a variety of internet services are provided globally with ...pamphlet-1_datasheet_en.pdf · note 3:...
TRANSCRIPT
Greater Integration with CX-One Version 2.1
Ver. 2.1CXONE-AL C-EV2/-AL D-EV2
FA Integrated Tool Package
CX-One
This catalog mainly provides information that is necessary for selecting suitable models, and does not contain precautions for correct use. Always read the precautions and other required information provided in product operation manuals before using the product.
The application examples provided in this catalog are for reference only. Check functions and safety of the equipment before use.Never use the products for any application requiring special safety requirements, such as nuclear energy control systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, or other application involving serious risk to life or property, without ensuring that the system as a whole has been designed to address the risks, and that the OMRON products are properly rated and installed for the intended use within the overall equipment or system.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Authorized Distributor:
Note: Specifications subject to change without notice. Cat. No. R134-E1-04
0907
Note: Do not use this document to operate the Unit.
OMRON Corporation Control Devices Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,Kyoto, 600-8530 JapanTel: (81)75-344-7109Fax: (81)75-344-7149
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD HoofddorpThe NetherlandsTel:(31)2356-81-300Fax:(31)2356-81-388
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,IL 60173-5302 U.S.A.Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),Alexandra Technopark, Singapore 119967Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road,Pu Dong New Area, Shanghai, 200120, ChinaTel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
A variety of Internet services are provided globally with the CX-One so that the customer's software environment will always be up-to-date. Services to users with a registered CX-One installation include automatic updates when an update is released and Internet downloads of function objects from the Function Block and Smart Active Parts libraries.
CX-One Web Server
Online user registrationDownloading Function Block and Smart Active Parts LibrariesCX-One auto-updates for minor version upgrades
A variety of Internet services are provided, such as automatic updates.
The product names and company names in this document are the registered trademarks or trademarks of the respective companies.
Smart Platform
2 3
Function Block library/Smart Active Parts Library/Component Profile Sheet
(TM)
OMRON's lineup of control devices and controllers includes a wide range or products from Sensors to Temperature Controllers, Programming Controllers, Motion Controllers, and Touch Panels. And to enable easily connecting, setting up, and programming these products to quickly achieve the desired FA system, OMRON provides Smart Libraries, a vital system that supports all of the CX-One Support Software. It's like a dream come true.
Settings can be made as if a seasoned worker with vast experience with control devices is right at your side.
Work time and engineer costs are greatly reduced.
Communications programming is built in, achieving "Plug and Work" capabilities.
Just select and paste to significantly improve work efficiency.
CX-One
Ver. 2.0
CX-One
Ver. 1.0
Greater Integration with the CX-OneThe Smart Libraries support the entire CX-One system.
The CX-One continues to evolve.
: MECHATROLINK is a registered trademark of the MECHATROLINKMembers Association.
With complete integrated simulation
and improved support for sequential
function charts, structured text, and
other IEC 61131-3 languages, CX-One
version 2.1 provides performance for
all stages of production, from
equipment design, programming, and
debugging through startup, operation,
and maintenance to help reduce the
customer's Total Cost of Ownership.
Progressing toward further development!
Engineer costs
for
work
Time required
Normal completion
Temperature Controller unit No. Set temperature
123Rotation speed
F B
Smart Active Parts
Activescreen
FB
DeviceNet
CompoWay/F
Controller Link
Ethernet
MECHATROLINK-II
CPS
The latest objects can be obtained at any time from the Web or a CD-ROM.
Function Blocks
Ver. 2.1
Ver.
Ver.
Ver.
2.0
1.1
1.0
CPS
System Design
Unit Configuration
Parameter Settings
Programming
Integrated Debugging
Operation and
Maintenance
Integrated simulation achieves online checking of ladder programming and touch panel controls. Function blocks can be created from user ladder programming and IEC 61131-3 structured text (ST) language can be used in function blocks.
The new CX-Designer HMI Design Software joins greatly reducing PLC programming and debugging work through features such as function block nesting and instance monitoring.
