5/3/2019 - revised - r.j. corman railroad group · 2019. 5. 3. · 13. flashing light signals to be...

20
R. J. Corman Equipment Company, LLC • R. J. Corman Railroad/Ashland, LLC • R. J. Corman Railroad Company/Allentown Lines, Inc. R. J. Corman Railroad Company/Bardstown Line • R. J. Corman Railroad Company/Carolina Lines, LLC • R. J. Corman Railroad Company/Central Kentucky Lines, LLC R. J. Corman Railroad Company/Cleveland Line, Inc. • R. J. Corman Railroad Company/Material Sales • R. J. Corman Railroad Company/Memphis Line R. J. Corman Railroad Company/Pennsylvania Lines, Inc. • R. J. Corman Railroad Company/Tennessee Terminal, LLC • R. J. Corman Railroad Company/Texas Lines, LLC R. J. Corman Railroad Company/Western Ohio Line, Inc. • R. J. Corman Railroad Services, LLC • R. J. Corman Distribution Centers, LLC • R. J. Corman Railroad Group, LLC R. J. Corman Railroad Switching Company, LLC • R. J. Corman Real Estate, LLC • R. J. Corman Restaurant Corporation • R. J. Corman Signaling, LLC 5/3/2019 - REVISED Vendors, You are invited to submit a bid to provide a crossing materials package for the highway grade crossing listed below: Mt. Pleasant Road, Strasburg, OH, DOT# 142 594T, as shown on attached signal plans Enclosed bid package also includes material requirements, as well as bidding guidelines. All bids must be submitted on company letterhead and received by May 17, 2019 at 5:00 pm EST. Please submit via email to [email protected]. If you have any questions regarding this bid request, please don't hesitate to contact me. Vendor to provide material delivery to 401 Enterprise Drive, Nicholasville, KY 40356. RJ CORMAN WILL PROVIDE WIRING AND INSTALLATION. Shipping to begin as soon as possible but no later than 90 days ARO. Sincerely, Jimmy Kelley R.J. Corman Railroad Group PO Box 788 Nicholasville, KY 40340 O: 859-881-6637 www.rjcorman.com

Upload: others

Post on 31-Jan-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • R. J. Corman Equipment Company, LLC • R. J. Corman Railroad/Ashland, LLC • R. J. Corman Railroad Company/Allentown Lines, Inc. R. J. Corman Railroad Company/Bardstown Line • R. J. Corman Railroad Company/Carolina Lines, LLC • R. J. Corman Railroad Company/Central Kentucky Lines, LLC

    R. J. Corman Railroad Company/Cleveland Line, Inc. • R. J. Corman Railroad Company/Material Sales • R. J. Corman Railroad Company/Memphis Line R. J. Corman Railroad Company/Pennsylvania Lines, Inc. • R. J. Corman Railroad Company/Tennessee Terminal, LLC • R. J. Corman Railroad Company/Texas Lines, LLC R. J. Corman Railroad Company/Western Ohio Line, Inc. • R. J. Corman Railroad Services, LLC • R. J. Corman Distribution Centers, LLC • R. J. Corman Railroad Group, LLC

    R. J. Corman Railroad Switching Company, LLC • R. J. Corman Real Estate, LLC • R. J. Corman Restaurant Corporation • R. J. Corman Signaling, LLC

    5/3/2019 - REVISED Vendors, You are invited to submit a bid to provide a crossing materials package for the highway grade crossing listed below:

    Mt. Pleasant Road, Strasburg, OH, DOT# 142 594T, as shown on attached signal plans

    Enclosed bid package also includes material requirements, as well as bidding guidelines. All bids must be submitted on company letterhead and received by May 17, 2019 at 5:00 pm EST. Please submit via email to [email protected]. If you have any questions regarding this bid request, please don't hesitate to contact me. Vendor to provide material delivery to 401 Enterprise Drive, Nicholasville, KY 40356.

    RJ CORMAN WILL PROVIDE WIRING AND INSTALLATION. Shipping to begin as soon as possible but no later than 90 days ARO.

    Sincerely, Jimmy Kelley R.J. Corman Railroad Group PO Box 788 Nicholasville, KY 40340 O: 859-881-6637 www.rjcorman.com

    mailto:[email protected]://na01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.rjcorman.com%2F&data=01%7C01%7CDan.Jenkins%40RJCorman.com%7C292d4f69a95b45d76ede08d467eb01b1%7Cd069aaaef47a4471baf7424c4c77794f%7C1&sdata=EJo5jmOkdBWlGHNRup%2F%2FrnawLiWSZoDCW728TUb7Hkc%3D&reserved=0

  • R. J. Corman Equipment Company, LLC • R. J. Corman Railroad/Ashland, LLC • R. J. Corman Railroad Company/Allentown Lines, Inc. R. J. Corman Railroad Company/Bardstown Line • R. J. Corman Railroad Company/Carolina Lines, LLC • R. J. Corman Railroad Company/Central Kentucky Lines, LLC

    R. J. Corman Railroad Company/Cleveland Line, Inc. • R. J. Corman Railroad Company/Material Sales • R. J. Corman Railroad Company/Memphis Line R. J. Corman Railroad Company/Pennsylvania Lines, Inc. • R. J. Corman Railroad Company/Tennessee Terminal, LLC • R. J. Corman Railroad Company/Texas Lines, LLC R. J. Corman Railroad Company/Western Ohio Line, Inc. • R. J. Corman Railroad Services, LLC • R. J. Corman Distribution Centers, LLC • R. J. Corman Railroad Group, LLC

    R. J. Corman Railroad Switching Company, LLC • R. J. Corman Real Estate, LLC • R. J. Corman Restaurant Corporation • R. J. Corman Signaling, LLC

    Scope: Vendor will provide all necessary equipment, inside and outside, of the shelter per the attached Signal drawing. General Design Guidelines:

    1. Material shall comply with all applicable FRA and state regulations and follow current AREMA C&S Manual for Recommended Practices.

