51 overview - propertyproperty.mq.edu.au/documents/mq_guideline_part07_internalsigns... · 51...
TRANSCRIPT
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
01. EXECUTIVE SUMMARY
5.1 OVERVIEW
Part Seven Signage Design - Internal A
MACQUARIE UNIVERSITYSIGNAGE AND WAYFINDING GUIDELINES
Part Seven / Issue ThreeSignage Design – Internal
07
HEADING
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
HEADING
B Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 001001
HEADING
.00107 SECTION SEVEN: SIGNAGE DESIGN – INTERNAL
SIGN PLACEMENT 002
ENTRY SERIES 004
DIRECTIONAL SERIES 023
VENUE/DESTINATION SERIES 037
INFORMATION SERIES 049
SPECIAL ROOMS SERIES 053
AMENITY SERIES 066
ROOM SERIES 080
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
CONTENTS
01 INTRODUCTION
02 WAYFINDING PRINCIPLES
03 DESIGN ELEMENTS
04 NAMING STRATEGY – EXTERNAL
05 NAMING STRATEGY – INTERNAL
06 SIGNAGE DESIGN – EXTERNAL
07 SIGNAGE DESIGN – INTERNAL >
08 CONSTRUCTION DETAILS
09 SPECIFICATION
APPENDIX 1 ROLLOUT PLANNING SIGN LOCATION OVERVIEW BULK QUANTITIES
APPENDIX 2 SUSTAINABILITY
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
002 Part Seven Signage Design - Internal
SIGN TYPES IN DETAIL INTERNAL SIGNS
SIGN PLACEMENT
FRONT ELEVATION
Scale 1:25
00000-00000Lecture Theatre 1
Toilets
12≤Rooms 000-000
Lecture Theatre 1
Toilets
00000
Mr John MooreFaculty of Business and Economics
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
1 University Avenue
32" screen
Accessible touch zone
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Ground00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00000 IEC Head of Department
00000-00000Lecture Theatre 1
≤Rooms 000-000
Lecture Theatre 1
Toilets
<Rooms 000-000
Lecture Theatre 2
Unisex and accessible toilets
>Rooms 000-000
Lecture Theatre 2
LiftandStairs
00000-00000Lecture Theatre 2
00000-00000Lecture Theatre 3
Unisex Toilets
Unisex Toilets
12Ground00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00.000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
1 University Avenue
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
10
1000mm1000mm
9.7" screeniPad
2060mm
1805mm
1306mm
1213mm
2060mm
1805mm
1714mm1714mm
1213mm
1305mm
A3
Male ToiletMale Toilet
Level 300000-0000 Museum of Ancient Cultures00000-0000 Australian Centre for Ancient Numismatic Studies00000-0000 IEC Administration00000-0000 IEC Student Enquiry Office00000-0000 IEC Head of Department00000-0000 Head of Division
Level 2 00000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms
Level 1 00000 IEC Drama and Movement Room00000 Early Childhood Road Safety Education Program00000 Resource DevelopmentTeaching Rooms
Ground00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms
1 University Avenue
Lecture Theatre
G23 Lecture TheatreG23 Lecture Theatre
G23
15" screen
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.
G23 Lecture TheatreG23 Lecture Theatre
Lecture Theatre
G23
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may ocur
in this room. discussions conducted in
the room may be captured.
In Case Of Emergency Dial 9999
Femtosecond Direct Write Facility
0 2- 0 0 0
00000Contact:Name Name 0000 000 000
Hazardous substances in this area. Do not enter without approval. hazardous substances in this area. Do
not enter without approval.
Sign types have been placed at specific distances from the floor to ensure consistency across the family, and to create a neat and considered alignment of signs when viewing several in one panoramic. The datum line is a fixed measurement from which all signs are to be located. There are two measurements to be considered when installing the various sign types, the hanging line and the base line.
The diagram below illustrates this placement.
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 003
00000-00000Lecture Theatre 1
Toilets
12≤Rooms 000-000
Lecture Theatre 1
Toilets
00000
Mr John MooreFaculty of Business and Economics
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
1 University Avenue
32" screen
Accessible touch zone
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Ground00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00000 IEC Head of Department
00000-00000Lecture Theatre 1
≤Rooms 000-000
Lecture Theatre 1
Toilets
<Rooms 000-000
Lecture Theatre 2
Unisex and accessible toilets
>Rooms 000-000
Lecture Theatre 2
LiftandStairs
00000-00000Lecture Theatre 2
00000-00000Lecture Theatre 3
Unisex Toilets
Unisex Toilets
12Ground00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00.000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
1 University Avenue
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
10
1000mm1000mm
9.7" screeniPad
2060mm
1805mm
1306mm
1213mm
2060mm
1805mm
1714mm1714mm
1213mm
1305mm
A3
Male ToiletMale Toilet
Level 300000-0000 Museum of Ancient Cultures00000-0000 Australian Centre for Ancient Numismatic Studies00000-0000 IEC Administration00000-0000 IEC Student Enquiry Office00000-0000 IEC Head of Department00000-0000 Head of Division
Level 2 00000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms
Level 1 00000 IEC Drama and Movement Room00000 Early Childhood Road Safety Education Program00000 Resource DevelopmentTeaching Rooms
Ground00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms
1 University Avenue
Lecture Theatre
G23 Lecture TheatreG23 Lecture Theatre
G23
15" screen
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.
G23 Lecture TheatreG23 Lecture Theatre
Lecture Theatre
G23
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may ocur
in this room. discussions conducted in
the room may be captured.
In Case Of Emergency Dial 9999
Femtosecond Direct Write Facility
0 2- 0 0 0
00000Contact:Name Name 0000 000 000
Hazardous substances in this area. Do not enter without approval. hazardous substances in this area. Do
not enter without approval.
SIGN TYPES IN DETAIL INTERNAL SIGNS
SIGN PLACEMENT
00000-00000Lecture Theatre 1
Toilets
12≤Rooms 000-000
Lecture Theatre 1
Toilets
00000
Mr John MooreFaculty of Business and Economics
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
1 University Avenue
32" screen
Accessible touch zone
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Ground00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00000 IEC Head of Department
00000-00000Lecture Theatre 1
≤Rooms 000-000
Lecture Theatre 1
Toilets
<Rooms 000-000
Lecture Theatre 2
Unisex and accessible toilets
>Rooms 000-000
Lecture Theatre 2
LiftandStairs
00000-00000Lecture Theatre 2
00000-00000Lecture Theatre 3
Unisex Toilets
Unisex Toilets
12Ground00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00.000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
1 University Avenue
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
10
1000mm1000mm
9.7" screeniPad
2060mm
1805mm
1306mm
1213mm
2060mm
1805mm
1714mm1714mm
1213mm
1305mm
A3
Male ToiletMale Toilet
Level 300000-0000 Museum of Ancient Cultures00000-0000 Australian Centre for Ancient Numismatic Studies00000-0000 IEC Administration00000-0000 IEC Student Enquiry Office00000-0000 IEC Head of Department00000-0000 Head of Division
Level 2 00000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms
Level 1 00000 IEC Drama and Movement Room00000 Early Childhood Road Safety Education Program00000 Resource DevelopmentTeaching Rooms
Ground00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms
1 University Avenue
Lecture Theatre
G23 Lecture TheatreG23 Lecture Theatre
G23
15" screen
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.
G23 Lecture TheatreG23 Lecture Theatre
Lecture Theatre
G23
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may ocur
in this room. discussions conducted in
the room may be captured.
In Case Of Emergency Dial 9999
Femtosecond Direct Write Facility
0 2- 0 0 0
00000Contact:Name Name 0000 000 000
Hazardous substances in this area. Do not enter without approval. hazardous substances in this area. Do
not enter without approval.
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
004 Part Seven Signage Design - Internal
BUILDING ENTRANCE DOOR
Sheet 1 of 1I001
FRONT ELEVATION
Scale 1:20
SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES
FRONT ELEVATION SCALE 1:20
1Entry
Building/door entrance number.Vinyl applied to surface (white or charcoal).Ensure colour of lettering provides a sufficient amount of contrast (minimum of 30% contrast).
50
300
142
Sign use: To identify building entrance
Location: On door at building entrance
Typical content: – Entry – Door number
GRAPHIC DETAILS
ENTRY Typeface: National Bold Colour: MQ White or MQ Charcoal
Note: Indicative size only. Size to be adjusted to suit specific location.
Ensure sign colour provides required illuminance contrast from wall/glass surface.
Part Seven Signage Design - Internal 005
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ENTRY SERIES
BUILDING ENTRANCE ACCESSIBLE PANEL
Sheet 1 of 2
FRONT ELEVATION
Scale 1:20
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
I001a
FRONT ELEVATION SCALE 1:20
Entry1
Entry 1
W2
Entry 1
Aluminium two-pack polyurethane panel.Braille (white) and tactile (charcoal).
105
1350 1278
175
50 - 300mmDetermine on site
Sign use: To identify building entrance (accessible use)
Location: On wall at building entrance clear of opening doors
Typical content: – Entry – Door number
006 Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES
BUILDING ENTRANCE ACCESSIBLE PANEL
Sheet 2 of 2I001a
GRAPHIC DETAILS
Scale 1:2FRONT ELEVATION SCALE 1:2
Entry 1
W2
Entry 1
36
815
GRAPHIC DETAILS
TACTILE TYPE AND DOOR NUMBER Typeface: National Regular Colour: MQ Charcoal
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 007
FRONT ELEVATION SCALE 1:20
140 (NOM)
32" screen
Ground00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Accessible touch zone
1 University Avenue Building Name
Goes Here
525
1260
2060
697
156
1050
LCD 32" recessed screen showing interactive building map. 1250mm maximum height for touch screen controls.Access to wiring needed.Solid aluminium cover to be provided if digital screens not able to be added at time of construction.
