8 7 6 5 4 3 2 1 - kohler co.resources.kohler.com/power/kohler/industrial/pdf/adv8514.pdf · metric...

7
A 1 2 3 4 5 6 7 8 B C D 1 2 3 4 5 6 7 8 A B C D TITLE SCALE DWG NO. CAD NO. SHEET DRAWN CHECKED APPROVED MAX. THIRD ANGLE PROJECTION POWER SYSTEMS, KOHLER, WI 53044 U .S.A. THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO. PROPERTY AND MUST NOT BE USED EXCEPT IN CONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OF DESIGN OR INVENTION ARE RESERVED. 4936.7 194.36 [ ] 117 4.6 [ ] OPENING W/DOORS REMOVED 1800 70.9 [ ] 571 22.5 [ ] A 2181 85.9 [ ] 142 5.6 [ ] OPENING W/DOORS REMOVED 1283 50.5 [ ] B 1465 57.7 [ ] REF 860 33.8 [ ] 369 14.5 [ ] 3197 125.9 [ ] OPENING W/DOORS REMOVED 899 35.4 [ ] OUTLET SILENCER 153 6.0 [ ] 260 10.2 [ ] 858 33.8 [ ] 1424 56.0 [ ] PRO-E METRIC DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK 0.05 1 of 7 ADV-8514 D UNLESS OTHERWISE SPECIFIED - 1) DIMENSIONS ARE IN MILLIMETERS 2) TOLERANCES ARE: X.XX # 0.25 X.X # 1.0 X # 1.5 SURFACE FINISH ANGLES # 0 $ 30' APPROVALS DATE KNN 10-25-12 PKD 10-25-12 AJD 10-25-12 REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY - 10-25-12 NEW DRAWING [CT28128] KNN A 10-10-13 SEE SHEET 7 [CT59787] SVP B 06-09-14 (A-8) 1333 & 1523 GAL TANKS: HOURS AND GENSET INFO UPDATED [CT83640] NMD C 2-3-17 SEE SHEET 7 [CT170345] PAS NOTES: FOR PROPER ASSEMBLY METHOD OF HARDWARE, USE G-585 AS A GUIDELINE. 350-500KW REOZJB STEEL & ALUMINUM ENCL. 12-48 HR SL1/WEATHER 1778.0 X 500.4 [70.0 X 19.7] FIXED AIR INTAKE LOUVER (STANDARD) (RIGHT & LEFT SIDE) 350-500 REOZJB KG [LBS] STEEL WEATHER ENCLOSURE WEIGHT 916 [2020] ALUM. WEATHER ENCLOSURE WEIGHT 535 [1180] STEEL SOUND L1 ENCLOSURE WEIGHT 952 [2100] ALUM. SOUND L1 ENCLOSURE WEIGHT 575 [1260] TANK INFORMATION LITERS [GALLONS] MIN HOURS GENSETS DIM A MM [INCH] DIM B MM [INCH] TANK WEIGHT KG [LBS] (NO FUEL) 1530 [404] 12 HOURS 350-400KW 406.4 [16.0] 4938.2 [194.4] 1110 [2446] 1771 [468] 12 HOURS 500KW 457.2 [18.0] 4938.2 [194.4] 1158 [2554] 2930 [774] 24 HOURS 350-400KW 762.0 [30.0] 4938.2 [194.4] 1401 [3089] 3384 [894] 24 HOURS 500KW 838.2 [33.0] 4938.2 [194.4] 1484 [3271] 4394 [1161] 36 HOURS 350-400KW 914.4 [36.0] 5637.2 [221.9] 1789 [3945] 5046 [1333] 48/36 HOURS 350/500KW 6272.2 [246.9] 1982 [4370] 5765 [1523] 48 HOURS 400KW 6983.4 [274.9] 2228 [4911] 6674 [1763] 48 HOURS 500KW 7847.0 [308.9] 2524 [5565] 1530 [404] 12 HOURS STATE 350-400KW 381.0 [15.0] 5891.2 [231.9] 1281 [2825] 1771 [468] 12 HOURS STATE 500KW 431.8 [17.0] 5891.2 [231.9] 1326 [2923] 2930 [774] 24 HOURS STATE 350-400KW 660.4 [26.0] 5891.2 [231.9] 1547 [3411] 3384 [894] 24 HOURS STATE 500KW 736.6 [29.0] 5891.2 [231.9] 1630 [3594] 4394 [1161] 36 HOURS STATE 350-400KW 914.4 [36.0] 6069.0 [238.9] 1874 [4072] 5046 [1333] 48/36 HOURS STATE 350/500KW 6831.0 [268.9] 2094 [4616] 5765 [1523] 48 HOURS STATE 400KW 7669.2 [301.9] 2329 [5134] 6674 [1763] 48 HOURS STATE 500KW 8710.6 [342.9] 2656 [5855]

