a-07 · 2018-03-30 · 139.70cm 55" water inlet (3/4" garden hose connection) water...
TRANSCRIPT
88.27cm
34 34 "
56.20cm
22 18 "
HEATING ELEMENT
POWER INLETLOCATION
127cm
50"
WATER INLET (3/4" GARDEN HOSE CONNECTION)
NOTE:MAINTENANCE REQUIRES 4' MIN. ON ELEMENT HEAD SIDE AND 2' MIN. ON ALL OTHER SIDES
STAINLESS STEEL FLOAT TANK
WATER OUTLET(3/8" QUICK COUPLER)
ELECTRICAL ENCLOSURE
OPTIONALHYDROBLEND OPTIONAL
DUAL FILTER
43.18cm
17"
121.92cm
48"
TEFC MOTOR INDUSTRIAL PUMP
Copyright © 2010 SIOUX CORPORATION. This information is property of Sioux Corporation, is subject to recall at any time, and is not to be used in any way detrimental to Sioux’s interest. Use of material is subject to the Terms of Website Use listed on the www.sioux.com website.
NOTE: CASTERS ADD 8" (20.32cm) TO HEIGHT SKID WILL ADD 6"(15.24cm) TO HEIGHT
APPLICABLE MACHINES
MODEL APPROX. WEIGHTLB KG
60HZ UNITSEN0.8S250-60 725 330
EN2.0P1200-60 725 330EN2.0P1800-60 750 340EN2.0P3000-60 775 352
50HZ UNITSEN0.8S250-50 725 330
EN2.5P1200-50 725 330EN2.5P1800-50 750 340EN2.5P3000-50 775 352
4 3 1
A
C
D
FR21120-W P-SERIES
A-07
4 3 2 1
D
C
B
A
DW
G N
O.
REVSHEET
1/1
INCHES
2°ANGULAR:
.0625[1/16]LINEAR:
TOLERANCES
UNLESS NOTED:DIMENSIONS
DO NOT SCALE DRAWING
THIRD-ANGLE PROJECTION
4/22/14LNCHK
DRN
EN-NO.1 FRAME NON-XP
PROPRIETARY AND CONFIDENTIALONE SIOUX PLAZA, BERESFORD, SD 57004
SIOUX CORPORATION
EN-SERIES SINGLE ELEMENT P-SERIES NON-XP MACHINESFILEASIZE SCALE
SHREV1/1
1:16
A-07FR21120-W P-SERIES
THE INFORMATION CONTAINEDIN THIS DRAWING IS THE SOLEPROPERTY OF SIOUX CORP.
ANY REPRODUCTION IN PART ORAS A WHOLE WITHOUT WRITTEN
PERMISSION OF SIOUX CORP IS PROHIBITED.
QC
137.16cm
54"
STAINLESS STEEL FLOAT TANKWATER INLET(3/4" GARDEN HOSE CONNECTION)
NOTE:MAINTENANCE REQUIRES 4' MIN. ON ELEMENT HEAD SIDE AND 2' MIN. ON ALL OTHER SIDES
WATER OUTLET(3/8" QUICK COUPLER)
EXPLOSION PROOF ENCLOSURE:UL/cUL CERTIFIED FOR USE IN CLASS 1 DIV.1 GROUP C&DCLASS 2 DIV.1 GROUP F&G
50.48cm
19 78 "
132.08cm
52"
MOTOR:CLASS I DIV.1 GROUP C,DCLASS II DIV.1 GROUP F,G
INDUSTRIAL PUMP
109.70cm
43 316 "
63.50cm
25"
POWER INLET LOCATION
HEATING ELEMENT
Copyright © 2010 SIOUX CORPORATION. This information is property of Sioux Corporation, is subject to recall at any time, and is not to be used in any way detrimental to Sioux’s interest. Use of material is subject to the Terms of Website Use listed on the www.sioux.com website.
