7745 Alarm TRX
CHANNEL FAILURE RATE ABOVE DEFINEDTHRESHOLD
-
8/12/2019 7745 Investigation Presentation
2/22
2 Nokia Siemens Networks. All righ ts reserved.
7745 - CHANNEL FAILURE RATE ABOVE DEFINEDTHRESHOLD
MeaningThe rate of calls terminating in failure on a channel is above the thresholdvalue set by the operator. The alarm is used to supervise the functioning oftraffic and signaling channels, and to detect the possible faulty channels.
Alarm in TRXlevel, reported in BSC
Category
Quality of Services Alarm, Severity Medium
KeyWord
Whenever a channel is released with a release cause other than a normal one,the counter of channel failures for the released channel is incremented.
NSN Default Threshold :
TCHFR = TCH failure rate (20 % or 30%)SCHFR = SDCCH failure rate (80 %)
PRDCFR = length of supervision period (60 min)
CS = channel seizure threshold value (10)
-
8/12/2019 7745 Investigation Presentation
3/22
3 Nokia Siemens Networks. All righ ts reserved.
7745 - CHANNEL FAILURE RATE ABOVE DEFINEDTHRESHOLD
Channel Release procedure
Whenever a channel is released with a release cause other than a normal one,
the counter of channel failures for the released channel is incremented.After a certain observation time and a certain threshold it will reported in the7745 alarm. It give an indication that theres a failure that need to beaddressed, but overall KPI need to be used as a first priority.
-
8/12/2019 7745 Investigation Presentation
4/22
4 Nokia Siemens Networks. All righ ts reserved.
7745 - CHANNEL FAILURE RATE ABOVE DEFINEDTHRESHOLD
TCH Failure
0A Channel state conflict between RRMPRB and ABIPRB
0B Channel type conflict between RRMPRB and ABIPRB
0D TCH radio failure
0E Source TCH radio failure in HO
0F Target TCH radio failure in HO
1D TCH transcoder failure
1E Source TCH transcoder failure in HO
1F Target TCH transcoder failure in HO
2E TCH failure due to a LAPD failure
2F TCH failure due to a BTS failure
30 TCH failure due to user actions
31 TCH failure due to a BCSU reset
32 TCH failure due to radio network reconfiguration actions
51 TCH activation failure during call set-up
53 Target TCH activation failure in HO
54 TCH failure due to an Abis interface failure in call set-up
55 Source TCH failure due to an Abis interface failure in HO
56 Target TCH failure due to an Abis interface failure in HO
57 TCH failure due to an A interface failure in call set-up
58 Source TCH failure due to an A interface failure in HO
59 Target TCH failure due to an A interface failure in HO
FF Actually no release cause, but causes all channels with
an abnormal release cause to be l isted
SDCCH Failure
03 SDCCH radio failure
04 Source SDCCH radio failure in HO
05 Target SDCCH radio failure in HO
0A Channel state conflict between RRMPRB and ABIPRB
0B Channel type conflict between RRMPRB and ABIPRB
23 SDCCH failure due to a LAPD failure24 SDCCH failure due to a BTS failure
25 SDCCH failure due to user actions
26 SDCCH failure due to a BCSU reset
27 SDCCH failure due to radio network reconfiguration actions
48 SDCCH activation failure during call set-up
4A Target SDCCH activation failure in HO
4B SDCCH failure due to an Abis interface failure in call set-up
4C Source SDCCH failure due to an Abis interface failure in HO
4D Target SDCCH failure due to an Abis interface failure in HO
4E SDCCH failure due to an A interface failure in call set-up
4F Source SDCCH failure due to an A interface failure in HO
50 Target SDCCH failure due to an A interface failure in HO
7745 alarm occurance in Telkomsel Network
Around 90% is affected in TCH, around 10% is affected in SDCCHAbnormal relase cause defined below :
-
8/12/2019 7745 Investigation Presentation
5/22
5 Nokia Siemens Networks. All righ ts reserved.
7745 - Alarm Information
AKSES_UI BCF-0065 BTS-0156 QUAL 2009-01-13 13:51:49.59
** ALARM TRX -006 JNCSILIWANGIMD2
DISABLED(60756) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 01 01 01 01 01 00 00 04 00 48d
AKSES_UI BCF-0065 BTS-0156 QUAL 2009-01-13 13:51:49.59
.. CANCEL TRX -007 JNCSILIWANGIMD2
ENABLED
(60755) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 00 00 00 00 00 00 0d
Supplementary information fields
1 indicates if the alarm is on the TCH or on the SDCCH channel 01: TCH 02: SDCCH
2..9 indicates if the channel failure rate is above the defined threshold in time slot 0 00:belove threshold (no alarm) 01: above threshold (alarm)
10 time slot with the highest failure rate
11 subchannel identification TCH: 00: TCH/H -subchannel 0 01: TCH/H -subchannel 1 02:TCH/F -subchannel subchannel identification SDCCH: 00 - 07: SDCCH -subchannel 0 7
12 proportion/percentage of TCH or SDCCH subchannel releases due to failure in allchannel releases on a given channel during the measurement period
-
8/12/2019 7745 Investigation Presentation
6/22
-
8/12/2019 7745 Investigation Presentation
7/22
7 Nokia Siemens Networks. All righ ts reserved.
Step By Step SummaryFlowchart for investigation methodology
-
8/12/2019 7745 Investigation Presentation
8/22
8 Nokia Siemens Networks. All righ ts reserved.
BTS installation standard
TX1,2 and RX main
TX 3,4 and RX div
-
8/12/2019 7745 Investigation Presentation
9/22
9 Nokia Siemens Networks. All righ ts reserved.
If we have 7745, 7743 alarms in our network, what is
really happening?
