  • TMITA2 UPS

    5-20kVACompact, Efficient & Robust UPSFor Critical Applications

  • VertivYour Vision, our Passion

    Vertiv, formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable vital applications for data centers, communication networks, and commercial & industrial environments.

    We support today's growing mobile and cloud computing markets with our portfolio of power, thermal and infrastructure management products, software and solutions, all complemented by our extensive global service network.

    We help strengthen the world's most vital applications by bringing together global reach and local knowledge, and our decades-long heritage, including brands like ASCO, Chloride, Liebert, NetSure, and Trellis.

    With a unique combination of industry expertise, technology, and resources, our mission is to support and power mission-critical technologies that drive possibility.

    Our industry-leading software gives customers an integrated view of operations across IT and facilities resources, enabling better decisions that save time and money

    Our global power and thermal management solutions are some of the world’s most efficient and reliable power and cooling technologies

    Our global industrial power solutions meet the most demanding technical specifications and provide safe, reliable power- no matter the challenge

    Our global critical power switching, control, and management solutions, engineered to the most demanding specifications, ensures power, reliability, compliance and efficiency

    Our global intelligently engineered DC power systems deliver high availability, energy efficiency, and scalability for converged networks

    Co & ne suci ltv ar te ioS ntwaf ro eS

    franI s td re uif ci tn urU e

    ThermalManagement

    PowerManagement

    IT Management

    WE ARE VERTIV

  • In today's dynamic world, it is not enough for enterprises to have basic power protection. With digital trends constantly emerging and transforming the way you do business, business continuity is all the more vital. You simply cannot afford downtime in your critical system or waste time recovering these systems after a disruption. What you need is a robust, high-speed, reliable UPS system, which offers

    perennial, round-the-clock protection to diverse

    application needs.

    The Liebert® ITA2TM is a fully-digital, highly reliable, double-conversion UPS solution that delivers clean and consistent power.

    This highly efficient solution is ideal for various deployments, whether it's IT racks, network closets, automation control systems, and precision instruments to small-sized control rooms among other edge applications.

    Ÿ Cutting –edge design enables seamless integration into various ecosystems

    Ÿ Tailored for global deployment in a low carbon, compact footprint

    .

    The ultimate level of engineering and dynamics that have gone beyond the development of this next-generation, innovative product facilitate top-notch availability and excellent performance at a low cost of ownership, giving you ultimate peace of mind.

    Our Solution

    Application Areas

    5-10kVA

    16-20kVA

    TM ®Liebert ITA2 5-20kVA

    Ÿ Edge Networks

    Ÿ Data Centers

    Ÿ Automation industries

    Ÿ Server Farms

    Ÿ Workstations

    Ÿ Telecom

  • TM Liebert ITA2 5-20kVA

    Key Features

    Ÿ Robust structure with cutting-edge channelized airflow design

    Ÿ Wide input voltage range, making it immune to grid interference

    Ÿ Programmable output outlets/ terminals with cascade protection to protect key devices during heavy load

    Ÿ Integrated Ethernet port with HTTP protocol compatibility & streamlined remote monitoring

    Ÿ Easy to install, repair, and maintain

    Ÿ Compliance with seismic conduction & vehicle carrying test

    Ÿ Gravity sense LCD Display

    TM ® Liebert ITA2 offers best-in-class efficiency of up to 96.3% over a wide range of load conditions, resulting in significant OPEX cost savings.

    TMITA2 's integrated Smart Sleep technology in ECO mode provides a superlative efficiency of up to 99%.

    70605040

    3020

    100

    2Sp

    ace/

    inch

    ®Liebert ITA2 Brand A Brand B

    The Most Efficient UPS

    The Most Compact UPS

  • TM ®Available in different wattage variations, Liebert ITA2is ideal in edge of networks, light industrial applications and data centers, blending easily into any virtualized environment and providing comprehensive power protection at lower operating costs.

    Reliability in a Compact Footprint:

    Ÿ Fully-digital control with high output voltage precision.

    Ÿ Manages all the nine power problems including sagging, spikes, and fluctuations.

    Ÿ Built-in Ethernet port includes compatibility with intelligent cards (SIC card, RDU_SIC cards, etc.,) with browser support.

    Ÿ Built-in-power charger for fast charging reduces battery charging time.

    Ÿ Prolonged backup time through cascaded connection.

    Ÿ Quality-tested for 1000 hours for extreme durability and extreme tolerance even in stringent condition

    High Availability

    Early Warning of UPS System Status: Multiple audible and visual alarms immediately alert you to critical issues.

    Periodic Battery TestingProvides automatic and manual self-diagnostic battery testing for peace of mind.

    Power-Factor CorrectionPrevents noise, harmonics, and distortion from being passed on to connected loads or from being fed back to the utility.

