a division of pabco® building products, llc … guide fire & sound rated systems a division of...

68
CONSTRUCTION GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately 18 mil s.f. of PABCO® Gypsum wallboard 2 nd Edition

Upload: truongque

Post on 12-May-2018

217 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

CONSTRUCTION GUIDEFIRE & SOUND RATED SYSTEMS

a division of PABCO® building products, LLC

tothe ®

MGM CityCenter, Las Vegas, NV: Utilized approximately 18 mil s.f. of PABCO® Gypsum wallboard 2nd Edition

Page 2: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

OutstandingSERVICE

Truck leaving our flagship Las Vegas, NV plant seen in background

Page 3: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

PABCO® Gypsum Construction Guide - Fire & Sound Rated SystemsCopyright - 2009, 2011 • 2nd Edition • July 2011PABCO® Gypsum, a division of PABCO® Building Products, LLCPO Box 417094 • Rancho Cordova • CA • 95741www.pabcogypsum.comTechnical Services: 866-282-9298Specifications by PABCO’s Technical Services • SJ7-2011 • 3000ea

Providing quality products and service since 1972, PABCO® Gypsum is one of the leading manufacturers of gypsum wallboard in the United States.

PABCO® Gypsum began manufacturing and shipping from their Newark, California facility in 1972. Five years later, PABCO Gypsum expanded with the acquisition of a gypsum board plant and gypsum quarry north of Las Vegas, Nevada. In 1998 and 2005, the Las Vegas plant was

expanded and modernized; now these two facilities combined supply over 1.65 billion annual square feet of gypsum board.

PABCO Building Products, LLC also owns and operates a gypsum paperboard plant in Vernon, California. This plant was acquired in 1984; modernized in 1998, 2005, and again in 2007 in concert with PABCO’s wallboard

production expansions. The plant’s production capacity, 3.3 billion square feet of gypsum paperboard annually, is enough to supply all of PABCO’s® requirements.

PABCO’s complete line of gypsum board products is used in virtually all types of construction, from residential to commercial and high-rise structures. From the beginning, quality has been the foundation of PABCO Gypsum. To ensure this quality, PABCO Paper supplies customized face and back paper for PABCO’s gypsum board. Underwriters Laboratories Inc, provides the required third-party inspection service for all PABCO’s fire-rated products and UL Classified labels are printed on the back of each fire-resistant panel.

Our PABCO Gypsum qualified and respected sales staff, supported by our “in-house” technical services department, stand ready as a team to assist in the selection of PABCO Gypsum products and systems for your next project.

PABCO®

SUSTAINABLE M

ATERIALS

PABCO® Gypsum’s “Quality-to-the-Core®” gypsum board products were selected for the construction of the recently dedicated (Jan. 2008) Ohlone College Newark Center for Health Sciences and Technology campus located in Newark, CA.

Awarded the prestigious “LEED® Platinum Certification” from the U.S. Green Building Council, the highest achievable level of stainability, PABCO® wallboard assisted in attaining this Platinum certification level.

(photo: S.Jones).

1. Ohlone College Publication: “The Greenest College In the World”

The Greenest College in the World!1

Page 4: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

ExtraordinaryPEOPLE

Page 5: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

PABCO® Gypsum Technical Services:Technical support is one of the most important services we provide to architects, engineers, and code officials, as well as our customer base of distributors and contractors. The correct selection, installation, and use of our products in commercial and residential construction is of the utmost importance to PABCO. Our goal is for the customer to be fully satisfied with our products, and this extends to assisting in selecting the proper products for your job. Our technical services support team is staffed by highly qualified experts in their field, who additionally serve on many industry standards committees and technical review boards. To this end, we provide you with the following ways to contact us for technical matters:

Technical Support, Samples, Literature: . . . . . . . . . . . . 866-282-9298Technical Support via email: . . . . . . . . . . . [email protected] Support via the internet: . . . . . . . . . www.pabcogypsum.com

Gypsum Products Directory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Product Packaging, Sizes, Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Product Certification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Sustainable Materials Info, Data, & LEED® Sheets . . . . . . . . . . . . . . . . . . . . . . . 6-7“Proud PABCO® Projects” - a PHOTO GALLERY . . . . . . . . . . . . . . . . . . . . . . . . . 8-11

SECTION II: Gypsum Wallboard Products Specification & Submittal Sheets:ABUSE CURB™ type X, Impact, Abrasion, Indentation, Scuff, Mold, Water Resistant 14-15FLAME CURB® type X, type XXX, type C . . . . . . . . . . . . . . . . . . . . . . . . 16-17MOLD CURB® Plus, Mold-Water Resistant type X . . . . . . . . . . . . . . . . . . . . . 18-19Exterior Soffit type X, type XXX, type C . . . . . . . . . . . . . . . . . . . . . . . . . 20-21Gypsum Sheathing type X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23PABCORE® Shaftliner type X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25PABCORE® MOLD CURB® Plus Shaftliner type X . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-27Ceiling Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28-29Regular Wallboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-31WATER CURB® Gypsum Backing Board type X . . . . . . . . . . . . . . . . . . . . 32-33

SECTION III: FIRE & SOUND RATED SYSTEMSFire Resistive Properties of Gypsum; Fire Safety in Building Design . . . . . . . . . . . . . .34Fire & Sound Rated Systems Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36UL® Assembly Cross Reference by PABCO product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37Guide to Assemblies - Fire & Sound . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-39Walls & Partitions, Steel Framed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-43Walls & Partitions, Wood Framed, Chase Walls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44-47Shaft Wall Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-49Area Separation Walls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50Floor Ceiling, Steel Framed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51-52Floor Ceiling, Wood Framed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53-57Roof Ceiling, Wood Framed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58-59Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60-61Beams & Girders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62

HOW

TABLE

Reach

Contents

to us

ofHOW

TABLE

Reach

Contents

to us

of page

Page 6: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

Quality to the Core®PRODUCTS

Page 7: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

"Quality to the Core" R

a division of PABCO® building products, LLC

REGULAR Gypsum BoardRegular 3/8" 48" 8'

Tapered C 1396 NARegular 1/2" 48" & 54" 8' - 14'

WATER CURB®

TYPE X

WATER CURB®

TYPE X

WATER CURB®

TYPE X

WATER CURB®

TYPE X

WATER CURB® Gypsum Backing Board - Treated Core

Regular 1/2"48" 8' - 12' Tapered C 1396

NA

Type X 5/8" PG-5W

MOLD CURB®PLUSMold, Water Resistant Gypsum Board

Regular 1/2"48" 8' - 12' Tapered C 1396

NA

Type X 5/8" PG-5W

12’ 12’ 12’ 12’ 12’ 12’ 12’ 12’

ABUSE CURB™ Impact, Abrasion, Indentation Scuff, Moisture & Mold Resistant Gypsum Board

Type X 5/8" 48" 12' Tapered C 1629 PG-5W

PABCORE® SHAFTLINER & MOLD CURB® PLUS SHAFTLINERGypsum Liner Board - Type X Core

1" 24" 8' - 14' Beveled C 1396 PG-10

CEILING BOARDGypsum Ceiling Board

Regular 1/2" 48" 12'Tapered

C 1396 NARound Edge

19673-00 19673-00 19673-00

EXTERIORGYPSUM

SOFFITBOARD

EXTERIORGYPSUM

SOFFITBOARD

PANEL DE YESO FABRICADO DE ACUERDO A LA NORMA ASTM C 1396 - PANEL DE YESO PARA SOFITO EXTERIOR

PABCO® GYPSUM, UNA DIVISIÓN DE PABCO® BUILDING PRODUCTS, LLC NEWARK, CALIFORNIA, USA 94560

PABCO® GYPSUM, UNA DIVISIÓN DE PABCO® BUILDING PRODUCTS, LLC NEWARK, CALIFORNIA, USA 94560

PANEL DE YESO FABRICADO DE ACUERDO A LA NORMA ASTM C 1396 - PANEL DE YESO PARA SOFITO EXTERIOR

GYPSUM BOARD MANUFACTURED TO MEET ASTM C 1396 - EXTERIOR GYPSUM SOFFIT BOARD

PABCO® GYPSUM, DIV. OF PABCO® BUILDING PRODUCTS, LLC, NEWARK, CA, 94560 USA

PABCO® GYPSUM, DIV. OF PABCO® BUILDING PRODUCTS, LLC, NEWARK, CA, 94560 USA

GYPSUM BOARD MANUFACTURED TO MEET ASTM C 1396 - EXTERIOR GYPSUM SOFFIT BOARD

PANEL DE YESOPARA

SOFITOEXTERIOR PANEL DE YESO

PARASOFITO

EXTERIOR

SUPER C

PANEL DE YESO FABRICADO DE ACUERDO A LA NORMA ASTM C 1396 - PANEL DE YESO PARA SOFITO EXTERIOR TIPO C

PABCO® GYPSUM, UNA DIVISIÓN DE PABCO® BUILDING PRODUCTS, LLC NEWARK, CALIFORNIA, USA 94560

PABCO® GYPSUM, UNA DIVISIÓN DE PABCO® BUILDING PRODUCTS, LLC NEWARK, CALIFORNIA, USA 94560

PANEL DE YESO FABRICADO DE ACUERDO A LA NORMA ASTM C 1396 - PANEL DE YESO PARA SOFITO EXTERIOR TIPO C

GYPSUM BOARD MANUFACTURED TO MEET ASTM C 1396 - EXTERIOR GYPSUM SOFFIT BOARD TYPE C

PABCO® GYPSUM, DIV. OF PABCO® BUILDING PRODUCTS, LLC, NEWARK, CA, 94560 USA

PABCO® GYPSUM, DIV. OF PABCO® BUILDING PRODUCTS, LLC, NEWARK, CA, 94560 USA

GYPSUM BOARD MANUFACTURED TO MEET ASTM C 1396 - EXTERIOR GYPSUM SOFFIT BOARD TYPE C

EXTERIORGYPSUM

SOFFITBOARDTYPE C

EXTERIORGYPSUM

SOFFITBOARDTYPE C

PANEL DE YESOPARA

SOFITOEXTERIOR

TIPO C PANEL DE YESOPARA

SOFITOEXTERIOR

TIPO C

5/8” x 12’

5/8” x12’5/8” x 12’

5/8” x 12’

5/8” x 12’

5/8” x 12’5/8” x 12’

5/8” x 12’

1/2” x 12’

1/2” x 12’ 1/2” x 12’

1/2” x 12’ 1/2” x 12’

1/2” x 12’ 1/2” x 12’

1/2” x 12’

EXTERIOR SOFFITExterior Gypsum Soffit Board

Regular 1/2"

48" 8-12' Tapered C 1396

PG-3

Type XXX 1/2" PG-C

Type X 5/8" PG-11

Type C 5/8" TYPE C

88

8 8

88

8 8

SHEATHINGGypsum Sheathing

Regular 1/2"48" 8' Square C 1396

NAType X 5/8" PG-5WS

PABCO® Product Description & Core Type Thickness (in) Width (in.) Length (ft.) Edge Type ASTM Std. UL Core Type

SJ- ver. 05-29-11/GPD PABCO® Gypsum

* PG-11 replaces PG-9

FLAME CURB®Type X, Type XXX, & Super C Cores

Type XXX 1/2"48"

8-12' Tapered C 1396

PG-3

Super C 1/2" PG-C

Type X 5/8" 48" & 54" PG-11*

Type C 5/8" 48" TYPE CGood to the left only11/2

11/2

TYPE XXX

TYPE XXX

11/2

11/2 TYPE XXX

SUPER C SUPER C

SUPER C

SUPER CSUPER C

SUPER C SUPER C

SUPER C

SUPER CSUPER C

“Quality to the Core”®

PRODUCT DIRECTORYStandards & Specifications

PABCO® Gypsum provides this “Product Directory” reference table as a listing of our gypsum board and gypsum sheathing products. Included below are the panel available thicknesses, sizes, edge types, applicable ASTM product Standards, and assigned UL gypsum core ‘types’ for each product listed.

Specific data for products listed below is available on their respective individual Specification/Submittal Sheets which are available from your PABCO® representative, as well as on our web site: www.pabcogypsum.com. Other lengths and edge types may be available on a special order basis. Contact your local PABCO® representative, or call PABCO® Technical Services at 866-282-9298.

PABCO® Gypsuma division of PABCO® building products, LLCPO Box 417094Rancho Cordova, CA 95741Technical Services: 866-282-9298www.pabcogypsum.com

Page #3

Page 8: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

"Quality to the Core" R

a division of PABCO® building products, LLC

Page #4

PRODUCTS, PACKAGING & WEIGHTS

SJones- ver 3-24-11/ PPW PABCO® Gypsum

Product & Thickness Size (ft) Pieces per Unit

Pieces per Truckload

Full Truckload Weight (approx.)*

Lbs perMSF*

REGULAR

1/4" 4 x 8 100 - - 1150

3/8" 4 x 8 60 - - 1330

1/2"

4 x 8 50 900 47,520

1650

4 x 9 50 800 47,5204 x 10 501/ 342 714 47,1244 x 12 501/ 342 6001/6122 47,520

4 x 14 50 500 46,200

4 x 15 48 480 47,520

54" x 8 50 800 47,520

54" x 10 54 648 48,114

54" x 12 50/34 5343/5444 47,579

FLAME CURB®

Type X

1/2"4 x 8 50 800 47,360

18504 x 10 50 650 48,100

4 x 12 54 540 47,952

5/8"

4 x 8 50/40 700 47,712

2130

4 x 8'-6" 50, 660 47,800

4 x 9 50/60 620 47,541

4 x 9'-6" 50 594 48,078

4 x 10 50/40 560 47,712

4 x 10'-6" 50/40 540 48,308

4 x 12 264/38/40 4684/4725 48,257

54" x 12' 26/40/42 420 48,308

FLAME CURB® SUPER-C 1/2" 4 x 12 54 486 47,589 2040

5/8" 4 x 12 42 420 48,384 2400

ABUSE CURB™ 5/8" 4 x 12 40 360 48,390 2800

WATER CURB®1/2"

4 x 8 50 90048,384 1680

4 x 12 50 600

5/8"4 x 8 50 650 47,840

23004 x 12 40 440 48,576

MOLD CURB® PLUS 1/2"

4 x 8 50 900 48,3841680

4 x 12 50 600 48,384

5/8"4 x 8 50 650 47,840

23004 x 12 40 440 48,576

SHEATHING1/2" 4 x 8 50 900 48,384 1680

5/8"4 x 8 50 650 47,840

23004 x 12 40 440 48,576

CEILING BOARDTE = Tapered Edge 6. 34pc Boom UnitsRE = Round Edge

1/2"

4 x 12 TE 50/346 600/6126 47,520

16504 x 12 RE 346 6126 48,470

4 x 14 TE 50 52048,040

4 x 14 RE 50 520

EXTERIOR SOFFIT1/2" 4 x 12 54 540 47,952 1850

5/8" 4 x 8 50 700 47,7122130

4 x 12 38 472 48,257

FLEXBOARD 3/8" 4 x 12 60 750 47,810 1330

PABCORE® SHAFTLINER & MOLD CURB® PLUS SHAFTLINER 1"

2 x 8 60 720

47,832 41502 x 10 60 600

2 x 12 60 480

Note: Listing herein does not guarantee product availability. *Weights are approximate. Special order sizes may be available.Updated: 03-24-11

1. 12 @ 50 = 600, 2. 18 boom units @34 = 612, 3. 10 @ 50 + 1 @ 34= 534, 4. 16 @ 34 = 544

4.18 @ 26 (boom units) = 468; 5.4 @ 38 + 8 @ 40 = 472

Page 9: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

SJ- ver 06-06-11/Cert PABCO® Gypsum

May 2011

Quality to the Core®

This is to certify that PABCO Gypsum, a division of PABCO Building Products, LLC, manufactures its gypsum board products in plants located in the United States with gypsum ore mined in North America to the following standards and/or Specifications. (Note - Federal Specifications have been withdrawn and replaced by the appropriate ASTM Standards).This certification letter meets the requirements of ASTM C 1264 – 05.

Technical Services: 866-282-9298www.pabcogypsum.com

DRAFT

Limited Warranty: PABCO® Building Products, LLC, warrants that on the date the gypsum board is shipped from its manufacturing plant the gypsum board is free from defects in materials and manufacture. NOTWITHSTANDING THE FOREGOING, IT IS THE RESPONSIBILITY OF THE GYPSUM BOARD APPLICATOR TO NOTIFY PABCO BUILDING PRODUCTS, LLC, IN WRITING WITHIN TWENTY FOUR (24) HOURS OF DISCOVERY OF ANY VISIBLY DEFECTIVE GYPSUM BOARD PRIOR TO SUCH VISIBLY DEFECTIVE GYPSUM BOARD BEING APPLIED; FAILURE TO DO SO MAY FURTHER LIMIT OR VOID THE RESPONSIBILITIES OF PABCO BUILDING PRODUCTS, LLC, UNDER THIS WARRANTY. This warranty will remain in place for one year from the date of shipment from the manufacturing plant. THIS EXPRESS WARRANTY IS THE EXCLUSIVE WARRANTY PROVIDED BY PABCO® BUILDING PRODUCTS, LLC, AND SUPERSEDES ANY PRIOR, CONTRARY OR ADDITIONAL REPRESENTATIONS, WHETHER ORAL OR WRITTEN. PABCO® BUILDING PRODUCTS, LLC, HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES – WHETHER EXPRESS, IMPLIED, OR STATUTORY – INCLUDING ANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

If the gypsum board fails to conform to the foregoing warranty in Paragraph 1 and such nonconformity is not due to misuse or improper maintenance or storage, Buyer shall notify PABCO® Building Products, LLC, in writing, and within 60 days of discovery, PABCO® Building Products, LLC, shall provide, at its sole and absolute discretion, one of the following: (i) repair or replacement of any nonconforming or defective gypsum wallboard; or (ii) credit or full refund of the purchase price. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER FOR ANY BREACH OF WARRANTY.

IN NO EVENT SHALL PABCO® BUILDING PRODUCTS, LLC, BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, or strict liability in tort or under any other legal theory.

Trademarks: The following trademarks used herein are owned by Pacific Coast Building Products and licensed to PABCO® Gypsum: PABCO®, PABCORE®, FLAME CURB®, WATER CURB®, MOLD CURB®, Quality to the Core®, and ABUSE CURB™. Note: Products described herein may not be available in all geographic markets. Consult your PABCO® Gypsum sales representative for information.

• ABUSE CURB™: (Type X Core) Mold-Resistant and Water-Resistant Gypsum Board – ASTM Standard C 1629/C 1629M – 06

• MOLD CURB® PLUS: (Regular or Type X Core) Mold-Resistant and Water-Resistant Gypsum Board – ASTM Standard C 1396/C 1396M – 09a, formerly C 630/C 630M – 03

• FLAME CURB® Gypsum Wallboard: (Type X, Type XXX, or Super ‘C’ Core) – ASTM Standard 1396/C 1396M – 09a Type X, formerly C 36/C 36M – 03

• Regular Wallboard and FLEX Wallboard: (Regular Core) – ASTM Standard C 1396/C 1396M – 09a, formerly C 36/C 36M – 03

• Gypsum Ceiling Board: (Regular Core) – ASTM Standard C 1396/C 1396M – 09a, formerly C 1395/C 1395M – 04

• WATER CURB® Gypsum Backing Board: (Regular or Type X Core) Water-Resistant Gypsum Backing Board - ASTM Standard C 1396/C 1396M – 09a, formerly C 630/C 630M - 03

• Gypsum Sheathing Board: (Regular or Type X Core) - ASTM Standard C 1396/C 1396M – 09a, formerly C 79/C 79M – 04a

• Exterior Gypsum Soffit Board: (Regular, Type X, Type XXX, or Super ‘C’ Core) – ASTM Standard C 1396/C 1396M – 09a, formerly C 931/C 931M – 04

• PABCORE® Gypsum Shaftliner Board and PABCORE® MOLD CURB® PLUS Gypsum Shaftliner Board: (Type X Core) - ASTM Standard C 1396/C 1396M – 09a, formerly C 442/C 442M – 04

In addition to meeting the standards noted to the left, all Type X, Type XXX or Super ‘C’ products are classified by Underwriters Laboratories, Inc. A UL label is printed on the back of each panel and an appropriate face label is printed along the tapered edge. ICC Evaluation Report - ESR 1338 covers generic gypsum board fire resistance rated systems. This report has the endorsement of PABCO Gypsum.

Application recommendations promulgated by the Gypsum Association (GA 216, GA 253 and 214) and/or ASTM (C 840 and C 1280) are to be considered as PABCO Gypsum application and finishing specifications.

Additional documentation concerning PABCO Gypsum products is available in the Technical Data section on the PABCO Gypsum web site: http://www.pabcogypsum.com/. ASTM documents may be purchased at www.astm.org.

Joint compounds and tape that meet ASTM C 475 shall be used for finishing PABCO Gypsum’s gypsum board products. The Levels of Gypsum Board Finish (GA-214) specifications shall be used for finishing joints and fastener heads (available from www.gypsum.org).

Foil may be applied to the back of ASTM C 1396 gypsum wallboard for the purpose of complying with ASTM C 1396 paragraphs 5.1.4, 6.1.4, 10.1.4 and 11.1.4.

Asbestos and VOC certification – laboratory tests have been conducted on PABCO Gypsum’s gypsum board in compliance with U.S. Government regulations and have shown that PABCO’s board contains no measurable asbestos content. PABCO Gypsum products have been tested by CHPS certified laboratories and shown to have zero (0) detectable VOCs.

Page #5

QUALIT Y to the CORE®

PABCO® Gypsuma division of PABCO® building products, LLCPO Box 419074Rancho Cordova, CA 95741

PRODUCT CERTIFICATION"Quality to the Core" R

a division of PABCO® building products, LLC

Page 10: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

SJ- ver.G/06-01-11/LEED® PABCO® GypsumPage #6

CommitmenttotheEnvironment

Description & Primary Uses:

LEED® is a trademark owned by the U.S. Green Building Council (USGBC)

PABCO® Gypsum is proud of our commitment to the environment, and to green building practices. As we are keenly aware of our important environmental responsibility, we work diligently to minimize our impact on our surroundings, as well as to minimize the natural resource base of our gypsum board manufacturing process.

As part of this important commitment, we support and participate in the LEED® sustainable materials program as promoted by the U.S. Green Building Council (USGBC).

PABCO® Gypsum’s universally well-respected “Quality to the Core®” products are successfully used in the construction of sustainable building projects around the country, while correspondingly assisting in achieving important LEED points. (See inside front cover as an example of a PABCO® LEED Platinum project.)

The facing page’s “Sustainable Materials Data Sheet” contains information applicable for products manufactured by PABCO® Gypsum at our manufacturing locations. The sustainable features listed are utilized in achieving credit towards all sustainable construction practices. If your project is located within 500 miles of one of our manufacturing facilities, additional credits may contribute to your project.

PABCO® GREEN FACTS:

• RECYCLED PAPER: Our wallboard is made with 100% recycled paper by our own PABCO® Paper Company (www.pabcopaper.com).

• RECYCLING WALLBOARD: Our California manufacturing facility accepts clean gypsum board scrap from new construction projects, which we recycle. This land fill diversion program processes the scrap gypsum for reuse in agriculture.

• ENERGY SAVINGS: Our Las Vegas, NV manufacturing facility acquires the “waste heat” from a turbine-driven electrical generating facility located on our premises, thus providing all of the heat necessary to operate one of our wallboard dryers. Rather than allowing this energy to be wasted into the atmosphere, we recycle it, saving untold millions of cubic feet of natural gas fossil fuel. This substantial contribution towards our “Commitment to the Environment” is a significant effort towards the reduction of green-house emissions.

• REDUCING TRANSPORTATION - ENERGY SAVINGS: Our raw gypsum ore is mined from our own quarry adjacent to our flagship Las Vegas plant (one of the largest plants in the U.S.), saving untold millions of gallons of fossil fuel (and associated emissions) otherwise used to transport ore via truck or ocean cargo, unlike many of our competitors.

PABCO®

SUSTAINABLE M

ATERIALS

Commitment to the Environment, Commitment to the Core™

Page 11: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

"Quality to the Core" R

a division of PAB

CO®

buildin

g products, LLC

SJ- 5-31-11/LEED® PABCO® GypsumPage #7

PABCO® Gypsuma division of PABCO® building products, LLCPO Box 405Newark, CA 94560Technical Services: 866-282-9298www.pabcogypsum.com

“Quality to the Core”®

SUSTAINABLE MATERIALS Data Sheet

LEED®: “Leadership in Energy and Environmental Design”

PABCO® Gypsum provides the following information for use in selecting materials to achieve LEED® certification credits.Gypsum board credits which may apply to specific construction projects under LEED® project designations area as follows: For CI and NC: MR credit 4.1, 5.1, and 5.2. It is the responsibility of the design professional to access the applicability of specific credits to the project.LEED® project designations:• NC: New commercial construction and major renovation projects.• EB: Existing building operations and maintenance.• CI: Commercial Interiors projects.• CS: Core and shell projects.PABCO® Gypsum finished products have no measurable VOC content.