NOTE: CASTERS ADD 8" (20.32cm) TO HEIGHT SKID WILL ADD 6"(15.24cm) TO HEIGHT
APPLICABLE MACHINES
UNITS APPROX. WEIGHTLB KG
60HZ UNITSEN0.8S250-60XP 725 330
EN2.0P1200-60XP 725 330EN2.0P1800-60XP 775 352EN2.0P3000-60XP 875 398
50HZ UNITSEN0.8S250-50XP 725 330
EN2.5P1200-50XP 725 330EN2.5P1800-50XP 750 341EN2.5P3000-50XP 800 364
4 3 1
A
C
D
FR21122-W P-SERIES
A-05
4 3 2 1
D
C
B
A
DW
G N
O.
REVSHEET
1/1
INCHES
2°ANGULAR:
.0625[1/16]LINEAR:
TOLERANCES
UNLESS NOTED:DIMENSIONS
DO NOT SCALE DRAWING
THIRD-ANGLE PROJECTION
4/25/14LNCHK
DRN
FR21122 XP #1 FRAME.FORWARD PLUMBED
PROPRIETARY AND CONFIDENTIALONE SIOUX PLAZA, BERESFORD, SD 57004
SIOUX CORPORATION
EN-SERIES SINGLE ELEMENT P-SERIES XP MACHINESFILEASIZE SCALE
SHREV1/1
1:24
A-05FR21122-W P-SERIES
THE INFORMATION CONTAINEDIN THIS DRAWING IS THE SOLEPROPERTY OF SIOUX CORP.
ANY REPRODUCTION IN PART ORAS A WHOLE WITHOUT WRITTEN
PERMISSION OF SIOUX CORP IS PROHIBITED.
QC
129.06cm
50 1316 "
TEFC MOTOR
NOTE:MAINTENANCE REQUIRES 4' MIN. ON ELEMENT HEAD SIDE AND 2' MIN. ON ALL OTHER SIDES
WATER OUTLET(3/8" QUICK COUPLER)
ELECTRICAL ENCLOSURE
OPTIONALDUAL FILTER
OPTIONALHYDROBLEND
53.34cm
21"
123.98cm
48 1316 "
INDUSTRIAL PUMP
WATER INLET(3/4" GARDEN HOSE CONNECTION)
STAINLESS STEEL FLOAT TANK
97.16cm
38 14 "
66.36cm
26 18 "
POWER INLETLOCATION
HEATING ELEMENTS
NOTE: CASTERS ADD 8" (20.32cm) TO HEIGHT SKID WILL ADD 6"(15.24cm) TO HEIGHT
Copyright © 2010 SIOUX CORPORATION. This information is property of Sioux Corporation, is subject to recall at any time, and is not to be used in any way detrimental to Sioux’s interest. Use of material is subject to the Terms of Website Use listed on the www.sioux.com website.
APPLICABLE MACHINES
MODELS WEIGHTLB KG
60HZ UNITSEN1.6S250-60 600 273EN2.0S250-60 500 227
EN3.6P1200-60 625 284EN4.0P1800-60 700 318EN4.0P3000-60 950 432
50HZ UNITSEN1.6S250-50 600 273EN2.4S250-50 900 409
EN5.0P1200-50 625 284EN5.0P1800-50 700 318EN5.0P3000-50 950 432
4 3 1
A
C
D
FR21121-W P-SERIES
A-05
4 3 2 1
D
C
B
A
DW
G N
O.
REVSHEET
1/1
INCHES
2°ANGULAR:
.0625[1/16]LINEAR:
TOLERANCES
UNLESS NOTED:DIMENSIONS
DO NOT SCALE DRAWING
THIRD-ANGLE PROJECTION
4/24/14LNCHK
DRN
FR21121-W FORWARD PLUMBED NON-XP #2 FRAME
PROPRIETARY AND CONFIDENTIALONE SIOUX PLAZA, BERESFORD, SD 57004
SIOUX CORPORATION
EN-SERIES DUAL ELEMENT P-SERIES NON-XP MACHINESFILEASIZE SCALE
SHREV1/1
1:16
A-05FR21121-W P-SERIES
THE INFORMATION CONTAINEDIN THIS DRAWING IS THE SOLEPROPERTY OF SIOUX CORP.
