aama standards comparison - windows, doors, and unit … · aama standards comparison - windows,...

1
Proud Member of: Copyright® 2012 Revisions and Addional Requirements as Compared to 1997 Version AAMA/WDMA 101/I.S.2-97 101/I.S.2/NAFS-02 AAMA/WDMA/CSA 101/I.S.2/A440- 05 AAMA/WDMA/CSA 101/I.S.2/A440- 08 AAMA/WDMA/CSA 101/I.S.2/A440-11 Format Combined Combined Combined Combined Separate Secons for products, materials, and components Basis of Rang IP Only IP Primary (Metric Oponal) IP Primary (Metric Oponal) IP Primary (Metric Oponal) IP Primary (Metric Oponal) Compliance Measurement Units IP Primary (Metric Secondary) Metric Primary (IP Secondary) Metric Primary (IP Secondary) Metric Primary (IP Secondary) Metric Primary (IP Secondary - Hard Conversion) # of Product Operator Types 20 26 30 31 36 # of Performance Classificaons 5 (R, LC, C, HC, and AW) 5 (R, LC, C, HC, and AW) 5 (R, LC, C, HC, and AW) 4 (R, LC, CW, and AW) 4 (R, LC, CW, and AW) Alternave Minimum Test Size and minimum performance grades (PG) for Class R products (Clause 9) Not Included Not included Not included Added Included Operator Type Codes F, DA, HGD & SGD same as 93 F, DA, HGD & SGD same as 93 Chg to FW, FD, DAW, SHD & SD FW, FD, DAW, SHD & SD FW, FD, DAW, SHD & SD Performance Grade Caps No upper limit on Grade (Design Pressure) Upper limit of 60 psf above Gateway except AW Upper limit of 60 psf above Gateway except AW Increased to 100 psf for R, LC, and CW classes. No limit for AW 100 psf for R, LC, and CW classes. No limit for AW U.S. Operang Force (SGD/SD require both forces) Force to maintain moon ONLY Force to iniate and maintain moon Force to maintain moon but test and record force to iniate Force to maintain moon but test and record force to iniate Force to maintain moon but test and record force to iniate Canadian Operang Force Not included Not included Force to maintain moon and force to iniate based on performance class Force to maintain moon and force to iniate based on applicaon Force to maintain moon and force to iniate based on applicaon Air Leakage 0.3 and 0.1 cfm/ſt2 0.3 cfm/ſt2 ONLY 0.3 and 0.1 cfm/ſt2 0.3 and 0.1 cfm/ſt2 0.3 and 0.1 cfm/ſt2 Canadian Air Leakage Not included Oponal levels Oponal levels Oponal levels Oponal levels Frame/Sash Deflecon Limits AW and HC Hung ONLY AW and HC ONLY AW and HC ONLY AW and CW ONLY AW and CW ONLY Glass Deflecon Limits Excepon Noted Excepon Noted Excepon Noted Excepon Noted Excepon Noted Frame/Sash Permanent Deformaon 0.4% (0.2% for AW) 0.4% (0.2% for AW) 0.4% for R & LC, 0.3% for C & HC, 0.2% for AW 0.4% for R & LC, 0.3% for CW, 0.2% for AW 0.4% for R & LC, 0.3% for CW, 0.2% for AW Forced Entry Resistance Standard ASTM, CMBSO, or AAMA ASTM, CMBSO, or AAMA ASTM ONLY ASTM ONLY ASTM ONLY Force to Latch requirement (SHD) Not included Not included 65 N (15 lbf) Test and record only Test and record only Glass Strength Standard - basis of glass selecon ASTM E 1300-94 - use weakest glass for tesng ASTM E 1300-00 - use weakest & thinnest glass for tesng ASTM E 1300-02 - use weakest glass for tesng ASTM E 1300-02 - use weakest glass for tesng ASTM E 1300-09a - use weakest glass for tesng Hardware Lead Content Requirements Not included Not included Not included Not included Added Parallel Opening Windows Not included Not included Not included Not included Added Plasc Glazing Requirements No Requirements No Requirements Added 6 requirements No addional requirements No addional requirements Materials Referenced Aluminum, Wood and Vinyl Added 7 addional materials Added 2 addional materials No addional materials No addional materials Mullion Definions and Illustraons Definion Only Examples & Illustraons Expanded Explanaon Expanded Explanaon Added new rangs and designaons Secondary Storm Products Not included Not included Not included Not included Added new rangs and designaons Skylights, Sidelites & Transoms Not included Added Added & Expanded Added & Expanded Added new designaons for TDDs and eliminated Skylight Performance Classes. Side-Hinged Exterior Doors Not included Not included Added Included Included Side-Hinged Door Systems Operaon/Cycling (Clause 5.3.6.10) Not included Not included R (25,000), LC (100,000), C (250,000), HC (except ATD-500,000), HC (ATD- 25,000), AW (except ATD-1,000,000), AW (ATD-25,000) R (25,000), LC (100,000), CW (250,000), AW (except ATD-500,000), AW (ATD-25,000) R (25,000), LC (100,000), CW (250,000), AW (except ATD-500,000), AW (ATD- 25,000) Side-Hinged Exterior Door Glazing Excepon 5 (Clause 6.2.3.4.6) Not included Not included Not included Added - such specimens shall use the