a1 · a1.01 lower level record plan scale: 1/4” = 1’-0 ... studio finished ceiling = 78.5”...

2
A1.01 LOWER LEVEL RECORD PLAN SCALE: 1/4” = 1’-0” LOWER LEVEL PROPOSED SPACE PLAN SCALE: 1/4” = 1’-0” SYMBOL LEGEND WALL HEATER/A/C DUPLEX OUTLET QUADRUPLEX OUTLEY 240V OUTLET AREA CALCULATIONS: 1,089 SQ.FT. 546 SQ.FT. 401 SQ.FT. 185 SQ.FT. 2,222 SQ.FT. MAIN LEVEL H.L.A.: STUDIO (LOW CEILING): COVERED FRONT PORCH: BASEMENT STORAGE: TOTAL: NOTES: 1. FIELD VERIFY ALL DIMENSIONS - DIMENSIONS NOT SPECIFIED ARE ALIGNED WITH EXISTING STRUCTURE OR CENTERED IN A SPACE. 2. OUTLET, DATA JACK, LIGHT FIXTURES, PLUMBING FIXTURES AND HVAC VENT LOCATIONS ARE APPROXIMATE. A M.E.P. SURVEY WAS NOT CONDUCTED. FEILD VERIFY ALL LOCATIONS PRIOR TO INSTALLATIONS OR MODIFICATIONS. ALL OUTLETS ARE AT LEAST 42” AFF. 3. DUE TO THE HISTORIC NATURE OF THE MEASURED BUILDING, IRREGULARITIES IN ROOM SIZE AND SHAPE ARE COMMON - FIELD VERIFY AND ALLOW LARGER TOLERANCES FOR ALL HEAD HEIGHTS, BEARING HEIGHTS, AND CEILING SLOPES PRIOR TO ANY INSTALLATIONS. 4. DOORS AND WINDOWS WERE MEASURED TO FINISHED INTERIOR OPENING. 5. NEW INTERIOR PASSAGE DOORS TO BE 2’-8” X 6’-8”. CLOSET AND BATH DOORS TO BE 2’-2” X 6’-8”. STUDIO FINISHED CEILING = 78.5” AFF MECHANICAL COVERED PORCH COVERED DECK KITCHEN UP UP CONCRETE PATIO CONCRETE PATIO FINISHED CEILING = 78.5” AFF UNFINISHED CEILING = 80” AFF BOTTOM OF GIRDER TO T.O. SUBFLOOR = 106.5” AFF UNFINISHED CEILING = 106.5” AFF (TYP) BOTTOM OF BEAM TO T.O. SUBFLOOR = 86.5” AFF 19'-1 1/2" 15'-1/2" 22'-7" 10'-0" 8'-7" 4'-11" 9'-9" 4'-0" 22'-6 1/2" DROPPED BEAM STEEL GIRDER DROPPED BEAM 12'-3 1/2" 4 1/2" 5'-0" 6 1/2" 5'-0" 4 1/2" 8'-10" 3'-9 1/2" 2'-10" 10'-4 1/2" 6'-4" 2'-1/2" 4'-10" 7 1/2" 8'-8 1/2" NEW WALLS IN BLACK 4'-9 1/2" 1'-6" 2'-0" 2'-6" 2'-0" 3'-0" 5'-9" 2'-0" 3'-0" 2'-0" FLUSH EXITING WALL TO REMAIN NEW 6X4 WINDOW. EXPANDED OUT FROM CENTER LINE OF EXISTING WINDOW 1'-1 1/2" HVAC ABOVE 13'-9 1/2" 14'-3 1/2" 16'-4" C L 3'-0" 3'-0" C L 2X6 PLUMBING WALL 9'-4" TV TV TV W/D TALL CABINET FOR PANTRY 2'-0" 4'-3" 2'-0" 1'-6" ENCLOSE DOOR ENCLOSE EXISTING WALL SHELVES LIN CL CL ENCLSOE DOOR R&S R&S R&S UPPER CABINETS DW REF UP EXISTING DECK TO REMAIN EXISTING TO REMAIN EXISTING TO REMAIN EXISTING TO REMAIN Cocaris Real Estate Group, Inc. RESIDENTIAL MIXED USE REMODEL 927 GREENVILLE HWY HENDERSONVILLE, NC Asheville.Brevard.Cashiers. NC [email protected] 1.828.577.1915 Floor Plans 2020.07.28