The CX-One was introduced under the concept of OMRON's Smart Platform device control system, which enables easy access to any device from anywhere.
A new system released by OMRON in July 2004 for integrated management of data for control devices and controllers used in production equipment.
Incorporate Smart Active Parts into your touch panel screens to reduce work for both designing and debugging screens while improving quality through standardization.
The Function Block Library is a library of functional programming objects for OMRON's CS/CJ-series PLCs. Incorporating function blocks into your PLC programming reduces work for developing programming while improving quality through standardization.
A Component Profile Sheet (CPS) holds ID data, parameter definitions, and Support Software data, including model numbers and unit versions of PLCs and components. Using the definition data held in the CPS reduces device setup work with Support Software. Also, introducing Component Profile Sheets enables keeping Support Software up to date.
Objects can be obtained from the CD-ROM supplied with the components or downloaded as desired from libraries on the Web. The objects can then be saved in individual custom libraries.
(See note.)
Integrated simulation can now be started from the CX-Programmer!
4 5
Integrated simulation can be started from either the CX-Programmer or the CX-Designer. This enables more easily performing integrated simulation and debugging.
Now, system errors can be easily checked using only a computer!
Operation of monitoring programming when errors occur can be verified on a computer. Saving operations in CSV files when errors occur simplifies making test reports.
Now, variable data can be easily copied from the CX-Designer to the CX-Programmer.
Variable data can be easily shared. No work is required to manage data allocations. Comments can also be copied.
Integrated Simulation for Greater Design and Deb ugging Efficiency
Even Easier Integrated Simulations!
Greatly Improved Design Efficiency! The CX-One is even easier to use through the addition of functions from CX-One version 2.0, such as starting simulation from the CX-Programmer and customizing test screens.
A New PLC Error Simulator Enables Easily Checking
Operation of Debugged Programs When System Errors Occur!The coverage of integrated simulation has been further expanded by enabling generation of PLC system errors on the computer, thus eliminating the need to use actual equipment. This allows the user, for example, to easily debug programming that handles system errors.
Variable data can be easily shared between
the CX-Programmer and CX-Designer!The ability to easily copy and paste CX-Designer variable data to the CX-Programmer further improves the efficiency of integrated simulation. For example, variables that have been changed due to revisions in touch panel screens can be easily updated in the CX-Programmer.
1
2
3
Position OK!
Starting from the CX-Programmer Starting from the CX-Designer
Starting Integrated Simulation PLC Error Simulator
Sharing Variable Data
Version Upgrade
Version Upgrade
Integrated Simulation between PLCs and Touch Panels
1 Start integrated simulation with
the press of a button.
1 Start integrated simulation with
the press of a button.
2 Select the CX-Designer file.
2 Select the CX-Programmer file.
3 Click the Start Button.
3 Click the Start Button.
During simulation, it is possible to change the touch panel display position, pin the screen display on top, and specify the size.
Variable names
Addresses
Comments
Variable names
Addresses
Comments
New adjustment functions enablecustomizing the debugging environment!
The size of the PT screen can be changed.
The PT screens can be kept displayed in front.
The PT screen position can be saved.
Startup has been completed!
NEW
NEW!
CX-Programmer Support Software for PLCs
CX-Designer Screen Designing Software for NS-series PT Touch Panels
Integrated simulation could be started only from the CX-Designer, even thoughstarting from the CX-Programmer would sometimes be more convenient. There was also the need to customize screen positioning and other factors in the debugging environment, and to keep the PT screens displayed in front.
Previously, error-handling programming was verified by generating errors using error-generation commands in a program running on the PLC. Preparation and execution required too much time.
Previously, it was possible to copy and paste from the CX-Programmer to the CX-Designer, but not in the opposite direction. It was a lot of trouble to bring variable data created in the CX-Designer to the CX-Programmer.
CX-Programmer Support Software for PLCs
CX-Designer Screen Designing Software for NS-series PT Touch Panels
Starting was not possible.
Starting was possible.
ST
Ladder programming
Variables
6 7
NEW! NEW!
NEW!
NEW!