PABCO® Gypsum Manufacturing

PlantLocation

PostConsumerContent

%

Pre Consumer

Content%

TotalRecycledContent

%

Raw MaterialExtractionLocation

Las Vegas, Nevada USA 1 3 4 Las Vegas, NV

USA

The U.S. Green Building Council (USGBC) is a non-profit organization committed to expanding sustainable building practices. USGBC is composed of more than 13,500 organizations from across the building industry that are working to advance structures that are environmentally responsible, profitable, and healthy places to live and work. Members includes building owners and end-users, real estate developers, facility managers, architects, designers, engineers, general contractors, subcontractors, product and building system manufacturers, government agencies, and nonprofits.

LEED® Green Building Rating System™:

LEED® (Leadership in Energy and Environmental Design) is a voluntary, consensus-based national rating system for developing high-performance, sustainable buildings. Developed by USGBC (United States Green Building Council), LEED® addresses all building types and emphasizes state-of-the-art strategies for sustainable site development, water savings, energy efficiency, materials and resources selection, and indoor environmental quality. LEED® is a practical rating tool for green building design and construction that provides immediate and measurable results for building owners and occupants.

Sustainable Features:

Gypsum Board Recycled Content:

About USGBC:

LEED® is a trademark owned by the U.S. Green Building Council (USGBC)

Page 12: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

One of many PROUD PABCO® projects

Page 13: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

One of many PROUD PABCO® projectsLAS VEGAS, Nevada, USA MGM CityCenter:

PABCO® Gypsum’s Quality-to-the-Core® products were selected for the 4,004 room, 61-story Caesar Pelli Tower and

165,000 square-foot Casino in Las Vegas, Nevada.

As the focal tower of the $11+ billion, 68-acre CityCenter project, the Pelli Tower includes over 11 million square-feet of PABCO®

wallboard, shipped a mere 15 miles from our flagship, state-of-the-art, gypsum wallboard plant and quarry.

CityCenter is the western hemisphere’s single most expensive privately funded construction project! (photos: ©S.Jones)

Page 14: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

...more PROUD PABCO® projects

LOS ANGELES, CA: University of California Los Angeles, PABCO® FLAME CURB® & MOLD CURB® Plus, (photo: ©SJones).

LAS VEGAS, NV: FAIRFIELD TOWERS, 2 mil SF PABCO® FLAME CURB® and WATER CURB® wallboard, (photos: ©SJones).

LAS VEGAS, NV: PANAROMA #3 TOWER, 2 mil SF PABCO® FLAME CURB® & WATER CURB® wallboard, (photo: ©SJones).

Page 15: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

...more PROUD PABCO® projects

LAS VEGAS, NV: MANDALAY BAY Convention Center, 6 mil SF PABCO® FLAME CURB® and WATER CURB® wallboard, (photo: ©SJones).

Downtown LOS ANGELES, CA: ORSINI commercial/residential project , 3 mil SF PABCO® FLAME CURB®, SHEATHING, & WATER CURB®, (photo: ©SJones).

Page 16: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

tothe ®

Page 17: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

Section II:Products, Specifications & Submital Sheets

tothe ®

Page 18: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

12’

12’

12’

12’

"Quality to the Core" R

a division of PABCO® building products, LLC

Description:

PABCO® Gypsum Specification PGS-011ASTM specification C 1629

PABCO® ABUSE CURB™ type X gypsum panels are comprised of a proprietary high density fire resistant type X gypsum core that incorporates the MOLD CURB® Plus technology. This product is designed for interior wall assemblies where surface durability (abrasion and indentation resistance), and mold and water resistance are primary considerations.

PABCO® ABUSE CURB™ type X gypsum panels are encased in a heavy and durable 100% recycled light-blue colored mold/mildew abrasion-resistant face paper, and 100% recycled heavy mold/mildew resistant gray liner paper on the back side. This product features a tapered edge formation that provides a recessed area to allow for the finished joint system to be below the decorating surface, resulting in a monolithic wall finish. The ends are cut square and finished smooth.

PABCO® ABUSE CURB™ type X gypsum panels are intended for interior applications, and shall not be used where there will be direct exposure to water or continuous high humidity before, during, and after construction. Avoid exposure to temperatures exceeding 125° F (52° C) for an extended period of time.

PABCO® ABUSE CURB™ type X gypsum panels are a non-structural panel, not intended to be used as a structural fastener base or to support wall or ceiling mounted objects.

All materials used in conjunction with the application of PABCO® ABUSE CURB™ type X gypsum panels shall be as specified in the applicable specific test report.

PABCO® ABUSE CURB™ gypsum panels are a high density formulated core that provides superior resistance to abrasion and surface indention. These gypsum panels have been designed and tested for use on high traffic interior walls (i.e. schools, hospitals, corrections facilities and offices), and partitions in either new or renovation construction applications where surface durability, abrasion, indentation, water and mold/mildew resistance are the desired attributes for the finished wall.

PABCO® ABUSE CURB™ gypsum panels are designed for direct mechanical attachment (nail, screw or adhesive) to wood or metal substrates, or attached to an existing surface using fasteners or adhesives. With the wallboard joints properly treated per GA-216 and GA-214, PABCO® ABUSE CURB™ gypsum panels will resist the passage of smoke.

Primary Uses:

Limitations:

Application:

tothe ®

PABCO® Gypsum endorses the Gypsum Association’s publication GA-216 as its application document.

* Abuse Resistant

Submittal 09 29 00

ABUSE CURB™ Impact-Abrasion-Indentation-Scuff

Mold & Water Resistant Gypsum Board

PABCO® Gypsuma division of PABCO® building products, LLCPO Box 419074Rancho Cordova, CA 95741Technical Services: 866-282-9298www.pabcogypsum.com

Page 19: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

Page #15

12’

12’

12’

12’

Storage & Handling:

Testing Data:

Fire Resistant Ratings:

Applicable Standards & Technical Data:

Mold & Water Resistance:

Submittal Approvals:

SJ- 06-06-11/ABUSE CURB™ PABCO® Gypsum

Store all PABCO® gypsum panels flat; do not store on edge as panels are heavy and may fall over causing injury or death. Store in an area that offers protection from adverse weather conditions, condensation, and other forms of moisture. Avoid job site conditions that expose gypsum board to water or moisture. Plastic shipping bags are temporary, and intended for protection during transit only, and must be removed promptly upon arrival. Store gypsum board under protected cover, off the ground with sufficient support to prevent sagging. Exercise proper care to avoid impact, scuffing of the paper faces, undue flexing, and damage to board edges, corners, and ends.

Manufacturing: ASTM C 1629 Federal Specification SS-L-30D Type VII Grade WX* Installation: Gypsum Association GA-216, GA-214; www.gypsum.org ASTM C 840; www.astm.orgMold Resistance: ASTM D 3273Surface Burning Characteristics: ASTM E 84, Flame Spread 15, Smoke Developed 0“R” value: 5/8" = 0.48 Thermal ResistanceVOC/Asbestos: Free of VOC (Volatile Organic Compound) & asbestosMaterial Safety Data Sheet: MSDS available at www.pabcogypsum.com, Technical DataPABCO Gypsum: “Construction Guide: Fire & Sound Rated Systems”Recycled Content: Refer to PABCO® Sustainable Materials Data Sheet for plant specific details.Please check our website at www.pabcogypsum.com for the latest edition of this specification.* The federal specification for gypsum board, SS-L-30d was withdrawn in 1984. It is provided here for informational purposes only.

Job name:

Contractor: Date:

Product Data,Sizes and Types:

Product UL Core Type Thickness Width Length1 Weight2

ABUSE CURB™type X PG-5W 5/8" 48" 12' 2.9 lbs/ft2

Packaging: 2 pieces per bundle, face-to-face, and end labeled.Edge type: Tapered Edge 1 Other lengths may be available on a special order basis. 2 Represents approximate weight for design and shipping purposes.

PABCO® ABUSE CURB™ abuse-resistant gypsum panels have been engineered with a water-resistant chemistry that provides the most enhanced water and mold-resistant protection available in gypsum board products, to provide protection against mold due to chemical treatment of the paper facings and the gypsum core, as compared to untreated gypsum panels. In independent laboratory tests per ASTM D 3273 (Standard Test Method for Resistance to Growth of Mold on the Resistance Surface of Interior Coatings in an Environmental Chamber), PABCO® ABUSE CURB™ abuse-resistant gypsum panel products achieved a 10 rating, the highest level of performance for this test method.

No material may be classified as mold-proof. Prolonged exposure to moisture can result in the growth of mold or mildew on any surface. The use of good design, with proper handling and construction practices, is the most effective and best method to minimize mold. This includes avoiding water exposure during all phases of the project, such as: storage, handling, shipping, and product installation and system maintenance both before and after project completion.

Fire Resistance Rated assembly designs are promulgated from tests performed at IAS* certified independent testing laboratories. These designs include specific materials assembled in a precise configuration. When choosing construction details to achieve specific fire resistance rated requirements, care must be taken to insure that each component of the specified assembly is the proper one specified in the test report, and assembled in accordance with the specific requirements of the assembly. *(The International Accreditation Service —IAS— is a non-profit, public benefit corporation and a leading accreditation body in the United States. Internationally recognized, accreditation by IAS makes it easier to market products and services both inside and outside the United States.)

Surface Abrasion Resistance: Tested in accordance with modified ASTM 4977, Classification Level 2Indentation Resistance: Tested in accordance with ASTM D 5420, Classification Level 1 Soft Body Impact: Tested in accordance with ASTM E 695, Classification Level 1Hard Body Impact: Tested in accordance with ASTM C 1629 Tested 40 ft-lbsNote: Independent testing performed by Intertek Testing Services

Limited Warranty: PABCO® Building Products, LLC, warrants that on the date the gypsum board is shipped from its manufacturing plant the gypsum board is free from defects in materials and manufacture. NOTWITHSTANDING THE FOREGOING, IT IS THE RESPONSIBILITY OF THE GYPSUM BOARD APPLICATOR TO NOTIFY PABCO BUILDING PRODUCTS, LLC, IN WRITING WITHIN TWENTY FOUR (24) HOURS OF DISCOVERY OF ANY VISIBLY DEFECTIVE GYPSUM BOARD PRIOR TO SUCH VISIBLY DEFECTIVE GYPSUM BOARD BEING APPLIED; FAILURE TO DO SO MAY FURTHER LIMIT OR VOID THE RESPONSIBILITIES OF PABCO BUILDING PRODUCTS, LLC, UNDER THIS WARRANTY. This warranty will remain in place for one year from the date of shipment from the manufacturing plant. THIS EXPRESS WARRANTY IS THE EXCLUSIVE WARRANTY PROVIDED BY PABCO® BUILDING PRODUCTS, LLC, AND SUPERSEDES ANY PRIOR, CONTRARY OR ADDITIONAL REPRESENTATIONS, WHETHER ORAL OR WRITTEN. PABCO® BUILDING PRODUCTS, LLC, HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES – WHETHER EXPRESS, IMPLIED, OR STATUTORY – INCLUDING ANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

If the gypsum board fails to conform to the foregoing warranty in Paragraph 1 and such nonconformity is not due to misuse or improper maintenance or storage, Buyer shall notify PABCO® Building Products, LLC, in writing, and within 60 days of discovery, PABCO® Building Products, LLC, shall provide, at its sole and absolute discretion, one of the following: (i) repair or replacement of any nonconforming or defective gypsum wallboard; or (ii) credit or full refund of the purchase price. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER FOR ANY BREACH OF WARRANTY.

IN NO EVENT SHALL PABCO® BUILDING PRODUCTS, LLC, BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, or strict liability in tort or under any other legal theory.

Trademarks: The following trademarks used herein are owned by Pacific Coast Building Products and licensed to PABCO® Gypsum: PABCO®, PABCORE®, FLAME CURB®, WATER CURB®, MOLD CURB®, Quality to the Core®, and ABUSE CURB™. Note: Products described herein may not be available in all geographic markets. Consult your PABCO® Gypsum sales representative for information.

Page 20: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

Goo

d to

the

left

onl

ySU

PER

CSU

PER

C

SUPE

R C

SUPER C

SUPER C

SUPER CSUPER C

SUPER C

SUPER C SUPER C

SUPER CSUPER C

SUPER C

SUPER C SUPER C

SUPE

R C

SUPE

R C

SUPE

R C

SUPER C

SUPER C

11/2

11/2

TYPE

XXX

TYPE XXX

11/2

11/2TYPE XXX

"Quality to the Core" R

a division of PABCO® building products, LLC

Description: PABCO® FLAME CURB® gypsum wallboard is a family of gypsum panel products composed of a fire-resistant gypsum core, reinforced with glass fibers which provides increased strength and enhanced fire-resistant properties. The face paper is folded around the long edges to reinforce as well as to protect the core; the panel ends are cut square. The long panel edges are tapered, allowing a recessed joint area to be reinforced and concealed to create a monolithic wall or ceiling surface suitable for decoration. PABCO® 5/8" FLAME CURB® type X and 1/2" FLAME CURB® type XXX meet and/or exceed the requirements specified by ASTM under its wallboard standard ASTM C 1396 type-X. FLAME CURB® Super ‘C’, in thicknesses of 1/2" and 5/8", exceed all of these previously mentioned “classified” core formulations in fire-resistance performance. (Systems are specifically tested at approved laboratories (see listing under Application) using these various core formulas, and those systems which successfully pass the stringent fire tests are approved for construction and are listed in the fire testing lab directory or in the Gypsum Association Fire Resistance Design Manual GA-600).PABCO® FLAME CURB® is manufactured with 100% recycled paper on face and back sides, affording a surface designed to receive joint treatment, paint, wall covering, or textured coatings.

PABCO® Gypsum Specification PGS-002ASTM specification C 1396Available in MOLD CURB® Plus type X

PABCO® Gypsum endorses the Gypsum Association’s publication GA-216 and ASTM Standard Specification C 840 as its application documents, which provide detailed instructions on the standard application of wallboard panels and proper joint finishing procedures.PABCO® FLAME CURB® systems must be installed in strict compliance with the detailed fire test assembly description, including core types and other components such as studs, fastener spacing and fasteners required, and applied as tested. To qualify for listed sound ratings, special caulking, insulation, or clips are generally added to the systems as detailed in the test report.Those systems that have been fire and sound tested are listed in the following: • Gypsum Association “Fire Resistance Design Manual” (GA-600). • PABCO® Gypsum Quality to the Core® Brochure (see PABCO® Gypsum website).• ICC: ESR 1338.• UL “Fire Resistance Directory”.• ITS, NGTS, NRC, RAL, SWRi, UL, or WFCi Test Reports.

Finishing of joints, wall or ceiling surfaces, and covering fasteners, is addressed in GA-214, GA-216, and ASTM C 840.

Application:

PABCO® FLAME CURB® is a non-structural wall covering material intended for interior walls, ceilings, and partitions in residential and commercial applications which often require specific fire-resistant assemblies. Additional applications include use as a roof underlayment per GA-276. This product is designed for direct mechanical attachment to metal or wood framing members. With the wallboard joints properly treated per GA-216 and GA-214, PABCO® FLAME CURB® will resist the passage of smoke.

PABCO® FLAME CURB® is intended for interior applications, and shall not be used where there will be direct exposure to water or continuous high humidity before, during, and after construction. Avoid exposure to temperatures exceeding 125 oF (52 oC) for an extended period of time. PABCO® FLAME CURB® is a non-structural panel, not to be used as a structural fastener base or to support wall or ceiling mounted objects.All materials used in conjunction with the application of PABCO® FLAME CURB® type X, XXX, or Super ‘C’ gypsum panels in Fire or Sound Rated systems shall be as specified in the applicable specific test report.

FLAME CURB® Type X, Type XXX, Type C

Gypsum Wallboard

Submittal 09 29 00

tothe ®

PABCO® Gypsuma division of PABCO® building products, LLCPO Box 417094Rancho Cordova, CA 95741Technical Services: 866-282-9298www.pabcogypsum.com

Primary Uses:

Limitations:

Page 21: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

SUPE

R C

SUPE

R C

SUPE

R C

SUPER C

SUPER C

SUPER CSUPER C

SUPER C

SUPER C SUPER C

SUPER CSUPER C

SUPER C

SUPER C SUPER C

SUPE

R C

SUPE

R C

SUPE

R C

SUPER C

SUPER C

11/2

11/2

TYPE

XXX

TYPE XXX

11/2

11/2TYPE XXX

Goo

d to

the

left

onl

y

Storage & Handling:

SJ/06-06-11/Flame Curb® PABCO® Gypsum

Store all PABCO® gypsum panels flat; do not store on edge as panels are heavy and may fall over causing injury or death. Store in an area that offers protection from adverse weather conditions, condensation, and other forms of moisture. Avoid job site conditions that expose gypsum board to water or moisture. Plastic shipping bags are temporary, intended for protection during transit only, and must be removed promptly upon arrival. Store gypsum board under protected cover, off the ground with sufficient support to prevent sagging. Exercise proper care to avoid impact, scuffing of the paper faces, undue flexing, and damage to board edges, corners, and ends.

Manufacturing: ASTM C 1396; www.astm.org Federal Specification SS-L-30D Type III, Grade X *Installation: Gypsum Association GA-216, GA-214; www.gypsum.org ASTM C 840, www.astm.orgFire-Resistant Assemblies: Gypsum Association GA-600, Fire Design Manual Underwriters Laboratories, UL Fire Resistance Directory Surface Burning ASTM E 84; UL: Fire Resistance DirectoryCharacteristics: Flame Spread 15, Smoke Developed 0Non-Combustible: ASTM E 136, www.astm.orgR value: 1/2" = 0.45; 5/8" = 0.48 Thermal ResistanceVOC/Asbestos content: Free of VOC (Volatile Organic Compound) & asbestosMaterial Safety Data Sheet: MSDS available at www.pabcogypsum.com, Technical DataPABCO Gypsum: “Construction Guide - Fire & Sound Rated Systems”Foil Application: Foil may be applied to the back of ASTM C 1396 gypsum wallboard for the purpose of complying with ASTM C 1396 paragraph 5.1.Recycled Content: Refer to PABCO® Sustainable Materials Data Sheet for plant specific details.Please check our website at www.pabcogypsum.com for the latest edition of this specification.

* The federal specification for gypsum board, SS-L-30d was withdrawn in 1984. It is provided here for informational purposes only.

Fire Resistance Rated assembly designs are promulgated from tests performed at IAS* certified independent testing laboratories, and these designs include specific materials assembled in a precise configuration. When choosing construction details to achieve specific fire resistance rated requirements, care must be taken to insure that each component of the specified assembly is the proper one specified in the test report, and assembled in accordance with the specific requirements of the assembly. *(The International Accreditation Service —IAS— is a non-profit, public benefit corporation and a leading accreditation body in the United States. Internationally recognized, accreditation by IAS makes it easier to market products and services both inside and outside the United States.)

Product UL Core Type Edge Type1 Thickness2 Width2 Length3 Weight4

Type XXX PG-3 TE 1/2" 48" 8', 12' 1.9 lbs/ft2

Super C PG-C TE 1/2" 48" 12' 2.0 lbs/ft2

Type X PG-11 TE & RE1 5/8" 48"&54" 8'-12' 2.2 lbs/ft2

Super C TYPE C TE 5/8" 48" 12' 2.4 lbs/ft2

Packaging: 2 pieces per bundle, face-to-face, and end labeled.1 Edge types: Tapered Edge (TE). Round Edge (RE) is available (only) on FLAME CURB® 5/8" x 48" widths.2 Units of measure: inches.3 Units of measure: feet. Other lengths may be available on a special order basis. Refer to PABCO’s “Products-

Packaging-Weights” page. Consult with your local PABCO® representative, or call PABCO® Technical Assistance.4 Represents approximate weight for design and shipping purposes. A more exact weight may be available for your

area; consult with your local PABCO® representative, or call PABCO® Technical Assistance.

Page 17

Limited Warranty: PABCO® Building Products, LLC, warrants that on the date the gypsum board is shipped from its manufacturing plant the gypsum board is free from defects in materials and manufacture. NOTWITHSTANDING THE FOREGOING, IT IS THE RESPONSIBILITY OF THE GYPSUM BOARD APPLICATOR TO NOTIFY PABCO BUILDING PRODUCTS, LLC, IN WRITING WITHIN TWENTY FOUR (24) HOURS OF DISCOVERY OF ANY VISIBLY DEFECTIVE GYPSUM BOARD PRIOR TO SUCH VISIBLY DEFECTIVE GYPSUM BOARD BEING APPLIED; FAILURE TO DO SO MAY FURTHER LIMIT OR VOID THE RESPONSIBILITIES OF PABCO BUILDING PRODUCTS, LLC, UNDER THIS WARRANTY. This warranty will remain in place for one year from the date of shipment from the manufacturing plant. THIS EXPRESS WARRANTY IS THE EXCLUSIVE WARRANTY PROVIDED BY PABCO® BUILDING PRODUCTS, LLC, AND SUPERSEDES ANY PRIOR, CONTRARY OR ADDITIONAL REPRESENTATIONS, WHETHER ORAL OR WRITTEN. PABCO® BUILDING PRODUCTS, LLC, HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES – WHETHER EXPRESS, IMPLIED, OR STATUTORY – INCLUDING ANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

If the gypsum board fails to conform to the foregoing warranty in Paragraph 1 and such nonconformity is not due to misuse or improper maintenance or storage, Buyer shall notify PABCO® Building Products, LLC, in writing, and within 60 days of discovery, PABCO® Building Products, LLC, shall provide, at its sole and absolute discretion, one of the following: (i) repair or replacement of any nonconforming or defective gypsum wallboard; or (ii) credit or full refund of the purchase price. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER FOR ANY BREACH OF WARRANTY.

IN NO EVENT SHALL PABCO® BUILDING PRODUCTS, LLC, BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, or strict liability in tort or under any other legal theory.

Trademarks: The following trademarks used herein are owned by Pacific Coast Building Products and licensed to PABCO® Gypsum: PABCO®, PABCORE®, FLAME CURB®, WATER CURB®, MOLD CURB®, Quality to the Core®, and ABUSE CURB™. Note: Products described herein may not be available in all geographic markets. Consult your PABCO® Gypsum sales representative for information.

Product Data:Sizes and Types

Applicable Standards & Reference Documents:

Fire Resistant Ratings:

Submittal Approvals: Job name:

Contractor: Date:

Page 22: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

a division of PABCO building products, LLC "Quality to the Core"

Mold & Water Resistant Core Mold & Water Resistant PaperPABCO® Gypsum Specification PGS-010ASTM specification C 1396

PABCO® MOLD CURB® Plus mold-and-water-resistant gypsum board panels are interior gypsum board panels. This product may be applied in building applications which require direct mechanical attachment to wood or metal wall and ceiling framing, or may attached to existing surfaces using fasteners or adhesives.

PABCO® MOLD CURB® Plus 1/2" thick panels are intended for single layer applications in residential construction. PABCO® MOLD CURB® Plus 5/8" thick type X panels are intended for single or multiple-layer construction in fire-tested assemblies.

Primary Uses:

Mold & Water Resistance:

PABCO® MOLD CURB® Plus panels are manufactured with a special formulated gypsum core and paper facing, which provide enhanced protection against water-and-mold as compared to untreated gypsum board panels. In independent laboratory tests per ASTM D 3273 (Standard Test Method for Resistance to Growth of Mold on the Resistance Surface of Interior Coatings in an Environmental Chamber), PABCO® MOLD CURB® Plus products achieved a 10 rating, the highest level of performance for this test method.

No material may be classified as mold-proof. Prolonged exposure to moisture can result in the growth of mold on any surface. The use of good design, with proper handling and construction practices, is the most effective and best method to minimize mold. This includes avoiding water exposure during all phases of the project, such as: storage, handling, shipping, and product installation and system maintenance both before and after project completion.

Description: PABCO® MOLD CURB® Plus products have been engineered with a mold and water-resistant chemistry that provides the most enhanced mold-and-water-resistant protection available in gypsum board products. The PABCO® MOLD CURB® Plus core is comprised of a fire-resistant, non-combustible gypsum core that is encased in 100% recycled light blue colored face paper and gray liner paper on the back. The paper facings additionally are treated for water and mold-resistance.

The paper facing on the PABCO® MOLD CURB® Plus product affords a surface suitable for decoration. Tapered edges provide a recessed area which allows the taping and filling of joints to create a monolithic wall finish.

Direct exposure to excessive or continuous moisture is to be avoided.

PABCO® MOLD CURB® Plus should not be used in areas subject to constant and/or excessive moisture, and high humidity, such as a tile backer or plastic liner application in tub and shower surrounds, gang showers, saunas, steam rooms or swimming pool enclosures.

When PABCO® MOLD CURB® Plus is used as wallboard, framing spacing and fastening shall be as per section 4 of GA-216 (see “Applicable Standards...” on following page).

PABCO® MOLD CURB® Plus shall not be used where it will be exposed to temperatures exceeding 125° F for an extended period of time.

Submittal 09 29 00

PABCO® Gypsuma division of PABCO® building products, LLCPO Box 405Newark, CA 94560Technical Services: 866-282-9298www.pabcogypsum.com

MOLD CURB® PLUSRegular & Type X

Mold-Water-Resistant Gypsum Wallboard

tothe ®

Limitations:

Page 23: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

Storage & Handling:

Applicable Standards, Codes & Technical Data:

Submittal Approvals:

SJ- ver 06-06-11/MOLD CURB PLUS PABCO® Gypsum

Store all PABCO® gypsum panels flat; do not store on edge as panels are heavy and may fall over causing injury or death. Store in an area that offers protection from adverse weather conditions, condensation, and other forms of moisture. Avoid job site conditions that expose gypsum board to water or moisture. Plastic shipping bags are temporary, and intended for protection during transit only, and must be removed promptly upon arrival. Store gypsum board under protected cover, off the ground with sufficient support to prevent sagging. Exercise proper care to avoid impact, scuffing of the paper faces, undue flexing, and damage to board edges, corners, and ends.