Victorian Ash timber detail. Concealed fixtures.
Aluminium two-packpolyurethane facade.Vinyl messaging applied.
Building number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.
FRONT SIDE
Braille (white) and tactile (charcoal).
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
I002MAIN DIRECTORY - WALL MOUNTED
Sheet 1 of 5
ELEVATIONS
Scale 1:20
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ENTRY SERIES
Sign use: To identify the levels within the building and allow detailed searches for individual names/offices etc
Location: Main entrance foyer
Typical content: – Building name/street address – Faculties/departments/research centres
(National/MU/Faculty)– Key rooms/lecture theatres/teaching spaces/meeting
rooms/Deans office/faculty executive– Interactive building/level map– Braille and tactile type (only location and security number)
Note: Sign I002, I003 and I006 provide the same function – primary directory to be located at key arrival points within a building. The form varies to provide options that best suit the specific built environment the sign is located in. Whislt the primary message content is the same the graphic layout varies due to the inclusion of a screen or the position of the Tactile + Braille information. During the implementation phase the layout should be selected depending on the inclusion or otherwise of screens and the extent of message content.
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
008 Part Seven Signage Design - Internal
FRONT ELEVATION SCALE 1:20
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
1260
525
2060
697
140 (NOM)
156
1050
LCD 32" recessed screen showing interactive building map.1250mm maximum height for touch screen controls.Access to wiring needed.Solid aluminium cover to be provided if digital screens not able to be added at time of construction.
Victorian Ash timber detail. Concealed fixtures.
Aluminium two-packpolyurethane facade.Vinyl messaging applied.
DIRECTORY WITH BUILDING NAME
Building number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.
FRONT SIDE
1 University Avenue
32" screen
Accessible touch zone
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Braille (white) and tactile (charcoal).
Ground00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00000 IEC Head of Department
MAIN DIRECTORY - WALL MOUNTED
Sheet 2 of 5I002
ELEVATIONS
Scale 1:20
SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 009
MAIN DIRECTORY - WALL MOUNTED
Sheet 3 of 5I003
ELEVATIONS
Scale 1:20
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ENTRY SERIES
FRONT ELEVATION SCALE 1:20
32" screen
Ground00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
1 University Avenue S2.6
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
Accessible touch zone
1260
392 140 (NOM)
2060
697
1050
156
LCD 32" recessed screen showing interactive building map.1250mm maximum height for touch screen controls.Access to wiring needed.Solid aluminium cover to be provided if digital screens not able to be added at time of construction.
Victorian Ash timber detail. Concealed fixtures.
Aluminium two-packpolyurethane facade.Vinyl messaging applied.
Building number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.
FRONT SIDE
I002
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
010 Part Seven Signage Design - Internal
SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES
I002MAIN DIRECTORY - WALL MOUNTED
Sheet 4 of 5
GRAPHIC DETAILS
Scale 1:10
SANITARY FACILITY PICTOGRAM Height: 20mm Colour: MQ Charcoal and B21 Ultramarine
DIRECTORY TEXT Typeface: National Regular Colour: MQ Charcoal
FRONT ELEVATION SCALE 1:10
1 University Avenue
32" screen
Accessible touch zone
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Ground00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00000 IEC Head of Department
10
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
1250
315
6015
6
170
170
170
170
170
170
2420
123
321321
33
118
3838 55 55
26
DIRECTORY LAYOUT (8 LEVELS)
GRAPHIC DETAILS
BUILDING STREET ADDRESS Typeface: National Bold
TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal
LEVEL INDICATOR LINE Line height: 3mm Colour: MQ Red
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section
Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.
This sign should be integrated with tactile ground surface indicators in accordance with AS1428.41 and Part H2 of the BCA.
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 011
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ENTRY SERIES
MAIN DIRECTORY - WALL MOUNTED
Sheet 5 of 5I002
GRAPHIC DETAILS
Scale 1:10
FRONT ELEVATION SCALE 1:10
32" screen
Ground00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Accessible touch zone
1 University Avenue Building Name
Goes Here
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
1250
321321
118
257
156
138
77
315
170
170
170
170
2424
2012
3
10
33 3838 55
2665
45
170
60
216
DIRECTORY LAYOUT (4 LEVELS) WITH BUILDING NAME
SANITARY FACILITY PICTOGRAM Height: 20mm Colour: MQ Charcoal and B21 Ultramarine
DIRECTORY TEXT Typeface: National Regular Colour: MQ Charcoal
GRAPHIC DETAILS
BUILDING STREET ADDRESS Typeface: National Bold
BUILDING NAME Typeface: National Bold
TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal
LEVEL INDICATOR LINE Line height: 3mm Colour: MQ Red
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.
This sign should be integrated with tactile ground surface indicators in accordance with AS1428.41 and Part H2 of the BCA.
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
012 Part Seven Signage Design - Internal
SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES
MAIN DIRECTORY - FREESTANDING
Sheet 1 of 5I003
ELEVATIONS
Scale 1:20
FRONT ELEVATION SCALE 1:20
32" screen
Level 000000 Museum of Ancient Cultures
00000-00000 Australian Centre for Ancient
00000-00000 Numismatic Studies
00000-00000 IEC Head of Department
Level 1 00000-00000 Early Childhood Road Safety
Education Program
00000-00000 IEC Music Room
Media Teaching Rooms
Level 200000-00000 IEC Drama and Movement Room
00000-00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 4 00000-00000 Lecture Theatre
00000-00000 Mia Mia Child and Family Study Centre
00000-00000 Centre for Open Education
Teaching Rooms
Level 600000-00000 IEC Administration
00000-00000 IEC Student Enquiry Office
00000-00000 IEC Head of Department
00000-00000 Head of Division
Level 700000-00000 Early Childhood Road Safety
Education Program
00000-00000 IEC Technical Services
00000-00000 IEC Art Room
Level 3 00000-00000 IEC Drama and Movement Room
00000-00000 Resource Development
Teaching Rooms
Level 5 00000-00000 Lecture Theatre
00000-00000 Mia Mia Child and Family Study Centre
00000-00000 Centre for Open Education
Teaching Rooms
E4 Level 1Help Point
For help call 0000 0000For help and information
1260
392 140 (NOM)
2060
1350
697
700
156
LCD 32" recessed screen showing interactive building map.1250mm maximum height for touch screen controls.Access to wiring needed.Solid aluminium cover to be provided if digital screens not able to be added at time of construction.
Braille and tactile.
Victorian Ash timber detail. Concealed fixtures.
Aluminium two-packpolyurethane facade.Vinyl messaging applied.
Building number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.
FRONT SIDE
1 University Avenue
Sign use: To identify the levels within the building and allow detailed searches for individual names/offices etc
Location: Main entrance foyer
Typical content: – Building street address/building name – Faculties/departments/research centres
(National/MU/Faculty)– Key rooms/lecture theatres/teaching spaces/meeting
rooms/Deans office/faculty executive– Interactive building/level map– Braille and tactile type
Note: This sign must be integrated with tactile
ground locators as specified in AS1428.4.1 Tactile
Ground Surface Indicators.
Note: Sign I002, I003 and I006 provide the same function – primary directory to be located at key arrival points within a building. The form varies to provide options that best suit the specific built environment the sign is located in. Whislt the primary message content is the same the graphic layout varies due to the inclusion of a screen or the position of the Tactile + Braille information. During the implementation phase the layout should be selected depending on the inclusion or otherwise of screens and the extent of message content.
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 013
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ENTRY SERIES
I003MAIN DIRECTORY - FREESTANDING
Sheet 2 of 5
ELEVATIONS
Scale 1:20FRONT ELEVATION SCALE 1:20
1 University Avenue
32" screen
Accessible touch zone
Level 000000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
E4 Level 1Help Point
For help call 0000 0000For help and information
525
1260
2060
697
140 (NOM)
1350
700
156
Braille and tactile.
LCD 32" recessed screen showing interactive building map.1250mm maximum height for touch screen controls.Access to wiring needed.Solid aluminium cover to be provided if digital screens not able to be added at time of construction.
Victorian Ash timber detail. Concealed fixtures.
Aluminium two-packpolyurethane facade.Vinyl messaging applied.
Building number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.
FRONT SIDE
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
014 Part Seven Signage Design - Internal
SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES
I003MAIN DIRECTORY - FREESTANDING
Sheet 3 of 5
ELEVATIONS
Scale 1:20
FRONT ELEVATION SCALE 1:20
140 (NOM)
Victorian Ash timber detail. Concealed fixtures.
SIDE
32" screen
Level 000000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
E4 Level 1Help Point
For help call 0000 0000For help and information
1260
392
2060
1350
697
700
156
LCD 32" recessed screen showing interactive building map.1250mm maximum height for touch screen controls.Access to wiring needed.Solid aluminium cover to be provided if digital screens not able to be added at time of construction.
Braille and tactile.
Aluminium two-packpolyurethane facade.Vinyl messaging applied.
Building number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.
