TRAVEL DISTANCE 29'-3" 8.9M TRAVEL DISTANCE 130'-5" 39.75M 227 228 236 238 235 237 239 239a 2S1 2C1 2C2 243 240 242 245 249 246 248 251 255 254 256 257 258 260 261 2S2 2C3 DOOR/FRAME/HARDWARE SCHEDULE ROOM DOOR FRAME NO. NAME TYPE THICKNESS HEIGHT WIDTH MATERIAL FINISH INSULATED FIRE RATING GLAZING MATERIAL FINISH THERMALLY BROKEN FIRE RATING WEATHERSTRIPPING DOOR CLOSER ALUMINUM THRESH. PASSAGE/PUSH PULL PRIVACY LOCKING EXIT HARDWARE KICK PLATE HARDWARE NOTES ROOM FINISH SCHEDULE NO. NAME VCT CARPET RUBBER BASE PAINT PAINT PAINT PAINT N E S W CEILING HEIGHT PAINTED CONCRETE GYPSUM ROOM FLOOR WALLS CEILING NOTES DOOR GROUP 1 227 STAFF 228 RECEPTION 231 WASHROOM 239a MECHANICAL GROUP A GROUP B GROUP C 227 STAFF 228 RECEPTION 2S1 STAIR LANDING 239a MECHANICAL 2C1 CORRIDOR 243 MECHANICAL 243b MOP CLOSET 231 WASHROOM 2C2 CORRIDOR 2C3 CORRIDOR 243 MECHANICAL 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 78" 78" 78" 84" 78" 84" 84" 78" 78" 78" WOOD WOOD WOOD WOOD WOOD H.M. WOOD WOOD WOOD 32" 32" 32" 36" 32" 36" 32" 32" 32" 32" PT PT PT PT PT PT PT PT PT PT WOOD WOOD WOOD WOOD WOOD H.M. H.M. WOOD WOOD WOOD 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 1 2 3 4 1 2 3 4 5 6 1 3 3 3 EXISTING DOOR & HARDWARE DOOR TYPE ELEVATIONS EXISTING DOUBLE DOOR & HARDWARE DOOR TYPE GROUPS GROUP 1 - DOORS : 235, 236, 237, 238, 239, 240, 242, 244, 245, 246, 247, 248, 249, 250, 251, 253, 257, 259, 260, 261 GROUP 2 - DOORS : 254, 255 GROUP 3 - DOORS : 256, 258 GROUP 4 - DOORS : 2C1, 2C2, 2C3 DOOR GROUP 2 DOOR GROUP 3 DOOR GROUP 4 254b CLOSET ROOM TYPE GROUPS GROUP A - ACADEMIC ROOMS : 242-44, 245-47, 248-50, 251-53, 257-59 GROUP B - SEMINAR ROOMS : 240, 243, 246, 249, 261 GROUP C - OFFICE ROOMS : 235, 236, 237, 238, 239 WASHROOM WASHROOM SHOWERS 254 255 256 256 PRAYER 260 OFFICE N.I.C. 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 4"x16" TILE WALL FINISH ON LOCATIONS NOTED ON A2.2 4"x16" TILE WALL FINISH ON LOCATIONS NOTED ON A2.2 PT PT PT PT PT PT PT PT PT PT PT PT EXISTING DOOR & HARDWARE w/ TRANSFER LOUVRE - RELOCATED 1 3/4" 78" 24" 9 WOOD WOOD WOOD 2S1 2S2 1 3/4" 84" WOOD 60" PT WOOD EXISTING DOOR & HARDWARE PT 1 3/4" 84" WOOD 36" PT WOOD PT STAIRWELL STAIRWELL 234 WASHROOM 1 3/4" 78" WOOD 24" PT WOOD PT EXISTING DOOR & HARDWARE w/ NEW 22"x30" GLAZING INSERT EXISTING DOOR & HARDWARE w/ TRANSFER LOUVRE EXISTING DOOR & HARDWARE EXISTING DOOR & HARDWARE 3' FULL HEIGHT SIDE LITE EXISTING DOOR & HARDWARE EXISTING DOOR & HARDWARE EXISTING DOOR & HARDWARE EXISTING DOOR & HARDWARE - RELOCATED 7 8 9 6'-6" 2'-8" 2'-6" 1'-10" 6'-6" 2'-8" 6'-6" 2'-8" 3'-0" 7'-0" 5 5'-0" 7'-0" 6 3'-0" 7'-0" 7 7'-0" 3'-0" 8 7'-0" 2'-8" 3'-0" 9 6'-6" 2'-4" 0'-4" 3'-0" 2'-0" 0'-8" 0'-8" 0'-8" PROJECT: DRAWING TITLE: DCSC PROJECT NO. OWNER PROJECT NO. REV. SCALE CHECKED BY: DRAWN BY: DATE: DRAWING NO. DCSC LIMITED ARCHITECT & ENGINEER THUNDER BAY ONTARIO NO. REVISIONS DATE As indicated LAKEHEAD UNIVERSITY PRETTE RESIDENCE ELP RENOVATION SECOND FLOOR O.B.C ANALYSIS, LIFE SAFETY $ SCHEDULES PR14-034 RLN DCB MAY 08 / 2015 A2.1 1/16" = 1'-0" 2 LIFE-SAFETY PLAN TRAVEL DISTANCE 35'-1" 10.7M D150101 0 ISSUED FOR TENDER MAY 08 2015

Upload: others

Post on 26-Mar-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire

TRAVEL DISTANCE 29'-3" 8.9M

TRAV

EL D

ISTAN

CE 1

30'-5

" 39.

75M

227

228236238

235237

239

239a

2S12C1

2C2

243

240

242

245

249

246

248

251

255

254

256

257258

260

261

2S2

2C3

DOOR/FRAME/HARDWARE SCHEDULEROOM DOOR FRAME

NO. NAME TYPE

THIC

KNES

S

HEIG

HT

WIDT

H

MATE

RIAL

FINIS

H

INSU

LATE

D

FIRE

RATIN

G

GLAZ

ING

MATE

RIAL

FINIS

H

THER

MALL

Y BRO

KEN

FIRE

RATIN

G

WEAT

HERS

TRIPP

ING

DOOR

CLO

SER

ALUM

INUM

THRE

SH.

PASS

AGE/P

USH

PULL

PRIV

ACY

LOCK

ING

EXIT

HARD

WARE

KICK

PLAT

E

HARDWARE NOTES

ROOM FINISH SCHEDULE

NO. NAME VCT

CARP

ET

RUBB

ER B

ASE

PAIN

T

PAIN

T

PAIN

T

PAIN

T

N E S W

CEILI

NG H

EIGHT

PAIN

TED

CONC

RETE

GYPS

UM

ROOM FLOOR WALLS CEILING NOTES

DOOR GROUP 1

227 STAFF228 RECEPTION231 WASHROOM

239a MECHANICAL

GROUP A

GROUP B

GROUP C

227 STAFF

228 RECEPTION

2S1 STAIR LANDING

239a MECHANICAL

2C1 CORRIDOR

243 MECHANICAL243b MOP CLOSET

231 WASHROOM

2C2 CORRIDOR

2C3 CORRIDOR

243 MECHANICAL

1 3/4"1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

78"78"

78"

84"

78"

84"

84"

78"

78"

78"

WOODWOOD

WOOD

WOOD

WOOD

H.M.

WOOD

WOOD

WOOD

32"32"

32"

36"

32"

36"

32"

32"

32"

32"

PTPT

PT

PT

PT

PT

PT

PT

PT

PT

WOODWOOD

WOOD

WOOD

WOOD

H.M.

H.M.

WOOD

WOOD

WOOD

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

1 2 3

4

12

3

4

5

6

1

3

3

3

EXISTING DOOR & HARDWARE

DOOR TYPE ELEVATIONS

EXISTING DOUBLE DOOR & HARDWARE

DOOR TYPE GROUPSGROUP 1 - DOORS :235, 236, 237, 238, 239, 240, 242, 244, 245,246, 247, 248, 249, 250, 251, 253, 257, 259,260, 261

GROUP 2 - DOORS :254, 255GROUP 3 - DOORS :256, 258GROUP 4 - DOORS :2C1, 2C2, 2C3

DOOR GROUP 2

DOOR GROUP 3

DOOR GROUP 4

254b CLOSET

ROOM TYPE GROUPSGROUP A - ACADEMIC ROOMS :242-44, 245-47, 248-50, 251-53, 257-59GROUP B - SEMINAR ROOMS :240, 243, 246, 249, 261GROUP C - OFFICE ROOMS :235, 236, 237, 238, 239

WASHROOM

WASHROOM

SHOWERS

254

255

256

256 PRAYER

260 OFFICE

N.I.C.

