Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

01. EXECUTIVE SUMMARY

5.1 OVERVIEW

Part Seven Signage Design - Internal A

MACQUARIE UNIVERSITYSIGNAGE AND WAYFINDING GUIDELINES

Part Seven / Issue ThreeSignage Design – Internal

07

HEADING

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

HEADING

B Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 001001

HEADING

.00107 SECTION SEVEN: SIGNAGE DESIGN – INTERNAL

SIGN PLACEMENT 002

ENTRY SERIES 004

DIRECTIONAL SERIES 023

VENUE/DESTINATION SERIES 037

INFORMATION SERIES 049

SPECIAL ROOMS SERIES 053

AMENITY SERIES 066

ROOM SERIES 080

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

CONTENTS

01 INTRODUCTION

02 WAYFINDING PRINCIPLES

03 DESIGN ELEMENTS

04 NAMING STRATEGY – EXTERNAL

05 NAMING STRATEGY – INTERNAL

06 SIGNAGE DESIGN – EXTERNAL

07 SIGNAGE DESIGN – INTERNAL >

08 CONSTRUCTION DETAILS

09 SPECIFICATION

APPENDIX 1 ROLLOUT PLANNING SIGN LOCATION OVERVIEW BULK QUANTITIES

APPENDIX 2 SUSTAINABILITY

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

002 Part Seven Signage Design - Internal

SIGN TYPES IN DETAIL INTERNAL SIGNS

SIGN PLACEMENT

FRONT ELEVATION

Scale 1:25

00000-00000Lecture Theatre 1

Toilets

12≤Rooms 000-000

Lecture Theatre 1

Toilets

00000

Mr John MooreFaculty of Business and Economics

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

1 University Avenue

32" screen

Accessible touch zone

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Ground00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00000 IEC Head of Department

00000-00000Lecture Theatre 1

≤Rooms 000-000

Lecture Theatre 1

Toilets

<Rooms 000-000

Lecture Theatre 2

Unisex and accessible toilets

>Rooms 000-000

Lecture Theatre 2

LiftandStairs

00000-00000Lecture Theatre 2

00000-00000Lecture Theatre 3

Unisex Toilets

Unisex Toilets

12Ground00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00.000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

1 University Avenue

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

10

1000mm1000mm

9.7" screeniPad

2060mm

1805mm

1306mm

1213mm

2060mm

1805mm

1714mm1714mm

1213mm

1305mm

A3

Male ToiletMale Toilet

Level 300000-0000 Museum of Ancient Cultures00000-0000 Australian Centre for Ancient Numismatic Studies00000-0000 IEC Administration00000-0000 IEC Student Enquiry Office00000-0000 IEC Head of Department00000-0000 Head of Division

Level 2 00000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms

Level 1 00000 IEC Drama and Movement Room00000 Early Childhood Road Safety Education Program00000 Resource DevelopmentTeaching Rooms

Ground00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms

1 University Avenue

Lecture Theatre

G23 Lecture TheatreG23 Lecture Theatre

G23

15" screen

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.

G23 Lecture TheatreG23 Lecture Theatre

Lecture Theatre

G23

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may ocur

in this room. discussions conducted in

the room may be captured.

In Case Of Emergency Dial 9999

Femtosecond Direct Write Facility

0 2- 0 0 0

00000Contact:Name Name 0000 000 000

Hazardous substances in this area. Do not enter without approval. hazardous substances in this area. Do

not enter without approval.

Sign types have been placed at specific distances from the floor to ensure consistency across the family, and to create a neat and considered alignment of signs when viewing several in one panoramic. The datum line is a fixed measurement from which all signs are to be located. There are two measurements to be considered when installing the various sign types, the hanging line and the base line.

The diagram below illustrates this placement.

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 003

00000-00000Lecture Theatre 1

Toilets

12≤Rooms 000-000

Lecture Theatre 1

Toilets

00000

Mr John MooreFaculty of Business and Economics

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

1 University Avenue

32" screen

Accessible touch zone

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Ground00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00000 IEC Head of Department

00000-00000Lecture Theatre 1

≤Rooms 000-000

Lecture Theatre 1

Toilets

<Rooms 000-000

Lecture Theatre 2

Unisex and accessible toilets

>Rooms 000-000

Lecture Theatre 2

LiftandStairs

00000-00000Lecture Theatre 2

00000-00000Lecture Theatre 3

Unisex Toilets

Unisex Toilets

12Ground00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00.000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

1 University Avenue

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

10

1000mm1000mm

9.7" screeniPad

2060mm

1805mm

1306mm

1213mm

2060mm

1805mm

1714mm1714mm

1213mm

1305mm

A3

Male ToiletMale Toilet

Level 300000-0000 Museum of Ancient Cultures00000-0000 Australian Centre for Ancient Numismatic Studies00000-0000 IEC Administration00000-0000 IEC Student Enquiry Office00000-0000 IEC Head of Department00000-0000 Head of Division

Level 2 00000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms

Level 1 00000 IEC Drama and Movement Room00000 Early Childhood Road Safety Education Program00000 Resource DevelopmentTeaching Rooms

Ground00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms

1 University Avenue

Lecture Theatre

G23 Lecture TheatreG23 Lecture Theatre

G23

15" screen

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.

G23 Lecture TheatreG23 Lecture Theatre

Lecture Theatre

G23

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may ocur

in this room. discussions conducted in

the room may be captured.

In Case Of Emergency Dial 9999

Femtosecond Direct Write Facility

0 2- 0 0 0

00000Contact:Name Name 0000 000 000

Hazardous substances in this area. Do not enter without approval. hazardous substances in this area. Do

not enter without approval.

SIGN TYPES IN DETAIL INTERNAL SIGNS

SIGN PLACEMENT

00000-00000Lecture Theatre 1

Toilets

12≤Rooms 000-000

Lecture Theatre 1

Toilets

00000

Mr John MooreFaculty of Business and Economics

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

1 University Avenue

32" screen

Accessible touch zone

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Ground00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00000 IEC Head of Department

00000-00000Lecture Theatre 1

≤Rooms 000-000

Lecture Theatre 1

Toilets

<Rooms 000-000

Lecture Theatre 2

Unisex and accessible toilets

>Rooms 000-000

Lecture Theatre 2

LiftandStairs

00000-00000Lecture Theatre 2

00000-00000Lecture Theatre 3

Unisex Toilets

Unisex Toilets

12Ground00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00.000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

1 University Avenue

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

10

1000mm1000mm

9.7" screeniPad

2060mm

1805mm

1306mm

1213mm

2060mm

1805mm

1714mm1714mm

1213mm

1305mm

A3

Male ToiletMale Toilet

Level 300000-0000 Museum of Ancient Cultures00000-0000 Australian Centre for Ancient Numismatic Studies00000-0000 IEC Administration00000-0000 IEC Student Enquiry Office00000-0000 IEC Head of Department00000-0000 Head of Division

Level 2 00000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms

Level 1 00000 IEC Drama and Movement Room00000 Early Childhood Road Safety Education Program00000 Resource DevelopmentTeaching Rooms

Ground00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms

1 University Avenue

Lecture Theatre

G23 Lecture TheatreG23 Lecture Theatre

G23

15" screen

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.

G23 Lecture TheatreG23 Lecture Theatre

Lecture Theatre

G23

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may ocur

in this room. discussions conducted in

the room may be captured.

In Case Of Emergency Dial 9999

Femtosecond Direct Write Facility

0 2- 0 0 0

00000Contact:Name Name 0000 000 000

Hazardous substances in this area. Do not enter without approval. hazardous substances in this area. Do

not enter without approval.

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

004 Part Seven Signage Design - Internal

BUILDING ENTRANCE DOOR

Sheet 1 of 1I001

FRONT ELEVATION

Scale 1:20

SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES

FRONT ELEVATION SCALE 1:20

1Entry

Building/door entrance number.Vinyl applied to surface (white or charcoal).Ensure colour of lettering provides a sufficient amount of contrast (minimum of 30% contrast).

50

300

142

Sign use: To identify building entrance

Location: On door at building entrance

Typical content: – Entry – Door number

GRAPHIC DETAILS

ENTRY Typeface: National Bold Colour: MQ White or MQ Charcoal

Note: Indicative size only. Size to be adjusted to suit specific location.

Ensure sign colour provides required illuminance contrast from wall/glass surface.

Part Seven Signage Design - Internal 005

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ENTRY SERIES

BUILDING ENTRANCE ACCESSIBLE PANEL

Sheet 1 of 2

FRONT ELEVATION

Scale 1:20

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

I001a

FRONT ELEVATION SCALE 1:20

Entry1

Entry 1

W2

Entry 1

Aluminium two-pack polyurethane panel.Braille (white) and tactile (charcoal).

105

1350 1278

175

50 - 300mmDetermine on site

Sign use: To identify building entrance (accessible use)

Location: On wall at building entrance clear of opening doors

Typical content: – Entry – Door number

006 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES

BUILDING ENTRANCE ACCESSIBLE PANEL

Sheet 2 of 2I001a

GRAPHIC DETAILS

Scale 1:2FRONT ELEVATION SCALE 1:2

Entry 1

W2

Entry 1

36

815

GRAPHIC DETAILS

TACTILE TYPE AND DOOR NUMBER Typeface: National Regular Colour: MQ Charcoal

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 007

FRONT ELEVATION SCALE 1:20

140 (NOM)

32" screen

Ground00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Accessible touch zone

1 University Avenue Building Name

Goes Here

525

1260

2060

697

156

1050

LCD 32" recessed screen showing interactive building map. 1250mm maximum height for touch screen controls.Access to wiring needed.Solid aluminium cover to be provided if digital screens not able to be added at time of construction.

