a pl7 installation and contents startup asousa/sind/schneider/pl7-installation-startup...ld yes yes...

Download A PL7 Installation and Contents Startup asousa/sind/schneider/PL7-Installation-Startup...LD yes yes yes IL yes yes yes ST no yes yes Sections yes yes yes Function no no yes modules

Post on 23-Apr-2018

218 views

Category:

Documents

4 download

Embed Size (px)

TRANSCRIPT

  • ___________________________________________________________________________1

    PL7 Installation and ContentsStartup Guide

    Section Page

    A

    1 General 1/1

    1.1 Document Structure 1/1

    1.2 Presentation of PL7 Software 1/2

    1.3 Developments 1/4

    2 Software Setup 2/1

    2.1 Configuring the Terminal 2/12.1-1 Minimum Configuration 2/12.1-2 Typical Configuration 2/1

    2.2 PL7 Software Installation 2/22.2-1 Preliminary Operations 2/22.2-2 The Software Packages and Their Contents 2/32.2-3 Installation Procedure 2/42.2-4 PL7 Directories and Files 2/5

    2.3 Installing Updates and Upgrades 2/6

    2.4 Installing Drivers 2/7

    2.5 Execution 2/10

    2.6 Uninstalling PL7 2/10

    2.7 Errors 2/11

  • ___________________________________________________________________________

    2

    PL7 Installation and ContentsStartup Guide

    Section Page

    A

    2.8 Automatic Installation 2/122.8-1 Call Syntax 2/122.8-2 Syntax of Command File Fields (*.INI) 2/122.8-3 Error Handling 2/14

    3 Hardware Setup 3/1

    3.1 Connections 3/13.1-1 PC PLC connection 3/13.1-2 FT PLC connection 3/2

  • General 1

    ___________________________________________________________________________1/1

    ASection 1

    1 General

    1.1 Document Structure

    This manual describes PL7 Micro, Junior, Pro and Pro Dyn software on a PC with oneof the following operating systems :

    i Windows 95, Windows 98

    i Windows NT 4.0

    Part A deals with hardware and software setup.

    Part B describes the functions and uses of the software.

    Throughout this document, the term PL7 software is used to refer to PL7 Micro, Junior,Pro or Pro Dyn without differentiation.

    For further information please consult other manuals with the reference TLX DOC PL7 33 E :

    i Reference Manual (describes the languages and instructions)

    i TSX37 Application-Specific Functions Manual (describes the software setup forTSX37 application-specific functions)

    i TSX57 Application-Specific Functions Manual (describes the software setup forTSX57 application-specific functions)

    i TSX37-TSX57 Communication Manual (describes communication)

    i PL7-2 Converter Manual (describes the conversion of a PL7-2 application to PL7 Micro,Junior or Pro)

    i PL7-3 Converter Manual (describes the conversion of a PL7-3 application to PL7Junior or Pro)

    i ORPHEE Converter Manual (describes the conversion of an ORPHEE application toPL7 Junior or Pro)

    i Runtime Screens Manual (describes the installation of the runtime screens)

  • 1/2___________________________________________________________________________

    A

    1.2 Presentation of PL7 Software

    PL7 Micro, Junior and Pro software packages are programming and debugging toolsfor TSX Micro and TSX Premium PLCs.

    PL7 Pro Dyn software is an operating tool (supervision, diagnostics and maintenance)for TSX Micro and TSX Premium PLCs. It cannot be used to create or modify anapplication.

    The software is available in three different packages :

    i software package : used to install PL7 V3.3 software

    i software update package : used to update an older version to a new version (forexample : PL7 Micro V1.0 to PL7 Micro V3.3)

    i software upgrade package : used to upgrade an older version to a new version withhigher-level functions (for example : PL7 Micro V1.0 to PL7 Junior V3.3)

    PL7 software package references

    TLX CD PL7M P 33 M and EF : PL7 Micro

    TLX CD PL7J P 33 M and EF : PL7 Junior

    TLX CD PL7P P 33 M and EF : PL7 Pro

    TLX CD PL7PD P 33 M and EF : PL7 Pro Dyn

    TLX RCD PL7M P 33 M and EF : Update for PL7 Micro to PL7 Micro, new version

    TLX RCD PL7J P 33 M and EF : Update for PL7 Junior to PL7 Junior, new version

    TLX RCD PL7P P 33 M and EF : Update for PL7 Pro to PL7 Pro, new version

    TLX RCD PL7PD P 33 M and EF : Update for PL7 ProDyn V3.x to PL7 ProDyn , newversion

    TLX UCD PL7J P 33 M and EF : Upgrade for PL7 Micro or Junior V*.* to PL7 Junior,new version

    TLX UCD PL7P P 33 M and EF : Upgrade for PL7 Junior V*.* to PL7 Pro, newversion

    A PL7 software package comprises :

    i a PL7 software installation CD-ROM

    i a CD-ROM containing the different versions of operating systems for TSX 37 andTSX 57

    i a TSX 07/37/57 PC UNI-TE terminal port cable (reference TSX PCU 1030, notsupplied with updates and upgrades)

    i a PL7 installation and startup guide (this manual)

    i a product identification number : this number should not be discarded, as it is requiredwhenever PL7 Micro, Junior, Pro or ProDyn software is being installed, updated orupgraded

    i a CD-ROM containing French/English documentation

  • General 1

    ___________________________________________________________________________1/3

    A

    Note :The floppy disks for installing PL7 software can be ordered separately.

