7/25/12. 7/25/12 disclaimer the opinions and recommendations presented here are strictly my own and...
TRANSCRIPT
7/25/12 www.CodeDataPlate.com 1
VIRGINIA ELEVATOR SAFETY ASSOCIATION
A17 Code Required Data Plates, Tags and Signs
what’s new and what’s not in A17.1-2007, a-2008, b-2009 & in
A17.1-2010by: John S. Rearick
CodeDataPlate.com
7/25/12 www.CodeDataPlate.com 2
Disclaimer
The opinions and recommendations presented here are strictly my own and are not those of ASME, NAESAI, IAEC or any organization of which I may be a member.
JSRearick
3
Who are we?• CodeDataPlate.com is the trade name of Rearick &
Company, Inc. – Elevator Consulting
• CodeDataPlate.com was formed 11 years ago to provide accurate on-site code information to inspectors when performing inspections.
• Started with just Code Data Plates (still 50% of our business)
• Grown to include – Crosshead Data Plates
– Inspection Tags
– Other code specific Data Plates, Tags & Signs
– Maintenance Control Program assistance & formatting
• Primary customer: Elevator Contractors
4
ASME A17 Involvement (since 1995)• Existing Installations, Chair
– Section 8.7 - Alterations
– A17.3 Code for Existing Installations
– Ex-Officio – Standards Committee
• Maintenance, Repair & Replacement– Section 8.6
– MCP Task Group
• Inspections– Sections 8.10, 8.11 and Testing parts of 8.6
– A17.2 Guide for Inspectors
• Wind Tower Elevator Committee• Inclined Elevator Committee• Ad Hoc Data Plate
5
Code Making Process• Inquiry
– Format: Edition and Requirement Number– Assigned to Working Committee to answer– Technical Revision (TN) Developed if needed
• Review and approved by Standards Comm.
• Interpretation published
• Approved TN’s go into Public Review Draft
• Finally are published in next Code Edition
7/25/12 www.CodeDataPlate.com 6
Changes affecting Code Data Plates
in Sections 8.7 and 8.9
A17.1-2007 EditionAddenda a-2008 & b-2009
A17.1-2010 Edition
7/25/12 www.CodeDataPlate.com 7
8.7 Summary of changes in 2007 Edition
8.7.1.7 Second sentence added8.7.1.8 Second sentence added8.7.2.1.3 Editorially revised8.7.2.1.4 Editorially revised8.7.2.7.6 Editorially revised8.7.2.7.7 Editorially revised8.7.2.15.2 Revised in its entirety8.7.2.17 Title editorially revised8.7.2.17.1 Title and paragraphs editorially revised8.7.2.17.2(b)(5) Editorially revised8.7.2.23 Revised in its entirety8.7.2.25.1(a) Editorially revised8.7.2.25.2(a) Editorially revised8.7.2.25.2(b) Editorially revised8.7.2.27.6 First paragraph revised8.7.2.27.8 Added
7/25/12 www.CodeDataPlate.com 8
8.7 and 8.9 Summary of changes in 2007 Edition
8.7.3.15.3 Editorially revised8.7.3.19 Editorially revised8.7.3.22 Title editorially revised8.7.3.22.1 First paragraph and subparagraphs
(b), (c), and (e) editorially revised8.7.3.23.1 Revised8.7.3.23.2 Revised8.7.3.23.3 Revised8.7.3.31.11 Added8.7.4.3.7 Title and paragraphs editorially revised8.7.6.1.1 Revised in its entirety8.7.6.1.5 Revised in its entirety8.7.6.1.9 Third paragraph deleted8.7.6.2.1 Revised8.9.2 Revisedand in 8.9
7/25/12 www.CodeDataPlate.com 9
8.7 Summary of changes in a-2008 Addenda
8.7.2.14.2(i) Added8.7.2.27.3 First paragraph revised8.7.2.27.4 (1) Subparagraph (a) revised (2) Subparagraph (c) added8.7.2.28 Revised in its entirety8.7.3.31.4 First paragraph revised8.7.3.31.5(a) Revised8.7.3.31.5(c) Added8.7.3.31.8(c) Revised8.7.5.3 Revised in its entirety8.7.5.4 Revised in its entirety
7/25/12 www.CodeDataPlate.com 10
8.7 and 8.9 Summary of changes in b-2009 Addenda
and in 8.9
7/25/12 www.CodeDataPlate.com 11
8.7 and 8.9 Summary of changes in 2010 Edition
8.7.2.1.1 (e) Access Door reference corrected 8.7.2.21 Title revised – Suspension Ropes to Means 8.7.2.21.1& .21.3 Ropes to Means 8.7.2.21.4 Added Monitoring & Protection 8.7.3.31.10 Editorially revised a reference 8.7.6.2.7 (a) Editorially revised references 8.7.6.2.9 Editorially revised a reference 8.7.6.2.12 (a) Editorially revised references 8.9.1 First and second sentences revised 8.9.2 First and last sentences revised 8.9.3 Revised added requirements
7/25/12 www.CodeDataPlate.com 12
8.7 Alterations
7/25/12 www.CodeDataPlate.com 13
Alteration Changes in A17.1-2007, a-08 & b-09 except control
• 8.7.1.7 Adds Canadian (NBCC) Exceptions
• 8.7.1.8 Adds Canadian (NBCC) Exceptions
• 8.7.2.1.3Editorial correction
• 8.7.2.1.4Editorial correction
• 8.7.2.7.1Now includes both machine & control spaces
• 8.7.2.7.6 Editorial correction
• 8.7.2.7.7 Editorial correction
• 8.7.2.10.1 Now includes 2.29.2 (4” number inside door)
• 8.7.2.14.2(i) Adds requirements for car door or gate
• 8.7.2.15.2 Revised Buffer requirements
• 8.7.2.17 Editorial correction
• 8.7.2.23 Revised Buffer requirements
• 8.7.2.25 Editorial correction
(a)(b)
(b)
7/25/12 www.CodeDataPlate.com 14
Alteration Changes in A17.1-2007, a-08 & b-09 except control
• 8.7.3.15.3 Editorial correction
• 8.7.3.19 Editorial correction
• 8.7.3.15 Editorial correction
• 8.7.3.19 Editorial correction
• 8.7.3.22 Editorial correction
• 8.7.3.23 Jacks are now stand alone alteration – see slide
• 8.7.4.3.7 Editorial correction (travel to rise in about 50 places)
• 8.7.5.3 Added Private Residence Requirements
• 8.7.5.4 Added Private Residence RequirementsReason: Many private residences have been converted to convention centers, banquet facilities, museums, etc.; where the elevators are used by the general public or as a Limited-Use/Limited-Application elevator. In these cases, the more stringent safety requirements of ASME A17.1 need to be applied.
