7/25/12 www.CodeDataPlate.com 1 VIR G INIA ELEVATO R SAFETY ASSO C IA TIO N A 17 C ode R equired D ata Plates, Tagsand Signs w hat’snew and w hat’snotin A 17.1-2007, a-2008, b-2009 & in A17.1-2010 by:John S.R earick CodeDataPlate.com

Upload: rosa-irma-bailey

Post on 29-Jan-2016

329 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 1

VIRGINIA ELEVATOR SAFETY ASSOCIATION

A17 Code Required Data Plates, Tags and Signs

what’s new and what’s not in A17.1-2007, a-2008, b-2009 & in

A17.1-2010by: John S. Rearick

CodeDataPlate.com

Page 2: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 2

Disclaimer

The opinions and recommendations presented here are strictly my own and are not those of ASME, NAESAI, IAEC or any organization of which I may be a member.

JSRearick

Page 3: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

3

Who are we?• CodeDataPlate.com is the trade name of Rearick &

Company, Inc. – Elevator Consulting

• CodeDataPlate.com was formed 11 years ago to provide accurate on-site code information to inspectors when performing inspections.

• Started with just Code Data Plates (still 50% of our business)

• Grown to include – Crosshead Data Plates

– Inspection Tags

– Other code specific Data Plates, Tags & Signs

– Maintenance Control Program assistance & formatting

• Primary customer: Elevator Contractors

Page 4: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

4

ASME A17 Involvement (since 1995)• Existing Installations, Chair

– Section 8.7 - Alterations

– A17.3 Code for Existing Installations

– Ex-Officio – Standards Committee

• Maintenance, Repair & Replacement– Section 8.6

– MCP Task Group

• Inspections– Sections 8.10, 8.11 and Testing parts of 8.6

– A17.2 Guide for Inspectors

• Wind Tower Elevator Committee• Inclined Elevator Committee• Ad Hoc Data Plate

Page 5: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

5

Code Making Process• Inquiry

– Format: Edition and Requirement Number– Assigned to Working Committee to answer– Technical Revision (TN) Developed if needed

• Review and approved by Standards Comm.

• Interpretation published

• Approved TN’s go into Public Review Draft

• Finally are published in next Code Edition

Page 6: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 6

Changes affecting Code Data Plates

in Sections 8.7 and 8.9

A17.1-2007 EditionAddenda a-2008 & b-2009

A17.1-2010 Edition

Page 7: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 7

8.7 Summary of changes in 2007 Edition

8.7.1.7 Second sentence added8.7.1.8 Second sentence added8.7.2.1.3 Editorially revised8.7.2.1.4 Editorially revised8.7.2.7.6 Editorially revised8.7.2.7.7 Editorially revised8.7.2.15.2 Revised in its entirety8.7.2.17 Title editorially revised8.7.2.17.1 Title and paragraphs editorially revised8.7.2.17.2(b)(5) Editorially revised8.7.2.23 Revised in its entirety8.7.2.25.1(a) Editorially revised8.7.2.25.2(a) Editorially revised8.7.2.25.2(b) Editorially revised8.7.2.27.6 First paragraph revised8.7.2.27.8 Added

Page 8: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 8

8.7 and 8.9 Summary of changes in 2007 Edition

8.7.3.15.3 Editorially revised8.7.3.19 Editorially revised8.7.3.22 Title editorially revised8.7.3.22.1 First paragraph and subparagraphs

(b), (c), and (e) editorially revised8.7.3.23.1 Revised8.7.3.23.2 Revised8.7.3.23.3 Revised8.7.3.31.11 Added8.7.4.3.7 Title and paragraphs editorially revised8.7.6.1.1 Revised in its entirety8.7.6.1.5 Revised in its entirety8.7.6.1.9 Third paragraph deleted8.7.6.2.1 Revised8.9.2 Revisedand in 8.9

Page 9: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 9

8.7 Summary of changes in a-2008 Addenda

8.7.2.14.2(i) Added8.7.2.27.3 First paragraph revised8.7.2.27.4 (1) Subparagraph (a) revised (2) Subparagraph (c) added8.7.2.28 Revised in its entirety8.7.3.31.4 First paragraph revised8.7.3.31.5(a) Revised8.7.3.31.5(c) Added8.7.3.31.8(c) Revised8.7.5.3 Revised in its entirety8.7.5.4 Revised in its entirety

Page 10: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 10

8.7 and 8.9 Summary of changes in b-2009 Addenda

and in 8.9

Page 11: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 11

8.7 and 8.9 Summary of changes in 2010 Edition

8.7.2.1.1 (e) Access Door reference corrected 8.7.2.21 Title revised – Suspension Ropes to Means 8.7.2.21.1& .21.3 Ropes to Means 8.7.2.21.4 Added Monitoring & Protection 8.7.3.31.10 Editorially revised a reference 8.7.6.2.7 (a) Editorially revised references 8.7.6.2.9 Editorially revised a reference 8.7.6.2.12 (a) Editorially revised references 8.9.1 First and second sentences revised 8.9.2 First and last sentences revised 8.9.3 Revised added requirements

Page 12: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 12

8.7 Alterations

Page 13: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 13

Alteration Changes in A17.1-2007, a-08 & b-09 except control

• 8.7.1.7 Adds Canadian (NBCC) Exceptions

• 8.7.1.8 Adds Canadian (NBCC) Exceptions

• 8.7.2.1.3Editorial correction

• 8.7.2.1.4Editorial correction

• 8.7.2.7.1Now includes both machine & control spaces

• 8.7.2.7.6 Editorial correction

• 8.7.2.7.7 Editorial correction

• 8.7.2.10.1 Now includes 2.29.2 (4” number inside door)