ANY REPRODUCTION IN PART ORAS A WHOLE WITHOUT WRITTEN
PERMISSION OF SIOUX CORP IS PROHIBITED.
QC
139.70cm
55"
WATER INLET(3/4" GARDEN HOSE CONNECTION)
WATER OUTLET(3/8" QUICK COUPLER)
POWER INLETLOCATION
OPTIONALDUAL FILTER
OPTIONALHYDROBLEND
63.18cm
24 78 "
134.62cm
53"
INDUSTRIAL PUMP
MOTOR:CLASS I DIV.1 GROUP C,DCLASS II DIV.1 GROUP F,G
STAINLESS STEEL FLOAT TANK
109.54cm
43 18 "
76.52cm
30 18 "
EXPLOSION PROOF ENCLOSURE:UL/cUL CERTIFIED FOR USE IN CLASS 1 DIV.1 GROUP C&DCLASS II DIV.1 GROUP F&G
NOTE:MAINTENANCE REQUIRES 4' MIN. ON ELEMENT HEAD SIDE AND 2' MIN. ON ALL OTHER SIDES
HEATING ELEMENTS Copyright © 2010 SIOUX CORPORATION. This information is property of Sioux Corporation, is subject to recall at any time, and is not to be used in any way detrimental to Sioux’s interest. Use of material is subject to the Terms of Website Use listed on the www.sioux.com website.
NOTE: CASTERS ADD 8" (20.32cm) TO HEIGHT SKID WILL ADD 6" (15.24cm) TO HEIGHT
APPLICABLE MACHINES
MODELS APPROX. WEIGHTLB KG
60HZ UNITSEN1.6S250-60XP 825 375EN2.0S250-60XP 850 386
EN3.6P1200-60XP 850 386EN4.0P1800-60XP 950 432EN4.0P3000-60XP 950 432
50HZ UNITSEN1.6S250-50XP 850 386
EN5.0P1200-50XP 900 409EN5.0P1800-50XP 1125 511EN5.0P3000-50XP 1300 591
4 3 1
A
C
D
FR21123-W P-SERIES
A-06
4 3 2 1
D
C
B
A
DW
G N
O.
REVSHEET
1/1
INCHES
2°ANGULAR:
.0625[1/16]LINEAR:
TOLERANCES
UNLESS NOTED:DIMENSIONS
DO NOT SCALE DRAWING
THIRD-ANGLE PROJECTION
4/25/14LNCHK
DRNPROPRIETARY AND CONFIDENTIALONE SIOUX PLAZA, BERESFORD, SD 57004
SIOUX CORPORATION
EN-SERIES DUAL ELEMENT P-SERIES XP MACHINESFILEASIZE SCALE
SHREV1/1
1:16
A-06FR21123-W P-SERIES
THE INFORMATION CONTAINEDIN THIS DRAWING IS THE SOLEPROPERTY OF SIOUX CORP.
ANY REPRODUCTION IN PART ORAS A WHOLE WITHOUT WRITTEN
PERMISSION OF SIOUX CORP IS PROHIBITED.
QC
127cm
50"
WATER OUTLET(3/8" QUICK COUPLER)
NOTE:MAINTENANCE REQUIRES 4' MIN. ON ELEMENT HEAD SIDE AND 2' MIN. ON ALL OTHER SIDES
ELECTRICAL ENCLOSURE
88.27cm
34 34 "
56.20cm
22 18 "
WATER INLET(3/4" GARDEN HOSE CONNECTION)
POWER INLETLOCATION
HEATING ELEMENT
43.18cm
17"
121.92cm
48"
TEFC MOTOR INDUSTRIAL PUMP
Copyright © 2010 SIOUX CORPORATION. This information is property of Sioux Corporation, is subject to recall at any time, and is not to be used in any way detrimental to Sioux’s interest. Use of material is subject to the Terms of Website Use listed on the www.sioux.com website.