• 8.7.6.1 Escalator alteration updated
• 8.7.6.2 Moving Walk alteration upgraded
(a)
(a)
7/25/12 www.CodeDataPlate.com 15
Alteration Changes in 2010 Edition
8.7.2.1.1 (e) Access Door reference corrected 8.7.2.21 Title revised – Suspension Ropes to Means 8.7.2.21.1& .21.3 Ropes to Means 8.7.2.21.4 Added Monitoring & Protection 8.7.3.31.10 Editorially revised a reference 8.7.6.2.7 (a) Editorially revised references 8.7.6.2.9 Editorially revised a reference 8.7.6.2.12 (a) Editorially revised references 8.9.1 First and second sentences revised 8.9.2 First and last sentences revised 8.9.3 Revised added requirements
7/25/12 www.CodeDataPlate.com 16
Note: These 3 requirements are often mixed up.
TN 03-1712
Revise A17.1 requirements 8.7.3.23.1, 8.7.3.23.2 and 8.7.3.23.3 as follows:
8.7.3.23.1 Hydraulic Jack. Where the alteration involves the installation of a hydraulic jack, it is installed,altered or replaced it shall conform to 3.18.
8.7.3.23.2 Plungers. Where a new plunger is installed as part of an alteration or an existing plunger isaltered, it shall conform to 3.18.1.2 and 3.18.2.
8.7.3.23.3 Cylinders. Where a cylinder is installed, replaced as part of an alteration, altered, or sleeved, itshall conform to 3.18.3. If the plunger is not equipped with a stop ring conforming to 3.18.4.1, theinstallation shall also conform to 3.18.1.2 and 3.18.2.
Reason:Requirement 8.6.3.10 identifies replacement of jacks, plungers, and cylinders as an alteration and referredto 8.7.3.23. This proposed change clarifies the need to comply with existing requirements even though thereplacement is not “part of an alteration”. (See new proposed definition in TN 02-3899 for “Alteration aspart of – A repair and/or replacement that is included with other work that is classified as an alteration”)
7/25/12 www.CodeDataPlate.com 17
Alteration Changes in A17.1-2007, a-08 & b-09 for control
• 8.7.2.27.8 and 8.7.3.31.11 Added
Electrical Protective Devices. Where there is an alteration to or addition of an electrical protective device, it shall conform to 2.26.2 for that device.
• 8.7.2.27.3 POWER
• 8.7.2.27.4 CONTROL REPLACEMENT
• 8.7.2.27.5 MOTION
• 8.7.2.27.6 OPERATION
• 8.7.3.31.4 POWER
• 8.7.3.31.5 CONTROL REPLACEMENT
• 8.7.3.31.6 MOTION
• 8.7.3.31.7 OPERATION
Control changes have been made to all 3 editionsand more are coming!
Hydro
Traction
7/25/12 www.CodeDataPlate.com 18
Note: These 4 requirements are often mixed up.
Control Changes
• Power – Supply to controller is altered in type, phase or voltage (not a new Main Line)
• Controller is replaced w/o change to Motion or Operation – could be a relay to microprocessor
• Type of Motion - such as MG to SSD or VVVF
• Type of Operation – Car Switch to Automatic
7/25/12 www.CodeDataPlate.com 19
Note: Hydro control change may not require change to fire service.
Control Changes
• 8.7.2.28 Emergency Operations
• 8.7.3.31.8 Emergency OperationsRationale: To clarify the requirements when installing firefighters’ emergency
operation on existing controllers.
(a)
(a)
7/25/12 www.CodeDataPlate.com 20
Work in Progress A17.1-2013
7/25/12 www.CodeDataPlate.com 21
Work in Progress A17.1-2013
7/25/12 www.CodeDataPlate.com 22
8.9 Code Data Plate
7/25/12 www.CodeDataPlate.com 23
Introduction
HISTORY
• A17.1-1996 - 1200.6 Effective July 1, 1997
• A17-1-2000 - Sect. 8.9 Effective March 23, 2002– To be used for Inspections & Tests - 8.10.1.2– Also see A17.2 - Item 10.14– Maintenance 8.6.1.5– Alterations 8.7.1.8
• All new, modernized and existing equipment are required to have a Code Data Plate
7/25/12 www.CodeDataPlate.com 24
SECTION 8.9 CODE DATA PLATE (in A17.1a-2005)Requirement 8.9 contains requirements for all new and existing equipment within the Scope of this Code.8.9.1 Required InformationData plate shall be provided and maintained that shall indicate the Code to be used for inspections and tests (see 8.10.1.2). The data plate shall indicate the Code and edition in effect at the time of installation. The data plate shall also indicate the Code in effect at the time of any alteration and indicate the applicable requirements of 8.7.8.9.2 LocationThe data plate shall be in plain view, securely attached to the main line disconnect or on the controller.8.9.3 Material and ConstructionThe data plate shall be of such material and construction that the letters and figures stamped, etched, cast, or otherwise applied to the face shall remain permanently and readily legible. The height of the letters andfigures shall be not less than 3.2 mm (0.125 in.).