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

4"x16" TILE WALL FINISH ON LOCATIONS NOTED ON A2.2

4"x16" TILE WALL FINISH ON LOCATIONS NOTED ON A2.2

PTPT

PT

PT

PT

PT

PT

PT

PT

PT

PT PT

EXISTING DOOR & HARDWARE w/ TRANSFER LOUVRE - RELOCATED

1 3/4" 78" 24"

9

WOOD

WOOD

WOOD

2S1

2S21 3/4" 84" WOOD60" PT WOOD

EXISTING DOOR & HARDWARE

PT

1 3/4" 84" WOOD36" PT WOOD PT

STAIRWELL

STAIRWELL

234 WASHROOM 1 3/4" 78" WOOD24" PT WOOD PT

EXISTING DOOR & HARDWARE w/ NEW 22"x30" GLAZING INSERTEXISTING DOOR & HARDWARE w/ TRANSFER LOUVRE

EXISTING DOOR & HARDWARE

EXISTING DOOR & HARDWARE

3' FULL HEIGHT SIDE LITE

EXISTING DOOR & HARDWARE

EXISTING DOOR & HARDWARE

EXISTING DOOR & HARDWARE

EXISTING DOOR & HARDWARE - RELOCATED

7

8

9

6'-6"

2'-8"

2'-6"

1'-10" 6'-6"

2'-8"

6'-6"

2'-8"

3'-0"

7'-0"

5

5'-0"

7'-0"

6

3'-0"

7'-0"

7

7'-0"

3'-0"

8

7'-0"

2'-8"

3'-0"

9

6'-6"

2'-4"

0'-4"

3'-0"

2'-0" 0'-

8"0'-

8"0'-

8"

PROJECT:

DRAWING TITLE:

DCSC PROJECT NO. OWNER PROJECT NO. REV.

SCALE

CHECKED BY:

DRAWN BY:

DATE:

DRAWING NO.

DCSC LIMITED ARCHITECT & ENGINEERTHUNDER BAY ONTARIO

NO. REVISIONS DATE

As indicated

LAKEHEAD UNIVERSITYPRETTE RESIDENCE ELP RENOVATION

SECOND FLOORO.B.C ANALYSIS, LIFE SAFETY $ SCHEDULES

PR14-034

RLN

DCB

MAY 08 / 2015A2.1

1/16" = 1'-0"2 LIFE-SAFETY PLAN

TRAVEL DISTANCE 35'-1" 10.7M

D150101

0 ISSUED FOR TENDER MAY 08 2015

Page 2: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire

TRAVEL DISTANCE 29'-3" 8.9M

TRAV

EL D

ISTAN

CE 1

30'-5

" 39.

75M

227

228236238

235237

239

239a

2S12C1

2C2

243

240

242

245

249

246

248

251

255

254

256

257258

260

261

2S2

2C3

DOOR/FRAME/HARDWARE SCHEDULEROOM DOOR FRAME

NO. NAME TYPE

THIC

KNES

S

HEIG

HT

WIDT

H

MATE

RIAL

FINIS

H

INSU

LATE

D

FIRE

RATIN

G

GLAZ

ING

MATE

RIAL

FINIS

H

THER

MALL

Y BRO

KEN

FIRE

RATIN

G

WEAT

HERS

TRIPP

ING

DOOR

CLO

SER

ALUM

INUM

THRE

SH.

PASS

AGE/P

USH

PULL

PRIV

ACY

LOCK

ING

EXIT

HARD

WARE

KICK

PLAT

E

HARDWARE NOTES

ROOM FINISH SCHEDULE

NO. NAME VCT

CARP

ET

RUBB

ER B

ASE

PAIN

T

PAIN

T

PAIN

T

PAIN

T

N E S W

CEILI

NG H

EIGHT

PAIN

TED

CONC

RETE

GYPS

UM

ROOM FLOOR WALLS CEILING NOTES

DOOR GROUP 1

227 STAFF228 RECEPTION231 WASHROOM

239a MECHANICAL

GROUP A

GROUP B

GROUP C

227 STAFF

228 RECEPTION

2S1 STAIR LANDING

239a MECHANICAL

2C1 CORRIDOR

243 MECHANICAL243b MOP CLOSET

231 WASHROOM

2C2 CORRIDOR

2C3 CORRIDOR

243 MECHANICAL

1 3/4"1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

78"78"

78"

84"

78"

84"

84"

78"

78"

78"

WOODWOOD

WOOD

WOOD

WOOD

H.M.

WOOD

WOOD

WOOD

32"32"

32"

36"

32"

36"

32"

32"

32"

32"

PTPT

PT

PT

PT

PT

PT

PT

PT

PT

WOODWOOD

WOOD

WOOD

WOOD

H.M.

H.M.

WOOD

WOOD

WOOD

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

1 2 3

4

12

3

4

5

6

1

3

3

3

EXISTING DOOR & HARDWARE

DOOR TYPE ELEVATIONS

EXISTING DOUBLE DOOR & HARDWARE

DOOR TYPE GROUPSGROUP 1 - DOORS :235, 236, 237, 238, 239, 240, 242, 244, 245,246, 247, 248, 249, 250, 251, 253, 257, 259,260, 261

GROUP 2 - DOORS :254, 255GROUP 3 - DOORS :256, 258GROUP 4 - DOORS :2C1, 2C2, 2C3

DOOR GROUP 2

DOOR GROUP 3

DOOR GROUP 4

254b CLOSET

ROOM TYPE GROUPSGROUP A - ACADEMIC ROOMS :242-44, 245-47, 248-50, 251-53, 257-59GROUP B - SEMINAR ROOMS :240, 243, 246, 249, 261GROUP C - OFFICE ROOMS :235, 236, 237, 238, 239

WASHROOM

WASHROOM

SHOWERS

254

255

256

256 PRAYER

260 OFFICE

N.I.C.

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

8'-0"

4"x16" TILE WALL FINISH ON LOCATIONS NOTED ON A2.2

4"x16" TILE WALL FINISH ON LOCATIONS NOTED ON A2.2

PTPT

PT

PT

PT

PT

PT

PT

PT

PT

PT PT

EXISTING DOOR & HARDWARE w/ TRANSFER LOUVRE - RELOCATED

1 3/4" 78" 24"

9

WOOD

WOOD

WOOD

2S1

2S21 3/4" 84" WOOD60" PT WOOD

EXISTING DOOR & HARDWARE

PT

1 3/4" 84" WOOD36" PT WOOD PT

STAIRWELL

STAIRWELL

234 WASHROOM 1 3/4" 78" WOOD24" PT WOOD PT

EXISTING DOOR & HARDWARE w/ NEW 22"x30" GLAZING INSERTEXISTING DOOR & HARDWARE w/ TRANSFER LOUVRE

EXISTING DOOR & HARDWARE

EXISTING DOOR & HARDWARE

3' FULL HEIGHT SIDE LITE

EXISTING DOOR & HARDWARE

EXISTING DOOR & HARDWARE

EXISTING DOOR & HARDWARE

EXISTING DOOR & HARDWARE - RELOCATED

7

8

9

6'-6"

2'-8"

2'-6"

1'-10" 6'-6"

2'-8"

6'-6"

2'-8"

3'-0"

7'-0"

5

5'-0"

7'-0"

6

3'-0"

7'-0"

7

7'-0"

3'-0"

8

7'-0"

2'-8"

3'-0"

9

6'-6"

2'-4"

0'-4"

3'-0"

2'-0" 0'-

8"0'-

8"0'-

8"

PROJECT:

DRAWING TITLE:

DCSC PROJECT NO. OWNER PROJECT NO. REV.

SCALE

CHECKED BY:

DRAWN BY:

DATE:

DRAWING NO.

