61.sdh alarm & pm
TRANSCRIPT
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 1/25
1
ALARM AND PERFORMANCE
MONITORING
SDH
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 2/25
2
Overhead Termination
LPT HPT MST RST RST MST HPT LPTRSOH
MSOH
VC-4 POH
VC-12, VC-3 POH
2M, 34M Unit STM-n Unit 2M, 34M Unit
LPT: Lower-order Path termination
HPT: High-order Path termination
MST: Multiplex Section Termination
RST: Regenerator Section Termination
STM-n Unit
STM-n Unit or
140M Unit
STM-n Unit or
140M Unit
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 3/25
3
Overhead Termination
STM-N unit
STM-N
TSI unit
RST MST HPT LPT
Crossconnect
Level
VC-12 or VC-32M or 34M
2M or 34M unit
STM-N unit
STM-N
TSI unit
RST MST HPT
Crossconnect
Level
VC-4140M
140M unit
STM-N unit
STM-N
TSI unit
RST MST HPT HPT MST RST
Crossconnect
Level
VC-12 or VC-3STM-N
STM-N unit
STM-N unit
STM-N
TSI unit
RST MST RST
Crossconnect
Level
VC-4STM-N
STM-N unit
MST
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 4/25
4
Performance Monitoring Point
Physical Layer
Section Layer
Adaptation
High/Low-order Path Termination
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 5/25
5
Optical Interface
LDBC : Laser Diode Bias Current
PDH Interface
CV-L : Code Rule ViolationES-L : Errored Second
SES-L : Severely Errored Second
External Clock Interface
CV- : Code Rule Violation
ES- : Errored Second)
SES- : Severely Errored Second
: L or P
Performance Monitoring-Physical Layer-
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 6/25
6
Regenerator (RS) and Multiplex (MS) SectionES- : Errored Second
SES- : Severely Errored Seconds
BBE- : Background Block Error
UAS- : Unavailable Seconds
OFS-
: Out of Frame Seconds (OOF) Multiplex Section Far-end
ES-MSFE : Errored Second
SES-MSFE : Severely Errored Seconds
BBE-MSFE : Background Block Error
UAS-MSFE : Unavailable Seconds
Multiplex Section
PSC : Protection Switching Count
PSD : Protection Switching Duration
Performance Monitoring-Section Layer-
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 7/25
7
AU-4 Pointer
PJE (positive) : Pointer Justification Event (positive)
PJE (negative) : Pointer Justification Event (negative)
Performance Monitoring-Adaptation-
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 8/25
8
High/Low-order Path (receiving direction)
ES- : Errored Second
SES- : Severely Errored Seconds
BBE-
: Background Block Error UAS- : Unavailable Seconds
High/Low-order Path (transmitting direction)
ES-FE : Errored Second
SES-FE : Severely Errored Seconds
BBE-FE : Background Block Error
UAS-FE : Unavailable Seconds
: HO or LO
Performance Monitoring-Path Termination-
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 9/25
9
Terms and Definitions(used by error performance)
EDC : Error Detection Code
Block : block
EB : Errored Block
Defect : defect
ES : Errored Second
SES : Severely Errored Second
BBE : Background Block Error CV : Code Violation
UAS : Unavailable Second
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 10/25
10
1
2
2348
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
5
5
5
5
6
6
6
6
7
7
7
7
8
8
8
82349
31
262
2
263
2348 2349
Gro up o f 8 bits
VC-4
261
B l o c k ( 1 8 7 9 2 b i t s / b l o c k )
BIP-8 of VC-4
B3
BIP-8 check sequence
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 11/25
11
Terms and Definitions(used by error performance)
EDC : Error Detection Code
Block : block
EB : Errored Block
Defect : defect
ES : Errored Second
SES : Severely Errored Second
BBE : Background Block Error CV : Code Violation
UAS : Unavailable Second
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 12/25
12
Terms and Definitions(used by error performance)
EDC : Error Detection Code
Block : block
EB : Errored Block
Defect : defect
ES : Errored Second
SES : Severely Errored Second
BBE : Background Block Error CV : Code Violation
UAS : Unavailable Second
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 13/25
13
Relation between ES, SES and BBE
B
l o
c
k
s
i n
1
s
e
c
.
p
e
r i
o
d
3 0 %
1 s e c .
