a-501-18_erratum
TRANSCRIPT
-
8/16/2019 A-501-18_Erratum
1/1
Refrigerant Properties
38
R22R124R142b
R134aR152aR125R143aR32
R227eaR236fa
R23
R404A R507AR407A R407FR422A
R437A
R407CR417A R417BR422DR427A R438A
R410A
ISCEON MO89
R508A R508B
R1234yf R1234ze(E)R513A (XP10)R450A (N-13)
R448A (N-40)R449A (XP40)
R717R723R600aR290R1270
R170
R744
AR4: accord ing to IPCC IV – time horizon 100 years –also basis for EU F-Gas Regulation 517/2014
N/A Data not yet published.
Alte rnat ive refri gerant has large r deviat ion inrefrigerating capacity and pressure
Alter nati ve re frigeran t has l arger devia tionbelow -60°C evaporating temperature
Also proposed as a component in R290/ 600a-Blends (direct alternative to R12)
Classification according to EN378-1and ASHRAE 34
According to EN 37 8-1: 2008 + A2: 201 2, Annex E
0.0550.0220.065
0
0
0
0
1810609
2310
1430124
35004470675
32209810
14800
39223985210718253143
1805
177423462920272921382264
2088
3805
1321413396
47
631601
13861397
08333
3
1
Composition
(Formula)
Substitute /
Alternativefor
ODP
[R11=1,0]
GWP(100a)
[CO2=1,0]
Practical
limit[kg/m3]
Safety
group
Application
range
5
HFC Blends
Halogen free Refrigerants
HFO and HFO/HFCBlends
0.30.11
0.066
0.250.0270.39
0.0560.061
0.590.59
0.68
0.520.530.330.290.29
0.08
0.310.150.070.260.280.08
0.44
N/A
0.230.2
0.058N/A 0.35N/A
N/A N/A
0.00035N/A
0.0110.0080.008
0.008
0.07
A1 A1 A2
A1 A2 A1 A2
A2L
A1 A1
A1
A1 A1 A1 A1 A1
A1
A1 A1 A1 A1 A1 A1
A1
N/A
A1 A1
A2L A2L A1 A1
A1 A1
B2B2 A3 A3 A3
A3
A1
09.14
CHClF2CHClFCF3CCIF2CH3
CF3CH2FCHF2CH3CF3CHF2CF3CH3CH2F2
CF3-CHF-CF3CF3-CH2-CF3
CHF3
R143a/125/134aR143a/125R32/125/134aR32/125/134aR125/134a/600a
R125/134a/600/601
R32/125/134aR125/134a/600R125/134a/600R125/134a/600aR32/125/143a/134aR32/125/134a/600/601a
R32/125
R125/218/290
R23/116R23/116
CF3CF=CH2CF3CH=CHFR1234yf/134aR1234ze(E)/134a
R32/125/1234yf/1234ze(E)/134aR32/125/1234yf/134a
NH3NH3 /R-E170C4H10C3H8C3H6
C2H6
CO2
R502 (R12 )
R114 , R12B1
R12 (R500)
R13 (R503)
R503
R134a
R404A,
R507A
R22 (R13B1 )
R22
R22 (R502)
R404A (R22)R404A (R22)R134aR404A (R22)R404A (R22)
R23
various
R12B1, R114R114
R12 (R22 )
mainly used aspart componentsfor blends
seepage 40
seepage 40
seepage 40
seepage 40
seepage 41
R13B1
Refrigerant
type
HCFC-Refrigerants
3
3
4
5
6
5 6
4
5
1
1
1
1
1
1
2
2
2
These st atements are valid subject to reser vations; they are based on information published by va rious refri gerant manufacture rs.
Fig. 33 Refrigerant properties (continued on Fig. 34)
1
HFC Single-component Refrigerants
E r r a t u m t o R e f r i g e r a n t R e p o r t 1 8 ( 0 9 . 2 0 1 4 )