Note: The PLC connected to the computer must be a CS/CJ-series PLC with unit version 4.0 or later.
A wider variety of programming languages is being used along with the greater diversity of PLC applications. With the CX-Programmer (CX-One), support for sequential function charts (SFC) improves program readability. (See note.)
Compare function block (FB) definitions in detail to
easily manage changes.
Program Conversion from C500/C120/C P.
Easily Handle Demands for Equipment Changes!
Sequential Function Charts Function Block Comparison
Using structured text (ST) programming in tasks amazingly
simplifies numerical processing. (See note.)
Structured Text
Enhanced program comparison enables detailed comparison of function blocks and structured text!
Easily Replace Your PLCs with CP1L/H, CJ1, or CS1 PLCs
Sequential function charts (SFC) is a language used to express the flow of process steps as graphical charts that combine steps and transitions. SFC complies with the IEC 61131-3 standard. Structured text (ST) is a high-level language for industrial control that allows programming numerical processing and repetition processing more simply than ladder diagrams. ST complies with the IEC 61131-1 standard.
Support for sequential function charts and structured text provides for a variety ofprogramming language environments.
Supported
for unit version
4.0 or later.
Support is provided with CS/CJ-series PLCs with unit version 4.0 or later. To acquire a CS/CJ-series PLC with unit version 4.0, contact your OMRON representative.
It takes almost 30 minutes to
program using ladder
diagrams!
Program averaging of 200 points in only nine lines. Written in five
minutes!
Present values can be monitored and
changed. (All work times are reference values.)
FB FBFB_MC1_P1 FB_MC1_P1
The flow of process step programming is difficult to understand with ladder programming. Plus, interlocks and jumps are required.
Until now, it has not been possible to see the results of detailed comparison of ladder programming in function block (FB) definitions. This made it difficult to manage changes in function blocks.
Using ladder programming to write numerical processing is complicated. The number of inputs increases and it takes a lot of time to write averages or values for hundreds of measurement values.
Using SFC enables understanding the line structure and the process flow at a glance!
Programming can be made that follows the process flow. The processes that are being executed can be understood at a glance, which simplifies monitoring process status. Programming each process separately helps to achieve structured programs and makes programming easier to reuse.
Detailed comparison of function block definitions can be performedfrom CX-Programmer version 7.2.
Ladder programming, ST, and changes in variables in FB definitionscan be checked in detail.
Temporarily backing up C500/C120/C P-series programs to a computer, such as is required when replacing Units, was possible only when the PLC was online with the computer. Working online was not possible when converted to other models. With C500/C120/C P-series PLCs, only the programs could be backed up, but not data from the DM or HR Areas.
Files backed up on a computer from C500/C120/C P-series PLCs can be converted to projects for the CP1L/M, CJ1, CS1, or CVM1. Of course, work can be performed online. With C500/C120/C P-series PLCs, only the programs could be backed up, but the backup function has been expanded to now include programs, DM Area data, and HR Area data. CX-One version 2.1 can be used to change models to the CP1L, which is ideal for updating small machinery and equipment.
Using ST, writing a program to average hundreds of points requires only a few lines!
The ability to write repetition processing and judgment processing in only a few lines greatly shortens the time required for programming. Text string data is can be used. Measured thickness data or other text string data can be easily analyzed.
DesignedJune 12
DesignedJune 15
Note: The PLC connected to the computer must be a CS/CJ-series PLC with unit version 4.0 or later.
Supported
for unit version
4.0 or later.
Support is provided with CS/CJ-series PLCs with unit version 4.0 or later. To acquire a CS/CJ-series PLC with unit version 4.0, contact your OMRON representative.
There seem to be some
changes, but what was changed?
FailureTransfer
Time
Retransfer
CompletedTransfer time onsite
8 9
Transfer to computer from a DeviceNet network can be resumed!
The maximum number of Controller Link data link send words per node has been increased from 1,000 to 4,000!
Easier Adjustment for Temperature and Process Control!
If communications fail when uploading DeviceNet network data (slave data) using the CX-Integrator, uploading can be resumed from the point where failure occurred, thereby greatly shortening the time for transferring network data to the computer.
