BR COMPACT2BR COMPACT
PE1 PE2
UP
UP
1BR + DEN
BALCONY
BALCONY BALCONY
BALCONY
outdoordining/BBQ
Urban Agriculture
gamesUP
DN
PE3
DD
/A20
4
6383CAMBIESTREET
RESIDENTIALCORRIDOR
elec.riser
lounging/firepit
games
Trellis/climbing
vines
BB/A202 AA/A201
line of deck below
key3 bed2bed1bedstudioresidential amenitycommercial retail / officechildcarelandscapingcirculationstorage / service / garbageparking
pedestrian entrancevehicle entrance
All drawings and related documents are the property of Acton Ostry Architects Inc and may not be reproduced in whole or in part without the Architect's permission. This drawing should not be used to calculate areas. Do not scale this drawing. All dimensions to be checked on site by the contractor and such dimensions to be their responsibility. All work must comply with the relevant Building Code or Building Bylaw and related documents. Drawing errors and omissions must be immediately reported to the Architect.
111 E 8 AvenueVancouver BCCanada V5T 1R8t 604.739.3344f [email protected]
Cambie & 49thGryphon Development6409, 6435, 6459, 6487 Cambie Street, Vancouver BC
scale date
project code status
drawn checked
1:200 06 Dec 2019
C49 Rezoning
IK MF MO
A118
Level 9 Plandrawing number
issues
06 Dec 2019 Issued for Rezoning