• 8.7.2.14.2(i) Adds requirements for car door or gate

• 8.7.2.15.2 Revised Buffer requirements

• 8.7.2.17 Editorial correction

• 8.7.2.23 Revised Buffer requirements

• 8.7.2.25 Editorial correction

(a)(b)

(b)

Page 14: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 14

Alteration Changes in A17.1-2007, a-08 & b-09 except control

• 8.7.3.15.3 Editorial correction

• 8.7.3.19 Editorial correction

• 8.7.3.15 Editorial correction

• 8.7.3.19 Editorial correction

• 8.7.3.22 Editorial correction

• 8.7.3.23 Jacks are now stand alone alteration – see slide

• 8.7.4.3.7 Editorial correction (travel to rise in about 50 places)

• 8.7.5.3 Added Private Residence Requirements

• 8.7.5.4 Added Private Residence RequirementsReason: Many private residences have been converted to convention centers, banquet facilities, museums, etc.; where the elevators are used by the general public or as a Limited-Use/Limited-Application elevator. In these cases, the more stringent safety requirements of ASME A17.1 need to be applied.

• 8.7.6.1 Escalator alteration updated

• 8.7.6.2 Moving Walk alteration upgraded

(a)

(a)

Page 15: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 15

Alteration Changes in 2010 Edition

8.7.2.1.1 (e) Access Door reference corrected 8.7.2.21 Title revised – Suspension Ropes to Means 8.7.2.21.1& .21.3 Ropes to Means 8.7.2.21.4 Added Monitoring & Protection 8.7.3.31.10 Editorially revised a reference 8.7.6.2.7 (a) Editorially revised references 8.7.6.2.9 Editorially revised a reference 8.7.6.2.12 (a) Editorially revised references 8.9.1 First and second sentences revised 8.9.2 First and last sentences revised 8.9.3 Revised added requirements

Page 16: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 16

Note: These 3 requirements are often mixed up.

TN 03-1712

Revise A17.1 requirements 8.7.3.23.1, 8.7.3.23.2 and 8.7.3.23.3 as follows:

8.7.3.23.1 Hydraulic Jack. Where the alteration involves the installation of a hydraulic jack, it is installed,altered or replaced it shall conform to 3.18.

8.7.3.23.2 Plungers. Where a new plunger is installed as part of an alteration or an existing plunger isaltered, it shall conform to 3.18.1.2 and 3.18.2.

8.7.3.23.3 Cylinders. Where a cylinder is installed, replaced as part of an alteration, altered, or sleeved, itshall conform to 3.18.3. If the plunger is not equipped with a stop ring conforming to 3.18.4.1, theinstallation shall also conform to 3.18.1.2 and 3.18.2.

Reason:Requirement 8.6.3.10 identifies replacement of jacks, plungers, and cylinders as an alteration and referredto 8.7.3.23. This proposed change clarifies the need to comply with existing requirements even though thereplacement is not “part of an alteration”. (See new proposed definition in TN 02-3899 for “Alteration aspart of – A repair and/or replacement that is included with other work that is classified as an alteration”)

Page 17: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 17

Alteration Changes in A17.1-2007, a-08 & b-09 for control

• 8.7.2.27.8 and 8.7.3.31.11 Added

Electrical Protective Devices. Where there is an alteration to or addition of an electrical protective device, it shall conform to 2.26.2 for that device.

• 8.7.2.27.3 POWER

• 8.7.2.27.4 CONTROL REPLACEMENT

• 8.7.2.27.5 MOTION

• 8.7.2.27.6 OPERATION

• 8.7.3.31.4 POWER

• 8.7.3.31.5 CONTROL REPLACEMENT

• 8.7.3.31.6 MOTION

• 8.7.3.31.7 OPERATION

Control changes have been made to all 3 editionsand more are coming!

Hydro

Traction

Page 18: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 18

Note: These 4 requirements are often mixed up.

Control Changes

• Power – Supply to controller is altered in type, phase or voltage (not a new Main Line)

• Controller is replaced w/o change to Motion or Operation – could be a relay to microprocessor

• Type of Motion - such as MG to SSD or VVVF

• Type of Operation – Car Switch to Automatic

Page 19: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 19

Note: Hydro control change may not require change to fire service.

Control Changes

• 8.7.2.28 Emergency Operations

• 8.7.3.31.8 Emergency OperationsRationale: To clarify the requirements when installing firefighters’ emergency

operation on existing controllers.

(a)

(a)

Page 20: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 20

Work in Progress A17.1-2013

Page 21: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 21

Work in Progress A17.1-2013

Page 22: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 22

8.9 Code Data Plate

Page 23: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 23

Introduction

HISTORY

• A17.1-1996 - 1200.6 Effective July 1, 1997

• A17-1-2000 - Sect. 8.9 Effective March 23, 2002– To be used for Inspections & Tests - 8.10.1.2– Also see A17.2 - Item 10.14– Maintenance 8.6.1.5– Alterations 8.7.1.8

• All new, modernized and existing equipment are required to have a Code Data Plate

Page 24: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 24

SECTION 8.9 CODE DATA PLATE (in A17.1a-2005)Requirement 8.9 contains requirements for all new and existing equipment within the Scope of this Code.8.9.1 Required InformationData plate shall be provided and maintained that shall indicate the Code to be used for inspections and tests (see 8.10.1.2). The data plate shall indicate the Code and edition in effect at the time of installation. The data plate shall also indicate the Code in effect at the time of any alteration and indicate the applicable requirements of 8.7.8.9.2 LocationThe data plate shall be in plain view, securely attached to the main line disconnect or on the controller.8.9.3 Material and ConstructionThe data plate shall be of such material and construction that the letters and figures stamped, etched, cast, or otherwise applied to the face shall remain permanently and readily legible. The height of the letters andfigures shall be not less than 3.2 mm (0.125 in.).