NOTE: CASTERS ADD 8" (20.32cm) TO HEIGHT SKID WILL ADD 6"(15.24cm) TO HEIGHT
APPLICABLE MACHINES
MODEL APPROX. WEIGHTLB KG
60HZ UNITSEN2.4H1200-60 475 216EN2.4H1800-60 525 239EN2.4H3000-60 525 239EN3.5H1200-60 525 239EN3.5H1800-60 550 250EN3.5H3000-60 675 307
50HZ UNITSEN2.5H1200-50 525 239EN2.5H1800-50 550 250EN2.5H3000-50 675 307
4 3 1
A
C
D
FR21120-W-H SERIES
A-08
4 3 2 1
D
C
B
A
DW
G N
O.
REVSHEET
1/1
INCHES
2°ANGULAR:
.0625[1/16]LINEAR:
TOLERANCES
UNLESS NOTED:DIMENSIONS
DO NOT SCALE DRAWING
THIRD-ANGLE PROJECTION
4/22/14LNCHK
DRNPROPRIETARY AND CONFIDENTIALONE SIOUX PLAZA, BERESFORD, SD 57004
SIOUX CORPORATION
EN-SERIES SINGLE ELEMENT H SERIES NON-XP MACHINESFILEASIZE SCALE
SHREV1/1
1:16
A-08FR21120-W-H SERIES
THE INFORMATION CONTAINEDIN THIS DRAWING IS THE SOLEPROPERTY OF SIOUX CORP.
ANY REPRODUCTION IN PART ORAS A WHOLE WITHOUT WRITTEN
PERMISSION OF SIOUX CORP IS PROHIBITED.
QC
137.16cm
54"
EXPLOSION PROOF ENCLOSURE:UL/cUL CERTIFIED FOR USE IN CLASS 1 DIV.1 GROUP C&DCLASS II DIV.1 GROUP F&G
NOTE:MAINTENANCE REQUIRES 4' MIN. ON ELEMENT HEAD SIDE AND 2' MIN. ON ALL OTHER SIDES
INDUSTRIAL PUMP
OPTIONALDUAL FILTER
OPTIONALHYDROBLEND
109.70cm
43 316 "
63.50cm
25"
WATER INLET (3/4" GARDEN HOSECONNECTION)
POWER INLET LOCATION
HEATING ELEMENT
50.48cm
19 78 "
132.08cm
52" MOTOR:CLASS I DIV. 1 GROUP C,DCLASS II DIV.1 GROUP F,G
WATER OUTLET(3/8" QUICK COUPLER)
Copyright © 2010 SIOUX CORPORATION. This information is property of Sioux Corporation, is subject to recall at any time, and is not to be used in any way detrimental to Sioux’s interest. Use of material is subject to the Terms of Website Use listed on the www.sioux.com website.
NOTE: CASTERS ADD 8" (20.32cm) TO HEIGHT SKID WILL ADD 6"(15.24cm) TO HEIGHT
APPLICABLE MACHINES
MODEL APPROX. WEIGHTLB KG
60HZ UNITSEN2.4H1200-60XP 725 330EN2.4H1800-60XP 750 341EN2.4H3000-60XP 800 364EN3.5H1200-60XP 750 341EN3.5H1800-60XP 800 364EN3.5H3000-60XP 850 386
50HZ UNITSEN2.5H1200-50XP 725 330EN2.5H1800-50XP 750 341EN2.5H3000-50XP 800 364
4 3 1
A
C
D
FR21122-W H-SERIES
A-07
4 3 2 1
D
C
B
A
DW
G N
O.