Manufacturing: ASTM C 1396 - Water Resistant Gypsum Backing Board Federal Specification: Federal Specification SS-L-30D T Type VI, Grades X & R*Mold Resistance: ASTM D 3273 Installation: Gypsum Association GA-216; www.gypsum.org ASTM C 840; www.astm.orgFire-Resistant Assemblies: Gypsum Association, GA-600 Fire Resistance Design Manual Underwriters Laboratories, Inc. UL Fire Resistance Directory Surface Burning Characteristics: ASTM E 84; Flame Spread 15; Smoke Developed 0Non-Combustible: ASTM E 136Thermal Resistance “R value”: 1/2" = 0.45; 5/8" = 0.48PABCO Gypsum: “Construction Guide - Fire & Sound Rated Systems”Recycled Content: Refer to PABCO® Sustainable Materials Data Sheet for plant specific details.Foil Application: Foil may NOT be applied to the back of Water Resistant Gypsum Backing Board. See section “Limitations” paragraph #4 above.Please check our website at www.pabcogypsum.com for the latest edition of this specification. * The federal specification for gypsum board, SS-L-30d was withdrawn in 1984. It is provided here for informational purposes only.

Job name:

Contractor: Date:

Product Data, Sizes & Types:

Product UL Core Type Thickness Width Length1 ft Weight2

MOLD CURB® Plus Regular NA 1/2" 48" 8', 12' 1.7 lbs/ft2

MOLD CURB® Plus type X PG-5W 5/8" 48" 8', 12' 2.3 lbs/ft2

Packaging: 2 pieces per bundle, face-to-face, and end labeled.Edge type: TaperedMaterial Safety Data Sheet: MSDS available at www.pabcogypsum.com, Technical Data

PABCO®’s type X products are certified by a third-party inspection service and as evidence of this; each panel bears the Underwriters Laboratories, Inc label for fire resistance, surface burning characteristics and non-combustibility.1 Other lengths may be available on a special order basis. Consult with your local PABCO® representative, or call

PABCO® Technical Assistance.2 Represents approximate weight for design and shipping purposes. A more exact weight may be available for your

area; consult with your local PABCO® representative, or call PABCO® Technical Assistance.

Fire Resistance Rated assembly designs are promulgated from tests performed at IAS* certified independent testing laboratories, and these designs include specific materials assembled in a precise configuration. When choosing construction details to achieve specific fire resistance rated requirements, care must be taken to insure that each component of the specified assembly is the proper one specified in the test report, and assembled in accordance with the specific requirements of the assembly. *(The International Accreditation Service —IAS— is a non-profit, public benefit corporation and a leading accreditation body in the United States. Internationally recognized, accreditation by IAS makes it easier to market products and services both inside and outside the United States.)

Fire Resistant Ratings:

Page #19

Limited Warranty: PABCO® Building Products, LLC, warrants that on the date the gypsum board is shipped from its manufacturing plant the gypsum board is free from defects in materials and manufacture. NOTWITHSTANDING THE FOREGOING, IT IS THE RESPONSIBILITY OF THE GYPSUM BOARD APPLICATOR TO NOTIFY PABCO BUILDING PRODUCTS, LLC, IN WRITING WITHIN TWENTY FOUR (24) HOURS OF DISCOVERY OF ANY VISIBLY DEFECTIVE GYPSUM BOARD PRIOR TO SUCH VISIBLY DEFECTIVE GYPSUM BOARD BEING APPLIED; FAILURE TO DO SO MAY FURTHER LIMIT OR VOID THE RESPONSIBILITIES OF PABCO BUILDING PRODUCTS, LLC, UNDER THIS WARRANTY. This warranty will remain in place for one year from the date of shipment from the manufacturing plant. THIS EXPRESS WARRANTY IS THE EXCLUSIVE WARRANTY PROVIDED BY PABCO® BUILDING PRODUCTS, LLC, AND SUPERSEDES ANY PRIOR, CONTRARY OR ADDITIONAL REPRESENTATIONS, WHETHER ORAL OR WRITTEN. PABCO® BUILDING PRODUCTS, LLC, HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES – WHETHER EXPRESS, IMPLIED, OR STATUTORY – INCLUDING ANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

If the gypsum board fails to conform to the foregoing warranty in Paragraph 1 and such nonconformity is not due to misuse or improper maintenance or storage, Buyer shall notify PABCO® Building Products, LLC, in writing, and within 60 days of discovery, PABCO® Building Products, LLC, shall provide, at its sole and absolute discretion, one of the following: (i) repair or replacement of any nonconforming or defective gypsum wallboard; or (ii) credit or full refund of the purchase price. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER FOR ANY BREACH OF WARRANTY.

IN NO EVENT SHALL PABCO® BUILDING PRODUCTS, LLC, BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, or strict liability in tort or under any other legal theory.

Trademarks: The following trademarks used herein are owned by Pacific Coast Building Products and licensed to PABCO® Gypsum: PABCO®, PABCORE®, FLAME CURB®, WATER CURB®, MOLD CURB®, Quality to the Core®, and ABUSE CURB™. Note: Products described herein may not be available in all geographic markets. Consult your PABCO® Gypsum sales representative for information.

Page 24: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

5/8”

x 1

2’

5/8” x12’

5/8”

x 1

2’

5/8” x 12’

5/8”

x 1

2’

5/8” x 12’

5/8”

x 1

2’

5/8” x 12’

SUPE

R C

PANE

L DE

YES

O F

ABRI

CADO

DE

ACUE

RDO

A L

A NO

RMA

ASTM

C 1

396

- PAN

EL D

E YE

SO P

ARA

SOFI

TO E

XTER

IOR

TIPO

C

PABC

GYP

SUM

, UNA

DIV

ISIÓ

N DE

PAB

CO®

BUIL

DING

PRO

DUCT

S, L

LC N

EWAR

K, C

ALIF

ORN

IA, U

SA 9

4560

PABCO® G

YPSUM, UNA DIVISIÓ

N DE PABCO® BUILDING

PRODUCTS, LLC NEW

ARK, CALIFORNIA, USA 94560

PANEL DE YESO FABRICADO

DE ACUERDO A LA NO

RMA ASTM

C 1396 - PANEL DE YESO PARA SO

FITO EXTERIO

R TIPO C

GYPS

UM B

OARD

MAN

UFAC

TURE

D TO

MEE

T AS

TM C

139

6 - E

XTER

IOR

GYPS

UM S

OFFI

T BO

ARD

TYPE

C

PABC

O® GY

PSUM

, DIV

. OF

PABC

O® BU

ILDI

NG P

RODU

CTS,

LLC

, NEW

ARK,

CA,

945

60 U

SA

PABCO® GYPSUM

, DIV. OF PABCO® BUILDING PRODUCTS, LLC, NEW

ARK, CA, 94560 USA

GYPSUM BOARD M

ANUFACTURED TO MEET ASTM

C 1396 - EXTERIOR GYPSUM SOFFIT BOARD TYPE C

EXTE

RIO

RG

YP

SUM

SO

FFIT

BO

AR

DTY

PE

C

EXTER

IOR

GY

PSU

MS

OFFIT

BO

AR

DTY

PE C

PAN

EL D

E Y

ESO

PA

RA

SO

FITO

EXTE

RIO

RTI

PO

C

PAN

EL DE Y

ESOP

AR

AS

OFITO

EXTER

IOR

TIPO

C

1/2”

x 1

2’

1/2” x 12’1/2” x 12’

1/2”

x 1

2’1/

2” x

12’

1/2” x 12’1/2” x 12’

1/2”

x 1

2’

19673-00

19673-00

19673-00

EXTE

RIO

RG

YP

SUM

SO

FFIT

BO

AR

D

EXTER

IOR

GY

PSU

MS

OFFIT

BO

AR

D

PANE

L DE

YES

O F

ABRI

CADO

DE

ACUE

RDO

A L

A NO

RMA

ASTM

C 1

396

- PAN

EL D

E YE

SO P

ARA

SOFI

TO E

XTER

IOR

PABC

GYP

SUM

, UNA

DIV

ISIÓ

N DE

PAB

CO®

BUIL

DING

PRO

DUCT

S, L

LC N

EWAR

K, C

ALIF

ORN

IA, U

SA 9

4560

PABCO® G

YPSUM, UNA DIVISIÓ

N DE PABCO® BUILDING

PRODUCTS, LLC NEW

ARK, CALIFORNIA, USA 94560

PANEL DE YESO FABRICADO

DE ACUERDO A LA NO

RMA ASTM

C 1396 - PANEL DE YESO PARA SO

FITO EXTERIO

R

GYPS

UM B

OARD

MAN

UFAC

TURE

D TO

MEE

T AS

TM C

139

6 - E

XTER

IOR

GYPS

UM S

OFFI

T BO

ARD

PABC

O® GY

PSUM

, DIV

. OF

PABC

O® BU

ILDI

NG P

RODU

CTS,

LLC

, NEW

ARK,

CA,

945

60 U

SA

PABCO® GYPSUM

, DIV. OF PABCO® BUILDING PRODUCTS, LLC, NEW

ARK, CA, 94560 USA

GYPSUM BOARD M

ANUFACTURED TO MEET ASTM

C 1396 - EXTERIOR GYPSUM SOFFIT BOARD

PAN

EL D

E Y

ESO

PA

RA

SO

FITO

EXTE

RIO

R

PAN

EL DE Y

ESOP

AR

AS

OFITO

EXTER

IOR

"Quality to the Core" R

a division of PABCO® building products, LLC

Description & Primary Uses:

PABCO® Specification PGS-005ASTM specification C 1396Available in MOLD CURB® Plus

PABCO® Gypsum recommends that its Exterior Gypsum Soffit Board application conform to recommendations in GA-216 and ASTM C 840. Panels shall be applied perpendicular to ceiling joists, in a horizontal plane or inclined downward away from the structure in ceiling applications. Panels may be used as a covering on interior wall surfaces. All joints and fasteners not covered by exterior cladding or outer layers in a multi-layer system shall be finished with tape and joint compound.

Unless protected by metal or other water stops, all edges of the soffit board shall be spaced a minimum of 1/4"(inch) away from adjacent vertical surfaces. Suitable fascia and molding shall be provided around the perimeter of the soffit or ceiling to protect the gypsum panels from direct exposure to water.

All soffit board indirectly exposed shall be decorated with an approved exterior cladding or painting system. When PABCO® type X Exterior Gypsum Soffit Board is specified for use in fire rated systems, the UL core type specified and the application method must be as specified in the fire tested system selected.

• PABCO® Exterior Gypsum Soffit Board shall not be subjected to direct exposure to weather, and water.• 24" o.c. (on center) joist spacing is the maximum span for PABCO® type X Exterior Gypsum Soffit Board.• An approved exterior surface decoration (alkyd paint) must be applied to all exposed soffit board. (See TSR: 1338).• All materials and application of PABCO® type X Exterior Gypsum Soffit Board on fire rated assemblies shall be as indicated in the fire test report.• PABCO® Exterior Gypsum Soffit Board Shall not be exposed to sustained temperatures exceeding 125o F (52o C).

• PABCO® Exterior Gypsum Soffit Board is non-structural, and not to be used as a structural fastener base, or to support heavy wall or ceiling mounted objects.

PABCO® Exterior Gypsum Soffit Board is designed for exterior ceiling application on the underside of exterior soffits, open porches, walkways, carport ceilings and similar installations that are completely protected from contact with water. The core and paper has been formulated to enhance its ability to resist sagging when applied in the prescribed manner. PABCO® Exterior Soffit Board panels are manufactured in 1/2" Regular, 1/2" type XXX, 5/8"type X, and 5/8" type C cores. The face paper is cream or light-brown colored with the core type printed in the taper area along the long-edges. The long panel edges are tapered to receive joint treatment.

PABCO® Gypsuma division of PABCO® building products, LLCPO Box 419074Rancho Cordova, CA 95741Technical Services: 866-282-9298www.pabcogypsum.com

Submittal 09 29 00

EXTERIOR SOFFIT BOARD

Regular, Type X, Type C Sag Resistant

tothe ®

Application:

Limitations:

Page 25: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

5/8”

x 1

2’

5/8” x12’

5/8”

x 1

2’

5/8” x 12’

5/8”

x 1

2’

5/8” x 12’

5/8”

x 1

2’

5/8” x 12’

SUPE

R C

PANE

L DE

YES

O F

ABRI

CADO

DE

ACUE

RDO

A L

A NO

RMA

ASTM

C 1

396

- PAN

EL D

E YE

SO P

ARA

SOFI

TO E

XTER

IOR

TIPO

C

PABC

GYP

SUM

, UNA

DIV

ISIÓ

N DE

PAB

CO®

BUIL

DING

PRO

DUCT

S, L

LC N

EWAR

K, C

ALIF

ORN

IA, U

SA 9

4560

PABCO® G

YPSUM, UNA DIVISIÓ

N DE PABCO® BUILDING

PRODUCTS, LLC NEW

ARK, CALIFORNIA, USA 94560

PANEL DE YESO FABRICADO

DE ACUERDO A LA NO

RMA ASTM

C 1396 - PANEL DE YESO PARA SO

FITO EXTERIO

R TIPO C

GYPS

UM B

OARD

MAN

UFAC

TURE

D TO

MEE

T AS

TM C

139

6 - E

XTER

IOR

GYPS

UM S

OFFI

T BO

ARD

TYPE

C

PABC

O® GY

PSUM

, DIV

. OF

PABC

O® BU

ILDI

NG P

RODU

CTS,

LLC

, NEW

ARK,

CA,

945

60 U

SA

PABCO® GYPSUM

, DIV. OF PABCO® BUILDING PRODUCTS, LLC, NEW

ARK, CA, 94560 USA

GYPSUM BOARD M

ANUFACTURED TO MEET ASTM

C 1396 - EXTERIOR GYPSUM SOFFIT BOARD TYPE C

EXTE

RIO

RG

YP

SUM

SO

FFIT

BO

AR

DTY

PE

C

EXTER

IOR

GY

PSU

MS

OFFIT

BO

AR

DTY

PE C

PAN

EL D

E Y

ESO

PA

RA

SO

FITO

EXTE

RIO

RTI

PO

C

PAN

EL DE Y

ESOP

AR

AS

OFITO

EXTER

IOR

TIPO

C

1/2”

x 1

2’

1/2” x 12’1/2” x 12’

1/2”

x 1

2’1/

2” x

12’

1/2” x 12’1/2” x 12’

1/2”

x 1

2’

19673-00

19673-00

19673-00

EXTE

RIO

RG

YP

SUM

SO

FFIT

BO

AR

D

EXTER

IOR

GY

PSU

MS

OFFIT

BO

AR

D

PANE

L DE

YES

O F

ABRI

CADO

DE

ACUE

RDO

A L

A NO

RMA

ASTM

C 1

396

- PAN

EL D

E YE

SO P

ARA

SOFI

TO E

XTER

IOR

PABC

GYP

SUM

, UNA

DIV

ISIÓ

N DE

PAB

CO®

BUIL

DING

PRO

DUCT

S, L

LC N

EWAR

K, C

ALIF

ORN

IA, U

SA 9

4560

PABCO® G

YPSUM, UNA DIVISIÓ

N DE PABCO® BUILDING

PRODUCTS, LLC NEW

ARK, CALIFORNIA, USA 94560

PANEL DE YESO FABRICADO

DE ACUERDO A LA NO

RMA ASTM

C 1396 - PANEL DE YESO PARA SO

FITO EXTERIO

R

GYPS

UM B

OARD

MAN

UFAC

TURE

D TO

MEE

T AS

TM C

139

6 - E

XTER

IOR

GYPS

UM S

OFFI

T BO

ARD

PABC

O® GY

PSUM

, DIV

. OF

PABC

O® BU

ILDI

NG P

RODU

CTS,

LLC

, NEW

ARK,

CA,

945

60 U

SA

PABCO® GYPSUM

, DIV. OF PABCO® BUILDING PRODUCTS, LLC, NEW

ARK, CA, 94560 USA

GYPSUM BOARD M

ANUFACTURED TO MEET ASTM

C 1396 - EXTERIOR GYPSUM SOFFIT BOARD

PAN

EL D

E Y

ESO

PA

RA

SO

FITO

EXTE

RIO

R

PAN

EL DE Y

ESOP

AR

AS

OFITO

EXTER

IOR

SJ 6-06-11/Soffit PABCO® Gypsum

Storage & Handling: Store all PABCO® gypsum panels flat; do not store on edge as panels are heavy and may fall over causing injury or death. Store in an area that offers protection from adverse weather conditions, condensation, and other forms of moisture. Avoid job site conditions that expose gypsum board to water or moisture. Plastic shipping bags are temporary, and intended for protection during transit only, and must be removed promptly upon arrival. Store gypsum board under protected cover, off the ground with sufficient support to prevent sagging. Exercise proper care to avoid impact, scuffing of the paper faces, undue flexing, and damage to board edges, corners, and ends.

Submittal Approvals: Job name:Contractor: Date:

Product UL Core Type Thickness Width Length2 Weight1

Exterior Regular - 1/2" 48" 12' 1.7 lbs/ft2

Exterior Soffit type X PG-3 1/2" 48" 12' 2.0 lbs/ft2

Exterior Soffit type X PG-11 5/8" 48" 8', 12' 2.3 lbs/ft2

Exterior Soffit type C type C 5/8" 48" 8', 12' 2.4 lbs/ft2

Packaging: 2 pieces per bundle, face-to-face, and end tapedEdge type: Tapered1 Represents approximate weight for design and shipping purposes. A more exact weight may be available for your

area; consult with your local PABCO® representative, or call PABCO® Technical Assistance.2 Other lengths may be available on a special order basis. Consult with your local PABCO® representative, or call

PABCO® Technical Assistance.

Product Data,Sizes and Types:

Page #21

Manufacturing: ASTM C 1396; www.astm.org Federal Specification SS-L-30D Type III, Grade X *Installation: Gypsum Association GA-216, www.gypsum.org ASTM C 840, www.astm.orgFire-Resistant Assemblies: Gypsum Association GA-600, Fire Design Manual Underwriters Laboratories, UL Fire Resistance Directory Surface Burning ASTM E 84; www.astm.orgCharacteristics: Flame Spread 15, Smoke Developed 0Non-Combustible: ASTM E 136, www.astm.org

“R” value: 1/2" = 0.45; 5/8" = 0.48 Thermal ResistanceVOC/Asbestos: Free of VOC (Volatile Organic Compound) & asbestosMaterial Safety Data Sheet: MSDS available at www.pabcogypsum.com, Technical DataPABCO Gypsum: “Construction Guide - Fire & Sound Rated Systems”Recycled Content: Refer to PABCO® Sustainable Materials Data Sheet for plant specific details.Please check our website at www.pabcogypsum.com for the latest edition of this specification.

* The federal specification for gypsum board, SS-L-30d was withdrawn in 1984. It is provided here for informational purposes only.

Applicable Standards & Reference Documents:

Fire Resistance Rated assembly designs are promulgated from tests performed at IAS* certified independent testing laboratories, and these designs include specific materials assembled in a precise configuration. When choosing construction details to achieve specific fire resistance rated requirements, care must be taken to insure that each component of the specified assembly is the proper one specified in the test report, and assembled in accordance with the specific requirements of the assembly. *(The International Accreditation Service —IAS— is a non-profit, public benefit corporation and a leading accreditation body in the United States. Internationally recognized, accreditation by IAS makes it easier to market products and services both inside and outside the United States.)

Fire Resistant Ratings:

Limited Warranty: PABCO® Building Products, LLC, warrants that on the date the gypsum board is shipped from its manufacturing plant the gypsum board is free from defects in materials and manufacture. NOTWITHSTANDING THE FOREGOING, IT IS THE RESPONSIBILITY OF THE GYPSUM BOARD APPLICATOR TO NOTIFY PABCO BUILDING PRODUCTS, LLC, IN WRITING WITHIN TWENTY FOUR (24) HOURS OF DISCOVERY OF ANY VISIBLY DEFECTIVE GYPSUM BOARD PRIOR TO SUCH VISIBLY DEFECTIVE GYPSUM BOARD BEING APPLIED; FAILURE TO DO SO MAY FURTHER LIMIT OR VOID THE RESPONSIBILITIES OF PABCO BUILDING PRODUCTS, LLC, UNDER THIS WARRANTY. This warranty will remain in place for one year from the date of shipment from the manufacturing plant. THIS EXPRESS WARRANTY IS THE EXCLUSIVE WARRANTY PROVIDED BY PABCO® BUILDING PRODUCTS, LLC, AND SUPERSEDES ANY PRIOR, CONTRARY OR ADDITIONAL REPRESENTATIONS, WHETHER ORAL OR WRITTEN. PABCO® BUILDING PRODUCTS, LLC, HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES – WHETHER EXPRESS, IMPLIED, OR STATUTORY – INCLUDING ANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

If the gypsum board fails to conform to the foregoing warranty in Paragraph 1 and such nonconformity is not due to misuse or improper maintenance or storage, Buyer shall notify PABCO® Building Products, LLC, in writing, and within 60 days of discovery, PABCO® Building Products, LLC, shall provide, at its sole and absolute discretion, one of the following: (i) repair or replacement of any nonconforming or defective gypsum wallboard; or (ii) credit or full refund of the purchase price. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER FOR ANY BREACH OF WARRANTY.

IN NO EVENT SHALL PABCO® BUILDING PRODUCTS, LLC, BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, or strict liability in tort or under any other legal theory.

Trademarks: The following trademarks used herein are owned by Pacific Coast Building Products and licensed to PABCO® Gypsum: PABCO®, PABCORE®, FLAME CURB®, WATER CURB®, MOLD CURB®, Quality to the Core®, and ABUSE CURB™. Note: Products described herein may not be available in all geographic markets. Consult your PABCO® Gypsum sales representative for information.

Page 26: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

88

88

88

88

"Quality to the Core" R

a division of PABCO® building products, LLC

Description:

PABCO® Gypsum Specification PGS-004ASTM specification C 1396

PABCO® Gypsum Sheathing is a versatile, economical and water-resistant panel product that is used as a substrate for exterior cladding. PABCO® Gypsum Sheathing is designed for mechanical attachment to the outside surface of exterior wall framing using either nails, screws or staples. The core is encased in 100% recycled water-resistant paper facing that is distinguishable by the brown/black coloration on the front and the long edges.

PABCO® type X Gypsum Sheathing is available in a 5/8" Underwriters Laboratories Classified type X water-resistant gypsum core for use in fire-resistant exterior wall assemblies.

PABCO® Gypsum Sheathing: • Shall not be used on ceilings, soffits or sills.• Is designed for mechanical attachment only to the outside surface of the exterior wall

framing using either nails, screws or staples. Construction of fire resistive assemblies shall be in accordance with the construction details specified in the fire test report.

• Is a substrate that shall be covered by exterior wall cladding and is not intended for exposure exceeding 30 days. The gypsum sheathing board shall be covered immediately with a water-resistive barrier if exposure time will be extended or weather conditions become severe.

• Shall be covered with a water-resistive barrier, or horizontal joints shall be sealed; refer to the local building code for details. Where a water-resistive barrier is required, the water-resistive barrier shall be attached over the face of the gypsum sheathing, to the framing, with the upper layer lapped over the lower layer in accordance with the code. (See GA-253 Application of Gypsum Sheathing for complete details, www.gypsum.org).

• Shall be properly flashed at openings and located so that no joint will align with an edge of the opening. Joints shall be staggered.

• Holes and cutouts for pipes or fixtures, or other small openings, shall be properly protected by means such as flashing or caulking.

PABCO® type X Gypsum Sheathing can be used with virtually all exterior walls and cladding: including wood siding, shingles, panel siding, vinyl or metal siding, masonry or brick veneer, Portland cement stucco, and Exterior Insulated Finish Systems (EFIS). Mechanically attached exterior walls and cladding are attached through the sheathing into the wall framing. The performance of any Exterior Insulated Finish System that includes gypsum sheathing and recommendations for the proper method of attachment are the sole responsibility of the Exterior Insulated Finish System manufacturer.”

Primary Uses:

Limitations:

tothe ®

Submittal 06 16 43

GYPSUM SHEATHING

PABCO® Gypsuma division of PABCO® building products, LLCPO Box 417094Rancho Cordova, CA 95741Technical Services: 866-282-9298www.pabcogypsum.com

Page 27: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

88

88

88

88

Page #23

Storage & Handling:

Fire Resistant Ratings:

Applicable Standards and Technical Data:

Submittal Approvals:

SJ- ver 06-06-11/Sheathing PABCO® Gypsum

Store all PABCO® gypsum panels flat; do not store on edge as panels are heavy and may fall over causing injury or death. Store in an area that offers protection from adverse weather conditions, condensa-tion, and other forms of moisture. Avoid job site conditions that expose gypsum board to water or moisture. Plastic shipping bags are temporary, and intended for protection during transit only, and must be removed promptly upon arrival. Store gypsum board under protected cover, off the ground with sufficient support to prevent sagging. Exercise proper care to avoid impact, scuffing of the paper faces, undue flexing, and damage to board edges, corners, and ends.