    2. All material provided shall be new.

    Material Requirements:

    1. Bungalow should be PTMW 6x6 Aluminum – 91000539 C-1 2. Wall mount 115V 1500W heater w/built in thermostat. 3. Train detection will be provided by Siemens MS-4000 Dual Single-Track System with user

    reference manual. 4. Flasher control will be provided by the Siemens 40amp Crossing Controller. Provide associated

    Lightning/Surge Arrester panel(s). See plans for details. 5. On the main terminal board, no equipment or terminals (other than ground buss) will be lower

    than 12” above floor 6. Relays will be Siemens ST Style “B” (if needed) 7. Chargers – NRS ELC 12/20 M-D or 12/40 M-D as applicable 8. Batteries – Sealed, Maintenance Free, Lead Acid Batteries 9. Emergency Switch Box Assembly – L&W 2 Position – 3A900436 10. Gate mechanisms to use WCH 3593-E-131. Shall include the following as designed per mast:

    a. 19' - 32' GATE ARMS W/ LED LIGHTS b. 5" BASE (DOUBLE JUNCTION BOX) & 16’5” MAST c. 2-WAY LED FLASHER ASSEMBLIES d. COUNTERWEIGHT KIT e. CROSSBUCK AND ASSOCIATED MOUNTING HARDWARE f. HIGH WIND BRACKET g. ELECTRONIC BELL (if needed) to be Electronic Loud Tone without sensor h. GATE HEATERS (WCH) 115v i. BI-DIRECTIONAL GATE KEEPER

    11. Foundations to be galvanized helical by Dixie Precast. 12. Berm Wall to be Dixie Precast steel wall 4’ x 15’ SRW4WR. 13. Flashing light signals to be 12” LED heads (Miller Felpax) with aluminum visors and backgrounds. 14. Rail Shunt Augmenter – Genesis P/N 08033-2000 15. Insulated joints 16. Vendor to provide all field equipment, including track wire, shunts, rail bonding material, etc. 17. Jointed Rail to be Bonded within approaches please include all associated field materials

    required.

  • R. J. Corman Equipment Company, LLC • R. J. Corman Railroad/Ashland, LLC • R. J. Corman Railroad Company/Allentown Lines, Inc. R. J. Corman Railroad Company/Bardstown Line • R. J. Corman Railroad Company/Carolina Lines, LLC • R. J. Corman Railroad Company/Central Kentucky Lines, LLC

    R. J. Corman Railroad Company/Cleveland Line, Inc. • R. J. Corman Railroad Company/Material Sales • R. J. Corman Railroad Company/Memphis Line R. J. Corman Railroad Company/Pennsylvania Lines, Inc. • R. J. Corman Railroad Company/Tennessee Terminal, LLC • R. J. Corman Railroad Company/Texas Lines, LLC R. J. Corman Railroad Company/Western Ohio Line, Inc. • R. J. Corman Railroad Services, LLC • R. J. Corman Distribution Centers, LLC • R. J. Corman Railroad Group, LLC

    R. J. Corman Railroad Switching Company, LLC • R. J. Corman Real Estate, LLC • R. J. Corman Restaurant Corporation • R. J. Corman Signaling, LLC

    Performance & Bidding Guidelines: Bids should be detailed in the following format: LOCATION: ____________________________________ Material Cost $______________________ Estimated Freight/Shipping Cost $______________________ Estimated Taxes Cost $______________________ Total Cost $______________________ Case & Other Material Shipping Date ________________days ARO

  • INDEX SHEET

    REVISIONS

    1

    IN SERVICE:

    PER:XXX

    XX-XX-XX

    XXX XXX

    RWMRJCMGH

    PROJECT:

    03/20/19SH.

    NO.

    1

    2

    3

    4

    5

    6

    7

    8

    9

    12

    13

    14

    15

    CONTENTS

    NX1 INDEX SHEET

    HOUSE SIDE A LAYOUT

    TRACK PLAN

    TRACK LAYOUT

    LOAD CENTER WIRING

    CONNECTORS FOR TRACK MODULE

    CROSSING CONTROLLER HOOK-UP

    LIGHTING/SURGE PANEL HOOK-UP

    TERMINAL BOARD

    16

    HOUSE SIDE B LAYOUT

    HOUSE SIDE C LAYOUT

    PROFILE

    DC POWER

    MS 4000 GCP

    HOUSE SIDE D LAYOUT & TOP VIEW

    1

    REV

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    NX1

    DATE:

    FILE:

    SHEET

    CL07730.NX1

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

    18CL-SIGMTPLEAS

    110

    111

    GATE & FLASHER CIRCUITS SIGNAL "A"

    GATE & FLASHER CIRCUITS SIGNAL "B"

    W/ FLASHERS AND GATES.

    ALL NEW 6'X6' BUNGALOW,

    Ohio Utilities Protection Service

    Call 811before you dig

  • TRACK PLAN

    SCALE 1" = 20'

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    01

    DATE:

    FILE:

    SHEET

    CL07730.01

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

    1.

    2.

    CONSTRUCTION NOTES:

    HOUSE DOOR TO FACE ROAD.

    CONSTRUCTION NOTES:

    R.O.W.

    ~~

    R.O.W.

    ~~

    SERVICE

    AC

    MS 4000

    T1

    645 HZ10.0 KHZ

    16'

    16'

    RT-OF-WAY)(IF ADEQUATENEAREST RAILMINIMUM FROM

    35'

    52°

    35'

    20'

    24'

    NORT

    H

    NORTH SOUTHM.P. DECREASINGM.P. INCREASING

    TO WARWICK TERMINAL

    4.

    AFTER INSTALLATION.

    FIELD TO CONFIRM ALL DISTANCES

    W/ BELLSIG "A"

    SIG "B"

    MIN.4'-3"

    31' +/-

    MIN.4'-3"

    31' +/-

    15'

    15'

    CHAIN LINK FENCE

    30'

    #142 594T

    MT. PLEASANT RD

    CHAIN LINK FENCE

    TO END OF TRACK

    10' BERM WALL

    3.

    FILL ROCK/DIRT.

