64283 darmstadt component-id 1230wi03 valid until 31st ... · 64283 darmstadt component-id 1230wi03...
TRANSCRIPT
CERTIFICATECertified Passive House Component
Passive House InstituteDr. Wolfgang Feist64283 Darmstadt
GermanyComponent-ID 1230wi03 valid until 31st December 2021
www.passivehouse.com
Category: Window FrameManufacturer: Hebei Orient Sundar Window Co.,
Ltd.,Gaobeidian City, Hebei Province,China
Product name: Passive 130
This certificate was awarded based on the followingcriteria for the cool, temperate climate zone
Comfort UW = 0.80 ≤ 0.80 W/(m2 K)UW ,installed ≤ 0.85 W/(m2 K)with Ug = 0.70 W/(m2 K)
Hygiene fRsi=0.25 ≥ 0.70
CERTIFIEDCOMPONENTPassive House Institute
cool, temperate climate
phBPassive House
efficiency class phE phD phC phB phA
Hebei Orient Sundar Window Co., Ltd.Internation Window-Door Science-Technology Buiding, Dongfang Road No.7, 074000 GaobeidianCity, Hebei Province, ChinaT + 863126392755 |B [email protected] | Í http://www.alrunsd.com |
20 o
C
18 o
C
16 o
C
14 o
C
12 o
C
10 o
C
8 o
C
6 o
C
4 o
C
2 o
C
0 o
C
-2 o
C
-4 o
C
-6 o
C
-8 o
C
-10 o
C
Calculation model Isothermal
Description
Timber - PVC profile with aluminium facing shell. XPS insulation (0.032) infront of the blindframe.Pane thickness: 48 mm (4/18/4/18/4), Rebate depth: 17 mm.
Explanation
The window U-values were calculated for the test window size of 1.23 m× 1.48 m with Ug = 0.70 W/(m2 K).If a higher quality glazing is used, the window U-values will improve as follows:
Glazing Ug = 0.70 0.64 0.58 0.54 W/(m2 K)↓ ↓ ↓ ↓
Window UW = 0.80 0.76 0.72 0.69 W/(m2 K)
Transparent building components are classified into efficiency classes depending on the heat lossesthrough the opaque part. The frame U-Values, frame widths, thermal bridges at the glazing edge, andthe glazing edge lengths are included in these heat losses. A more detailed report of the calculationsperformed in the context of certification is available from the manufacturer.
The Passive House Institute has defined international component criteria for seven climate zones. Inprinciple, components which have been certified for climate zones with higher requirements may alsobe used in climates with less stringent requirements. In a particular climate zone it may make senseto use a component of a higher thermal quality which has been certified for a climate zone with morestringent requirements.
Further information relating to certificationcan be found on www.passivehouse.com and passipedia.org.
2/4 Passive 130
www.passivehouse.com
Frame width U-value frame Ψ -panel edge Temp. Factorbf Uf Ψg fRsi=0.25
Framevalues mm W/(m2 K) W/(m K) [-]
Top (to) 130 0.74 0.034 0.71
Side (s) 130 0.74 0.034 0.71
Bottom (bo) 130 0.74 0.034 0.71
Mullion2 casements
(m2) 201 0.78 0.033 0.71
Spacer: Thermix TX.N plus Secondary seal: Polysulfid
Validated installations
Formwork blocks (operable)
UWall = 0.13 W/(m2 K)
Ψinstall W/(m K)Top 0.009Side 0.009Bottom 0.013
UW ,installed = 0.83 W/(m2 K)
Exterior insulation and finishingsystem
UWall = 0.13 W/(m2 K)
Ψinstall W/(m K)Top 0.008Side 0.008Bottom 0.013
UW ,installed = 0.82 W/(m2 K)
Lightweight timber (operable)
UWall = 0.14 W/(m2 K)
Ψinstall W/(m K)Top 0.019Side 0.019Bottom 0.023
UW ,installed = 0.86 W/(m2 K)
3/4Component-ID: 1230wi03
www.passivehouse.com
www.passivehouse.com