a-501-18_erratum

Upload: rob-bossie

Post on 05-Jul-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/16/2019 A-501-18_Erratum

    1/1

    Refrigerant Properties

    38

    R22R124R142b

    R134aR152aR125R143aR32

    R227eaR236fa

    R23

    R404A R507AR407A R407FR422A 

    R437A 

    R407CR417A R417BR422DR427A R438A 

    R410A 

    ISCEON MO89

    R508A R508B

    R1234yf R1234ze(E)R513A (XP10)R450A (N-13)

    R448A (N-40)R449A (XP40)

    R717R723R600aR290R1270

    R170

    R744

     AR4: accord ing to IPCC IV – time horizon 100 years –also basis for EU F-Gas Regulation 517/2014

    N/A Data not yet published.

     Alte rnat ive refri gerant has large r deviat ion inrefrigerating capacity and pressure

     Alter nati ve re frigeran t has l arger devia tionbelow -60°C evaporating temperature

     Also proposed as a component in R290/ 600a-Blends (direct alternative to R12)

    Classification according to EN378-1and ASHRAE 34

     According to EN 37 8-1: 2008 + A2: 201 2, Annex E

    0.0550.0220.065

    0

    0

    0

    0

    1810609

    2310

    1430124

    35004470675

    32209810

    14800

    39223985210718253143

    1805

    177423462920272921382264

    2088

    3805

    1321413396

    47

    631601

    13861397

    08333

    3

    1

    Composition

    (Formula)

    Substitute / 

     Alternativefor

    ODP

    [R11=1,0]

    GWP(100a)

    [CO2=1,0]

    Practical

    limit[kg/m3]

    Safety 

    group

     Application

    range

    5

    HFC Blends

    Halogen free Refrigerants

    HFO and HFO/HFCBlends

    0.30.11

    0.066

    0.250.0270.39

    0.0560.061

    0.590.59

    0.68

    0.520.530.330.290.29

    0.08

    0.310.150.070.260.280.08

    0.44

    N/A 

    0.230.2

    0.058N/A 0.35N/A 

    N/A N/A 

    0.00035N/A 

    0.0110.0080.008

    0.008

    0.07

     A1 A1 A2

     A1 A2 A1 A2

     A2L

     A1 A1

     A1

     A1 A1 A1 A1 A1

     A1

     A1 A1 A1 A1 A1 A1

     A1

    N/A 

     A1 A1

     A2L A2L A1 A1

     A1 A1

    B2B2 A3 A3 A3

     A3

     A1

    09.14

    CHClF2CHClFCF3CCIF2CH3

    CF3CH2FCHF2CH3CF3CHF2CF3CH3CH2F2

    CF3-CHF-CF3CF3-CH2-CF3

    CHF3

    R143a/125/134aR143a/125R32/125/134aR32/125/134aR125/134a/600a

    R125/134a/600/601

    R32/125/134aR125/134a/600R125/134a/600R125/134a/600aR32/125/143a/134aR32/125/134a/600/601a

    R32/125

    R125/218/290

    R23/116R23/116

    CF3CF=CH2CF3CH=CHFR1234yf/134aR1234ze(E)/134a

    R32/125/1234yf/1234ze(E)/134aR32/125/1234yf/134a

    NH3NH3 /R-E170C4H10C3H8C3H6

    C2H6

    CO2

    R502 (R12 )

    R114 , R12B1

    R12 (R500)

    R13 (R503)

    R503

    R134a

    R404A,

    R507A 

    R22 (R13B1 )

    R22

    R22 (R502)

    R404A (R22)R404A (R22)R134aR404A (R22)R404A (R22)

    R23

    various

    R12B1, R114R114

    R12 (R22 )

    mainly used aspart componentsfor blends

    seepage 40

    seepage 40

    seepage 40

    seepage 40

    seepage 41

    R13B1

    Refrigerant

    type

    HCFC-Refrigerants

    3

    3

    4

    5

    6

    5 6

    4

    5

    1

    1

    1

    1

    1

    1

    2

    2

    2

     These st atements are valid subject to reser vations; they are based on information published by va rious refri gerant manufacture rs.

    Fig. 33 Refrigerant properties (continued on Fig. 34)

    1

    HFC Single-component Refrigerants

    E r r a t u m t o R e f r i g e r a n t R e p o r t 1 8 ( 0 9 . 2 0 1 4 )