    IN SE QUAD FOR BUNGALOW. APPROX. 20T OF

    DIXIE PRECAST BERM WALL TO BE INSTALLED

    7' HELICAL GATE FOUNDATIONS.

    WITH THE RAILROAD.

    RAILROAD TO DO CURB WORK, COORDINATE

    BE TYPE 6, REFER TO DWG. #BP-5.1.

    INSTALL GATES AT 4'-3" MIN. CURB TO

    NEW CURB WORK AT GATE QUADS TO

    BD

    C

    A

    6'X6'

    Ohio Utilities Protection Service

    Call 811before you dig

  • GCP WIRES

    TO NEAREST

    GCP WIRES

    TO NEAREST

    FLGS

    1544' 1544'

    R T

    PROFILE

    TO

    C L

    TO

    C L

    C L

    W/BELL

    FLGS

    APPROACH CALCULATION INFORMATION

    TIME TABLE MAXIMUM TRAIN SPEED IN MILE PER HOUR

    DESIGNED WARNING TIME FOR TRAINS AT T.T. SPEED

    DESIGNED DETECTION TIME FOR TRAINS AT T.T. SPEED

    25

    04

    01

    00

    30

    00

    05

    35

    25

    05

    STANDARD MINIMUM WARNING TIME IN SECONDS

    ROADWAY GATE TIME IN SECONDS

    CLEARANCE TIME IN SECONDS

    DOT TRAFFIC LIGHT SIMULTANEOUS PREEMPT IN SECS

    DOT TRAFFIC LIGHT ADVANCE PREEMPT IN SECS

    CONTROL EQUIPMENT REACTION TIME IN SECONDS

    BUFFER IN MILE PER HOUR

    1.47

    1544'APPROACH DISTANCE TO ISLAND EDGE IN FEET

    APPROACH SPEED FR CROSSING CALCULATION (AS)

    APPROACH DISTANCE FORMULA: TTxASx1.47

    30

    0'

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    02

    DATE:

    FILE:

    SHEET

    CL07730.02

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

    #142 594T

    MT. PLEASANT RD

    62'

    62'

    SOUTHM.P. DECREASING

    END OF TRACKTO

    NORTHM.P. INCREASING

    TO WARWICK TERMINAL

    T1T1

    645 HZ

    10.0 KHZ

    MS 4000

    A A

    A NBS-1 62775-3497 (645HZ)

  • TRACK LAYOUT

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    03

    DATE:

    FILE:

    SHEET

    CL07730.03

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

    RCV-2

    RCV-1

    120' MINIMUM

    2G

    2G 1G

    1G T

    T

    4

    4 3

    3

    2

    2 1

    1

    50' MINIMUM50' MINIMUM

    UG-4

    UG-1 & UG-1A

    SIG "B"

    XMT-2

    XMT-1

    6'X6'

    UG-5

    UG-1 & UG-1A

    UG-4

    UG-3

    UG-2 & UG-2A

    SERVICE

    AC

    CONDUIT10' X 4"

    CONDUIT40' X 4"

    W/ BELLSIG "A"

    UG-4-TW. PR. #6

    UG-5-TW. PR. #6

    UG-3-3CUG #2

    W/#6 GND

    RCV-2

    RCV-1

    XMT-2

    XMT-1

    UG-1-7CUG #6 UG-2-7CUG #6

    UG-1A-7CUG #14 UG-2A-7CUG #14

    SPARE 1

    NX110

    BX110

    GP1

    GP

    ABELL

    AGC

    SPARE 2

    SPARE 1

    AN16

    AB16

    AEB

    AEZ

    AEC

    SPARE 2

    SPARE 1

    BN16

    BB16

    BEB

    BEZ

    BEC

    SPARE 2

    SPARE 1

    NX110

    BX110

    BB16

    GP2

    BGC

    GND

    NX120

    BX120-B

    BX120-A

  • LOAD CENTER WIRING (120V)

    LOAD CENTER

    INTERLOCKED SWITCH

    BREAK BEFORE MAKE

    30A

    11

    15A

    15A

    EPD120/240TDFLERICO

    5

    2

    7

    4

    9

    6

    8

    100A

    |

    UG-3

    |

    1

    100A3

    10

    12

    30A

    30A

    1413

    15 16

    GND #6

    BX120-A #2

    NX120 (NEUTRAL) #2

    NEUTRAL BAR

    LOAD CENTER

    GND.

    #6

    WHIT

    E#6

    WHIT

    E

    RE

    D

    GRN/YELE

    QUIP

    GN

    D

    BU

    SS

    L1

    L2

    G

    N

    15A GFI

    30A

    BL

    WH

    SHEET

    NEXT

    TO

    EQUIPMENT IN THIS HOUSE.DO NOT USE OR INSTALL 240VAC

    NX120

    NOTE:

    #16

    IS TO BE PROPERLY GROUNDED.

    ALL AC 120V AND 240V EQUIPMENT

    CONDUIT WITH NO EXPOSED TERMINALS.

    ALL AC WIRING IS TO BE IN METALLIC

    UNLESS NOTED OTHERWISE.

    ALL WIRING TO BE #10AWG

    10A 2P CIR BKR QO210

    SQUARE "D" PART NUMBERS:

    LOAD CENTER

    10A 1P CIR BKR

    MECH INTERLOCK

    QO116L125G

    QO120

    QO110

    PK4DTIM4LA

    QO130

    20A 1P CIR BKR

    30A 2P CIR BKR

    QO260

    QO230

    100A 2P CIR BKR QO2100

    60A 2P CIR BKR

    30A 1P CIR BKR

    15A 1P CIR BKR QO115

    15A 1P GFI CIR BKR QO115GFI

    BX120-A #10

    NX120 #10

    GND #10

    X

    WG

    GEN. PLUG

    NEMA L5-30P

    OUTSIDE HOUSE

    MOUNTED

    15A

    12

    EG12

    N12

    BX120-A12

    GND

    NX120

    15A

    HEATERWALL

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    04

    DATE:

    FILE:

