6/10 kv xlpe İzolelİ ve alÜmİnyum İletkenlİ tek damarli kablolar · 2016. 11. 10. · tek...

1
(VDE Code: NA2XSY) 1 2 40 3 8 7 6 5 4 mm 2 mm kg/km m ohm/km A cm 1x 50/16 1x 70/16 1x 95/16 1x120/16 1x150/25 1x185/25 1x240/25 1x300/25 1x400/35 1x500/35 1x630/35 25.0 26.0 28.0 29.0 31.0 33.0 35.0 38.0 41.0 45.0 50.0 700 810 910 1020 1220 1360 1580 1840 2260 2650 3200 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 141 141 161 161 161 161 181 201 221 221 261 215 269 327 377 424 485 573 652 741 838 957 A mH/km mH/km A A μF/km 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 0.0605 0.0469 0.73 0.69 0.66 0.64 0.62 0.61 0.58 0.56 0.55 0.53 0.51 0.41 0.38 0.36 0.35 0.34 0.33 0.32 0.31 0.30 0.29 0.28 0.24 0.27 0.30 0.33 0.36 0.39 0.44 0.48 0.53 0.59 0.68 194 236 281 318 350 393 453 507 559 622 697 171 209 249 283 316 358 416 469 532 599 679 181 226 275 317 359 412 489 559 651 744 851 6/10 kV XLPE İZOLELİ VE ALÜMİNYUM İLETKENLİ TEK DAMARLI KABLOLAR Orta Gerilim Kablolar IEC 60502-2 standardına göre Yapı: 1-Alüminyum iletken 2-İç yarı iletken tabaka 3-XLPE izole 4-Dış yarı iletken tabaka 5-Yarı iletken bant 6-Bakır ekran 7-Koruma bantı 8-PVC dış kılıf Kullanıldığı yerler: Ağır işletme koşullarında, yer altında, kablo kanallarında güç ve anahtarlama merkezlerinde, şehir şebekelerinde ve endüstri tesislerinde İzin verilen işletme sıcaklığı 90°C İzin verilen kısa devre sıcaklığı 250°C (5 s süre için) Nominal kesit Standart sevk uzunluğu Sevk makarası tipi Dış Çap (yakl.) Net ağırlık (yakl.) İletken başına endüktans (yakl.) İşletme kapasitesi (yakl.) BOYUT VE AĞIRLIKLAR ELEKTRİKSEL ÖZELLİKLER Akım taşıma kapasitesi * Toprakta Havada İletken dc direnci 20°C’da (max.) * Lütfen açıklayıcı notlara bakınız.

Upload: others

Post on 08-Oct-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 6/10 kV XLPE İZOLELİ VE ALÜMİNYUM İLETKENLİ TEK DAMARLI KABLOLAR · 2016. 11. 10. · TEK DAMARLI KABLOLAR Orta Gerilim Kablolar IEC 60502-2 standardına göre Yapı: 1-Alüminyum

(VDE Code: NA2XSY)

1

2

40

3

8

7

6

5

4

mm2 mm kg/km m ohm/km Acm

1x 50/16

1x 70/16

1x 95/16

1x120/16

1x150/25

1x185/25

1x240/25

1x300/25

1x400/35

1x500/35

1x630/35

25.0

26.0

28.0

29.0

31.0

33.0

35.0

38.0

41.0

45.0

50.0

700

810

910

1020

1220

1360

1580

1840

2260

2650

3200

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

141

141

161

161

161

161

181

201

221

221

261

215

269

327

377

424

485

573

652

741

838

957

AmH/km mH/km AAµF/km

0.641

0.443

0.320

0.253

0.206

0.164

0.125

0.100

0.0778

0.0605

0.0469

0.73

0.69

0.66

0.64

0.62

0.61

0.58

0.56

0.55

0.53

0.51

0.41

0.38

0.36

0.35

0.34

0.33

0.32

0.31

0.30

0.29

0.28

0.24

0.27

0.30

0.33

0.36

0.39

0.44

0.48

0.53

0.59

0.68

194

236

281

318

350

393

453

507

559

622

697

171

209

249

283

316

358

416

469

532

599

679

181

226

275

317

359

412

489

559

651

744

851

6/10 kV XLPE İZOLELİ VE ALÜMİNYUM İLETKENLİTEK DAMARLI KABLOLAR

Orta Gerilim Kablolar

IEC 60502-2 standardına göre

Yapı:

1-Alüminyum iletken2-İç yarı iletken tabaka3-XLPE izole4-Dış yarı iletken tabaka5-Yarı iletken bant6-Bakır ekran7-Koruma bantı8-PVC dış kılıf

Kullanıldığı yerler:

Ağır işletme koşullarında, yer altında, kablo kanallarındagüç ve anahtarlama merkezlerinde, şehir şebekelerindeve endüstri tesislerinde

İzin verilen işletme sıcaklığı 90°Cİzin verilen kısa devre sıcaklığı 250°C(5 s süre için)

Nominalkesit

Standartsevk

uzunluğu

Sevkmakarası

tipi

Dış Çap(yakl.)

Netağırlık

(yakl.)

İletkenbaşına

endüktans(yakl.)

İşletmekapasitesi

(yakl.)

BOYUT VE AĞIRLIKLAR ELEKTRİKSEL ÖZELLİKLER

Akım taşımakapasitesi*

Toprakta Havada

İletkendc

direnci20°C’da(max.)

* Lütfen açıklayıcı notlara bakınız.