Upload: vanthuan

Post on 28-Jul-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

4936.7194.36[ ]

1174.6[ ] OPENING W/DOORS

REMOVED

1800 70.9[ ] 57122.5[ ]

A

2181

85.9

[]

142 5.6

[]

OPENING W/DOORS

REMOVED

1283

50.5

[]

B

1465 57.7[ ]

REF86033.8[ ]

369 14.5

[]

3197

125.9

[]

OPENING W/DOORS REMOVED

899 35.4[ ]

OUTLET SILENCER153 6.0[ ]

260 10.2

[]

858 33.8

[]

1424 56.0[ ]

PRO-EMETRIC

DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK

0.05 1 of 7

ADV-8514 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

KNN

10-25-12

PKD 10-25-12

AJD 10-25-12

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

- 10-25-12 NEW DRAWING [CT28128] KNN

A 10-10-13 SEE SHEET 7 [CT59787] SVP

B 06-09-14 (A-8) 1333 & 1523 GAL TANKS: HOURS AND GENSET INFO

UPDATED [CT83640] NMD

C 2-3-17 SEE SHEET 7 [CT170345] PAS

NOTES: FOR PROPER ASSEMBLY METHOD OF HARDWARE,USE G-585 AS A GUIDELINE.

350-500KW REOZJBSTEEL & ALUMINUM ENCL.

12-48 HR SL1/WEATHER

1778.0 X 500.4[70.0 X 19.7]

FIXED AIR INTAKELOUVER (STANDARD)

(RIGHT & LEFT SIDE)

350-500 REOZJB KG [LBS]

STEEL WEATHER ENCLOSURE WEIGHT 916 [2020]

ALUM. WEATHER ENCLOSURE WEIGHT 535 [1180]

STEEL SOUND L1 ENCLOSURE WEIGHT 952 [2100]

ALUM. SOUND L1 ENCLOSURE WEIGHT 575 [1260]

TANK INFORMATION

LITERS [GALLONS] MIN HOURS GENSETS DIM A MM [INCH] DIM B MM [INCH] TANK WEIGHT KG [LBS] (NO FUEL)

1530 [404] 12 HOURS 350-400KW 406.4 [16.0] 4938.2 [194.4] 1110 [2446]

1771 [468] 12 HOURS 500KW 457.2 [18.0] 4938.2 [194.4] 1158 [2554]

2930 [774] 24 HOURS 350-400KW 762.0 [30.0] 4938.2 [194.4] 1401 [3089]

3384 [894] 24 HOURS 500KW 838.2 [33.0] 4938.2 [194.4] 1484 [3271]

4394 [1161] 36 HOURS 350-400KW

914.4 [36.0]

5637.2 [221.9] 1789 [3945]

5046 [1333] 48/36 HOURS 350/500KW 6272.2 [246.9] 1982 [4370]

5765 [1523] 48 HOURS 400KW 6983.4 [274.9] 2228 [4911]

6674 [1763] 48 HOURS 500KW 7847.0 [308.9] 2524 [5565]

1530 [404] 12 HOURS STATE 350-400KW 381.0 [15.0] 5891.2 [231.9] 1281 [2825]

1771 [468] 12 HOURS STATE 500KW 431.8 [17.0] 5891.2 [231.9] 1326 [2923]

2930 [774] 24 HOURS STATE 350-400KW 660.4 [26.0] 5891.2 [231.9] 1547 [3411]

3384 [894] 24 HOURS STATE 500KW 736.6 [29.0] 5891.2 [231.9] 1630 [3594]

4394 [1161] 36 HOURS STATE 350-400KW

914.4 [36.0]

6069.0 [238.9] 1874 [4072]

5046 [1333] 48/36 HOURS STATE 350/500KW 6831.0 [268.9] 2094 [4616]