Victorian Ash timber detail. Concealed fixtures.

Aluminium two-packpolyurethane facade.Vinyl messaging applied.

Building number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.

FRONT SIDE

Braille (white) and tactile (charcoal).

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

I002MAIN DIRECTORY - WALL MOUNTED

Sheet 1 of 5

ELEVATIONS

Scale 1:20

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ENTRY SERIES

Sign use: To identify the levels within the building and allow detailed searches for individual names/offices etc

Location: Main entrance foyer

Typical content: – Building name/street address – Faculties/departments/research centres

(National/MU/Faculty)– Key rooms/lecture theatres/teaching spaces/meeting

rooms/Deans office/faculty executive– Interactive building/level map– Braille and tactile type (only location and security number)

Note: Sign I002, I003 and I006 provide the same function – primary directory to be located at key arrival points within a building. The form varies to provide options that best suit the specific built environment the sign is located in. Whislt the primary message content is the same the graphic layout varies due to the inclusion of a screen or the position of the Tactile + Braille information. During the implementation phase the layout should be selected depending on the inclusion or otherwise of screens and the extent of message content.

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

008 Part Seven Signage Design - Internal

FRONT ELEVATION SCALE 1:20

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

1260

525

2060

697

140 (NOM)

156

1050

LCD 32" recessed screen showing interactive building map.1250mm maximum height for touch screen controls.Access to wiring needed.Solid aluminium cover to be provided if digital screens not able to be added at time of construction.

Victorian Ash timber detail. Concealed fixtures.

Aluminium two-packpolyurethane facade.Vinyl messaging applied.

DIRECTORY WITH BUILDING NAME

Building number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.

FRONT SIDE

1 University Avenue

32" screen

Accessible touch zone

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Braille (white) and tactile (charcoal).

Ground00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00000 IEC Head of Department

MAIN DIRECTORY - WALL MOUNTED

Sheet 2 of 5I002

ELEVATIONS

Scale 1:20

SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 009

MAIN DIRECTORY - WALL MOUNTED

Sheet 3 of 5I003

ELEVATIONS

Scale 1:20

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ENTRY SERIES

FRONT ELEVATION SCALE 1:20

32" screen

Ground00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

1 University Avenue S2.6

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

Accessible touch zone

1260

392 140 (NOM)

2060

697

1050

156

LCD 32" recessed screen showing interactive building map.1250mm maximum height for touch screen controls.Access to wiring needed.Solid aluminium cover to be provided if digital screens not able to be added at time of construction.

Victorian Ash timber detail. Concealed fixtures.

Aluminium two-packpolyurethane facade.Vinyl messaging applied.

Building number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.

FRONT SIDE

I002

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

010 Part Seven Signage Design - Internal

SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES

I002MAIN DIRECTORY - WALL MOUNTED

Sheet 4 of 5

GRAPHIC DETAILS

Scale 1:10

SANITARY FACILITY PICTOGRAM Height: 20mm Colour: MQ Charcoal and B21 Ultramarine

DIRECTORY TEXT Typeface: National Regular Colour: MQ Charcoal

FRONT ELEVATION SCALE 1:10

1 University Avenue

32" screen

Accessible touch zone

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Ground00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00000 IEC Head of Department

10

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

1250

315

6015

6

170

170

170

170

170

170

2420

123

321321

33

118

3838 55 55

26

DIRECTORY LAYOUT (8 LEVELS)

GRAPHIC DETAILS

BUILDING STREET ADDRESS Typeface: National Bold

TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal

LEVEL INDICATOR LINE Line height: 3mm Colour: MQ Red

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section

Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.

This sign should be integrated with tactile ground surface indicators in accordance with AS1428.41 and Part H2 of the BCA.

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 011

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ENTRY SERIES

MAIN DIRECTORY - WALL MOUNTED

Sheet 5 of 5I002

GRAPHIC DETAILS

Scale 1:10

FRONT ELEVATION SCALE 1:10

32" screen

Ground00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Accessible touch zone

1 University Avenue Building Name

Goes Here

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

1250

321321

118

257

156

138

77

315

170

170

170

170

2424

2012

3

10

33 3838 55

2665

45

170

60

216

DIRECTORY LAYOUT (4 LEVELS) WITH BUILDING NAME

SANITARY FACILITY PICTOGRAM Height: 20mm Colour: MQ Charcoal and B21 Ultramarine

DIRECTORY TEXT Typeface: National Regular Colour: MQ Charcoal

GRAPHIC DETAILS

BUILDING STREET ADDRESS Typeface: National Bold

BUILDING NAME Typeface: National Bold

TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal

LEVEL INDICATOR LINE Line height: 3mm Colour: MQ Red

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.

This sign should be integrated with tactile ground surface indicators in accordance with AS1428.41 and Part H2 of the BCA.

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

012 Part Seven Signage Design - Internal

SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES

MAIN DIRECTORY - FREESTANDING

Sheet 1 of 5I003

ELEVATIONS

Scale 1:20

FRONT ELEVATION SCALE 1:20

32" screen

Level 000000 Museum of Ancient Cultures

00000-00000 Australian Centre for Ancient

00000-00000 Numismatic Studies

00000-00000 IEC Head of Department

Level 1 00000-00000 Early Childhood Road Safety

Education Program

00000-00000 IEC Music Room

Media Teaching Rooms

Level 200000-00000 IEC Drama and Movement Room

00000-00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 4 00000-00000 Lecture Theatre

00000-00000 Mia Mia Child and Family Study Centre

00000-00000 Centre for Open Education

Teaching Rooms

Level 600000-00000 IEC Administration

00000-00000 IEC Student Enquiry Office

00000-00000 IEC Head of Department

00000-00000 Head of Division

Level 700000-00000 Early Childhood Road Safety

Education Program

00000-00000 IEC Technical Services

00000-00000 IEC Art Room

Level 3 00000-00000 IEC Drama and Movement Room

00000-00000 Resource Development

Teaching Rooms

Level 5 00000-00000 Lecture Theatre

00000-00000 Mia Mia Child and Family Study Centre

00000-00000 Centre for Open Education

Teaching Rooms

E4 Level 1Help Point

For help call 0000 0000For help and information

1260

392 140 (NOM)

2060

1350

697

700

156

LCD 32" recessed screen showing interactive building map.1250mm maximum height for touch screen controls.Access to wiring needed.Solid aluminium cover to be provided if digital screens not able to be added at time of construction.

Braille and tactile.

Victorian Ash timber detail. Concealed fixtures.

Aluminium two-packpolyurethane facade.Vinyl messaging applied.

Building number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.

FRONT SIDE

1 University Avenue

Sign use: To identify the levels within the building and allow detailed searches for individual names/offices etc

Location: Main entrance foyer

Typical content: – Building street address/building name – Faculties/departments/research centres

(National/MU/Faculty)– Key rooms/lecture theatres/teaching spaces/meeting

rooms/Deans office/faculty executive– Interactive building/level map– Braille and tactile type

Note: This sign must be integrated with tactile

ground locators as specified in AS1428.4.1 Tactile

Ground Surface Indicators.

Note: Sign I002, I003 and I006 provide the same function – primary directory to be located at key arrival points within a building. The form varies to provide options that best suit the specific built environment the sign is located in. Whislt the primary message content is the same the graphic layout varies due to the inclusion of a screen or the position of the Tactile + Braille information. During the implementation phase the layout should be selected depending on the inclusion or otherwise of screens and the extent of message content.

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 013

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ENTRY SERIES

I003MAIN DIRECTORY - FREESTANDING

Sheet 2 of 5

ELEVATIONS

Scale 1:20FRONT ELEVATION SCALE 1:20

1 University Avenue

32" screen

Accessible touch zone

Level 000000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

E4 Level 1Help Point

For help call 0000 0000For help and information

525

1260

2060

697

140 (NOM)

1350

700

156

Braille and tactile.

LCD 32" recessed screen showing interactive building map.1250mm maximum height for touch screen controls.Access to wiring needed.Solid aluminium cover to be provided if digital screens not able to be added at time of construction.

Victorian Ash timber detail. Concealed fixtures.

Aluminium two-packpolyurethane facade.Vinyl messaging applied.

Building number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.

FRONT SIDE

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

014 Part Seven Signage Design - Internal

SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES

I003MAIN DIRECTORY - FREESTANDING

Sheet 3 of 5

ELEVATIONS

Scale 1:20

FRONT ELEVATION SCALE 1:20

140 (NOM)

Victorian Ash timber detail. Concealed fixtures.

SIDE

32" screen

Level 000000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

E4 Level 1Help Point

For help call 0000 0000For help and information

1260

392

2060

1350

697

700

156

LCD 32" recessed screen showing interactive building map.1250mm maximum height for touch screen controls.Access to wiring needed.Solid aluminium cover to be provided if digital screens not able to be added at time of construction.

Braille and tactile.

Aluminium two-packpolyurethane facade.Vinyl messaging applied.

Building number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.