7/25/12 www.CodeDataPlate.com 25
SECTION 8.9 CODE DATA PLATE (2007, a-08, b-09 & 2010)Requirement 8.9 contains requirements for all newand existing equipment within the Scope of this Code.8.9.1 Required InformationData plate shall be provided and maintained for each unit (see 1.1.1)that .The data plate shall indicate the Code to be used for inspections and tests (see 8.10.1.2). The data plate shall indicate the Code andedition in effect at the time of installation. The data plateshall also indicate the Code in effect at the time of anyalteration and indicate the applicable requirements of 8.7.8.9.2 LocationThe data plate shall be in plain view, securely attachedto the main line disconnect or on the controller. It shallalso be permitted to locate the data plate in the controlleras long as it is in plain view with the controller door open. An additional data plate shall be installed in thevicinity of one of the starting switch on the exterior of escalatorsand moving walks.
(07)
(b)
(10)
(10)
(10)
7/25/12 www.CodeDataPlate.com 26
SECTION 8.9 CODE DATA PLATE (2007, a-08, b-09 &2010)
(10)
8.9.3 Material and ConstructionThe data plate shall be of such material and construction that the letters and figures stamped, etched, cast, or otherwise applied to the face shall remain permanently and readily legible. The height of the letters and figures shall be not less than 3.2 mm (0.125 in.). All data plates not located in the controller shall be provided with either (a) a durable means to prevent common contaminants (such as paint, adhesives, oil, and grease) from adhering to the data plate parent surface and permit the removal of these contaminants, without obscuring the Code required data, or (b) letters and figures that are raised or depressed a minimum of 0.8 mm (0.03125 in.) from the plate surface face, and have a minimum character-stroke width of 0.5 mm (0.02 in.) If the plates are exposed to weathering or a chemical atmosphere, then a durable means shall be provided to protect the information from deterioration while permitting the information to be easily read.
7/25/12 www.CodeDataPlate.com 27
CDP Flow ChartDetermine the Original Maufacturer and serial number of the base equipment.
Determine date of Manufacture from Cross Head Data Plate
Contacted Manufacturer to obtain the Installation Code
Order Proper Code Data Plate
Have there been Alterations?
No
Yes
Yes
No
Yes
Determine building construction period - estimate elevator install permit date
Determine the Modernization Installer and Date
START
Yes
No
Subtract time from permit to manufacture (6-18 months)
Determine code in effect from AHJ for the estimated permit date
Determine scope of alterations and the applicable alteration rules and the applicable alteration code edition
Install Code Data Plate on Controller or Main Line Disconnect
FINISH
28
SECTION 8.9 Requirement 8.9 contains requirements for all new and existing equipment within the Scope of this Code.
8.9.1 Required Information Data plate shall be provided and maintained that shall indicate the Code to be used for inspections and tests (see 8.10.1.2). The data plate shall indicate the Code and edition in effect at the time of installation.
The data plate shall also indicate the Code in effect at the time of any alteration
codedataplate.com
INSTALLATION CODE: ASME A17.1a-1997
CODE DATA PLATE
ALTERATION CODE: ASME A17.1a-2005
and indicate the applicable requirements of 8.7.
#REF!
codedataplate.com
8.7.2.11.5, 8.7.3.8, 8.7.3.24, 8.7.3.29, 8.7.3.30, 8.7.3.31.1, 8.7.3.31.2, 8.7.3.31.5, 8.7.3.31.8
SECT. 8.7 REQUIREMENTS COMPLIED WITH:
7/25/12 www.CodeDataPlate.com 29
Code Edition• Code to which the conveyance was
manufactured and installed to be used for inspections and tests.
• Original Installation Date– Elevator Permit Date– Other Dates If Unknown (X-Head,
Controller, Corner stone, etc.)
• Original Installation Code– Virginia Adoption Dates
7/25/12 www.CodeDataPlate.com 30
When is Code Effective?• Date of Contract?
• Date of Permit?
• Date of Inspection?
If Alteration, What Rules Apply?• Only work done by Elevator Contractor now?
• All alterations since installation?
• Only alterations now part of the installation?
7/25/12 www.CodeDataPlate.com 31
VUSBC BOCA Effective Date A17.1 edition2009 Edition ** January 3, 2011 b-20092006 Edition ** May 1, 2008 a-20052003 Edition ** November 16, 2005 b-20032000 Edition ** October 1, 2003 b-19981996 Edition 1996 September 15, 2000 -19931993 Edition 1993 April 1, 1994 -19901990 Edition 1990 March 1, 1991 -19871987 Edition 1987 March 1, 1988 -19841984 Edition 1984 April 1, 1986 -19811981 Edition 1981 July 16, 1982 19781978 Accumulative Supplement 1978 August 1, 1978 19711975 Accumulative Supplement 1975 February 7, 19761974 Accumulative Supplement 1970 w/'72 admend. April 1, 19741973 Edition 1970 w/'72 admend. September 1, 1973 -1965
Virginia
7/25/12 www.CodeDataPlate.com 32
CodeEdition StartDate EndDateASME A17.1b-2009 January 3, 2011ASME A17.1a-2005 May 1, 2008 January 2, 2011ASME A17.1b-2003 November 16, 2005 April 30, 2008ASME A17.1b-1998 October 1, 2003 November 15, 2005ASME A17.1-1993 September 15, 2000 September 30, 2003ASME A17.1-1990 April 1, 1994 September 14, 2000
ASME/ANSI A17.1-1987 March 1, 1991 March 31, 1994ANSI/ASME A17.1-1984 March 1, 1988 February 28, 1991ANSI/ASME A17.1-1981 April 1, 1986 February 29, 1988
ANSI A17.1-1978 July 16, 1982 March 31, 1986ANSI A17.1-1971 August 1, 1978 July 15, 1982ASA A17.1-1965 September 1, 1973 July 31, 1978ASA A17.1-1960 June 1, 1961 August 31, 1973ASA A17.1-1955 May 1, 1957 May 31, 1961ASA A17.3-1942 October 1, 1947 April 30, 1957
Virginia
7/25/12 www.CodeDataPlate.com 33
7/25/12 www.CodeDataPlate.com 34
Alteration Edition• Code to which the conveyance was
altered (modernized) to be used for inspections and tests.