Support is provided for Controller Link Units (soon to be released), which have increased the maximum number of send/receive words per Unit fourfold from the previous 1,000 words to 4,000 words when data links are used (see note). This can be used to increase the amount of data shared between PLCs, such as for exchanging data on quality. Note: CS1W-CLK13/23/53, CJ1W-CLK23, and 3G8F7-CLK13/23/53.
Version 3.2 of the CX-Thermo
Now, settings of parameters being monitored in the Trend View Window can be changed.
Easier Memory Allocation for the EJ1 and PLCs Now, parameter selections and memory allocations for programless communications of the EJ1 and PLCs can be set in a table while viewing the PLC memory address.
Ethernet
Routing tables can be transferred from one location to multiple PLCs!Routing tables can be set and transferred from one PLC to other PLCs on a network without reconnecting cables. (See note.)
Transferring routing tables is easy using a direct Ethernet connection! Routing tables can be transferred from a computer to a PLC connected with an Ethernet cable.
Transferring Routing Tables to Networks
Direct Ethernet Connections
Version Upgrade The Popular Automatic Online Connection to PLCs Is Now Even Easier!
The computer's serial ports are automatically searched when an automatic online connection is used, so it is no longer necessary to individually specify the port used.
Automatic Search for Computer Port for Automatic Online Connection
Version Upgrade
Version Upgrade
Version Upgrade
Setting and transferring routing tables required a lot of time onsite to reconnect the cables for each PLC.
Routing tables can be set and transferred from a PLC in just one location!Work is greatly simplified by the ability to set and transfer routing tables from one location to all the PLCs on a network of the same layer.
The computer port (e.g., COM2 or COM3) had to be specified using a separate menu command for selecting the connection port when an automatic online connection was performed with the PLC connected to the computer's USB port (except for COM1).
No communications port settings are required! Only the connectable communications ports are displayed, so online connection is easy. Online connection can be easily made with two clicks of the mouse. There's no need to worry whether online connection at the worksite will be possible when an error occurs.
Routing tables can be transferred with the PLCs connected to an Ethernet network. Routing tables can be transferred from the computer to a PLC using an Ethernet cable. No work is required for reconnecting Peripheral Cables onsite.
A separate Peripheral Cable was required to transfer routing tables when the computer and the PLC were directly connected using Ethernet. Work for making routing table settings onsite was troublesome.
Network
Serial connection
Note: Routing tables cannot be set across network layers (same as previously). The PLC connected to the computer must be a CS/CJ-series PLC with unit version 4.0 or later.
Supported
for unit version
4.0 or later.
Support is provided with CS/CJ-series PLCs with unit version 4.0 or later. To acquire a CS/CJ-series PLC with unit version 4.0, contact your OMRON representative.
Work is easy!
Easy online connection with two clicks!
No Peripheral Cable required!
of the port used on the computer
Much shorter!
Even Less Time Required to Design Networks
Resuming transfer to computer No
Start
Resuming transfer to computer Yes
Make numeral displays and input objects more attractive, and increase or decrease the character string font size as desired.
There is no need to create similar error screens, so you can easily create a device troubleshooter.
Troubleshooting Easily Supported with Multi-language Functionality
Greatly Enhanced Libraries of Beautiful Lamps and Switches
10 11
Use an attractive font for numerals that looks good on the display even when it is enlarged. Seven-segment fonts are also available. And, smooth fonts can be used for alarms and character strings, and scalable fonts can be selected. In addition, worldwide support is provided with 42 languages, including Thai.
New 7-segment font
Thai
Alarm display with new scalable Gothic font
New numeral font
A selection of over 800 beautiful objects is provided. Now, it's easier to allocate and change objects.
Individual error display screens that were previously created for each error can now be integrated into one. It is possible to switch only the error details (text and screen) without ladder programming in conjunction with the alarm bit
Multi-language machine troubleshooting can be easily achieved by saving the Englishscreen data in an Excel file, having it translated, and then importing the results.