REVSHEET
1/1
INCHES
2°ANGULAR:
.0625[1/16]LINEAR:
TOLERANCES
UNLESS NOTED:DIMENSIONS
DO NOT SCALE DRAWING
THIRD-ANGLE PROJECTION
4/25/14LNCHK
DRNPROPRIETARY AND CONFIDENTIALONE SIOUX PLAZA, BERESFORD, SD 57004
SIOUX CORPORATION
EN-SERIES SINGLE ELEMENT H-SERIES XP MACHINESFILEASIZE SCALE
SHREV1/1
1:16
A-07FR21122-W H-SERIES
THE INFORMATION CONTAINEDIN THIS DRAWING IS THE SOLEPROPERTY OF SIOUX CORP.
ANY REPRODUCTION IN PART ORAS A WHOLE WITHOUT WRITTEN
PERMISSION OF SIOUX CORP IS PROHIBITED.
QC
97.16cm
38 14 "
100.33cm
39 12 "
ELECTRICALENCLOSURE
HEATING ELEMENTS
131.76cm
51 78 "
WATER INLET(3/4" GARDERN HOSE CONNECTION)
POWER INLETLOCATION
STAINLESS STEELFLOAT TANK
TEFC MOTOR
WATER OUTLET(3/8" QUICK COUPLER)
NOTE:MAINTAINENCE REQUIRES 4' MIN. ON ELEMENTHEAD SIDE AND 2' MIN. ON ALL OTHER SIDES
87.31cm
34 38 "
124.14cm
48 78 "
INDUSTRIAL PUMP
NOTE: CASTERS ADD 8" (20.32cm) TO HEIGHT SKID WILL ADD 6" (15.24cm) TO HEIGHT
Copyright © 2010 SIOUX CORPORATION. This information is property of Sioux Corporation, is subject to recall at any time, and is not to be used in any way detrimental to Sioux’s interest. Use of material is subject to the Terms of Website Use listed on the www.sioux.com website.
APPLICABLE MACHINES
MODEL APPROX. WEIGHTLB KG
EN3.0S250-60 900 409
4 3 1
A
C
D
FR21320-WA
-044 3 2 1
D
C
B
A
DW
G N
O.
REVSHEET
1/1
INCHES
2°ANGULAR:
.0625[1/16]LINEAR:
TOLERANCES
UNLESS NOTED:DIMENSIONS
DO NOT SCALE DRAWING
THIRD-ANGLE PROJECTION
07-16-14LCCHK
DRN
FR21320-W EN-Series Three Element Non-XP
PROPRIETARY AND CONFIDENTIALONE SIOUX PLAZA, BERESFORD, SD 57004
SIOUX CORPORATION
EN-SERIES P-SERIES THREE ELEMENT MACHINESFILEASIZE SCALE
SHREV1/1
1:18
A-04FR21320-W
THE INFORMATION CONTAINEDIN THIS DRAWING IS THE SOLEPROPERTY OF SIOUX CORP.
ANY REPRODUCTION IN PART ORAS A WHOLE WITHOUT WRITTEN
PERMISSION OF SIOUX CORP IS PROHIBITED.
QC
109.22cm
43"
100.33cm
39 12 "
HEATING ELEMENTS
EXPLOSION PROOF ENCLOSURE:UL/cUL CERTIFIED FOR USE INCLASS 1 DIV. 1GROUP C & DCLASS II DIV.1 GROUP F&G
143.51cm
56 12 "
WATER OUTLET(3/8" QUICK COUPLER)
WATER INLET(3/4" GARDERN HOSE CONNECTION)
NOTE:MAINTAINENCE REQUIRES 4' MIN. ON ELEMENTHEAD SIDE AND 2' MIN. ON ALL OTHER SIDES POWER INLET
LOCATION
MOTOR:CLASS I DIV.1GROUP C,DCLASS II DIV.1GROUP F,G
87.31cm
34 38 "
135.89cm
53 12 "
STAINLESS STEELFLOAT TANK
INDUSTRIAL PUMP
Copyright © 2010 SIOUX CORPORATION. This information is property of Sioux Corporation, is subject to recall at any time, and is not to be used in any way detrimental to Sioux’s interest. Use of material is subject to the Terms of Website Use listed on the www.sioux.com website.