FRONT
1 UniversityAvenue S2.6
Part Seven Signage Design - Internal 015
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ENTRY SERIES
MAIN DIRECTORY - FREESTANDING
Sheet 4 of 5I003
GRAPHIC DETAILS
Scale 1:10
FRONT ELEVATION SCALE 1:10
32" screen
Accessible touch zone
Level 000000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
E4 Level 1Help Point
For help call 0000 0000For help and information
1250
31515
6
60
170
170
170
170
170
170
2424
2012
1212
3
321
10
321
33
118
3838 55 55
2665
4526
26
DIRECTORY LAYOUT (8 LEVELS)
1 University Avenue
SANITARY FACILITY PICTOGRAM Height: 20mm Colour: MQ Charcoal and B21 Ultramarine
DIRECTORY TEXT Typeface: National Regular Colour: MQ Charcoal
LEVEL INDICATOR LINE Line height: 3mm Colour:MQ Red
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
GRAPHIC DETAILS
BUILDING STREET ADDRESS Typeface: National Bold
TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.
This sign should be integrated with tactile ground surface indicators in accordance with AS1428.41 and Part H2 of the BCA.
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
016 Part Seven Signage Design - Internal
SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES
I003MAIN DIRECTORY - FREESTANDING
Sheet 5 of 5
GRAPHIC DETAILS
Scale 1:10
FRONT ELEVATION SCALE 1:10
32" screen
Level 000000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
E4 Level 1Help Point
For help call 0000 0000For help and information
Accessible touch zone
1250
321321
118
156
315
170
170
170
170
2424
2012
3
10
33 3838 55
2665
45
DIRECTORY LAYOUT (4 LEVELS) WITH BUILDING NAME
1561 University
Avenue
TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal
SANITARY FACILITY PICTOGRAM Height: 20mm Colour: MQ Charcoal and B21 Ultramarine
GRAPHIC DETAILS
BUILDING STREET ADDRESS Typeface: National Bold
BUILDING NAME Typeface: National Bold
DIRECTORY TEXT Typeface: National Regular Colour: MQ Charcoal
LEVEL INDICATOR LINE Line height: 3mm Colour: MQ Red
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.
This sign should be integrated with tactile ground surface indicators in accordance with AS1428.41 and Part H2 of the BCA.
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 017
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ENTRY SERIES
I004POSTER AND BROCHURE STAND
Sheet 1 of 1
ELEVATIONS
Scale 1:20
Sign use: Poster and brochure display
Location: At faculty discretion
Typical content: – N/A
FRONT ELEVATION SCALE 1:20
A3POSTER
A3POSTER
A3POSTER
A3POSTER
301260
2060
160
136
8011
568
Victorian Ash timber detail. Concealed fixtures.
Aluminium two-pack polyurethane facade (MQ White).
Flame edged clear acrylic sliding panels. Printed A3 poster insert.
FRONT SIDE
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
018 Part Seven Signage Design - Internal
HELP POINT
Sheet 1 of 2I005
ELEVATIONS
Scale 1:15
SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES
Sign use: To help and provide assistance
Location: At main entrance or a location determined by campus security
Typical content: – Building street address– Help button/intercom– Help/Information telephone number– Braille and tactile type
FRONT ELEVATION SCALE 1:15
Help PointHelp Point
Push button to callPush button to call
Help point
Hearing loopHearing loop
Building number laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.
LED light
Victorian Ash timber detail Concealed fixtures
Aluminium two-packpolyurethane facade
Help point
Aluminium two-packpolyurethane removeable panel
Tactile and Braille
140 (NOM)500
2060
1350
991
500
50
FRONT SIDE
1 University Avenue
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 019
I005HELP POINT
Sheet 2 of 2
GRAPHIC DETAILS
Scale 1:10
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ENTRY SERIES
GRAPHIC DETAILS
BUILDING STREET ADDRESS Typeface: National Bold
HELP POINT Typeface: National Regular Colour: MQ White
INFORMATION PICTOGRAM Height: 49mm Colour: MQ White
TACTILE TEXT Typeface: National Regular Colour: MQ White
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
HELP POINT PANEL BACKGROUND Colour: B21 Ultramarine
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
FRONT ELEVATION SCALE 1:10
Help PointHelp Point
Push button to callPush button to call
Help point
Hearing loopHearing loop
117
8050
6060
60
50 50
1 University Avenue
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
020 Part Seven Signage Design - Internal
SMALL DIRECTORY - WALL MOUNTED
Sheet 1 of 3I006
ELEVATIONS
Scale 1:15
SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES
Sign use: To identify the levels within the building
Location: At main entrance of small building
Typical content: – Building street address– Faculties/departments /research centres
(National/MU/Faculty)– Key rooms lecture theatres/teaching spaces/meeting
rooms– Deans office/faculty executive– Braille and tactile type
FRONT ELEVATION SCALE 1:15
Ground00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00.000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
1 University Avenue
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
10
Building number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.
Victorian Ash timber detail. Concealed fixtures.
Aluminium two-packpolyurethane facade.Vinyl messaging applied.
30854
1425
635
FRONT SIDE
1170
Braille (white) and tactile (charcoal).
Note: Sign I002, I003 and I006 provide the same function – primary directory to be located at key arrival points within a building. The form varies to provide options that best suit the specific built environment the sign is located in. Whislt the primary message content is the same the graphic layout varies due to the inclusion of a screen or the position of the Tactile + Braille information. During the implementation phase the layout should be selected depending on the inclusion or otherwise of screens and the extent of message content.
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 021
I006SMALL DIRECTORY - WALL MOUNTED
Sheet 2 of 3
GRAPHIC DETAILS
Scale 1:10
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ENTRY SERIES
GRAPHIC DETAILS
BUILDING STREET ADDRESS Typeface: National Bold
DIRECTORY TEXT Typeface: National Regular Colour: MQ Charcoal
LEVEL INDICATOR LINE Line height: 3mm Colour: MQ Red
TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
FRONT ELEVATION SCALE 1:10
Ground00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00.000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
1 University AvenueGround00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00.000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
Level 600000 IEC Administration
00000 IEC Student Enquiry Office
00000 IEC Head of Department
00000 Head of Division
Level 700000 Early Childhood Road Safety
Education Program
00000 IEC Technical Services
00000 IEC Art Room
1 University Avenue
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
Level 4 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
Level 5 00000 Lecture Theatre
00000 Mia Mia Child and Family Study Centre
00000 Centre for Open Education
Teaching Rooms
10
DIRECTORY LAYOUT (8 LEVELS)
31515
6
60
170
170
170
170
170
170
2424
2012
1212
3
350350
34
60 60
55 55
2665
4526
26
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
022 Part Seven Signage Design - Internal
SMALL DIRECTORY - WALL MOUNTED
Sheet 3 of 3I006
GRAPHIC DETAILS
Scale 1:10
SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES
GRAPHIC DETAILS
BUILDING STREET ADDRESS Typeface: National Bold
DIRECTORY TEXT Typeface: National Regular Colour: MQ Charcoal
LEVEL INDICATOR LINE Line height: 3mm Colour: MQ Red
TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
FRONT ELEVATION SCALE 1:10
Ground00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
1 University AvenueGround00000 Museum of Ancient Cultures
00000 Australian Centre for Ancient
Numismatic Studies
00000 IEC Head of Department
Level 1 00000 Early Childhood Road Safety
Education Program
00000 IEC Music Room
Media Teaching Rooms
Level 2 00000 IEC Drama and Movement Room
00000 Early Childhood Road Safety
Education Program
Teaching Rooms
1 University Avenue Level 1Help Point
For help call 0000 0000For help and information
1 University Avenue
350350
Level 3 00000 IEC Drama and Movement Room
00000 Resource Development
Teaching Rooms
10
DIRECTORY LAYOUT (4 LEVELS)
31515
6
60
170
170
170
170
2424
2012
123
34
60 60
55
2665
45
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 023
I009LEVEL ARRIVAL DIRECTIONAL - WALL MOUNTED
Sheet 1 of 4
ELEVATIONS
Scale 1:15
SIGN TYPES IN DETAIL INTERNAL SIGNS –
DIRECTIONAL SERIES
FRONT ELEVATION SCALE 1:15
1060
100
0
160
0
430 30
00000-00000Lecture Theatre 1
≤Rooms 000-000
Lecture Theatre 1
Toilets
<Rooms 000-000
Lecture Theatre 2
Unisex and accessible toilets
>Rooms 000-000
Lecture Theatre 2
LiftandStairs
00000-00000Lecture Theatre 2
00000-00000Lecture Theatre 3
Unisex Toilets
Unisex Toilets
12 Victorian Ash timber detail.Concealed fixtures.
Aluminium two-packpolyurethane facade.
Building number laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.
FRONT SIDE
Braille and tactile messaging. Messages should be restricted to be between 1200-1600mm above the relative floor plan where possible to accommodate for best practice accessible height. Messages however may be extended down to 1000mm above the relative floor plane in the event this is not possible.
