8 7 6 5 4 3 2 1 dwg no ---- model release a dwg ...a 2 c do not scale drawing d part no c dwg no 1...
TRANSCRIPT
REV
2 REF:
ALL DIMENSIONS ARE IN MILLIMETERS
8
PROJECTION
7
3
SHEET
4
REVISION RECORD
FIRST USEDM.E.
C
B
TITLE:
OFPART NO
6
A
1
CHKR
DO NOT SCALE DRAWING
ONE-PLACE (X.X)
C
DATE
3
DFTR-ORIG
2
THIRD ANGLE
D
REV
4
D
7
REV
DWGNO
DFTR
1
MATERIAL:
DSNR
WHOLE DIM (X)
P.E.
R
ORIG. DATE
B
DATE
UNSPECIFIED TOLERANCES ARE:
COPYRIGHT 2012WINNEBAGO
INDUSTRIES, INC.
TWO-PLACE (X.XX)
5
ZONE
A
ANGLE
6 5
8
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
A
13 231J
1.5
0.50
1
1 3
3
181550
DRAINAGE SYSTEM INSTL
RELEASE ----DWG NO
SECTION F-F181550-01
181550-02
SECTION B-B
181550
B&F(SEE TAB)
B&F(SEE TAB)
MODEL
231JP
231J
43E TOILET PROCELAIN-ROUND
464 TOILET
1B1 CODES/STANDARDS USA
265 CODES/STANDARDS-CSA/CMVSS
23T DRAINAGE SYSTEM-HEATED
644 GREAT ALASKAN RENTALS
A
CALLOUTSSEE DWG NO
116229-01-000
FORDRAINAGE
NOTES:
X-X
12 SEE WIRING INSTL-BODY FOR ELECTRICAL CONNECTION.
11 PREP THE SURFACE PER MANUFACTURERS INSTRUCTIONS BEFORE APPLYING THE HEATING PAD.
10 WATERLESS P-TRAP MUST BE INSTALLED WITH THE RIBS POINTING DOWN
9. SEE DRAWING 061607 FOR INSTALLATION OF GROMMETS.
8. SECURE DRAINAGE PIPES TO CABINET USING WIRE TIE 108046-02-000, AND SCREW 000G67-10-12U AT INTERVALS OF NOT OF NOT MORE THAN 4 FEET APART.
7 SECURE VENT PIPE TO FLOOR WITH CLAMP 062401-02-000 (2),SCREW 000G67-10-12U (2), BRACKET 136878-01-CHT (2).
6 VENT PIPE MUST PROJECT 51 MIN AND 64 MAX ABOVE ROOF FOR PROPER FIT AND FUNCTION. ADD S-1 (116666-01-CHT SEAL-VENT PIPE) AROUND PIPE ON ROOF BEFORE VENT CAP IS INSTALLED.