• Alteration Date– Elevator Alteration Permit Date– Other Dates If Unknown (Controller,
Contact, etc.)
• Alteration Code– Virginia Adoption Dates
7/25/12 www.CodeDataPlate.com 35
Alteration Requirements (Rules)
• Applicable requirements of 8.7 (or of Part XII) complied with. 8.7.1 General Requirements 8.7.2 Electric Elevator Requirements 8.7.3 Hydraulic Requirements 8.7.4 thru 8.7.7 Other ConveyancesAppendix L (Table 1200)Alteration Pocket Guide - Handout
7/25/12 www.CodeDataPlate.com 36
7/25/12 www.CodeDataPlate.com 37
8.7.1 General RequirementsTRACTION HYDRO
8.7.2 8.7.38.7.2.1 Hoistway 8.7.3.18.7.2.2 Pits 8.7.3.28.7.2.7 Machine room 8.7.3.78.7.2.8 Wiring 8.7.3.88.7.2.10 Entrances 8.7.3.10
8.7.2.10.1 General <<<<8.7.2.10.2 Horizontal Slide <<<<8.7.2.10.3 Vertical Slide <<<<8.7.2.10.4 Swing Type <<<<
8.7.2.11 Hoistway Door 8.7.3.118.7.2.11.1 Interlocks <<<<8.7.2.11.4 Access Sw. (App. R) <<<<8.7.2.11.5 Door Restrictor <<<<
8.7.2.12 Operators 8.7.3.128.7.2.13 Re-opening Device <<<<8.7.2.14 Cabs 8.7.3.13
8.7.2.14.1 New Cab <<<<8.7.2.14.2 Cab Alt. Except panels <<<<8.7.2.14.3 Cab Alt. Interiors only <<<<8.7.2.14.5
8.7.2.15 Frame, Plat. & Guides 8.7.3.148.7.2.16 Load and Class
8.7.2.16.1 Type of Service 8.7.3.178.7.2.16.2 Class of Loading 8.7.3.188.7.2.16.3 Pass on Freight 8.7.3.198.7.2.16.4 Increase Rated Load 8.7.3.20
8.7.2.17 Travel or Speed 8.7.3.228.7.2.18 Safeties 8.7.3.15
Code Data Plate (8.6.1.5) Alteration Pocket Guide
For complete list see A17.1 Sect. 8.7 & App. L
Remove Stop Switch (before b-2003)
TRACTION HYDRO8.7.2.19 Governor 8.7.3.168.7.2.20 Rope Brake, etc.
Hydraulic Jack 8.7.3.23.1Hydraulic Cylinder only 8.7.3.23.3Move Power Unit 8.7.3.23.6Plunger Gripper 8.7.3.23.7Valve & Piping 8.7.3.24
8.7.2.21 Ropes 8.7.3.258.7.2.22 Counterweights 8.7.3.26
8.7.2.22.3 Cwt. Guides <<<<8.7.2.23 Buffers 8.7.3.278.7.2.24 Rails 8.7.3.28
Tank 8.7.3.298.7.2.25 Machines8.7.2.26 Terminal Stopping 8.7.3.308.7.2.27 Control Equipment 8.7.3.31
8.7.2.27.1 Top of Car 8.7.3.31.18.7.2.27.2 Leveling 8.7.3.31.2
Anti-Creep 8.7.3.31.38.7.2.27.3 Power Supply 8.7.3.31.48.7.2.27.4 Controller 8.7.3.31.58.7.2.27.5 Type of Motion 8.7.3.31.68.7.2.27.6 Type of Operation 8.7.3.31.7
Emergency Lowering 8.7.3.31.98.7.2.27.7 Remove Stop Switch* 8.7.3.31.10
8.7.2.28 Emerg. Operations 8.7.3.31.88.7.4 Other Driving Machines8.7.5 Special Applications8.7.6 Escalators & MW8.7.7 Dumbwaiters & ML
CodeDataPlate.com281/257-0516
*A17.1b-2003 and later editions only
7/25/12 www.CodeDataPlate.com 38
7/25/12 www.CodeDataPlate.com 39
7/25/12 www.CodeDataPlate.com 40
Job Information
Web, e-mail, phone or fax
41
Code Data Plate Order FormModernization Items - check those that apply and provide additional in blanks:
Alteration to Hoistway: Ascending Car/unintended Movement Protection
Hoistway Ventilation Change in Number of Ropes
Mach. Room Access: Addition of Rope Equalizers
Mach. Rm. Alteration: Addition of Auxiliary Rope-Fastening Devices
Replace or alter Wiring Alteration to cwt:
Horizontal Slide Entrance(s) added Installation of or Alteration to Cwt. Roller Guides
Vertical Bi-Parting Entrance(s) Alteration to Car or Cwt. Buffers or Bumpers
Tracks and/or Hangers Replaced Alteration of Guide Rails, Supports and Fastenings
Interlocks Replaced Alteration to Machine, Motor or Sheaves
HW Access and/or Unlocking Device Alteration Change in location of Driving Machine
Door restrictors added Alteration to Terminal-Stopping Devices
Door Operator added or altered Addition of or alteration to Top of Car Operating Device
Door Re-Opening devise added or altered Addition of or alteration to Car leveling or Truck-Zoning Device
Complete New Cab Change of Main Power Supply
Remodel Existing Cab: Controller change
Alteration of Car Frame or Platform Change in Type of Motion Control (AC, DC, VV, SCR, etc.)