Sign use: To direct users around the level they are on
Location: On wall in level arrival area
Typical content: – Level number– Key rooms such as lecture theatres/teaching spaces/
meeting rooms/Deans office/faculty executive– General room number directional– Amenities– Braille and tactile type
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
024 Part Seven Signage Design - Internal
FRONT ELEVATION SCALE 1:10
00000-00000Lecture Theatre 1
≤Rooms 000-000
Lecture Theatre 1
Toilets
<Rooms 000-000
Lecture Theatre 2
Unisex and accessible toilets
>Rooms 000-000
Lecture Theatre 2
LiftandStairs
00000-00000Lecture Theatre 2
00000-00000Lecture Theatre 3
Unisex Toilets
Unisex Toilets
12
6015
660
0
43 43
30 30
3618
4790
9036
478
15
PRIMARY PANEL
LEVEL ARRIVAL DIRECTIONAL - WALL MOUNTED
Sheet 2 of 4I009
GRAPHIC DETAILS
Scale 1:10
SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES
GRAPHIC DETAILS
LEVEL NUMBER Typeface: National Bold
DIRECTORY ARROWS Box height: 18mm Colour: MQ Charcoal
DIRECTORY TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal
PICTOGRAMS Height: 30mm Colour: MQ Charcoal and B21 Ultramarine
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 025
FRONT ELEVATION SCALE 1:10
PRIMARY PANEL SECONDARY PANELA second panel can be added to hold more information if required.
00000-00000Lecture Theatre 1
Unisex Toilets
Unisex Toilets
≤Rooms 000-000
Lecture Theatre 1
Toilets
<Rooms 000-000
Lecture Theatre 2
Unisex and accessible toilets
Rooms 000-000
Lecture Theatre 2
LiftandStairs
00000-00000Lecture Theatre 2
00000-00000Teaching Rooms
00000-00000Teaching Rooms
≤Rooms 000-000
Lecture Theatre 1
Toilets
>Rooms 000-000
Lecture Theatre 2
LiftandStairs
00000-00000Lecture Theatre 3
≤
1260
6015
660
0
38 38
30 30
38 38
30 30
3618
4790
3647
8
15
I009LEVEL ARRIVAL DIRECTIONAL - WALL MOUNTED
Sheet 3 of 4
GRAPHIC DETAILS
Scale 1:10
SIGN TYPES IN DETAIL INTERNAL SIGNS –
DIRECTIONAL SERIES
GRAPHIC DETAILS
LEVEL NUMBER Typeface: National Bold
DIRECTORY ARROWS Box height: 18mm Colour: MQ Charcoal
DIRECTORY TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal
PICTOGRAMS Height: 30mm Colour: MQ Charcoal and B21 Ultramarine
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
026 Part Seven Signage Design - Internal
FRONT ELEVATION SCALE 1:10
EXAMPLES OF LEVEL AND BUILDING NUMBERS
1 2
3 12
22 B5
6015
6
38
41
6015
6
3841
6015
6
38
41
6015
6
38
41
6015
6
38
41
6015
6
35
38
41
LEVEL ARRIVAL DIRECTIONAL - WALL MOUNTED
Sheet 4 of 4I009
GRAPHIC DETAILS
Scale 1:10
SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES
GRAPHIC DETAILS
LEVEL NUMBER Typeface: National Bold
PANEL BACKGROUND Colour: MQ White
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 027
I010LEVEL ARRIVAL DIRECTIONAL - SUSPENDED
Sheet 1 of 2
ELEVATIONS
Scale 1:20
SIGN TYPES IN DETAIL INTERNAL SIGNS –
DIRECTIONAL SERIES
FRONT ELEVATION SCALE 1:20
00000-00000Lecture Theatre 1
00000-00000
00000-00000Lecture Theatre 2
12Lecture Theatre 3
Victorian Ash timber detail. Concealed fixtures.
Aluminium two-packpolyurethane facade.Vinyl messaging applied.
Building level laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.
420
700 30
220
0
FRONT SIDE
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
028 Part Seven Signage Design - Internal
LEVEL ARRIVAL DIRECTIONAL - SUSPENDED
Sheet 2 of 2I010
GRAPHIC DETAILS
Scale 1:10
SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES
GRAPHIC DETAILS
LEVEL NUMBER Typeface: National Bold
BUILDING STREET ADDRESSNational Regular
DIRECTORY ARROWS Box height: 18mm Colour: MQ Charcoal
DIRECTORY TEXT Typeface: National Regular Colour: MQ Charcoal
PICTOGRAMS Height: 30mm Colour: MQ Charcoal and B21 Ultramarine
PANEL BACKGROUND Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
FRONT ELEVATION SCALE 1:10
00000-00000Lecture Theatre 1
00000-00000
00000-00000Lecture Theatre 2
12
6015
6
38 300
Lecture Theatre 3
30 38
3636
3847
5136
4751
30 15
You are now entering
3 Wally’s WalkLevel 4
59
38
3846
3834
4816
4
38
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 029
SIGN TYPES IN DETAIL INTERNAL SIGNS –
DIRECTIONAL SERIES
FRONT ELEVATION
Scale 1:20
LEVEL ARRIVAL DIRECTIONAL - DIRECT FIXED
Sheet 1 of 21010a
FRONT ELEVATION SCALE 1:20
300
Lecture Theatre 1
Rooms 000-000Lecture Theatre 2
12
500
Victorian Ash timber detail. Concealed fixtures.
Aluminium two-packpolyurethane facade.Vinyl messaging applied.
Building level laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.
30
240
0
FRONT SIDE
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
030 Part Seven Signage Design - Internal
GRAPHIC DETAIL
Scale 1: 10
SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES
LEVEL ARRIVAL DIRECTIONAL - DIRECT FIXED
Sheet 2 of 21010a
FRONT ELEVATION SCALE 1:10
You are now entering
3 Wally’s WalkLevel 4
29
42
1829
2924
3311
7
00000-00000Lecture Theatre 1
00000-00000Lecture Theatre 2
12
18
31
2985
1718
2932
1830
35
15
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 031
FRONT ELEVATION SCALE 1:15
00000-00000Lecture Theatre 1
Toilets
12≤Rooms 000-000
Lecture Theatre 1
Toilets
500
1213
160
0
300 30
Victorian Ash timber detail.Concealed fixtures.
Aluminium two-packpolyurethane facade.
Building level laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.
Braille (white) and tactile (charcoal).
FRONT SIDE
I011LEVEL ARRIVAL DIRECTIONAL SMALL - WALL MOUNTED
Sheet 1 of 2
ELEVATIONS
Scale 1:15
SIGN TYPES IN DETAIL INTERNAL SIGNS –
DIRECTIONAL SERIES
Sign use: To direct users around the level they are on
Location: On wall in level arrival area
Typical content: – Level number– Key rooms such as lecture theatres/teaching spaces/
meeting rooms/Deans office/faculty executive– General room number directional– Amenities– Braille and tactile type
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
032 Part Seven Signage Design - Internal
FRONT ELEVATION SCALE 1:5
00000-00000Lecture Theatre 1
Toilets
1236
47
4312
118
30
8625 25
30
≤Rooms 000-000
Lecture Theatre 1
Toilets
LEVEL ARRIVAL DIRECTIONAL SMALL - WALL MOUNTED
Sheet 2 of 2I011
GRAPHIC DETAILS
Scale 1:5
SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES
GRAPHIC DETAILS
LEVEL NUMBER Typeface: National Bold
DIRECTORY ARROWS Box height: 18mm Colour: MQ Charcoal
DIRECTORY TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal
PICTOGRAMS Height: 30mm Colours: MQ Charcoal and B21 Ultramarine
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
Part Seven Signage Design - Internal 033
SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES
FRONT ELEVATION SCALE 1:15
130
535
0
210
Tactile type set in National Bold typeface - BlackBraille - White
Aluminium two-packpolyurethane facade.Vinyl messaging applied.
PRIMARY PANEL (4 LEVELS)
Level 300000-0000 Museum of Ancient Cultures00000-0000 Australian Centre for Ancient Numismatic Studies00000-0000 IEC Administration00000-0000 IEC Student Enquiry Office00000-0000 IEC Head of Department00000-0000 Head of Division
Level 2 00000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms
Level 1 00000 IEC Drama and Movement Room00000 Early Childhood Road Safety Education Program00000 Resource DevelopmentTeaching Rooms
Ground 00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms
1 University Avenue
I013LIFT INTERNAL DIRECTORY
Sheet 1 of 4
FRONT ELEVATION
Scale 1:15
Sign use: To identify the levels within the building
Location: On wall inside lift
Typical content: – Tactile building street address and braille– Faculties /Departments / Research Centres
(National/MU/Faculty)– Key rooms such as lecture theatres/teaching spaces/
meeting rooms/Deans office/faculty executive– Braille and tactile type
SIGN TYPES IN DETAIL INTERNAL SIGNS –
DIRECTIONAL SERIES
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
034 Part Seven Signage Design - Internal
LIFT INTERNAL DIRECTORY
Sheet 2 of 4I013
FRONT ELEVATION
Scale 1:15
FRONT ELEVATION SCALE 1:15
130
535
0
210 210
PRIMARY AND SECONDARY PANEL (8 LEVELS)
Tactile type set in National Bold typeface - BlackBraille - White
Aluminium two-packpolyurethane facade.Vinyl messaging applied.
