600a, 15 kv class elbow tap plug (etp) load reducing tap ... · the etp is also ideal for adding a...

4
www.chardongroup.com 600A, 15 kV Class Elbow Tap Plug (ETP) Load Reducing Tap Plug (LRTP) 25-ETP600-15-200 25-LRTP600-15-200

Upload: others

Post on 20-Jul-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 600A, 15 kV Class Elbow Tap Plug (ETP) Load Reducing Tap ... · The ETP is also ideal for adding a 200A tap to an existing 600A T-Body connector. The 200A interface allows for live

www.chardongroup.com • [email protected] www.chardongroup.com

No.37 Min-Chie Road, Tung LoIndustrial Park, Miao Li, Taiwan 366T e l : + 8 8 6 - 3 7 - 9 8 4 3 8 5F a x : + 8 8 6 - 3 7 - 9 8 4 7 7 0

600A, 15 kV ClassElbow Tap Plug (ETP)Load Reducing Tap Plug (LRTP)

25-ETP600-15-20025-LRTP600-15-200

Page 2: 600A, 15 kV Class Elbow Tap Plug (ETP) Load Reducing Tap ... · The ETP is also ideal for adding a 200A tap to an existing 600A T-Body connector. The 200A interface allows for live

APPLICATION VOLTAGE RATINGS

PRODUCTION TESTS

Tests conducted in accordance with IEEE/ANSI Standard 386.Minimum Corona Voltage Level – 11 kVAC 1 Minute Withstand – 34 kV

Tests conducted in accordance with Chardon manufacturing process requirements:Physical InspectionPeriodic DissectionPeriodic X-ray Analysis

• 25ETP/LRTP-15-200-021819-REV01

Voltage Class 15 kV

Max. Rating Phase to Phase 14.4 kV

Max. Rating Phase to Ground 8.3 kV

AC 1 Minute Withstand 34 kV

DC 15 Minute Withstand 53 kV

BIL and Full Wave Crest 95 kV

Minimum Corona Voltage Level 11 kV

and visible ground. In addition, it can be used to add a 200A tap, or for the installation of an elbow arrester. The LRTP has a factory installed alignment guide with a shear pin that allows the alignment guide to disengage after installation. When the LRTP is screwed into the threaded insert of a bushing extender or threaded 600/900A compression connector, the alignment guide disengages once the proper amount of torque is applied.

B o t h t h e E T P a n d L R T P m e e t a l l t h e requirements of IEEE Standard 386, and are 200A three phase switching and three phase fault close rated.

The Chardon ETP and LRTP incorporate an all copper current path. This provides reliable and consistent performance under all conditions.

The Chardon Elbow Tap Plug (ETP) and Load Reducing Tap Plug (LRTP) are used to convert a standard 600A deadbreak inter face to a standard 200A loadbreak interface.

The ETP is ideal for applications where a 200A tap is desired for test or ground purposes. The ETP is also ideal for adding a 200A tap to an existing 600A T-Body connector. The 200A interface allows for live test, visible ground, addition of a 200A tap, or installation of an elbow arrester.

The LRTP is ideal for applications where the termination will be separated to achieve a visible break and ground. Having the T-body and LRTP connected, as one unit, makes it easier to install and remove from the mating bushing interface. The 200A interface allows for live test, phasing,

Description Amperes

600A InterfaceContinuous 600 amps rms

Short Time • 25,000 amps rms symmetrical for 0.17 s• 10,000 amps rms symmetrical for 3.0 s

200A Interface

Continuous 200 amps rms

Switching 10 operations at 200 amps rms at 14.4 kV

Fault Close 10,000 amps rms symmetrical at 14.4 kV for 0.17 s after 10 consecutive successful switching operations

Short Time • 10,000 amps rms symmetrical for 0.17 s• 3,500 amps rms symmetrical for 3.0 s

CURRENT RATINGS

*Note: System design and protection must recognize the ratings of 200A interface.

w w w . c h a r d o n g r o u p . c o m

Page 3: 600A, 15 kV Class Elbow Tap Plug (ETP) Load Reducing Tap ... · The ETP is also ideal for adding a 200A tap to an existing 600A T-Body connector. The 200A interface allows for live

DETAILED COMPOSITION OF THE CHARDON LOAD REDUCING TAP PLUG (LRTP)

DETAILED COMPOSITION OF THE CHARDON ELBOW TAP PLUG (ETP)

INSULATION LAYERHigh quality peroxide cured EPDM Insulation is mixed and formulated in-house for complete control of rubber characteristics.

INSULATION LAYERHigh quality peroxide cured EPDM Insulation is mixed and formulated in-house for complete control of rubber characteristics.

DRAIN WIRE TABDrain wire tabs provide a convenient point to connect drain wire to ensure grounding of the connector shield.

STOP RINGLimits piston and finger contact travel during fault close.

STOP RINGLimits piston and finger contact travel during fault close.

LOCKING GROOVELocking groove assures proper installation by “locking” into elbow.

LOCKING GROOVELocking groove assures proper installation by “locking” into elbow.

ARC SNUFFER ASSEMBLYArc quenching material extinguishes gas during loadbreak operations.

ARC SNUFFER ASSEMBLYArc quenching material extinguishes gas during loadbreak operations.

FINGER CONTACTTin plated copper contact provides a consistent current transfer during switching and fault close operations.

FINGER CONTACTTim plated copper contact provides a consistent current transfer during switching and fault close operations.

HEX BROACH5/16” hex broach permits installation with torque tool.

HEX BROACH5/16” hex broach permits installation with torque tool.

SEMICONDUCTING SHIELDPrecision molded peroxide cured semiconducting shield provides ground shie ld cont inuit y and meets the requirements of IEEE Standard 592.

SEMICONDUCTING SHIELDPrecision molded peroxide cured semiconducting shield provides ground shie ld cont inuit y and meets the requirements of IEEE Standard 592.

15 kV, 600A Elbow Tap Plug 25-ETP600-15-200 15 kV, 600A Load Reducing Tap Plug 25-LRTP600-15-200

ORDERING INFORMATION ORDERING INFORMATION

THREADED CONNECTIONTO T-BODY5/8” – 11 UNC copper threads provided connection to T-Body connector.

THREADED CONNECTION TO T-BODY15/16” – 9 NS 2A stationary threads mate with 600A compression connector or bushing extender.

THREADED CONNECTION TO T-BODY5/8” – 11 UNC threads provided connection to T-Body connector.

200A INTERFACE200A INTERFACE

600A INTERFACE

600A INTERFACE

8.30" (210.8mm

)

8.30" (210.8mm

)1.90"

(48.2mm

)

w w w . c h a r d o n g r o u p . c o m

Page 4: 600A, 15 kV Class Elbow Tap Plug (ETP) Load Reducing Tap ... · The ETP is also ideal for adding a 200A tap to an existing 600A T-Body connector. The 200A interface allows for live

www.chardongroup.com • [email protected] www.chardongroup.com

No.37 Min-Chie Road, Tung LoIndustrial Park, Miao Li, Taiwan 366T e l : + 8 8 6 - 3 7 - 9 8 4 3 8 5F a x : + 8 8 6 - 3 7 - 9 8 4 7 7 0