FRONT

1 UniversityAvenue S2.6

Part Seven Signage Design - Internal 015

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ENTRY SERIES

MAIN DIRECTORY - FREESTANDING

Sheet 4 of 5I003

GRAPHIC DETAILS

Scale 1:10

FRONT ELEVATION SCALE 1:10

32" screen

Accessible touch zone

Level 000000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

E4 Level 1Help Point

For help call 0000 0000For help and information

1250

31515

6

60

170

170

170

170

170

170

2424

2012

1212

3

321

10

321

33

118

3838 55 55

2665

4526

26

DIRECTORY LAYOUT (8 LEVELS)

1 University Avenue

SANITARY FACILITY PICTOGRAM Height: 20mm Colour: MQ Charcoal and B21 Ultramarine

DIRECTORY TEXT Typeface: National Regular Colour: MQ Charcoal

LEVEL INDICATOR LINE Line height: 3mm Colour:MQ Red

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

GRAPHIC DETAILS

BUILDING STREET ADDRESS Typeface: National Bold

TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.

This sign should be integrated with tactile ground surface indicators in accordance with AS1428.41 and Part H2 of the BCA.

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

016 Part Seven Signage Design - Internal

SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES

I003MAIN DIRECTORY - FREESTANDING

Sheet 5 of 5

GRAPHIC DETAILS

Scale 1:10

FRONT ELEVATION SCALE 1:10

32" screen

Level 000000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

E4 Level 1Help Point

For help call 0000 0000For help and information

Accessible touch zone

1250

321321

118

156

315

170

170

170

170

2424

2012

3

10

33 3838 55

2665

45

DIRECTORY LAYOUT (4 LEVELS) WITH BUILDING NAME

1561 University

Avenue

TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal

SANITARY FACILITY PICTOGRAM Height: 20mm Colour: MQ Charcoal and B21 Ultramarine

GRAPHIC DETAILS

BUILDING STREET ADDRESS Typeface: National Bold

BUILDING NAME Typeface: National Bold

DIRECTORY TEXT Typeface: National Regular Colour: MQ Charcoal

LEVEL INDICATOR LINE Line height: 3mm Colour: MQ Red

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.

This sign should be integrated with tactile ground surface indicators in accordance with AS1428.41 and Part H2 of the BCA.

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 017

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ENTRY SERIES

I004POSTER AND BROCHURE STAND

Sheet 1 of 1

ELEVATIONS

Scale 1:20

Sign use: Poster and brochure display

Location: At faculty discretion

Typical content: – N/A

FRONT ELEVATION SCALE 1:20

A3POSTER

A3POSTER

A3POSTER

A3POSTER

301260

2060

160

136

8011

568

Victorian Ash timber detail. Concealed fixtures.

Aluminium two-pack polyurethane facade (MQ White).

Flame edged clear acrylic sliding panels. Printed A3 poster insert.

FRONT SIDE

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

018 Part Seven Signage Design - Internal

HELP POINT

Sheet 1 of 2I005

ELEVATIONS

Scale 1:15

SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES

Sign use: To help and provide assistance

Location: At main entrance or a location determined by campus security

Typical content: – Building street address– Help button/intercom– Help/Information telephone number– Braille and tactile type

FRONT ELEVATION SCALE 1:15

Help PointHelp Point

Push button to callPush button to call

Help point

Hearing loopHearing loop

Building number laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.

LED light

Victorian Ash timber detail Concealed fixtures

Aluminium two-packpolyurethane facade

Help point

Aluminium two-packpolyurethane removeable panel

Tactile and Braille

140 (NOM)500

2060

1350

991

500

50

FRONT SIDE

1 University Avenue

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 019

I005HELP POINT

Sheet 2 of 2

GRAPHIC DETAILS

Scale 1:10

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ENTRY SERIES

GRAPHIC DETAILS

BUILDING STREET ADDRESS Typeface: National Bold

HELP POINT Typeface: National Regular Colour: MQ White

INFORMATION PICTOGRAM Height: 49mm Colour: MQ White

TACTILE TEXT Typeface: National Regular Colour: MQ White

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

HELP POINT PANEL BACKGROUND Colour: B21 Ultramarine

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

FRONT ELEVATION SCALE 1:10

Help PointHelp Point

Push button to callPush button to call

Help point

Hearing loopHearing loop

117

8050

6060

60

50 50

1 University Avenue

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

020 Part Seven Signage Design - Internal

SMALL DIRECTORY - WALL MOUNTED

Sheet 1 of 3I006

ELEVATIONS

Scale 1:15

SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES

Sign use: To identify the levels within the building

Location: At main entrance of small building

Typical content: – Building street address– Faculties/departments /research centres

(National/MU/Faculty)– Key rooms lecture theatres/teaching spaces/meeting

rooms– Deans office/faculty executive– Braille and tactile type

FRONT ELEVATION SCALE 1:15

Ground00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00.000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

1 University Avenue

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

10

Building number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.

Victorian Ash timber detail. Concealed fixtures.

Aluminium two-packpolyurethane facade.Vinyl messaging applied.

30854

1425

635

FRONT SIDE

1170

Braille (white) and tactile (charcoal).

Note: Sign I002, I003 and I006 provide the same function – primary directory to be located at key arrival points within a building. The form varies to provide options that best suit the specific built environment the sign is located in. Whislt the primary message content is the same the graphic layout varies due to the inclusion of a screen or the position of the Tactile + Braille information. During the implementation phase the layout should be selected depending on the inclusion or otherwise of screens and the extent of message content.

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 021

I006SMALL DIRECTORY - WALL MOUNTED

Sheet 2 of 3

GRAPHIC DETAILS

Scale 1:10

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ENTRY SERIES

GRAPHIC DETAILS

BUILDING STREET ADDRESS Typeface: National Bold

DIRECTORY TEXT Typeface: National Regular Colour: MQ Charcoal

LEVEL INDICATOR LINE Line height: 3mm Colour: MQ Red

TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

FRONT ELEVATION SCALE 1:10

Ground00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00.000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

1 University AvenueGround00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00.000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

Level 600000 IEC Administration

00000 IEC Student Enquiry Office

00000 IEC Head of Department

00000 Head of Division

Level 700000 Early Childhood Road Safety

Education Program

00000 IEC Technical Services

00000 IEC Art Room

1 University Avenue

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

Level 4 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

Level 5 00000 Lecture Theatre

00000 Mia Mia Child and Family Study Centre

00000 Centre for Open Education

Teaching Rooms

10

DIRECTORY LAYOUT (8 LEVELS)

31515

6

60

170

170

170

170

170

170

2424

2012

1212

3

350350

34

60 60

55 55

2665

4526

26

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

022 Part Seven Signage Design - Internal

SMALL DIRECTORY - WALL MOUNTED

Sheet 3 of 3I006

GRAPHIC DETAILS

Scale 1:10

SIGN TYPES IN DETAIL INTERNAL SIGNS – ENTRY SERIES

GRAPHIC DETAILS

BUILDING STREET ADDRESS Typeface: National Bold

DIRECTORY TEXT Typeface: National Regular Colour: MQ Charcoal

LEVEL INDICATOR LINE Line height: 3mm Colour: MQ Red

TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

FRONT ELEVATION SCALE 1:10

Ground00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

1 University AvenueGround00000 Museum of Ancient Cultures

00000 Australian Centre for Ancient

Numismatic Studies

00000 IEC Head of Department

Level 1 00000 Early Childhood Road Safety

Education Program

00000 IEC Music Room

Media Teaching Rooms

Level 2 00000 IEC Drama and Movement Room

00000 Early Childhood Road Safety

Education Program

Teaching Rooms

1 University Avenue Level 1Help Point

For help call 0000 0000For help and information

1 University Avenue

350350

Level 3 00000 IEC Drama and Movement Room

00000 Resource Development

Teaching Rooms

10

DIRECTORY LAYOUT (4 LEVELS)

31515

6

60

170

170

170

170

2424

2012

123

34

60 60

55

2665

45

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 023

I009LEVEL ARRIVAL DIRECTIONAL - WALL MOUNTED

Sheet 1 of 4

ELEVATIONS

Scale 1:15

SIGN TYPES IN DETAIL INTERNAL SIGNS –

DIRECTIONAL SERIES

FRONT ELEVATION SCALE 1:15

1060

100

0

160

0

430 30

00000-00000Lecture Theatre 1

≤Rooms 000-000

Lecture Theatre 1

Toilets

<Rooms 000-000

Lecture Theatre 2

Unisex and accessible toilets

>Rooms 000-000

Lecture Theatre 2

LiftandStairs

00000-00000Lecture Theatre 2

00000-00000Lecture Theatre 3

Unisex Toilets

Unisex Toilets

12 Victorian Ash timber detail.Concealed fixtures.

Aluminium two-packpolyurethane facade.

Building number laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.

FRONT SIDE

Braille and tactile messaging. Messages should be restricted to be between 1200-1600mm above the relative floor plan where possible to accommodate for best practice accessible height. Messages however may be extended down to 1000mm above the relative floor plane in the event this is not possible.

Sign use: To direct users around the level they are on

Location: On wall in level arrival area

Typical content: – Level number– Key rooms such as lecture theatres/teaching spaces/

meeting rooms/Deans office/faculty executive– General room number directional– Amenities– Braille and tactile type

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

024 Part Seven Signage Design - Internal

FRONT ELEVATION SCALE 1:10

00000-00000Lecture Theatre 1

≤Rooms 000-000

Lecture Theatre 1

Toilets

<Rooms 000-000

Lecture Theatre 2

Unisex and accessible toilets

>Rooms 000-000

Lecture Theatre 2

LiftandStairs

00000-00000Lecture Theatre 2

00000-00000Lecture Theatre 3

Unisex Toilets

Unisex Toilets

12

6015

660

0

43 43

30 30

3618

4790

9036

478

15

PRIMARY PANEL

LEVEL ARRIVAL DIRECTIONAL - WALL MOUNTED

Sheet 2 of 4I009

GRAPHIC DETAILS

Scale 1:10

SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES

GRAPHIC DETAILS

LEVEL NUMBER Typeface: National Bold

DIRECTORY ARROWS Box height: 18mm Colour: MQ Charcoal

DIRECTORY TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal

PICTOGRAMS Height: 30mm Colour: MQ Charcoal and B21 Ultramarine

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 025

FRONT ELEVATION SCALE 1:10

PRIMARY PANEL SECONDARY PANELA second panel can be added to hold more information if required.