    SHEET

    CL07730.04

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

    15A GFI

    30A

    10A

    BD25 L

    L

    L

    L

    BD26BD28

    BD29

    UG-1A

    UG-2A

    UG-1A

    UG-2A

    BX120-B

    NX120-B

    14

    EG14

    N14

    BX120-A11

    NX120

    SHEET 7

    TO

    N11

    EG11

    10A11

    AS REQUIRED

    HOUSE LIGHTS

    15A

    N1

    EG1

    1

    LIG

    HT

    LIG

    HT

    BX120-A1

    NX120

    GND

    SW.HOUSE LIGHT

    VENT

    FAN

    915A

    EG9

    THERMOSTAT

    N9NX120

    BX120-A9

    GND

    10

    MOUNTED ONSIDE "D"

    RECEPTACLE

    DUPLEX

    EG10

    N10

    15A GFI

    BX120-A10

    GND

    NX120

    30A

    N5

    EG5

    5

    GND

    NX120

    BX120-A5

    RECEPTACLES

    NEMA L5-30R

    A WALL

    SHEET

    NEXT

    TOBX120-B7A

    30A

    N7

    EG7

    7

    RECEPTACLES

    NEMA L5-30R

    C WALL

    GND

    NX120

    BX120-B7

    #16|BX120-B #2

    120/240 VAC

    POWER SERVICE

    FROM METER

  • DC POWER

    SHEET 9

    TO

    B12R

    N12R

    B16R

    N16R

    B16

    N16

    NX120 SHEET

    PREVIOUS

    TO

    #16

    #16

    #16BB4

    BB5

    BB7

    BB8

    BLUE

    RED

    BLACK N12#16 SHEET 8

    TO

    B12

    #16

    BLUE NX120#16

    #16BX120

    CONDUIT CONDUIT

    RED

    BLACK

    WHITE

    GREEN

    POA

    XCA

    BX120-B7A

    N12B

    B12B

    NX120 #14BX120 #14

    GND #14

    CA52

    3C#14

    NX120 #14BX120 #14

    GND #14

    AA52

    3C#14

    PO

    #16

    #16

    PO1

    B12 #16

    XYG

    L5-30

    NEMA PLUG

    XYG

    L5-30

    NEMA PLUG

    B12

    AC DC

    +

    -GND

    ROW B

    SIDE A

    (OR EQUIVALENT)

    NRS ELC-12/20-M-D

    OPENCOMMONCLOSED

    LIGHTPO

    FLEX4C #18 SWITCH

    EMERGENCY

    NC

    NO

    1

    1

    3

    34

    4

    2

    2

    EMERGENCY

    NORMALWAGO

    NOTES:

    UNLESS NOTED OTHERWISE.

    ALL WIRING TO BE #6AWG1.

    2.DO NOT INSTALL 240VAC CHARGERS.

    = TWIST

    E

    AC38

    AD38

    AC42

    AD42

    AC44

    AC49

    AD44

    AD49

    +

    -

    310 A.H.

    6 CELLS 50LF13-RR

    B12 BATT.

    AE12B

    T

    AE14

    AE52 AE54

    + -

    B

    T

    CE14

    CE54

    CE12

    414 A.H.

    7 CELLS 50LF17-RR

    B16 BATT.

    CE52

    #16

    B16

    AC DC

    +

    -GND

    OPENCOMMONCLOSED

    ROW B

    SIDE C

    (OR EQUIVALENT)

    NRS ELC-12/40-M-D

    AC49

    AD45

    AC45

    = 1 INCH TEST LINK

    = INSULATED NUT

    = TEST NUT

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    05

    DATE:

    FILE:

    SHEET

    CL07730.05

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

  • TEMPLATE

    762010010016

    645 HZ

    DIRECTIONALLY WIRED NO

    YES

    ISLAND USED

    INTERNAL

    IN 1.1

    IN 1.2 NOT USED

    PRIME MS/GCP MODE

    POSITIVE START OFF

    SUDDEN SHUNT DET USED NO

    LOW EZ DET USED

    MS SENSITIVITY LEVEL

    COMPENSATION LEVEL

    LOW EX ADJUSTMENT

    INBOUND PS SENSITIVITY

    SPEED LIMITING USED

    OUTBOUND FALSE ACT LVL

    NO

    39

    YES

    NORMAL

    HIGH

    1300

    36

    MS 4000 CONFIGURATION

    ADVANCED

    OTHER

    OOS TIMEOUT

    DAYLIGHT SAVINGS TIME

    EZ/EX LOGGING

    EZ/EX POINT CHANGE

    1 HRS

    ON

    CHANGE

    3

    1

    3

    4

    5

    6 MS PICKUP DELAY

    7

    7A

    8

    UAX USED

    8A

    8B

    9

    10

    11

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    1A (YES ON INITIAL SETUP)

    HIGH

    30 SEC

    ATCS SITE ID

    2

    11A

    12

    MAIN PROGRAM MENU

    APPR FREQUENCY

    APPR TRANSMIT LEVEL

    UNI/BI/SEM-BIDIRNL BIDIRNL

    PRED

    ISL FREQUENCY

    ISL PICKUP DELAY

    PRIME WARNING TIME

    MTF-MS MOTION SENSOR!

    !

    !

    !

    !

    !

    !

    !

    !

    !

    !

    !

    !

    !

    !

    !

    !

    !