5765 [1523] 48 HOURS STATE 400KW 7669.2 [301.9] 2329 [5134]

6674 [1763] 48 HOURS STATE 500KW 8710.6 [342.9] 2656 [5855]

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

OPENING W/DOORS

REMOVED

1283

50.5

[]

102540.4[ ] OPENING W/DOORS

REMOVED

1800 70.9[ ] 57122.5[ ] OPENING W/DOORS

REMOVED

899 35.4[ ]

A2344

92.3

[]

142 5.6

[]

B

4937 194.4[ ]

2591 102.0[ ]

1465 57.7[ ]

159 6.3

[]

3197

125.9

[]

2238 88.1[ ]

81632.1[ ]

1663

65.5

[]

1103

43.4

[]

263 10.4

[]

858 33.8

[]

PRO-EMETRIC

DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK

0.05 2 of 7

ADV-8514 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

KNN

10-25-12

PKD 10-25-12

AJD 10-25-12

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

- 10-25-12 NEW DRAWING [CT28128] KNN

A 10-10-13 SEE SHEET 7 [CT59787] SVP

B 06-09-14 SEE SHEET 1,5 & 6 [CT83640] NMD

C 2-3-17 SEE SHEET 7 [CT170345] PAS

350-500KW REOZJBSTEEL & ALUMINUM ENCL.

72 HR SL1/WEATHER

1778.0 X 500.4[70.0 X 19.7]

FIXED AIR INTAKELOUVER (STANDARD)

(RIGHT & LEFT SIDE)

TANK INFORMATIONLITERS [GALLONS] MIN HOURS GENSETS DIM A MM [INCH] DIM B MM [INCH] TANK WEIGHT KG [LBS] (NO FUEL)10009 [2644] 72 HOURS STATE 350-500KW 914.4 [36.0] 7264.4 [286.0] 3582 [7898]

350-500 REOZJB KG [LBS]

STEEL WEATHER ENCLOSURE WEIGHT 916 [2020]

ALUM. WEATHER ENCLOSURE WEIGHT 535 [1180]

STEEL SOUND L1 ENCLOSURE WEIGHT 952 [2100]

ALUM. SOUND L1 ENCLOSURE WEIGHT 575 [1260]

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

PRO-EMETRIC

DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK

0.05 3 of 7

ADV-8514 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

KNN

10-25-12

PKD 10-25-12

AJD 10-25-12

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

- 10-25-12 NEW DRAWING [CT28128] KNN

A 10-10-13 SEE SHEET 7 [CT59787] SVP

B 06-09-14 SEE SHEET 1,5 & 6 [CT83640] NMD

C 2-3-17 SEE SHEET 7 [CT170345] PAS

BATTERY CHARGER (LEFT SIDE)3 WAY SWITCH

W/GFI(LEFT SIDE)

1778.0 X 500.4[70.0 X 19.7]

FIXED AIR INTAKELOUVER (STANDARD)

(RIGHT & LEFT SIDE)

DISTRIBUTION PANEL (LEFT SIDE)

DC LIGHT (QTY 2)

INCANDESCENT LIGHT (QTY 2) RAIN CAP

TIMER FORDC LIGHT

OPTIONAL DISCHARGE DAMPER (MOUNTED INSIDE DISCHARGE PLENUM)

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

4936 194.3[ ]

1425 56.1[ ]

1921

75.6

[]

142 5.6

[]117

4.6[ ] OPENING W/DOORS REMOVED

1800 70.9[ ] 57122.5[ ] OPENING W/DOORS

REMOVED

899 35.4[ ]

260 10.2

[]

OPENING W/DOORS

REMOVED

1283

50.5

[]

3185

125.4

[]

86033.8[ ]

368 14.5

[]

REF146257.6[ ]

1335 52.5[ ]

1546 60.9[ ]

2697 106.2[ ]

4860 191.3[ ]

1345.3[ ]

934 36.8[ ]

3635 143.1[ ]

858 33.8

[]

PRO-EMETRIC

DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK

0.40 4 of 7

ADV-8514 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

KNN

10-26-12

PKD 10-26-12

AJD 10-26-12

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

- 10-26-12 NEW DRAWING [CT28128] KNN

A 10-10-13 SEE SHEET 7 [CT59787] SVP

B 06-09-14 SEE SHEET 1,5 & 6 [CT83640] NMD

C 2-3-17 SEE SHEET 7 [CT170345] PAS

350-500KW REOZJBSTEEL & ALUMINUM ENCL.