heaviest glass assembly that is to be qualified or shall have sufficient weight aached to the glazing to make it equivalent to the heaviest glazing assembly to be qualified. Added - such specimens shall use the heaviest glass assembly that is to be qualified or shall have sufficient weight aached to the glazing to make it equivalent to the heaviest glazing assembly to be qualified. Architectural Terrace Doors Not included Not included Added Included Included Limited Water Rang for SHD Not included Not included Added Included Included Primary Designator (example class R casement) C-R25 30 x 60 C-R25 760 x 1520 (30 x 60) C-R25 760 x 1520 (30 x 60) Class R-PG25: Size tested 760 × 1520 mm (30 × 60 in)-Casement Class R-PG25: Size tested 760 × 1520 mm (30 × 60 in)-Casement Secondary Designator Not included Not included Added Added Prescripve requirements idenfied in Clause 4.4.3.1 for the use of Secondary Designators Prescripve requirements idenfied in Clause 4.4.3.1 for the use of Secondary Designators Use of Residenal, Light Commercial, Commercial, Heavy Commercial and Architectural names in rangs d e t e l e D d e t e l e D d e t e l e D d e d u l c n I d e d u l c n I Cycle/Operang Tesng for SHD Not included Not included Added Included Included Hardware Water Tesng for SHD Not included Not included Added Included Included Vercal Load Tesng for SHD Not included Not included Added Included Included FER Tesng for Swinging Doors Not included Not included Added Included Included Skylight Tesng Orientaon Not included Vercal or Sloped Vercal or Sloped Vercal or Sloped Vercal or Sloped Skylights Structural Test Load 1.4 to 3.0 mes DP in 1600/I.S.7 1.5 x DP, Pos - 2.0 x DP Neg 2.0 x DP, Pos and Neg 2.0 x DP, Pos and Neg 2.0 x DP, Pos and 1.5 x DP, Neg. Not necessary to apply a STP 100 psf higher than the rated DP Skylights Structural Test Duraon Not included Neg 10s, Pos 60s Neg & Pos 60s Neg & Pos 60s Neg & Pos 60s Specimen Structural Damage Same as previous edions Adds actuang mechanisms, disengagements Limits retests due to glass breakage or hardware to two Limits retests due to glass breakage or hardware to two Limits retests due to glass breakage or hardware to two Deglazing Sash Movement < 100% < 90% < 90% < 90% < 90% Laboratory Test Report Not included - in AAMA 103.3 Report format & Stamped dwgs Report format & Stamped dwgs Report format & Stamped dwgs Report format & Stamped dwgs Tempered Glass Can be used for tesng if it was the weakest, thinnest glass per ASTM E 1300 to qualify other glass types in producon. Can be used for tesng if it was the weakest, thinnest glass per ASTM E 1300 to qualify other glass types in producon. Can be used for tesng if it is the weakest per ASTM E 1300 and meets the L/175 requirement for edge deflecon, to qualify other glass types in producon. Can be used for tesng if it is the weakest per ASTM E 1300 and meets the L/175 requirement for edge deflecon, to qualify other glass types in producon. Can be used for tesng if it is the weakest per ASTM E 1300 and meets the L/175 requirement for edge deflecon, to qualify other glass types in producon. Transoms Not included Maximum height is 700 mm Maximum height is 800 mm Maximum height is 800 mm Maximum height is 800 mm Tubular Daylighng Device (TDD) Not included Not included Not included Added Expanded to idenfy Closed Ceiling and Open Ceiling products Water Penetraon Resistance Pressure Cap 12 psf 15 psf 12 psf 12 psf for U.S. 15 psf for Canada 12 psf for U.S. 15 psf for Canada Reference Standards: AAMA 101-93 AAMA/NWWDA 101/I.S.2-97 101/I.S.2/NAFS-02 AAMA/WDMA/CSA 101/I.S.2/A440-05 AAMA/WDMA/CSA 101/I.S.2/A440-08 AAMA/WDMA/CSA 101/I.S.2/A440-11 ® 2011 American Architectural Manufacturers Associaon--this printed or electronic page may NOT be reproduced, republished and distributed in any format without the express wrien consent of the American Architectural Manufacturers Associaon . Title: Standard/Specificaon for windows, doors, and unit skylights NAFS - North American Fenestraon Standard/Specificaon for windows, doors, and skylights AAMA Standards Comparison - Windows, Doors, and Unit Skylights Voluntary Specificaons for Aluminum and Poly (Vinyl Chloride)(PVC) Prime Windows and Glass Doors Voluntary Specificaons for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors Voluntary Performance Specificaon for Windows, Skylights and Glass Doors NAFS 2011 - North American Fenestraon Standard/Specificaon for windows, doors, and skylights 101 comparisons (97 02 05 08 11) Rev: 2 (12-01-11) page 1 of 1 Prepared by: Ken Brenden Technical Services Manager