Page 25: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 25

SECTION 8.9 CODE DATA PLATE (2007, a-08, b-09 & 2010)Requirement 8.9 contains requirements for all newand existing equipment within the Scope of this Code.8.9.1 Required InformationData plate shall be provided and maintained for each unit (see 1.1.1)that .The data plate shall indicate the Code to be used for inspections and tests (see 8.10.1.2). The data plate shall indicate the Code andedition in effect at the time of installation. The data plateshall also indicate the Code in effect at the time of anyalteration and indicate the applicable requirements of 8.7.8.9.2 LocationThe data plate shall be in plain view, securely attachedto the main line disconnect or on the controller. It shallalso be permitted to locate the data plate in the controlleras long as it is in plain view with the controller door open. An additional data plate shall be installed in thevicinity of one of the starting switch on the exterior of escalatorsand moving walks.

(07)

(b)

(10)

(10)

(10)

Page 26: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 26

SECTION 8.9 CODE DATA PLATE (2007, a-08, b-09 &2010)

(10)

8.9.3 Material and ConstructionThe data plate shall be of such material and construction that the letters and figures stamped, etched, cast, or otherwise applied to the face shall remain permanently and readily legible. The height of the letters and figures shall be not less than 3.2 mm (0.125 in.). All data plates not located in the controller shall be provided with either (a) a durable means to prevent common contaminants (such as paint, adhesives, oil, and grease) from adhering to the data plate parent surface and permit the removal of these contaminants, without obscuring the Code required data, or (b) letters and figures that are raised or depressed a minimum of 0.8 mm (0.03125 in.) from the plate surface face, and have a minimum character-stroke width of 0.5 mm (0.02 in.) If the plates are exposed to weathering or a chemical atmosphere, then a durable means shall be provided to protect the information from deterioration while permitting the information to be easily read.

Page 27: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 27

CDP Flow ChartDetermine the Original Maufacturer and serial number of the base equipment.

Determine date of Manufacture from Cross Head Data Plate

Contacted Manufacturer to obtain the Installation Code

Order Proper Code Data Plate

Have there been Alterations?

No

Yes

Yes

No

Yes

Determine building construction period - estimate elevator install permit date

Determine the Modernization Installer and Date

START

Yes

No

Subtract time from permit to manufacture (6-18 months)

Determine code in effect from AHJ for the estimated permit date

Determine scope of alterations and the applicable alteration rules and the applicable alteration code edition

Install Code Data Plate on Controller or Main Line Disconnect

FINISH

Page 28: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

28

SECTION 8.9 Requirement 8.9 contains requirements for all new and existing equipment within the Scope of this Code.

8.9.1 Required Information Data plate shall be provided and maintained that shall indicate the Code to be used for inspections and tests (see 8.10.1.2). The data plate shall indicate the Code and edition in effect at the time of installation.

The data plate shall also indicate the Code in effect at the time of any alteration

codedataplate.com

INSTALLATION CODE: ASME A17.1a-1997

CODE DATA PLATE

ALTERATION CODE: ASME A17.1a-2005

and indicate the applicable requirements of 8.7.

#REF!

codedataplate.com

8.7.2.11.5, 8.7.3.8, 8.7.3.24, 8.7.3.29, 8.7.3.30, 8.7.3.31.1, 8.7.3.31.2, 8.7.3.31.5, 8.7.3.31.8

SECT. 8.7 REQUIREMENTS COMPLIED WITH:

Page 29: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 29

Code Edition• Code to which the conveyance was

manufactured and installed to be used for inspections and tests.

• Original Installation Date– Elevator Permit Date– Other Dates If Unknown (X-Head,

Controller, Corner stone, etc.)

• Original Installation Code– Virginia Adoption Dates

Page 30: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 30

When is Code Effective?• Date of Contract?

• Date of Permit?

• Date of Inspection?

If Alteration, What Rules Apply?• Only work done by Elevator Contractor now?

• All alterations since installation?

• Only alterations now part of the installation?

Page 31: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 31

VUSBC BOCA Effective Date A17.1 edition2009 Edition ** January 3, 2011 b-20092006 Edition ** May 1, 2008 a-20052003 Edition ** November 16, 2005 b-20032000 Edition ** October 1, 2003 b-19981996 Edition 1996 September 15, 2000 -19931993 Edition 1993 April 1, 1994 -19901990 Edition 1990 March 1, 1991 -19871987 Edition 1987 March 1, 1988 -19841984 Edition 1984 April 1, 1986 -19811981 Edition 1981 July 16, 1982 19781978 Accumulative Supplement 1978 August 1, 1978 19711975 Accumulative Supplement 1975 February 7, 19761974 Accumulative Supplement 1970 w/'72 admend. April 1, 19741973 Edition 1970 w/'72 admend. September 1, 1973 -1965

