5-optix rtn 600 configuration

30
Page 1 Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 1 Contents Configuration Operations 2.5.1 Logging In to an NE 2.5.2 Modifying the NE ID 2.5.3 Configuring IF Protection 2.5.4 Setting IF Attributes 2.5.5 Setting RF Attributes 2.5.7 Configuring Service 2.5.7 Configuring SNCP Service 2.5.8 Converting service 2.5.9 Alarm 2.5.10 Performance 2.5.11 Communications and Security

Upload: waleed-mohamed-alhassn

Post on 24-Apr-2017

302 views

Category:

Documents


23 download

TRANSCRIPT

Page 1Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 1

Contents Configuration Operations

2.5.1 Logging In to an NE 2.5.2 Modifying the NE ID 2.5.3 Configuring IF Protection 2.5.4 Setting IF Attributes 2.5.5 Setting RF Attributes 2.5.7 Configuring Service 2.5.7 Configuring SNCP Service 2.5.8 Converting service 2.5.9 Alarm 2.5.10 Performance 2.5.11 Communications and

Security

Page 2Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 2

Web LCT Configuration – Logging In to an NEStep1 Double-click the T2000 Web LCT shortcut icon on the desktop to

launch the T2000 Web LCT.Step2 The User Login screen is displayed. Enter the user name and

password. Click Login.

Page 3Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 3

Web LCT Configuration – Logging In to an NE

Create an NE in one of the following two ways.1. Click NE Search and specify the search criteria. Select the NE to

be added to create a new NE.

Page 4Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 4

Web LCT Configuration – Logging In to an NE

2. Create an NE directly. Click the “Add NE” and Enter the information of the NE and create the NE.

Page 5Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 5

Web LCT Configuration – Logging In to an NE Step 4: In the NE List, select the target NE and click NE Login.Then, the

IE displays the NE Login dialog box.

• Step 5:Enter the User Name and the Password. Then, click OK.

Page 6Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 6

Web LCT Configuration – Modifying the NE ID Step 1 In the NE Explorer, choose Configuration > NE Attribute

from the Function Tree. Click Modify NE ID.

Page 7Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 7

Web LCT Configuration – Modifying the NE ID

Step 2 Enter a new ID and click OK.

Page 8Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 8

Web LCT Configuration – Modifying the NE ID Step 3 In the NE list, delete the original NE. Create a new NE with

the new ID.

Page 9Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 9

Web LCT Configuration – Configuring IF Protection The supported IF protection is 1+1 HSB, 1+1 SD, and 1+1 FD.

Create IF protection

Step 1 In the NE Explorer, choose Configuration > IF 1+1 Protection from the Function Tree.

Page 10Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 10

Web LCT Configuration – Configuring IF Protection

Step 2 Click New and enter the information of the IF protection. Click OK or Apply.

Page 11Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 11

Web LCT Configuration – Configuring IF Protection Perform IF protection external switching. The priorities of external

switching commands are as follows: clear, lockout, force, and manual.

Page 12Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 12

Web LCT Configuration – Setting IF Attributes You can set the following IF attributes by using the T2000 Web LCT:

working mode, link ID, IF port loopback, 2 Mbit/s wayside service, and ATPC-related information.

In the NE Explorer, select an IF board and choose IF Interface from the Function Tree.

Page 13Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 13

Web LCT Configuration – Setting IF Attributes• You can enable automatic transmit power control (ATPC), and adjust the threshold and the ATPC adjustment.

Page 14Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 14

Web LCT Configuration – Setting RF Attributes By using the T2000 Web LCT, you can query and configure the

following RF attributes: transmit frequency, T/R spacing, transmitted power, ODU manufacturer information, RF loopback status, and ODU status.

Frequency attributes

Page 15Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 15

Web LCT Configuration – Setting RF AttributesPower attributes

Page 16Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 16

Web LCT Configuration – Setting RF AttributesODU manufacturer information

Page 17Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 17

Web LCT Configuration – Setting RF AttributesIn the Advanced Attributes tab, you set RF loopback and ODU status.

Page 18Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 18

Web LCT Configuration – Configuring a Service

This operation is applicable to VC4, VC3, and VC12 services. Procedure

Step 1 In the NE Explorer, Configuration -> Cross-Connection Configuration from the Function Tree.

Page 19Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 19

Web LCT Configuration – Configuring a Service

Page 20Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 20

Web LCT Configuration – Configuring a ServiceStep 2 Click New, enter the information of a service and click OK or Apply.

Page 21Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 21

Web LCT Configuration – Configuring an SNCP Service

This operation is applicable to VC12, VC3, and VC4 SNCP services. Procedure Step 1 In the Cross-Connection Configuration window, click

Create SNCP. Enter the information of an SNCP service.

Page 22Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 22

Web LCT Configuration – Configuring an SNCP Service

Step 2 After you create an SNCP service, the window is divided into two panes. The upper pane displays the working service and the lower pane displays the protection service. You can perform external switching for the working and protection services.

Page 23Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 23

Web LCT Configuration – Converting a Service The T2000 Web LCT supports the conversion between a normal

service and an SNCP service. To convert a normal service to an SNCP service, select a normal

service, right-click and choose Convert to SNCP from the shortcut menu. Enter the source of the service in the protection channel and click OK.

Page 24Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 24

Web LCT Configuration – Converting a Service You can convert the working or protection channel of an SNCP service to

a normal service. To convert a working channel, right-click the service in the working

channel and choose SNCP Working Service Change to Normal Service from the shortcut menu.

Page 25Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 25

Web LCT Configuration – Converting a Service To convert a protection channel, right-click the service in the protection

channel and choose SNCP Protection Service Change to Normal Service from the shortcut menu.

Page 26Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 26

Web LCT Configuration – Alarm By using the T2000 Web LCT, you can view the current and history alarms,

the reporting status of alarms for an NE and boards, and abnormal events.

Page 27Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 27

Web LCT Configuration – Performance The T2000 Web LCT supports 15-minute and 24-hour

performance monitoring intervals.

Page 28Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 28

You can view the current and history performance data, UAT events, threshold crossings, and performance monitoring status. You can set the performance threshold and reset a board registry.

Web LCT Configuration – Performance

Page 29Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 29

Web LCT Configuration – Communications

The RTN 600 uses the OSP NE platform. You can set multiple protocol stacks, including the OSI, IP,

and HWECC.

Page 30Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 30

Web LCT Configuration – Communications For DCC management, an IF board supports the configuration of

different DCC rates in different working modes. When the working mode is PDH, the configuration of one-

byte DCC (D1-D1) rate is supported. When the working mode is SDH, the configuration of D1-D3,

D4-D12, D1-D12, and D1-D1 is supported.