DCSC LIMITED ARCHITECT & ENGINEERTHUNDER BAY ONTARIO

NO. REVISIONS DATE

As indicated

LAKEHEAD UNIVERSITYPRETTE RESIDENCE ELP RENOVATION

SECOND FLOORO.B.C ANALYSIS, LIFE SAFETY $ SCHEDULES

PR14-034

RLN

DCB

MAY 08 / 2015A2.1

1/16" = 1'-0"2 LIFE-SAFETY PLAN

TRAVEL DISTANCE 35'-1" 10.7M

D150101

0 ISSUED FOR TENDER MAY 08 2015

Page 3: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire

UP

SEMINAR

240

ACADEMIC

242-44

SERVICE

243

SEMINAR

246

ACADEMIC

245-47

ACADEMIC

248-50

SEMINAR

249ACADEMIC

251-53

M. WASHROOM

254

W. WASHROOM

255ACADEMIC

257-59

SHOWERS

256

PRAYER

258

SEMINAR

261

OFFICE

260

3A2.3

2W2

2W4

2W22W22W2

2W2

2W2

2W2

2W1

2W2

2W2

2W2

2W2

D240

D243D245D247D249D251D253D255D257D259D261

D260

D2C2

D258 D2SH

D254b

D254D250 D248 D246 D244 D242

D2C1CORRIDOR

2C3STAIR LANDING

2S2

D243b

3'-6"

3'-6"

RECESSED FIREEXTINGUISHER CABINET

RECESSED FIREEXTINGUISHER CABINET

2'-0"

2'-0"

2-W3

2-W3

2W4132'-5"5'-

0"

15'-4"

6'-6"

7A2.3

N.I.C.

AREA OFWORK

SEMINAR

246

A2.4

18

17

16

19

2W2

D246

12'-8

"

15'-4"

WHITEBOARD TYPE 1249 SIM.

SIM.

SIM.

260

261

WHITEBOARD TYPE 2(LOCATION TO BE VERIFIED)

NEW VCTFLOORING

ACADEMIC

242-44A2.4

4

57

6

WHITEBOARD TYPE 1

2W2

245-47

248-50

SIM.

SIM.

SIM.

SIM.

251-53

257-59

WHITEBOARD TYPE 2(LOCATION TO BE VERIFIED)

NEW VCTFLOORING

17'-4

"

23'-4"

BULKHEAD ABOVE(SEE STRUCT DWG.)

SEMINAR

240A2.4

8

911

10

2W2

D240

12'-8

"

15'-4"

WHITEBOARD TYPE 1

WHITEBOARD TYPE 2(LOCATION TO BE VERIFIED)

NEW VCTFLOORING

2W2

BUILD TO FIT NEW ENCLOSUREAROUND EXISTING PIPING.

VERIFY DIMENSIONS ON SITE.

1'-2"

1'-8"

SERVICE

243

A2.4 15

14

13

12

2W4

D243

D243b

12'-8

"

15'-4"

4'-0"

7'-2"7'-8"

2'-6"

7'-8"

2'-8"

5'-2"

N.I.C.

SEE ELECTRICAL DWG. FOR NEW FIXTURES & LIGHTING

2-W2

WALL TYPE LEGEND

2-W1

INTERIOR - NEW AIR RETURN CHASE

5/8" TYPE 'X' GYPSUM WALL BOARD250S162-43 STEEL STUDS @ 16" O/C

INTERIOR PARTITION - NEW 3 1/2"

5/8" TYPE 'X' GYPSUM WALL BOARD350S162-43 STEEL STUDS @ 16" O/C3 1/2" ABSORPTIVE MATERIAL5/8" TYPE 'X' GYPSUM WALL BOARD

2-W3 INTERIOR - NEW PLUMBING CHASE

5/8" TYPE 'X' GYPSUM WALL BOARD350S162-43 STEEL STUDS @ 16" O/C

2-W4 INTERIOR - NEW 6" INFILL WALL

5/8" TYPE 'X' GYPSUM WALL BOARD600S162-43 STEEL STUDS @ 16" O/C6" ABSORPTIVE MATERIAL5/8" TYPE 'X' GYPSUM WALL BOARD

7'-2

1/2"

3'-4"0'-2

1/2"

0'-6"

6'-8"

0'-4

1/2"

5/8" TYPE 'X' GYPSUM WALL BOARD

350S162-43 STEEL STUDS

ELECTRICAL CONDUIT

SHEET METAL

8" x16" VENT(SEE MECH.)

8" x16" VENT(SEE MECH.)

6" x22" INSULATEDDUCT (SEE MECH.)

2W2

EXISTING BLOCKWALL

1'-4"

6'-0"

0'-8"

PROJECT:

DRAWING TITLE:

DCSC PROJECT NO. OWNER PROJECT NO. REV.

SCALE

CHECKED BY:

DRAWN BY:

DATE:

DRAWING NO.

DCSC LIMITED ARCHITECT & ENGINEERTHUNDER BAY ONTARIO

NO. REVISIONS DATE

As indicated

LAKEHEAD UNIVERSITYPRETTE RESIDENCE ELP RENOVATION

SECOND FLOOR ACADEMICPLAN, ENLARGED PLANS, SECTION DETAILS

PR14-034

RLN

DCB

MAY 08 / 2015A2.3

1/8" = 1'-0"1 SECOND FLOOR PLAN - ACADEMIC

1" = 100'-0"9 KEY PLAN - SECOND FLOOR

1/4" = 1'-0"4 ENLARGED PLAN - SEMINAR ROOM A

1/4" = 1'-0"5 ELNLARGED PLAN - ACADEMIC ROOM

1/4" = 1'-0"6 ENLARGED PLAN - SEMINAR ROOM B

1/4" = 1'-0"8 ENLARGED PLAN - SERVICE ROOM

1/8" = 1'-0"2 REFLECTED CEILING PLAN - ACADEMIC

1/2" = 1'-0"3 SECTION @ HALLWAY

1/2" = 1'-0"A2.37 AIR RETURN CHASE SECTION

D150101

0 ISSUED FOR TENDER MAY 08 2015

Page 4: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire

A2.52

1

4

3

2W1

11'-4" 3'-7 1/2"

7'-2"

5'-2"

M. WASHROOM

254

10'-1

0"

15'-4"

NEW TOILET PARTITIONSFINISH WALL WITH 4"x16"TILE

NEW VCTFLOORING

A2.5

5

6

7

8

6'-4"

8'-6"

7'-1"

3'-4"

12'-8

"

W. WASHROOM

255

2-W3FINISH WALL WITH 4"X16"TILE ABOVE COUNTERTOPELEVATION

NEW TOILET PARTITIONS

NEW VCTFLOORING

20A2.4

PRAYER

258

A2.5

11

12

9

10

2W2

11'-4"

17'-4

"

NEW VCTFLOORING

8'-0"

0'-4"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

AIRRETURNCHASE

VENT

6'-9" 5'-3 1/2"

4'-3"

2'-10

1/2

"

8'-0"

0'-4"

PAINTEDBLOCK

RUBBER BASE VCT

PAINTED CONCRETECEILING

TYPE 1 -EPSON WHITEBOARD - 96"MODEL    V12H468001MOUNTING HT. TO BEVERIFIED 8'-

0"

0'-4"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTEDCONCRETE CEILING

8'-0"

0'-4"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

TYPE 2 -WHITEBOARDLOCATION &MOUNTING HT. TO BEVERIFIED

8'-0"

0'-4"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETE CEILING

AIRRETURNCHASE

VENT

TYPE 1 -EPSON WHITEBOARD - 96"MODEL    V12H468001MOUNTING HT. TO BEVERIFIED

6'-9" 3'-0 1/2"

4'-3"

2'-10

1/2

"

8'-0"

0'-4"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTEDCONCRETE CEILING

8'-0"

0'-4"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

NEW PIPE ENCLOSURE

2W2

8'-0"

0'-4"

PAINTEDBLOCK

RUBBER BASE

VCT

PAINTED CONCRETECEILING

AIRRETURNCHASE

6'-9"2'-4 1/2"

TYPE 2 -WHITEBOARDLOCATION &MOUNTING HT. TO BEVERIFIED

6'-0" MIN.