Installation of or Alteration to Car Roller Guides Change in Type of Operation Control (Car Sw., Automatic, etc.)
Increase/Decease Deadweight of Car more than 5% Charge to Emergency Operations or Signaling devices
Change in Type of Service Installation of new Hydraulic Jack
Change in Class of Loading Install or alter Plunger
Change to carry Passengers on Freight elevator Install, alter or sleeve Cylinder
Increase in Rated Load Increase Working Pressure
Increase or Decrease Travel Change location of Hydro Jack
Increase in Rated Speed Relocation of Hydraulic Machine to below top of Cylinder
Decrease in Rated Speed Installation of Plunger Gripper
Replace or install New Car Safety Change to Valves, Pressure Piping & Fittings
Replace or install New Cwt. Safety Install or alter Tank
Alter Existing Car or Cwt. Safety Alter Anti-Creep Leveling device
Alter or install New Speed Governor Install or alter Emergency Lowering
Other items modernized, comments or any additional Information:____________________________________________________________________________________________________________________
7/25/12 www.CodeDataPlate.com 42
Custom Software
7/25/12 www.CodeDataPlate.com 43
Custom Software
7/25/12 www.CodeDataPlate.com 44
Alteration Code Data Plate
#REF!
codedataplate.com
ALTERATION CODE: ASME A17.1-2000
SECT. 8.7 REQUIREMENTS COMPLIED WITH:
8.7.2.11.5, 8.7.2.13, 8.7.3.8, 8.7.3.12, 8.7.3.23.7, 8.7.3.24, 8.7.3.29, 8.7.3.30, 8.7.3.31.1, 8.7.3.31.2, 8.7.3.31.5, 8.7.3.31.8
CODE DATA PLATE
INSTALLATION CODE: ASA A17.1-1965
Door Operator
Wiring
Re-opening Devise
Door Restrictor
Plunger Gripper
Valve
Tank
Limits
Top of Car Insp..
Leveling
Controller Replacement
Emergency Operations
7/25/12 www.CodeDataPlate.com 45
#REF!
codedataplate.com
8.7.3.8, 8.7.3.24, 8.7.3.29, 8.7.3.30, 8.7.3.31.5, 8.7.3.31.8.
United Elevator Services Co. DTD-2569A
CODE DATA PLATE
SECTION 8.7 REQUIREMENTS COMPLIED WITH:
INSTALLATION CODE: ANSI/ASME A17.1-1984
ALTERATION CODE: ASME A17.1b-2003
7/25/12 www.CodeDataPlate.com 46
7/25/12 www.CodeDataPlate.com 47
Changes affecting Inspection Tags
in Sections 8.6 and 8.11
A17.1-2007 EditionAddenda a-2008 & b-2009
A17.1-2010 Edition
7/25/12 www.CodeDataPlate.com 48
Section 8.62007 vs. a-2008 & b-2009
(when testing rules were moved)
Errors to be aware of - an errata wasn’t published
Corrections were made in A17.1-2010
7/25/12 www.CodeDataPlate.com 49Inquiry on a-08: Does 8.6.12 apply now to all equipment not just Canada?
a-2008 b-2009SECTION 8.6MAINTENANCE, REPAIR, REPLACEMENT,AND TESTING
SECTION 8.6MAINTENANCE, REPAIR, REPLACEMENT,AND TESTING
Requirement 8.6 applies to maintenance, repairs,replacements, and testing. _________________________________________________________________________________________________________NOTES:(1) See 8.7 for alteration requirements.(2) See General in Preface for assignment of responsibilities.
Requirement 8.6 applies to maintenance, repairs,replacements, and testing.NOTES:(1) See 8.7 for alteration requirements.(2) See “General” in Preface for assignment of responsibilities.
These is no 8.6.12 in b-2009
7/25/12 www.CodeDataPlate.com 50
8.6.12 Maintenance of Elevators, Dumbwaiters,Escalators, and Moving Walks8.6.12.1 Scope8.6.12.1.1 Requirement 8.6.12 applies to allexisting installations and all new installations that havebeen placed in service. It provides the minimum standardsfor these installations. However, it is not the intentof this Section to require the alteration or replacement ofequipment to meet design, nameplate, and performancestandards not required by an earlier edition of this Codethat was in force at the time the equipment was installed.8.6.12.1.2 Requirement 8.6.12 applies also to themaintenance of other devices, analogous in design andusage, that are covered by this Code, such as material lifts.
ASME A17.1a-2008/CSA B44a-08
Canadian - NBCC
7/25/12 www.CodeDataPlate.com 51
ASME A17.1a-2008/CSA B44a-08
7/25/12 www.CodeDataPlate.com 52
ASME A17.1a-2008/CSA B44a-08
7/25/12 www.CodeDataPlate.com 53
ASME A17.1a-2008/CSA B44a-08
7/25/12 www.CodeDataPlate.com 54
ASME A17.1a-2008/CSA B44a-08
NOTES:(1) See 8.7 for alteration requirements.(2) See “General” in Preface for assignment ofresponsibilities.”Please note that TN 02-4174, which has been approved by theA17 Standards Committee for the 2009 edition, subsequentlydeletes the second and third sentences and 8.6.12.