Virginia

Page 32: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 32

CodeEdition StartDate EndDateASME A17.1b-2009 January 3, 2011ASME A17.1a-2005 May 1, 2008 January 2, 2011ASME A17.1b-2003 November 16, 2005 April 30, 2008ASME A17.1b-1998 October 1, 2003 November 15, 2005ASME A17.1-1993 September 15, 2000 September 30, 2003ASME A17.1-1990 April 1, 1994 September 14, 2000

ASME/ANSI A17.1-1987 March 1, 1991 March 31, 1994ANSI/ASME A17.1-1984 March 1, 1988 February 28, 1991ANSI/ASME A17.1-1981 April 1, 1986 February 29, 1988

ANSI A17.1-1978 July 16, 1982 March 31, 1986ANSI A17.1-1971 August 1, 1978 July 15, 1982ASA A17.1-1965 September 1, 1973 July 31, 1978ASA A17.1-1960 June 1, 1961 August 31, 1973ASA A17.1-1955 May 1, 1957 May 31, 1961ASA A17.3-1942 October 1, 1947 April 30, 1957

Virginia

Page 33: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 33

Page 34: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 34

Alteration Edition• Code to which the conveyance was

altered (modernized) to be used for inspections and tests.

• Alteration Date– Elevator Alteration Permit Date– Other Dates If Unknown (Controller,

Contact, etc.)

• Alteration Code– Virginia Adoption Dates

Page 35: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 35

Alteration Requirements (Rules)

• Applicable requirements of 8.7 (or of Part XII) complied with. 8.7.1 General Requirements 8.7.2 Electric Elevator Requirements 8.7.3 Hydraulic Requirements 8.7.4 thru 8.7.7 Other ConveyancesAppendix L (Table 1200)Alteration Pocket Guide - Handout

Page 36: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 36

Page 37: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 37

8.7.1 General RequirementsTRACTION HYDRO

8.7.2 8.7.38.7.2.1 Hoistway 8.7.3.18.7.2.2 Pits 8.7.3.28.7.2.7 Machine room 8.7.3.78.7.2.8 Wiring 8.7.3.88.7.2.10 Entrances 8.7.3.10

8.7.2.10.1 General <<<<8.7.2.10.2 Horizontal Slide <<<<8.7.2.10.3 Vertical Slide <<<<8.7.2.10.4 Swing Type <<<<

8.7.2.11 Hoistway Door 8.7.3.118.7.2.11.1 Interlocks <<<<8.7.2.11.4 Access Sw. (App. R) <<<<8.7.2.11.5 Door Restrictor <<<<

8.7.2.12 Operators 8.7.3.128.7.2.13 Re-opening Device <<<<8.7.2.14 Cabs 8.7.3.13

8.7.2.14.1 New Cab <<<<8.7.2.14.2 Cab Alt. Except panels <<<<8.7.2.14.3 Cab Alt. Interiors only <<<<8.7.2.14.5

8.7.2.15 Frame, Plat. & Guides 8.7.3.148.7.2.16 Load and Class

8.7.2.16.1 Type of Service 8.7.3.178.7.2.16.2 Class of Loading 8.7.3.188.7.2.16.3 Pass on Freight 8.7.3.198.7.2.16.4 Increase Rated Load 8.7.3.20

8.7.2.17 Travel or Speed 8.7.3.228.7.2.18 Safeties 8.7.3.15

Code Data Plate (8.6.1.5) Alteration Pocket Guide

For complete list see A17.1 Sect. 8.7 & App. L

Remove Stop Switch (before b-2003)

TRACTION HYDRO8.7.2.19 Governor 8.7.3.168.7.2.20 Rope Brake, etc.

Hydraulic Jack 8.7.3.23.1Hydraulic Cylinder only 8.7.3.23.3Move Power Unit 8.7.3.23.6Plunger Gripper 8.7.3.23.7Valve & Piping 8.7.3.24

8.7.2.21 Ropes 8.7.3.258.7.2.22 Counterweights 8.7.3.26

8.7.2.22.3 Cwt. Guides <<<<8.7.2.23 Buffers 8.7.3.278.7.2.24 Rails 8.7.3.28

Tank 8.7.3.298.7.2.25 Machines8.7.2.26 Terminal Stopping 8.7.3.308.7.2.27 Control Equipment 8.7.3.31

8.7.2.27.1 Top of Car 8.7.3.31.18.7.2.27.2 Leveling 8.7.3.31.2

Anti-Creep 8.7.3.31.38.7.2.27.3 Power Supply 8.7.3.31.48.7.2.27.4 Controller 8.7.3.31.58.7.2.27.5 Type of Motion 8.7.3.31.68.7.2.27.6 Type of Operation 8.7.3.31.7

Emergency Lowering 8.7.3.31.98.7.2.27.7 Remove Stop Switch* 8.7.3.31.10

8.7.2.28 Emerg. Operations 8.7.3.31.88.7.4 Other Driving Machines8.7.5 Special Applications8.7.6 Escalators & MW8.7.7 Dumbwaiters & ML

CodeDataPlate.com281/257-0516

*A17.1b-2003 and later editions only

Page 38: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 38

Page 39: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 39

Page 40: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 40

Job Information

Web, e-mail, phone or fax

Page 41: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

41

Code Data Plate Order FormModernization Items - check those that apply and provide additional in blanks:

Alteration to Hoistway: Ascending Car/unintended Movement Protection

Hoistway Ventilation Change in Number of Ropes

Mach. Room Access: Addition of Rope Equalizers

Mach. Rm. Alteration: Addition of Auxiliary Rope-Fastening Devices

Replace or alter Wiring Alteration to cwt:

Horizontal Slide Entrance(s) added Installation of or Alteration to Cwt. Roller Guides

Vertical Bi-Parting Entrance(s) Alteration to Car or Cwt. Buffers or Bumpers

Tracks and/or Hangers Replaced Alteration of Guide Rails, Supports and Fastenings

Interlocks Replaced Alteration to Machine, Motor or Sheaves

HW Access and/or Unlocking Device Alteration Change in location of Driving Machine

Door restrictors added Alteration to Terminal-Stopping Devices

Door Operator added or altered Addition of or alteration to Top of Car Operating Device

Door Re-Opening devise added or altered Addition of or alteration to Car leveling or Truck-Zoning Device

Complete New Cab Change of Main Power Supply

Remodel Existing Cab: Controller change

Alteration of Car Frame or Platform Change in Type of Motion Control (AC, DC, VV, SCR, etc.)