SL1/WEATHER

1778.0 X 500.4[70.0 X 19.7]

FIXED AIR INTAKELOUVER (STANDARD)

(RIGHT & LEFT SIDE)

12X �n�25.4

350-500 REOZJB KG [LBS]

STEEL WEATHER ENCLOSURE WEIGHT 916 [2020]

ALUM. WEATHER ENCLOSURE WEIGHT 535 [1180]

STEEL SOUND L1 ENCLOSURE WEIGHT 952 [2100]

ALUM. SOUND L1 ENCLOSURE WEIGHT 575 [1260]

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

1334.6

52.54

[]

45 1.8

[]

1425

56.1

[]

BOTTOM FLANGE TYP.25.4 1.00[ ]

R S T U V W

482 19.0

[]

342 13.5

[]

1817.1[ ]

72628.6[ ]

X Y Z ZA

B

PRO-EMETRIC

DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK

0.08 5 of 7

ADV-8514 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

KNN

10-25-12

PKD 10-25-12

AJD 10-25-12

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

- 10-25-12 NEW DRAWING [CT28128] KNN

A 10-10-13 SEE SHEET 7 [CT59787] SVP

B 06-09-14 (D-8) 1333 & 1523 GAL TANKS: HOURS AND

GENSET INFO UPDATED [CT83640] NMD

C 2-3-17 SEE SHEET 7 [CT170345] PAS

12 - 48 HOUR350-500kW STD TANK

SL1/WEATHER

1531 [404GAL.] 12 HOUR TANK SHOWN.

12

3

4

56

7 1

CONDUIT ENTRYAREA

ITEM DESCRIPTION

1 CAP, EMERGENCY VENT

2 FILL CAP, 2" LOCKABLE W/PIPE RISER

3 GAUGE, FUEL LEVEL, W/ SENDER

4 SUPPLY, FUEL (1/2" NPT)

5 RETURN, FUEL (1/2" NPT)

6 VENT, NORMAL

7 SWITCH, FUEL IN BASIN

TABLE INFORMATION

LITERS [GALLONS] MIN HOURS GENSETS B R S T U V W X Y Z ZA

1530 [404] 12 HOURS 350-400KW 4938.2 [194.4]

83.1[3.27]

1217.6[47.94]

937.9[36.93]

482.6[19.00]

668.6[26.32]

931.5[36.67]

523.9 [20.63]1771 [468] 12 HOURS 500KW 4938.2 [194.4]

2930 [774] 24 HOURS 350-400KW 4938.2 [194.4]

3384 [894] 24 HOURS 500KW 4938.2 [194.4]

4394 [1161] 36 HOURS 350-400KW 5637.2 [221.9] 574.6 [22.62] 648.3 [25.52]

5046 [1333] 48/36 HOURS 350/500KW 6272.2 [246.9] 704.3 [27.73] 577.0 [22.72] 576.6 [22.70]

5765 [1523] 48 HOURS 400KW 6983.4 [274.9] 684.3 [26.94] 591.3 [23.28] 588.9 [23.19] 704.6 [27.74]

6674 [1763] 48 HOURS 500KW 7847.0 [308.9] 704.3 [27.73] 891.3 [35.09] 868.9 [34.21] 968.2 [38.12]

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.NMD

P Q R S

1334.6

52.54

[]

T U V

45 1.8

[]

1425

56.1

[]

BOTTOM FLANGE TYP.25.4 1.00[ ]

482.0

18.98

[]

342.0

13.46

[]

180.87.12[ ]

726.028.58[ ]

W X Y Z

B

PRO-EMETRIC

DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK

0.40 6 of 7

ADV-8514 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

KNN

10-25-12

PKD 10-25-12

AJD 10-25-12

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

- 10-25-12 NEW DRAWING [CT28128] KNN

A 10-10-13 SEE SHEET 7 [CT59787] SVP

B 06-09-14 (D-8) 1333 & 1523 GAL TANKS: HOURS AND GENSET

INFO UPDATED [CT83640]

C 2-3-17 SEE SHEET 7 [CT170345] PAS

12 - 48 HOUR350-500kW STATE TANK

SL1/WEATHER

1531 [404 GAL.] 12 HOUR TANK SHOWN.