Level 300000 Museum of Ancient Cultures00000 Australian Centre for Ancient Numismatic Studies00000 IEC Administration00000 IEC Student Enquiry Office00000 IEC Head of Department00000 Head of Division
Level 2 00000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms
Level 1 00000 IEC Drama and Movement Room00000 Early Childhood Road Safety Education Program00000 Resource DevelopmentTeaching Rooms
Ground00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms
Level 700000 Museum of Ancient Cultures00000 IEC Administration00000 IEC Student Enquiry Office00000 IEC Head of Department00000 Head of Division
Level 600000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms
Level 5 00000 IEC Drama and Movement Room00000 Resource DevelopmentTeaching Rooms
Level 4 00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms
1 University Avenue
SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 035
LIFT INTERNAL DIRECTORY
Sheet 3 of 4I013
GRAPHIC DETAILS
Scale 1:4
GRAPHIC DETAILS
BUILDING STREET ADDRESS TACTILE Typeface: National Bold Colour: Black
DIRECTORY TEXT Level typeface: National Regular Room typeface: National Regular Colour: MQ Charcoal
LEVEL INDICATOR LINE Line height: 1mm Colour: MQ Charcoal
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
FRONT ELEVATION SCALE 1:4
Level 300000 Museum of Ancient Cultures00000 Australian Centre for Ancient Numismatic Studies00000 IEC Administration00000 IEC Student Enquiry Office00000 IEC Head of Department00000 Head of Division
Level 2 00000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms
Level 1 00000 IEC Drama and Movement Room00000 Early Childhood Road Safety Education Program00000 Resource DevelopmentTeaching Rooms
Ground 00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms
Level 700000 Museum of Ancient Cultures00000 IEC Administration00000 IEC Student Enquiry Office00000 IEC Head of Department00000 Head of Division
Level 600000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms
Level 5 00000 IEC Drama and Movement Room00000 Resource DevelopmentTeaching Rooms
Level 4 00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms
808
910
6666
17
39
43 4317
39
1518
1721
PRIMARY PANEL SECONDARY PANELA second panel can be added to hold more information if required.
1 University Avenue
SIGN TYPES IN DETAIL INTERNAL SIGNS –
DIRECTIONAL SERIES
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
036 Part Seven Signage Design - Internal
GRAPHIC DETAILS
Scale 1: 4
SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES
I013LIFT INTERNAL DIRECTORY
Sheet 4 of 4
GRAPHIC DETAILS
TACTILE BUILDING STREET ADDRESSTACTILETypeface: National Bold Colour: Black
DIRECTORY TEXT Level typeface: National Regular Room typeface: National Regular Colour: MQ Charcoal
LEVEL INDICATOR LINE Line height: 1mm Colour: MQ Charcoal
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
FRONT ELEVATION SCALE 1:4
1518
17
808
910
6666
17
39
43
21
Level 300000 Museum of Ancient Cultures00000 Australian Centre for Ancient Numismatic Studies00000 IEC Administration00000 IEC Student Enquiry Office00000 IEC Head of Department00000 Head of Division
Level 2 00000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms
Level 1 00000 IEC Drama and Movement Room00000 Early Childhood Road Safety Education Program00000 Resource DevelopmentTeaching Rooms
Ground 00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms
PRIMARY PANEL
1 University Avenue
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 037
I014PLACEMAKING NAMING GRAPHICS
Sheet 1 of 10
FRONT ELEVATION
Scale 1:20
SIGN TYPES IN DETAIL INTERNAL SIGNS –
VENUE/DESTINATION SERIES
FRONT ELEVATION SCALE 1:20
Centre for research on social inclusion
Vinyl messaging appliedColour: MQ Light Grey
2060
200
00000
Mr John MooreFaculty of Business and Economics
100 100
130
5
1213
Sign use: To identify a research centre
Location: Alongside door to centre entrance
Typical content: – Centre name
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
038 Part Seven Signage Design - Internal
PLACEMAKING NAMING GRAPHICS
Sheet 2 of 10I014
GRAPHIC DETAILS
Scale 1:10
SIGN TYPES IN DETAIL INTERNAL SIGNS – VENUE/DESTINATION SERIES
GRAPHIC DETAILS
DESTINATION/VENUE NAME Typeface: National Regular Colour: Mist 745
Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.
FRONT ELEVATION SCALE 1:10
Centre for research on social inclusion
100
100
100
100
100
200
200
200
200
200
200
DESTINATION/VENUE NAMETypeface: National RegularCap X height: 200mm
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 039
I014
GRAPHIC DETAILS
DESTINATION/VENUE NAME Typeface: National Regular Colour: Mist 745
Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.
GRAPHIC DETAILS
Scale 1: 10
TENANT ENTRANCE – INTERNAL
Sheet 3 of 10
FRONT ELEVATION SCALE 1:10
DESTINATION/VENUE NAMETypeface: Replica BoldCap X height: 200mm
Tenant ANameTenant BName
100
150
200
200
200
200
100
SIGN TYPES IN DETAIL INTERNAL SIGNS –
VENUE/DESTINATION SERIES
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
E000
040 Part Seven Signage Design - Internal
SIGN TYPES IN DETAIL INTERNAL SIGNS – VENUE/DESTINATION SERIES
FRONT ELEVATION
Scale 1: 120
SPEECH AND HEARING CLINIC ENTRANCE – INTERNAL
Sheet 4 of 10
FRONT ELEVATION SCALE 1:20
Speech and Hearing Clinic
00000
Mr John MooreFaculty of Business and Economics
Vinyl messaging appliedColour: MQ Light Grey
100 100
2060
130
5
1213
200
GRAPHIC DETAILS
DESTINATION/VENUE NAME Typeface: National Regular Colour: Mist 745
Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.
I014
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 041
I014
GRAPHIC DETAILS
DESTINATION/VENUE NAME Typeface: National Regular Colour: Mist 745
Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.
FRONT ELEVATION
Scale 1: 20
SPEECH AND HEARING CLINIC ENTRANCE – INTERNAL
Sheet 5 of 10
FRONT ELEVATION SCALE 1:20
Speech and Hearing Clinic
Vinyl messaging appliedColour: MQ Light Grey
100 100
130
5
1213
2060
200
00000
Mr John MooreFaculty of Business and Economics
SIGN TYPES IN DETAIL INTERNAL SIGNS –
VENUE/DESTINATION SERIES
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
E000
042 Part Seven Signage Design - Internal
FRONT ELEVATION
Scale 1: 20
HEALTH AND PSYCHOLOGY CLINIC ENTRANCE – INTERNAL
Sheet 6 of 10
FRONT ELEVATION SCALE 1:20
Emotional Health ClinicPsychology Clinic
Vinyl messaging appliedColour: MQ Light Grey
100 100
130
5
1213
2060
200
00000
Mr John MooreFaculty of Business and Economics
GRAPHIC DETAILS
DESTINATION/VENUE NAME Typeface: National Regular Colour: Mist 745
Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.
SIGN TYPES IN DETAIL INTERNAL SIGNS – VENUE/DESTINATION SERIES
I014
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 043
1014
GRAPHIC DETAILS
DESTINATION/VENUE NAME Typeface: National Regular Colour: Mist 745
Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.
AUDIOLOGY ENTRANCE – INTERNAL
Sheet 7 of 10
FRONT ELEVATION
Scale 1: 20FRONT ELEVATION SCALE 1:20
Audiology
Vinyl messaging appliedColour: MQ Light Grey
100 100
130
5
1213
2060
200
00000
Mr John MooreFaculty of Business and Economics
SIGN TYPES IN DETAIL INTERNAL SIGNS –
VENUE/DESTINATION SERIES
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
E000
044 Part Seven Signage Design - Internal
FRONT ELEVATION
Scale 1: 20
SIGN TYPES IN DETAIL INTERNAL SIGNS – VENUE/DESTINATION SERIES
ENTRANCE – INTERNAL
Sheet 8 of 10
FRONT ELEVATION SCALE 1:20
Vinyl messaging appliedColour: MQ Light Grey
100 100
130
5
1213
453
453
2060
00000
Mr John MooreFaculty of Business and Economics
GRAPHIC DETAILS
DESTINATION/VENUE NAME Colour: Mist 745
Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.
I014
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 045
FRONT ELEVATION
Scale 1: 20
GRAPHIC DETAILS
DESTINATION/VENUE NAME Colour: Mist 745
Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.
SIGN TYPES IN DETAIL INTERNAL SIGNS –
VENUE/DESTINATION SERIES
ENTRANCE – INTERNAL
Sheet 9 of 10
FRONT ELEVATION SCALE 1:20
Vinyl messaging appliedColour: MQ Light Grey
100 100
130
5
1213
453
2060
00000
Mr John MooreFaculty of Business and Economics
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
E000
046 Part Seven Signage Design - Internal
FRONT ELEVATION
Scale 1: 20
SIGN TYPES IN DETAIL INTERNAL SIGNS – VENUE/DESTINATION SERIES
PHOTONICS ENTRANCE (INTERNAL)
Sheet 10 of 10
FRONT ELEVATION SCALE 1:20
MQ Photonics – OptoFab and CUDOS
Vinyl messaging appliedColour: MQ Light Grey
100 100
130
5
1213
2060
200
00000
Mr John MooreFaculty of Business and Economics
GRAPHIC DETAILS
DESTINATION/VENUE NAME Typeface: National Regular Colour: Mist 745
Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.
I014
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 047
I016MAJOR INTERNAL DESTINATION/VENUE
Sheet 1 of 2
ELEVATIONS
Scale 1:20
SIGN TYPES IN DETAIL INTERNAL SIGNS –
VENUE/DESTINATION SERIES
FRONT ELEVATION SCALE 1:20
2060
Laser cut aluminium two-packpolyurethane facade.
Victorian Ash timber detail. Concealed pin-fixed.
200
30
FRONT SIDE
Lecture Theatre
G23 Lecture TheatreG23 Lecture Theatre
G23
15" screen
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.
