    PCUSN Preventive Maintenance

    2005

  • 8/3/2019 9_PCUSN PMA

    2/18

    2

  • 8/3/2019 9_PCUSN PMA

    3/18

    3

  • 8/3/2019 9_PCUSN PMA

    4/18

    4

    PCUSN Preventive Maintenance

    PCUSN preventive maintenance procedures:Preventive maintenance

    The implementation of the preventive maintenance procedures is the responsibility ofeach customer.

  • 8/3/2019 9_PCUSN PMA

    5/18

    5

    Nortel Recommended Methods of Scheduling ofPreventive Maintenance for PCUSNIncluded in NTP 411-9001-091

  • 8/3/2019 9_PCUSN PMA

    6/18

    6

    SPM Operation Status check

    > STEP 1: Log into the PCUSN

    > STEP 2: Use the command: d lp/* pcusp pm/*

    > STEP 3: Display all the spm, which are linked to an active Agprs,make sure they are enabled.

    Use the command: d pcusa/* conn/* pcmlk/*

    > STEP 4: Procedure completed

  • 8/3/2019 9_PCUSN PMA

    7/187

    Standby Card Status

    > STEP 1: Log into the PCUSN

    > STEP 2: For each lp (Lp/0, Lp/1, Lp/5 (and Lp/8 for PCUSN24 aswell), check that you have either mainCardStatus andSpareCardStatus and either active or available.

    Use the command: d lp/*

    Example:

    mainCardStatus and spareCardStatus either active or available.

    > STEP 3 : Procedure Completed

  • 8/3/2019 9_PCUSN PMA

    8/188

    CP Synch-Status

    > STEP 1: Log into the PCUSN

    > STEP 2: For each PCUSN, check that the SyncStatus is synchronized (with the CPspare card) and

    syncProgress is equal to 100%.

    Use the command: d fs

    > STEP 3: Use the command: d ns/*

    This command will display the network synchronization

    Expected result:NS

    adminState = unlocked

    operationalState = enabled

    usageState = busy

    clockSyncState = synchronized

    activeReference = Lp/5 DS3/0 DS1/1 (AGPRS link used to get the synchronization)

    standbyReference = Lp/5 DS3/0 DS1/5 (AGPRS link used to get the synchronization)

    Ok

    > STEP 4: Procedure Completed

  • 8/3/2019 9_PCUSN PMA

    9/189

    OAM Synchronization

    Check PCUSN Time

    > STEP 1: Log into PCUSN

    > STEP 2: For each PCUSN, check that the time of the PCUSN issynchronized with the time of the

    PCUOAM workstation. This is just OAM time synchronization and not atall of the system clock synchronization.

    Use the command: d time

    > STEP 3: Procedure Completed

  • 8/3/2019 9_PCUSN PMA

    10/18

    10

    PCUSN CP Card Cleaning

    > STEP 1: Check to see if the disk usage is over 70%. If so, it is necessary to clean up thePCUSN CP card and delete all the useless view & software files: check the file systemdisk usage.

    Use the command: d fs

    > STEP 2: If the usage is more than 70%, delete some view and software files. List thesoftware that can be deleted.

    Use the command: tidyq sw> STEP 3: Choose and clean the old module.

    Use the command: remove sw av/software_module (ex:wirelessPcu_CA0335AE)

    > STEP 4: Choose and clean the old views. To list the views,

    Use the command: d pr view/*

    > STEP 5: To delete the views.

    Use the command: tidyremove(view_name) pr

    > STEP 6 : Procedure Completed

  • 8/3/2019 9_PCUSN PMA

    11/18

    11

    NMSUSER Rights checking

    > STEP 1: Check the rights of the nmsuser.

    Use the command: dp ac userid/NMSUSER

    Correct results:AllowedAccess = local telnet fmip ftp

    AllowedOutAccess = telnet

    > STEP 2 : Procedure Completed

  • 8/3/2019 9_PCUSN PMA

    12/18

    12

    Passport Bus Status and testBUS Status

    > STEP 1: Check that the two PCUSN passport buses are active and enabled. If not,please contact Nortel Networks Technical Support.