Manufacturing: ASTM C 1396 Federal Specification SS-L-30D Type II* Installation: Gypsum Association GA-253, GA-254; www.gypsum.org ASTM C 1280; www.astm.orgMold Resistance: ASTM D 3273Surface Burning Characteristics: ASTM E 84, Flame Spread 15, Smoke Developed 0“R” value: 1/2" = 0.45; 5/8" = 0.48 Thermal ResistanceMaterial Safety Data Sheet: MSDS available at www.pabcogypsum.com, Technical DataPABCO Gypsum: “Construction Guide: Fire & Sound Rated Systems”Recycled Content: Refer to PABCO® Sustainable Materials Data Sheet for plant specific details.Please check our website at www.pabcogypsum.com for the latest edition of this specification.* The federal specification for gypsum board, SS-L-30d was withdrawn in 1984. It is provided here for informational purposes only.

Job name:

Contractor: Date:

Product Data,Sizes and Types:

Product UL Core Type Thickness Width Length1 Weight2

Sheathing NA 1/2" 48" 8' 1.7 lbs/ft2

Sheathing Type X PG-5WS 5/8" 48" 8', 12' 2.3 lbs/ft2

Packaging: 2 pieces per bundle, face-to-face, and end labeled.Edge type: Square Edge MSDS: Material Safety Data Sheet available at www.pabcogypsum.com, Technical Data1 Other lengths may be available on a special order basis. Consult with your local PABCO® representative, or call PABCO®

Technical Assistance.2 Represents approximate weight for design and shipping purposes. A more exact weight may be available for your area; consult with

your local PABCO® representative, or call PABCO® Technical Assistance.

Application: PABCO® Gypsum endorses the Gypsum Association’s publication GA-253 and GA-254 as its application documents, which detail instruction on the standard application of wallboard panels (www.gypsum.org).

Fire Resistance Rated assembly designs are promulgated from tests performed at IAS* certified independent testing laboratories, and these designs include specific materials assembled in a precise configuration. When choosing construction details to achieve specific fire resistance rated requirements, care must be taken to insure that each component of the specified assembly is the proper one specified in the test report, and assembled in accordance with the specific requirements of the assembly. *(The International Accreditation Service —IAS— is a non-profit, public benefit corporation and a leading accreditation body in the United States. Internationally recognized, accreditation by IAS makes it easier to market products and services both inside and outside the United States.)

Limited Warranty: PABCO® Building Products, LLC, warrants that on the date the gypsum board is shipped from its manufacturing plant the gypsum board is free from defects in materials and manufacture. NOTWITHSTANDING THE FOREGOING, IT IS THE RESPONSIBILITY OF THE GYPSUM BOARD APPLICATOR TO NOTIFY PABCO BUILDING PRODUCTS, LLC, IN WRITING WITHIN TWENTY FOUR (24) HOURS OF DISCOVERY OF ANY VISIBLY DEFECTIVE GYPSUM BOARD PRIOR TO SUCH VISIBLY DEFECTIVE GYPSUM BOARD BEING APPLIED; FAILURE TO DO SO MAY FURTHER LIMIT OR VOID THE RESPONSIBILITIES OF PABCO BUILDING PRODUCTS, LLC, UNDER THIS WARRANTY. This warranty will remain in place for one year from the date of shipment from the manufacturing plant. THIS EXPRESS WARRANTY IS THE EXCLUSIVE WARRANTY PROVIDED BY PABCO® BUILDING PRODUCTS, LLC, AND SUPERSEDES ANY PRIOR, CONTRARY OR ADDITIONAL REPRESENTATIONS, WHETHER ORAL OR WRITTEN. PABCO® BUILDING PRODUCTS, LLC, HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES – WHETHER EXPRESS, IMPLIED, OR STATUTORY – INCLUDING ANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

If the gypsum board fails to conform to the foregoing warranty in Paragraph 1 and such nonconformity is not due to misuse or improper maintenance or storage, Buyer shall notify PABCO® Building Products, LLC, in writing, and within 60 days of discovery, PABCO® Building Products, LLC, shall provide, at its sole and absolute discretion, one of the following: (i) repair or replacement of any nonconforming or defective gypsum wallboard; or (ii) credit or full refund of the purchase price. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER FOR ANY BREACH OF WARRANTY.

IN NO EVENT SHALL PABCO® BUILDING PRODUCTS, LLC, BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, or strict liability in tort or under any other legal theory.

Trademarks: The following trademarks used herein are owned by Pacific Coast Building Products and licensed to PABCO® Gypsum: PABCO®, PABCORE®, FLAME CURB®, WATER CURB®, MOLD CURB®, Quality to the Core®, and ABUSE CURB™. Note: Products described herein may not be available in all geographic markets. Consult your PABCO® Gypsum sales representative for information.

Page 28: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

"Quality to the Core" R

a division of PABCO® building products, LLC

tothe ®PABCO® Gypsum Specification PGS-008

ASTM specification C 1396

Limitations: • Shaftwall/Stairwell systems are designed as nonload bearing. (NLB)• Do not install in areas which will be adjacent to occupancies of unusually high moisture conditions.• Where penetrations occur in the assembly, additional reinforcement at corners may be required to distribute stress; approved flexible sealant/caulking may be required to seal around some penetrations. • Through penetrations are not allowed in area separation fire walls that are designed to collapse on the fire side.• Not recommended for use as an unlined HVAC supply shaft or duct.• Limiting heights and deflection criteria must be based upon the metal stud manufacturer’s recommendations.

PABCORE® SHAFTLINER type X panels are manufactured with a proprietary fire resistant type X core which has been reinforced with glass fibers and speciality additives to increase its fire-resistance. This core is encased in 100% recycled water-resistant face and back paper, and features a double beveled edge for ease of installation.

PABCORE® SHAFTLINER type X is distinguishable by the light green coloration of the water-resistant paper facing.

PABCORE® SHAFTLINER type X panels are designed for lining elevator, ventilation, and utility shafts, as well as constructing lightweight sound attenuation fire-resistant cavity shaft walls, and area separation fire walls in multifamily dwellings such as townhouses, condominiums, and apartments.

These panels are key components in PABCO® Shaftwall and Area Separation Fire Wall (ASFW) Systems utilizing C-H, C-T Studs or H-Studs. PABCO® Shaftwall Systems are easy to erect, achieving fire-resistance ratings of one and two hours. Both solid and cavity-type area separation walls provide Sound Transmission Class (STC) ratings that exceed model building code requirements with designs that achieve STC ratings in excess of 60.

Area Separation Fire Wall assemblies are light weight, weighing no more than 10 lbs/ft2 when constructed. As a result, the need for costly footings or foundation modifications are often eliminated. Due to the relatively light weight panels, they can be installed up to four (4) stories in height.

When used as an area separation wall, the system must be: • Continuous from the foundation to the underside of the protected roof sheathing or continue through the roof to form a parapet.

• Designed to allow for collapse of the construction on the side of the wall exposed to fire without collapse of the area separation fire wall.

Submittal 09 29 00

Page #24

PABCORE® SHAFTLINER

PABCO® Gypsuma division of PABCO® building products, LLCPO Box 419074Rancho Cordova, CA 95741Technical Services: 866-282-9298www.pabcogypsum.com

Description:

Primary Uses:

Page 29: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

PABCORE® SHAFTLINER type X and PABCORE® MOLD CURB® Plus SHAFTLINER type X panels may be used in one and two-hour shaftwall systems, one and two-hour horizontal corridor ceiling systems and two-hour Area Separation Walls. Refer to the PABCO® Gypsum Shaftwall Systems publication for details.

Applicable Standards, Codes & Technical Data:

Submittal Approvals:

SJ 6-14-11/Shaftliner PABCO® Gypsum

Application:

Storage & Handling: Store all PABCO® gypsum panels flat; do not store on edge as panels are heavy and may fall over causing injury or death. Store in an area that offers protection from adverse weather conditions, condensation, and other forms of moisture. Avoid job site conditions that expose gypsum board to water or moisture. Plastic shipping bags are temporary, and intended for protection during transit only, and must be removed promptly upon arrival. Store gypsum board under protected cover, off the ground with sufficient support to prevent sagging. Exercise proper care to avoid impact, scuffing of the paper faces, undue flexing, and damage to board edges, corners, and ends.

Product Data,Sizes and Types:

Job name:

Contractor Date:

UL Core Type Thickness Width Length1 Edge Type Weight2

PG-10 1 inch 24 inches 8', 10',12' Double beveled 4.4 lbs/ft2

PABCORE® SHAFTLINER products are certified by a third-party inspection service. Each panel bears the UNDERWRITERS LABORATORIES, Inc. label to indicate CERTIFICATION of fire resistance, surface burning characteristics, and non-combustibility.1 Other lengths may be available on a special order basis. Consult with your local PABCO® representative, or call

PABCO® Technical Assistance.2 Represents approximate weight for design and shipping purposes. A more exact weight may be available for your

area; consult with your local PABCO® representative, or call PABCO® Technical Assistance.

Page #25

Manufacturing: ASTM C 1396; www.astm.org Federal Specification Type IV, Grade X*Installation: Gypsum Association GA-216, www.gypsum.org ASTM C 840, www.astm.orgFire-Resistant Assemblies: Gypsum Association GA-600, Fire Design Manual Underwriters Laboratories, UL Fire Resistance Directory Surface Burning ASTM E 84; UL: Fire Resistance DirectoryCharacteristics: Flame Spread 15, Smoke Developed 0Non-Combustible: ASTM E 136, www.astm.org

“R” value: 0.83 Thermal ResistanceVOC/Asbestos: Free of VOC (Volatile Organic Compound) & asbestosMaterial Safety Data Sheet: MSDS available at www.pabcogypsum.com, Technical DataPABCO Gypsum: “Construction Guide - Fire & Sound Rated Systems”Recycled Content: Refer to PABCO® Sustainable Materials Data Sheet for plant specific details.Please check our website at www.pabcogypsum.com for the latest edition of this specification.

* The federal specification for gypsum board, SS-L-30d was withdrawn in 1984. It is provided here for informational purposes only.

Fire Resistance Rated assembly designs are promulgated from tests performed at IAS* certified independent testing laboratories, and these designs include specific materials assembled in a precise configuration. When choosing construction details to achieve specific fire resistance rated requirements, care must be taken to insure that each component of the specified assembly is the proper one specified in the test report, and assembled in accordance with the specific requirements of the assembly. *(The International Accreditation Service —IAS— is a non-profit, public benefit corporation and a leading accreditation body in the United States. Internationally recognized, accreditation by IAS makes it easier to market products and services both inside and outside the United States.)

Fire Resistant Ratings:

Limited Warranty: PABCO® Building Products, LLC, warrants that on the date the gypsum board is shipped from its manufacturing plant the gypsum board is free from defects in materials and manufacture. NOTWITHSTANDING THE FOREGOING, IT IS THE RESPONSIBILITY OF THE GYPSUM BOARD APPLICATOR TO NOTIFY PABCO BUILDING PRODUCTS, LLC, IN WRITING WITHIN TWENTY FOUR (24) HOURS OF DISCOVERY OF ANY VISIBLY DEFECTIVE GYPSUM BOARD PRIOR TO SUCH VISIBLY DEFECTIVE GYPSUM BOARD BEING APPLIED; FAILURE TO DO SO MAY FURTHER LIMIT OR VOID THE RESPONSIBILITIES OF PABCO BUILDING PRODUCTS, LLC, UNDER THIS WARRANTY. This warranty will remain in place for one year from the date of shipment from the manufacturing plant. THIS EXPRESS WARRANTY IS THE EXCLUSIVE WARRANTY PROVIDED BY PABCO® BUILDING PRODUCTS, LLC, AND SUPERSEDES ANY PRIOR, CONTRARY OR ADDITIONAL REPRESENTATIONS, WHETHER ORAL OR WRITTEN. PABCO® BUILDING PRODUCTS, LLC, HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES – WHETHER EXPRESS, IMPLIED, OR STATUTORY – INCLUDING ANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

If the gypsum board fails to conform to the foregoing warranty in Paragraph 1 and such nonconformity is not due to misuse or improper maintenance or storage, Buyer shall notify PABCO® Building Products, LLC, in writing, and within 60 days of discovery, PABCO® Building Products, LLC, shall provide, at its sole and absolute discretion, one of the following: (i) repair or replacement of any nonconforming or defective gypsum wallboard; or (ii) credit or full refund of the purchase price. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER FOR ANY BREACH OF WARRANTY.

IN NO EVENT SHALL PABCO® BUILDING PRODUCTS, LLC, BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, or strict liability in tort or under any other legal theory.

Trademarks: The following trademarks used herein are owned by Pacific Coast Building Products and licensed to PABCO® Gypsum: PABCO®, PABCORE®, FLAME CURB®, WATER CURB®, MOLD CURB®, Quality to the Core®, and ABUSE CURB™. Note: Products described herein may not be available in all geographic markets. Consult your PABCO® Gypsum sales representative for information.

Page 30: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

"Quality to the Core" R

a division of PABCO® building products, LLC

tothe ®PABCO® Gypsum Specification PGS-008

ASTM specification C 1396

Limitations: • Shaftwall/Stairwell systems are designed as nonload bearing. (NLB)• Do not install in areas which will be adjacent to occupancies of unusually high moisture conditions.• Where penetrations occur in the assembly, additional reinforcement at corners may be required to distribute stress; approved flexible sealant/caulking may be required to seal around some penetrations. • Through penetrations are not allowed in area separation fire walls that are designed to collapse on the fire side.• Not recommended for use as an unlined HVAC supply shaft or duct.• Limiting heights and deflection criteria must be based upon the metal stud manufacturer’s recommendations.

PABCORE® MOLD CURB® Plus SHAFTLINER type X panels are manufactured with a proprietary fire resistant type X core which has been reinforced with glass fibers and speciality additives to increase its fire-resistance. This core is encased in 100% recycled water-resistant face and back paper, and features a double beveled edge for ease of installation.PABCORE® MOLD CURB® Plus SHAFTLINER type X panels are manufactured with the performance criteria described above, however, in addition, the core and paper facings have been chemically treated for enhanced protection to resist water and mold. This product is distinguishable by the light blue coloration of the paper.

PABCORE® MOLD CURB® Plus SHAFTLINER type X panels are designed for lining elevator, ventilation, and utility shafts, as well as constructing lightweight sound attenuation fire-resistant cavity shaft walls, and area separation fire walls in multifamily dwellings such as townhouses, condominiums, and apartments.These panels are key components in PABCO® Shaftwall and Area Separation Fire Wall (ASFW) Systems utilizing C-H, C-T Studs or H-Studs. PABCO® Shaftwall Systems are easy to erect, achieving fire-resistance ratings of one and two hours. Both solid and cavity-type area separation walls provide Sound Transmission Class (STC) ratings that exceed model building code requirements with designs that achieve STC ratings in excess of 60. Area Separation Fire Wall assemblies are light weight, weighing no more than 10 lbs/ft2 when constructed. As a result, the need for costly footings or foundation modifications are often eliminated. Due to the relatively light weight panels, they can be installed up to four (4) stories in height.When used as an area separation wall, the system must be: • Continuous from the foundation to the underside of the protected roof sheathing or continue through the roof to form a parapet.

• Designed to allow for collapse of the construction on the side of the wall exposed to fire without collapse of the area separation fire wall.

Submittal 09 29 00

Page #26

PABCORE® MOLD CURB®PLUS

SHAFTLINERPABCO® Gypsuma division of PABCO® building products, LLCPO Box 419074Rancho Cordova, CA 95741Technical Services: 866-282-9298www.pabcogypsum.com

Description:

Primary Uses:

Page 31: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

PABCORE® MOLD CURB® Plus SHAFTLINER type X panels additionally provide resistance against water and mold due to chemical treatment of the paper facings and the gypsum core, as compared to untreated gypsum board panels. In independent laboratory tests per ASTM D 3273 (Standard Test Method for Resistance to Growth of Mold on the Resistance Surface of Interior Coatings in an Environmental Chamber), PABCO® MOLD CURB® Plus products achieved a 10 rating, the highest level of performance for this test method.No material may be classified as mold-proof. Prolonged exposure to moisture can result in the growth of mold on any surface. The use of good design, with proper handling and construction practices, is the most effective and best method to minimize mold. This includes avoiding water exposure during all phases of the project, such as: storage, handling, shipping, and product installation and system maintenance both before and after project completion.

PABCORE® MOLD CURB® Plus SHAFTLINER type X panels may be used in one and two-hour shaftwall systems, one and two-hour horizontal corridor ceiling systems and two-hour Area Separation Walls. Refer to the PABCO® Gypsum Shaftwall Systems publication for details.

Mold & Water Resistance:

Applicable Standards, Codes & Technical Data:

Submittal Approvals:

SJ 06-14-11/Shaftliner MCPlus PABCO® Gypsum

Application:

Storage & Handling: Store all PABCO® gypsum panels flat; do not store on edge as panels are heavy and may fall over causing injury or death. Store in an area that offers protection from adverse weather conditions, condensation, and other forms of moisture. Avoid job site conditions that expose gypsum board to water or moisture. Plastic shipping bags are temporary, and intended for protection during transit only, and must be removed promptly upon arrival. Store gypsum board under protected cover, off the ground with sufficient support to prevent sagging. Exercise proper care to avoid impact, scuffing of the paper faces, undue flexing, and damage to board edges, corners, and ends.

Product Data,Sizes and Types:

Job name:

Contractor Date:

UL Core Type Thickness Width Length1 Edge Type Weight2

PG-10 1 inch 24 inches 8', 10',12' Double beveled 4.4 lbs/ft2

PABCORE® SHAFTLINER products are certified by a third-party inspection service. Each panel bears the UNDERWRITERS LABORATORIES, Inc. label to indicate CERTIFICATION of fire resistance, surface burning characteristics, and non-combustibility.1 Other lengths may be available on a special order basis. Consult with your local PABCO® representative, or call

PABCO® Technical Assistance.2 Represents approximate weight for design and shipping purposes. A more exact weight may be available for your

area; consult with your local PABCO® representative, or call PABCO® Technical Assistance.

Page #27

Manufacturing: ASTM C 1396; www.astm.org Federal Specification Type IV, Grade X*Mold Resistance: ASTM D3273; www.astm.orgInstallation: Gypsum Association GA-216, www.gypsum.org ASTM C 840, www.astm.orgFire-Resistant Assemblies: Gypsum Association GA-600, Fire Design Manual Underwriters Laboratories, UL Fire Resistance Directory Surface Burning ASTM E 84; UL: Fire Resistance DirectoryCharacteristics: Flame Spread 15, Smoke Developed 0Non-Combustible: ASTM E 136, www.astm.org

“R” value: 0.83 Thermal ResistanceVOC/Asbestos: Free of VOC (Volatile Organic Compound) & asbestosMaterial Safety Data Sheet: MSDS available at www.pabcogypsum.com, Technical DataPABCO Gypsum: “Construction Guide - Fire & Sound Rated Systems”Recycled Content: Refer to PABCO® Sustainable Materials Data Sheet for plant specific details.Please check our website at www.pabcogypsum.com for the latest edition of this specification.

* The federal specification for gypsum board, SS-L-30d was withdrawn in 1984. It is provided here for informational purposes only.

Fire Resistance Rated assembly designs are promulgated from tests performed at IAS* certified independent testing laboratories, and these designs include specific materials assembled in a precise configuration. When choosing construction details to achieve specific fire resistance rated requirements, care must be taken to insure that each component of the specified assembly is the proper one specified in the test report, and assembled in accordance with the specific requirements of the assembly. *(The International Accreditation Service —IAS— is a non-profit, public benefit corporation and a leading accreditation body in the United States. Internationally recognized, accreditation by IAS makes it easier to market products and services both inside and outside the United States.)

Fire Resistant Ratings:

Limited Warranty: PABCO® Building Products, LLC, warrants that on the date the gypsum board is shipped from its manufacturing plant the gypsum board is free from defects in materials and manufacture. NOTWITHSTANDING THE FOREGOING, IT IS THE RESPONSIBILITY OF THE GYPSUM BOARD APPLICATOR TO NOTIFY PABCO BUILDING PRODUCTS, LLC, IN WRITING WITHIN TWENTY FOUR (24) HOURS OF DISCOVERY OF ANY VISIBLY DEFECTIVE GYPSUM BOARD PRIOR TO SUCH VISIBLY DEFECTIVE GYPSUM BOARD BEING APPLIED; FAILURE TO DO SO MAY FURTHER LIMIT OR VOID THE RESPONSIBILITIES OF PABCO BUILDING PRODUCTS, LLC, UNDER THIS WARRANTY. This warranty will remain in place for one year from the date of shipment from the manufacturing plant. THIS EXPRESS WARRANTY IS THE EXCLUSIVE WARRANTY PROVIDED BY PABCO® BUILDING PRODUCTS, LLC, AND SUPERSEDES ANY PRIOR, CONTRARY OR ADDITIONAL REPRESENTATIONS, WHETHER ORAL OR WRITTEN. PABCO® BUILDING PRODUCTS, LLC, HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES – WHETHER EXPRESS, IMPLIED, OR STATUTORY – INCLUDING ANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

If the gypsum board fails to conform to the foregoing warranty in Paragraph 1 and such nonconformity is not due to misuse or improper maintenance or storage, Buyer shall notify PABCO® Building Products, LLC, in writing, and within 60 days of discovery, PABCO® Building Products, LLC, shall provide, at its sole and absolute discretion, one of the following: (i) repair or replacement of any nonconforming or defective gypsum wallboard; or (ii) credit or full refund of the purchase price. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER FOR ANY BREACH OF WARRANTY.

IN NO EVENT SHALL PABCO® BUILDING PRODUCTS, LLC, BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, or strict liability in tort or under any other legal theory.

Trademarks: The following trademarks used herein are owned by Pacific Coast Building Products and licensed to PABCO® Gypsum: PABCO®, PABCORE®, FLAME CURB®, WATER CURB®, MOLD CURB®, Quality to the Core®, and ABUSE CURB™. Note: Products described herein may not be available in all geographic markets. Consult your PABCO® Gypsum sales representative for information.

Page 32: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

"Quality to the Core" R

a division of PABCO® building products, LLC

Description & Primary Uses:

PABCO® Gypsum Ceiling Board is a 1/2" thick gypsum panel specifically formulated and designed for ceiling application where joist spacing is a maximum of 24"on center. PABCO® Gypsum Ceiling Board is manufactured with a sag-resistant engineered core to allow for the application of a water-based texture material when the 1/2" ceiling board is installed on 24" on-center framing. When tested using the ASTM C 473 humidified deflection test, deflection shall not exceed 50% of the allowable deflection specified for 5/8" thick panels.

PABCO® Gypsum Ceiling Board is manufactured with a dimensionally stable, noncombustible fire-resistant gypsum core, encased in 100% recycled paper, designed to receive joint treatment, paint, wall covering, or textured coatings. The face paper is folded around the long edges to reinforce as well as to protect the core, and affords a surface suitable for decoration. The panel ends are cut square. The long panel edges are tapered, allowing a recessed joint area to be reinforced and concealed to create a monolithic wall or ceiling finish.

PABCO® Gypsum Ceiling Board is available in 1/2" thickness, 4 feet wide, 12 and 14 feet long panels, with tapered edges. A Round Edge (RE) profile is available to meet specific joint treatment requirements.

PABCO® Gypsum recommends that its Gypsum Ceiling Board be applied and finished to comply with recommendations in GA-216 and/or ASTM C 840 in a manner similar to PABCO® Gypsum Wallboard. Panels shall be applied perpendicular to ceiling framing 24"on center maximum.

Application:

• Maximum spacing between ceiling supports not to exceed 24" on center.• PABCO® Gypsum Ceiling Board is intended for interior applications only, and

shall not be used where there will be direct exposure to water or continuous high humidity before, during, and after construction.

• Avoid exposure to temperatures exceeding 125 oF (52 oC) for an extended period of time.

• PABCO® Gypsum Ceiling Board is a non-structural panel, not to be used as a structural fastener base or to support heavy wall or ceiling mounted objects.

• PABCO® Gypsum Ceiling Board shall be primed and sealed with a high-solids latex primer before the application of texture, or before final decoration. Adequate ventilation is necessary when applying texture to this product.

• Insulation weight must not exceed 2 lbs/sf.

Limitations:

Page #28

Submittal 09 29 00

INTERIOR CEILING BOARD

Sag-Resistant, TE & RE

tothe ®PABCO® Gypsum Specification PGS-006

ASTM specification C 1396Available in MOLD CURB® Plus

PABCO® Gypsuma division of PABCO® building products, LLCPO Box 419074Rancho Cordova, CA 95741Technical Services: 866-282-9298www.pabcogypsum.com

Page 33: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

SJ 06-06-11/Ceiling Bd PABCO® Gypsum

Storage & Handling: Store all PABCO© gypsum panels flat; do not store on edge as panels are heavy and may fall over causing injury or death. Store in an area that offers protection from adverse weather conditions, condensation, and other forms of moisture. Avoid job site conditions that expose gypsum board to water or moisture. Plastic shipping bags are temporary, and intended for protection during transit only, and must be removed promptly upon arrival. Store gypsum board under protected cover, off the ground with sufficient support to prevent sagging. Exercise proper care to avoid impact, scuffing of the paper faces, undue flexing, and damage to board edges, corners, and ends.