Sign use: Identify a destination/venue
Location: On wall near entrance to venue
Typical content: – Destination/venue name– Direction to venue entrance optional
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
048 Part Seven Signage Design - Internal
MAJOR INTERNAL DESTINATION/VENUE
Sheet 2 of 2I016
GRAPHIC DETAILS
Scale 1:10
SIGN TYPES IN DETAIL INTERNAL SIGNS – VENUE/DESTINATION SERIES
GRAPHIC DETAILS
DESTINATION/VENUE NAME Typeface: National Bold Colour: MQ White
Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.
FRONT ELEVATION SCALE 1:10
200
82
I016
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 049
I018PHONE DIRECTORY
Sheet 1 of 2
ELEVATIONS
Scale 1:15
SIGN TYPES IN DETAIL INTERNAL SIGNS –
INFORMATION SERIES
Sign use: Call individuals/offices
Location: In the foyer of a building or reception area of a department or centre
Typical content: – International telephone icon/building code – Telephone numbers of individuals/offices etc– Room/level number of individuals
FRONT ELEVATION SCALE 1:15
A3
805
100
0
1250
220
0
430 30
Fame edged clear acrylic sliding panel. Printed A3 directory insert.
Phone mounted on a 15-20° angle.
Victorian Ash timber detail. Concealed fixtures.
20°
Pictogram and building number laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.
FRONT SIDE
Flag signage may be used to improve the visability of the phone facility. See I032 for details.
050 Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – INFORMATION SERIES
PHONE DIRECTORY
Sheet 2 of 2I018
GRAPHIC DETAILS
Scale 1:5FRONT ELEVATION SCALE 1:5
A3
3216
8
43
297
276
3232
GRAPHIC DETAILS
PICTOGRAM Height: 168mm
PANEL Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
Part Seven Signage Design - Internal 051
SIGN TYPES IN DETAIL INTERNAL SIGNS –
INFORMATION SERIES
PHONE DIRECTORY - INTERACTIVE
Sheet 1 of 2
ELEVATIONS
Scale 1:15
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
I019
FRONT ELEVATION SCALE 1:15
Flag signage may be used to improve the visability of the phone facility. See I032 for details.
500
300 30
100
0
1250
Pictogram and building number laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.
Victorian Ash timber detail. Concealed fixtures.
Recessed screen with digital name directory. Touch dial pad can call rooms or send an email.Solid aluminium cover to be provided if digital screens not able to be added at time of construction.
Audio outlet
FRONT SIDE
220
0
10" screen
Sign use: Detailed searches for telephone numbers of individuals/offices on interactive screen (iPad). Call individuals directly from search
Location: In the foyer of a building or reception area of a department or centre
Typical content: – International telephone icon/building code– Room/level number of individuals
052 Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – INFORMATION SERIES
PHONE DIRECTORY - INTERACTIVE
Sheet 2 of 2I019
GRAPHIC DETAILS
Scale 1:5
GRAPHIC DETAILS
PICTOGRAM Height: 168mm
PANEL Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
FRONT ELEVATION SCALE 1:5
168
43
3228
40 40
10" screen
Part Seven Signage Design - Internal 053
SIGN TYPES IN DETAIL INTERNAL SIGNS –
SPECIAL ROOMS SERIES
THEATRE ROOM IDENTIFICATION
Sheet 1 of 3
ELEVATIONS
Scale 1:15
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
I020
Sign use: To identify a theatre room. LCD screen to display timetable and information
Location: Alongside the door to the room
Typical content: – Building level – Room number– Theatre name– Tactile building level, room number, theatre name and braille– Timetable or other room information
FRONT ELEVATION SCALE 1:15
805
100
0
1350
Lecture Theatre
G23 Lecture TheatreG23 Lecture Theatre
G23
15" screen
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.
30100 430
Vinyl messaging applied.
Braille and tactile.
Building/room number laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.
Fame edged clear acrylic sliding panel. Printed paper timetable insert.
Victorian Ash timber detail. Concealed fixtures.
FRONT SIDE
054 Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – SPECIAL ROOMS SERIES
THEATRE ROOM IDENTIFICATION
Sheet 2 of 3I020
GRAPHIC DETAILS
Scale 1:5
GRAPHIC DETAILS
BUILDING LEVEL Typeface: National Bold
ROOM NUMBER Typeface: National Bold
ROOM NAME Typeface: National Regular Colour: MQ Charcoal
DISCLAIMER TEXT Typeface: National Regular Colour: MQ Charcoal
TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.
FRONT ELEVATION SCALE 1:5
Lecture Theatre
G23 Lecture TheatreG23 Lecture Theatre
G2328
118
350
43 43
6060
15" screen
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.
Part Seven Signage Design - Internal 055
GRAPHIC DETAILS
Scale 1:5
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS –
SPECIAL ROOMS SERIES
FRONT ELEVATION SCALE 1:5
G23 Lecture TheatreG23 Lecture Theatre
B2300Lecture Theatre 28
7935
0
43 43
6060
15" screen
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.
THEATRE ROOM IDENTIFICATION
Sheet 3 of 3I020
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
056 Part Seven Signage Design - Internal
SIGN TYPES IN DETAIL INTERNAL SIGNS – SPECIAL ROOMS SERIES
I021SPECIAL ROOM IDENTIFICATION
Sheet 1 of 3
ELEVATIONS
Scale 1:15
Sign use: To identify a theatre room. Display of static timetable and information
Location: Alongside the door to the room
Typical content: – Building level – Room number– Theatre name– Timetable or other room information
FRONT ELEVATION SCALE 1:15
805
100
0
1445
G23 Lecture TheatreG23 Lecture Theatre
G23Lecture Theatre
15" screen
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may occur in this
room. Discussions conducted in the room may
be captured.
30100 430
Vinyl messaging applied.
Braille and tactile.
Building level and room number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.
Fame edged clear acrylic sliding panel. Printed paper timetable insert.
Victorian Ash timber detail. Concealed fixtures.
FRONT SIDE
Part Seven Signage Design - Internal 057
SIGN TYPES IN DETAIL INTERNAL SIGNS –
SPECIAL ROOMS SERIES
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
I021SPECIAL ROOM IDENTIFICATION
Sheet 2 of 3
GRAPHIC DETAILS
Scale 1:5
GRAPHIC DETAILS
BUILDING LEVEL Typeface: National Bold
ROOM NUMBER Typeface: National Bold
ROOM NAME Typeface: National Regular Colour: MQ Charcoal
DISCLAIMER TEXT Typeface: National Regular Colour: MQ Charcoal
TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.
FRONT ELEVATION SCALE 1:5
2811
844
4
43 43
6060
G23Lecture Theatre
G23 Lecture TheatreG23 Lecture Theatre
15" screen
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may occur in this
room. Discussions conducted in the room may
be captured.
058 Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – SPECIAL ROOMS SERIES
I021SPECIAL ROOM IDENTIFICATION
Sheet 3 of 3
GRAPHIC DETAILS
Scale 1:5
GRAPHIC DETAILS
BUILDING LEVEL Typeface: National Bold
ROOM NUMBER Typeface: National Bold
ROOM NAME Typeface: National Regular Colour: MQ Charcoal
DISCLAIMER TEXT Typeface: National Regular Colour: MQ Charcoal
TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.
FRONT ELEVATION SCALE 1:5
2879
458
43 43
6077
G23 Lecture TheatreG23 Lecture Theatre
B2300Lecture Theatre
15" screen
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may occur in this
room. Discussions conducted in the room may
be captured.
060 Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – SPECIAL ROOMS SERIES
ELEVATIONS
Scale 1:15
THEATRE ROOM IDENTIFICATION
Sheet 1 of 21022
G23 Lecture TheatreG23 Lecture Theatre
Lecture Theatre
G23
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may ocur
in this room. discussions conducted in
the room may be captured.
FRONT ELEVATION SCALE 1:15
10015
00
1213
Building level and room number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.
Victorian Ash timber detail. Concealed fixtures.
Vinyl messaging applied.Braille and tactile.
FRONT SIDE
500
300 30
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 061
SIGN TYPES IN DETAIL INTERNAL SIGNS –
SPECIAL ROOMS SERIES
I022THEATRE ROOM IDENTIFICATION
Sheet 2 of 2
GRAPHIC DETAILS
Scale 1:5
G23 Lecture TheatreG23 Lecture Theatre
Lecture Theatre
G23
Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may ocur
in this room. discussions conducted in
the room may be captured.
FRONT ELEVATION SCALE 1:5
6028
1623
35 35
152
GRAPHIC DETAILS
BUILDING LEVEL Typeface: National Bold
ROOM NUMBER Typeface: National Bold
ROOM NAME Typeface: National Regular Colour: MQ Charcoal
DISCLAIMER TEXT Typeface: National Regular Colour: MQ Charcoal
TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal
PANEL BACKGROUND Colour: MQ White
BRAILLE Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
062 Part Seven Signage Design - Internal
SIGN TYPES IN DETAIL INTERNAL SIGNS – SPECIAL ROOMS SERIES
SPECIAL ROOM IDENTIFICATION – FLAG
Sheet 1 of 4
ELEVATIONS
Scale 1:20
I024
Sign use: To identify a special room
Location: Above the door to the room
Typical content: – Building level– Room number– Room type/name
FRONT ELEVATION SCALE 1:20
Building level and room number laser cut into aluminium two-pack polyurethane facade
to reveal Victorian Ash timber.