8'-0"

0'-4"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

8'-0"

0'-4"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

8'-0"

0'-4

1/2"

0'-4"

PAINTEDGWB

RUBBER BASEVCT

PAINTED CONCRETECEILING

PAINTEDBLOCK

0'-0

1/2"

8'-0"

0'-4"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

AIRRETURNCHASE

0'-4"

8'-0"

VENT

2'-10 1/2" 6'-9"

4'-3"

2'-10

1/2

"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTEDCONCRETE CEILING

AIRRETURNCHASE

0'-4"

8'-0"

TYPE 1 -EPSON WHITEBOARD - 96"MODEL    V12H468001MOUNTING HT. TO BEVERIFIED

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

0'-4"

8'-0"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

0'-4"

8'-0"

TYPE 2 -WHITEBOARDLOCATION &MOUNTING HT. TO BEVERIFIED

SUPPORT BRACKET @ 36" O.C.MFR. RAKKS, MODEL EH-1824CUT TO SUIT

1'-6"

1" POSTFORMEDLAMINATED COUNTERTOP

SOLID BLOCKING BETWEENSUPPORT BRACKETS0'-

4"

3" X 3/4" CLEAT

4" X 3/4" APRON

1'-6"

2'-8"

PROJECT:

DRAWING TITLE:

DCSC PROJECT NO. OWNER PROJECT NO. REV.

SCALE

CHECKED BY:

DRAWN BY:

DATE:

DRAWING NO.

DCSC LIMITED ARCHITECT & ENGINEERTHUNDER BAY ONTARIO

NO. REVISIONS DATE

As indicated

LAKEHEAD UNIVERSITYPRETTE RESIDENCE ELP RENOVATION

SECOND FLOORENLARGED PLANS & INTERIOR ELEVATIONS

PR14-034

RLN

DCB

MAY 08 / 2015A2.4

1/4" = 1'-0"1 ENLARGED PLAN - MENS WASHROOM

1/4" = 1'-0"2 ENLARGED PLAN - WOMENS WASHROOM

1/4" = 1'-0"3 ENLARGED PLAN - PRAYER ROOM

1/4" = 1'-0"A2.44 ELEVATION 4

1/4" = 1'-0"A2.45 ELEVATION 5

1/4" = 1'-0"A2.46 ELEVATION 6

1/4" = 1'-0"A2.47 ELEVATION 7

1/4" = 1'-0"A2.48 ELEVATION 8

1/4" = 1'-0"A2.49 ELEVATION 9

1/4" = 1'-0"A2.410 ELEVATION 10

1/4" = 1'-0"A2.411 ELEVATION 11

1/4" = 1'-0"A2.412 ELEVATION 12

1/4" = 1'-0"A2.413 ELEVATION 13

1/4" = 1'-0"A2.414 ELEVATION 14

1/4" = 1'-0"A2.415 ELEVATION 15

1/4" = 1'-0"A2.416 ELEVATION 16

1/4" = 1'-0"A2.417 ELEVATION 17

1/4" = 1'-0"A2.418 ELEVATION 18

1/4" = 1'-0"A2.419 ELEVATION 19

1" = 1'-0"A2.420 COUNTER DETAIL

D150101

0 ISSUED FOR TENDER MAY 08 2015

Page 5: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire

VCT

PAINTED CONCRETECEILING

8'-0"

PAINTEDBLOCK

VCT

PAINTED CONCRETECEILING

8'-0"

VCT

PAINTED CONCRETECEILING

2'-8"1'-8" 2'-6"

2'-0"

8'-0"

CERAMIC TILE FINISHNOT SHOWN

PAINTEDBLOCK

VCT

PAINTED CONCRETECEILING

8'-0"

2'-8"

VCT

PAINTED CONCRETECEILING

2'-10"2'-9 1/2"1'-4"

PAINTEDBLOCK8'-

0"

CERAMIC TILE FINISHNOT SHOWN

PAINTEDBLOCK

VCT

PAINTED CONCRETECEILING

2'-8"

8'-0"

PLUMBINGCHASE PAINTED

BLOCK

VCT

PAINTED CONCRETECEILING

8'-0" PAINTED

BLOCK

VCT

PAINTED CONCRETECEILING

8'-0"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

AIRRETURNCHASE

0'-4"

8'-0"

VENT

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

8'-0"

0'-4"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

8'-0"

0'-4"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

AIRRETURNCHASE8'-

0"

0'-4"

PAINTEDBLOCK

PAINTEDBLOCK

PAINTEDBLOCK

PAINTEDGWB

PAINTEDBLOCK

PAINTEDBLOCK

PAINTEDBLOCK

PAINTEDBLOCK

PAINTEDBLOCK

2W4

8'-0"

CONDUITENCLOSURE

VENT VENT VENT VENT VENT VENT

AIR RETURN VENT(COORDINATE w/ MECHANICAL DWG.)

RUBBERBASE

2W4

PAINTEDBLOCK

PAINTEDBLOCK

PAINTEDBLOCK

PAINTEDBLOCK

PAINTEDBLOCK

PAINTEDBLOCK

PAINTEDBLOCK

PAINTEDBLOCK

PAINTEDBLOCKPAINTED

GWB

8'-0"

CONDUITENCLOSURE

VENT VENT VENT VENT VENT

AIR RETURN VENT(COORDINATE w/ MECHANICAL DWG.)

RUBBERBASE

PROJECT:

DRAWING TITLE:

DCSC PROJECT NO. OWNER PROJECT NO. REV.

SCALE

CHECKED BY:

DRAWN BY:

DATE:

DRAWING NO.

DCSC LIMITED ARCHITECT & ENGINEERTHUNDER BAY ONTARIO

NO. REVISIONS DATE

1/4" = 1'-0"

LAKEHEAD UNIVERSITYPRETTE RESIDENCE ELP RENOVATION

SECOND FLOOR INTERIOR ELEVATIONS

PR14-034

RLN

DCB

MAY 08 / 2015A2.5

1/4" = 1'-0"A2.51 ELEVATION 1

1/4" = 1'-0"A2.52 ELEVATION 2

1/4" = 1'-0"A2.53 ELEVATION 3

1/4" = 1'-0"A2.54 ELEVATION 4

1/4" = 1'-0"A2.55 ELEVATION 5

1/4" = 1'-0"A2.56 ELEVATION 6

1/4" = 1'-0"A2.57 ELEVATION 7

1/4" = 1'-0"A2.58 ELEVATION 8

1/4" = 1'-0"A2.5

9 ELEVATION 9 1/4" = 1'-0"A2.5

10 ELEVATION 10 1/4" = 1'-0"A2.5

11 ELEVATION 11 1/4" = 1'-0"A2.5

12 ELEVATION 12

1/4" = 1'-0"13 NORTH-WEST CORRIDOR ELEVATION

1/4" = 1'-0"14 SOUTH-EAST CORRIDOR ELEVATION

D150101

0 ISSUED FOR TENDER MAY 08 2015

Page 6: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire

UP

UP

OFFICE

238

OFFICE

236

RECEPTION

228-30

STAFF

227-29

OFFICE

235

OFFICE

237

OFFICE

239

2W22W2

2W22W22W2

2W1

2W1

D237

D239

D239a

D2C2

D2E1

D2C1

D236D238 D228D2S1

D227D231D235

2W4

2W4

STAIR LANDING

2S1CORRIDOR

2C1

CORRIDOR

2C2D234

MECHANICAL

239a

AREA OFWORK

A2.6

8

9

10

11

OFFICE

239

9'-4"

10'-0

"

4'-4"2W1

D239

A2.6

14

15

12

13

OFFICE

236

9'-4"

14'-6

"

2W2

D236

235 SIM.

SIM.

SIM.