    Functions of PL7 software

    PL7 Micro PL7 Junior PL7 Pro PL7 Pro Dyn

    Programming TSX Micro TSX Micro and TSX Micro and noTSX Premium TSX Premium

    Language display

    G7 CHART yes yes yes

    MACROS no TSX Premium TSX Premium

    LD yes yes yes

    IL yes yes yes

    ST no yes yes

    Sections yes yes yes

    Function no no yesmodules

    Debugging yes yes yes no

    Adjustment yes yes yes yes

    Diagnostics no yes yes yes

    Runtime no no creation/use creation/usescreens

    DFB types no use creation/use no

    Diagnostic no no TSX/PCX/PMX 57 displayDFB

    Storage of TSX Premium TSX Premium TSX Premiumsymbols inthe PLC

    Application yes yes yes yesdoc. file

  • 1/4___________________________________________________________________________

    A

    1.3 Developments

    PL7 software can be used to access applications at all levels.

    PL7 Micro, Junior and Pro software can be used to create, read and modify applicationswithout changing the version or to convert them to version V3 by simply reconfiguringthe processor (select the V3 processor during hardware configuration).

    PL7 Pro Dyn software can be used to access an application in read-only mode, butcannot be used to convert an application to version V3.

    Comment :

    Conversion cannot be reversed. The application, once converted to be executedby a V3.0 processor, can no longer be executed by a processor of an earlier version.

    Note :V1.0/V1.5/V2.0 PLC processors cannot execute V3 applications.

    PL7 software Applications Processors

    V1.0, V1.5 andV2.0 levelversions

    V3.0 or V3.3level versions

    YES YES

    YES

    YES YES

    NO

    NO

    PCMCIAmemory

  • General 1

    ___________________________________________________________________________1/5

    A

    Main developments in PL7 V3.3 software

    The new functions provided by PL7 Micro, PL7 Junior, PL7 Pro and PL7 ProDynproducts in these new versions are the following :

    - functional view and function modules- partial protection of an application (access rights for the sections)- storage of the symbols database in the PLC- PL7 used in server mode (Automation OLE)- development of the variables editor and LD editor- import/export NIOF- FIPIO developments and other configuration developments (1/2 racks, newmodules, etc)- user function blocks (Derived Function Block) written in LD- functions for the Diagnostics offer (Diag DFB)- display of the documentation file on screen- Runtime screens : diagnostics viewer, setting screen parameters, etc.

    PL7 PL7 PL7 PL7 TSX TSXMicro Junior Pro ProDyn Micro Premium

    Partial protection of sections x x x x x

    Function modules x x x

    DFB creation in LD x x

    DFB use in LD x x x x

    Import/Export NIOF x x x

    Storage of symbols in PLC x x x x

    PL7 in server mode x x

    Half racks x x x x

    Data editor developments x x x x

    Fipio developments x x x x

    Import/Export Grafcet section x x x

    Documentation file display x x x x

    LD editor developments x x x x

    Runtime Screens developments x x

    Diagnostic functions x x x

  • 1/6___________________________________________________________________________

    A

  • Software Setup 2

    ___________________________________________________________________________2/1

    ASection 2

    2 Software Setup

    2.1 Configuring the Terminal

    2.1-1 Minimum Configuration

    Processor 486 DX5 133 MHz

    System Windows 95

    RAM 32 Mb

    Drives Hard disk 50 Mb for the software25 Mb for the temporary directories

    Floppy disk

    Ports COM serial port available for connection to the PLC (COM1 toCOM4)Parallel printer port (LPT1 to LPT4)

    Monitor VGA

    2.1-2 Typical Configuration

    Processor Pentium 166

    Systems Windows 95 / 98 Windows NT 4.0

    RAM 32 Mb 48 Mb

    Drives Hard disk 50 Mb for the software25 Mb for the temporary directories

    CD-ROMFloppy disk

    Ports COM serial port available for connection to the PLC (COM1 toCOM4)Parallel printer port (LPT1 to LPT4)

    Monitor At least VGA (SVGA with color management on 24 bits isrecommended)

    Note :The characteristics described concern configuration for the installation of PL7 software only. If PL7is used simultaneously with other software packages a more powerful configuration may be required.

  • 2/2___________________________________________________________________________

    A

    2.2 PL7 Software Installation

    2.2-1 Preliminary Operations

    Before installing PL7 software on disk, read the license and guarantee certificatesconcerning the restrictions which apply to copying and installing the software.

    PL7 can be installed from the CD-ROM. The floppy disks for installing PL7 softwarecan be ordered separately. If