00000-00000Lecture Theatre 1

Unisex Toilets

Unisex Toilets

≤Rooms 000-000

Lecture Theatre 1

Toilets

<Rooms 000-000

Lecture Theatre 2

Unisex and accessible toilets

Rooms 000-000

Lecture Theatre 2

LiftandStairs

00000-00000Lecture Theatre 2

00000-00000Teaching Rooms

00000-00000Teaching Rooms

≤Rooms 000-000

Lecture Theatre 1

Toilets

>Rooms 000-000

Lecture Theatre 2

LiftandStairs

00000-00000Lecture Theatre 3

1260

6015

660

0

38 38

30 30

38 38

30 30

3618

4790

3647

8

15

I009LEVEL ARRIVAL DIRECTIONAL - WALL MOUNTED

Sheet 3 of 4

GRAPHIC DETAILS

Scale 1:10

SIGN TYPES IN DETAIL INTERNAL SIGNS –

DIRECTIONAL SERIES

GRAPHIC DETAILS

LEVEL NUMBER Typeface: National Bold

DIRECTORY ARROWS Box height: 18mm Colour: MQ Charcoal

DIRECTORY TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal

PICTOGRAMS Height: 30mm Colour: MQ Charcoal and B21 Ultramarine

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

026 Part Seven Signage Design - Internal

FRONT ELEVATION SCALE 1:10

EXAMPLES OF LEVEL AND BUILDING NUMBERS

1 2

3 12

22 B5

6015

6

38

41

6015

6

3841

6015

6

38

41

6015

6

38

41

6015

6

38

41

6015

6

35

38

41

LEVEL ARRIVAL DIRECTIONAL - WALL MOUNTED

Sheet 4 of 4I009

GRAPHIC DETAILS

Scale 1:10

SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES

GRAPHIC DETAILS

LEVEL NUMBER Typeface: National Bold

PANEL BACKGROUND Colour: MQ White

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 027

I010LEVEL ARRIVAL DIRECTIONAL - SUSPENDED

Sheet 1 of 2

ELEVATIONS

Scale 1:20

SIGN TYPES IN DETAIL INTERNAL SIGNS –

DIRECTIONAL SERIES

FRONT ELEVATION SCALE 1:20

00000-00000Lecture Theatre 1

00000-00000

00000-00000Lecture Theatre 2

12Lecture Theatre 3

Victorian Ash timber detail. Concealed fixtures.

Aluminium two-packpolyurethane facade.Vinyl messaging applied.

Building level laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.

420

700 30

220

0

FRONT SIDE

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

028 Part Seven Signage Design - Internal

LEVEL ARRIVAL DIRECTIONAL - SUSPENDED

Sheet 2 of 2I010

GRAPHIC DETAILS

Scale 1:10

SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES

GRAPHIC DETAILS

LEVEL NUMBER Typeface: National Bold

BUILDING STREET ADDRESSNational Regular

DIRECTORY ARROWS Box height: 18mm Colour: MQ Charcoal

DIRECTORY TEXT Typeface: National Regular Colour: MQ Charcoal

PICTOGRAMS Height: 30mm Colour: MQ Charcoal and B21 Ultramarine

PANEL BACKGROUND Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

FRONT ELEVATION SCALE 1:10

00000-00000Lecture Theatre 1

00000-00000

00000-00000Lecture Theatre 2

12

6015

6

38 300

Lecture Theatre 3

30 38

3636

3847

5136

4751

30 15

You are now entering

3 Wally’s WalkLevel 4

59

38

3846

3834

4816

4

38

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 029

SIGN TYPES IN DETAIL INTERNAL SIGNS –

DIRECTIONAL SERIES

FRONT ELEVATION

Scale 1:20

LEVEL ARRIVAL DIRECTIONAL - DIRECT FIXED

Sheet 1 of 21010a

FRONT ELEVATION SCALE 1:20

300

Lecture Theatre 1

Rooms 000-000Lecture Theatre 2

12

500

Victorian Ash timber detail. Concealed fixtures.

Aluminium two-packpolyurethane facade.Vinyl messaging applied.

Building level laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.

30

240

0

FRONT SIDE

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

030 Part Seven Signage Design - Internal

GRAPHIC DETAIL

Scale 1: 10

SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES

LEVEL ARRIVAL DIRECTIONAL - DIRECT FIXED

Sheet 2 of 21010a

FRONT ELEVATION SCALE 1:10

You are now entering

3 Wally’s WalkLevel 4

29

42

1829

2924

3311

7

00000-00000Lecture Theatre 1

00000-00000Lecture Theatre 2

12

18

31

2985

1718

2932

1830

35

15

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 031

FRONT ELEVATION SCALE 1:15

00000-00000Lecture Theatre 1

Toilets

12≤Rooms 000-000

Lecture Theatre 1

Toilets

500

1213

160

0

300 30

Victorian Ash timber detail.Concealed fixtures.

Aluminium two-packpolyurethane facade.

Building level laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.

Braille (white) and tactile (charcoal).

FRONT SIDE

I011LEVEL ARRIVAL DIRECTIONAL SMALL - WALL MOUNTED

Sheet 1 of 2

ELEVATIONS

Scale 1:15

SIGN TYPES IN DETAIL INTERNAL SIGNS –

DIRECTIONAL SERIES

Sign use: To direct users around the level they are on

Location: On wall in level arrival area

Typical content: – Level number– Key rooms such as lecture theatres/teaching spaces/

meeting rooms/Deans office/faculty executive– General room number directional– Amenities– Braille and tactile type

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

032 Part Seven Signage Design - Internal

FRONT ELEVATION SCALE 1:5

00000-00000Lecture Theatre 1

Toilets

1236

47

4312

118

30

8625 25

30

≤Rooms 000-000

Lecture Theatre 1

Toilets

LEVEL ARRIVAL DIRECTIONAL SMALL - WALL MOUNTED

Sheet 2 of 2I011

GRAPHIC DETAILS

Scale 1:5

SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES

GRAPHIC DETAILS

LEVEL NUMBER Typeface: National Bold

DIRECTORY ARROWS Box height: 18mm Colour: MQ Charcoal

DIRECTORY TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal

PICTOGRAMS Height: 30mm Colours: MQ Charcoal and B21 Ultramarine

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

Part Seven Signage Design - Internal 033

SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES

FRONT ELEVATION SCALE 1:15

130

535

0

210

Tactile type set in National Bold typeface - BlackBraille - White

Aluminium two-packpolyurethane facade.Vinyl messaging applied.

PRIMARY PANEL (4 LEVELS)

Level 300000-0000 Museum of Ancient Cultures00000-0000 Australian Centre for Ancient Numismatic Studies00000-0000 IEC Administration00000-0000 IEC Student Enquiry Office00000-0000 IEC Head of Department00000-0000 Head of Division

Level 2 00000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms

Level 1 00000 IEC Drama and Movement Room00000 Early Childhood Road Safety Education Program00000 Resource DevelopmentTeaching Rooms

Ground 00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms

1 University Avenue

I013LIFT INTERNAL DIRECTORY

Sheet 1 of 4

FRONT ELEVATION

Scale 1:15

Sign use: To identify the levels within the building

Location: On wall inside lift

Typical content: – Tactile building street address and braille– Faculties /Departments / Research Centres

(National/MU/Faculty)– Key rooms such as lecture theatres/teaching spaces/

meeting rooms/Deans office/faculty executive– Braille and tactile type

SIGN TYPES IN DETAIL INTERNAL SIGNS –

DIRECTIONAL SERIES

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

034 Part Seven Signage Design - Internal

LIFT INTERNAL DIRECTORY

Sheet 2 of 4I013

FRONT ELEVATION

Scale 1:15

FRONT ELEVATION SCALE 1:15

130

535

0

210 210

PRIMARY AND SECONDARY PANEL (8 LEVELS)

Tactile type set in National Bold typeface - BlackBraille - White

Aluminium two-packpolyurethane facade.Vinyl messaging applied.

Level 300000 Museum of Ancient Cultures00000 Australian Centre for Ancient Numismatic Studies00000 IEC Administration00000 IEC Student Enquiry Office00000 IEC Head of Department00000 Head of Division

Level 2 00000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms

Level 1 00000 IEC Drama and Movement Room00000 Early Childhood Road Safety Education Program00000 Resource DevelopmentTeaching Rooms

Ground00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms

Level 700000 Museum of Ancient Cultures00000 IEC Administration00000 IEC Student Enquiry Office00000 IEC Head of Department00000 Head of Division

Level 600000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms

Level 5 00000 IEC Drama and Movement Room00000 Resource DevelopmentTeaching Rooms

Level 4 00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms

1 University Avenue

SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 035

LIFT INTERNAL DIRECTORY

Sheet 3 of 4I013

GRAPHIC DETAILS

Scale 1:4

GRAPHIC DETAILS

BUILDING STREET ADDRESS TACTILE Typeface: National Bold Colour: Black

DIRECTORY TEXT Level typeface: National Regular Room typeface: National Regular Colour: MQ Charcoal

LEVEL INDICATOR LINE Line height: 1mm Colour: MQ Charcoal

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

FRONT ELEVATION SCALE 1:4

Level 300000 Museum of Ancient Cultures00000 Australian Centre for Ancient Numismatic Studies00000 IEC Administration00000 IEC Student Enquiry Office00000 IEC Head of Department00000 Head of Division

Level 2 00000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms

Level 1 00000 IEC Drama and Movement Room00000 Early Childhood Road Safety Education Program00000 Resource DevelopmentTeaching Rooms

Ground 00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms

Level 700000 Museum of Ancient Cultures00000 IEC Administration00000 IEC Student Enquiry Office00000 IEC Head of Department00000 Head of Division

Level 600000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms

Level 5 00000 IEC Drama and Movement Room00000 Resource DevelopmentTeaching Rooms

Level 4 00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms

808

910

6666

17

39

43 4317

39

1518

1721

PRIMARY PANEL SECONDARY PANELA second panel can be added to hold more information if required.