Upload: others

Post on 02-Feb-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • A1.01

    LOWER LEVEL RECORD PLANSCALE: 1/4” = 1’-0”

    LOWER LEVEL PROPOSED SPACE PLANSCALE: 1/4” = 1’-0”

    SYMBOL LEGEND

    WALL HEATER/A/C

    DUPLEX OUTLET

    QUADRUPLEX OUTLEY

    240V OUTLET

    AREA CALCULATIONS:1,089 SQ.FT.

    546 SQ.FT.401 SQ.FT.185 SQ.FT.

    2,222 SQ.FT.

    MAIN LEVEL H.L.A.:STUDIO (LOW CEILING):COVERED FRONT PORCH:BASEMENT STORAGE:TOTAL:

    NOTES:1. FIELD VERIFY ALL DIMENSIONS - DIMENSIONS NOT SPECIFIED ARE ALIGNED WITH EXISTING STRUCTURE OR CENTERED IN A SPACE.2. OUTLET, DATA JACK, LIGHT FIXTURES, PLUMBING FIXTURES AND HVAC VENT LOCATIONS ARE APPROXIMATE. A M.E.P. SURVEY WAS NOT CONDUCTED. FEILD VERIFY ALL LOCATIONS PRIOR TO INSTALLATIONS OR MODIFICATIONS. ALL OUTLETS ARE AT LEAST 42” AFF.3. DUE TO THE HISTORIC NATURE OF THE MEASURED BUILDING, IRREGULARITIES IN ROOM SIZE AND SHAPE ARE COMMON - FIELD VERIFY AND ALLOW LARGER TOLERANCES FOR ALL HEAD HEIGHTS, BEARING HEIGHTS, AND CEILING SLOPES PRIOR TO ANY INSTALLATIONS.4. DOORS AND WINDOWS WERE MEASURED TO FINISHED INTERIOR OPENING.5. NEW INTERIOR PASSAGE DOORS TO BE 2’-8” X 6’-8”. CLOSET AND BATH DOORS TO BE 2’-2” X 6’-8”.

    STUDIO

    FINISHED CEILING= 78.5” AFF

    MECHANICAL

    COVEREDPORCH

    COVEREDDECK

    KITCHEN

    UP

    UP

    CONCRETE PATIO

    CONCRETE PATIO

    FINISHED CEILING= 78.5” AFF

    UNFINISHED CEILING= 80” AFF

    BOTTOM OF GIRDER TO T.O. SUBFLOOR

    = 106.5” AFF

    UNFINISHED CEILING= 106.5” AFF (TYP)

    BOTTOM OF BEAM TO T.O. SUBFLOOR

    = 86.5” AFF

    19'-1

    1/2

    "15

    '-1/2

    "

    22'-7"10'-0"

    8'-7"

    4'-1

    1"9'

    -9"

    4'-0" 22'-6 1/2"

    DROPPED BEAM

    STEEL GIRDER

    DROPPED BEAM

    12'-3 1/2" 4 1/2" 5'-0" 6 1/2" 5'-0" 4 1/2"

    8'-1

    0"3'

    -9 1

    /2"

    2'-1

    0"

    10'-4 1/2" 6'-4" 2'-1/2" 4'-10" 7 1/2"

    8'-8 1/2"

    NEW WALLS IN BLACK

    4'-9

    1/2

    "1'

    -6"

    2'-0

    "2'

    -6"

    2'-0

    "3'

    -0"

    5'-9

    "2'

    -0"

    3'-0

    "2'

    -0"

    FLUSH EXITING WALLTO REMAIN

    NEW 6X4 WINDOW.EXPANDED OUT FROMCENTER LINE OF EXISTINGWINDOW

    1'-1 1/2"

    HVAC ABOVE

    13'-9 1/2" 14'-3 1/2"

    16'-4

    "

    C L

    3'-0

    "3'

    -0"