APPLICABLE MACHINES
MODEL APPROX. WEIGHTLB KG
EN3.0S250-60XP 1500 682EN3.2S250-50XP
4 3 1
A
C
D
FR21124-W P-SERIESA
-044 3 2 1
D
C
B
A
DW
G N
O.
REVSHEET
1/1
INCHES
2°ANGULAR:
.0625[1/16]LINEAR:
TOLERANCES
UNLESS NOTED:DIMENSIONS
DO NOT SCALE DRAWING
THIRD-ANGLE PROJECTION
07-16-14LCCHK
DRN
FR21124-W EN-Series Three Element XP
PROPRIETARY AND CONFIDENTIALONE SIOUX PLAZA, BERESFORD, SD 57004
SIOUX CORPORATION
EN-SERIES THREE ELEMENT P-SERIES XP MACHINESFILEASIZE SCALE
SHREV1/1
1:20
A-04FR21124-W P-SERIES
THE INFORMATION CONTAINEDIN THIS DRAWING IS THE SOLEPROPERTY OF SIOUX CORP.
ANY REPRODUCTION IN PART ORAS A WHOLE WITHOUT WRITTEN
PERMISSION OF SIOUX CORP IS PROHIBITED.
QC
103.51cm
40 34 "
120.02cm
47 14 "
HEATING ELEMENTS
ELECTRICALENCLOSURE
129.22cm
50 78 "
94.62cm
37 14 "
INDUSTRIAL PUMP
STAINLESS STEELFLOAT TANK
136.84cm
53 78 "
WATER INLET(3/4" GARDERN HOSE CONNECTION)TEFC MOTOR
POWER INLETLOCATION
WATER OUTLET(3/8" QUICK COUPLER)
NOTE:MAINTAINENCE REQUIRES 4' MIN. ON ELEMENTHEAD SIDE AND 2' MIN. ON ALL OTHER SIDES
Copyright © 2010 SIOUX CORPORATION. This information is property of Sioux Corporation, is subject to recall at any time, and is not to be used in any way detrimental to Sioux’s interest. Use of material is subject to the Terms of Website Use listed on the www.sioux.com website.
NOTE: CASTERS ADD 8" (20.32cm) TO HEIGHT SKID WILL ADD 6" (15.24cm) TO HEIGHT
APPLICABLE MACHINES
MODEL APPROX. WEIGHTLB KG
EN4.0S250-60 1300 591
4 3 1
A
C
D
FR21125-WA
-044 3 2 1
D
C
B
A
DW
G N
O.
REVSHEET
1/1
INCHES
2°ANGULAR:
.0625[1/16]LINEAR:
TOLERANCES
UNLESS NOTED:DIMENSIONS
DO NOT SCALE DRAWING
THIRD-ANGLE PROJECTION
07-16-14LCCHK
DRN
FR21125-W EN-Series Four Element Non-XP
PROPRIETARY AND CONFIDENTIALONE SIOUX PLAZA, BERESFORD, SD 57004
SIOUX CORPORATION
EN-SERIES P-SERIES FOUR ELEMENT NON-XP MACHINESFILEASIZE SCALE
SHREV1/1
1:20
A-04FR21125-W
THE INFORMATION CONTAINEDIN THIS DRAWING IS THE SOLEPROPERTY OF SIOUX CORP.
ANY REPRODUCTION IN PART ORAS A WHOLE WITHOUT WRITTEN
PERMISSION OF SIOUX CORP IS PROHIBITED.