237

238A2.7

6

8

5

7RECEPTION

228-30

9'-4" 10'-0"

14'-6

"4'-

4"

2W2

D228

BULKHEAD ABOVE(SEE STRUCT. DWG)

2W4

A2.7

3

42

1

STAFF

227-29

14'-2"5'-6"

4'-4"

10'-0

"4'-

6"

8'-0"

2W1

2W4

NEW COAT RACK

NEW COUNTERTOP& CABINETRTY

D227D231

BULKHEAD ABOVE(SEE STRUCT. DWG)

8'-0"

PAINTED BLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

0'-4"

8'-0" PAINTED BLOCK

RUBBER BASEVCT

PAINTEDCONCRETECEILING

PAINTEDGWB

0'-4"

8'-0"

D239PAINTEDGWB

RUBBER BASEVCT

PAINTED CONCRETECEILING

PAINTEDBLOCK

0'-4"

8'-0" PAINTED

BLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

0'-4"

8'-0" PAINTED

BLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

0'-4"

2'-1"

AIRRETURNCHASE

VENT

8'-0"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

AIRRETURNCHASE

0'-4"

8'-0"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

0'-4"

8'-0" PAINTED

BLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

0'-4"

2-W2

WALL TYPE LEGEND

2-W1

INTERIOR - NEW AIR RETURN CHASE5/8" TYPE 'X' GYPSUM WALL BOARD250S162-43 STEEL STUDS @ 16" O/C

INTERIOR PARTITION - NEW 3 1/2"5/8" TYPE 'X' GYPSUM WALL BOARD350S162-43 STEEL STUDS @ 16" O/C3 1/2" ABSORPTIVE MATERIAL5/8" TYPE 'X' GYPSUM WALL BOARD

2-W3 INTERIOR - NEW PLUMBING CHASE5/8" TYPE 'X' GYPSUM WALL BOARD350S162-43 STEEL STUDS @ 16" O/C

2-W4 INTERIOR - NEW 6" INFILL WALL5/8" TYPE 'X' GYPSUM WALL BOARD600S162-43 STEEL STUDS @ 16" O/C6" ABSORPTIVE MATERIAL5/8" TYPE 'X' GYPSUM WALL BOARD

PROJECT:

DRAWING TITLE:

DCSC PROJECT NO. OWNER PROJECT NO. REV.

SCALE

CHECKED BY:

DRAWN BY:

DATE:

DRAWING NO.

DCSC LIMITED ARCHITECT & ENGINEERTHUNDER BAY ONTARIO

NO. REVISIONS DATE

As indicated

LAKEHEAD UNIVERSITYPRETTE RESIDENCE ELP RENOVATION

SECOND FLOOR ADMINISTRATIONPLANS, ENLARGED PLANS, ELEVATIONS

PR14-034

RLN

DCB

MAY 08 / 2015A2.6

1/8" = 1'-0"5 SECOND FLOOR PLAN - ADMINISTRATION

1" = 100'-0"1 KEY PLAN - SECOND FLOOR

1/8" = 1'-0"2 REFLECTED CEILING PLAN - ADMINISTRATION

1/4" = 1'-0"3 ENLARGED PLAN - OFFICE A

1/4" = 1'-0"4 ENLARGED PLAN - OFFICE B

1/4" = 1'-0"6 ENLARGED PLAN - RECEPTION

1/4" = 1'-0"7 ENLARGED PLAN - STAFF

1/4" = 1'-0"A2.68 ELEVATION 8

1/4" = 1'-0"A2.69 ELEVATION 9

1/4" = 1'-0"A2.610 ELEVATION 10

1/4" = 1'-0"A2.611 ELEVATION 11

1/4" = 1'-0"A2.612 ELEVATION 12

1/4" = 1'-0"A2.613 ELEVATION 13

1/4" = 1'-0"A2.614 ELEVATION 14

1/4" = 1'-0"A2.615 ELEVATION 15

D150101

0 ISSUED FOR TENDER MAY 08 2015

Page 7: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire

8'-0"

9'-4"10'-4"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTEDCONCRETECEILING

0'-4"

8'-0"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTEDCONCRETECEILING

PAINTEDBLOCK

0'-4"

8'-0" PAINTED

BLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

0'-4"

VENT

ADJ. SHELF

ADJ. SHELF ADJ. SHELF

ADJ. SHELF

2'-9" 2'-9"

2'-0"

2'-0"

3'-0

1/2"

8'-0"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

EXISTINGBRICK

0'-4"

8'-0"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTEDCONCRETECEILING

0'-4"

AIRRETURNCHASE

VENT

8'-0"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

0'-4"

8'-0"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

0'-4"

AIRRETURNCHASE

8'-0"

PAINTEDBLOCK

RUBBER BASEVCT

PAINTED CONCRETECEILING

0'-4"

4"

2'- 0

"

1'-1 3/4"

1'-10 1/2"

3"

2'-0"

3'-1

1/2"

4"

PROVIDE DOOR PULLS & LOCKS

32mm SYSTEM HOLES

UNFINISHED TOEKICK

SINK

PROVIDE DOOR PULL & LOCKS

32mm SYSTEM HOLES

24

13

1013

2

3

21

2

4

PROJECT:

DRAWING TITLE:

DCSC PROJECT NO. OWNER PROJECT NO. REV.

SCALE

CHECKED BY:

DRAWN BY:

DATE:

DRAWING NO.

DCSC LIMITED ARCHITECT & ENGINEERTHUNDER BAY ONTARIO

NO. REVISIONS DATE

As indicated

LAKEHEAD UNIVERSITYPRETTE RESIDENCE ELP RENOVATION

SECOND FLOOR RENOVATEDINTERIOR ELEVATIONS

PR14-034

RLN

DCB

MAY 08 / 2015A2.7

1/4" = 1'-0"A2.71 ELEVATION 1

1/4" = 1'-0"A2.72 ELEVATION 2

1/4" = 1'-0"A2.73 ELEVATION 3

1/4" = 1'-0"A2.74 ELEVATION 4

1/4" = 1'-0"A2.75 ELEVATION 5

1/4" = 1'-0"A2.76 ELEVATION 6

1/4" = 1'-0"A2.77 ELEVATION 7

1/4" = 1'-0"A2.78 ELEVATION 8

1" = 1'-0"MILLWORK - STAFF ROOM CABINET9

MATERIAL LEGEND

19mm MAPLE VENEER CORE PLYWOOD c/w3MM SOLID MAPLE HARDWOOD EDGING

19mm WHITE MELAMINE c/w PVC TAPE TOMATCH DOOR & DRAWER

19mm WHITE MELAMINE c/w MATCHING PVCTAPE

6mm PREFINISHED WHITE HARDBOARD

25mm PARTICLE BOARD c/w PLASTICLAMINATE BACKER, 3mm PVC EDGING

19MM PARTICLE BOARD CLAD WITH PLASTICLAMINATE ON EXPOSED FACE ONLY c/w 3mmPVC MATCHING EDGING

1-

1-

1-

1-

1-

1-

D150101

0 ISSUED FOR TENDER MAY 08 2015

Page 8: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire

SEM

INAR

240

ACAD

EMIC

242-4

4

SERV

ICE

243

SEM

INAR

246

ACAD

EMIC

245-4

7

ACAD

EMIC

248-5

0

SEM

INAR

249

ACAD

EMIC

251-5

3

M. W

ASHRO

OM

254

W. W

ASHRO

OM

255

ACAD

EMIC

257-5

9

SHO

WERS

----

PRAYER

258

SEM

INAR

261

OFFIC

E

260

HALLW

AY262

STAIRW

ELL

263

OFFIC

E

238

OFFIC

E

236

ADM

IN.

228-3

0

STAFF

227-2

9

OFFIC

E

235

OFFIC

E

237

OFFIC

E

239

Web: w

ww.sostratus.ca

e-mail: info@

sostratus.caFx: (8

07) 3

46-1

344Ph: (8

07) 3

46-1

340

Canada P7A 4L8

Thunder Bay, O

ntario208 - 7

3 N

. Cum

berland StreetSostratus Engineering Ltd.

Page 9: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire

EXCH

CORRIDOR

EXCH

EX

EXCH

EX

EX

RM

EXEX

NEW EX

RM

EXCH

EXCH

EX EX

EXCH

EXCH

EXCH

EX

RM

AVx2

AV

EX EX

EXCH

EXCH

AVx2

AVAVx2

AV

AVx2

AV

AVx2

AV

EX EX

EXCH

EXCH

EX EX

EXCH

EXCH

EX

EXCH

EXCH

EXCH

EX

RMCH

RMCH

RMCH

RMCH

EX

EXCH

EXCH

AVx2

AV

EX

EX

EXCH

EXCH

AVx2

AV

AVx2

AV

AVx2

AV

EX

EX

EXCH

RM

EX

EXCH

EXCH

EXCH

EXCH

EX

EX

WIFIAVx2

WIFIAVx2

WIFIAVx2

WIFIAVx2

WIFIAVx2

AVx2

WIFI

AVx2

WIFI

AVx2

WIFI

AVx2

WIFI

AVx2

WIFI

NEW DATA CABLINGCONDUIT, SEEPOWER NOTE 5.