7/25/12 www.CodeDataPlate.com 55
Traction Elevator - Periodic Test REQ. Tag Person or Firm Performing Test:
Test Category: 1 REQ. #<2007|| a-2008> Test Item Test Date 8.11.2.2.1 || 8.6.4.19.1 Car Oil Buffer 8.11.2.2.1 || 8.6.4.19.1 Counterweight Oil Buffer 8.11.2.2.2 || 8.6.4.19.2 Car Safety 8.11.2.2.2 || 8.6.4.19.2 Counterweight Safety 8.11.2.2.3 || 8.6.4.19.3 Car Governor 8.11.2.2.3 || 8.6.4.19.3 Counterweight Governor 8.11.2.2.4 || 8.6.4.19.4 Slack Rope Device (WD only) 8.11.2.2.5 || 8.6.4.19.5 Terminal Stopping Devices 8.11.2.2.6 || 8.6.4.19.6 Firefighter’s Emerg. Oper. 8.11.2.2.7 || 8.6.4.19.7 Standby/Emerg. Power Oper. 8.11.2.2.8 || 8.6.4.19.8 Door Closing Force & KE 8.11.2.2.9 || 8.6.4.19.9 Broken Rope or Tape Switch 8.11.2.2.10 || 8.6.4.19.10 E/E/PES checkout 8.11.2.2.11 || 8.6.4.19.11 ACOSP/UCM Tests (2010 >) || 8.6.4.19.12 Traction Loss Detection (2010 >) || 8.6.4.19.13 BSM & RS Detection Means cdp
7/25/12 www.CodeDataPlate.com 56
Inquiry: Are Escalators no longer required to be tagged?
Approved TN 02-3392 is what is shown in 2007 - 8.11.1.6 where did the language in a-2008 and b-2009 come from?
a-2008 b-20098.6.1.7.2 ________ A test _____ tag with the test date, the_________ requirement _ number requiring the test, and thename of the person or firm performing the test shall beinstalled inthe machine room _______ for all Category 1 and 5 tests forelectric elevators and Category 1, 3, and 5 tests forhydraulic elevators._________
8.6.1.7.2 ________ A test _____ tag with the test date, the_________ requirement _ number requiring the test, and thename of the person or firm performing the test shall beinstalled inthe machine room _______ for all Category 1 and 5 tests forelectric elevators and Category 1, 3, and 5 tests forhydraulic elevators._________
?
7/25/12 www.CodeDataPlate.com 57
7/25/12 www.CodeDataPlate.com 58
Escalators & Moving Walk – Periodic Test REQ. Tag Person or Firm Performing Test:
Test Category: 1 REQ. #<2007 || a-2008> Test Item Test Date 8.11.4.2.1 ||8.6.8.15.1 Machine Space Access 8.11.4.2.2 ||8.6.8.15.2 Machine Space Stop Switch 8.11.3.2.3 ||8.6.8.15.3 Controller and Wiring 8.11.4.2.4 ||8.6.8.15.4 Drive Machine & Brake Torque Test 8.11.4.2.5 ||8.6.8.15.5 Speed Governor 8.11.4.2.6 ||8.6.8.15.6 Broken Drive Chain Device 8.11.4.2.7 ||8.6.8.15.7 Reversal Stop Device 8.11.4.2.8 ||8.6.8.15.8 Broken Step-Chain/Treadway Device 8.11.4.2.9 ||8.6.8.15.9 Escalator Step Upthrust Device 8.11.4.2.10 ||8.6.8.15.10 Missing Step/Pallet Device 8.11.4.2.11 ||8.6.8.15.11 Step/Pallet Level Device 8.11.4.2.12 ||8.6.8.15.12 Step/Pallets, Chain and Trusses 8.11.4.2.13 ||8.6.8.15.13 Handrail Safety System Entry Device
and Speed Monitoring
8.11.4.2.14 ||8.6.8.15.14 Heaters Outdoor Units 8.11.4.2.15 ||8.6.8.15.15 Permissible Stretch of Esc. Step Chain 8.11.4.2.16 ||8.6.8.15.16 Disconnected Motor Device 8.11.4.2.17 ||8.6.8.15.17 Response to Smoke Detectors 8.11.4.2.18 ||8.6.8.15.18 Comb/Step/Pallet Impact Device 8.11.4.2.19 ||8.6.8.15.19 Esc. Step/Skirt Performance Index 8.11.4.2.20 ||8.6.8.15.20 Esc. Clr. Step and Skirt (Loaded Gap) 8.11.4.2.21 ||8.6.8.15.21 Inspection Controls 8.11.4.2.22 ||8.6.8.15.22 Esc. Step Lateral Displace Device (2010 >) || 8.6.8.15.23 Seismic Switch Operation Test
cdp
7/25/12 www.CodeDataPlate.com 59
Approved TN 02-3392 moved all test tagging requirements to 8.11.1.6 as it appears in A17.1-2007 - but
7/25/12 www.CodeDataPlate.com 60
Inquiry: Did the Releasing Carrier Tag come back in a-2008?
7/25/12 www.CodeDataPlate.com 61
7/25/12 www.CodeDataPlate.com 62
7/25/12 www.CodeDataPlate.com 63
Approved TN 02-3392 moved all test tagging requirements to 8.11.1.6 as it appears in A17.1-2007 - but
7/25/12 www.CodeDataPlate.com 64
Inquiry: Did the Buffer Test Tag come back in a-2008?