Applicable Standards and Technical Data:

Manufacturing: ASTM C 1396, C 1395, C 475, C840; www astm.org Federal Specification SS-L-30D Type III*Installation: Gypsum Association GA-216, GA-214 www.gypsum.org ASTM C 840, www.astm.orgSurface Burning ASTM E 84Characteristics: Flame Spread 15, Smoke Developed 0Noncombustible: ASTM E 136“R value”: 1/2" = 0.45 Thermal ResistanceVOC/Asbestos: Free of VOC (Volatile Organic Compound) & asbestosRecycled Content: Refer to PABCO® Sustainable Materials Data Sheet for plant specific details.PABCO® Gypsum: “Construction Guide - Fire & Sound Rated Systems”ICC - ESR 1338Please check our website at www.pabcogypsum.com for the latest edition of this specification. * The federal specification for gypsum board, SS-L-30d was withdrawn in 1984. It is provided here for

informational purposes only.

Submittal Approvals: Job name:Contractor: Date:

Page #29

Product Data:

Packaging: 2 panels per bundle, face-to-face, and end labeled. Edge Type: Tapered Edge (TE), or Round Edge (RE). Material Safety Data Sheet: MSDS available at www.pabcogypsum.com, Technical Data1 Represents approximate weight for design and shipping purposes. A more exact weight may be available

for your area; consult with your local PABCO® representative, or call PABCO® Technical Assistance.2 Other lengths may be available on a special order basis. Consult with your local PABCO®

representative, or call PABCO® Technical Assistance.

Product UL Core Type Thickness Width Length2 Weight1

Ceiling Board NA 1/2" 48" 12', 14' 1.8 lbs/ft2

Limited Warranty: PABCO® Building Products, LLC, warrants that on the date the gypsum board is shipped from its manufacturing plant the gypsum board is free from defects in materials and manufacture. NOTWITHSTANDING THE FOREGOING, IT IS THE RESPONSIBILITY OF THE GYPSUM BOARD APPLICATOR TO NOTIFY PABCO BUILDING PRODUCTS, LLC, IN WRITING WITHIN TWENTY FOUR (24) HOURS OF DISCOVERY OF ANY VISIBLY DEFECTIVE GYPSUM BOARD PRIOR TO SUCH VISIBLY DEFECTIVE GYPSUM BOARD BEING APPLIED; FAILURE TO DO SO MAY FURTHER LIMIT OR VOID THE RESPONSIBILITIES OF PABCO BUILDING PRODUCTS, LLC, UNDER THIS WARRANTY. This warranty will remain in place for one year from the date of shipment from the manufacturing plant. THIS EXPRESS WARRANTY IS THE EXCLUSIVE WARRANTY PROVIDED BY PABCO® BUILDING PRODUCTS, LLC, AND SUPERSEDES ANY PRIOR, CONTRARY OR ADDITIONAL REPRESENTATIONS, WHETHER ORAL OR WRITTEN. PABCO® BUILDING PRODUCTS, LLC, HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES – WHETHER EXPRESS, IMPLIED, OR STATUTORY – INCLUDING ANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

If the gypsum board fails to conform to the foregoing warranty in Paragraph 1 and such nonconformity is not due to misuse or improper maintenance or storage, Buyer shall notify PABCO® Building Products, LLC, in writing, and within 60 days of discovery, PABCO® Building Products, LLC, shall provide, at its sole and absolute discretion, one of the following: (i) repair or replacement of any nonconforming or defective gypsum wallboard; or (ii) credit or full refund of the purchase price. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER FOR ANY BREACH OF WARRANTY.

IN NO EVENT SHALL PABCO® BUILDING PRODUCTS, LLC, BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, or strict liability in tort or under any other legal theory.

Trademarks: The following trademarks used herein are owned by Pacific Coast Building Products and licensed to PABCO® Gypsum: PABCO®, PABCORE®, FLAME CURB®, WATER CURB®, MOLD CURB®, Quality to the Core®, and ABUSE CURB™. Note: Products described herein may not be available in all geographic markets. Consult your PABCO® Gypsum sales representative for information.

Page 34: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

tothe ®

Page #30

"Quality to the Core" R

a division of PABCO® building products, LLC

Description: PABCO® Regular Gypsum Wallboard is an interior gypsum board product with a fire-resistant, dimensionally stable, gypsum core. Each panel is encased in a 100% recycled paper on the face and back sides. The face paper is folded around the long edges to reinforce and protect the core; the ends are square cut and finished smooth. Long edges of panels are tapered providing a recessed area that allows joints to be reinforced and concealed with joint treatment creating a monolithic wall finish. High quality face paper manufactured by PABCO® Paper provides a smooth surface which can be decorated with paint, texture or wallpaper.

Primary Uses: PABCO® Regular Gypsum Wallboard products are utilized in non-structural wall, ceiling and partition applications, for use in new construction or renovation work. Both may also be used as a covering material for flat or curved surfaces.

Draft version B2 6-10-08

Reg SJones

Submittal 09 29 00

REGULARGypsum Wallboard

PABCO® Gypsum Specification PGS-001ASTM specification C 1396Available in MOLD CURB® Plus

PABCO® Gypsuma division of PABCO® building products, LLCPO Box 419074Rancho Cordova, CA 95741Technical Services: 866-282-9298www.pabcogypsum.com

PABCO® Gypsum endorses the Gypsum Association’s publications GA-216 and GA-214 as well as ASTM Standard Specification C 840 as its application and finishing specifications. These similar specifications give detailed instruction on the standard application of wallboard panels and proper joint finishing procedures. PABCO® Gypsum Wallboard panels may be attached to wood or steel framing with nails, screws and/or adhesives. Finishing of joints and covering fasteners is detailed in GA 214 and/or ASTM C 840.

A combination of nails on the perimeters and screws in the field of panels is permitted with the spacing the same as described for each type fastener. PABCO® Gypsum Wallboard panels shall be “cut to fit” as closely as possible without forcing panels in place. PABCO® Gypsum Wallboard joints shall not be aligned with door or window openings; joints shall be offset at least 6”. Temperature at time of panel application shall be above 40 degrees F and shall be maintained at 50 degrees F 48 hours prior to and during application and drying of joint compound. Special treatment of assemblies for additions such as control joints, resilient channel, insulation and perimeter relief systems shall be as specified in the tested system.

Application:

Advantages: • Cost efficient, lightweight, and non-combustible core.• Accepts a wide range of decorative finishes.• Consistent edge tapers produce a monolithic flat surface.• Easily cut, permitting quick installation, painting and/or decorating.• Negligible expansion and contraction under normal atmospheric changes.

Limitations: PABCO® Regular Gypsum Wallboard panels are intended for interior applications and shall not be used where there will be direct exposure to water or continuous high humidity before, during, and/or after construction. Gypsum panel products shall not be exposed to sustained temperatures exceeding 125o F (52o C).

PABCO® Regular Gypsum Wallboard panels are non-structural, not to be used as a structural fastener base, or to support heavy wall or ceiling mounted objects. Installation to walls shall be with the bottom edge spaced a minimum of 1/4" inch (6 mm) above the floor.

Page 35: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

Page #31 SJ-06-06-11/Regular PABCO® Gypsum

Storage & Handling: Store all PABCO® gypsum panels flat; do not store on edge as panels are heavy and may fall over causing injury or death. Store in an area that offers protection from adverse weather conditions, condensation, and other forms of moisture. Avoid job site conditions that expose gypsum board to water or moisture. Plastic shipping bags are temporary, and intended for protection during transit only, and must be removed promptly upon arrival. Store gypsum board under protected cover, off the ground with sufficient support to prevent sagging. Exercise proper care to avoid impact, scuffing of the paper faces, undue flexing, and damage to board edges, corners, and ends.

Submittal Approvals: Job name:Contractor: Date:

Applicable Standards and Technical Data:

Manufacturing: ASTM C 1396 Federal Specification SS-L-30D Type III & Type VII *Installation: Gypsum Association GA-214 & GA-216, www.gypsum.org ASTM C 840, www.astm.orgSurface Burning ASTM E 84Characteristics: Flame Spread 15, Smoke Developed 0Noncombustible: ASTM E 136“R” value: 1/2" = 0.45; 3/8" = 0.32 Thermal ResistanceVOC/Asbestos: Free of VOC (Volatile Organic Compound) & asbestosPABCO Gypsum: “Construction Guide - Fire & Sound Rated Systems”Foil Application: Foil may be applied to the back of ASTM C 1396 gypsum wallboard for the purpose of complying with ASTM C 1396 paragraph 5.1.Recycled Content: Refer to PABCO® Sustainable Materials Data Sheet for plant specific details.Please check our website at www.pabcogypsum.com for the latest edition of this specification. * The federal specification for gypsum board, SS-L-30d was withdrawn in 1984. It is provided here for informational purposes only.

Product Data:Sizes and Types

Core Thickness Width Length1 Weight2

Regular 1/4" 48" 8' 1.2 lbs/ft2

Regular 3/8" 48" 8' 1.5 lbs/ft2

Regular 1/2" 48" 8', 9', 10', 12', 14', 15' 1.6 lbs/ft2

Regular 1/2" 54" 10', 12' 1.6 lbs/ft2

Packaging: 2 pieces per bundle, face-to-face, and end labeled. Edge type: Tapered Material Safety Data Sheet: MSDS available at www.pabcogypsum.com, Technical Data1 Other lengths may be available on a special order basis. Consult with your local PABCO®

representative, or call PABCO® Technical Assistance.2 Represents approximate weight for design and shipping purposes. A more exact weight may be available

for your area; consult with your local PABCO® representative, or call PABCO® Technical Assistance.

Limited Warranty: PABCO® Building Products, LLC, warrants that on the date the gypsum board is shipped from its manufacturing plant the gypsum board is free from defects in materials and manufacture. NOTWITHSTANDING THE FOREGOING, IT IS THE RESPONSIBILITY OF THE GYPSUM BOARD APPLICATOR TO NOTIFY PABCO BUILDING PRODUCTS, LLC, IN WRITING WITHIN TWENTY FOUR (24) HOURS OF DISCOVERY OF ANY VISIBLY DEFECTIVE GYPSUM BOARD PRIOR TO SUCH VISIBLY DEFECTIVE GYPSUM BOARD BEING APPLIED; FAILURE TO DO SO MAY FURTHER LIMIT OR VOID THE RESPONSIBILITIES OF PABCO BUILDING PRODUCTS, LLC, UNDER THIS WARRANTY. This warranty will remain in place for one year from the date of shipment from the manufacturing plant. THIS EXPRESS WARRANTY IS THE EXCLUSIVE WARRANTY PROVIDED BY PABCO® BUILDING PRODUCTS, LLC, AND SUPERSEDES ANY PRIOR, CONTRARY OR ADDITIONAL REPRESENTATIONS, WHETHER ORAL OR WRITTEN. PABCO® BUILDING PRODUCTS, LLC, HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES – WHETHER EXPRESS, IMPLIED, OR STATUTORY – INCLUDING ANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

If the gypsum board fails to conform to the foregoing warranty in Paragraph 1 and such nonconformity is not due to misuse or improper maintenance or storage, Buyer shall notify PABCO® Building Products, LLC, in writing, and within 60 days of discovery, PABCO® Building Products, LLC, shall provide, at its sole and absolute discretion, one of the following: (i) repair or replacement of any nonconforming or defective gypsum wallboard; or (ii) credit or full refund of the purchase price. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER FOR ANY BREACH OF WARRANTY.

IN NO EVENT SHALL PABCO® BUILDING PRODUCTS, LLC, BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, or strict liability in tort or under any other legal theory.

Trademarks: The following trademarks used herein are owned by Pacific Coast Building Products and licensed to PABCO® Gypsum: PABCO®, PABCORE®, FLAME CURB®, WATER CURB®, MOLD CURB®, Quality to the Core®, and ABUSE CURB™. Note: Products described herein may not be available in all geographic markets. Consult your PABCO® Gypsum sales representative for information.

Page 36: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

WATER

CURB®

TYPE X

WAT

ER C

URB

®TY

PE X

WATER

CURB®

TYPE X

WAT

ER C

URB

®TY

PE X

WATER

CURB®

TYPE X

WAT

ER C

URB

®TY

PE X

WATER

CURB®

TYPE X

WAT

ER C

URB

®TY

PE X

"Quality to the Core" R

a division of PABCO® building products, LLC

Description:

Primary Uses:

PABCO® WATER CURB® is manufactured using 100% recycled paper distinguishable by a blue-green face paper treated to resist moisture, a chemically treated water resistant and fire resistant gypsum core, and a blue-green or grey back paper also treated to resist moisture. The face paper is folded around the long edges to reinforce and protect the core; the ends are square cut and finished smooth. Long edges of panels are tapered providing a recessed area which allows joints to be reinforced and concealed with joint treatment, creating a monolithic wall finish.

PABCO® WATER CURB® panels are available in the following thicknesses:

• 1/2" thickness panels manufactured with a non-combustible water resistant core, for use in non-rated assemblies, and• 5/8" thickness panels manufactured with a type X, water resistant core, for use in fire and sound rated systems, and in most commercial applications.

PABCO® Gypsum endorses and recommends the application specifications published in GA-216 (Application and Finishing of Gypsum Panel Products available from www.gypsum.org), as well as ASTM C840.

PABCO® WATER CURB® panel joints shall be taped with one coat of taping compound; no finish coats are to be applied to areas intended to receive tile. Applications whereby tile or plastic wall panels are applied over PABCO® WATER CURB® panels, the attachment shall be that specified by the surface manufacturer. Responsibility for performance of the finished system shall be that of the surfacing material manufacturer and/or that of the finishing applicator.

PABCO® WATER CURB® panels:• Are for interior applications only, and shall not be used where there will be direct exposure

to moisture or high humidity such as: tub surrounds, showers, saunas, indoor pools, or steam rooms.

• Are not recommended over construction materials other than wood or steel studs.• Shall not be installed over a vapor retarder. Asphalt impregnated felt, #15 or less, shall not be

considered a vapor retarder.• Shall not be exposed to sustained temperatures exceeding 125o F (52o C).• Are non-structural, not to be used as a structural fastener base, or to support heavy wall or

ceiling mounted objects. • When utilized on wall applications, a gap of 1/4" between the bottom edges or ends

of panels and the floor must be maintained, or any other horizontal surface where water may accumulate.

• Where the application of tile is to be applied as the finish material, the use of resilient channel is not recommended.

Limitations& Application:

PABCO® Gypsuma division of PABCO® building products, LLCPO Box 419074Rancho Cordova, CA 95741Technical Services: 866-282-9298www.pabcogypsum.com

PABCO® WATER CURB® is a specially-formulated gypsum wallboard product intended as a base for ceramic or plastic wall tile or plastic finish panels in dry areas. PABCO® WATER CURB® may also be painted or otherwise decorated.

PABCO® WATER CURB® may be used on ceiling areas where extra framing is provided: 12" on-center maximum spacing for 1/2" thick gypsum panels, and 16" on-center maximum spacing for 5/8" thickness.

Submittal 09 29 00

WATER CURB®R EGULAR & TYPE X Gypsum Backing Board

PABCO® Gypsum Specification PGS-003ASTM specification C 1396Available in MOLD CURB® Plus

Page #32

tothe ®

Page 37: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

WATER

CURB®

TYPE X

WAT

ER C

URB

®TY

PE X

WATER

CURB®

TYPE X

WAT

ER C

URB

®TY

PE X

WATER

CURB®

TYPE X

WAT

ER C

URB

®TY

PE X

WATER

CURB®

TYPE X

WAT

ER C

URB

®TY

PE X

SJ -ver 06-06-11/Water Curb®; PABCO® Gypsum

Storage & Handling: Store all PABCO® gypsum panels flat; do not store on edge as panels are heavy and may fall over causing injury or death. Store in an area that offers protection from adverse weather conditions, condensation, and other forms of moisture. Avoid job site conditions that expose gypsum board to water or moisture. Plastic shipping bags are temporary, and intended for protection during transit only, and must be removed promptly upon arrival. Store gypsum board under protected cover, off the ground with sufficient support to prevent sagging. Exercise proper care to avoid impact, scuffing of the paper faces, undue flexing, and damage to board edges, corners, and ends.

Submittal Approvals: Job name:Contractor: Date:

Product UL Core Type Thickness Width Length1 Weight2

WATER CURB® Regular N/A 1/2" 48" 8', 12' 1.8 lbs/ft2

WATER CURB® type X PG-5W 5/8" 48" 8', 12' 2.4 lbs/ft2

Packaging: 2 pieces per bundle, face-to-face, and end taped.Edge type: Tapered1 Other lengths may be available on a special order basis. Consult with your local PABCO® representative, or call

PABCO® Technical Assistance.2 Represents approximate weight for design and shipping purposes. A more exact weight may be available for your

area; consult with your local PABCO® representative, or call PABCO® Technical Assistance.

Product Data,Sizes and Types:

Fire Resistance Rated assembly designs are promulgated from tests performed at IAS* certified independent testing laboratories, and these designs include specific materials assembled in a precise configuration. When choosing construction details to achieve specific fire resistance rated requirements, care must be taken to insure that each component of the specified assembly is the proper one specified in the test report, and assembled in accordance with the specific requirements of the assembly. *(The International Accreditation Service —IAS— is a non-profit, public benefit corporation and a leading accreditation body in the United States. Internationally recognized, accreditation by IAS makes it easier to market products and services both inside and outside the United States.)

Fire Resistant Ratings:

Applicable Standards & Technical Data:

Manufacturing: ASTM C 1396 Federal Specification SS-L-30D Type VII *Installation: Gypsum Association GA-216, GA-214; www.gypsum.org ASTM C 840, www.astm.orgFire-Resistant Assemblies: Gypsum Association GA-600, Fire Design Manual Underwriters Laboratories, UL Fire Resistance Directory Surface Burning ASTM E 84; UL: Fire Resistance DirectoryCharacteristics: Flame Spread 15, Smoke Developed 0Non-Combustible: ASTM E 136, www.astm.org

“R” value: 1/2" = 0.45; 5/8" = 0.48 Thermal ResistanceVOC/Asbestos: Free of VOC (Volatile Organic Compound) & asbestosMaterial Safety Data Sheet: MSDS available at www.pabcogypsum.com, Technical DataPABCO Gypsum: “Construction Guide - Fire & Sound Rated Systems”Recycled Content: Refer to PABCO® Sustainable Materials Data Sheet for plant specific details.Please check our website at www.pabcogypsum.com for the latest edition of this specification.

* The federal specification for gypsum board, SS-L-30d was withdrawn in 1984. It is provided here for informational purposes only.

Limited Warranty: PABCO® Building Products, LLC, warrants that on the date the gypsum board is shipped from its manufacturing plant the gypsum board is free from defects in materials and manufacture. NOTWITHSTANDING THE FOREGOING, IT IS THE RESPONSIBILITY OF THE GYPSUM BOARD APPLICATOR TO NOTIFY PABCO BUILDING PRODUCTS, LLC, IN WRITING WITHIN TWENTY FOUR (24) HOURS OF DISCOVERY OF ANY VISIBLY DEFECTIVE GYPSUM BOARD PRIOR TO SUCH VISIBLY DEFECTIVE GYPSUM BOARD BEING APPLIED; FAILURE TO DO SO MAY FURTHER LIMIT OR VOID THE RESPONSIBILITIES OF PABCO BUILDING PRODUCTS, LLC, UNDER THIS WARRANTY. This warranty will remain in place for one year from the date of shipment from the manufacturing plant. THIS EXPRESS WARRANTY IS THE EXCLUSIVE WARRANTY PROVIDED BY PABCO® BUILDING PRODUCTS, LLC, AND SUPERSEDES ANY PRIOR, CONTRARY OR ADDITIONAL REPRESENTATIONS, WHETHER ORAL OR WRITTEN. PABCO® BUILDING PRODUCTS, LLC, HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES – WHETHER EXPRESS, IMPLIED, OR STATUTORY – INCLUDING ANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

If the gypsum board fails to conform to the foregoing warranty in Paragraph 1 and such nonconformity is not due to misuse or improper maintenance or storage, Buyer shall notify PABCO® Building Products, LLC, in writing, and within 60 days of discovery, PABCO® Building Products, LLC, shall provide, at its sole and absolute discretion, one of the following: (i) repair or replacement of any nonconforming or defective gypsum wallboard; or (ii) credit or full refund of the purchase price. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER FOR ANY BREACH OF WARRANTY.

IN NO EVENT SHALL PABCO® BUILDING PRODUCTS, LLC, BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, or strict liability in tort or under any other legal theory.

Trademarks: The following trademarks used herein are owned by Pacific Coast Building Products and licensed to PABCO® Gypsum: PABCO®, PABCORE®, FLAME CURB®, WATER CURB®, MOLD CURB®, Quality to the Core®, and ABUSE CURB™. Note: Products described herein may not be available in all geographic markets. Consult your PABCO® Gypsum sales representative for information.

Page #33

Page 38: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

Gypsum—hydrous calcium sulfate—is an abundant, naturally occurring mineral quarried for a variety of uses, the most common, of course, being gypsum board. Roughly 90

percent of finished interior surfaces are covered today with gypsum products.

Two molecules of water are chemically bound to each calcium sulfate group during the formation of the gypsum crystal. As a result, gypsum is about 21 percent chemically combined water. One of the many unique properties of gypsum is its ability to give up these water molecules as steam when heated, in a process known as calcination, making gypsum board ideally fire-resistant.

The most important characteristic of drywall, say fire officials, is that it will not burn. “Statistics show that in recent years, fewer people have died in fires in the U.S.,” says the Gypsum Association. “Naturally, there is no single reason for the decline. But the diminished number has a high correlation with the increased use of gypsum products and other fire-resistant building materials,” they say.

“The gypsum in the core of the board actually emits steam when exposed to fire and retards transfer through the panel. This slowdown provides extra time to evacuate a room or building.” It can, in a sense, be compared to what happens when a blowtorch is turned on a block of ice. Although the ice is being melted, one can hold a hand on the opposite side without being burned. Even though

the ice gets very thin it effectively blocks the transfer of the intense heat and one’s hand would not be burned until the ice is melted.

When gypsum-protected wood or steel structural members are exposed to a

fire, the chemically combined water (being released as steam) acts as a thermal barrier until this slow process, known as calcination, is completed. The temperature directly behind the plane of calcination is only slightly higher than that of boiling water (212°F), which is significantly lower than the temperature at which steel begins losing strength or wood ignites. Once calcination is complete, the in-place calcined gypsum continues to act as a barrier protecting the underlying structural members from direct exposure to flames.

Fire Resistive Properties of Gypsum

Fire Safety in Building Design

Fire safety today is one of the most critical issues in designing and constructing any modern structure. Of course, the basic goal and objective is to reduce the probability that

a person in or adjacent to a building will be exposed to an unacceptable fire hazard as a result of the design and construction of the building. Although the potential for being killed or injured in a fire cannot be completely eliminated, fire safety in a building can be achieved through proven building design features intended to minimise the risk of harm to people from fire to the greatest extent possible.

Designing a structure to ensure minimal risk or to meet a prescribed level of safety from fire is more complex than just the simple consideration of what building materials will be used.

Our ability to design ever-more fire resistant structures emphasizes the vital importance architects and engineers face in selecting the proper building materials and fire-resistant assemblies to protect against loss of life, and limit fire impact on the community.

Calcium Sulfate Dihydrate

Page #34

Page 39: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

Section III:Fire & Sound Rated Systems

Page 40: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

"Quality to the Core" R

a division of PABCO® building products, LLC

FIRE & SOUND RATED SYSTEMS

PABCO® Gypsum is proud to list hundreds of UL fire tested assemblies shown on the opposite page. All of these assemblies are UL approved, and allow the use of one or more PABCO® products available from our extensive range of gypsum board product line. Each assembly is tested within a controlled laboratory setting, and receives individual engineering evaluations. The following design selection pages present a relative small fraction of the available approved assemblies. Individual designs are prefaced with a brief description and summary. The complete design, and updated information, may be found in the Underwriter Laboratories (UL) Fire Resistant Directory (www.ul.com), the Gypsum Association’s “Fire Resistance Design Manual” (GA-600) (www.gyspum.org), or by contacting PABCO® Gypsum Technical Services.

PABCO® Gypsum type X products bear the UL Classification Mark and are covered by UL’s classification and Follow-Up Service.

The facing page is a cross reference of appropriate PABCO® Gypsum panel products to use for different UL fire-resistive Designs.

Although the systems are arranged herein (as well as the GA-600) in general groupings (i.e. walls and interior partitions, floor-ceilings, roof-ceilings, etc.), the listing of a system in a specific category is not intended to limit its use to that category. However, this shall not be interpreted to imply that vertical systems, such as walls and partitions, are permitted to arbitrarily be used in a horizontal orientation.1

1. Gypsum Association GA-600-2009, pg 7

Agency Fire Agency Sound Sound RatingsASTM American Society for Testing and

MaterialsBBN Bolt, Beranek and Newman CAC Ceiling attenuation class per

ASTM proceduresG & H Geiger & HammeCEG Consulting Engineers Group CK Cedar Knolls Acoustical Labs IIC Impact insulation class per ASTM

proceduresGA Gypsum Association (Fire Resistance Design Manual GA-600)

KAL Kodaras Acoustical LaboratoriesRAL Riverbank Acoustical Laboratories STC Sound transmission class per

ASTM proceduresOSU Ohio State University SA Shiner & Assoc.U of C University of California USG USG CorporationUL Underwriters Laboratories Inc NGCTS National Gypsum Corp Testing ServiceWHI Warnock Hersey InternationalFM Factory MutualITS Intertek Testing Services NA IncSwRI Southwest Research InstituteWFCi Western Fire Center, Inc.