QC
124.78cm
49 18 "
128.91cm
50 34 "
EXPLOSION PROOF ENCLOSURE:UL/cUL CERTIFIED FOR USE INCLASS 1 DIV. 1GROUP C & DCLASS II DIV.1 GROUP F&G
HEATING ELEMENTS
135.26cm
53 14 "
103.51cm
40 34 "
STAINLESS STEELFLOAT TANK
INDUSTRIAL PUMP
142.24cm
56"
NOTE:MAINTAINENCE REQUIRES 4' MIN. ON ELEMENTHEAD SIDE AND 2' MIN. ON ALL OTHER SIDES
MOTOR:CLASS I DIV.1 GROUP C,DCLASS II DIV.1 GROUP F,G
WATER INLET(3/4" GARDERN HOSE CONNECTION)
WATER OUTLET(3/8" QUICK COUPLER)
POWER INLETLOCATION
Copyright © 2010 SIOUX CORPORATION. This information is property of Sioux Corporation, is subject to recall at any time, and is not to be used in any way detrimental to Sioux’s interest. Use of material is subject to the Terms of Website Use listed on the www.sioux.com website.
NOTE: CASTERS ADD 8" (20.32cm) TO HEIGHT SKID WILL ADD 6" (15.24cm) TO HEIGHT
APPLICABLE MACHINES
MODEL APPROX. WEIGHTLB KG
EN4.0S250-60XP 1900 864EN4.0S250-50XP 2300 1045
4 3 1
A
C
D
FR21126-W P-SERIESA
-034 3 2 1
D
C
B
A
DW
G N
O.
REVSHEET
1/1
INCHES
2°ANGULAR:
.0625[1/16]LINEAR:
TOLERANCES
UNLESS NOTED:DIMENSIONS
DO NOT SCALE DRAWING
THIRD-ANGLE PROJECTION
07-16-14LCCHK
DRNPROPRIETARY AND CONFIDENTIALONE SIOUX PLAZA, BERESFORD, SD 57004
SIOUX CORPORATION
EN-SERIES FOUR ELEMENT P-SERIES XP MACHINESFILEASIZE SCALE
SHREV1/1
1:20
A-03FR21126-W P-SERIES
THE INFORMATION CONTAINEDIN THIS DRAWING IS THE SOLEPROPERTY OF SIOUX CORP.
ANY REPRODUCTION IN PART ORAS A WHOLE WITHOUT WRITTEN
PERMISSION OF SIOUX CORP IS PROHIBITED.
QC
139.70cm
55"
POWER INLET LOCATION
WATER INLET (3/4" GARDEN HOSE CONNECTION)
NOTE:MAINTENANCE REQUIRES 4' MIN. ON ELEMENT HEAD SIDE AND 2' MIN. ON ALL OTHER SIDES
109.54cm
43 18 "
76.52cm
30 18 "
EXPLOSION PROOF ENCLOSURE:UL/cUL CERTIFIED FOR USE IN CLASS 1 DIV.1 GROUP C&DCLASS II DIV,1 GROUP F&G
HEATING ELEMENTS
63.18cm
24 78 "
134.62cm
53"
MOTOR:CLASS I DIV. 1. GROUP C,DCLASS II DIV. 1. GROUP F,G
INDUSTRIAL PUMP
WATER OUTLET(3/4" GARDEN HOSE)
Copyright © 2010 SIOUX CORPORATION. This information is property of Sioux Corporation, is subject to recall at any time, and is not to be used in any way detrimental to Sioux’s interest. Use of material is subject to the Terms of Website Use listed on the www.sioux.com website.
