a t f analytical task force for chemical distress bra bersuch

22
A T F Analytical T ask F orce for Chemical Distress BRA Bersuch

Upload: griselda-rausch

Post on 05-Apr-2015

105 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: A T F Analytical Task Force for Chemical Distress BRA Bersuch

A T F

Analytical Task Force for Chemical Distress

BRA Bersuch

Page 2: A T F Analytical Task Force for Chemical Distress BRA Bersuch

2

Page 3: A T F Analytical Task Force for Chemical Distress BRA Bersuch

3

» Task

» location

» devices

» Alarm

Page 4: A T F Analytical Task Force for Chemical Distress BRA Bersuch

4

Three Step System:

Federal Task forces, Disaster, special situations like terrorism

State special units either financed from the state or from the federal government, more complex incidents

Municipal local fire brigade, normal incident situations

Page 5: A T F Analytical Task Force for Chemical Distress BRA Bersuch

5

Task:

• Detection and Identification• Monitoring. • Evaluation.• Risk assessment.• Consulting service.• Consulting service on the spot.• Consulting service for medical personnel (eg. MEMPLEX).

Page 6: A T F Analytical Task Force for Chemical Distress BRA Bersuch

6

ATF in Germany

– BF Hamburg

– BF Mannheim

– LKA Berlin (Police)

– IdF Sachsen – Anhalt

– Three more locations in planning

Page 7: A T F Analytical Task Force for Chemical Distress BRA Bersuch

7

(HGDA2) GDA2 Hazardous Goods Detection Array2

GC-MS Gaschromatograph-Massspectrometer

FTIR Fourier-transformed-Infraredspectrometer

1. SIGIS 2 2. HazMat ID

Page 8: A T F Analytical Task Force for Chemical Distress BRA Bersuch

8

Gefahrstoff Detector Array 2(GDA2)

Detection and Monitoring of Gases and CWA

ETW-List

(Einsatztoleranzwert)

CWA-List

(Chemical Warfare Agents)

Page 9: A T F Analytical Task Force for Chemical Distress BRA Bersuch

9

Gaschromatograph-Massenspektrometer (GC-MS)

Gas chromatograph with Mass Spectrometer coupling

Analyse of volatile Substances in:

–Air–Water –Soil

Page 10: A T F Analytical Task Force for Chemical Distress BRA Bersuch

10

Aufbau des GC-MS

GCMSGCMS: Bauteile

Electrical Power

Computer

MS Mass Spectrometer

Electronic-Module

Gas- Supply- module

GC Gas-ChromatographParts

TUHH

Page 11: A T F Analytical Task Force for Chemical Distress BRA Bersuch

11

Analytische Bandbreite des GC-MS

» Organic Chemicals» Industrial Chemicals» ETW-Substances» Pesticides» Smoke analytic» Forge water analytic.» Drug detection» Explosives» CWA

More than 180.000 Substances and mixtures from the area of the organic Chemistry

(VOC).

Page 12: A T F Analytical Task Force for Chemical Distress BRA Bersuch

12

Fourier-Infrarotspektrometrie (FTIR)

SIGIS II (Scanning Infrared Gas-Measurement Imaging System II)

Passive Infrared Spectrometer

• Long distance detection of Hazardous goods (clouds) less than 5 km up to 17 Km (Etna), weather dependent

• Detection of all infrared active substances.

• Detection of abnormal air phenomena

Page 13: A T F Analytical Task Force for Chemical Distress BRA Bersuch

13

Fourier-Infrarotspektrometrie FTIR

Teleskop

GPS

Scanner-spiegel

Interferometer

Drehbarer Kopf

TUHH

Page 14: A T F Analytical Task Force for Chemical Distress BRA Bersuch

14

Fourier-Infrarotspektrometrie FTIR

Identification of Ammonia

TUHH

Page 15: A T F Analytical Task Force for Chemical Distress BRA Bersuch

15

HazMat ID

Active Infrared Spectrometer

HazMat ID (Hazardous Materials Identification)

Identification of:

» Solid substances» Liquid substances» Limited usable for Biological substances

Page 16: A T F Analytical Task Force for Chemical Distress BRA Bersuch

16

HazMat ID

Display

Page 17: A T F Analytical Task Force for Chemical Distress BRA Bersuch

17

Alarming and Request ATF

• Decision on the spot

• GEL > GMLZ > ATF

• Evaluation by the ATF

• If necessary request for assistance !

Page 18: A T F Analytical Task Force for Chemical Distress BRA Bersuch

18

1. Advice by telephone.

2. Consulter to the Spot.

3. Whole ATF to the spot.

3.1 Autarchy.

3.2 Transport to the spot.

3.3 leading structure on the spot.

Page 19: A T F Analytical Task Force for Chemical Distress BRA Bersuch

19

Einsätze der ATF in 2006-2007

1. Rhadereistedt

- 4 Tote in Biogasanlage nach Austritt von H2S

- Humanfreimessungen für das

Gerichtsmedizinische Institut

2. WM 2006 in Deutschland

- Monitoring der Stadien und der Versammlungs- stätten an Großveranstaltungsorten

- ABC-Abwehrkonzept

3. Strahlsund

- Monitoring beim Besuch des Amerikanischen Präsidenten

Page 20: A T F Analytical Task Force for Chemical Distress BRA Bersuch

20

Einsätze der ATF in 2006-2007

4. Teilnahme der ATF an der Europäischen Übung EUDAN EX

- Übung eines Bahnunglücks im Tunnel mit Austritt von gefährlichen Chemikalien

- Analyse an einer schmutzigen Bombe mit

realen Kampfstoffen

5. Bahnunglück in Tornesch

- Monitoring des Areals

- Analysen mit Feldversuchen vor Ort

- Beratung des GEL und des Landkreises

6. ABC-Schule der Bundeswehr in Sonthofen

- Identifikation und Vermessung von CWA

Page 21: A T F Analytical Task Force for Chemical Distress BRA Bersuch

21

Einsätze der ATF in 2006-2007

7. ASEM-Gipfel in Hamburg

- Monitoring der Unterkunfts- und Tagungsstätten der Staatsgäste

8. G8-Gipfel in Heiligendamm

- Polizeiliche- und nichtpolizeiliche C-Abwehr

- Monitoring der Demonstrations- und

Eventstätten

- Feldanalytik im AB-SM (Kontrollpunkte)

- Probenvermessung mit GDA GCMS etc.

- Beratung des Kavalla-, des NipoG-Stabes und der Kräfte vor Ort

Page 22: A T F Analytical Task Force for Chemical Distress BRA Bersuch

22

Vielen Dank für Ihre Aufmerksamkeit!