Installation of or Alteration to Car Roller Guides Change in Type of Operation Control (Car Sw., Automatic, etc.)

Increase/Decease Deadweight of Car more than 5% Charge to Emergency Operations or Signaling devices

Change in Type of Service Installation of new Hydraulic Jack

Change in Class of Loading Install or alter Plunger

Change to carry Passengers on Freight elevator Install, alter or sleeve Cylinder

Increase in Rated Load Increase Working Pressure

Increase or Decrease Travel Change location of Hydro Jack

Increase in Rated Speed Relocation of Hydraulic Machine to below top of Cylinder

Decrease in Rated Speed Installation of Plunger Gripper

Replace or install New Car Safety Change to Valves, Pressure Piping & Fittings

Replace or install New Cwt. Safety Install or alter Tank

Alter Existing Car or Cwt. Safety Alter Anti-Creep Leveling device

Alter or install New Speed Governor Install or alter Emergency Lowering

Other items modernized, comments or any additional Information:____________________________________________________________________________________________________________________

Page 42: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 42

Custom Software

Page 43: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 43

Custom Software

Page 44: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 44

Alteration Code Data Plate

#REF!

codedataplate.com

ALTERATION CODE: ASME A17.1-2000

SECT. 8.7 REQUIREMENTS COMPLIED WITH:

8.7.2.11.5, 8.7.2.13, 8.7.3.8, 8.7.3.12, 8.7.3.23.7, 8.7.3.24, 8.7.3.29, 8.7.3.30, 8.7.3.31.1, 8.7.3.31.2, 8.7.3.31.5, 8.7.3.31.8

CODE DATA PLATE

INSTALLATION CODE: ASA A17.1-1965

Door Operator

Wiring

Re-opening Devise

Door Restrictor

Plunger Gripper

Valve

Tank

Limits

Top of Car Insp..

Leveling

Controller Replacement

Emergency Operations

Page 45: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 45

#REF!

codedataplate.com

8.7.3.8, 8.7.3.24, 8.7.3.29, 8.7.3.30, 8.7.3.31.5, 8.7.3.31.8.

United Elevator Services Co. DTD-2569A

CODE DATA PLATE

SECTION 8.7 REQUIREMENTS COMPLIED WITH:

INSTALLATION CODE: ANSI/ASME A17.1-1984

ALTERATION CODE: ASME A17.1b-2003

Page 46: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 46

Page 47: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 47

Changes affecting Inspection Tags

in Sections 8.6 and 8.11

A17.1-2007 EditionAddenda a-2008 & b-2009

A17.1-2010 Edition

Page 48: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 48

Section 8.62007 vs. a-2008 & b-2009

(when testing rules were moved)

Errors to be aware of - an errata wasn’t published

Corrections were made in A17.1-2010

Page 49: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 49Inquiry on a-08: Does 8.6.12 apply now to all equipment not just Canada?

a-2008 b-2009SECTION 8.6MAINTENANCE, REPAIR, REPLACEMENT,AND TESTING

SECTION 8.6MAINTENANCE, REPAIR, REPLACEMENT,AND TESTING

Requirement 8.6 applies to maintenance, repairs,replacements, and testing. _________________________________________________________________________________________________________NOTES:(1) See 8.7 for alteration requirements.(2) See General in Preface for assignment of responsibilities.

Requirement 8.6 applies to maintenance, repairs,replacements, and testing.NOTES:(1) See 8.7 for alteration requirements.(2) See “General” in Preface for assignment of responsibilities.

These is no 8.6.12 in b-2009

Page 50: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 50

8.6.12 Maintenance of Elevators, Dumbwaiters,Escalators, and Moving Walks8.6.12.1 Scope8.6.12.1.1 Requirement 8.6.12 applies to allexisting installations and all new installations that havebeen placed in service. It provides the minimum standardsfor these installations. However, it is not the intentof this Section to require the alteration or replacement ofequipment to meet design, nameplate, and performancestandards not required by an earlier edition of this Codethat was in force at the time the equipment was installed.8.6.12.1.2 Requirement 8.6.12 applies also to themaintenance of other devices, analogous in design andusage, that are covered by this Code, such as material lifts.

ASME A17.1a-2008/CSA B44a-08

Canadian - NBCC

Page 51: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 51

ASME A17.1a-2008/CSA B44a-08

Page 52: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 52

ASME A17.1a-2008/CSA B44a-08

Page 53: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 53

ASME A17.1a-2008/CSA B44a-08

Page 54: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 54

ASME A17.1a-2008/CSA B44a-08

NOTES:(1) See 8.7 for alteration requirements.(2) See “General” in Preface for assignment ofresponsibilities.”Please note that TN 02-4174, which has been approved by theA17 Standards Committee for the 2009 edition, subsequentlydeletes the second and third sentences and 8.6.12.