3/4" DIA CONDUIT FOR NEWDATA CABLING INTO NEWCLASSROOM, TYPICAL.

OFFICE

260

SEMINAR

261

ACADEMIC

257-59

W. WASHROOM

255

ACADEMIC

251-53

SEMINAR

249

ACADEMIC

245-47

SERVICE

243

SEMINAR

240

ACADEMIC

242-44

SEMINAR

246

ACADEMIC

248-50

M. WASHROOM

254

SHOWERS

256

PRAYER

258

EX

EX

EX EX EX EX

EX

EX EX

EX

EX EX

EX

EX EX

EX

RM RM RM

RM

RMEX

RM

EX

RM

RM

RM

EXISTING PANEL 'A',POWER NOTE 7.

NEW HYDRONIC HEATING, SEE NOTE 4.

NEW HYDRONIC HEATING, SEE NOTE 4.

NEW HYDRONIC HEATING, SEE NOTE 4.

NEW HYDRONIC HEATING, SEE NOTE 4.

NEW HYDRONIC HEATING, SEE NOTE 4.

NEW HYDRONIC HEATING, SEE NOTE 4.

NEW HYDRONIC HEATING, SEE NOTE 4.

NEW HYDRONIC HEATING, SEE NOTE 4.

NEW HYDRONIC HEATING, SEE NOTE 4.

NEW HYDRONIC HEATING,SEE NOTE 4.

NEW HYDRONIC HEATING, SEE NOTE 4.

EXISTING DEVICESTO REMAIN

EXEX

HRV-1A-3/4/5

EX EX

FIELD LOCATE NEW SMOKEDETECTORS TO AVOID NEWDUCTWORK. REFER TO MECHDRAWINGS, TYPICAL.

A-1

A-1A-1

A-1

A-1

A-2

A-2

A-2

A-2

A-2

SEE POWERNOTE 8.

SEE POWERNOTE 8.

SECOND FLOOR ACADEMIC AREA POWER NOTESALL EXISTING TELEPHONE DEVICES, WIRING AND TERMINAL STRIPS TO BEREMOVED.

ALL EXISTING DATA OUTLETS TO REMAIN.

ALL EXISTING CABLE TELEVISION DEVICES AND WIRING TO BE REMOVED.

NEW HYDRONIC HEATING TO BE INSTALLED ALONG EXTERIOR WALLS OFAREA AT FLOOR. REFER TO MECHANICAL DRAWINGS FOR EXACTLOCATIONS. RELOCATE DEVICES AS REQUIRED.

1.

2.

3.

4.

2" DIA CONDUIT FOR NEW DATA CABLING INTO CLASSROOMS. CONDUITMOUNTED IN NEW ARCHITECTURAL RACEWAY ABOVE DOORS. REFER TOARCHITECTRUAL DETAILS. PROVIDE JUNCTION BOXES WHERE REQUIRED,COORDINATE JUNCTION BOX SIZES WITH ARCHITECTURAL DETAILS.

5.

REMOVE ALL DEVICES IN DEMOLISHED WALLS, MAINTAIN EXISTING CIRCUITINTEGRITY.

6.

TO MAKE ROOM FOR NEW CIRCUITS IN PANEL 'A' ELECTRICAL CONTRACTORSHALL ADD TANDEM BREAKERS TO SUIT PANEL.

7.

PROVIDE LV POWER FOR ALL NEW URNIALS AND LAVS IN WASHROOMS. FIELDLOCATE, PROVIDE TRANSFORMER, COODINATE WITH MECHANICAL. CONNECTTO CIRCUIT 'A-6'.

8.

A-1

PHASE A PHASE B PHASE C

VA WIRE ANDCONDUIT SIZE

VOLTSPOLESSIZE

BREAKERCIRCUIT USE

CCT. No.

A-2

A-3

A-4

A-5

N E W P A N E L ' A ' C I R C U I T S

NOTES:- RE-USE EXISTING CIRCUITS, GROUP THE FIXTURES/DEVICES AS SHOWN IN THIS SCHEDULE.

600

600

762

762

2c#12 AWG IN EMT

2c#12 AWG IN EMT

3c#10 AWG IN EMT

762

NEW AV RECEPTACLES

NEW AV RECEPTACLES

NEW HRV-1

15A 1 120

15A 1 120

20A 3 208

A-6 120 2c#12 AWG IN EMTLV POWER, MECHANICAL CONTOL POWER 15A 1 120

MAY 8/2015GENERAL SPECIFICATIONS1. INSTALLATION SHALL BE IN ACCORDANCE WITH THE ONTARIO HYDRO

ELECTRICAL SAFETY CODE LATEST EDITION & ALL OTHER APPLICABLECODES & REGULATIONS.

2. ALL EQUIPMENT SHALL BE NEW AND CSA CERTIFIED.

3. ELECTRICAL CONTRACTOR SHALL SUPPLY EQUIPMENT AS SPECIFIED ASWELL AS ANY MISCELLANEOUS TO COMPLETE THE WORK.

4. IDENTIFY ELECTRICAL EQUIPMENT WITH PROPER NAMEPLATES. IDENTIFY ALLWIRING, MAINTAIN PHASE SEQUENCE & COLOUR CODING.

5. CONTRACTOR TO FURNISH CERTIFICATES OF ACCEPTANCE FROM THEELECTRICAL INSPECTION DEPARTMENT UPON COMPLETION OF WORK TO THEENGINEER. REVERIFY F/A SYSTEM BY QUALIFIED PERSONNEL. CONDUCTAUDITORY TEST UPON COMPLETION.

6. ALL WIRING SHALL BE MIN. #12 AWG Cu. IN EMT (UNLESS OTHERWISENOTED).

7. INSTALL INSULATED GREEN BONDING CONDUCTOR IN ALL EMT CONDUIT.

8. ALL WIRING SHALL BE CONCEALED FROM VIEW UNLESS OTHERWISENOTED.

9. ELECTRICAL CONTRACTOR SHALL MAKE A PERSONAL SITE VISIT ANDCONFIRM ALL QUANTITIES/LOCATION/MOUNTING PRIOR TO SUBMITTINGQUOTE.

10. CONTRACTOR SHALL REPAIR ALL SURFACES DAMAGED DUE TO WORKPERFORMED.

11. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, DO NOT SCALEDRAWING.

12. ALL MATERIALS REMOVED AND MADE REDUNDANT BY THIS WORK (UNLESSINDICATED OTHERWISE) SHALL BECOME PROPERTY OF OWNER.

13. MOUNTING HEIGHTS FOR DEVICES AS PER CODE REQUIREMENTS, UNLESSOTHERWISE NOTED.

14. COORDINATE COLOUR FOR ALL WALL PLATES, RECEPTACLES, SWITCHESAND DEVICES WITH OWNER.

15. MOUNT ALL EMERGENCY LIGHTING AT 7'-0" ABOVE FINISHED FLOOR.PROVIDE RECEPTACLE ABOVE CEILING AS REQUIRED.

16. COORDINATE ALL LIGHT FIXTURE AND RECEPTACLE INSTALLATION INMILLWORK WITH CABINET BUILDER.

17.

19. ELECTRICAL CONTRACTOR TO SUPPLY AND INSTALL ALL FUSED AND NON-FUSED DISCONNECTS AS REQUIRED FOR ALL MECHANICAL EQUIPMENTINDICATED ON ELECTRICAL AND MECHANICAL DRAWING SETS. AMPERAGE,VOLTAGE AND NUMBER OF POLES TO BE CONFIRMED WITH MANUFACTURER'SLITERATURE.

20. COMPLETE TYPEWRITTEN PANEL SCHEDULES ARE TO BE PROVIDED FOR ALLPANELS. ALL LOADS FED FROM RELOCATED EXISTING CIRCUITS ARE TO BEDETERMINED AND INCLUDED IN PANEL SCHEDULES.