Upload: phamkhuong

Post on 15-Jul-2018

258 views

Category:

Documents


4 download

TRANSCRIPT

Proud Member of:

Copyright® 2012

Revisions and Additional Requirements as Compared to 1997 Version

AAMA/WDMA 101/I.S.2-97 101/I.S.2/NAFS-02 AAMA/WDMA/CSA 101/I.S.2/A440-

05 AAMA/WDMA/CSA 101/I.S.2/A440-

08AAMA/WDMA/CSA 101/I.S.2/A440-11

Format Combined Combined Combined Combined Separate Sections for products, materials, and components

Basis of Rating IP Only IP Primary (Metric Optional) IP Primary (Metric Optional) IP Primary (Metric Optional) IP Primary (Metric Optional) Compliance Measurement Units IP Primary (Metric Secondary) Metric Primary (IP Secondary) Metric Primary (IP Secondary) Metric Primary (IP Secondary) Metric Primary (IP Secondary - Hard

Conversion) # of Product Operator Types 20 26 30 31 36# of Performance Classifications 5 (R, LC, C, HC, and AW) 5 (R, LC, C, HC, and AW) 5 (R, LC, C, HC, and AW) 4 (R, LC, CW, and AW) 4 (R, LC, CW, and AW)Alternative Minimum Test Size and minimum performance grades (PG) for Class R products (Clause 9)

Not Included Not included Not included Added Included

Operator Type Codes F, DA, HGD & SGD same as 93 F, DA, HGD & SGD same as 93 Chg to FW, FD, DAW, SHD & SD FW, FD, DAW, SHD & SD FW, FD, DAW, SHD & SD Performance Grade Caps No upper limit on Grade (Design