1 University Avenue

SIGN TYPES IN DETAIL INTERNAL SIGNS –

DIRECTIONAL SERIES

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

036 Part Seven Signage Design - Internal

GRAPHIC DETAILS

Scale 1: 4

SIGN TYPES IN DETAIL INTERNAL SIGNS – DIRECTIONAL SERIES

I013LIFT INTERNAL DIRECTORY

Sheet 4 of 4

GRAPHIC DETAILS

TACTILE BUILDING STREET ADDRESSTACTILETypeface: National Bold Colour: Black

DIRECTORY TEXT Level typeface: National Regular Room typeface: National Regular Colour: MQ Charcoal

LEVEL INDICATOR LINE Line height: 1mm Colour: MQ Charcoal

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

FRONT ELEVATION SCALE 1:4

1518

17

808

910

6666

17

39

43

21

Level 300000 Museum of Ancient Cultures00000 Australian Centre for Ancient Numismatic Studies00000 IEC Administration00000 IEC Student Enquiry Office00000 IEC Head of Department00000 Head of Division

Level 2 00000 Early Childhood Road Safety Education Program00000 IEC Technical Services00000 IEC Art Room00000 IEC Music RoomMedia Teaching Rooms

Level 1 00000 IEC Drama and Movement Room00000 Early Childhood Road Safety Education Program00000 Resource DevelopmentTeaching Rooms

Ground 00000 Lecture Theatre 00000 Mia Mia Child and Family Study Centre00000 Centre for Open EducationTeaching Rooms

PRIMARY PANEL

1 University Avenue

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 037

I014PLACEMAKING NAMING GRAPHICS

Sheet 1 of 10

FRONT ELEVATION

Scale 1:20

SIGN TYPES IN DETAIL INTERNAL SIGNS –

VENUE/DESTINATION SERIES

FRONT ELEVATION SCALE 1:20

Centre for research on social inclusion

Vinyl messaging appliedColour: MQ Light Grey

2060

200

00000

Mr John MooreFaculty of Business and Economics

100 100

130

5

1213

Sign use: To identify a research centre

Location: Alongside door to centre entrance

Typical content: – Centre name

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

038 Part Seven Signage Design - Internal

PLACEMAKING NAMING GRAPHICS

Sheet 2 of 10I014

GRAPHIC DETAILS

Scale 1:10

SIGN TYPES IN DETAIL INTERNAL SIGNS – VENUE/DESTINATION SERIES

GRAPHIC DETAILS

DESTINATION/VENUE NAME Typeface: National Regular Colour: Mist 745

Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.

FRONT ELEVATION SCALE 1:10

Centre for research on social inclusion

100

100

100

100

100

200

200

200

200

200

200

DESTINATION/VENUE NAMETypeface: National RegularCap X height: 200mm

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 039

I014

GRAPHIC DETAILS

DESTINATION/VENUE NAME Typeface: National Regular Colour: Mist 745

Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.

GRAPHIC DETAILS

Scale 1: 10

TENANT ENTRANCE – INTERNAL

Sheet 3 of 10

FRONT ELEVATION SCALE 1:10

DESTINATION/VENUE NAMETypeface: Replica BoldCap X height: 200mm

Tenant ANameTenant BName

100

150

200

200

200

200

100

SIGN TYPES IN DETAIL INTERNAL SIGNS –

VENUE/DESTINATION SERIES

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

E000

040 Part Seven Signage Design - Internal

SIGN TYPES IN DETAIL INTERNAL SIGNS – VENUE/DESTINATION SERIES

FRONT ELEVATION

Scale 1: 120

SPEECH AND HEARING CLINIC ENTRANCE – INTERNAL

Sheet 4 of 10

FRONT ELEVATION SCALE 1:20

Speech and Hearing Clinic

00000

Mr John MooreFaculty of Business and Economics

Vinyl messaging appliedColour: MQ Light Grey

100 100

2060

130

5

1213

200

GRAPHIC DETAILS

DESTINATION/VENUE NAME Typeface: National Regular Colour: Mist 745

Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.

I014

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 041

I014

GRAPHIC DETAILS

DESTINATION/VENUE NAME Typeface: National Regular Colour: Mist 745

Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.

FRONT ELEVATION

Scale 1: 20

SPEECH AND HEARING CLINIC ENTRANCE – INTERNAL

Sheet 5 of 10

FRONT ELEVATION SCALE 1:20

Speech and Hearing Clinic

Vinyl messaging appliedColour: MQ Light Grey

100 100

130

5

1213

2060

200

00000

Mr John MooreFaculty of Business and Economics

SIGN TYPES IN DETAIL INTERNAL SIGNS –

VENUE/DESTINATION SERIES

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

E000

042 Part Seven Signage Design - Internal

FRONT ELEVATION

Scale 1: 20

HEALTH AND PSYCHOLOGY CLINIC ENTRANCE – INTERNAL

Sheet 6 of 10

FRONT ELEVATION SCALE 1:20

Emotional Health ClinicPsychology Clinic

Vinyl messaging appliedColour: MQ Light Grey

100 100

130

5

1213

2060

200

00000

Mr John MooreFaculty of Business and Economics

GRAPHIC DETAILS

DESTINATION/VENUE NAME Typeface: National Regular Colour: Mist 745

Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.

SIGN TYPES IN DETAIL INTERNAL SIGNS – VENUE/DESTINATION SERIES

I014

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 043

1014

GRAPHIC DETAILS

DESTINATION/VENUE NAME Typeface: National Regular Colour: Mist 745

Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.

AUDIOLOGY ENTRANCE – INTERNAL

Sheet 7 of 10

FRONT ELEVATION

Scale 1: 20FRONT ELEVATION SCALE 1:20

Audiology

Vinyl messaging appliedColour: MQ Light Grey

100 100

130

5

1213

2060

200

00000

Mr John MooreFaculty of Business and Economics

SIGN TYPES IN DETAIL INTERNAL SIGNS –

VENUE/DESTINATION SERIES

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

E000

044 Part Seven Signage Design - Internal

FRONT ELEVATION

Scale 1: 20

SIGN TYPES IN DETAIL INTERNAL SIGNS – VENUE/DESTINATION SERIES

ENTRANCE – INTERNAL

Sheet 8 of 10

FRONT ELEVATION SCALE 1:20

Vinyl messaging appliedColour: MQ Light Grey

100 100

130

5

1213

453

453

2060

00000

Mr John MooreFaculty of Business and Economics

GRAPHIC DETAILS

DESTINATION/VENUE NAME Colour: Mist 745

Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.

I014

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 045

FRONT ELEVATION

Scale 1: 20

GRAPHIC DETAILS

DESTINATION/VENUE NAME Colour: Mist 745

Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.

SIGN TYPES IN DETAIL INTERNAL SIGNS –

VENUE/DESTINATION SERIES

ENTRANCE – INTERNAL

Sheet 9 of 10

FRONT ELEVATION SCALE 1:20

Vinyl messaging appliedColour: MQ Light Grey

100 100

130

5

1213

453

2060

00000

Mr John MooreFaculty of Business and Economics

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

E000

046 Part Seven Signage Design - Internal

FRONT ELEVATION

Scale 1: 20

SIGN TYPES IN DETAIL INTERNAL SIGNS – VENUE/DESTINATION SERIES

PHOTONICS ENTRANCE (INTERNAL)

Sheet 10 of 10

FRONT ELEVATION SCALE 1:20

MQ Photonics – OptoFab and CUDOS

Vinyl messaging appliedColour: MQ Light Grey

100 100

130

5

1213

2060

200

00000

Mr John MooreFaculty of Business and Economics

GRAPHIC DETAILS

DESTINATION/VENUE NAME Typeface: National Regular Colour: Mist 745

Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.

I014

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 047

I016MAJOR INTERNAL DESTINATION/VENUE

Sheet 1 of 2

ELEVATIONS

Scale 1:20

SIGN TYPES IN DETAIL INTERNAL SIGNS –

VENUE/DESTINATION SERIES

FRONT ELEVATION SCALE 1:20

2060

Laser cut aluminium two-packpolyurethane facade.

Victorian Ash timber detail. Concealed pin-fixed.

200

30

FRONT SIDE

Lecture Theatre

G23 Lecture TheatreG23 Lecture Theatre

G23

15" screen

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.