Page 55: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 55

Traction Elevator - Periodic Test REQ. Tag Person or Firm Performing Test:

Test Category: 1 REQ. #<2007|| a-2008> Test Item Test Date 8.11.2.2.1 || 8.6.4.19.1 Car Oil Buffer 8.11.2.2.1 || 8.6.4.19.1 Counterweight Oil Buffer 8.11.2.2.2 || 8.6.4.19.2 Car Safety 8.11.2.2.2 || 8.6.4.19.2 Counterweight Safety 8.11.2.2.3 || 8.6.4.19.3 Car Governor 8.11.2.2.3 || 8.6.4.19.3 Counterweight Governor 8.11.2.2.4 || 8.6.4.19.4 Slack Rope Device (WD only) 8.11.2.2.5 || 8.6.4.19.5 Terminal Stopping Devices 8.11.2.2.6 || 8.6.4.19.6 Firefighter’s Emerg. Oper. 8.11.2.2.7 || 8.6.4.19.7 Standby/Emerg. Power Oper. 8.11.2.2.8 || 8.6.4.19.8 Door Closing Force & KE 8.11.2.2.9 || 8.6.4.19.9 Broken Rope or Tape Switch 8.11.2.2.10 || 8.6.4.19.10 E/E/PES checkout 8.11.2.2.11 || 8.6.4.19.11 ACOSP/UCM Tests (2010 >) || 8.6.4.19.12 Traction Loss Detection (2010 >) || 8.6.4.19.13 BSM & RS Detection Means cdp

Page 56: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 56

Inquiry: Are Escalators no longer required to be tagged?

Approved TN 02-3392 is what is shown in 2007 - 8.11.1.6 where did the language in a-2008 and b-2009 come from?

a-2008 b-20098.6.1.7.2 ________ A test _____ tag with the test date, the_________ requirement _ number requiring the test, and thename of the person or firm performing the test shall beinstalled inthe machine room _______ for all Category 1 and 5 tests forelectric elevators and Category 1, 3, and 5 tests forhydraulic elevators._________

8.6.1.7.2 ________ A test _____ tag with the test date, the_________ requirement _ number requiring the test, and thename of the person or firm performing the test shall beinstalled inthe machine room _______ for all Category 1 and 5 tests forelectric elevators and Category 1, 3, and 5 tests forhydraulic elevators._________

?

Page 57: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 57

Page 58: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 58

Escalators & Moving Walk – Periodic Test REQ. Tag Person or Firm Performing Test:

Test Category: 1 REQ. #<2007 || a-2008> Test Item Test Date 8.11.4.2.1 ||8.6.8.15.1 Machine Space Access 8.11.4.2.2 ||8.6.8.15.2 Machine Space Stop Switch 8.11.3.2.3 ||8.6.8.15.3 Controller and Wiring 8.11.4.2.4 ||8.6.8.15.4 Drive Machine & Brake Torque Test 8.11.4.2.5 ||8.6.8.15.5 Speed Governor 8.11.4.2.6 ||8.6.8.15.6 Broken Drive Chain Device 8.11.4.2.7 ||8.6.8.15.7 Reversal Stop Device 8.11.4.2.8 ||8.6.8.15.8 Broken Step-Chain/Treadway Device 8.11.4.2.9 ||8.6.8.15.9 Escalator Step Upthrust Device 8.11.4.2.10 ||8.6.8.15.10 Missing Step/Pallet Device 8.11.4.2.11 ||8.6.8.15.11 Step/Pallet Level Device 8.11.4.2.12 ||8.6.8.15.12 Step/Pallets, Chain and Trusses 8.11.4.2.13 ||8.6.8.15.13 Handrail Safety System Entry Device

and Speed Monitoring

8.11.4.2.14 ||8.6.8.15.14 Heaters Outdoor Units 8.11.4.2.15 ||8.6.8.15.15 Permissible Stretch of Esc. Step Chain 8.11.4.2.16 ||8.6.8.15.16 Disconnected Motor Device 8.11.4.2.17 ||8.6.8.15.17 Response to Smoke Detectors 8.11.4.2.18 ||8.6.8.15.18 Comb/Step/Pallet Impact Device 8.11.4.2.19 ||8.6.8.15.19 Esc. Step/Skirt Performance Index 8.11.4.2.20 ||8.6.8.15.20 Esc. Clr. Step and Skirt (Loaded Gap) 8.11.4.2.21 ||8.6.8.15.21 Inspection Controls 8.11.4.2.22 ||8.6.8.15.22 Esc. Step Lateral Displace Device (2010 >) || 8.6.8.15.23 Seismic Switch Operation Test

cdp

Page 59: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 59

Approved TN 02-3392 moved all test tagging requirements to 8.11.1.6 as it appears in A17.1-2007 - but

Page 60: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 60

Inquiry: Did the Releasing Carrier Tag come back in a-2008?

Page 61: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 61

Page 62: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 62

Page 63: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 63

Approved TN 02-3392 moved all test tagging requirements to 8.11.1.6 as it appears in A17.1-2007 - but

Page 64: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 64

Inquiry: Did the Buffer Test Tag come back in a-2008?

Page 65: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 65

Page 66: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 66

Approved TN 02-3392 changed several additional items (in a, b, f and h) to be tested in A17.1-2007 - but

Page 67: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 67

Inquiry: Are test of Overspeed Switch and checking for the seal no longer required in a-2008? Ref. 8.6.4.20.5 should be 8.6.4.19.5 and all 8.6.4.18 references should be 8.6.4.19!