E SS E S
EB} B B Enon E B
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 14/25
14
Terms and Definitions(used by error performance)
EDC : Error Detection Code
Block : block
EB : Errored Block
Defect : defect
ES : Errored Second
SES : Severely Errored Second
BBE : Background Block Error CV : Code Violation
UAS : Unavailable Second
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 15/25
15
10 sec. 10 sec.< 10 sec.
Unavailability detected Availability detected
Unavailable period Available period
Error-fr ee second Sever ely e
rror ed sec
ondSES
Error ed sec
ond
ES
Unavailable Second
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 16/25
16
1 day
(Yester day)
Curr ent 1 day (Today)
data update : ever y 1 min.
0 : 00 0 : 00
TCA (Thr eshold Crossing Aler t)
1 day accumulation
32 per iods with zero suppr ession(32) (2) (1)
15 min.
hh : 15n hh : 15(n+1)Curr ent 15 min.
data update : ever y 1 min.
15 minute accumulation
TCA (Thr eshold Crossing Aler t)
Storage of PM data
timepast f utur e
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
item a
item b
item x
item y
item a
item b
item x
item y
memor yold new
Zero Suppression
all zero data with time stamp of occurrence
Zero Suppression
PM items of one f acility
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 17/25
17
Error Detection Point
LO Path
HO Path
MS
RS
RST
B2
MSTMST
B1
RST HPTHPT
BIP-8
BIP-24N
REI
REI
M1
G1
STM-16
STM-4
STM-1o
STM-1e
STM-16
STM-4
STM-1o
STM-1e
STM-16
STM-4
STM-1o
STM-16
STM-4
STM-1o
REI
B3
CMI
CV
2M/34M 2M/34M
BIP-2V5
V5
BIP-8
HDB3
BPV
LPT LPT
Generate
Terminate
140M or
STM-N
140M or
STM-N
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 18/25
18
Office Alarms
Miscellaneous Alarms and Controls
LCT and NMS
Housekeeping Alarms and Controls
Alarms and Remote Controls
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 19/25
19
Alarms Output Control
Output Function
Prompt Maintenance (PM) alarm Indicates prompt maintenance alarm initiated inthe local or remote NE.
Deferred Maintenance (DM) alarm Indicates deferred maintenance alarm initiated inthe local or remote NE.
Remote (RMT) alarm Indicates an alarm is initiated in the remote NE.User can select whether he contains it or not into alighting condition of DM lamp with a switch of lamp section.
Maintenance (MAINT) status Indicates the local or remote NE is inmaintenance status.
Alarm signal for bell (AB) Indicates the local NE is in alarm by astation alarm bell.
Alarm signal for lamp (AL) Indicates the local NE is in alarm by astation alarm.
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 20/25
20
Alarm States and Severity
CR - Critical
MJ - Major
MN - Minor
WA - Warning
RMT - Remote
IN - Indeterminate
NA - No Alarm (report status)
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 21/25
21
Remote Alarms-1
MUXStation A
REG
Station 1REG
Station 2
MUXStation B
MUXStation C
REG 1 REG 2
REG 1
REG 2
REG 1
REG 2
REG 1
REG 2
: Alar m occurr ance station
: Remote alar m detection station
: Station in which the alar m gener ated in REG 1 is detected as a r emote alar m
: Station in which the alar m gener ated in REG 2 is detected as a r emote alar m
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 22/25
22
Remote Alarm-2
ALM1 MJ
ALM2 MJ
ALM3 MJ
ALM4 MJ
ALM5 MN
FE_ MJ
MUX Station A MUX Station B
FE_ MN
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 23/25
23
NMS Network Structure
Bridge
LCT
INC
-100
Bridge
DCCr DCCr DCCr
DCCr
DCCr
DCCr
D C C r
L A
N
L A
N
Data channel ( D4~12 or other )
Area 1 Area 2
L A
N
AGENT
SC
AGENT
SC
AGENT
SC
AGENT
SC
AGENT
SC
AGENT
SC
AGENT
SC
AGENT
SC
AGENT
SC
AGENT
SC
AGENT
SC
AGENTSC
AGENT
SC
AGENT
SC
AGENT
SC
5/12/2018 61.Sdh Alarm & Pm - slidepdf.com
http://slidepdf.com/reader/full/61sdh-alarm-pm 24/25
24
Remote Access by LCT