Sign use: Identify a destination/venue

Location: On wall near entrance to venue

Typical content: – Destination/venue name– Direction to venue entrance optional

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

048 Part Seven Signage Design - Internal

MAJOR INTERNAL DESTINATION/VENUE

Sheet 2 of 2I016

GRAPHIC DETAILS

Scale 1:10

SIGN TYPES IN DETAIL INTERNAL SIGNS – VENUE/DESTINATION SERIES

GRAPHIC DETAILS

DESTINATION/VENUE NAME Typeface: National Bold Colour: MQ White

Note: Ensure sign colour provides required illuminance contrast from wall/glass surface.

FRONT ELEVATION SCALE 1:10

200

82

I016

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 049

I018PHONE DIRECTORY

Sheet 1 of 2

ELEVATIONS

Scale 1:15

SIGN TYPES IN DETAIL INTERNAL SIGNS –

INFORMATION SERIES

Sign use: Call individuals/offices

Location: In the foyer of a building or reception area of a department or centre

Typical content: – International telephone icon/building code – Telephone numbers of individuals/offices etc– Room/level number of individuals

FRONT ELEVATION SCALE 1:15

A3

805

100

0

1250

220

0

430 30

Fame edged clear acrylic sliding panel. Printed A3 directory insert.

Phone mounted on a 15-20° angle.

Victorian Ash timber detail. Concealed fixtures.

20°

Pictogram and building number laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.

FRONT SIDE

Flag signage may be used to improve the visability of the phone facility. See I032 for details.

050 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – INFORMATION SERIES

PHONE DIRECTORY

Sheet 2 of 2I018

GRAPHIC DETAILS

Scale 1:5FRONT ELEVATION SCALE 1:5

A3

3216

8

43

297

276

3232

GRAPHIC DETAILS

PICTOGRAM Height: 168mm

PANEL Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

Part Seven Signage Design - Internal 051

SIGN TYPES IN DETAIL INTERNAL SIGNS –

INFORMATION SERIES

PHONE DIRECTORY - INTERACTIVE

Sheet 1 of 2

ELEVATIONS

Scale 1:15

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

I019

FRONT ELEVATION SCALE 1:15

Flag signage may be used to improve the visability of the phone facility. See I032 for details.

500

300 30

100

0

1250

Pictogram and building number laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.

Victorian Ash timber detail. Concealed fixtures.

Recessed screen with digital name directory. Touch dial pad can call rooms or send an email.Solid aluminium cover to be provided if digital screens not able to be added at time of construction.

Audio outlet

FRONT SIDE

220

0

10" screen

Sign use: Detailed searches for telephone numbers of individuals/offices on interactive screen (iPad). Call individuals directly from search

Location: In the foyer of a building or reception area of a department or centre

Typical content: – International telephone icon/building code– Room/level number of individuals

052 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – INFORMATION SERIES

PHONE DIRECTORY - INTERACTIVE

Sheet 2 of 2I019

GRAPHIC DETAILS

Scale 1:5

GRAPHIC DETAILS

PICTOGRAM Height: 168mm

PANEL Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

FRONT ELEVATION SCALE 1:5

168

43

3228

40 40

10" screen

Part Seven Signage Design - Internal 053

SIGN TYPES IN DETAIL INTERNAL SIGNS –

SPECIAL ROOMS SERIES

THEATRE ROOM IDENTIFICATION

Sheet 1 of 3

ELEVATIONS

Scale 1:15

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

I020

Sign use: To identify a theatre room. LCD screen to display timetable and information

Location: Alongside the door to the room

Typical content: – Building level – Room number– Theatre name– Tactile building level, room number, theatre name and braille– Timetable or other room information

FRONT ELEVATION SCALE 1:15

805

100

0

1350

Lecture Theatre

G23 Lecture TheatreG23 Lecture Theatre

G23

15" screen

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.

30100 430

Vinyl messaging applied.

Braille and tactile.

Building/room number laser cut into aluminium two-pack polyurethane facadeto reveal Victorian Ash timber.

Fame edged clear acrylic sliding panel. Printed paper timetable insert.

Victorian Ash timber detail. Concealed fixtures.

FRONT SIDE

054 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – SPECIAL ROOMS SERIES

THEATRE ROOM IDENTIFICATION

Sheet 2 of 3I020

GRAPHIC DETAILS

Scale 1:5

GRAPHIC DETAILS

BUILDING LEVEL Typeface: National Bold

ROOM NUMBER Typeface: National Bold

ROOM NAME Typeface: National Regular Colour: MQ Charcoal

DISCLAIMER TEXT Typeface: National Regular Colour: MQ Charcoal

TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.

FRONT ELEVATION SCALE 1:5

Lecture Theatre

G23 Lecture TheatreG23 Lecture Theatre

G2328

118

350

43 43

6060

15" screen

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.

Part Seven Signage Design - Internal 055

GRAPHIC DETAILS

Scale 1:5

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS –

SPECIAL ROOMS SERIES

FRONT ELEVATION SCALE 1:5

G23 Lecture TheatreG23 Lecture Theatre

B2300Lecture Theatre 28

7935

0

43 43

6060

15" screen

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.

THEATRE ROOM IDENTIFICATION

Sheet 3 of 3I020

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

056 Part Seven Signage Design - Internal

SIGN TYPES IN DETAIL INTERNAL SIGNS – SPECIAL ROOMS SERIES

I021SPECIAL ROOM IDENTIFICATION

Sheet 1 of 3

ELEVATIONS

Scale 1:15

Sign use: To identify a theatre room. Display of static timetable and information

Location: Alongside the door to the room

Typical content: – Building level – Room number– Theatre name– Timetable or other room information

FRONT ELEVATION SCALE 1:15

805

100

0

1445

G23 Lecture TheatreG23 Lecture Theatre

G23Lecture Theatre

15" screen

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may occur in this

room. Discussions conducted in the room may

be captured.

30100 430

Vinyl messaging applied.

Braille and tactile.

Building level and room number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.

Fame edged clear acrylic sliding panel. Printed paper timetable insert.

Victorian Ash timber detail. Concealed fixtures.

FRONT SIDE

Part Seven Signage Design - Internal 057

SIGN TYPES IN DETAIL INTERNAL SIGNS –

SPECIAL ROOMS SERIES

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

I021SPECIAL ROOM IDENTIFICATION

Sheet 2 of 3

GRAPHIC DETAILS

Scale 1:5

GRAPHIC DETAILS

BUILDING LEVEL Typeface: National Bold

ROOM NUMBER Typeface: National Bold

ROOM NAME Typeface: National Regular Colour: MQ Charcoal

DISCLAIMER TEXT Typeface: National Regular Colour: MQ Charcoal

TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.

FRONT ELEVATION SCALE 1:5

2811

844

4

43 43

6060

G23Lecture Theatre

G23 Lecture TheatreG23 Lecture Theatre

15" screen

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may occur in this

room. Discussions conducted in the room may

be captured.

058 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – SPECIAL ROOMS SERIES

I021SPECIAL ROOM IDENTIFICATION

Sheet 3 of 3

GRAPHIC DETAILS

Scale 1:5

GRAPHIC DETAILS

BUILDING LEVEL Typeface: National Bold

ROOM NUMBER Typeface: National Bold

ROOM NAME Typeface: National Regular Colour: MQ Charcoal

DISCLAIMER TEXT Typeface: National Regular Colour: MQ Charcoal

TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.

FRONT ELEVATION SCALE 1:5

2879

458

43 43

6077

G23 Lecture TheatreG23 Lecture Theatre

B2300Lecture Theatre

15" screen

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may occur in this

room. Discussions conducted in the room may

be captured.

Part Seven Signage Design - Internal 059

060 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – SPECIAL ROOMS SERIES

ELEVATIONS

Scale 1:15

THEATRE ROOM IDENTIFICATION

Sheet 1 of 21022

G23 Lecture TheatreG23 Lecture Theatre

Lecture Theatre

G23

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may ocur

in this room. discussions conducted in

the room may be captured.

FRONT ELEVATION SCALE 1:15

10015

00

1213

Building level and room number laser cut into aluminium two-pack polyurethane facade to reveal Victorian Ash timber.

Victorian Ash timber detail. Concealed fixtures.

Vinyl messaging applied.Braille and tactile.

FRONT SIDE

500

300 30

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 061

SIGN TYPES IN DETAIL INTERNAL SIGNS –

SPECIAL ROOMS SERIES

I022THEATRE ROOM IDENTIFICATION

Sheet 2 of 2

GRAPHIC DETAILS

Scale 1:5

G23 Lecture TheatreG23 Lecture Theatre

Lecture Theatre

G23

Audio and visual recording may occur in this room. Discussions conducted in the room may be captured.audio and visual recording may ocur

in this room. discussions conducted in

the room may be captured.

FRONT ELEVATION SCALE 1:5

6028

1623

35 35

152

GRAPHIC DETAILS

BUILDING LEVEL Typeface: National Bold

ROOM NUMBER Typeface: National Bold

ROOM NAME Typeface: National Regular Colour: MQ Charcoal

DISCLAIMER TEXT Typeface: National Regular Colour: MQ Charcoal

TACTILE TEXT Typeface: National Regular Colour: MQ Charcoal

PANEL BACKGROUND Colour: MQ White

BRAILLE Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

Note: Side profile to be as slim as possible whilst still ensuring structural integrity and accounting for given technology requirements.

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

062 Part Seven Signage Design - Internal

SIGN TYPES IN DETAIL INTERNAL SIGNS – SPECIAL ROOMS SERIES

SPECIAL ROOM IDENTIFICATION – FLAG

Sheet 1 of 4

ELEVATIONS

Scale 1:20

I024

Sign use: To identify a special room

Location: Above the door to the room

Typical content: – Building level– Room number– Room type/name

FRONT ELEVATION SCALE 1:20

Building level and room number laser cut into aluminium two-pack polyurethane facade

to reveal Victorian Ash timber.