5. SEAL AROUND SHOWER WITH SILICONE.
4 USE SMOOTH PLUMBERS PUTTY 167459-01-000 TO SEAL STRAINER (0.2 PER STRAINER).
3. ALL PIPE AND FITTINGS TO BE ASSEMBLED WITH SOLVENT 004020-01-000 (USA), 004020-02-000 (CAN)
2. SLOPE OF TRAP ARM MUST BE 6 PER 305 mm.
1. SLOPE OF HORIZONTAL PIPING TO BE MINIMUM OF 3 PER 305 mm.
13-Jun-2012
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
13 231J
2
181550
DRAINAGE SYSTEM INSTL
181550 SECTION B-B
(SHOWN W/OUT FLOOR)
VIEW A
DETAIL C(SHOWN W/OUT SHOWER AND CABINETS)
DETAIL C
DETAIL D(SHOWN W/OUT FLOOR AND CABINETS)
DETAIL D
265
P-1
1B1
4
P-3
A-15
W-2
1B1
SINK179864-01-CHTSTRAINER092303-01-000 (2)SEAL091255-03-000(2130)
1B1
1250
VM-1
265
T-1
11701B1
T-1
P-3
1B1P-1
265
1415
VM-1
1B11
80
A-15
265 1175
464
43ETOILET160815-01-CHTSCREW087721-01-000(8)
644
TOILET147421-04-CHTTOILET-STYLE II W/O SPRAYER160815-03-CHTSCREW087721-01-000 (6)
E-61
325
T-4
N-3
1285
TRAP-WATERLESS165406-01-000
ADAPTER165406-02-000
STRAINER066440-01-000
1250
PIPE-STAND130234-02-000
10
A-15
G-2
F-6
G-2
N-3
F-6
SHOWER INSTL-ENCLOSURE164684-07-000
SINK-LAVATORY096927-01-CHTSEAL091255-02-000 (A/R)
SECTION F-F(SHOWN W/OUT FLOOR)
185
1485
1350
7
155
G-1
E-1
T-11
560
E-1
E-1
1250
145
1100
Y-1
1840
1785
150E-1
T-4
1775
6CP-2
E-5
C-3
155
7 G-1
13-Jun-2012
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
13 231J
3
181550
DRAINAGE SYSTEM INSTL
181550
12
CRADLE ASM139597-03-CHTWASHER000E13-16-00U(4)NUT000D39-05-00U(4)
TANK-HOLDING139645-08-CHT
CRADLE ASM139596-05-CHTWASHER000E13-16-00U(4)NUT000D39-05-00U(4)
TANK-HOLDING139646-11-CHT
VIEW E
47
2751498
1222
4778
5229
N-3H-2
260
V-11 260 C-2
644C-2
N-3
E
11
12
23T
23T
11PAD-HEATER133972-04-000INSTALL PER MANUFACTURERS LABEL
PAD-HEATER133972-04-000INSTALL PER MANUFACTURERS LABEL
13-Jun-2012
REV
2 REF:
ALL DIMENSIONS ARE IN MILLIMETERS
8
PROJECTION
7
3
SHEET
4
REVISION RECORD
FIRST USEDM.E.
C
B
TITLE:
OFPART NO
6
A
1
CHKR
DO NOT SCALE DRAWING
ONE-PLACE (X.X)
C
DATE
3
DFTR-ORIG
2
THIRD ANGLE
D
REV
4
D
7
REV
DWGNO
DFTR
1
MATERIAL:
DSNR
WHOLE DIM (X)
P.E.
R
ORIG. DATE
B
DATE
UNSPECIFIED TOLERANCES ARE:
COPYRIGHT 2012WINNEBAGO
INDUSTRIES, INC.
TWO-PLACE (X.XX)
5
ZONE
A
ANGLE
6 5
8
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
A
13 231J
1.5
0.50
1
1 3
3
181549
WATER SYSTEM INSTL
RELEASE DWG NO
181549-01
NOTES:
181549-02
181549
64R
GREAT ALASKAN RENTAL PACKAGE
WATER SYS WINTERIZATION PKG
WATER HEATER-ELEC. IGNITION
EXTERIOR WASH STATION
WTR HTR-6GAL/110/LP/MTR/AUTO
644
EXT WASH STATION - WITHOUT
53Z
1J4
53F
53E
BA
BB
CA
231JP
CC, BDCB, BE
VIEW
231J
MODEL
CALLOUTSSEE DWG NO
116230-01-000
FORWATER
NOTES:
8. ALL CRIMP FITTINGS TO 1/2" PEX TUBING REQUIRE 1/2" CLAMP 140171-03-000.
7. ALL CRIMP FITTINGS TO 5/8" PEX TUBING REQUIRE 5/8" CLAMP 140171-04-000.
6. LABEL HOT AND COLD SUPPLY TUBES AND TAPE FITTING TO TUBE BEFORE CABINET SET TO PREVENT MOVEMENT.
5. ADD PIPE WRAP (LADDER SCRAP 110157-02-000) INSULATION.
4. ADD TEFLON TAPE 010405-02-000.
3. ALL TUBING TO BE SECURED AT 1200 INTERVALS MAXIMUM WITH CLAMP 010495-01-000 AND SCREW 000G67-10-12U OR EQUIVALENT.
2. TUBING TO BE INSTALLED WITH SUFFICIENT SLOPE TO PROVIDE DRAINAGE TO NEAREST VALVE.
1. PLASTIC FITTINGS TO BE SEALED WITH SEALANT 084456-01-000.X-X
13-Jun-2012
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
13 231J
2
181549
WATER SYSTEM INSTL
181549
VIEW BA
DETAIL BC
DETAIL BC
VIEW BB(SHOWN W/OUT COVER-PIPE)
VIEW BB(SHOWN W/OUT COVER-PIPE &
COMPT ASM-SHOWER,EXT)
FAUCET-LAVATORY148886-03-CHTFAUCET-LAVATORY165730-01-CHT644
6
64R
TU-9120
6
TU-9270
TU10120
TU10400
TU-990
TU-9790
TU-9300
1J4
1J4
1J4
F-13
TU-81200
6DETAIL BD
DETAIL BD & BE(SEE TAB)
FAUCET-LAVATORY165730-01-CHT
DETAIL BE
TU-9150
1J4
TU-960
V-10
TU-980
V-10
TU1060
TU1070 6
TU-9100
TU10100
CA-3
PANEL-SHOWER167738-02-CHTSCREW000G11-08-12U (4)COVER166569-01-CHT (4)NUT-SPEED-U040921-05-000 (4)
F-2
SH-1
TU-92450
TU102450
S-1 2
TU-91265
TU101520
COVER-PIPE176868-01-CHT
TU-9720
E-442
F-4
F-5
TU-9225
R-4R-4
R-4R-4
T-29
E-44
E-44
T-29
T-29
E-46
E-46
A-28
T-28
E-43
T-28
E-43
COVER-WATER LINE179288-01-CHT
A-28
A-28
E-44
T-29
E-43T-29
13-Jun-2012
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
13 231J
3
181549
WATER SYSTEM INSTL
181549
F-9
53Z
53F
VIEW CA
R-9
DETAIL CC
DETAIL CC(SEE TAB)
DETAIL CC644
TU-940
FAUCET-GALLEY149164-01-CHT
TU1040
TU-9100
A-26
CLAMP010495-01-000SCREW000G67-10-12U
A-28
TU-9130
V-6
4
TU-995
4
56050
TU10130
V-6
DETAIL CD
DETAIL CDDETAIL CB
FILTER160946-03-000SCREW000G67-10-12U (2)
T-28
TU1040
TU-9745
TU-960
TANK ASM156167-08-000STRAP118994-10-CHT(2)WASHER000E13-16-00U(4)NUT000D39-05-00U(4)ELEVATOR BOLT000C18-05-40U(4)
TU1040
TU-995
TU-960
TU-975
DETAIL CE
DETAIL CE
53E
VALVE132483-01-000ELBOW132782-01-000TUBE074462-01-000(100MM)
TU-8385
CH-2
TU-31000
CI-3
A-5
53E
53E
A-5CH-2 A-17
53E
53E 53E 53E
TU-8440
V-11
53E
PW-5
WATER HEATER051391-03-000145541-02-000DOOR125420-06-CHTAL EXTR002726-01-210(2)002726-01-212(2)SCREW000G39-10-169(18)SEALANT069640-14-000CABLE076767-03-000
CH-12
CH-1
A-4A-5CH-22
TU10200
TU-41800
TU-31855
A-26FAUCET-GALLEY149164-01-CHT
TU10130
TU-945
53E
A-28
E-44
E-44V-11
E-43
T-28
T-28
E-44
R-2
A-26
E-43
T-28
T-29
T-29
FAUCET-GALLEY140117-03-CHT
E-43
E-44
A-26
T-28E-43
A-27
E-43
E-43
E-44
E-44
CU-2
13-Jun-2012