CX-One version 2.1 newly supports Windows Vista, the latest edition of the Microsoft OS. CX-One can now be used on the latest computer OS. Version 2.1 also support Korean Windows. Transitioning and training onsite will be easier in any application environment, even with the expected expansion of tasks abroad. With CX-One version 2.1, Korean display is possible for tool menus and comments in the CX-Programmer, as well as for the installation windows.
With this system, the frames are shared, and the error details in the pink frames are switched with an alarm or other item as the trigger.
Text selection Screen selection
Support for the Latest Windows OS Vista Further Expansion of Applications Environments with Support for Korean
Ver. 2.1
Upgrade planned for the near future
Greater Beauty
Easier Design of Device Error Screens
Greater Beauty, Simpler,
and Better Multi-language Support
For example, in conjunction with an alarm bit (See note.)
Alarm bit 10.01 ON (no paper)
Alarm bit 10.02 ON (printing error)
Note: Alarms, PLC/PT memory, and other items can be selected for the switching trigger.
The following table shows the Support Software (Configuration Tools) installed by the CX-One Version 2.1.
FA Integrated ToolPackage CX-OneVersion 2.1
FA Integrated ToolPackage CX-OneLite Version 2.1
Name Compatible OS DescriptionMedia(See note 2.) Model
Number of licenses(See note 1.)
Computer
Memory (See notes 2.)
Hard disk
Display
Disk drive
Communications ports
Other
IBM PC/AT or compatible with a processor recommended by Microsoft.
CX-ProgrammerVer. 7.2
(Upgrade planned
CX-IntegratorVer. 2.1
CX-ProtocolVer. 1.7
CX-SimulatorVer. 1.8
CX-PositionVer. 2.4
CX-Motion-NCFVer. 1.5
Operating system (OS)(See notes 1.) Microsoft Windows98 SE
Microsoft Windows NT(Service Pack 6a)
Microsoft Windows Vista (except 64-bit edition) (See note 4.)
Microsoft Windows 2000(Service Pack 3 or higher) orMicrosoft Windows Me
Microsoft Windows XP
512 MB minimum, 1 GB recommended.
Item
OutlineSupport Softwarein CX-One OutlineSupport Software
in CX-One
Requirement
Approx. 2.2 GB or more available space is required to install the complete CX-One package.
SVGA (800 x 600) or better high-resolution display with 256 colors min. XGA or better display is required for the CX-Process Software.
CD-ROM drive or DVD drive
One RS-232C port min. (See note 3.)
Internet access is required to use online user registration, including a modem or other hardware connection method.
256 MB minimum, 512 MB recommended.
IBM PC/AT or compatible with a Pentium II 333 MHz or faster processor (Pentium III 1 GHz or faster recommended.)
SwitchBox UtilityVer. 1.6
CX-MotionVer. 2.3
CX-DriveVer. 1.4
CX-Process ToolVer. 5.1
Faceplate Auto-Builder for NSVer. 3.0
CX-Thermo Ver. 3.2 (See note 3.)
CX-FLnetVer. 1.0
CX-Motion-MCHVer. 2.1
CXONE-AL50D-EV2
CXONE-LT01C-EV2
CXONE-AL50C-EV2
CXONE-AL30D-EV2
CXONE-AL30C-EV2
CXONE-AL10D-EV2
CXONE-AL10C-EV2
CXONE-AL03D-EV2
CXONE-AL03C-EV2
CXONE-AL01D-EV2
CXONE-AL01C-EV21 license
3 licenses
10 licenses
30 licenses
50 licenses
1 license
CD
DVD
CD
DVD
CD
DVD
CD
DVD
CD
CD
DVD
Ordering Information
System Requirements
Support Software Contained in the CX-One Version 2.1
Windows 98 SE, Me, NT 4.0(Service Pack 6a), 2000(Service Pack 3 or higher), XP,or VistaNote
supported.
downloaded and updatedfrom the Microsoft Download center of eachregion.
CX-One is a comprehensive software packagethat integrates Support Software for OMRONPLCs and components.