Victorian Ash timber detail.Concealed fixtures. Vinyl messaging

applied.

FRONTSIDE

220

016

0

100

30 267

G23Teaching Room

Part Seven Signage Design - Internal 063

SIGN TYPES IN DETAIL INTERNAL SIGNS –

SPECIAL ROOMS SERIES

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SPECIAL ROOM IDENTIFICATION – FLAG

Sheet 2 of 4I024

ELEVATIONS

Scale 1:10

FRONT ELEVATION SCALE 1:10

SIDE

RIGHT ALIGNED FRONT

LEFT ALIGNED FRONT

G23Teaching RoomTeaching Room

G23

064 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – SPECIAL ROOMS SERIES

SPECIAL ROOM IDENTIFICATION – FLAG

Sheet 3 of 4

GRAPHIC DETAILS

Scale 1:5

I024

GRAPHIC DETAILS

BUILDING LEVEL Typeface: National Bold

ROOM NUMBER Typeface: National Bold

ROOM NAME Typeface: National Regular Colour: MQ White

PANEL BACKGROUND Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

FRONT ELEVATION SCALE 1:5

1518

14

20 20

1518

14

20 20

G23Teaching Room

Teaching Room

66

G23 66

Part Seven Signage Design - Internal 065

SIGN TYPES IN DETAIL INTERNAL SIGNS –

SPECIAL ROOMS SERIES

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

GRAPHIC DETAILS

Scale 1: 5

SPECIAL ROOM IDENTIFICATION – FLAG

Sheet 4 of 4I024

FRONT ELEVATION SCALE 1:5

15

14

20 20

52

18

46

G8742Teaching Room

15

14

20 20

52

18

B2300Teaching Room

066 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – AMENITY SERIES

AMENITY IDENTIFICATION

Sheet 1 of 6I026

FRONT ELEVATION SCALE 1:20

100

130

5

First and preferred location on wallnext to door, on same side asdoor handle

Third preferred location(only if first and second

locations are not possible)centred on door

Second preferred location(only if first location is not

possible) on wall next todoor on hinge side

Male ToiletMale Toilet

100

ELEVATIONS

Scale 1:20

Part Seven Signage Design - Internal 067

SIGN TYPES IN DETAIL INTERNAL SIGNS –

AMENITY SERIES

AMENITY IDENTIFICATION

Sheet 2 of 6

ELEVATIONS

Scale 1:20

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

I026

Sign use: To identify an amenity

Location: Alongside the door to the amenity. As per code requirements to achieve 30% contrast between panel and background surface two options have been designed. Select MQ White or MQ Charcoal panel option to suit specific condition.

Typical content: – International symbol (male/female/accessible)– Braille and tactile type

FRONT ELEVATION SCALE 1:20

Male ToiletMale Toilet

Braille (white) and tactile (charcoal).

White matt acrylic. Pictogram MQ Charcoal / Black - Preference is Charcoal. Raised from surface by 1mm.

FRONT SIDE

White matt acrylic

267

100 160 27

130

5

068 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – AMENITY SERIES

AMENITY IDENTIFICATION

Sheet 3 of 6I026

ELEVATIONS

Scale 1:20

FRONT ELEVATION SCALE 1:20

Male ToiletMale Toilet

Braille (charcoal) and tactile (White).

Aluminium two-pack polyurethane facade.Graphics MQ White.

FRONT SIDE

Charcoal matt acrylic

267

100 160 27

130

5

Male ToiletMale Toilet

Part Seven Signage Design - Internal 069

SIGN TYPES IN DETAIL INTERNAL SIGNS –

AMENITY SERIES

AMENITY IDENTIFICATION

Sheet 4 of 6

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

I026

FRONT ELEVATION

Scale 1:20

DOOR LOCATED SIGNAGE

For ambulant accessible sanitary facility.

FRONT ELEVATION SCALE 1:20

Female Ambulant ToiletFemale ambulant Toilet

Braille (blue) and tactile (white).

Aluminium two-pack polyurethane facade.Graphics MQ White vinyl raised from surface.

100

130

526

7

160

070 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – AMENITY SERIES

AMENITY IDENTIFICATION

Sheet 5 of 6I026

FRONT ELEVATION

Scale 1:20

DIRECTIONAL SIGNAGE

Where a sanitary facility does not provide accessible unisex facilities use this directional signage to direct users to appropriate facility.

FRONT ELEVATION SCALE 1:20

Unisex ToiletUnisex Accessible Toilet

Male ToiletMale Toilet

100 40

Part Seven Signage Design - Internal 071

FRONT ELEVATION SCALE 1:5

Male ToiletMale Toilet

Unisex Toilet RH Unisex Accessible Toilet RH

Female Ambulant ToiletFemale ambulant Toilet

Indicates left hand (LH) or right hand (RH) use

144

15

832

27

15

Male ToiletMale Toilet

144

15

832

27

15

1514

415

15

832

27320

15

144

15

832

27

SIGN TYPES IN DETAIL INTERNAL SIGNS –

AMENITY SERIES

AMENITY IDENTIFICATION

Sheet 6 of 6

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

I026

GRAPHIC DETAILS

Scale 1:20

GRAPHIC DETAILS

TACTILE PICTOGRAM Colour: MQ Charcoal / Black - Preference is Charcoal Height: 144mm

TACTILE PICTOGRAM ALTERNATIVE Colour: MQ White Height: 144mm

TACTILE TEXT Typeface: National Regular Standard colour: MQ Charcoal on MQ White background Accessibility colour: MQ White

TACTILE TEXT ALTERNATIVE Typeface: National Regular Standard colour: MQ White on MQ Charcoal background Accessibility colour: MQ White

BRAILLEBraille text to be white on all panels.

TACTILE + BRAILLETo be as required by relevant AS and BCA.

ACCESSIBLE AMENITIES Colour: MQ White on B21 Ultramarine background

BRAILLEBraille text to be white on all panels.

TACTILE + BRAILLETo be as required by relevant AS and BCA.

ACCESSIBLE AMENITIES Colour: MQ White on B21 Ultramarine background

072 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – AMENITY SERIES

AMENITY IDENTIFICATION – FLAG

Sheet 1 of 8I030

ELEVATIONS

Scale 1:20

Sign use: To identify an amenity

Location: Above the door to the amenity

Typical content: – International symbol (male/female/accessible)

ELEVATIONS SCALE 1:20

220

016

0

100

30 267

Pictogram/amenity name laser cutinto aluminium two-pack

to reveal Victorian Ash timber.

Victorian Ash timber detail.Concealed fixtures.

FRONTSIDE

Part Seven Signage Design - Internal 073

SIGN TYPES IN DETAIL INTERNAL SIGNS –

AMENITY SERIES

AMENITY IDENTIFICATION – FLAG

Sheet 2 of 8

ELEVATIONS

Scale 1:10

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

I030

ELEVATIONS SCALE 1:10

SIDE

RIGHT ALIGNED FRONT

LEFT ALIGNED FRONT

074 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – AMENITY SERIES

AMENITY IDENTIFICATION – FLAG

Sheet 3 of 8I030

GRAPHIC DETAIL LEFT

Scale 1:5

LEFT ALIGNMENT SCALE 1:5

Kitchen

120

2020

26

120

2020

26

120

2020

20 20

35

2020

26

GRAPHIC DETAILS

PICTOGRAM Height: 120mm

AMENITY NAME Typeface: National Bold

STANDARD PANEL Colour: MQ White

ACCESSIBLE PANEL Colour: MQ White on B21 Ultramarine background

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

Part Seven Signage Design - Internal 075

SIGN TYPES IN DETAIL INTERNAL SIGNS –

AMENITY SERIES

AMENITY IDENTIFICATION – FLAG

Sheet 4 of 8

GRAPHIC DETAIL RIGHT

Scale 1:5

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

I030

GRAPHIC DETAILS

PICTOGRAM Height: 120mm

AMENITY NAME Typeface: National Bold

STANDARD PANEL Colour: MQ White

ACCESSIBLE PANEL Colour: MQ White on B21 Ultramarine background

RIGHT ALIGNMENT SCALE 1:5

Kitchen

120

2020

26

120

2020

26

120

2020

20 20

35

2020

26

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

076 Part Seven Signage Design - Internal

SIGN TYPES IN DETAIL INTERNAL SIGNS – AMENITY SERIES

AMENITY IDENTIFICATION – FLAG (OPTION)

Sheet 5 of 8I030

ELEVATIONS

Scale 1:20

Sign use: To identify an amenity

Location: Above the door to the amenity

Typical content: – International symbol (male/female/accessible)

ELEVATIONS SCALE 1:20

220

016

0

100

30 267

Pictogram/amenity MQ Charcoal / BlackPreference is Charcoal for pictogram and amenity name.