Page 68: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 68

Page 69: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 69

Hydraulic Elevator - Periodic Test REQ. Tag Person or Firm Performing Test:

Test Category: 1 REQ. #<2007 || a-2008> Test Item Test Date 8.11.3.2.1 ||8.6.5.14.1 Relief Valve & System Pressure 8.11.3.2.2 ||8.6.5.14.2 Cylinder & Pressure Piping 8.11.3.2.3(a) ||8.6.5.14.3(a) Normal Terminal Stopping Device 8.11.3.2.3(b) ||8.6.5.14.3(b) Governors 8.11.3.2.3(c) ||8.6.5.14.3(c) Safeties 8.11.3.2.3(d) ||8.6.5.14.3(d) Oil Buffers 8.11.3.2.3(e) ||8.6.5.14.3(e) Firefighter’s Emerg. Oper. 8.11.3.2.3(f) ||8.6.5.14.3(f) Standby/Emerg. Power Oper. 8.11.3.2.3(g) ||8.6.5.14.3(g) Power Operation of Doors 8.11.3.2.3(h) ||8.6.5.14.3(h) Terminal Speed Reducing 8.11.3.2.3(i) ||8.6.5.14.3(i) Low Oil Protection 8.11.3.2.4 ||8.6.5.14.4 Flexible Hose & Fitting 8.11.3.2.5 ||8.6.5.14.5 Pressure Switch (2010 >) || 8.6.5.14.6 Power Operation of Doors (2010 >) || 8.6.5.14.7 Slack Rope Device

cdp

Page 70: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 70

Approved TN 02-3392 required only in Canada a tag to be placed on the governor after the test in A17.1-2007 - but

Page 71: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 71

Inquiry: Is the Governor Test Tag no longer required in a-2008 for jurisdictions enforcing NBCC?

Page 72: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 72

Page 73: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 73

Section 8.62007 vs. a-2008 & b-2009

Recommendation:Mark-up errors in 8.6 and

Don’t replace the pages in 8.11until an errata is published

(most errors were in moving of tests to 8.6)

2010 is correct

Page 74: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 74

Section 8.10approved forA17.1-2013

Test Tags for Acceptance Tests

Page 75: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

75

Electric Elevator - Acceptance Test Tag – DO NOT REMOVE

Person or Firm Performing Test: Date:

Witnessed by: QEI #

REQ. # Devices Tested/ Test Results of Tests 8.10.2.2.1(h) Door Closing Force Test 8.10.2.2.1(i) Door Closing Time Test 8.10.2.2.1(j)(1) Door Opening 8.10.2.2.1(j)(2) Leveling Zone and Speed 8.10.2.2.1(j)(3) Inner Landing Zone 8.10.2.2.1(q) Emergency / Standby Power Test 8.10.2.2.2(v) Braking System Test 8.10.2.2.2(y)(3) Winding Drum Machines Slack Rope 8.10.2.2.2(y)(6) W.D. Mach. Final Terminal Stopping 8.10.2.2.2(cc)(a) Emergency Stop 8.10.2.2.2(cc)(3) Traction Limit 8.10.2.2.2(ff) Terminal Stopping Devices Test 8.10.2.2.2(hh) Governors Overspeed Test 8.10.2.2.2(ii) Car Safety Test 8.10.2.2.2(ii)(2) Car Safety Type ‘A’ inertia app. Test 8.10.2.2.2(ii) Counterweight Safety Test 8.10.2.2.2(ii)(2) Cwt Safety Type ‘A’ inertia app. Test 8.10.2.2.2(jj)(1) Ascending Car OS Protection Test 8.10.2.2.2(jj)(2) Unintended Car Movement Test 8.10.2.2.2(mm) Emergency Brake 8.10.2.2.3(d) Top Car Clearance / Refuge Space 8.10.2.2.3(ff) Unexpected Car Movem. (top-of-car) 8.10.2.2.5(c) Car Oil Buffer Test 8.10.2.2.5(c) Counterweight Oil Buffer Test 8.10.2.2.5(l) Unexpected Car Movement (pit) 8.10.2.2.6 Firefighters’ Emergency Operation cdp

Page 76: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

76

Hydraulic Elevator Acceptance Test Tag – DO NOT REMOVE Person or Firm Performing Test: Date:

Witnessed by: QEI # REQ. # Devices Tested/ Test Results of Tests

8.10.3.2.1(h) Door Closing Force Test 8.10.3.2.1(i) Door Closing Time Test 8.10.3.2.1(j) Door Opening 8.10.3.2.1(q)(1) Emergency / Standby Power Test 8.10.3.2.1(q)(2) Auxiliary Power Lowering 8.10.3.2.2(s)(6) Phase Protection 8.10.3.2.2(s)(7) Low Oil Protection 8.10.3.2.2(t) Working Pressure Verification 8.10.3.2.2(u) Relief Valve Setting Test 8.10.3.2.2(y) Supply Line & Shutoff Valves 8.10.3.2.2(z) Hydraulic Cylinder Plunger Stop 8.10.3.2.2(aa) Press. Sw. Test (Cyl. top above tank) 8.10.3.2.2(bb) Recycle Oper. Test (Mult. or Tel.Cyl.) 8.10.3.2.2(cc) Static Controls 8.10.3.2.2(ee) Operating Devises 8.10.3.2.2(ff) Governor Overspeed 8.10.3.2.2(hh) Class C2 Freight Elevators 8.10.3.2.3(d) Top Car Clearance / Refuge Space 8.10.3.2.3(e) Normal Terminal Stopping Device 8.10.3.2.3(e) Terminal Stopping Device 8.10.3.2.3(f) Terminal Speed Reducing 8.10.3.2.3(g) Car Lev. & Anticreep Oper. Test 8.10.3.2.3(dd) Safety Inertia Application Test 8.10.3.2.3(ff) Unexpected Car Movem. (top-of-car) 8.10.3.2.5(b) Bot. Clear., Refuge Space & Runby 8.10.3.2.5(c)(3)(a) Plunger Clearance Bottom of Cyl. 8.10.3.2.5(e) Normal Terminal Stopping Device 8.10.3.2.5(j) Car Safety 8.10.3.2.5(n) Plunger Gripper Test 8.10.3.2.5(o) Overspeed Valve Test 8.10.3.2.6 Firefighters’ Emergency Operation