CX-One Lite is a subset (see note 3) of the completeCX-One package that provides only the SupportSoftware required for micro PLC applications. It canbe used only with micro PLCs. (See note 4.)
Note 1: Site licenses are available for users who will run CX-One on multiple computers. Ask your OMRON sales representative for details.Note 2: When purchasing the DVD format, verify the computer model and DVD drive specifications before purchasing.Note 3: CX-One Lite provides the following Support Software: CX-Programmer Ver. 7.2 (micro PLCs only), CX-Integrator Ver. 2.1, CX-Simulator Ver. 1.8, CX-Designer Ver. 2.1, CX-Protocol Ver. 1.7,
Note 4: The following micro PLCs are supported by CX-One Lite: CP1@, CPM@@, and SRM1.
Note 1: If the complete CX-One package is installed, approximately 1.9 GB of hard disk space will be required.
3: Installation and operation are supported only for Microsoft Windows 2000 (Service Pack 3 or higher) and XP.
CX-One OS Precaution: The CX-One will not run on Microsoft Windows 95 or any other OS notlisted above. If such an OS is being used on the client computer, the OS must be upgraded beforeinstalling the CX-One. System requirements and hard disk space may vary with the system environment.The amount of memory required varies with the Support Software applications used in CX-One. Refer to user documentation for individual Support Software for details.
Note 1:
Note 2:
An RS-232C port is required to connect the Support Software applications in CX-One to a PLC. If the computer provides only a USB port, use a CS1W-CIF31 USB/RS-232C Conversion Cable. To connect to a CP-series/NSJ-series PLC, however, an over-the-counter USB cable (type A-B) can be used to connected to the built-in USB port on the CP-series/NSJ-series PLC.The following restriction apply when using CX-One version 2.1 with Windows Vista.• Some help files require downloading tool software provided by Microsoft. When connected to the Internet, a page for downloading will be displayed if a help file that requires support software is opened. (http://support.microsoft.com/kb/917607/en)• Restrictions apply to operation of some applications. Refer to the Setup Manual for details.
Note 3:
Note 4:
Application software to create and debug programs for SYSMACCS/CJ/CP/NSJ-series, C-series, and CVM1/CV-series CPU Units.
Application software to simulate SYSMAC CS/CJ/CP/NSJ-seriesCPU Unit operation on the computer to debug PLC programswithout a CPU Unit.
Application software to create and monitor data for SYSMACCS/CJ-series Position Control Units.
Application software to monitor and set parameters for SYSMACCS/CJ-series Position Control Units that support MECHATROLINK-IIcommunications. (See note 2.)
Application software to create protocols (communications sequences)between SYSMAC CS/CJ/CP/NSJ-series or C200HX/HG/HE SerialCommunications Boards/Units/ Option Boards and general-purposeexternal devices.
Application software to create data and motion programming and perform monitoring for SYSMAC CS/CJ-series MCH Units thatsupport MECHATROLINK-II communications. (See note 2.)
Application software to create data for SYSMAC CS-series,C200HX/HG/HE, and CVM1/Cvseries Motion Control Units, and tocreate and monitor motion control programs.
Application software to create and debug function block programsfor SYSMAC CS/CJ-series Loop Controllers (Loop ControlUnits/Boards, Process Control CPU Units, and Loop Control CPU
Application software that automatically outputs screen data asproject files for NS-series PTs from tag information in functionblock programs created with the CX-Process Tool.
Application software to set and control parameters in components,such as Temperature Control Units.
Application software for system setting and monitoring of SYSMAC CS/CJ-series FL-net Units.
Utility software that helps debug PLCs. It helps to monitor the I/Ostatus and to monitor/change specified present values within a PLC.
CX-ProfibusVer. 1.1
Software to configure a PROFIBUS Master.
Application software to set and control data for Inverters andApplication software to create screen data for the NS-series PTTouch Panels.
Application software to build and set up FA networks, such asController Link, DeviceNet, CompoWay/F, and Ethernet. The RoutingTable Component and Data Link Component can be started from thissoftware. DeviceNet Configuration functionality is also included.