    SET TEMPLATE DEFAULTS

    PRIME UAX PICKUP

    (2s+) 3 SECONDS

    PARAMETER VALUE

    15 SEC MCF NAME

    OCCN

    26

    26A

    26B

    26C

    LOCATION

    DOT NUMBER

    MCF AND OCCN

    MILE POST

    SITE NAME

    GCP-T6X-02-9.mcf

    PARAMETER VALUE

    CONTINUE MAIN PROGRAM MENU

    A80490

    LOCOTORP

    +

    -

    +

    -

    B

    N

    MAINT CALL

    GAID

    CPU II+

    KLATNOL

    ECH 1

    ECH 2

    +

    +

    -

    -

    +

    -

    +

    -

    RCV1

    RCV2

    CHK1

    CHK2

    XMT1

    XMT2

    TRK

    TRK

    TRKIN1.1

    IN1.2

    TRACK

    XR

    ISL

    Made in USA

    A80403

    Module

    CPU II+

    SEL

    NAV

    RX/TX

    ECH LAN

    DSPL COMM

    DIAG COMM(CP)

    VLP/CP COMM

    BACKPLANE

    CP HEALTH

    VLP HEALTH

    POWER

    GAID

    PLV

    COMM

    16

    15

    14

    13

    12

    11

    10

    9

    8

    7

    6

    5

    4

    3

    2

    1

    15 16

    2

    4

    6

    8

    10

    12

    1413

    11

    9

    7

    5

    3

    1

    SIEMENS

    A80418

    Module

    TRACK

    S1

    PRIME

    DAX A

    DAX B

    DAX C

    DAX D

    DAX E

    DAX F

    DAX G

    PRE-EMPT

    HEALTH

    POWER

    MOTION

    ISLAND

    OUT 1

    OUT 2

    IN 1

    IN 2

    GAID

    Made in USA

    SIEMENS

    A80403

    Module

    CPU II+

    SEL

    NAV

    RX/TX

    ECH LAN

    DSPL COMM

    DIAG COMM(CP)

    VLP/CP COMM

    BACKPLANE

    CP HEALTH

    VLP HEALTH

    POWER

    GAID

    PLV

    COMM

    16

    15

    14

    13

    12

    11

    10

    9

    8

    7

    6

    5

    4

    3

    2

    1

    15 16

    2

    4

    6

    8

    10

    12

    1413

    11

    9

    7

    5

    3

    1

    Made in USA

    SIEMENS

    A80418

    Module

    TRACK

    S1

    PRIME

    DAX A

    DAX B

    DAX C

    DAX D

    DAX E

    DAX F

    DAX G

    PRE-EMPT

    HEALTH

    POWER

    MOTION

    ISLAND

    OUT 1

    OUT 2

    IN 1

    IN 2

    GAID

    Made in USA

    SIEMENS

    SIEMENSMade in USA

    MS

    MODEL 4000

    OTION

    ENSOR

    Dual Single TrackSystem

    ROW B

    SIDE A

    TIMER

    MIN/SEC

    CLR

    MAIN

    AUTO

    STBY

    A80406

    Module

    TRANSFER

    HEALTH

    POWER

    GAID

    !

    NOTES:

    AVAILABLE WHEN PRIOR PARAMETER SELECTED

    DEFAULT SETTING

    SET BY FIELD AS REQUIRED

    IMPACTS OCCN

    MENUS OF PREVIOUS STEP.

    PARAEMTERS. ALPHA NUMERIC STEPS ARE SUB

    TERMINAL (DT) VER. 5.7.3 TO SET PROGRAM

    STEP SEQUENCE WHEN USING DIAGNOSTIC

    1.

    2.

    3.

    4.

    5.

    MS 4000 GCP

    10.0 KHZ

    077.30

    142 594T

    UAX

    5 SEC

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    06

    DATE:

    FILE:

    SHEET

    CL07730.06

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

    MT. PLEASANT RD.

    68E3BC9C

  • CONNECTORS FOR TRACK MODULEB

    D19

    BD22

    BD20

    BD16

    UNLESS NOTED OTHERWISE.

    ALL WIRING TO BE #16AWG

    NOTES:

    = TWIST

    = 1 INCH TEST LINK

    AC46

    AC46

    AD46

    AD46

    = TEST NUT

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    07

    DATE:

    FILE:

    SHEET

    CL07730.07

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

    R1

    R2

    T1

    T2

    B12

    N12

    #10

    #10

    #10

    #10

    #14

    #14

    #14

    #14

    G

    A

    I

    D

    ECH1

    ECH2

    B

    B

    N

    N

    CALLMAINT

    CPU II+

    +

    -

    +

    -

    +

    -

    +

    -

    IN1.1

    IN1.2

    TRKRCV1

    RCV2

    TRKCHK1

    CHK2

    TRKXMT1

    XMT2

    TRACK 1

    XR

    ISL

    C1

    C2

    #14

    #14

    B12

    N12

    NXC

    UG-4

    UG-4

    UG-5

    UG-5

    RC

    V-1

    RC

    V-2

    XM

    T-1

    XM

    T-2

    E E

    2AAC LINE

    15ADC BATT

    t-Rx7100

    GENESIS

    P/N 08033-2000

    RAIL SHUNT AUGMENTER

    BX110

    CX110

    AUXAC

    AUXRET

    B12

    N12

    SYSCHK+

    SYSCHK-

    T1A

    T1B

    T2A

    T2B

    SYSCHK+

    SYSCHK-

    T1-B

    T2-B

    NX120

    AVAILABLEHI/LO AC LINE

    AVAILABLE

    AVAILABLEHI/LO AC LINE

    IN USE

    SYSCHK FAULT

    SHEET

    NEXT

    TO

    #10

    #10

    N12

    B12

    AA28

    T

    AA28

    T

    AA30

    T

    AA30

    T

    AA28B

    AA30B

    T1-A

    T2-A

    #10

    #10

    ROW BSIDE A

    XC

    AC44

    AD44

    BX120-A11

    SHEET 4

    TO

    THIS SHEET

    CONT'D

    SYSCHK+

    SYSCHK-THIS SHEET

    CONT'D

  • CROSSING CONTROLLER HOOK-UP

    WARNING

    CAUTION

    SEVERE DAMAGE WILL OCCUR.ASSURE CORRECT POLARITY OR

    VEHICULAR TRAFFIC AND EMPLOYEES.TAKE ALTERNATE MEANS TO WARNMAY NOT OPERATE AS INTENDED.REMOVED, SIGNALS AND/OR GATES

    IF B OR N ARE FULLY OR PARTIALLY

    WARNING

    CONNECTOR J2DIRECTLY TO N ON

    DO NOT JUMPER 1GC

    1 2 3 4 5 6 7 8

    1GC 1 BELL

    OUTPUT A

    1 2 3 4 5 6 7 8

    2GC 2 BELL

    OUTPUT B

    1 2 3 4 5 6 7 8

    B N

    R

    SSCC IIIA40 AMP CROSSING CONTROLLER

    1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12

    LAN

    - + - + - + - + - + - + - + - +

    1 2 3 4 5 6 7 GP

    CROSSING CONTROL INPUTS

    J5

    DIAGNOSTIC

    J1

    J2

    J4J6

    CROSSING CONTROL STATUS

    1

    POWER

    2 3 4 5 6 7 HEALTH

    GP

    LAN

    1L1 1L2

    2L1 2L2

    Safetran A91160

    systems Made in USA

    Isolated Gate

    WARNING

    CONNECTOR J2DIRECTLY TO N ON

    DO NOT JUMPER 2GC

    RX

    TX

    I/O1 OUT2

    NON-VITAL

    SYNCH)