cdp

Page 77: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 77

Typical Data Plate Violations• A17.1-2000 and later editions Part 8

• A17.3-1996 and later editions

8.6.1.6.7 Signs and Data Plates. Required signsand data plates that are damaged or missing shall berepaired or replaced.

8.6.1.5 Code Data Plate8.6.1.5.1 A data plate that indicates the Codeand edition in effect at the time of installation and anyalteration (see 8.7.1.8) shall be provided. The data plateshall also specify the Code and edition in effect at thetime of any alteration and the applicable requirementsof 8.7.8.6.1.5.2 The Code data plate shall complywith 8.9.

3.5.6 Rail Lubricants and Lubrication Plate…A metal plate shall be securely attached to the car crosshead…

Page 78: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 78

8.6.1.6.7 Check for any Missing or Damaged Signs and Data Plates

• Machine Room– Brake Plates

– Governor Plate

– Code Data Plate

– Ambient Air Plate

– Hydro Data Plates

– Warning Signs

• Fire Service Signs

• Hoistway and Pit– Crosshead Data Plate

– Rail Lube Instructions

– Warning Signs

– Safety Plank Plate

– Buffer Plate

– Counterweight Runby

• Freight & Capacity

Page 79: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 79

● ●

POUNDS F.P.M.

NUMBER OF ROPES: IN.

MANUFACTURED: BY:

RAIL LUBRICATION INSTRUCTIONS:

● ●

RATED BREAKING STRENGTH: POUNDS

the safety for the characteristics of the rail lubricant to be used.

DIAMETER:

RATED SPEED:

COMPLETE CAR WEIGHT:

RATED LOAD:

POUNDS

CROSSHEAD DATA PLATE

codedataplate.com

INSTALLATION CODE: ASME A17.1a-1997

CODE DATA PLATE

#REF!SECT. 8.7 REQUIREMENTS COMPLIED WITH:

8.7.2.11.5, 8.7.2.28.

CODE DATA PLATEINSTALLATION CODE: ANSI A17.1-1978

ALTERATION CODE: ASME A17.1-2000

codedataplate.com

MAXIMUM COUNTERWEIGHT

RUNBY 24"

● ●

NORMAL

REDUCED

DOOR OPERATOR DATA PLATE

Seconds

Seconds

cdp ●

● ●

● CDP ●

LOAD RATING: 6000 POUNDS

NUMBER OF SPRINGS: 2

BUFFER MARKING PLATE

STROKE: 2 1/2 INCHES

● ●

● cdp ●

DO NOT LUBRICATE

RAIL LUBRICATION INSTRUCTIONS:

Page 80: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 80

Products

codedataplate.com

INSTALLATION CODE: ASME A17.1a-1997

CODE DATA PLATE

SECT. 8.7 REQUIREMENTS COMPLIED WITH:

CODE DATA PLATE

INSTALLATION CODE: ANSI A17.1-1971

ALTERATION CODE: ASME A17.1-2000

8.7.2.1.5, 8.7.2.8, 8.7.2.11.5, 8.7.2.12, 8.7.2.13, 8.7.2.14.3, 8.7.2.19, 8.7.2.20, 8.7.2.25.1(b), 8.7.2.27.1, 8.7.2.27.2, 8.7.2.27.5, 8.7.2.28

codedataplate.com

#REF!PART XII RULES COMPLIED WITH:

codedataplate.com

1201.11, 1202.13.

ALTERATION CODE: ASME A17.1a-1994

INSTALLATION CODE: ANSI A17.1-1978

CODE DATA PLATE

#REF!

1200.5d, 1201.3, 1201.10b, 1201.11a, 1201.12, 1202.3c, 1202.4a, 1202.5a, 1202.11, 1202.12a, 1202.12b, 1202.12e, 1202.13

codedataplate.com

1P30777

PART XII RULES COMPLIED WITH:

CODE DATA PLATE

INSTALLATION CODE: NYC BC 1938 - Article 14

ALTERATION CODE: ASME/ANSI A17.1b-1989

● ●

NORMAL

REDUCED

DOOR OPERATOR DATA PLATE

Seconds

Seconds

cdp ●

X

At:

X

At:

● cdp ●

Building Office

MAINTENANCE CONTROL PROGRAM LOCATION

Machine Room

LOCATION OF MAINTENANCE RECORDS

●●

Machine Room Contact:

Building Office ||

Page 81: 7/25/12. 7/25/12 Disclaimer The opinions and recommendations presented here are strictly my own and are not

7/25/12 www.CodeDataPlate.com 81

Contact Information

[email protected]

office:281/257-0516cell: 832/239-2513