    Lightning and Surge ProtectionThe transient voltage surge suppression circuitry inside

    TM ®the Liebert ITA2 provides additional protection for the connected equipment.

    Wide Input Voltage WindowProlongs battery life by allowing the UPS to maximize the use of utility power before transferring to the battery when the input voltage exceeds the specified limits.

    Dust-Proof Design

  • Model

    Model

    Model

    Model

    Battery Backup Table

    Model Number

    Model Number

    Model Number

    Model Number

    Backup Time

    Backup Time

    Backup Time

    Backup Time

    5kVA

    10kVA

    16kVA

    20kVA

    4.5kVA

    9kVA

    14.4kVA

    18kVA

    4kVA

    8kVA

    12.8kVA

    16kVA

    3.5kVA

    7kVA

    11.2kVA

    14kVA

    3kVA

    6kVA

    9.6kVA

    12kVA

    2.5kVA

    5kVA

    8kVA

    10kVA

    2kVA

    4kVA

    6.4kVA

    8kVA

    1.5kVA

    3kVA

    4.8kVA

    6kVA

    1kVA

    2kVA

    3.2kVA

    4kVA

    0.5kVA

    1kVA

    1.6kVA

    2kVA

    5kVA

    10kVA

    16kVA

    20kVA

    123456

    23456

    4681012

    4681012

    5.515.027.039.551.563.5

    4.08.012.518.023.5

    7.514.021.028.535.5

    5.510.015.021.027.0

    6.517.531.045.058.071.5

    4.59.515.021.027.0

    9.016.024.533.041.5

    6.511.517.524.531.5

    7.520.536.051.566.581.5

    6.011.518.025.032.0

    10.519.028.538.548.0

    7.514.021.028.536.5

    9.525.042.560.077.094.5

    8.014.522.030.038.5

    13.024.534.045.556.0

    9.517.025.534.043.0

    11.530.551.071.591.5111.5

    11.521.031.041.551.5

    16.028.541.554.567.0

    11.521.031.041.552.0

    15.039.063.087.0111.5139.5

    15.027.039.551.563.5

    21.036.552.067.082.0

    15.027.039.552.064.0

    20.551.080.5104.0146.0181.5

    20.536.051.566.581.5

    28.548.067.086.0105.0

    21.036.552.067.082.0

    30.070.0110.0156.5203.5250.5

    30.551.071.591.5111.5

    41.566.592.0118.5148.5

    31.051.572.092.5112.5

    49.5108.0177.0246.5316.0386.0

    51.080.5110.5146.0181.5

    145.0233.5322.0410.5498.5

    51.581.5112.0148.0184.0

    103.5235.0368.5502.0635.5768.5

    108.0177.0246.5316.0386.0

    108.0177.0246.5316.0386.0

    111.0181.5252.5324.0395.0

    POD-Optional Accessories

    When your critical system can not afford any power loss without power, even for scheduled UPS maintenance, the Liebert POD Maintenance Bypass and Output Distribution Unit ensures continuous uptime.

    It allows you to manually transfer connected equipment to utility power via a maintenancebypass switch, permitting scheduled service or UPS replacement without the need to shut down connected equipment.

    Features include:

    Ÿ 2U height minimizes rack space requirements

    Ÿ Easy plug-and-play installation

    POD

    ITA2 UPS

    Battery module

    Isometric view of ITA2 UPS installed in rack-mounted alignment along with POD and Battery modules

  • Input frequency range(Hz)

    Nominal output frequency (Hz)

    Voltage harmonic distortion(%)

    Crestfactor

    Overload capacity

    Rated power factor(kW/kVA)

    Nominal output voltage (V)

    Battery Charger max. power (A)

    5

    Nominal input frequency(Hz)

    DC Bus Voltage

    Nominal Ratings(kVA)

    Dimensions and weight

    Nosie at 1 m(dBA)

    Dimensions (W x D x H) in mm

    220/230/240VAC1-Phase, 2Wire

    220/230/240VAC 1-Phase, 2Wire380/400/415VAC 3-Phase,4Wire

    380/400/415VAC 3-Phase,4Wire

    Input voltage range(V)

    Nominal input voltage(V)

    UPS classification according toIEC 62040-3

    General and safety requirements for UPS

    10 16

    Input power factor(kW/kVA)

    Current THD at full linear load(THDi%)

    Input parameters

    Weight(kg)

    General

    176-288VAC at full load; 100-176VAC at linear derating; 100VAC at half load

    50/60

    40-70

    0.99

    140-240VDC

    = 5A (Long back-up model)

    = 2A (Standard model)

    = 8A (Long back-up model)

    = 4A (Standard model)

    = 13A (Long back-up model)

    = 5A (Standard model)

    140-240VDC 288-480VDC

  • Tel: +852-2690-4118www.turnkeytech.com.hk

    Enquiries: [email protected]