18. THE INTENT OF THIS PROJECT IS INSTALL A COMPLETE LIGHTING DESIGN.IF SWITCHING FOR AN AREA IS NOT SHOWN, THE ELECTRICALCONTRACTOR SHALL PROVIDE SWITCHING.

21. ALL ELECTRICAL EQUIPMENT WITHIN SPRINKLERED ROOMS SHALL BEEQUIPPED WITH HOODS SUITED FOR THE APPLICATION. IF HOODS ARE NOTPROVIDED BY THE FACTORY OR IT IS FOR AN EXISTING PIECE OFEQUIPMENT, IT SHALL BE THE ELECTRICAL CONTRACTORSRESPONSIBILITY TO SUPPLY AND INSTALL THESE HOODS ON NEW OREXISTING EQUIPMENT AS REQUIRED.

22. ALL CEILING SPACES IN RENOVATION AREAS ACT AS RETURN AIRPLENUMS. ALL CABLING IN CEILING SPACE MUST HAVE AN FT6 FIRERATING OR BE COMPLETELY ENCLOSED IN CONDUIT.

GENERAL DEMOLITION NOTES1. REMOVE ALL UNNECESSARY EXISTING ELECTRICAL EQUIPMENT, WIRING, &

FIXTURES IN THOSE PORTIONS OF THE EXISTING BUILDING WHICH ARE BEINGREMODELED OR DEMOLISHED. THE ELECTRICAL CONTRACTOR SHALLREMOVE ALL REDUNDANT EQUIPMENT FROM SITE. ANY ELECTRICALEQUIPMENT IN REMODELED SECTIONS OR IN STRUCTURES REMOVED ORALTERED, ADJACENT TO NEW WORK, NECESSARY FOR THE OPERATION OFEXISTING BUILDING, SHALL BE RELOCATED AS NECESSARY. ALL EXISTINGEQUIPMENT REUSED SHALL BE MADE GOOD AND GUARANTEED. REVISEPANEL SCHEDULES TO SUIT.

3. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS AND NOTES ANDCOORDINATE AS REQUIRED.

2. ALL REDUNDANT EQUIPMENT MAY NOT APPEAR IN DRAWING SET. IT IS THERESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO REMOVE ALLREDUNDANT EQUIPMENT AND ADHERE TO DEMOLITION NOTE #1 IN ALLCASES.

PROVIDE DEDICATED 1P-15A BREAKER FOR EXIT SIGN POWER.

23. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL 20A GFI NEMA 5-20RCONVENIENCE RECEPTACLE(S) WITHIN 7.5m OF ALL ROOFTOP MOUNTEDMECHANICAL EQUIPMENT (HEATING, VENTILATION, AIR CONDITIONINGUNITS). ALL RECEPTACLES TO BE FED FROM DEDICATED 1P-20A CIRCUIT(S),AND MOUNTED IN WEATHERPROOF BACKBOX W/ SPRING-LOADED COVER,MINIMUM 750mm ABOVE FINISHED ROOF.

LIGHTING IDENTIFICATION LEGEND

LED TROFFER FIXTURE, 120V, 43W, 3500°, 4100 LUMEN,12"x48"PHILIPS CFI DAY-BRITE SERIESCAT# 1-DL-G-41L-835-4-D-UNV

T1

TOGGLE SWITCH, BACK/SIDE WIRED, 15A, 120/277V,LEVITON CAT. # 1201 OR EQUAL.

BARRIER-FREE DOOR OPERATOR AND ASSOCIATEDPUSHBUTTONS. ALL POWER AND CONTROL WIRING BYELECTRICAL CONTRACTOR. INSTALL CONDUIT AND RECESSEDBOXES FOR PUSHBUTTONS AS REQUIRED. COORDINATE WITHDOOR HARDWARE SUPPLIER/INSTALLER.

DUPLEX RECEPTACLE

FIRE ALARM PULLSTATION

LED SURFACE-MOUNT FIXTURE, 120V, 50W, 3500°,12"x48", MATTE WHITE FINISH, FLAT END CAP,KENALL MILLENIUM STRETCH SERIESCAT# MLHA12-48-F-MW-PP-45L35K-DCC-1-120

S1

LED WALL-MOUNT FIXTURE, 120V, 25W, 3500°,8"x24", MATTE WHITE FINISH, FLAT END CAP,C/W CORNER MOUNT BRACKETKENALL MILLENIUM STRETCH SERIESCAT# MLHA8-24-F-MW-PP-25L35K-DCC-1-120-CMB

S2

THREE-WAY TOGGLE SWITCH, BACK/SIDE WIRED, 15A,120/277V, LEVITON CAT. # 1203 OR EQUAL.

3W

LED "RUNNING MAN" EXIT SIGN W/ PICTOGRAM SYMBOLSCONFORMING TO ISO 7010. EXTRUDED ALUMINUM FRAME W/CLEAR POLYCARBONATE PANELS AND PICTOGRAM FILMS.SELF-POWERED WITH NICKLE-CADMIUM BATTERY SIZED FOR2 HOURS BACKUP. UNIVERSAL VOLTAGE (120V-347V).SINGLE OR DOUBLE FACED TO SUIT AND PICTOGRAM FILMSTO DENOTE EXIT DIRECTIONS AS NOTED ON DRAWINGS.EMERGI-LITE# EA SERIES

'EM' DENOTES A LIGHT FIXTURE FED FROM EMERGENCYPOWER PANEL 'EM' LOCATED IN BASEMENT.

EM

POWER/SYSTEMS IDENTIFICATION LEGEND

GFI RECEPTACLE

20A GFI RECEPTACLE20A

NEW COMMUNICATIONS OUTLET. PROVIDE 3/4" EMTRACEWAY TO CEILING SPACE C/W PULL CORD.

EXISTING VOICE/DATA OUTLET

EXISTING TELEPHONE OUTLET

EXISTING CABLE TELEVISION OUTLET

FIRE ALARM BELL

FIRE ALARM HEAT DETECTOR

FIRE ALARM SMOKE DETECTOR

'AV' DENOTES DEVICES FOR AUDIO/VISUAL EQUIPMENT TOBE MOUNTED AT HIGH LEVEL, NEAR CEILING.

AV

'CH' DENOTES DEVICE WALL-MOUNTED AT COUNTERHEIGHT.

CH

'EX' DENOTES EXISTING DEVICE TO BE REMOVED ANDREPLACED WITH NEW.

EX

'RM' DENOTES EXISTING DEVICE TO BE REMOVED C/W ALLWIRING TO SOURCE. MAINTAIN CIRCUIT INTEGRITY.

RM

'RL' DENOTES DEVICE TO BE REMOVED AND REUSED IN NEWLOCATION. EXTEND WIRING AND CONDUIT AS REQUIRED.REFER TO DEMOLITION PLANS, RENOVATION PLANS, GENERALELECTRICAL CONSTRUCTION NOTES AND SPECIFICATIONS. - REUSE OF LIGHTING FIXTURES WILL REQUIRE THE FIXTURE BE CLEANED, RELAMPED AND BALLAST CHANGED. - RELOCATION OF FIRE ALARM SMOKE DETECTORS, HEAT DETECTORS AND PULLSTATIONS ARE TO BE REPLACED WITH NEW DEVICES AT NEW LOCATION.

RL

'RP' DENOTES EXISTING DEVICE TO BE REPLACED WITH NEW.RP

PLOT SCALE:

DRAWN BY:

APPROVED BY:PROJECT No.

DWG SCALE:

DATE ISSUED:

DRAWING TITLE

DWG No. REV.