    (FLASH

    CALL)

    (MAINT

    NEXT

    S1

    PREVIOUS

    ENTER

    S2

    EXIT

    J4 J3J6

    CROSSING CONTROLLER IIIA

    40 AMP A91160

    NX

    C1 #16

    XC1 #16

    BC8 BC10T T

    N12

    #16

    #16

    5

    SHEET

    TO

    #16

    SHEET

    PREVIOUS

    TO

    #16

    NX

    C

    XC

    A

    UNLESS NOTED OTHERWISE.

    ALL WIRING TO BE #10AWG

    NOTES:

    BC4

    = 1 INCH TEST LINK

    * = UNDO TEST NUT TO FORCE CROSSING ACTIVATION

    *

    AD47

    = TEST NUT

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    08

    DATE:

    FILE:

    SHEET

    CL07730.08

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

    1G

    C

    1L1

    1L2

    B16

    B16

    N16

    N16

    N1G

    C1B

    EL

    L

    NEXT SHEET

    TO

    NG

    P #16

    SHEET

    NEXT

    TO

    GP #16

    B16

    N16

    XC

    1GC DELAY:

    2GC DELAY:

    SUBMENU

    PROGRAM

    NUMBERMCF PART

    MCF NAME MCF CRC

    9V610-A001F BASIC.MCF 1D240612

    GATES USED:

    NOTES

    FLASH RATE:

    SETTINGS

    GATE RISING BELL:

    MIN ACTIVATE TMR:

    ENABLED OUTPUTS:

    ENABLED INPUTS:

    TIME:

    DATE:

    DAYLIGHT SAVING:

    PASSWORD:

    30-70 FLASH/MIN DEF.=50

    YES/NO DEF.=YES

    3-20 SEC. DEF.=4

    3-20 SEC. DEF.=4

    ON/OFF DEF.=ON

    0-60 SEC. DEF.=0

    1 THRU 1 TO 7 DEF.=1 THRU 7

    A AND B, A, B DEF.=A AND B

    24 HOUR FORMAT

    YYYY MMM DD

    ENABLED/DISABLED DEF.=DISABLED

    ENABLED/DISABLED DEF.=DISABLED

    4 SEC.

    0 SEC.

    20 SEC.

    1 THRU 1

    A

    DISABLED

    50

    YES

    OFF

    ENABLED

    SUBMENU NOTES

    LOS TIMERS:

    SETTINGS

    CONFIGURE

    DEF.=0INPUTS 1-70-20 SEC. INPUT 1: 0

    INPUT 2: 0

    INPUT 3: 0

    INPUT 4: 0

    INPUT 5: 0

    INPUT 6: 0

    INPUT 7: 0

    ATCS ADDRESS:

    LOW BATTERY:

    AUX I/O:

    NEUTRAL WIRE:DETECT LAMP

    DEF.=700000000000 700000000000

    YES/NO DEF.=YES NO

    DEF.=DISABLED9.0-15.0 VOLTS OR DISABLED

    DEF.=NONVITAL OUTPUTFLASH SYNC OUT

    NONVITAL OUTPUT, FLASH SYNC IN, OUTPUT

    NONVITAL

    9.0 VOLTS

    SUBMENU PARAMETERS

    SETUP LAMP VOLTAGES

    OUTPUT 1 L1

    OUTPUT 1 L2

    OUTPUT 2 L1

    OUTPUT 2 L2

    XX.X VOLTS

    XX.X VOLTS

    N/A

    N/A

    SETTINGS FOR AS BUILT REVISION.

    CONSTRUCTION TO MARK VOLTAGE

  • PREVIOUS SHEET

    TO

    GND #6

    LIGHTING/SURGE PANEL HOOK-UP

    IN

    CR

    EA

    SE

    NE

    AR

    GA

    TE 1 L1 A

    DJ.

    0-.6\

    IN

    CR

    EA

    SE

    NE

    AR

    GA

    TE 1 L2

    ADJ.

    0-.6\

    B-1 B-2BATT

    B-BATT

    N-EQPT

    N-

    EQPTB-

    N-1 N-2

    1 GCBELL

    1 GP

    1L1 1L2

    1 L2

    NE

    AR

    1 L1 N

    EA

    R

    EN

    NE

    AR

    EN

    FA

    R

    1 L2 F

    AR

    1 L1 F

    AR

    GP1-

    AG

    P1-

    B

    GP

    1 B

    EL

    L-

    B

    1 B

    EL

    L-

    A

    1 G

    C-

    B

    1 G

    C-

    A

    N-

    B

    N-

    A

    B-

    B

    B-

    A

    A AB B

    E E E E E E E E

    E

    SHEET 5TO

    N16 #6

    B16 #6

    PANEL

    LIGHTING/SURGE

    91170-01

    B16

    B16

    SHEET

    PREVIOUS

    TO

    N16

    N16

    1B

    EL

    L

    1L1

    1L2

    NOTE:

    E = HEAVY DUTY EQUALIZER 022700-1X

    = HEAVY DUTY CLEARVIEW ARRESTER 022585-1X

    UNLESS NOTED OTHERWISE.