    Use the command: on each card, d sh ca/* bus/* and check the shelf bus with command:d sh bus/*

    Bus Test

    Note, there is a loss of redundancy on the back plane during this check. Please perform

    the test during maintenance window.> STEP 1: Before doing a bus test, you need to lock the bus you are going to check. The

    default time of this test is 2 min. You will need to set it to 5 min.

    Use the command: set sh bus/x test duration 5 and lock sh bus/x

    > STEP 2: Start the test

    Use command: start sh bus/x test

    > STEP 3: Wait until the console displays:

    Shelf Bus/x Test

    Test stopped

    Note: On the console you get some alarms about the bus. This is normal.

  • 8/3/2019 9_PCUSN PMA

    13/18

    13

    Passport Bus Status and test (continued)

    > STEP 4: Check the bus test results.

    Use command: d sh bus/x test

    Results:

    In the SelfTestResults, you should get a + for each card.

    In the ClockSourceTestResults, you should get a + for each card.

    In the BroadCastTestResults, you should get a + between each card.

    In the PingTestResults, you should not have any failure.

    If any one of these conditions isnt satisfied, please contact TAS.

    > STEP 5: Unlock the bus that was tested.

    Use command: Unlock sh bus/x

    Repeat the same operation for bus y.

    > STEP 6: Procedure completed.

  • 8/3/2019 9_PCUSN PMA

    14/18

    14

    > Important note:

    The suggested CP/E3C/PCUSP Card switchover should be performedduring maintenance window as the CP switchover will impact service.

  • 8/3/2019 9_PCUSN PMA

    15/18

  • 8/3/2019 9_PCUSN PMA

    16/18

    16

    Redundant CP/E3C (DS3)/PCUSP CardSwitchover (Continued)

    > STEP 6: Do a CP switchover.

    Use the command: switchover lp/0

    > STEP 7: After switchover, check the status of the new active CP card and wait 10 min.

    Use the command: d lp/0

    > STEP 8: Check of PCUSP redundancy

    Display the status of PCUSP card , and check the current active PCUSP card.

    Use the command: d lp/1

    > STEP 9: Reset the current passive PCUSP card (e.g. if the activeCard = Shelf Card/13the passive is shelf Card/1).

    Use the command: reset sh ca/1

    > STEP 10: Check that the alarm is cleared

    > STEP 11: After the reset , check the status of the PCUSP card and wait 10 min.

    Use the command: d lp/1

  • 8/3/2019 9_PCUSN PMA

    17/18

    17

    Redundant CP/E3C (DS3)/PCUSP CardSwitchover (Continued)

    > STEP 12: Switchover the PCUSP board (WARNING: SERVICE IMPACTING OPERATION).

    Use the command: switchover lp/1

    Repeat the steps for the other lp (usually lp/13) of the PCUSN 24.

    > STEP 13: Check of E3C redundancy :

    Display the status of E3C card , and check the current active E3C card.

    Use the command: d lp/5

    > STEP 14: Reset the current passive E3C card (e.g. if the activeCard = Shelf Card/10 the passivecard is Shelf card/5).

    Use the command: reset sh ca/5

    > STEP 15: Check the status of the E3C card and wait 10 min.

    Use the command: d lp/5

    > STEP 16: Switchover the E3C board (WARNING: SERVICE IMPACTING OPERATION). Use thecommand: switchover lp/5

    > STEP 17: After switchover, check the status of the new active E3C card.

    Use the command: d lp/5

    > STEP 18: Procedure completed

  • 8/3/2019 9_PCUSN PMA

    18/18

    18

    References

    > Nortel OMC-R NTP Cross Reference

    411-9001-091 PCUSN Reference Manual

    241-5701-050 Passport 7400,15000,20000 Commands

    241-5701-520 Passport 7400,15000,20000 Troubleshooting guide

    241-7401-215 Passport 7400 Hardware Maintenance Guide