White matt acrylic

FRONTSIDE

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 077

SIGN TYPES IN DETAIL INTERNAL SIGNS –

AMENITY SERIES

AMENITY IDENTIFICATION – FLAG (OPTIONAL)

Sheet 6 of 8

ELEVATIONS

Scale 1:10

I030

ELEVATIONS SCALE 1:10

SIDE

RIGHT ALIGNED FRONT

LEFT ALIGNED FRONT

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

078 Part Seven Signage Design - Internal

SIGN TYPES IN DETAIL INTERNAL SIGNS – AMENITY SERIES

AMENITY IDENTIFICATION – FLAG (OPTIONAL)

Sheet 7 of 8I030

GRAPHIC DETAIL LEFT

Scale 1:5

LEFT ALIGNMENT SCALE 1:5

Kitchen

120

2020

26

120

2020

26

120

2020

20 20

35

2020

26

GRAPHIC DETAILS

PICTOGRAM Height: 120mm Colour: MQ Charcoal / Black - Preference is Charcoal

AMENITY NAME Typeface: National Bold

STANDARD PANEL Colour: MQ White

ACCESSIBLE PANEL Colour: MQ White on B21 Ultramarine background

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 079

SIGN TYPES IN DETAIL INTERNAL SIGNS –

AMENITY SERIES

AMENITY IDENTIFICATION – FLAG

Sheet 8 of 8

GRAPHIC DETAIL RIGHT

Scale 1:5

I030

GRAPHIC DETAILS

PICTOGRAM Height: 120mm Colour: MQ Charcoal / Black - Preference is Charcoal

AMENITY NAME Typeface: National Bold

STANDARD PANEL Colour: MQ White

ACCESSIBLE PANEL Colour: MQ White on B21 Ultramarine background

RIGHT ALIGNMENT SCALE 1:5

Kitchen

120

2020

26

120

2020

26

120

2020

20 20

35

2020

26

080 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – ROOM SERIES

ROOM NUMBER IDENTIFICATION

Sheet 1 of 4I032

ELEVATIONS

Scale 1:20

Sign use: Identify the room and the individual

Location: Alongside the door

Typical content: – Braille and tactile type room number– Faculty/Department/Office– Individuals name

FRONT ELEVATION SCALE 1:20

00000

Mr John MooreFaculty of Business and Economics

00000

Mr John MooreFaculty of Business and Economics17

5

105 13

1213

3mm white gloss acrylic panel

3mm sliding panel - etching substrate with black backing. Name and description etched to reveal white.

10mm black acrylic backing panel

Tactile type set in National Bold typeface - MQ BlackBraille - White

FRONT SIDE

Part Seven Signage Design - Internal 081

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ROOM SERIES

ROOM NUMBER IDENTIFICATION

Sheet 2 of 4

ELEVATIONS

Scale 1:20

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

I032

FRONT ELEVATION SCALE 1:20

00000

Mr John MooreFaculty of Business and Economics

13

1213

105

3mm white gloss panel.

3mm sliding panel - etching substrate with black backing. Name and description etched to reveal white.

00000

Mr John MooreFaculty of Business and Economics

10mm white acrylic backing panel

Tactile type set in National Bold typeface - MQ Black

Braille - White

FRONT SIDE

082 Part Seven Signage Design - Internal

FRONT ELEVATION SCALE 1:20

00000

Mr John MooreFaculty of Business and Economics

1213

100100

First and preferred location on wallnext to door, on same side asdoor handle

Second preferred location(only if first location is not

possible) on wall next todoor on hinge side

Third preferred location(only if first and second

locations are not possible)centred on door

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – ROOM SERIES

ROOM NUMBER IDENTIFICATION

Sheet 3 of 4I032

FRONT ELEVATION

Scale 1:20

LOCATION

This elevation illustrates the order of preference for sign location

Part Seven Signage Design - Internal 083

GRAPHIC DETAIL

Scale 1:2

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ROOM SERIES

ROOM NUMBER IDENTIFICATION

Sheet 4 of 4

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

I032

GRAPHIC DETAILS

TACTILE ROOM NUMBER Typeface: National Bold Colour: MQ Black

BRAILLE Colour: MQ White

STAFF NAME Typeface: National Regular Colour: White

FACULTY NAME Typeface: National Regular Colour: White

PANEL BACKGROUND Colour: MQ White, MQ Black

FRONT ELEVATION SCALE 1:2

12

8

3 10

65

47

1812

1212

105

5

00000

Mr John MooreFaculty of Business and Economics

084 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 085

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ROOM SERIES

FRONT ELEVATION

Scale 1: 20

HEARING LOOP IDENTIFICATION

Sheet 1 of 4I035

FRONT ELEVATION SCALE 1:20

Hearingloop

Option 1

White matt acrylic. Pictogram B21 Ultramarine. Raised from surface by 1mm.

Braille and tactile.

1213

Option 1

Sign use: To identify the location and type of hearing loop in operation within a specific room.

The content illustrated below indicates a Audio Induction Loop System.

Location: To be located as per AS guidelines and aligned with the broader University strategy in relation to the operation of the hearing assistance across campus.Typical content: Derived from AS1428 as per the type of hearing assistance system that is in use.

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

086 Part Seven Signage Design - Internal

SIGN TYPES IN DETAIL INTERNAL SIGNS – ROOM SERIES

HEARING LOOP IDENTIFICATION

Sheet 2 of 4I035

FRONT ELEVATION

Scale 1: 20FRONT ELEVATION SCALE 1:20

This theatre is fitted with an Infa Red (IR) assistive induction loop assistive listening system.

To use this system, ask for IR receiver, and use hearing aid T-switch if you have one.

This room is fitted with an audio

frequency induction loop assistive

listening system.

To use this system,

ask for Loop receiver, and/or use

hearing aid T-switch if you

haveasass

Option 2

Braille and tactile.

1213

Option 2

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

Part Seven Signage Design - Internal 087

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ROOM SERIES

GRAPHIC DETAILS

TACTILE TEXT Typeface: National RegularColour: B21 Ultramarine

TACTILE PICTOGRAMHeight: 100mmColour: B21 Ultramarine onMQ white background

BRAILLEColour: MQ White

PANEL BACKGROUND Colour: MQ White

NOTE: The content illustrated indicates a Audio Induction Loop System.

GRAPHIC DETAILS

Scale 1:2

HEARING LOOP IDENTIFICATION

Sheet 3 of 4 I035

FRONT ELEVATION SCALE 1:2

Hearingloop

100

1015

100

3 3

37

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

088 Part Seven Signage Design - Internal

HEARING LOOP IDENTIFICATION

Sheet 4 of 4

SIGN TYPES IN DETAIL INTERNAL SIGNS – ROOM SERIES

I035

GRAPHIC DETAILS

Scale 1: 2

FRONT ELEVATION SCALE 1:2

24 24

This Theatre is fitted with an Infra red (IR) assistive listening system.

To use this system, ask for IR receiver, and use hearing aid T-switch if you have one.This room is fitted with an audio

frequency induction loop assistive

listening system.

To use this system,

ask for Loop receiver, and/or use

hearing aid T-switch if you have

one.

2026

2610

0

GRAPHIC DETAILS

TACTILE PICTOGRAM Height: 100mmColour: B21 Ultramarine onMQ white background

TACTILE TEXT Typeface: National RegularColour: B21 Ultramarine on MQ White

BRAILLEColour: MQ White

PANEL BACKGROUND Colour: MQ White

CONSTRUCTION DETAILS For an example of typical construction method refer to Section 08

Part Seven Signage Design - Internal 089

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ROOM SERIES

LAB ROOM NUMBER WITH HAZARD INFORMATION

Sheet 1 of 2

ELEVATIONS

Scale 1:20

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

I036

FRONT ELEVATION SCALE 1:20

In Case Of Emergency Dial 9999

Femtosecond Direct Write Facility

0 2- 0 0 0

00000Contact:Name Name 0000 000 000

Hazardous substances in this area. Do not enter without approval. hazardous substances in this area. Do

not enter without approval.

300

500

130

5

100

Tactile type set in National Regular - BlackBraille - White

FRONT SIDE

13

white matt acrylic panel

Text and pictograms digitally printed onto substrate.

Sign use: Identify a lab room. Provide hazard and safety information

Location: Alongside the door

Typical content: – Braille and tactile text room number– Faculty/Department/Lab– Hazard/safety information– Emergency contact info

090 Part Seven Signage Design - Internal

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

SIGN TYPES IN DETAIL INTERNAL SIGNS – ROOM SERIES

LAB ROOM NUMBER WITH HAZARD INFORMATION

Sheet 2 of 2I036

GRAPHIC DETAILS

Scale 1:5

GRAPHIC DETAILS

TACTILE ROOM NUMBER Typeface: National Regular Colour: MQ Charcoal / Black

BRAILLE Colour: MQ White

FACULTY NAME Typeface: National Regular Colour: MQ Charcoal / Black

HAZARDS, SAFETY & EMERGENCY CONTACT DETAILS Typeface: National Regular Colour: MQ Charcoal / Black

HAZARD & SAFETY PICTOGRAMS Height: 55mm / 30mm

PANEL BACKGROUND Colour: MQ White

FRONT ELEVATION SCALE 1:5

21 13

4015

915

368

1855

2028

1313

767

6450

60

In Case Of Emergency Dial 9999

Femtosecond Direct Write Facility

0 2- 0 0 0

00000Contact:Name Name 0000 000 000

Hazardous substances in this area. Do not enter without approval. hazardous substances in this area. Do

not enter without approval.

Part Seven Signage Design - Internal 091

SIGN TYPES IN DETAIL INTERNAL SIGNS –

ROOM SERIES

ROOM PIN BOARD

Sheet 1 of 1

ELEVATIONS

Scale 1:20

Macquarie University Signage and Wayfinding Guideline Issue 3 Prepared by Citizen Group

I039

Sign use: Provide an area for information to be displayed

Location: Alongside the door and room number

Typical content: – Information relevant to the use of the room

FRONT ELEVATION SCALE 1:20

00000

Mr John MooreFaculty of Business and Economics

1213

100

300

500

50

10

Aluminium two-pack polyurethane frame (MQ White).Concealed fixtures.

Inset EchoPanel (Grey 442).