Abbreviations:

For more information:

Fire Resistance Ratings:

Notes pertaining to design listings:

Fire Resistance Assemblies:

Underwriters Laboratories (UL), ASTM, and numerous building codes use fire-resistant ratings as a measure of fire-containment for varying types of building construction assemblies. In respect to buildings, the fire resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire resistance rated walls, ceiling and floor assemblies. These fire-resistance rated assemblies are tested, certified and listed in the directories of accredited Fire Testing Laboratories. The most up-to-date information is available at the fire testing laboratory website or from PABCO® Gypsum Technical Services.

• Refer to Underwriters Laboratories (UL) Fire Resistance Directory at www.ul.com.• Refer to the Gypsum Association Fire Resistance Design Manual, publication GA-600.• Contact PABCO® Gypsum Technical Services, or your qualified PABCO® Gypsum Field

Representative (please reference the back cover of this publication for contact information).

• Spacing of stud, joist, or trusses are maximum for fire rating• Size of the studs are minimum• Metal studs and runners are nominal 25 gage unless otherwise specified• Metal studs and runners greater than specified as tested shall be permitted, however STC ratings may

be negatively effected

SJ B4--22-09/ Fire Rated Systems/ PABCO® GypsumPage #36

Page 41: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

Page #37

"Quality to the Core" R

a division of PABCO® building products, LLC

tothe ®

PABCO® Product UL Core width UL Fire Rated System Assembly listing

• 5/8" FLAME CURB® type X

• 5/8" Soffit Board type X

PG-11* 46" to

54"

5/8 in. thick, 46 to 54 in. wide, Type PG-11 for use in Design Nos.: G501, G503, G505, G507, G508, G531, L501, L508, L532, L556, L591, N501, N502, N505, P508, P510, P511, P517, P540, P541, U017, U026, U207, U208, U301, U302, U305, U309, U321, U326, U329, U330, U337, U338, U339, U341, U342, U344, U351, U354, U355, U356, U357, U358, U360, U364, U368, U369, U374, U379, U411, U418, U420, U421, U425, U434, U436, U439, U442, U445, U449, U450, U460, U465, U466, U467, U469, U473, U485, U487, U494, U502, U504, U505, U506, U510, U512, U603, U606, U609, U615, U617, U622, U625, U637, U640, V417, V419, V421, V431, X508, X510, X516, X517, X525, X526, X527, X528.

• 5/8" FLAME CURB® Super C

• 5/8" Soffit Board Super C

Type C 48" 5/8 in. thick, 4 ft wide, Type C for use in Design Nos.: D301, D501, D502, G501, G503, G505, G512, G515, G521, G523, G525, G526, G527, G528, G529, G530, G531, G538, J501, J502, J503, J504, L501, L505, L508, L511, L512, L513, L514, L516, L520, L523, L525, L526, L527, L528, L529, L530, L538, L539, L540, L541, L548, L588, L591, L592, N501, N502, N505, P501, P502, P503, P504, P505, P506, P507, P508, P509, P510, P513, P514, P519, P549, U023, U301, U302, U305, U309, U311, U329, U333, U334, U340, U342, U354, U355, U379, U411, U428, U429, U442, U445, U451, U457, U465, U466, U467, U469, U473, U485, U501, U502, U504, U505, U506, U510, U512, U602, U603, U605, U617, U618, U627, U634, U635, U639, U640, U642, U643, U644, U645, V414, V417, V419, X501, X502, X504, X508, X509, X516, X517, X525, X526, X527, X528.

• 1/2" FLAME CURB® Super C PG-C 48"1/2 in. thick, 4 ft wide, Type PG-C for use in Design Nos.: G502, G504, G515, G523, G524, G526, G527, G528, G529, G530, G531, G533, G534, L502, L503, L504, L507, L510, L512, L514, L524, L525, L530, L542, P237, P510, P512, U312, U317, U320, U406, U410, U412, U426, U428, U429, U435, U436, U438, U440, U441, U443, U444, U448, U451, U452, U453, U454, U455, U467, U474, U478, U601, U603, U608, U611, U613, U614, U619, U620, U910, U912, U914, V418, X507, X513, X514, X515, X518, X520, X521, X522, X523, X524, X530, X531.

• 1/2" FLAME CURB® type XXX

• 1/2" Soffit type XXXPG-3

48" 1/2 in. thick, 4 ft wide, Type PG-3 for use in Design Nos.: G502, G504, G523, G524, G526, G528, L502, L503, L504, L507, L580, P237, U312, U317, U410, U502, U603, U608, U611, U613, U614, U619, U620, X513, X520.

46" to

54"

1/2 in. thick, 46 to 54 in. wide, Type PG-3 for use in Design Nos.: G504, L503, L504, U317, U502, U611, U613, U614.

• 5/8" WATER CURB® type X

• 5/8" MOLD CURB® Plus type X

• 5/8" Gypsum Sheathing type X

• 5/8" MOLD CURB® Plus Sheathing type X

• ABUSE CURB™

PG-5WPG-5WS

48" 5/8 in. thick, 4 ft wide, Type PG-3W , PG-3WS , PG-5W or PG-5WS for use in Design Nos.: U301, U305, U342, U354, U355, U379.

46" to

54"

5/8 in. thick, 46 to 54 in. wide, Type PG-5W or PG-5WS for use in Design Nos.: U301, U305, U354, U379.

• 1" PABCORE® SHAFTLINER, • 1" PABCORE® MOLD CURB® Plus

SHAFTLINER

PG-10 24" 1 in. thick, 24 in. wide Type PG-10 for use in Design Nos. U428, U429.

Updates and current information: Information referred to in this document may change without notice. Visit www.ul.com for current information, or call PABCO® Technical Services @ 866-282-9298

UL FIRE RATED SYSTEM ASSEMBLY CROSS REFERENCE

by PRODUCT

SJ- 4-18-11 PABCO® Gypsum

* (PG-11 replaces PG-9)

PABCO® products currently manufactured below are appropriate to use in the following UL Fire Rated Assemblies, as shown in UL CKNX.R7094. March 2009

Page 42: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

GUIDE to ASSEMBLIES - Fire & Sound

Fire Rating

STC GA File Number Page

WALLS & INTERIOR PARTITIONSSteel Framed

1 hr 55-59 WP 1015 40

1 hr 50-54 WP 1021 40

1 hr 45-49 WP 1070 40

1 hr 40-44 WP 1206; (UL U425) 40

1 hr 35-39 WP 1350; 40

2 hr 55-59 WP 1521 41

2 hr 55-59 WP 1522 41

2 hr 50-54 WP 1545 41

2 hr 50-54 WP 1548 41

2 hr 45-49 WP 1616; (UL411) 42

2 hr 45-49 WP 1635; (UL U425) 42

2 hr 40-44 WP 1716; (UL U425) 42

2 hr 50* (UL U421) *STC Estimated 42

3 hr 50-54 WP 2022; (UL U435) 43

4 hr 55-59 WP 2961; (UL U435) 43

WALLS & INTERIOR PARTITIONS, CHASE WALLSWood Framed

45 m (UL U317) 44

1 hr 50-54 WP 3241; (UL U311) 44

1 hr 50-54 WP 3242; (UL U309) 44

1 hr 50-54 WP 3243; (UL U309) 44

1 hr 45-49 WP 3370; (UL U305) 45

1 hr 45-49 WP 5512; (UL U305) 45

1 hr 40-44 WP 3880; (UL U305) 45

1 hr 40-44 WP 5515; (UL U305) 45

1 hr 35-39 WP 3510; (UL U309; UL U314) 46

1 hr 35-39 WP 3514 46

1 hr 35-39 WP 3520 46

1 hr 30-34 WP 3605 46

2 hr 55-59 WP 3812 46

2 hr 55-59 WP 3810 47

2 hr 55-59 WP 3820; WP 5520 47

2 hr 50-54 WP 3910, WP 5530; (UL R4024) 47

2 hr 40-44 WP 4135, WP 4136 47

GUIDE OVERVIEW:

This GUIDE to ASSEMBLIES presents a small selection of assemblies in which PABCO® Gypsum products have been approved for use. There are numerous other approved assemblies available within each of the following sections.

Listed within each section (for example: Walls & Interior Partitions, Steel Framed), assemblies are arranged sequentially in increasing fire ratings. Within each grouping of fire ratings (for example, one hour), the assemblies’ Sound Ratings (STC) are listed in decreasing order of STC.

Each assembly listing provides a reference to the Gypsum Association File Number and/or UL Design Number for additional information, as well as the page number directing you to the test description listed on the following pages of this guide.

As this is a “selection” of assemblies for which PABCO® products have been approved for use, it is important to note that there are numerous other approved assembles. These additional assemblies are described in detail in the Gypsum Association Fire Resistant Design Manual GA-600 (current is the 19th edition), as well as within UL’s Certification Directory CKNX.R7094 (see UL® Fire Rated Systems Product Selection Guide, previous page).

DRAFT

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

SJ 6-14-11/Guide to Fire Rated Systems/ PABCO® GypsumPage #38

Page 43: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

GUIDE to ASSEMBLIES - Fire & Sound

Fire Rating

STC GA File Number Page

SHAFT WALL SYSTEMS1 hr 45-49 WP 6800 48

2 hr 50-54 WP 7051; (UL U428) 48

2 hr 50-54 WP 7052; (UL U429) 48

2 hr 45-49 WP 7082 49

2 hr 45-49 WP 7083 49

AREA SEPARATION WALL SYSTEMS2 hr 60-64 ASW 0985 50

2 hr 50-54 ASW 1100 50

2 hr 50-54 ASW 1105 50

FLOOR CEILING - Steel Framed1 hr 50-54 FC 4340 51

1 hr FC 4529, (UL L524) 51

1.5 hr (UL L527) 51

2 hr FC 4750; (UL L556) 51

2 hr 50-54 FC 2030; (UL G514) 52

2 hr 50-54 FC 3012; (UL G512) 52

FLOOR CEILING - Wood Framed1 hr 55-59 FC 5105; (UL L502) 53

1 hr 55-59 FC 5107; (UL L514) 53

1 hr 50-54 FC 5111 53

1 hr 50-54 FC 5116; (UL L516) 53

1 hr 50-54 FC 5120 54

1 hr 45-49 FC 5241 54

1 hr 45-49 FC 5250; (UL L502) 54

1 hr 35-39 FC 5415; (UL L513) 54

1 hr 35-39 FC 5406 55

1 hr 35-39 FC 5407 55

1 hr 35-39 FC 5410; (UL L512, L522, L503, L519) 55

1 hr 35-39 FC 5420; (UL L501) 55

1 hr FC 5520; (UL L592) 56

1 hr FC 5515; (UL L528) 56

2 hr FC 5751; (UL L556) 56

2 hr FC 5710; (UL L511) 57

2 hr FC 5724; (UL L505) 57

2 hr FC 5750; (UL L556) 57

Fire Rating

STC GA File Number Page

ROOF CEILING - Wood Framed1 hr RC 2608; (UL P549) 58

1 hr RC 2602 58

2 hr RC 2750; (UL L556) 58

2 hr RC 2751; (UL L556) 59

COLUMNSLight Tubular Columns:

1 hr CM 1452; (UL X528) 60

1 hr CM 1851, (UL X528) 60

1.5 hr CM 2455; (UL X531) 60

2 hr CM 2455; (UL X528) 60

Column 10WF-49

1 hr CM 1001; (UL X528) 60

2 hr CM 2017; (UL X528) 61

3 hr CM 3120; (UL X509, X510) 61

4 hr (UL X501) 61

Column 14WF-228

2 hr CM 2110; (UL X520) 61

3 hr CM 3130; (UL X513) 61

BEAMS & GIRDERS1 hr BM 1137; (UL L524) 62

2 hr BM 2120; (UL N501) 62

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

SJ 6-14-11/Guide to Fire Rated Systems/ PABCO® GypsumPage #39

Page 44: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

1hr

NA

WP 1015

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer PABCO® 1/4" Regular gypsum wallboard applied parallel to each side of 2-1/2" steel studs 24" o.c.

Face layer 5/8" FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8" PABCO® type X gypsum sheathing applied parallel to each side.

Joints staggered 24" each layer and side. Sound tested with 1-1/2" mineral fiber insulation, 3.0 pcf, friction fit in stud space.

NON-LOAD BEARING

Fire Test: See WP 1051(FM WP 152-1)

55-59

Sound Test: CK 684-14

1 hr

NA

WP 1021

PABCO® GYPSUM WALLBOARD, STEEL STUDS

One layer 1/2" FLAME CURB® type XXX gypsum wallboard applied parallel to ONE SIDE of 2-1/2" steel studs 24" o.c.

OPPOSITE SIDE: Base layer 1/2" FLAME CURB® type XXX gypsum wallboard applied parallel to studs.

Face layer 1/2" FLAME CURB® type XXX gypsum wallboard applied parallel to studs.

Joints staggered 24" each layer and side. Sound tested with 3-1/2" glass fiber insulation friction fit in stud space and all layers screw attached without adhesive.

NON-LOAD BEARING

Fire Test:FM WP 66

50-54

Sound Test:RAL TL88-55

1 hr 45-49 WP 1070

PABCO® GYPSUM WALLBOARD, STEEL STUDS, MINERAL FIBER INSULATION

One layer 1/2" FLAME CURB® type XXX gypsum wallboard applied parallel to each side of 2-1/2" steel studs 24" o.c. 2" mineral fiber insulation, 2.5 pcf, friction fit in stud space. Also fire tested with 1-1/2" mineral fiber insulation, 3.0 pcf, stapled to board in stud space. Joints staggered 24" on opposite sides

NON-LOAD BEARING

Fire Test:FM WP 51-1,OSU T-3362,

Sound Test:RAL TL69-42

1 hr 40-44 WP 1206

PABCO® GYPSUM WALLBOARD, STEEL STUDS

One layer 5/8" FLAME CURB® type X gypsum wallboard, 5/8" WATER CURB® type X backing board, or 5/8" PABCO® type X gypsum sheathing applied parallel to each side of 3-1/2" 20 gage steel studs 24" o.c.

Joints staggered 24" on opposite sides.

Bracing requirement. LOAD BEARING

Fire Test: UL NC 505-2, UL DESIGN U425

Sound test: see WP 1350 NGC 2385

1 hr 35-39 WP 1350

PABCO® GYPSUM WALLBOARD, STEEL STUDS

One layer 5/8" FLAME CURB® type X gypsum wall board, 5/8" WATER CURB®, or 5/8" PABCO® type X gypsum sheathing applied parallel or at right angles to each side of 3-5/8" steel studs 24" o.c.

Joints staggered 24" on opposite sides.

NON-LOAD BEARING

Fire Test:FM WP-45;OSU T-1770;ULC 79T484, 79T500, 79T497, ULC Design W415

Sound Test:NGC 2005004RAL TL06-114

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

4-1/4˝

4-1/4˝

4-3/4˝

3-1/2˝

4-7/8˝

SJ- 6-07-11/ Fire Rated Systems- PABCO® GypsumPage #40

"Quality to the Core" R

a division of PABCO® building products, LLC

FIRE RATED SYSTEMSWALLS & INTERIOR PARTITIONS Steel Framed

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 45: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

2 hr

NA

WP 1521

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 1/2" FLAME CURB® type XXX gypsum wallboard applied parallel to each side of 3-5/8" steel studs 24" o.c.

Face layer 1/2" FLAME CURB® type XXX gypsum wallboard applied parallel to each side.

Joints staggered 24" each layer and side. Sound tested with 3-1/2" glass fiber friction fit in stud space.

NON-LOAD BEARING

Fire Test: See WP 1545(UC;ULC 80T499ULC Design W414)

55-59

Sound Test: NRCC 815-NV

2 hr

NA

WP 1522

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 5/8" FLAME CURB® type X gypsum wallboard, 5/8" WATER CURB® type X backing board, or 5/8" PABCO® type X gypsum sheathing applied parallel or at right angles to each side of 3-5/8" steel studs 24” o.c.

Face layer 5/8" FLAME CURB® type X gypsum wallboard, 5/8" WATER CURB® type X backing board, or 5/8" PABCO® type X gypsum sheathing applied parallel or at right angles to each side.

Joints staggered 24" each layer and side. Sound tested with 3-1/2" glass fiber friction fit in stud space.

NON-LOAD BEARING

Fire Test: See WP 1548(WHI-495-0236

55-59

Sound Test: NRCC 818-NV

2 hr

NA

WP 1545

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 1/2" FLAME CURB® type XXX gypsum wallboard applied parallel to each side of 2-1/2" steel studs 24" o.c.

Face layer 1/2" FLAME CURB® type XXX gypsum wallboard applied parallel to each side of 1-5/8" steel studs 24" o.c.

Joints staggered 24" each layer and side. Sound tested with 1-1/2" mineral fiber insulation friction fit in stud space.

NON-LOAD BEARING

Fire Test:UC, ULC 80T499,ULC Design W414

50-54

Sound Test: CK 654-40

2 hr

NA

WP 1548

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base Layer 5/8" FLAME CURB® type X gypsum wallboard, 5/8" WATER CURB® type X backing board, or 5/8" PABCO® type X gypsum sheathing applied parallel or at right angles to each side of 2-1/2" steel studs 24" o.c.

Face layer: 5/8" FLAME CURB® type X gypsum wallboard, 5/8" WATER CURB® type X backing board, or 5/8" PABCO® type X gypsum sheathing applied parallel or at right angles to each side.

Joints staggered 24" each layer and side.

Sound tested with 2-1/2" glass fiber insulation friction fit in stud space.

NON-LOAD BEARING

Fire Test: WHI-495-0236

50-54

Sound Test: WHI-218-1

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

5-5/8˝

6-1/8˝

6-1/8˝

5-5/8˝

4-1/2˝

4-1/2˝

SJ- 6-07-11/ Fire Rated Systems- PABCO® GypsumPage #41

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

FIRE RATED SYSTEMS WALLS & INTERIOR PARTITIONS Steel Framed (continued)

Page 46: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

2 hr 45-49 WP 1616

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 5/8" FLAME CURB® type X gypsum wallboard, 5/8" WATER CURB® type X backing board, or 5/8" PABCO® type X gypsum sheathing applied parallel to each side of 3-5/8" steel studs 24" o.c.

Face layer 5/8" FLAME CURB® type X gypsum wallboard, 5/8" WATER CURB® type X backing board, or 5/8" PABCO® type X gypsum sheathing applied parallel to each side, laminating compound combed over entire surface. Metal base and top retainer channels.

Joints staggered 24" each layer and side. NON-LOAD BEARING

Fire Test: UL R1319-31UL Design U411

Sound Test: NGC 2005005,RAL TL06-115,

2 hr 45-49 WP 1635

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 1/2" FLAME CURB® type XXX gypsum wallboard applied parallel to each side of 3-1/2" 20 gage steel studs 24" o.c.

Second layer 1/2" FLAME CURB® type XXX gypsum wallboard applied parallel to each side.

Face layer 1/2" FLAME CURB® type XXX gypsum wallboard applied parallel or at right angles to each side.

Studs attached to each side of floor and ceiling runners.

Joints staggered 24" each layer and side. Bracing requirement. LOAD BEARING

Fire Test: UL NC 505-4UL Design U425

Sound Test: Estimated

2 hr 40-44 WP 1716

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 5/8" FLAME CURB® type X gypsum wallboard, 5/8" WATER CURB® type X backing board, or 5/8" PABCO® type X gypsum sheathing applied parallel to each side of 3-1/2” 20 gage steel studs 24" o.c.

Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied parallel to each side.

Joints staggered 24" each layer and side. Bracing requirement LIMITED LOAD BEARING

Fire Test: UL NC 505-6,UL Design U425

Sound Test: See WP 1615(NGC 2250)

2 hr NA

GYPSUM WALLBOARD, STEEL STUDS

Base layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied vertically or horizontally on both sides of the studs, with vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Horizontal edge joints (when applied horizontally) and horizontal butt joints (when applied vertically) on opposite sides of studs need not be staggered or backed.

Remaining two layers 5/8” FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied vertically or horizontally on one side of the wall. Horizontal butt joints staggered a min of 6 in. on adjacent layers.

When used in widths other than 48 in., gypsum panels to be installed horizontally. NON-LOAD BEARING

Fire Test: UL Design U421

Sound Test: *Estimated

50*

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

6-1/8˝

6-1/2˝

SJ- 6-07-11/ Fire Rated Systems- PABCO® GypsumPage #42

FIRE RATED SYSTEMS WALLS & INTERIOR PARTITIONS Steel Framed (continued)

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 47: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

3 hr

NA

WP 2922

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 1/2" FLAME CURB® Super C gypsum wallboard applied parallel to each side of 1-5/8" steel studs 24" o.c.

Second layer: 1/2" FLAME CURB® Super C gypsum wallboard applied at parallel or at right angles to each side.

Face layer 1/2" FLAME CURB® Super C gypsum wallboard applied at right angles to each side.

Joints staggered 24" each layer and side.

Sound tested with 1-1/2" glass fiber insulation friction fit in stud space.

NON-LOAD BEARING

Fire Test: WHI-495-0804,UL R7094, UL Design U435

50-54

Sound Test: WEAL 87-118,

4 hr

NA

WP 2961

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 1/2" FLAME CURB® type XXX gypsum wallboard applied parallel to each side of 1-5/8" steel studs 24" o.c.

Second layer: 1/2" FLAME CURB® type XXX gypsum wallboard applied parallel to each side.

Third layer 1/2" FLAME CURB® type XXX gypsum wallboard applied parallel or at right angles to each side.

Face layer 1/2" FLAME CURB® type XXX gypsum wallboard applied at right angles to each side.

Joints staggered 24" each layer and side.

Sound tested with 1-1/2" glass fiber insulation friction fit in stud space.

NON-LOAD BEARING

Fire Test: WHI 495-0819;UL R7094,UL Design U435

55-59

Sound Test: WEAL 87-119

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

4-5/8˝

4-5/8˝

5-5/8˝

5-5/8˝

SJ- 6-07-11/ Fire Rated Systems- PABCO® GypsumPage #43

FIRE RATED SYSTEMS

FIRE RATED SYSTEMS WALLS & INTERIOR PARTITIONS Steel Framed (continued)

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

tothe ®

Page 48: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

45 min

NA NA

1/2” PABCO® FLAME CURB® type XXX, or 1/2” PABCO® FLAME CURB® Super C.

LOAD BEARING - Nail Attached

Fire Test:UL U317

1 hr 50-54 WP 3241

PABCO® GYPSUM WALLBOARD, RESILIENT CHANNELS, MINERAL FIBER INSULATION, WOOD STUDS

Resilient channels 24” o.c. attached at right angles to ONE SIDE of 2 x 4 wood studs 16” or 24” o.c. One layer of 5/8” FLAME CURB® Super C gypsum wallboard applied parallel to channels. End joints backblocked with resilient channels. 3” mineral fiber insulation, 2.0 or 2.3 pcf, in stud space.

OPPOSITE SIDE: One layer of 5/8” FLAME CURB® Super C gypsum wallboard applied at right angles to studs.

Vertical joints staggered 48” on opposite sides. Sound tested with studs 16” o.c. and open face of mineral fiber insulation blankets toward resilient channel-side of stud space.

LOAD BEARING - Screw attachment

Fire Test: Based on UL R3660-7, UL R2717-61, UL Design U311

Sound Test:Estimated

1 hr 50-54 WP 3242

PABCO® GYPSUM WALLBOARD, RESILIENT CHANNELS, MINERAL OR GLASS FIBER INSULATION, WOOD STUDS

Resilient channels 16” o.c. attached at right angles to ONE SIDE of 2 x 4 wood studs 24” o.c. One layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to channels with vertical joints located midway between studs. 3” mineral or glass fiber insulation in stud space.

OPPOSITE SIDE: One layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied parallel or at right angles to studs. Vertical joints staggered 24” on opposite sides.

LOAD-BEARING - Nail attachment

Fire Test: Based on UL R14196,05NK05371, UL Design U309

Sound Test: NRCC TL-93-098, IRC-IR-761,

1 hr 50-54 WP 3243

PABCO® GYPSUM WALLBOARD, RESILIENT CHANNELS, MINERAL OR GLASS FIBER INSULATION, WOOD STUDS

Resilient channels 24” o.c. attached at right angles to ONE SIDE of 2 x 4 wood studs 24” o.c. One layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to channels with vertical joints located midway between studs. 3” mineral or glass fiber insulation in stud space.

OPPOSITE SIDE: One layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied parallel or at right angles to studs. Vertical joints staggered 24” on opposite sides.

LOAD-BEARING - Nail attachment

Fire Test: Based on UL R14196,05NK05371, UL Design U309

Sound Test: NRCC TL-93-103, IRC-IR-761,

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

5-3/8˝

5-3/8˝

5-3/8˝

4-1/2˝

SJ- 6-07-11/ Fire Rated Systems- PABCO® GypsumPage #44

"Quality to the Core" R

a division of PABCO® building products, LLC

FIRE RATED SYSTEMSWALLS & INTERIOR PARTITIONS, CHASE WALLS - Wood Framed

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 49: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

1 hr 45-49 WP 3370

PABCO® GYPSUM WALLBOARD, WOOD STUDS

One layer 5/8” FLAME CURB® type X gypsum wall board, 5/8” WATER CURB®, or 5/8” PABCO® type X gypsum sheathing applied parallel or at right angles to each side of double row of 2 x 4 wood studs 16” o.c. on separate plates 1” apart.