    ALL WIRING TO BE #10AWG

    BC49

    B16

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    09

    DATE:

    FILE:

    SHEET

    CL07730.09

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

    UG-1

    UG-1

    UG-1A

    UG-1A

    UG-1A

    UG-2

    UG-2

    UG-2

    A

    UG-2

    A

    UG-1A

    GP #16

    NG

    P #16

    AB16 #6

    BB16 #6

    AN16 #6

    BN16 #6

    AG

    C #14

    BG

    C #14

    AB

    EL

    L #14

    GP1 #14

    GP2 #14

    N1G

    C

    1G

    C

    UG-2

    A

    GP #14

    AE

    C #6

    AE

    Z #6

    AE

    B #6

    UG-1

    UG-1

    UG-1

    BE

    Z #6

    BE

    C #6

    BE

    B #6

    UG-2

    UG-2

    UG-2

    N16

    BB16 #14

  • AEB

    AEZ

    AEC

    WHITE

    GREEN

    2G 1G T

    "A" GATE ARM LIGHTS

    BLACK

    + -

    A BELL

    ABELL NABELL

    AN16

    AGC

    ABELL

    GP1

    2 1

    34

    4+

    2+

    2-

    4-

    3-

    1-

    1+

    3+

    FRONT

    BACK

    MASTLIGHTS

    FLASHING

    AEB1-3

    AEZ1-4

    AEC2-4

    GATE & FLASHER CIRCUITS SIGNAL "A"

    3C #14 GATE CABLE

    1A2A

    0°-86°

    7B7C

    4C 4B

    6B6C

    3B3C

    0°-10°

    82°-90°

    45°-90°

    LIMIT

    A1

    S2S1

    HOLD CLEAR

    MCR

    H

    BN

    SNUB

    A2

    P

    DEVICE

    LRU1

    LRU2

    SRU1

    SRU2

    MOTOR

    2A2C

    5B5C

    PS PF

    HSHF

    2C

    PWR. DWN.

    PD2

    PD1

    10°-90°

    W.C.H. MODEL 3593E

    BELL

    PWR. DN.

    G. CLEAR

    PWR UP

    1B1C

    6B 6A

    5A

    7A

    4A

    3A

    2B

    SNUB

    TE

    ST

    GATE A

    RESISTORHEATER

    THERMOSTAT

    BX110

    NX110

    GP

    NOTES: 1. GATE MECH. SHOWN IN CLEAR POSITION

    2. ALL WIRING TO BE #10AWG UNLESS OTHERWISE NOTED.

    3. = INTERNAL GATE WIRING

    = 1 INCH TEST LINK

    = INSULATED NUT = TEST NUT

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    10

    DATE:

    FILE:

    SHEET

    CL07730.10

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

    AGC

    NX110

    BX110

    AEB1-3

    AEZ1-4

    AEB

    AEZ

    TRACK SIDEJCT. BOXGATE "A"

    UG-1A TO HOUSE

    FIELD SIDEJCT. BOXGATE "A"

    UG-1 TO HOUSE

    AB16

    UG-17C#6

    UG-1A7C#14

    AGC

    ABELL

    GP1

    BX110

    NX110

    GP

    AB16

    AEB

    AEC

    AEZ

    AN16

    GP1

    GP

    ABELL

    AN16

    NABELL

    AEC2-4

    AECAB16

    JCT BOXGATE

  • 2 1

    34

    4+

    2+

    2-

    4-

    3-

    1-

    1+

    3+

    FRONT

    BACK

    MASTLIGHTS

    FLASHING

    BEB1-3

    BEZ1-4

    BEC2-4

    GATE & FLASHER CIRCUITS SIGNAL "B"

    NOTES: 1. GATE MECH. SHOWN IN CLEAR POSITION

    2. ALL WIRING TO BE #10AWG UNLESS OTHERWISE NOTED.

    3. = INTERNAL GATE WIRING

    = 1 INCH TEST LINK

    = INSULATED NUT = TEST NUT

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    11

    DATE:

    FILE:

    SHEET

    CL07730.11

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

    BEB

    BEZ

    BEC

    WHITE

    GREEN

    2G 1G T

    "B" GATE ARM LIGHTS

    BLACK

    BN16

    BGC

    GP2

    3C #14 GATE CABLE

    1A2A

    0°-86°

    7B7C

    4C 4B

    6B6C

    3B3C

    0°-10°

    82°-90°

    45°-90°

    LIMIT

    A1

    S2S1

    HOLD CLEAR

    MCR

    H

    BN

    SNUB

    A2

    P

    DEVICE

    LRU1

    LRU2

    SRU1

    SRU2

    MOTOR

    2A2C

    5B5C

    PS PF

    HSHF

    2C

    PWR. DWN.

    PD2

    PD1

    10°-90°

    W.C.H. MODEL 3593E

    BELL

    PWR. DN.

    G. CLEAR

    PWR UP

    1B1C

    6B 6A

    5A

    7A

    4A

    3A

    2B

    SNUB

    TE

    ST

    GATE B

    RESISTORHEATER

    THERMOSTAT

    BX110

    NX110

    BGC

    NX110

    BX110

    BEB1-3

    BEZ1-4

    BEB

    BEZ

    TRACK SIDEJCT. BOXGATE "B"

    UG-2A TO HOUSE

    FIELD SIDEJCT. BOXGATE "B"

    UG-2 TO HOUSE

    BB16

    UG-27C#6

    UG-2A7C#14BGC

    GP2

    BX110

    NX110

    BB16

    BEB

    BEC

    BEZ

    BN16

    GP2

    BN16

    BEC2-4

    BECBB16

    BB16 BB16

    BB16

    JCT BOXGATE

  • BA

    BB

    TERMINAL BOARD

    23

    45

    67

    89

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    26

    27

    28

    29

    30

    31

    32

    33

    34

    135

    OF

    TE

    RMIN

    AL

    BO

    AR

    D

    MO

    UN

    TE

    D

    ON

    BA

    CKSID

    E

    EM

    ER

    GE

    NC

    Y

    SWIT

    CH

    = 1 INCH TEST LINK

    UNDERGROUND CABLE TERMINATIONS.