NOTE: CASTERS ADD 8" (20.32cm) TO HEIGHT SKID WILL ADD 6" (15.24cm) TO HEIGHT
APPLICABLE MACHINES
MODEL APPROX. WEIGHTLB KG
60HZ UNITSEN5.0H1200-60XP 900 409EN5.0H1800-60XP 1125 511EN5.0H3000-60XP 1150 523EN7.1H1200-60XP 1150 523EN7.1H1800-60XP 1175 534EN7.1H3000-60XP 1300 591
50HZ UNITSEN5.0H1200-50XP 900 409EN5.0H1800-50XP 1125 511EN5.0H3000-50XP 1150 523
4 3 1
A
C
D
FR21123 H-SERIESA
-054 3 2 1
D
C
B
A
DW
G N
O.
REVSHEET
1/1
INCHES
2°ANGULAR:
.0625[1/16]LINEAR:
TOLERANCES
UNLESS NOTED:DIMENSIONS
DO NOT SCALE DRAWING
THIRD-ANGLE PROJECTION
4/28/14LNCHK
DRNPROPRIETARY AND CONFIDENTIALONE SIOUX PLAZA, BERESFORD, SD 57004
SIOUX CORPORATION
EN-SERIES DUAL ELEMENT H-SERIES XP MACHINESFILEASIZE SCALE
SHREV1/1
1:16
A-05FR21123 H-SERIES
THE INFORMATION CONTAINEDIN THIS DRAWING IS THE SOLEPROPERTY OF SIOUX CORP.
ANY REPRODUCTION IN PART ORAS A WHOLE WITHOUT WRITTEN
PERMISSION OF SIOUX CORP IS PROHIBITED.
QC
66.36cm
26 18 "
ELECTRICAL ENCLOSURE
HEATING ELEMENTS
97.16cm
38 14 "
129.06cm
50 1316 "
WATER INLET(3/4" GARDEN HOSE CONNECTION)
NOTE:MAINTENANCE REQUIRES 4' MIN. ON ELEMENT HEAD SIDE AND 2' MIN. ON ALL OTHER SIDES
POWER INLETLOCATION
53.34cm
21"
123.98cm
48 1316 "
WATER OUTLET(3/8" QUICK COUPLER)
TEFC MOTOR
INDUSTRIAL PUMP
NOTE: CASTERS ADD 8" (20.32cm) TO HEIGHT SKID WILL ADD 6"(15.24cm) TO HEIGHT
Copyright © 2010 SIOUX CORPORATION. This information is property of Sioux Corporation, is subject to recall at any time, and is not to be used in any way detrimental to Sioux’s interest. Use of material is subject to the Terms of Website Use listed on the www.sioux.com website.
APPLICABLE MACHINES
MODEL APPROX. WEIGHTLB KG
60HZ UNITSEN5.0H1200-60 650 295EN5.0H1800-60 775 352EN5.0H3000-60 800 363EN7.1H1200-60 800 364EN7.1H1800-60 825 375EN7.1H3000-60 925 420
50HZ UNITSEN5.0H1200-50 650 295EN5.0H1800-50 775 352EN5.0H3000-50 800 364
4 3 1
A
C
D
FR21121-W H-SERIES
A-05
4 3 2 1
D
C
B
A
DW
G N
O.
REVSHEET
1/1
INCHES
2°ANGULAR:
.0625[1/16]LINEAR:
TOLERANCES
UNLESS NOTED:DIMENSIONS
DO NOT SCALE DRAWING
THIRD-ANGLE PROJECTION
4/24/14LNCHK
DRN
FR21121-W NON-XP #2 FRAME
PROPRIETARY AND CONFIDENTIALONE SIOUX PLAZA, BERESFORD, SD 57004
SIOUX CORPORATION
EN-SERIES DUAL ELEMENT H-SERIES NON-XP MACHINESFILEASIZE SCALE
SHREV1/1
1:16
A-05FR21121-W H-SERIES
THE INFORMATION CONTAINEDIN THIS DRAWING IS THE SOLEPROPERTY OF SIOUX CORP.
ANY REPRODUCTION IN PART ORAS A WHOLE WITHOUT WRITTEN
PERMISSION OF SIOUX CORP IS PROHIBITED.
QC