Before Site Visit :Make sure Audit neighbor, TSC checking and TRXtest
Action on site :1. 7745, 7743 at one TRX only
- Check SMA cable at Tx connector to WCXA of the TRX, make sure properly connected
- Replace TRX, BB2F and SMA cables if needed
2. 7745, 7743 at two TRX
- Try to switch BCCH, if still appear potential have a partial cross feeder
- Replace TRX, BB2F WCXA, or DVXA if needed
- Check alarms of other sector to ensure analysis
3. 7745, 7743 at all TRXs under same cell
- Possibilities error : full partial cross feeder, bad feeder quality and its connection,interference, broken DVXA
-
8/12/2019 7745 Investigation Presentation
10/22
10 Nokia Siemens Networks. All r ights reserved.
If we have 7745, 7604 alarms in our network, what is
really happening?
If: VSWR have been checked,
Then: We can find out from hardware by checking its transmit path from TRxunit, Tx port, SMA-cables from Tx port to WCxA, WCxA itself, and so on, untilits feeder connection and antenna.
Thus:
7604 alarm is usually related to degraded receive quality of one sector or oneTRx.
From hardware point of view:
Check its receive path from TRx unit, Rx main and RxDiv port, SMA cablesfrom Rx port to M2xA, M2xA itself, and so on, until its feeder connection andantenna.
-
8/12/2019 7745 Investigation Presentation
11/22
11 Nokia Siemens Networks. All r ights reserved.
Sample ND 196
Performance Analysis:
IF: band q5 value is under 95%
THEN: we suspect that the TRX have badquality uplink or Downlink ( in this case
downlink issue)
-
8/12/2019 7745 Investigation Presentation
12/22
12 Nokia Siemens Networks. All r ights reserved.
Sample ND 195
Base on BTS installation standard that :
Uplink and Downlink between TRX in one sectoris maks 3db
This report shows for each TRX:
Ave MS pwr attn /lb_11 Average MS power attenuation (dB)
Ave BS pwr attn /lb_12 Average BS power attenuation (dB)
Ave UL str /lb_9 Average UL signal strength
Ave DL str /lb_10 Average DL signal strength
. The signal (UL, DL) strength is given as value 0..63 (GSM 5.08)
. 0 =less than -110dBm, 1= -110 to -109 dBm, 3= -109 to -108dBm
. .. . 62 = -49 to -48, 63=greater than -48
SAMPLE ABOVE :
For Down link TX 1 and TX 2 have big differences , also for TX5and TX6 for sec 2
For Uplink RX main having 3db diff in sec 1, for sec 2 have 9 dbdiff
-
8/12/2019 7745 Investigation Presentation
13/22
13 Nokia Siemens Networks. All r ights reserved.
Sample ND 232 ( Time advance)this si te having overshoot issue
-
8/12/2019 7745 Investigation Presentation
14/22
-
8/12/2019 7745 Investigation Presentation
15/22
15 Nokia Siemens Networks. All r ights reserved.
AUDIT ANTENNA and Neighbors
-
8/12/2019 7745 Investigation Presentation
16/22
16 Nokia Siemens Networks. All r ights reserved.
Sample ND 153 ( handover)
MancagarMD3 to CiropohMG2 and cisarunimg having 100% fail MancagarMD3 to mancagar MG3 having 85 of 2144 sample call Fail
This report showing incoming and outgoing handover
-
8/12/2019 7745 Investigation Presentation
17/22
17 Nokia Siemens Networks. All r ights reserved.
Exception for 7745
7745 will keep occur for this condition :1. No have neighbors cell ( island or remote standalone)
2. Landscape contour ( hill and valley)
3. Obstacle
This exception need to be justify as long as the KPI value achieve
-
8/12/2019 7745 Investigation Presentation
18/22
-
8/12/2019 7745 Investigation Presentation
19/22
19 Nokia Siemens Networks. All r ights reserved.
RFI Site Procedure
Objective:1. To have better site integration verification procedure2. To make sure that all functionality of the integration site already
in place and being verified3. To avoid unnecessary mistake on integration such as cross feeder
(partial and full), Loose feeder and others functionalities.
Additional :
-
8/12/2019 7745 Investigation Presentation
20/22
20 Nokia Siemens Networks. All r ights reserved.
RFI Site Procedure Methodology:
There are 3 group of site check of this test call procedure:a. Connected Mode
- Mobile originated calls of voice services
b. Cross feeder Check1.Using Network Monitoring on TEMS/NEMO (for best result for recognizing cross feeder
symptom, Move along main lobe of each cell 500 m, and make sure that we have theserving CI along the main lobe).
2.Make Test Call and notate the used TRX in case of Hopping TRX eg. (Synthesizer Hopping)Specific MAIO will represent specific transceiver according to system Configuration or Siteparameter. In case of Baseband Hopping TRXs then Baseband hopping parameter shall bedisable then individual test shall be carried out individually per TRX according to Database
Site parameter.3.Lock the Transceiver carrying BCCH Frequency and perform test number 2 until all TRXs inthe same cell have been successfully verified
4.Locate the same treatment in the different sectors5.Failed TRXs can trigger further analysis with the site inspection on possible wrong
connection or swapped feeder/antennac. Hardware Inspection
- Antenna Type- Antenna azimuth
- Antenna downtilt (Mechanical/Electrical)- Have feeder label and match with antenna
d. Remarks for further finding on the field
-
8/12/2019 7745 Investigation Presentation
21/22
THINGS TO REMEMBER:
ND 195:
Average /sector range is 3-5
Number of sample preferably >1000
ND 196:
Focus result at q5, q6 and q7
UL and DL percentage should be 95
ND 232:
Range (km)
Area (rural or urban)
Number of report (samples)
ND 153:
To fail = 0
-