Joints staggered 16” on opposite sides. Horizontal bracing required at mid-height.

LOAD BEARING - Nail Attachment

Fire Test: See WP 3605(UL R1319-4, 6,UL R2717-39, UL R3501-52,UL Design U305;ULC Design W301); UL R 4024

Sound Test: NRCC TL-93-261 IRC-IR-761

1 hr 45-49 WP 5512

PABCO® GYPSUM WALLBOARD, WOOD STUDS

One layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied parallel or at right angles to each side of double row of 2 x 4 wood studs 16” o.c. on separate plates 1” apart.

Joints staggered 16” on opposite sides. Horizontal bracing required at mid-height.

LOAD BEARING - Nail attachment

Fire Test:See WP 3605 (UL R1319-4, -6,UL R2717-39, UL R3501-52,UL Design U305; ULC Design W301);UL R4024

Sound: NRCC TL-93-261 IRC-IR-761

1 hr 40-44 WP 3380

PABCO® GYPSUM WALLBOARD, WOOD STUDS

One layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied parallel or at right angles to each side of 2 x 4 wood studs 16” o.c. staggered 8” o.c. on 2 x 6 wood plates.

Joints staggered 24” on opposite sides. Horizontal bracing required at mid-height.

LOAD BEARING - Nail attachment

Fire Test: See WP 3605(UL R1319-4,-6, UL R2717-39,UL R3501-52,UL Design U305;ULC Design W301);UL R4024

Sound Test: NRCC TL-93-254, IRC-IR-761

1 hr 40-44 WP 5515

PABCO® GYPSUM WALLBOARD, WOOD STUDS

One layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied parallel or at right angles to each side of 2 x 4 wood studs 16” o.c. staggered 8” o.c. on 2 x 6 wood plates.

Joints staggered 24” on opposite sides. Horizontal bracing required at mid-height.

LOAD BEARING - Nail attachment

Fire Test: See WP 3605(UL R1319-4,-6, UL R2717-39,UL R3501-52,UL Design U305;ULC Design W301); UL R4024

Sound Test: NRCC TL-93-254 IRC-IR-761

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

FIRE RATED SYSTEMS WALLS & INTERIOR PARTITIONS, CHASE WALLS Wood Framed (continued)

7-3/4˝

7-3/4˝

9-1/4˝

9-1/2˝

SJ- 6-07-11/ Fire Rated Systems- PABCO® GypsumPage #45

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 50: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

1 hr 35-39 WP 3510

PABCO® GYPSUM WALLBOARD, WOOD STUDS

One layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied parallel or at right angles to each side of 2 x 4 wood studs 24” o.c. Joints staggered 24” on opposite sides.

LOAD-BEARING - Nail Attachment.

Fire Test: UL R3501-47, -48, UL Design U309;UL R1319-129;UL Design U314

Sound Test: NGC 2404

1 hr 35-39 WP 3514

PABCO® GYPSUM WALLBOARD, WOOD STUDS

One layer of 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied parallel or at right angles to each side of 2 x 4 wood studs 16” o.c. Joints staggered 16” on opposite sides.

LOAD BEARING - Screw Attachment

Fire Test: SWRI 01-4511-619[1]

Sound Test:See WP 3520G&H NG-246FT

1 hr 35-39 WP 3520

PABCO® GYPSUM WALLBOARD, WOOD STUDS

One layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied parallel to each side of 2 x 4 wood studs 24” o.c Joints staggered 24” on opposite sides.

LOAD-BEARING - Nail Attachment

Fire Test: FM WP 90

Sound Test: G&H NG-246FT

1 hr 30-34 WP 3605

PABCO® GYPSUM WALLBOARD, WOOD STUDS

One layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied parallel or at right angles to each side of 2 x 4 wood studs 16” o.c. Joints of square edge, bevel edge or predecorated wallboard may be left exposed. Joints staggered 16” on opposite sides.

LOAD-BEARING - Nail Attachment.

Fire Test: UL R1319-4, -6, UL R2717-39, UL R3501-52,UL Design U305;ULC Design W301

Sound Test: OR 64-8

2 hr

NA

WP 3812

PABCO® GYPSUM WALLBOARD, WOOD STUDS

Base layer 1/2” PABCO® FLAME CURB® type XXX, or 1/2” PABCO® FLAME CURB® Super C gypsum wallboard applied at right angles to 2 x 4 wood studs 24” o.c.

Face layer 1/2” PABCO® FLAME CURB® type XXX, or 1/2” PABCO® FLAME CURB® Super C gypsum wallboard applied at right angles to studs over base layer and to top and bottom plates. Joints offset 24” from base layer joints.

Inner layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied parallel. Joints in inner layer need not be taped.

Second wall duplicate of first wall and separated by 1” space. Walls independently loaded.

Sound tested with 3-1/2” glass fiber insulation, 0.75 pcf, friction fit in stud spaces. LOAD BEARING - Nail Attachment

Fire Test: See WP 3810(FM WP 297)

Sound Test: Estimated Based on WP 3810(RAL TL73-215;RAL TL73-224)

55-59

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

4-7/8˝

4-7/8˝

4-7/8˝

4-7/8˝

11-1/4˝

11-1/4˝

FIRE RATED SYSTEMS WALLS & INTERIOR PARTITIONS, CHASE WALLS Wood Framed (continued)

SJ- 6-07-11/ Fire Rated Systems- PABCO® GypsumPage #46

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 51: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

2 hr 55-59 WP 3810

PABCO® GYPSUM WALLBOARD, WOOD STUDS

Base layer 1/2” PABCO® FLAME CURB® type XXX, or 1/2” PABCO® FLAME CURB® Super C gypsum wallboard applied at right angles to 2 x 4 wood studs 24” o.c. Face layer 1/2” PABCO® FLAME CURB® type XXX, or 1/2” PABCO® FLAME CURB® Super C applied at right angles. Joints offset 24” from base layer joints. Inner layer 1/2” PABCO® FLAME CURB® type XXX, or 1/2” PABCO® FLAME CURB® Super C gypsum wallboard applied parallel to studs. Joints in inner layer need not be taped. Second wall duplicate of first wall and separated by 1” space. Walls independently loaded.STC 59 with 3-1/2” glass fiber insulation friction fit in stud spaces both sides; STC 57 without glass fiber insulation.

LOAD BEARING - Nail Attachment

Fire Test: FM WP 297

Sound Test: RAL TL73-215,RAL TL73-224

2 hr

NA

WP 3820&

WP 5520

PABCO® GYPSUM WALLBOARD, WOOD STUDS

Base layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to each side of double row of 2 x 4 wood studs 16” o.c. on separate plates 1” apart.

Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to each side.Joints staggered 16” each layer and side.

Sound tested with 3-1/2” glass fiber insulation stapled to studs in stud spaces on one side and with nails for base layer spaced 6” o.c..

Horizontal bracing required at mid-height.

LOAD-BEARING - Nail Attachment

Fire Test:See WP 4135(FM WP 360); UL R4024

55-59

Sound Test: NGC 3056

2 hr 50-54WP 3910

& WP 5530

PABCO® GYPSUM WALLBOARD, WOOD STUDS

Base layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to each side of 2 x 4 wood studs 16” o.c., staggered 8” o.c. on 2 x 6 wood plates.

Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to each side. Joints staggered 16” each layer and side.

Sound tested with nails for base layer spaced 6” o.c. Horizontal bracing required at mid-height.

LOAD BEARING - Nail Attachment

Fire Test:See WP 4135(FM WP 360);UL R4024

Sound Test:NGC 2377,

2 hr 40-44

WP 4135(Nail

attached)

PABCO® GYPSUM WALLBOARD, WOOD STUDS

Base layer 5/8” FLAME CURB® type X gypsum wall board, 5/8” WATER CURB®, or 5/8” PABCO® type X gypsum sheathing applied at right angles (parallel or at right angles for WP 4136) to each side of 2 x 4 wood studs 24” o.c. (16” o.c for WP 4136).

Face layer 5/8” FLAME CURB® type X gypsum board applied at right angles to each side. Joints staggered 24” (16” o.c. for WP 4136) each layer and side. Sound tested with studs 16” o.c. (WP 4135 only).

LOAD BEARING

Fire Test:FM WP 360,

Sound Test:NGC 2363

WP 4136 (Screw

attached)

Fire Test:SRWI 01-5920-614,Sound Test:See WP4135(NGC 2363)

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

11˝

10-3/4˝

10-3/4˝

6-1/8˝

FIRE RATED SYSTEMS WALLS & INTERIOR PARTITIONS, CHASE WALLS Wood Framed (continued)

SJ- 6-07-11/ Fire Rated Systems- PABCO® GypsumPage #47

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 52: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

1 hr

NA

WP 6800

PABCO® GYPSUM WALLBOARD, STEEL C-T STUDS

One layer 1” x 24” PABCORE® Shaftliner type X, or 1” x 24” PABCORE® MOLD CURB® Plus Shaftliner type X gypsum panels inserted between 2-1/2” floor and ceiling runners with T-Section of 2-1/2” steel C-T studs between panels.

OPPOSITE SIDE: One layer of 5/8” PABCO® FLAME CURB® Super C gypsum wallboard applied parallel to studs.

Sound tested with horizontal resilient channels 24” o.c. and 2-1/2” glass fiber friction fit in stud space.

NON LOAD BEARING

Fire Test:WHI-495-1303

45-49

Sound test:RAL TL96-28,

2 hr

NA

WP 7051

PABCO® GYPSUM WALLBOARD, STEEL C-H or C-T STUDS

One layer 1” x 24” PABCORE® Shaftliner type X, or 1” x 24” PABCORE® MOLD CURB® Plus Shaftliner type X gypsum panels inserted between 2-1/2” floor and ceiling J runners with T-Section of 2-1/2” steel C-H or C-T studs between panels.

OPPOSITE SIDE: Base layer 1/2” FLAME CURB® Super C gypsum wallboard applied at right angles to studs.

Face layer 1/2” FLAME CURB® Super C gypsum wallboard applied parallel to studs.

Sound tested with 1-7/8” glass fiber insulation in stud space.

NON LOAD BEARING

Fire Test:UL R7094,93NK8151,UL R3660, 07NK22992UL Design U428

50-54

Sound Test:RAL TL93-181

2 hr

NA

WP 7052

PABCO® GYPSUM WALLBOARD, STEEL C-H or C-T STUDS

One layer 1” x 24” PABCORE® Shaftliner type X, or 1” x 24” PABCORE® MOLD CURB® Plus Shaftliner type X gypsum panels inserted between 2-1/2” floor and ceiling J runners with T-Section of 2-1/2” steel C-H or C-T studs between panels.

Face layer 1/2” FLAME CURB® Super C gypsum wallboard applied parallel to studs with vertical joints midway between studs and laminated to 1” x 24” PABCORE® Shaftliner type X, or 1” x 24” PABCORE® MOLD CURB® Plus Shaftliner type X gypsum panels with 4” wide strips of taping compound at wallboard perimeter and vertical centerline.

OPPOSITE SIDE: One layer 1/2” FLAME CURB® Super C gypsum wallboard applied at rightangles to studs. Sound tested with 1-7/8” glass fiber in stud space.

NON LOAD BEARING

Fire Test:See WP 7051(UL R7094,93NK8151,UL Design U429)

50-54

Sound Test:See WP 7051(RAL TL93-181)

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

3-5/8˝

3-1/8˝

3-1/2˝

3-1/2˝

3-1/2˝

3-1/2˝

SJ 6-07-11/ Fire Rated Systems- PABCO® GypsumPage #48

"Quality to the Core" R

a division of PABCO® building products, LLC

FIRE RATED SYSTEMSSHAFT WALL SYSTEMS

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 53: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

2 hr

NA

WP 7082

PABCO® GYPSUM BOARD, SLOTTED STEEL I STUDS

One layer 1” x 24” PABCO® PABCORE® SHAFTLINER type X, or 1”x 24” PABCORE® MOLD CURB® Plus SHAFTLINER type X inserted between 2-1/2” floor and ceiling runners with tab-flange section of 2-1/2” slotted steel I studs between panels.

OPPOSITE SIDE: Base layer 1/2” PABCO® FLAME CURB® type XXX gypsum wallboard applied at right angles to studs.

Face layer 1/2” PABCO® FLAME CURB® type XXX gypsum wallboard applied parallel to studs.

Sound tested with 1” glass fiber insulation friction fit in stud space.

NON LOAD BEARING

Fire Test: WHI 495-0528, WHI 495-0566

45-49

Sound Test: See WP 7083(WEAL 84-108)

2 hr

NA

WP 7083

PABCO® GYPSUM WALLBOARD, SLOTTED STEEL I STUDS

One layer 1” x 24” PABCO® PABCORE® SHAFTLINER type X, or 1”x 24” PABCORE® MOLD CURB® Plus SHAFTLINER type X gypsum panels inserted between 2-1/2” floor and ceiling runners with tab-flange section of 2-1/2” slotted steel I studs between panels.

One layer 1/2” PABCO® FLAME CURB® type XXX gypsum wallboard applied parallel to each side.

Sound tested with 1” glass fiber insulation friction fit in stud space.

NON LOAD BEARING

Fire Test: WHI 495-0569, WHI 495-0570

45-49

Sound Test: WEAL 84-108

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

3-1/2˝

3-1/2˝

3-1/2˝

3-1/2˝

FIRE RATED SYSTEMS SHAFT WALL SYSTEMS (continued)

SJ 6-07-11/ Fire Rated Systems- PABCO® GypsumPage #49

tothe ®

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 54: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

2 Hr

NA

ASW 0985

PABCO® GYPSUM WALLBOARD, STEEL H STUDS

Two layers 1” x 24” PABCORE® SHAFTLINER type X, or 1”x 24” PABCORE® MOLD CURB® Plus SHAFTLINER type X inserted between 2” floor and ceiling runners with 2” steel H studs between adjacent pairs of gypsum panels.

NON LOAD BEARING

A 3/4” minimum air space must be maintained between steel components and adjacent framing (indicated by dashed lines in sketch). As an alternate, the steel components may be covered with 6” wide battens or full sheets of 1/2” PABCO® FLAME CURB® type XXX gypsum wallboard.

Sound tested with 2 x 4 stud wall faced with 1/2” PABCO® Regular wallboard each side of system and 3-1/2” glass fiber insulation in stud space.

Fire Test: WFCi #07073

60-64

Sound Test: RAL TL07-373

2 Hr

NA

ASW 1100

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 1/2” PABCO® FLAME CURB® type XXX gypsum wallboard applied parallel to each side of 1-5/8” steel studs 24” o.c.

Face layer 1/2” PABCO® FLAME CURB® type XXX gypsum wallboard applied parallel to each side.

Joints staggered 24” each layer and side. Sound tested with 1-1/2” mineral fiber insulation in stud space.

NON LOAD BEARING

Fire Test:UC

50-54

Field Sound Test: ACI 1131a

2 Hr

NA

ASW 1105

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 1/2” PABCO® FLAME CURB® type XXX gypsum wallboard applied parallel to each side of 2-1/2” steel studs 24” o.c.

Face layer 1/2” PABCO® FLAME CURB® type XXX gypsum wallboard applied parallel to each side.

Joints staggered 24” each layer and side. Sound tested with 1-1/2” mineral fiber insulation in stud space.

NON LOAD BEARING

Fire Test: UC

50-54

Sound Test: CK 654-40

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

3-1/2˝

11-3/4˝

ASFW 0985 Area Separation Fire Wall

3-5/8˝

3-5/8˝

4-1/2˝

4-1/2˝

SJ 06-07-11/ Fire Rated Systems- PABCO® GypsumPage #50

"Quality to the Core" R

a division of PABCO® building products, LLC

FIRE RATED SYSTEMSAREA SEPARATION WALLS

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 55: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No.

Construction Detail DescriptionFire & Sound

Test Numbers

1 hr

NA

FC 4340

PABCO® GYPSUM WALLBOARD, STEEL CHANNEL JOISTS, PLYWOOD FLOOR

Base layer 1/2” PABCO®FLAME CURB® type XXX, or 1/2” FLAME CURB® Super C gypsum wallboard applied at right angles to resilient furring channels 16” o.c. Resilient furring channels applied at right angles to channel shaped, minimum 8” deep, 18 gage galvanized steel joists 16”o.c.Face layer 1/2” PABCO®FLAME CURB® type XXX, or 1/2” FLAME CURB® Super C gypsum wallboard applied at right angles to channels with end joints located midway between channels. Joints offset 24” from base layer joints. 3-1/2” glass fiber batt insulation in joist space. Floor of 5/8” T & G edge plywood applied at right angles to joists.STC tested with 1/4” carpet applied over a 3/8” foam pad.

Fire Test: NRCC A-4219.AAssembly FF-23

50- 54

Sound Test: NRCC B-3163.2IIC & Test: 69; NRCC B-3163.2

1 hr NA FC 4502

PABCO® GYPSUM WALLBOARD CEILING, STEEL CHANNEL JOISTS, PLYWOOD FLOOR

Base layer 1/2” PABCO® FLAME CURB® Super C gypsum wallboard applied at right angles to channel shaped, minimum 7” deep, 18 gage galvanized steel joists 24” o.c.Face layer 1/2” PABCO® FLAME CURB® Super C gypsum wallboard applied at right angles to joists. Joints offset from base layer joints. Steel joists supporting 5/8” T& G edge plywood floor applied at right angles to joists. For alternate floor systems, consult manufacturer.

Fire Test:Based on UL R3660-7, -8;UL R1319-133; UL R7094,90NK10635;UL Design L524

1.5 hr

NA -

Two layers 5/8” PABCO® FLAME CURB® Super C type C gypsum wallboard applied with long dimension perpendicular to resilient channels. Upper layer attached to resilient channels. Butt joints to be centered under resilient channels. Face layer installed perpendicular to resilient channels and attached to resilient channels through upper layer. All long edge joints in face layer boards to be offset from long edge joints in upper layer a min of 16 in. Butt joints of face layer to occur between resilient channels with each end of butted boards attached to upper board.

Fire Test: UL L527

2 hr NA FC 4750

PABCO® GYPSUM WALLBOARD, WOOD FLOOR, STEEL CHANNEL JOISTS, RIGID FURRING CHANNELS

Base layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to channel shaped, minimum 8” deep, 18 gage galvanized steel joists 24” o.c.Second layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to joists. Second layer joints offset 24” from base layer joints.Third layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to joists. Third layer joints offset 12” from second layer joints. Hat-shaped rigid furring channels 24” o.c. applied at right angles to joists over third layer.Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to furring channels. Joists supporting 3/4” T & G edge plywood floor applied at right angles to joists.

Fire Test: UL R4024, 02NK04478,UL Design L556;ULC Design M514

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

SJ 06-07-11/ Fire Rated Systems- PABCO® GypsumPage #51

"Quality to the Core" R

a division of PABCO® building products, LLC

FIRE RATED SYSTEMSFLOOR CEILING - STEEL FRAMED

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 56: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

2 hr 50-54 FC 2030

PABCO® GYPSUM WALLBOARD, STEEL JOISTS, CONCRETE SLAB

One layer 1/2” PABCO® FLAME CURB® type XXX, or PABCO® FLAME CURB® Super C gypsum wallboard applied at right angles to rigid furring channels 24” o.c. Gypsum board end joints located midway between continuous channels and attached to additional pieces of channel 54” long.

Furring channels attached to open web steel joists 24” o.c. supporting 3/8” rib metal lath or 9/16” deep 28 gage corrugated steel and 2-1/2” concrete slab measured from top of flute. Furring channels may be attached to 1-1/2” cold rolled carrying channels 48” o.c. suspended from joists.

(Two hour restrained and unrestrained.)

(See GA file No BM 3310)

Fire Test: UL R3501-28,UL Design G514;ULC Design I511

Sound Test: NGC 4075

3 hr 50-54 FC 3012

PABCO® GYPSUM WALLBOARD, STEEL JOISTS, CONCRETE SLAB

One layer 5/8” PABCO® FLAME CURB® Super C gypsum wallboard applied at right angles to furring channels 24” o.c. (double channels at end joints). 5/8” x 2-3/4” PABCO® FLAME CURB® type X gypsum wallboard strips over butt joints.

Furring channels wire tied to open web steel joist 24” o.c. supporting 3/8” rib metal lath and 2- 1/2” concrete slab.

(Three hour restrained and unrestrained.)

Fire Test: UL R1319-79; UL R3501,88NK21023,Based on UL R3660-7, -8; UL R2717-61,UL Design G512

Sound Test: Est. see FC 2030 (NGC 4075)

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

SJ 06-07-11/ Fire Rated Systems- PABCO® GypsumPage #52

FIRE RATED SYSTEMS

FIRE RATED SYSTEMS FLOOR-CEILING STEEL FRAMED (continued)

tothe ®

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 57: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

1 hr

NA

FC 5105

PABCO® GYPSUM WALLBOARD, RESILIENT CHANNELS, WOOD JOISTS

One layer 1/2” PABCO® FLAME CURB® Super C gypsum wallboard applied at right angles to resilient furring channels 24” o.c. Gypsum board end joints located midway between continuous channels and attached to additional pieces of channel 60” long.

Resilient channels applied at right angles to 2 x 10 wood joists 16” o.c. Wood joists supporting 19/32” plywood and 1” proprietary sanded gypsum underlayment.

STC rated with 3-1/2” glass fiber insulation in joist spaces and with carpet and pad. Second layer of 1/2” or 5/8” type X gypsum wallboard required to achieve 1 hour fire resistance rating when glass fiber insulation is used.

Fire Test: UL R6352,UL Design L502

55-59

Sound Test: G&H BW-10 MTIIC & Test: (73 C & P)G&H BW-10 MT

1 hr 55-59 FC 5107

PABCO® GYPSUM WALLBOARD, RESILIENT CHANNELS, WOOD JOISTS, GYPSUM FLOOR UNDERLAYMENT

One layer PABCO® 1/2” FLAME CURB® Super C gypsum wallboard applied at right angles to resilient furring channels 24” o.c. Gypsum board end joints located midway between continuous channels and attached to additional pieces of channel 54” long. Resilient furring channels applied at right angles to 2 x 10 wood joists 16” o.c. Wood joists supporting 19/32” plywood subfloor and 3/4” 1000 psi sanded gypsum floor underlayment.

Fire Test: UL R1319-65,UL Design L514

Field Sound Test: INTEST 5-761-3

1 hr

NA

FC 5111

PABCO® GYPSUM WALLBOARD, WOOD I-JOISTS,RESILIENT CHANNELS

Base layer PABCO® 1/2” FLAME CURB® type XXX, or PABCO® 1/2” FLAME CURB® Super C gypsum wallboard applied at right angles to resilient channels 16" o.c. Resilient channels applied at right angles to minimum 9-1/2” deep wood I-joists, with minimum 1-1/4” deep x 1-1/2” wide flanges and minimum 3/8” webs, 24” o.c.

Face layer PABCO® 1/2” FLAME CURB® type XXX, or PABCO® 1/2” FLAME CURB® Super C gypsum applied at right angles to channels. Face layer end joints located midway between channels and attached to base layer. Edge joints offset 24” from base layer edge joints. Wood I-joists supporting 5/8” oriented strand board applied at right angles to I-joists.

STC and IIC tested with 40 oz carpet over 1/4” foam pad.

Fire Test: NRCC A-4440.1 (Revised)

50-54

Sound Test: NRCC B-3150.2IIC & Test: (68 C & P)NRCC B-3150.2

1 hr 50-54 FC 5116

PABCO® GYPSUM WALLBOARD, WOOD JOISTS, RESILIENT CHANNELS, GLASS FIBER INSULATION

One layer 5/8” PABCO® FLAME CURB® Super C gypsum wallboard applied at right angles to resilient furring channels 24” o.c. Gypsum board end joints located midway between continuous channels and attached to additional pieces of channel 54” long. Resilient furring channels applied at right angles to 2 x 10 wood joists 16” o.c.

Wood joists supporting 5/8” interior plywood with exterior glue subfloor and 1-5/8” perlite-sand concrete reinforced with No. 19 SWG galvanized hexagonal wire mesh. 3” glass fiber insulation 0.90 pcf in joist space stapled to subfloor.

Fire Test: UL R3453-7Based on UL R3660-7, -8; R2717-61;Based on UL R7094,90NK10635;Based on UL R8742,88NK22591,UL Design L516Sound Test: KAL L 224-28-65IIC & Test: (74 C & P)KAL L 224-27-65

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

SJ 06-14-11/ Fire Rated Systems- PABCO® GypsumPage #53

"Quality to the Core" R

a division of PABCO® building products, LLC

FIRE RATED SYSTEMSFLOOR CEILING - WOOD FRAMED

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 58: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

1 hr FC 5120

PABCO® GYPSUM WALLBOARD, WOOD JOISTS, RESILIENT CHANNELS, GLASS FIBER INSULATION

One layer PABCO® 1/2” FLAME CURB® type XXX, or PABCO® 1/2” FLAME CURB® Super C gypsum wallboard applied at right angles to resilient furring channels 24” o.c. Resilient channels applied at right angles to 2 x 10 wood joists 16" o.c. Wood joists supporting 5/8" interior plywood with exterior glue subfloor and 3/8" particleboard, 1.5 psf.