    WIRES AND ON ALL LOW VOLTAGE

    INSTALL TEST LINKS ON ALL TRACK

    NOTE:

    = Heavy Duty Equalizer(022700-1X)

    E

    Lightning Arrester

    (022585-1X)

    Clearview

    =

    19

    20

    17

    18

    23

    24

    21

    22

    16

    14

    15

    13

    25

    35

    371

    34

    28

    29

    26

    27

    32

    33

    30

    31

    49

    50

    47

    48

    53

    54

    51

    52

    46

    40

    41

    38

    39

    44

    45

    42

    43

    55

    67

    68

    65

    66

    71

    36

    69

    70

    64

    58

    59

    56

    57

    62

    63

    60

    61

    RC

    V-2

    RC

    V-1

    XM

    T-2

    XM

    T-1

    E E

    BC

    BD

    = UNDO TEST NUT TO FORCE CROSSING ACTIVATION

    7'0

    " X 40"

    TE

    RMIN

    AL

    BO

    AR

    D

    = TEST NUT

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    12

    DATE:

    FILE:

    SHEET

    CL07730.12

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

    40

    A

    A91160

    SS

    CC IIIA

    10

    8

    1B

    EL

    L

    B16

    B16

    1L1

    1L2

    BE

    C

    BE

    B

    BE

    Z

    AE

    Z

    AE

    C

    AE

    B

    AB

    EL

    L

    91170-01

    PA

    NE

    L

    LIG

    HTIN

    G/

    SU

    RG

    E

    EE EE E EEE

    E

    NGP

    NXC1

    XC1

    B16

    B16

    1BELL

    1L1

    1L2

    B16

    B16

    B16

    N16

    N16

    N16

    = CLOSED DURING WINTER MONTHS

    = INSULATED NUT

    BX120-

    B

    NX120-

    B

    1GC

    N1GC

    GP

    N1G

    C

    NG

    P

    N16

    N16

    N16

    1G

    C

    GP

    GP1

    GP2

    GP

    BG

    C

    AG

    C

    BN16

    AN16

    BB16

    BB16

    AB16

    N16

  • 6' X 6' HOUSE - SIDE "A"

    0 FT. 1 FT. 2 FT. 3 FT.

    SIDE "A"

    2 4 6 8 10 12 14 16 18 20 22 2426 2830 32 3436 3840 42 4446 4850 52 5456 5860 626466

    AA

    AB

    AC

    AE

    12 52

    AD

    TK SYSTEM

    DUAL SINGLE

    MS 4000

    EQUIVALENT

    OR

    ELC-12/20-M-D

    B12 RECT.

    310 A.H.

    6 CELLS 50LF13-RR

    B12 BATT.

    12 14 52 54

    = 1 INCH TEST LINK

    NEMA RECEPTACLES ARE L5-30.

    NOTE:

    = TEST NUT

    E

    38

    T

    B

    B12 BUSS

    N12 BUSS

    44 49

    * = UNDO TEST NUT TO ACTIVATE XING

    T

    B

    T-RX7100

    GENESIS

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    13

    DATE:

    FILE:

    SHEET

    CL07730.13

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

    28 30

  • 6' X 6' HOUSE - SIDE "B"

    0 FT. 1 FT. 2 FT. 3 FT.

    SIDE "B"

    TERMINAL BOARD

    RELAY MOUNTING RACK

    TERMINAL BOARDTERMINAL BOARD

    OF TERMINAL BOARD

    MOUNTED ON BACKSIDE

    EMERGENCY SWITCH

    NORMAL EMERGENCY

    TERMINAL BOARD

    REAR VIEW

    8 4

    = INSULATED NUT

    NOTE:

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    14

    DATE:

    FILE:

    SHEET

    CL07730.14

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

  • 0 FT. 1 FT. 2 FT. 3 FT.

    6' X 6' HOUSE - SIDE "C"

    52 54

    EQUIVALENT

    OR

    ELC-12/40-M-D

    B16 RECT.

    SIDE "C"

    CA

    CB

    2 4 6 8 10 12 14 16 18 20 22 2426 2830 32 3436 3840 42 4446 4850 52 5456 5860 626466

    12 52

    CC

    CD

    CE12 14

    414 A.H.

    7 CELLS 50LF17-RR

    B16 BATT.

    = 1 INCH TEST LINK

    NEMA RECEPTACLES ARE L5-30.

    NOTE:

    = TEST NUT

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    15

    DATE:

    FILE:

    SHEET

    CL07730.15

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

  • 0 FT. 1 FT. 2 FT. 3 FT.

    SIDE "D"

    6' X 6' HOUSE - SIDE "D" & TOP VIEW

    DOOR

    PANEL

    BREAKER

    THERMOSTAT

    2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66

    TDFL

    120/240

    EPD

    #POKNOT TO SCALE(INSULATED)6'X6' HOUSE

    TOP VIEW*

    #=

    == SIDE D TO TO FACE STAIRS

    FIELD TO VERIFY PLACEMENT OF POK.REMOVE LIGHT NOT NEEDED.

    ABOVE FLOOR

    MOUNTED 18"

    #POK

    CSC151TW

    CADET

    120V,1500W

    HEATER

    WALL

    CLEVELAND LINE

    DESIGNED BY:

    DIGITIZED BY:

    CHECKED BY:

    16

    DATE:

    FILE:

    SHEET

    CL07730.16

    03/20/19

    01REV

    STRASBURG, OH

    MGH

    RJC

    RWM

    RJ Corman RailroadNICHOLASVILLE, KY 40356

    P.O. BOX 788 101 RJ CORMAN DR

    M.P. 077.30 D.O.T. 142-594T

    MT. PLEASANT RD.

    TE

    RMIN

    AL

    BO

    AR

    D

    BR

    EA

    KE

    RB

    OX

    SID

    E

    D

    SIDE C

    6'X6' HOUSE LAYOUT

    SIDE A

    SID

    E

    B

    LIG

    HT

    S

    EP

    D