    C L

    2X6 PLUMBING WALL

    9'-4"

    TV

    TV

    TV

    W/D

    TALL CABINETFOR PANTRY

    2'-0" 4'-3" 2'-0" 1'-6"

    ENCLOSE DOOR

    ENCLOSE EXISTING WALL

    SHELVES

    LINCLCL

    ENCLSOE DOOR

    R&S R&S

    R&S

    UPPER CABINETS

    DW

    REF

    UP

    EXISTING DECK TO REMAIN

    EXISTING TO REMAIN

    EXISTING TO REMAIN

    EXISTING TO REMAIN

    Coc

    aris

    Rea

    l Est

    ate

    Gro

    up, I

    nc.

    RESI

    DEN

    TIAL

    MIX

    ED U

    SE R

    EMO

    DEL

    927

    GRE

    ENVI

    LLE

    HW

    YH

    END

    ERSO

    NVI

    LLE,

    NC

    Asheville.Brevard.Cashiers. [email protected]

    1.828.577.1915

    Floor Plans

    2020

    .07.

    28

  • B.O. FINISHED BEAM= 165.5” AFF

    A1.01

    SYMBOL LEGEND

    WALL HEATER/A/C

    DUPLEX OUTLET

    QUADRUPLEX OUTLEY

    240V OUTLET

    AREA CALCULATIONS:745 SQ.FT.

    1,087 SQ.FT.1,832 SQ.FT.

    168 SQ.FT.400 SQ.FT.

    2,400 SQ.FT.

    MAIN LEVEL H.L.A.:UPPER LEVEL H.L.A.:TOTAL HEATED LIVING AREA:

    COVERED FRONT PORCH:COVERED BACK PORCH:TOTAL UNDER ROOF:

    NOTES:1. FIELD VERIFY ALL DIMENSIONS - DIMENSIONS NOT SPECIFIED ARE ALIGNED WITH EXISTING STRUCTURE OR CENTERED IN A SPACE.2. OUTLET, DATA JACK, LIGHT FIXTURES, PLUMBING FIXTURES AND HVAC VENT LOCATIONS ARE APPROXIMATE. A M.E.P. SURVEY WAS NOT CONDUCTED. FEILD VERIFY ALL LOCATIONS PRIOR TO INSTALLATIONS OR MODIFICATIONS. ALL OUTLETS ARE AT LEAST 42” AFF.3. DUE TO THE HISTORIC NATURE OF THE MEASURED BUILDING, IRREGULARITIES IN ROOM SIZE AND SHAPE ARE COMMON - FIELD VERIFY AND ALLOW LARGER TOLERANCES FOR ALL HEAD HEIGHTS, BEARING HEIGHTS, AND CEILING SLOPES PRIOR TO ANY INSTALLATIONS.4. DOORS AND WINDOWS WERE MEASURED TO FINISHED INTERIOR OPENING.5. NEW INTERIOR PASSAGE DOORS TO BE 2’-8” X 6’-8”. CLOSET AND BATH DOORS TO BE 2’-2” X 6’-8”.

    MAIN LEVEL PROPOSED PLANSCALE: 1/4” = 1’-0”

    MAIN LEVEL RECORD PLANSCALE: 1/4” = 1’-0”

    COVEREDPORCH

    FINISHED CEILING= 99.5” AFF

    COVEREDDECK

    OFFICERECEPTION

    FINISHED FLOOR= 0” AFF

    FINISHED CEILING @ WALL= 96” AFF

    FINISHED CEILING B.O. RIDGE BEAM= 148” AFF

    BREAK ROOMREST ROOM

    OPEN OFFICE

    CLOSET

    RAMP DN

    UP

    DN

    DN

    Coc

    aris

    Rea

    l Est

    ate

    Gro

    up, I

    nc.

    RESI

    DEN

    TIAL

    MIX

    ED U

    SE R

    EMO

    DEL

    927

    GRE

    ENVI

    LLE

    HW

    YH

    END

    ERSO

    NVI

    LLE,

    NC

    Asheville.Brevard.Cashiers. [email protected]

    1.828.577.1915

    Floor Plans

    2020

    .07.

    28