Victorian Ash timber detail.Concealed fixtures. Vinyl messaging
applied.
FRONTSIDE
220
016
0
100
30 267
G23Teaching Room
Part Seven Signage Design - Internal 063
SIGN TYPES IN DETAIL INTERNAL SIGNS –
SPECIAL ROOMS SERIES
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SPECIAL ROOM IDENTIFICATION – FLAG
Sheet 2 of 4I024
ELEVATIONS
Scale 1:10
FRONT ELEVATION SCALE 1:10
SIDE
RIGHT ALIGNED FRONT
LEFT ALIGNED FRONT
G23Teaching RoomTeaching Room
G23
064 Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – SPECIAL ROOMS SERIES
SPECIAL ROOM IDENTIFICATION – FLAG
Sheet 3 of 4
GRAPHIC DETAILS
Scale 1:5
I024
GRAPHIC DETAILS
BUILDING LEVEL Typeface: National Bold
ROOM NUMBER Typeface: National Bold
ROOM NAME Typeface: National Regular Colour: MQ White
PANEL BACKGROUND Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
FRONT ELEVATION SCALE 1:5
1518
14
20 20
1518
14
20 20
G23Teaching Room
Teaching Room
66
G23 66
Part Seven Signage Design - Internal 065
SIGN TYPES IN DETAIL INTERNAL SIGNS –
SPECIAL ROOMS SERIES
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
GRAPHIC DETAILS
Scale 1: 5
SPECIAL ROOM IDENTIFICATION – FLAG
Sheet 4 of 4I024
FRONT ELEVATION SCALE 1:5
15
14
20 20
52
18
46
G8742Teaching Room
15
14
20 20
52
18
B2300Teaching Room
066 Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – AMENITY SERIES
AMENITY IDENTIFICATION
Sheet 1 of 6I026
FRONT ELEVATION SCALE 1:20
100
130
5
First and preferred location on wallnext to door, on same side asdoor handle
Third preferred location(only if first and second
locations are not possible)centred on door
Second preferred location(only if first location is not
possible) on wall next todoor on hinge side
Male ToiletMale Toilet
100
ELEVATIONS
Scale 1:20
Part Seven Signage Design - Internal 067
SIGN TYPES IN DETAIL INTERNAL SIGNS –
AMENITY SERIES
AMENITY IDENTIFICATION
Sheet 2 of 6
ELEVATIONS
Scale 1:20
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
I026
Sign use: To identify an amenity
Location: Alongside the door to the amenity. As per code requirements to achieve 30% contrast between panel and background surface two options have been designed. Select MQ White or MQ Charcoal panel option to suit specific condition.
Typical content: – International symbol (male/female/accessible)– Braille and tactile type
FRONT ELEVATION SCALE 1:20
Male ToiletMale Toilet
Braille (white) and tactile (charcoal).
White matt acrylic. Pictogram MQ Charcoal / Black - Preference is Charcoal. Raised from surface by 1mm.
FRONT SIDE
White matt acrylic
267
100 160 27
130
5
068 Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – AMENITY SERIES
AMENITY IDENTIFICATION
Sheet 3 of 6I026
ELEVATIONS
Scale 1:20
FRONT ELEVATION SCALE 1:20
Male ToiletMale Toilet
Braille (charcoal) and tactile (White).
Aluminium two-pack polyurethane facade.Graphics MQ White.
FRONT SIDE
Charcoal matt acrylic
267
100 160 27
130
5
Male ToiletMale Toilet
Part Seven Signage Design - Internal 069
SIGN TYPES IN DETAIL INTERNAL SIGNS –
AMENITY SERIES
AMENITY IDENTIFICATION
Sheet 4 of 6
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
I026
FRONT ELEVATION
Scale 1:20
DOOR LOCATED SIGNAGE
For ambulant accessible sanitary facility.
FRONT ELEVATION SCALE 1:20
Female Ambulant ToiletFemale ambulant Toilet
Braille (blue) and tactile (white).
Aluminium two-pack polyurethane facade.Graphics MQ White vinyl raised from surface.
100
130
526
7
160
070 Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – AMENITY SERIES
AMENITY IDENTIFICATION
Sheet 5 of 6I026
FRONT ELEVATION
Scale 1:20
DIRECTIONAL SIGNAGE
Where a sanitary facility does not provide accessible unisex facilities use this directional signage to direct users to appropriate facility.
FRONT ELEVATION SCALE 1:20
Unisex ToiletUnisex Accessible Toilet
Male ToiletMale Toilet
100 40
Part Seven Signage Design - Internal 071
FRONT ELEVATION SCALE 1:5
Male ToiletMale Toilet
Unisex Toilet RH Unisex Accessible Toilet RH
Female Ambulant ToiletFemale ambulant Toilet
Indicates left hand (LH) or right hand (RH) use
144
15
832
27
15
Male ToiletMale Toilet
144
15
832
27
15
1514
415
15
832
27320
15
144
15
832
27
SIGN TYPES IN DETAIL INTERNAL SIGNS –
AMENITY SERIES
AMENITY IDENTIFICATION
Sheet 6 of 6
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
I026
GRAPHIC DETAILS
Scale 1:20
GRAPHIC DETAILS
TACTILE PICTOGRAM Colour: MQ Charcoal / Black - Preference is Charcoal Height: 144mm
TACTILE PICTOGRAM ALTERNATIVE Colour: MQ White Height: 144mm
TACTILE TEXT Typeface: National Regular Standard colour: MQ Charcoal on MQ White background Accessibility colour: MQ White
TACTILE TEXT ALTERNATIVE Typeface: National Regular Standard colour: MQ White on MQ Charcoal background Accessibility colour: MQ White
BRAILLEBraille text to be white on all panels.
TACTILE + BRAILLETo be as required by relevant AS and BCA.
ACCESSIBLE AMENITIES Colour: MQ White on B21 Ultramarine background
BRAILLEBraille text to be white on all panels.
TACTILE + BRAILLETo be as required by relevant AS and BCA.
ACCESSIBLE AMENITIES Colour: MQ White on B21 Ultramarine background
072 Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – AMENITY SERIES
AMENITY IDENTIFICATION – FLAG
Sheet 1 of 8I030
ELEVATIONS
Scale 1:20
Sign use: To identify an amenity
Location: Above the door to the amenity
Typical content: – International symbol (male/female/accessible)
ELEVATIONS SCALE 1:20
220
016
0
100
30 267
Pictogram/amenity name laser cutinto aluminium two-pack
to reveal Victorian Ash timber.
Victorian Ash timber detail.Concealed fixtures.
FRONTSIDE
Part Seven Signage Design - Internal 073
SIGN TYPES IN DETAIL INTERNAL SIGNS –
AMENITY SERIES
AMENITY IDENTIFICATION – FLAG
Sheet 2 of 8
ELEVATIONS
Scale 1:10
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
I030
ELEVATIONS SCALE 1:10
SIDE
RIGHT ALIGNED FRONT
LEFT ALIGNED FRONT
074 Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – AMENITY SERIES
AMENITY IDENTIFICATION – FLAG
Sheet 3 of 8I030
GRAPHIC DETAIL LEFT
Scale 1:5
LEFT ALIGNMENT SCALE 1:5
Kitchen
120
2020
26
120
2020
26
120
2020
20 20
35
2020
26
GRAPHIC DETAILS
PICTOGRAM Height: 120mm
AMENITY NAME Typeface: National Bold
STANDARD PANEL Colour: MQ White
ACCESSIBLE PANEL Colour: MQ White on B21 Ultramarine background
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
Part Seven Signage Design - Internal 075
SIGN TYPES IN DETAIL INTERNAL SIGNS –
AMENITY SERIES
AMENITY IDENTIFICATION – FLAG
Sheet 4 of 8
GRAPHIC DETAIL RIGHT
Scale 1:5
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
I030
GRAPHIC DETAILS
PICTOGRAM Height: 120mm
AMENITY NAME Typeface: National Bold
STANDARD PANEL Colour: MQ White
ACCESSIBLE PANEL Colour: MQ White on B21 Ultramarine background
RIGHT ALIGNMENT SCALE 1:5
Kitchen
120
2020
26
120
2020
26
120
2020
20 20
35
2020
26
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
076 Part Seven Signage Design - Internal
SIGN TYPES IN DETAIL INTERNAL SIGNS – AMENITY SERIES
AMENITY IDENTIFICATION – FLAG (OPTION)
Sheet 5 of 8I030
ELEVATIONS
Scale 1:20
Sign use: To identify an amenity
Location: Above the door to the amenity
Typical content: – International symbol (male/female/accessible)
ELEVATIONS SCALE 1:20
220
016
0
100
30 267
Pictogram/amenity MQ Charcoal / BlackPreference is Charcoal for pictogram and amenity name.