3-1/2" glass fiber insulation batts, 0.7 pcf, friction fit in joist cavities, supported by alternately every 12" by wire ords and resilient furring channels.

Sound tested with carpet and pad and with insulation stapled to joists.

Fire Test: FM FC-181, 8-31-72

50-54

Sound Test: G&H OC-3MT, 10-31-71

IIC & Test:(73 C & P)G&H OC-3MT, 10-31-71

1 hr 45-49 FC 5241

PABCO® GYPSUM WALLBOARD, WOOD I-JOISTS, RESILIENT CHANNELS

Base layer PABCO® 1/2” FLAME CURB® type XXX, or PABCO® 1/2” FLAME CURB® Super C gypsum wallboard applied at right angles to resilient channels 16” o.c. Resilient channels applied at right angles to minimum 9-1/2” deep wood I-joists, with minimum 1-1/4” deep x 1-1/2” wide flanges and minimum 3/8” webs, 24” o.c.

Face layer PABCO® 1/2” FLAME CURB® type XXX, or PABCO® 1/2” FLAME CURB® Super C gypsum wallboard applied at right angles to channels. Face layer end joints located midway between channels and attached to base layer. Edge joints offset 24” from base layer edge joints. Wood I-joists supporting 5/8” oriented strand board applied at right angles to I-joists.

Fire Test: NRCC A-4440.1 (Revised)

Sound Test: NRCC B-3150.1IIC & Test: 40 (68 C & P)NRCC B-3150.1,NRCC B-3150.2

1 hr 45-49 FC 5250

PABCO® GYPSUM WALLBOARD, WOOD JOISTS, RESILIENT CHANNELS

One layer PABCO® 1/2” FLAME CURB® type XXX, or PABCO® 1/2” FLAME CURB® Super C gypsum applied at right angles to resilient furring channels 24” o.c. Gypsum board end joints located midway between continuous channels and attached to additional pieces of channel 60” long. Resilient furring channels applied at right angles to 2 x 10 wood joists 16” o.c.

Wood joists supporting 1” nominal wood subfloor and 1” nominal wood finish floor, or 19/32” plywood finished floor with long edges T & G and 15/32” interior plywood with exterior glue subfloor perpendicular to joists with joints staggered.

Fire Test: UL R2717-29,UL Design L502;ULC Design M501

Sound Test: RAL TL64-155IIC & Test: 39 (67 C & P)See FC 5240(CK 6512-6)

1 hr 35-39 FC 5415

PABCO® GYPSUM WALLBOARD, WOOD JOISTS, RESILIENT CHANNELS

One layer 5/8” PABCO® FLAME CURB® Super C gypsum wallboard applied at right angles to resilient furring channels 16” o.c.

Gypsum board end joints located midway between continuous channels and attached to additional pieces of channel 72” long. Resilient furring channels applied at right angles to 2 x 10 wood joists 24” o.c. Wood joists supporting 3/4” nominal interior plywood with exterior glue T & G subfloor perpendicular to joists with joints staggered. Underside of T & G joints covered between joist spaces with 6” x 22-1/2” x 5/8” type X gypsum wallboard battens attached to flooring.

Fire Test: UL R5229-2,UL Design L513

Sound Test: Estimated

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

SJ 06-14-11/ Fire Rated Systems- PABCO® GypsumPage #54

FIRE RATED SYSTEMS FLOOR-CEILING WOOD FRAMED (continued)

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 59: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

1 hr 35-39 FC 5406

PABCO® GYPSUM WALLBOARD, WOOD JOISTS

Base layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to 2 x 10 wood joists 24” o.c.

Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to joists. Joints offset 24” from base layer joints. Wood joists supporting 1/2” plywood with exterior glue applied at right angles to joists.

Ceiling provides one hour fire resistance protection for framing, including trusses.

Fire Test: FM FC 172;ITS.

Sound Test: Estimated

1 hr 35-39 FC 5407

PABCO® GYPSUM WALLBOARD, WOOD I-JOISTS,

Base layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to wood I-joists 24” o.c.

Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to I-joists. Joints offset 24” from base layer joints.

Wood I-joists supporting 1/2” wood structural panels applied at right angles to joists.

Ceiling provides one hour fire resistance protection for I-joists.

Fire Test:FM FC 172,ITS

Sound Test:Estimated

1 hr 35-39 FC 5410

PABCO® GYPSUM WALLBOARD, WOOD JOISTS

One layer 1/2” PABCO®FLAME CURB® type XXX, or 1/2” FLAME CURB® Super C gypsum wallboard applied at right angles to 2 x 10 wood joists 16” o.c.

Wood joists supporting 1” nominal T & G wood subfloor and 1” nominal wood finish floor, or 19/32” plywood finished floor with long edges T & G, and 15/32” interior plywood with exterior glue subfloor perpendicular to joists with joints staggered.

Fire Test: UL R1319-66,UL Design L512;UL R3501-45,UL Design L522;UL R2717-38,UL Design L503;UL R3543-6,UL Design L519;ULC Design M502

Sound Test: NGC 4024, IIC & Test: 32 (66 C & P)NGC 5032

1 hr 35-39 FC 5420

PABCO® GYPSUM WALLBOARD, WOOD JOISTS

One layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to 2 x 10 wood joists 16” o.c.

Wood joists supporting 1” nominal wood subfloor and 1” nominal wood finish floor, or 19/32” plywood finished floor with long edges T & G and 15/32” interior plywood with exterior glue subfloor perpendicular to joists with joints staggered.

Fire Test: UL R3501-5, 9,UL R1319-2, 3;UL Design L 501;ULC Design M500

Sound Test: See FC 5410(NGC 4024)IIC & Test: 32 (66 C & P)NGC 5032

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

SJ 06-14-11/ Fire Rated Systems- PABCO® GypsumPage #55

FIRE RATED SYSTEMS FLOOR-CEILING WOOD FRAMED (continued)

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 60: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

1 hr NA FC 5520

PABCO® GYPSUM WALLBOARD, WOOD TRUSSES, WOOD STRUCTURAL PANELS, GYPSUM FLOOR TOPPING, RESILIENT CHANNELS, GLASS OR MINERAL FIBER BATT OR LOOSE FILL INSULATION, CEILING DAMPEROne layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to resilient furring channels 12” o.c. Gypsum board end joints located midway between continuous channels and attached to additional pieces of channel 60” long located 3” back on either side of end joint. Resilient channels applied at right angles to 18” deep parallel chord wood trusses 24” o.c. Glass or mineral fiber batt insulation stapled to subfloor or loose fill insulation applied directly over gypsum board.Wood trusses supporting 23/32” wood structural panel subfloor, long edges T & G, applied at right angles to trusses. Either 3/4” gypsum floor topping or 15/32” wood structural panel underlayment applied over subfloor.Optional ceiling damper (refer to manufacturer for information on the type of damper).

Fire Test: UL R7094, 07NK11121,UL Design L592;WFCi 07002C/07048

1 hr NA FC 5515

PABCO® GYPSUM WALLBOARD, WOOD TRUSSES One layer 5/8” PABCO® FLAME CURB® Super C type C gypsum wallboard applied at right angles to rigid furring channels 24” o.c. Gypsum board end joints located midway between continuous channels and attached to additional pieces of channel 60” long.Rigid furring channels applied at right angles to 12” deep parallel chord wood trusses 24” o.c. Wood trusses supporting 3/4” nominal interior plywood with exterior glue, T & G edges, applied at right angles to trusses. End joints staggered 48”.Consult the gypsum board manufacturer for truss details.

Fire Test:UL R9500-1,80NK15492;UL R2717-61;UL Design L528

2 hr NA FC 5751

PABCO® GYPSUM WALLBOARD, WOOD FLOOR, WOOD TRUSSES, RIGID FURRING CHANNELSBase layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to 18” deep parallel chord wood trusses 24” o.c. Second layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to trusses. Second layer joints offset 24” from base layer joints. Third layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to trusses. Third layer joints offset 12” from second layer joints. Hat-shaped rigid furring channels 24” o.c. applied at right angles to trusses over third layer. Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to furring channels.Wood trusses supporting 3/4” T & G edge plywood floor applied at right angles to trusses. Ceiling provides two-hour fire resistance protection for wood framing.

Fire Test:UL R4024,00NK26545,UL Design L556; ULC Design M514

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

SJ 06-14-11/ Fire Rated Systems- PABCO® GypsumPage #56

FIRE RATED SYSTEMSFLOOR-CEILING WOOD FRAMED (continued)

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 61: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

2 hr NA FC 5710

PABCO® GYPSUM WALLBOARD, WOOD FLOOR, WOOD JOISTS, RESILIENT CHANNELS

Base layer 5/8” PABCO® FLAME CURB® Super C type C gypsum wallboard applied at right angles to 2 x 10 wood joists 16” o.c. Resilient channel 24” o.c. applied at right angles to wood framing through base layer. Double channel installed at face layer end joints.

Face layer 5/8” PABCO® FLAME CURB® Super C type C gypsum wallboard applied at right angles to resilient furring channels. Wood joists supporting 15/32” plywood subfloor and 19/32” plywood finish floor applied at right angles to joists with joints staggered. Consult the gypsum board manufacturer for other flooring options.

Fire Test: UL R1319-114,UL Design L511

2 hr NA FC 5724

PABCO® GYPSUM WALLBOARD, WOOD FLOOR, WOOD JOISTS, RESILIENT CHANNELS

Base layer 5/8” PABCO® FLAME CURB® Super C type C gypsum wallboard applied at right angles to 2 x 10 wood joists 16” o.c. Resilient furring channels 24” o.c. applied at right angles to joists through base layer at each joist.

Face layer 5/8” PABCO® FLAME CURB® Super C type C gypsum wallboard applied at right angles to resilient furring channels. Double channel installed at face layer end joints. Wood joists supporting 1” nominal T & G wood subfloor and 1” nominal wood finish floor or 19/32” plywood finished floor with long edges T & G and 15/32” interior plywood with exterior glue subfloor perpendicular to joists with joints staggered.

Fire Test:UL R2717-35, UL Design L505;ULC Design M503

2 hr NA FC 5750

PABCO® GYPSUM WALLBOARD, WOOD FLOOR, WOOD I-JOISTS, RIGID FURRING CHANNELS

Base layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to 9-1/2” deep wood I-joists 24” o.c.

Second layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to I-joists. Second layer joints offset 24” from base layer joints.

Third layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to I-joists. Third layer joints offset 12” from second layer joints.

Hat-shaped rigid furring channels 24” o.c. applied at right angles to I-joists over third layer.

Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at rightangles to furring channels.

Wood I-joists supporting 3/4” T & G edge plywood floor applied at right angles to I-joists.

Ceiling provides two-hour fire resistance protection for wood framing.

Fire Test: UL R4024, 00NK26545,UL Design L556;ULC Design M514

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

SJ 06-14-11/ Fire Rated Systems- PABCO® GypsumPage #57

FIRE RATED SYSTEMS

FIRE RATED SYSTEMSFLOOR-CEILING WOOD FRAMED (continued)

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 62: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

1 HR NA RC 2608

PABCO® GYPSUM WALLBOARD, WOOD ROOF TRUSSES, RESILIENT CHANNELS, GLASS OR MINERAL FIBER INSULATION, CEILING DAMPER

One layer 5/8” FLAME CURB® Super C type C gypsum wallboard applied at right angles to resilient furring channels 16” o.c. (12” o.c. when insulation is draped over channels). Gypsum board end joints attached with screws 8” o.c. to additional pieces of channel 60” long located 3” back on either side of end joint.

Resilient channels applied at right angles to bottom chord of pitched wood trusses 24” o.c. Optional glass fiber or mineral fiber batt insulation secured to wood structural panels or applied directly over gypsum board. Trusses supporting 15/32” wood structural panels applied at right angles to trusses. Optional ceiling damper (refer to manufacturer for information on the type of damper).

Fire Test: UL R7094, 07NK11121, UL Design P549;WFCi 07002C/07048

1 HR NA RC 2602

PABCO® GYPSUM WALLBOARD, WOOD TRUSSES

Base layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to wood roof trusses 24” o.c. Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to trusses. Joints offset 24” from base layer joints. Wood trusses supporting 1/2” wood structural panels applied at right angles to trusses. Appropriate roof covering.

Ceiling provides one hour fire resistance protection for trusses.

Fire Test: FM FC 172;ITS

2 HR NA RC 2750

PABCO® GYPSUM WALLBOARD, RIGID FURRING CHANNELS WOOD JOISTS or WOOD I-JOISTS, ROOF COVERING

Base layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to either 2 x 8 wood joists or 9-1/2” deep wood I-joists 24” o.c.

Second layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to joists or I-joists. Second layer joints offset 24” from base layer joints.

Third layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to joists or I-joists. Third layer joints offset 12” from second layer joints. Hat-shaped rigid furring channels 24” o.c. applied at right angles to joists or I-joists over third layer.

Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to furring channels. Wood joists or I-joists supporting 3/4” T & G edge plywood applied at right angles to joists or I-joists. Appropriate roof covering.

Ceiling provides two-hour fire-resistance protection for wood framing.

Fire Test: UL R4024, 00NK26545,UL R4042, 03NK11206;UL Design L556;ULC Design M514

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

SJ 06-14-11/ Fire Rated Systems- PABCO® GypsumPage #58

"Quality to the Core" R

a division of PABCO® building products, LLC

FIRE RATED SYSTEMSROOF CEILING - WOOD FRAMED

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 63: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

2 HR NA RC 2751

PABCO® GYPSUM WALLBOARD, WOOD ROOF TRUSSES, RIGID FURRING CHANNELS

Base layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to wood roof trusses 24” o.c.

Second layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to trusses. Second layer joints offset 24” from base layer joints.

Third layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to trusses. Third layer joints offset 12” from second layer joints. Hat-shaped rigid furring channels 24” o.c. applied at right angles to trusses over third layer.

Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied at right angles to furring channels.

Wood trusses supporting 3/4” T & G edge wood structural panels applied at right angles to trusses. Appropriate roof covering.

Ceiling provides two-hour fire-resistance protection for wood framing.

Fire Test: UL R4024, 00NK26545,UL Design L556;ULC Design M514

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

SJ 06-14-11/ Fire Rated Systems- PABCO® GypsumPage #59

FIRE RATED SYSTEMS ROOF-CEILING Wood Framed (continued)

tothe ®

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 64: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No

Construction Detail-

Light Tubular ColumnDescription

Fire & SoundTest

Numbers

1 hr NA CM 1452

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 1/2” PABCO® FLAME CURB® type XXX gypsum wallboard applied without horizontal joints to 1-5/8” steel studs located at each corner of TS 4x4x0.188 tube steel column.

Face layer 1/2” PABCO® FLAME CURB® type XXX gypsum wallboard applied without horizontal joints to studs. Metal cornerbead applied to all corners. Joint compound 1/16” thick applied over corner bead.

Fire Test: UL NC505, 77NK1747;UL Design X528

1 hr NA CM 1851

PABCO® GYPSUM WALLBOARD, STEEL STUDS

One layer 5/8” PABCO® FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied without horizontal joints and parallel to 1-5/8” steel studs located at each corner of TS 8x8x0.250 tube steel column.

Steel cornerbead, 1-1/2” flanges, applied. Joint compound 1/16” thick applied over corner bead.

Fire Test: UL NC505, 77NK1747;UL Design X528

1.5 hr

NA NA

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Two layers of 1/2" PABCO® FLAME CURB® Super C type PG -C gypsum wallboard applied vertically to 1-5/8" steel studs and channels, furred from 4-1/2" min OD steel pipe column (min wall thickness 0.109” and min 5.1 lbs/ft weight). Channels tied to column with No. 18 SWG tie wire.

Steel cornerbead, 1-1/4” legs, applied. Joint compound 1/16” thick applied over corner beads, joints, and surfaces of wallboard.

Fire Test:UL X531

2 hr NA CM 2455

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 1/2” PABCO® FLAME CURB® type XXX, or 1/2” FLAME CURB® Super C gypsum wallboard applied without horizontal joints to 1-5/8” steel studs located at each corner of TS 4x4x0.188 tube steel column .

Second layer 5/8” PABCO® FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied without horizontal joints.

Face layer 5/8” PABCO® FLAME CURB® type X gypsum wallboard, 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied without horizontal joints to studs. Metal corner bead applied to all corners. Joint compound 1/16” thick applied over corner bead

Fire Test: UL NC505, 77NK1747;UL NC505; UL Design X528

Column 10WF-49

1 hr NA CM 1001

PABCO® GYPSUM WALLBOARD, STEEL STUDS

One layer 1/2” PABCO® FLAME CURB® type XXX, or 1/2” FLAME CURB® Super C gypsum wallboard applied without horizontal joints to 1-5/8” steel studs located at each corner of W10x49 column. Metal corner bead applied to all corners.

Joint compound 1/16” thick applied over corner bead.

Fire Test: UL NC505, 77NK1747;UL Design X528

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

SJ 06-07-11/ Fire Rated Systems- PABCO® GypsumPage #60

"Quality to the Core" R

a division of PABCO® building products, LLC

FIRE RATED SYSTEMSCOLUMNS - Noncombustible

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 65: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

STC Rating

GA File No

Construction Detail-

Column 10WF-49Description

Fire & SoundTest

Numbers

2 hr NA CM 2017

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 5/8” PABCO® FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied without horizontal joints to 1-5/8” steel studs located at each corner of W10x49 column.

Face layer 1/2” PABCO® FLAME CURB® Super C type PG -C gypsum wallboard applied without horizontal joints to studs. Metal corner bead applied to all corners.

Joint compound 1/16” thick applied over corner bead

Fire Test: UL NC505, 77NK1747;UL Design X528

3 hr NA CM 3120

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 5/8” PABCO® FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied to 1-5/8” steel studs located at each corner of W10x49 column.

Second layer 5/8” PABCO® FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied to studs.

Face layer 5/8” PABCO® FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied to studs. Metal corner bead applied at all corners.

Fire Test: UL R2717-31, UL Design X509;UL R3501-36, UL Design X510;ULC Design Z502

4 hr NA NA

Base Layer and Second layer 5/8” PABCO® FLAME CURB® Super C Type C gypsum wallboard applied to 1-5/8” steel studs located at each corner of W10x49 column.

Third layer and Face layer 5/8” PABCO® FLAME CURB® Super C Type C gypsum wallboard applied to 2" x 2" sheet metal angles placed at the corners of the second layer of wallboard.

Metal corner bead applied at corners and covered with joint compound treatment.

Fire Test:UL Design X501

Column 14WF-228

2 hr NA CM 2110

PABCO® GYPSUM WALLBOARD, STEEL STUDS

One layer 1/2” PABCO® FLAME CURB® type XXX, or 1/2” FLAME CURB® Super C gypsum wallboard attached to 1-5/8” steel studs located at each corner of heavy steel W14x228 columns. 1-1/4” metal corner bead applied by crimping 6” o.c.

Fire Test: UL R3501-58,UL Design X520;ULC Design X520

3 hr NA CM 3130

PABCO® GYPSUM WALLBOARD, STEEL STUDS

Base layer 1/2” PABCO® FLAME CURB® type XXX, or 1/2” FLAME CURB® Super C gypsum wallboard applied to 1-5/8” steel studs located at corners of heavy steel W14x228 column.

Face layer 1/2” PABCO® FLAME CURB® type XXX, or 1/2” FLAME CURB® Super C gypsum wallboard applied to studs. 1” corner bead applied.

Fire Test: UL R3501-61,UL Design X513;ULC Design X513

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

SJ 06-07-11/ Fire Rated Systems- PABCO® GypsumPage #61

FIRE RATED SYSTEMSCOLUMNS -Noncombustible (continued)

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 66: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

FIRE Rating

GA File No Construction Detail Description

Fire & SoundTest

Numbers

1 hr BM 1137

PABCO® GYPSUM WALLBOARD, STEEL FRAME

Base layer 1/2” PABCO® FLAME CURB® Super C type PC-C gypsum wallboard applied to beam cage.

Face layer 1/2” PABCO® FLAME CURB® Super C type PC-C gypsum wallboard applied to beam cage. Joints offset from base layer joints.

Beam cage fabricated from No. 24 gage 7/8” x 1-3/8” steel angles screw attached to steel joists at beam top flange and No. 25 gage 2-1/2” steel runners hooked over beam lower flange and supporting 1-5/8” steel studs 24” o.c. Minimum beam size W8x15.

(One hour unrestrained beam.)

Fire Test: UL R1319-133;Based on UL R3660-7 & -8;UL Design L524

2 hr BM 2120

PABCO® GYPSUM WALLBOARD, STEEL FRAME

Base layer 5/8” PABCO® FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied to beam cage.

Face layer 5/8” PABCO® FLAME CURB® type X gypsum wallboard, 5/8”WATER CURB® type X backing board, or 5/8” PABCO® type X gypsum sheathing applied to beam cage.

Beam cage fabricated from horizontally installed steel angles (25 gage steel having 1” and 2” legs). “U” shaped brackets formed of 25 gage “U” shaped steel channels (1-11/16” wide with 1” legs) 24” o.c. suspended from upper angles.

Minimum beam size W8x24. (Two hour restrained or unrestrained beam.)

Fire Test: UL R4024-5,UL Design N501;ULC Design O501

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

tothe ®

SJ 06-07-11/ Fire Rated Systems- PABCO® GypsumPage #62

"Quality to the Core" R

a division of PABCO® building products, LLC

FIRE RATED SYSTEMSBEAMS & GIRDERS - Noncombustible

Please refer to the referenced test report for construction details. Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.

Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to [email protected]. www.pabcogypsum.com

Page 67: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

Quality Matters.

Quality to the Core®

At PABCO® Gypsum, quality is a serious part of our business; a core fundamental value.

It’s what sets us apart from our competitors, a core key-success-factor, a commitment to you.

It’s why customers ask for our products, and why they come back year after year.

PABCO® Gypsum, Commitment to the Core™

Page 68: a division of PABCO® building products, LLC … GUIDE FIRE & SOUND RATED SYSTEMS a division of PABCO® building products, LLC to the ® MGM CityCenter, Las Vegas, NV: Utilized approximately

a division of PABCO® building products, LLC

Technical Service • Literature • Samples

[email protected]

Limited Warranty: PABCO® Building Products, LLC, warrants that on the date the gypsum board is shipped from its manufacturing plant the gypsum board is free from defects in materials and manufacture. NOTWITHSTANDING THE FOREGOING, IT IS THE RESPONSIBILITY OF THE GYPSUM BOARD APPLICATOR TO NOTIFY PABCO BUILDING PRODUCTS, LLC, IN WRITING WITHIN TWENTY FOUR (24) HOURS OF DISCOVERY OF ANY VISIBLY DEFECTIVE GYPSUM BOARD PRIOR TO SUCH VISIBLY DEFECTIVE GYPSUM BOARD BEING APPLIED; FAILURE TO DO SO MAY FURTHER LIMIT OR VOID THE RESPONSIBILITIES OF PABCO BUILDING PRODUCTS, LLC, UNDER THIS WARRANTY. This warranty will remain in place for one year from the date of shipment from the manufacturing plant. THIS EXPRESS WARRANTY IS THE EXCLUSIVE WARRANTY PROVIDED BY PABCO® BUILDING PRODUCTS, LLC, AND SUPERSEDES ANY PRIOR, CONTRARY OR ADDITIONAL REPRESENTATIONS, WHETHER ORAL OR WRITTEN. PABCO® BUILDING PRODUCTS, LLC, HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES – WHETHER EXPRESS, IMPLIED, OR STATUTORY – INCLUDING ANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

If the gypsum board fails to conform to the foregoing warranty in Paragraph 1 and such nonconformity is not due to misuse or improper maintenance or storage, Buyer shall notify PABCO® Building Products, LLC, in writing, and within 60 days of discovery, PABCO® Building Products, LLC, shall provide, at its sole and absolute discretion, one of the following: (i) repair or replacement of any nonconforming or defective gypsum wallboard; or (ii) credit or full refund of the purchase price. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER FOR ANY BREACH OF WARRANTY.

IN NO EVENT SHALL PABCO® BUILDING PRODUCTS, LLC, BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, or strict liability in tort or under any other legal theory.

Trademarks: The following trademarks used herein are owned by Pacific Coast Building Products and licensed to PABCO® Gypsum: PABCO®, PABCORE®, FLAME CURB®, WATER CURB®, MOLD CURB®, Quality to the Core®, ABUSE CURB™.

Notice: Products described herein may not be available in all geographic markets. Consult your PABCO® Gypsum sales representative for information or call our Technical Services.

Current updated information is available on our website: www.pabcogypsum.com. The information in this publication may change without notice.

PABCO® Gypsum Construction Guide - Fire & Sound Rated SystemsCopyright © 2009, 2011 • 2nd Edition PABCO® Gypsum • a division of PABCO® Building Products, LLCPO Box 417094 • Rancho Cordova • CA • 95741 www.pabcogypsum.com; 7-2011; 3M

tothe ®

MGM CityCenter, Las Vegas, NV: utilized approximately 18 mil sf of PABCO® Gypsum wallboard