DATEBYNo. DESCRIPTION

PROJECT TITLE

A.G. Engineering

Electrical Engineers

Thunder Bay Inc.1111 E. Victoria Ave., 2nd FlrThunder Bay, ON, P7C 1B7Phone : (807) 622-3654Cell: (807) 627-8194Fax: (807) 622-3633

1:1

0 ISSUED FOR PERMIT & TENDER GAP MAY 8 2015

0

As indicated

Lakehead University

Second Floor Academic AreaPower Layout

May 2015

A111-15-001

E1-1

GAP

AG

Prettie Residence ELP Renovation

SECOND FLOOR ACADEMIC AREA - POWER LAYOUTSCALE 1:50

Page 10: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire

S1

CORRIDOR

RM

S1 S1

S1

S1

S1

S1S1

S1

S1

S1

S1

3W3W

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

3W3W3W3W

3W3W 3W3W

S2

3W

SHOWERS

256

PRAYER

258

OFFICE

260

SEMINAR

261

ACADEMIC

257-59

W. WASHROOM

255

M. WASHROOM

254

ACADEMIC

251-53

ACADEMIC

245-47

SERVICE

243

SEMINAR

240

ACADEMIC

242-44

ACADEMIC

248-50

SEMINAR

249

SEMINAR

246

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2S2S2

S2

S2

S2

S2

RM

RM

EXISTINGLIGHTING TO

REMAIN

EXISTING LIGHTINGTO REMAIN

RM

EXISTING LIGHTINGTO REMAIN

EXISTING LIGHTINGTO REMAIN

S2

RM

RM

RM EXISTING LIGHTINGTO REMAIN

S2EM EM EM EM EMEM

S2

SECOND FLOOR ACADEMIC AREA LIGHTING NOTES1. CONNECT ALL NEW LIGHTING TO EXISTING LIGHTING CIRCUITS FOR

AREA, CONFIRM CIRCUIT LOADING, ADD CIRCUITS IF REQUIRED.

2. NEW CORRIDOR LIGHTING TO BE CONNECTED TO EXISTINGCORRIDOR LIGHTING CIRCUIT FOR POWER AND EXISTINGSWITCHING FOR CONTROL.

3. CORRIDOR LIGHTING TO BE MOUNTED BELOW ARCHITECTUALVALENCE, REFER TO ARCHITECTUAL DRAWINGS.

4. RUN NEW WIRING IN SURFACE-MOUNT RACEWAYS, CONCEALNEW WIRING IF POSSIBLE.

MAY 8/2015

PLOT SCALE:

DRAWN BY:

APPROVED BY:PROJECT No.

DWG SCALE:

DATE ISSUED:

DRAWING TITLE

DWG No. REV.

DATEBYNo. DESCRIPTION

PROJECT TITLE

A.G. Engineering

Electrical Engineers

Thunder Bay Inc.1111 E. Victoria Ave., 2nd FlrThunder Bay, ON, P7C 1B7Phone : (807) 622-3654Cell: (807) 627-8194Fax: (807) 622-3633

1:1

0 ISSUED FOR PERMIT & TENDER GAP MAY 8 2015

0

As indicated

Lakehead University

Second Floor Academic AreaLighting Layout

May 2015

A111-15-001

E1-2

GAP

AG

Prettie Residence ELP Renovation

SECOND FLOOR ACADEMIC AREA - LIGHTING LAYOUTSCALE 1:50

Page 11: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire

RMEX

EX

RM

RM

RM

RM

EX

RM

EX

RM

RM

W/R

STAIRCORRIDOR H

RM

CLOSET

EXISTINGLIGHTING TO

REMIAN

EXISTINGLIGHTING TO

REMIAN

TIE NEW CORRIFORLIGHTING INTO EXISTINGCIRCUIT & SWITCHING.

OFFICE

238

OFFICE

236

RECEPTION

228-30

OFFICE

239

OFFICE

237

OFFICE

235

STAFF

227-29

EF-2

EF-1B-6

EM EM

W/R

EX

CH20A

CH20A

RM

EX

EXRM

EXEX

EX

EX

EX

RM

EX

EX

EX

EX

EX

STAIRCORRIDOR H

RM

EX

RM

EX

EX EX

EX EX EX

EX

EX RLRELOCATE PULLSTATION TOACCOMODATE NEWSIGHLIGHT WINDOW.

EX

EXISTING PANEL 'B'POWER NOTE 6.

POWERNOTE 5.

RM

EX

EX

EX

RM

EX

RM

RECEPTION

228-30

OFFICE

236

OFFICE

238

OFFICE

239

OFFICE

237

OFFICE

235

STAFF

227-29

RP

HRV-2B-7

CONDENSATEPUMP B-7

4kW DUCTHEATER HC#3B-4/5

EX EX EX EX EX

EXEXEXEX

EX

B-1

B-2

B-2B-2

B-2

B-2

B-1

B-1

POWER NOTE 7.

MECH CONTROLSPOWER, B-3

B-1

B-8 B-8POWER NOTE 8.

SECOND FLOOR ADMIN AREA LIGHTING NOTES1. CONNECT ALL NEW LIGHTING TO EXISTING LIGHTING CIRCUITS FOR

AREA, CONFIRM CIRCUIT LOADING, ADD CIRCUITS IF REQUIRED.

2. NEW CORRIDOR LIGHTING TO REPLACE EXISTING WALL-MOUNTLIGHT FIXTURES. CONNECT TO EXISTING CIRCUIT FOR POWER ANDSWITCHING FOR CONTROL.

3. RUN NEW WIRING IN SURFACE-MOUNT RACEWAYS, CONCEAL NEWWIRING IF POSSIBLE.

SECOND FLOOR ADMIN AREA POWER NOTESALL EXISTING TELEPHONE DEVICES, WIRING AND TERMINALSTRIPS TO BE REMOVED.

ALL EXISTING DATA OUTLETS TO REMAIN.

ALL EXISTING CABLE TELEVISION DEVICES AND WIRING TO BEREMOVED.

1.

2.

3.

4. REMOVE ALL DEVICES IN DEMOLISHED WALLS, MAINTAINEXISTING CIRCUIT INTEGRITY.

5. 2x 2" EMT CONDUIT FROM CRAWLSPACE FOR DATA CABLING.

6. TO MAKE ROOM FOR NEW CIRCUITS IN PANEL 'B' ELECTRICALCONTRACTOR SHALL ADD TANDEM BREAKERS TO SUIT PANEL.

7. PROVIDE 20A T-SLOT RECEPTACLE FOR CONDENSATE PUMP.

8. PROVIDE 20A T-SLOT RECEPTACLE FOR HRV-2.

B-1

PHASE A PHASE B PHASE C

VA WIRE ANDCONDUIT SIZE

VOLTSPOLESSIZE

BREAKERCIRCUIT USE

CCT. No.

B-2

B-3

B-4

B-5

B-6

N E W P A N E L ' B ' C I R C U I T S

NOTES:- RE-USE EXISTING CIRCUITS, GROUP THE FIXTURES/DEVICES AS SHOWN IN THIS SCHEDULE.

480

600

120

2000

2c#12 AWG IN EMT

2c#12 AWG IN EMT

2c#12 AWG IN EMT

2c#10 AWG IN EMT2000

NEW DATA RECEPTACLES

NEW RECEPTACLES

MECHANICAL CONTROLS

4kW DUCT HEATER HC#3

15A 1 120

15A 1 120

15A 1 120

30A 2 208

2c#12 AWG IN EMTEXHAUST FAN EF-1 15A 1 120 200

B-7

B-8

500 2c#12 AWG IN EMT

750 2c#12 AWG IN EMT

HRV-2 & CONDENSATE PUMP

20A GFI RECEPTACLES

15A 1 120

20A 1 120

MAY 8/2015

PLOT SCALE:

DRAWN BY:

APPROVED BY:PROJECT No.

DWG SCALE:

DATE ISSUED:

DRAWING TITLE

DWG No. REV.

DATEBYNo. DESCRIPTION

PROJECT TITLE

A.G. Engineering

Electrical Engineers

Thunder Bay Inc.1111 E. Victoria Ave., 2nd FlrThunder Bay, ON, P7C 1B7Phone : (807) 622-3654Cell: (807) 627-8194Fax: (807) 622-3633

1:1

0 ISSUED FOR PERMIT & TENDER GAP MAY 8 2015

0

As indicated

Lakehead University

Second Floor Administration AreaPower & Lighting Layout

May 2015

A111-15-001

E2-1

GAP

AG

Prettie Residence ELP Renovation

SECOND FLOOR ADMINSTRATION AREA - LIGHTING LAYOUTSCALE 1:50

SECOND FLOOR ADMINSTRATION AREA - POWER LAYOUTSCALE 1:50

Page 12: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire
Page 13: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire
Page 14: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire
Page 15: A2 Floor... · door/frame/hardware schedule room door frame no. name type thickness height width material finish insulated fire rating glazing material finish thermally broken fire