White matt acrylic
FRONTSIDE
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 077
SIGN TYPES IN DETAIL INTERNAL SIGNS –
AMENITY SERIES
AMENITY IDENTIFICATION – FLAG (OPTIONAL)
Sheet 6 of 8
ELEVATIONS
Scale 1:10
I030
ELEVATIONS SCALE 1:10
SIDE
RIGHT ALIGNED FRONT
LEFT ALIGNED FRONT
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
078 Part Seven Signage Design - Internal
SIGN TYPES IN DETAIL INTERNAL SIGNS – AMENITY SERIES
AMENITY IDENTIFICATION – FLAG (OPTIONAL)
Sheet 7 of 8I030
GRAPHIC DETAIL LEFT
Scale 1:5
LEFT ALIGNMENT SCALE 1:5
Kitchen
120
2020
26
120
2020
26
120
2020
20 20
35
2020
26
GRAPHIC DETAILS
PICTOGRAM Height: 120mm Colour: MQ Charcoal / Black - Preference is Charcoal
AMENITY NAME Typeface: National Bold
STANDARD PANEL Colour: MQ White
ACCESSIBLE PANEL Colour: MQ White on B21 Ultramarine background
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 079
SIGN TYPES IN DETAIL INTERNAL SIGNS –
AMENITY SERIES
AMENITY IDENTIFICATION – FLAG
Sheet 8 of 8
GRAPHIC DETAIL RIGHT
Scale 1:5
I030
GRAPHIC DETAILS
PICTOGRAM Height: 120mm Colour: MQ Charcoal / Black - Preference is Charcoal
AMENITY NAME Typeface: National Bold
STANDARD PANEL Colour: MQ White
ACCESSIBLE PANEL Colour: MQ White on B21 Ultramarine background
RIGHT ALIGNMENT SCALE 1:5
Kitchen
120
2020
26
120
2020
26
120
2020
20 20
35
2020
26
080 Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – ROOM SERIES
ROOM NUMBER IDENTIFICATION
Sheet 1 of 4I032
ELEVATIONS
Scale 1:20
Sign use: Identify the room and the individual
Location: Alongside the door
Typical content: – Braille and tactile type room number– Faculty/Department/Office– Individuals name
FRONT ELEVATION SCALE 1:20
00000
Mr John MooreFaculty of Business and Economics
00000
Mr John MooreFaculty of Business and Economics17
5
105 13
1213
3mm white gloss acrylic panel
3mm sliding panel - etching substrate with black backing. Name and description etched to reveal white.
10mm black acrylic backing panel
Tactile type set in National Bold typeface - MQ BlackBraille - White
FRONT SIDE
Part Seven Signage Design - Internal 081
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ROOM SERIES
ROOM NUMBER IDENTIFICATION
Sheet 2 of 4
ELEVATIONS
Scale 1:20
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
I032
FRONT ELEVATION SCALE 1:20
00000
Mr John MooreFaculty of Business and Economics
13
1213
105
3mm white gloss panel.
3mm sliding panel - etching substrate with black backing. Name and description etched to reveal white.
00000
Mr John MooreFaculty of Business and Economics
10mm white acrylic backing panel
Tactile type set in National Bold typeface - MQ Black
Braille - White
FRONT SIDE
082 Part Seven Signage Design - Internal
FRONT ELEVATION SCALE 1:20
00000
Mr John MooreFaculty of Business and Economics
1213
100100
First and preferred location on wallnext to door, on same side asdoor handle
Second preferred location(only if first location is not
possible) on wall next todoor on hinge side
Third preferred location(only if first and second
locations are not possible)centred on door
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – ROOM SERIES
ROOM NUMBER IDENTIFICATION
Sheet 3 of 4I032
FRONT ELEVATION
Scale 1:20
LOCATION
This elevation illustrates the order of preference for sign location
Part Seven Signage Design - Internal 083
GRAPHIC DETAIL
Scale 1:2
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ROOM SERIES
ROOM NUMBER IDENTIFICATION
Sheet 4 of 4
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
I032
GRAPHIC DETAILS
TACTILE ROOM NUMBER Typeface: National Bold Colour: MQ Black
BRAILLE Colour: MQ White
STAFF NAME Typeface: National Regular Colour: White
FACULTY NAME Typeface: National Regular Colour: White
PANEL BACKGROUND Colour: MQ White, MQ Black
FRONT ELEVATION SCALE 1:2
12
8
3 10
65
47
1812
1212
105
5
00000
Mr John MooreFaculty of Business and Economics
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 085
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ROOM SERIES
FRONT ELEVATION
Scale 1: 20
HEARING LOOP IDENTIFICATION
Sheet 1 of 4I035
FRONT ELEVATION SCALE 1:20
Hearingloop
Option 1
White matt acrylic. Pictogram B21 Ultramarine. Raised from surface by 1mm.
Braille and tactile.
1213
Option 1
Sign use: To identify the location and type of hearing loop in operation within a specific room.
The content illustrated below indicates a Audio Induction Loop System.
Location: To be located as per AS guidelines and aligned with the broader University strategy in relation to the operation of the hearing assistance across campus.Typical content: Derived from AS1428 as per the type of hearing assistance system that is in use.
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
086 Part Seven Signage Design - Internal
SIGN TYPES IN DETAIL INTERNAL SIGNS – ROOM SERIES
HEARING LOOP IDENTIFICATION
Sheet 2 of 4I035
FRONT ELEVATION
Scale 1: 20FRONT ELEVATION SCALE 1:20
This theatre is fitted with an Infa Red (IR) assistive induction loop assistive listening system.
To use this system, ask for IR receiver, and use hearing aid T-switch if you have one.
This room is fitted with an audio
frequency induction loop assistive
listening system.
To use this system,
ask for Loop receiver, and/or use
hearing aid T-switch if you
haveasass
Option 2
Braille and tactile.
1213
Option 2
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
Part Seven Signage Design - Internal 087
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ROOM SERIES
GRAPHIC DETAILS
TACTILE TEXT Typeface: National RegularColour: B21 Ultramarine
TACTILE PICTOGRAMHeight: 100mmColour: B21 Ultramarine onMQ white background
BRAILLEColour: MQ White
PANEL BACKGROUND Colour: MQ White
NOTE: The content illustrated indicates a Audio Induction Loop System.
GRAPHIC DETAILS
Scale 1:2
HEARING LOOP IDENTIFICATION
Sheet 3 of 4 I035
FRONT ELEVATION SCALE 1:2
Hearingloop
100
1015
100
3 3
37
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
088 Part Seven Signage Design - Internal
HEARING LOOP IDENTIFICATION
Sheet 4 of 4
SIGN TYPES IN DETAIL INTERNAL SIGNS – ROOM SERIES
I035
GRAPHIC DETAILS
Scale 1: 2
FRONT ELEVATION SCALE 1:2
24 24
This Theatre is fitted with an Infra red (IR) assistive listening system.
To use this system, ask for IR receiver, and use hearing aid T-switch if you have one.This room is fitted with an audio
frequency induction loop assistive
listening system.
To use this system,
ask for Loop receiver, and/or use
hearing aid T-switch if you have
one.
2026
2610
0
GRAPHIC DETAILS
TACTILE PICTOGRAM Height: 100mmColour: B21 Ultramarine onMQ white background
TACTILE TEXT Typeface: National RegularColour: B21 Ultramarine on MQ White
BRAILLEColour: MQ White
PANEL BACKGROUND Colour: MQ White
CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08
Part Seven Signage Design - Internal 089
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ROOM SERIES
LAB ROOM NUMBER WITH HAZARD INFORMATION
Sheet 1 of 2
ELEVATIONS
Scale 1:20
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
I036
FRONT ELEVATION SCALE 1:20
In Case Of Emergency Dial 9999
Femtosecond Direct Write Facility
0 2- 0 0 0
00000Contact:Name Name 0000 000 000
Hazardous substances in this area. Do not enter without approval. hazardous substances in this area. Do
not enter without approval.
300
500
130
5
100
Tactile type set in National Regular - BlackBraille - White
FRONT SIDE
13
white matt acrylic panel
Text and pictograms digitally printed onto substrate.
Sign use: Identify a lab room. Provide hazard and safety information
Location: Alongside the door
Typical content: – Braille and tactile text room number– Faculty/Department/Lab– Hazard/safety information– Emergency contact info
090 Part Seven Signage Design - Internal
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
SIGN TYPES IN DETAIL INTERNAL SIGNS – ROOM SERIES
LAB ROOM NUMBER WITH HAZARD INFORMATION
Sheet 2 of 2I036
GRAPHIC DETAILS
Scale 1:5
GRAPHIC DETAILS
TACTILE ROOM NUMBER Typeface: National Regular Colour: MQ Charcoal / Black
BRAILLE Colour: MQ White
FACULTY NAME Typeface: National Regular Colour: MQ Charcoal / Black
HAZARDS, SAFETY & EMERGENCY CONTACT DETAILS Typeface: National Regular Colour: MQ Charcoal / Black
HAZARD & SAFETY PICTOGRAMS Height: 55mm / 30mm
PANEL BACKGROUND Colour: MQ White
FRONT ELEVATION SCALE 1:5
21 13
4015
915
368
1855
2028
1313
767
6450
60
In Case Of Emergency Dial 9999
Femtosecond Direct Write Facility
0 2- 0 0 0
00000Contact:Name Name 0000 000 000
Hazardous substances in this area. Do not enter without approval. hazardous substances in this area. Do
not enter without approval.
Part Seven Signage Design - Internal 091
SIGN TYPES IN DETAIL INTERNAL SIGNS –
ROOM SERIES
ROOM PIN BOARD
Sheet 1 of 1
ELEVATIONS
Scale 1:20
Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group
I039
Sign use: Provide an area for information to be displayed
Location: Alongside the door and room number
Typical content: – Information relevant to the use of the room
FRONT ELEVATION SCALE 1:20
00000
Mr John MooreFaculty of Business and Economics
1213
100
300
500
50
10
Aluminium two-pack polyurethane frame (MQ White).Concealed fixtures.
Inset EchoPanel (Grey 442).