7/25/12 www.CodeDataPlate.com 65
7/25/12 www.CodeDataPlate.com 66
Approved TN 02-3392 changed several additional items (in a, b, f and h) to be tested in A17.1-2007 - but
7/25/12 www.CodeDataPlate.com 67
Inquiry: Are test of Overspeed Switch and checking for the seal no longer required in a-2008? Ref. 8.6.4.20.5 should be 8.6.4.19.5 and all 8.6.4.18 references should be 8.6.4.19!
7/25/12 www.CodeDataPlate.com 68
7/25/12 www.CodeDataPlate.com 69
Hydraulic Elevator - Periodic Test REQ. Tag Person or Firm Performing Test:
Test Category: 1 REQ. #<2007 || a-2008> Test Item Test Date 8.11.3.2.1 ||8.6.5.14.1 Relief Valve & System Pressure 8.11.3.2.2 ||8.6.5.14.2 Cylinder & Pressure Piping 8.11.3.2.3(a) ||8.6.5.14.3(a) Normal Terminal Stopping Device 8.11.3.2.3(b) ||8.6.5.14.3(b) Governors 8.11.3.2.3(c) ||8.6.5.14.3(c) Safeties 8.11.3.2.3(d) ||8.6.5.14.3(d) Oil Buffers 8.11.3.2.3(e) ||8.6.5.14.3(e) Firefighter’s Emerg. Oper. 8.11.3.2.3(f) ||8.6.5.14.3(f) Standby/Emerg. Power Oper. 8.11.3.2.3(g) ||8.6.5.14.3(g) Power Operation of Doors 8.11.3.2.3(h) ||8.6.5.14.3(h) Terminal Speed Reducing 8.11.3.2.3(i) ||8.6.5.14.3(i) Low Oil Protection 8.11.3.2.4 ||8.6.5.14.4 Flexible Hose & Fitting 8.11.3.2.5 ||8.6.5.14.5 Pressure Switch (2010 >) || 8.6.5.14.6 Power Operation of Doors (2010 >) || 8.6.5.14.7 Slack Rope Device
cdp
7/25/12 www.CodeDataPlate.com 70
Approved TN 02-3392 required only in Canada a tag to be placed on the governor after the test in A17.1-2007 - but
7/25/12 www.CodeDataPlate.com 71
Inquiry: Is the Governor Test Tag no longer required in a-2008 for jurisdictions enforcing NBCC?
7/25/12 www.CodeDataPlate.com 72
7/25/12 www.CodeDataPlate.com 73
Section 8.62007 vs. a-2008 & b-2009
Recommendation:Mark-up errors in 8.6 and
Don’t replace the pages in 8.11until an errata is published
(most errors were in moving of tests to 8.6)
2010 is correct
7/25/12 www.CodeDataPlate.com 74
Section 8.10approved forA17.1-2013
Test Tags for Acceptance Tests
75
Electric Elevator - Acceptance Test Tag – DO NOT REMOVE
Person or Firm Performing Test: Date:
Witnessed by: QEI #
REQ. # Devices Tested/ Test Results of Tests 8.10.2.2.1(h) Door Closing Force Test 8.10.2.2.1(i) Door Closing Time Test 8.10.2.2.1(j)(1) Door Opening 8.10.2.2.1(j)(2) Leveling Zone and Speed 8.10.2.2.1(j)(3) Inner Landing Zone 8.10.2.2.1(q) Emergency / Standby Power Test 8.10.2.2.2(v) Braking System Test 8.10.2.2.2(y)(3) Winding Drum Machines Slack Rope 8.10.2.2.2(y)(6) W.D. Mach. Final Terminal Stopping 8.10.2.2.2(cc)(a) Emergency Stop 8.10.2.2.2(cc)(3) Traction Limit 8.10.2.2.2(ff) Terminal Stopping Devices Test 8.10.2.2.2(hh) Governors Overspeed Test 8.10.2.2.2(ii) Car Safety Test 8.10.2.2.2(ii)(2) Car Safety Type ‘A’ inertia app. Test 8.10.2.2.2(ii) Counterweight Safety Test 8.10.2.2.2(ii)(2) Cwt Safety Type ‘A’ inertia app. Test 8.10.2.2.2(jj)(1) Ascending Car OS Protection Test 8.10.2.2.2(jj)(2) Unintended Car Movement Test 8.10.2.2.2(mm) Emergency Brake 8.10.2.2.3(d) Top Car Clearance / Refuge Space 8.10.2.2.3(ff) Unexpected Car Movem. (top-of-car) 8.10.2.2.5(c) Car Oil Buffer Test 8.10.2.2.5(c) Counterweight Oil Buffer Test 8.10.2.2.5(l) Unexpected Car Movement (pit) 8.10.2.2.6 Firefighters’ Emergency Operation cdp
76
Hydraulic Elevator Acceptance Test Tag – DO NOT REMOVE Person or Firm Performing Test: Date:
Witnessed by: QEI # REQ. # Devices Tested/ Test Results of Tests
8.10.3.2.1(h) Door Closing Force Test 8.10.3.2.1(i) Door Closing Time Test 8.10.3.2.1(j) Door Opening 8.10.3.2.1(q)(1) Emergency / Standby Power Test 8.10.3.2.1(q)(2) Auxiliary Power Lowering 8.10.3.2.2(s)(6) Phase Protection 8.10.3.2.2(s)(7) Low Oil Protection 8.10.3.2.2(t) Working Pressure Verification 8.10.3.2.2(u) Relief Valve Setting Test 8.10.3.2.2(y) Supply Line & Shutoff Valves 8.10.3.2.2(z) Hydraulic Cylinder Plunger Stop 8.10.3.2.2(aa) Press. Sw. Test (Cyl. top above tank) 8.10.3.2.2(bb) Recycle Oper. Test (Mult. or Tel.Cyl.) 8.10.3.2.2(cc) Static Controls 8.10.3.2.2(ee) Operating Devises 8.10.3.2.2(ff) Governor Overspeed 8.10.3.2.2(hh) Class C2 Freight Elevators 8.10.3.2.3(d) Top Car Clearance / Refuge Space 8.10.3.2.3(e) Normal Terminal Stopping Device 8.10.3.2.3(e) Terminal Stopping Device 8.10.3.2.3(f) Terminal Speed Reducing 8.10.3.2.3(g) Car Lev. & Anticreep Oper. Test 8.10.3.2.3(dd) Safety Inertia Application Test 8.10.3.2.3(ff) Unexpected Car Movem. (top-of-car) 8.10.3.2.5(b) Bot. Clear., Refuge Space & Runby 8.10.3.2.5(c)(3)(a) Plunger Clearance Bottom of Cyl. 8.10.3.2.5(e) Normal Terminal Stopping Device 8.10.3.2.5(j) Car Safety 8.10.3.2.5(n) Plunger Gripper Test 8.10.3.2.5(o) Overspeed Valve Test 8.10.3.2.6 Firefighters’ Emergency Operation