GROUND CLEARANCE I-BEAM MOUNTING HOLE ONLY

2

3 5

711

64

8

9 10

11

CONDUIT ENTRY AREA

9

ITEM DESCRIPTION

1 CAP, EMERGENCY VENT

2 PLUG, PIPE (2" NPT)

3 GAUGE, FUEL LEVEL, W/ SENDER

4 SUPPLY, FUEL (1/2" NPT)

5 RETURN, FUEL (1/2" NPT)

6 GAUGE, FUEL LEVEL, DIRECT READ

7 VENT, NORMAL

8 SWITCH, FUEL IN BASIN TOP MTD, 2"

9 PLUG, PIPE (2"NPT)

10 PLUG, PIPE (1/2"NPTF)

11 FILL CAP, 2" LOCKABLE W/PIPE RISER

INFORMATION TABLE

LITERS [GALLONS] MIN HOURS GENSETS B P Q R S T U V W X Y Z

1530 [404] 12 HOURS STATE 350-400KW 5891.2 [231.9]

83.1[3.27]

1217.6[47.94]

937.9[36.93]

482.6[19.00]

668.6[26.32]

931.5[36.67]

664.2 [26.15] 812.7 [32.00]1771 [468] 12 HOURS STATE 500KW 5891.2 [231.9]

2930 [774] 24 HOURS STATE 350-400KW 5891.2 [231.9]

704.3 [27.73]

772.6 [30.42]

3385 [894] 24 HOURS STATE 500KW 5891.2 [231.9] 772.6 [30.42]

4395 [1161] 36 HOURS STATE 350-400KW 6069.0 [238.9] 950.4 [37.42]

5046 [1333] 48/36 HOURS STATE 350/500KW 6831.0 [268.9] 891.3 [35.09] 821.1 [32.33]

5765 [1523] 48 HOURS STATE 400KW 7669.2 [301.9] 891.3 [35.09] 868.9 [34.21] 790.4 [31.12]

6674 [1763] 48 HOURS STATE 500KW 8710.6 [342.9] 891.3 [35.09] 868.9 [34.21] 1084.3 [42.69] 747.5 [29.43]

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

P Q R S T U V W X

38.1

1.50

[]

2514.6

99.00

[]

2590.8

102.00

[]

914.4

36.00

[]

GENSET MOUNTING

1076.5

42.38

[]

1065.1

41.93

[]

342.0

13.46

[]

1089.042.87[ ]

719.428.32[ ]

B

C

D

E

PRO-EMETRIC

DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK

0.40 7 of 7

ADV-8514 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

KNN

10-25-12

PKD 10-25-12

AJD 10-25-12

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

- 10-25-12 NEW DRAWING [CT28128] KNN

A 10-10-13 (D-7,D-6,D-5) DIM. C, D & E ADDED; (A-8) TANK

INFORMATION TABLE UPDATED [CT59787] SVP

B 06-09-14 SEE SHEET 1,5 & 6 [CT83640] NMD

C 2-3-17 VIEWS UPDATED FOR LIFTING PLATES [CT170345] PAS

72 HOUR350-500kW STATE TANK

SL1/WEATHER

STATE TANK

2

3 5

7

1

6

4

8

9

9

10

1

CONDUIT ENTRYAREA

ITEM DESCRIPTION

1 CAP, EMERGENCY VENT

2 PLUG, PIPE (2" NPT)

3 GAUGE, FUEL LEVEL, W/ SENDER

4 SUPPLY, FUEL (1/2" NPT)

5 RETURN, FUEL (1/2" NPT)

6 GAUGE, FUEL LEVEL, DIRECT READ

7 VENT, NORMAL

8 SWITCH, FUEL IN BASIN TOP MTD, 2"

9 PLUG, PIPE (2" NPT)

10 FILL CAP, 2" LOCKABLE W/PIPE RISER

TANK INFORMATIONLITERS [GALLONS] MIN HOURS GENSETS B C D E P Q R S T U V W X

10009 [2644] 72 HOURS STATE350-400KW 7264.4

[286.0]1595.1[62.8]

5542.3[218.2]

6624.3[260.8]

461.6[18.2]

520.9[20.5]

1224.5[48.2]

804.0[31.7]

778.5[30.7]

638.1[25.1]

570.2[22.5]

1067.2[42.0]

1097.9[43.2]500KW