cdp
7/25/12 www.CodeDataPlate.com 77
Typical Data Plate Violations• A17.1-2000 and later editions Part 8
• A17.3-1996 and later editions
8.6.1.6.7 Signs and Data Plates. Required signsand data plates that are damaged or missing shall berepaired or replaced.
8.6.1.5 Code Data Plate8.6.1.5.1 A data plate that indicates the Codeand edition in effect at the time of installation and anyalteration (see 8.7.1.8) shall be provided. The data plateshall also specify the Code and edition in effect at thetime of any alteration and the applicable requirementsof 8.7.8.6.1.5.2 The Code data plate shall complywith 8.9.
3.5.6 Rail Lubricants and Lubrication Plate…A metal plate shall be securely attached to the car crosshead…
7/25/12 www.CodeDataPlate.com 78
8.6.1.6.7 Check for any Missing or Damaged Signs and Data Plates
• Machine Room– Brake Plates
– Governor Plate
– Code Data Plate
– Ambient Air Plate
– Hydro Data Plates
– Warning Signs
• Fire Service Signs
• Hoistway and Pit– Crosshead Data Plate
– Rail Lube Instructions
– Warning Signs
– Safety Plank Plate
– Buffer Plate
– Counterweight Runby
• Freight & Capacity
7/25/12 www.CodeDataPlate.com 79
● ●
POUNDS F.P.M.
NUMBER OF ROPES: IN.
MANUFACTURED: BY:
RAIL LUBRICATION INSTRUCTIONS:
● ●
RATED BREAKING STRENGTH: POUNDS
the safety for the characteristics of the rail lubricant to be used.
DIAMETER:
RATED SPEED:
COMPLETE CAR WEIGHT:
RATED LOAD:
POUNDS
CROSSHEAD DATA PLATE
codedataplate.com
INSTALLATION CODE: ASME A17.1a-1997
CODE DATA PLATE
#REF!SECT. 8.7 REQUIREMENTS COMPLIED WITH:
8.7.2.11.5, 8.7.2.28.
CODE DATA PLATEINSTALLATION CODE: ANSI A17.1-1978
ALTERATION CODE: ASME A17.1-2000
codedataplate.com
MAXIMUM COUNTERWEIGHT
RUNBY 24"
● ●
NORMAL
REDUCED
●
DOOR OPERATOR DATA PLATE
Seconds
Seconds
cdp ●
● ●
● CDP ●
LOAD RATING: 6000 POUNDS
NUMBER OF SPRINGS: 2
BUFFER MARKING PLATE
STROKE: 2 1/2 INCHES
● ●
● cdp ●
DO NOT LUBRICATE
RAIL LUBRICATION INSTRUCTIONS:
7/25/12 www.CodeDataPlate.com 80
Products
codedataplate.com
INSTALLATION CODE: ASME A17.1a-1997
CODE DATA PLATE
SECT. 8.7 REQUIREMENTS COMPLIED WITH:
CODE DATA PLATE
INSTALLATION CODE: ANSI A17.1-1971
ALTERATION CODE: ASME A17.1-2000
8.7.2.1.5, 8.7.2.8, 8.7.2.11.5, 8.7.2.12, 8.7.2.13, 8.7.2.14.3, 8.7.2.19, 8.7.2.20, 8.7.2.25.1(b), 8.7.2.27.1, 8.7.2.27.2, 8.7.2.27.5, 8.7.2.28
codedataplate.com
#REF!PART XII RULES COMPLIED WITH:
codedataplate.com
1201.11, 1202.13.
ALTERATION CODE: ASME A17.1a-1994
INSTALLATION CODE: ANSI A17.1-1978
CODE DATA PLATE
#REF!
1200.5d, 1201.3, 1201.10b, 1201.11a, 1201.12, 1202.3c, 1202.4a, 1202.5a, 1202.11, 1202.12a, 1202.12b, 1202.12e, 1202.13
codedataplate.com
1P30777
PART XII RULES COMPLIED WITH:
CODE DATA PLATE
INSTALLATION CODE: NYC BC 1938 - Article 14
ALTERATION CODE: ASME/ANSI A17.1b-1989
● ●
NORMAL
REDUCED
●
DOOR OPERATOR DATA PLATE
Seconds
Seconds
cdp ●
X
At:
X
At:
● cdp ●
Building Office
MAINTENANCE CONTROL PROGRAM LOCATION
Machine Room
LOCATION OF MAINTENANCE RECORDS
●●
Machine Room Contact:
Building Office ||
7/25/12 www.CodeDataPlate.com 81
Contact Information
office:281/257-0516cell: 832/239-2513