Pressure)Upper limit of 60 psf above Gateway except AW

Upper limit of 60 psf above Gateway except AW

Increased to 100 psf for R, LC, and CW classes. No limit for AW

100 psf for R, LC, and CW classes. No limit for AW

U.S. Operating Force (SGD/SD require both forces)

Force to maintain motion ONLY Force to initiate and maintain motion

Force to maintain motion but test and record force to initiate

Force to maintain motion but test and record force to initiate

Force to maintain motion but test and record force to initiate

Canadian Operating Force Not included Not included Force to maintain motion and force to initiate based on performance class

Force to maintain motion and force to initiate based on application

Force to maintain motion and force to initiate based on application

Air Leakage 0.3 and 0.1 cfm/ft2 0.3 cfm/ft2 ONLY 0.3 and 0.1 cfm/ft2 0.3 and 0.1 cfm/ft2 0.3 and 0.1 cfm/ft2 Canadian Air Leakage Not included Optional levels Optional levels Optional levels Optional levelsFrame/Sash Deflection Limits AW and HC Hung ONLY AW and HC ONLY AW and HC ONLY AW and CW ONLY AW and CW ONLYGlass Deflection Limits Exception Noted Exception Noted Exception Noted Exception Noted Exception Noted Frame/Sash Permanent Deformation 0.4% (0.2% for AW) 0.4% (0.2% for AW) 0.4% for R & LC, 0.3% for C & HC,

0.2% for AW0.4% for R & LC, 0.3% for CW, 0.2% for AW

0.4% for R & LC, 0.3% for CW, 0.2% for AW

Forced Entry Resistance Standard ASTM, CMBSO, or AAMA ASTM, CMBSO, or AAMA ASTM ONLY ASTM ONLY ASTM ONLY Force to Latch requirement (SHD) Not included Not included 65 N (15 lbf) Test and record only Test and record onlyGlass Strength Standard - basis of glass selection

ASTM E 1300-94 - use weakest glass for testing

ASTM E 1300-00 - use weakest & thinnest glass for testing

ASTM E 1300-02 - use weakest glass for testing

ASTM E 1300-02 - use weakest glass for testing

ASTM E 1300-09a - use weakest glass for testing

Hardware Lead Content Requirements Not included Not included Not included Not included Added

Parallel Opening Windows Not included Not included Not included Not included AddedPlastic Glazing Requirements No Requirements No Requirements Added 6 requirements No additional requirements No additional requirements Materials Referenced Aluminum, Wood and Vinyl Added 7 additional materials Added 2 additional materials No additional materials No additional materialsMullion Definitions and Illustrations Definition Only Examples & Illustrations Expanded Explanation Expanded Explanation Added new ratings and designations

Secondary Storm Products Not included Not included Not included Not included Added new ratings and designations

Skylights, Sidelites & Transoms Not included Added Added & Expanded Added & Expanded Added new designations for TDDs and eliminated Skylight Performance Classes.

Side-Hinged Exterior Doors Not included Not included Added Included IncludedSide-Hinged Door Systems Operation/Cycling (Clause 5.3.6.10)

Not included Not included R (25,000), LC (100,000), C (250,000), HC (except ATD-500,000), HC (ATD-25,000), AW (except ATD-1,000,000), AW (ATD-25,000)

R (25,000), LC (100,000), CW (250,000), AW (except ATD-500,000), AW (ATD-25,000)

R (25,000), LC (100,000), CW (250,000), AW (except ATD-500,000), AW (ATD-25,000)

Side-Hinged Exterior Door Glazing Exception 5 (Clause 6.2.3.4.6)

Not included Not included Not included Added - such specimens shall use the heaviest glass assembly that is to be qualified or shall have sufficient weight attached to the glazing to make it equivalent to the heaviest glazing assembly to be qualified.

Added - such specimens shall use the heaviest glass assembly that is to be qualified or shall have sufficient weight attached to the glazing to make it equivalent to the heaviest glazing assembly to be qualified.

Architectural Terrace Doors Not included Not included Added Included IncludedLimited Water Rating for SHD Not included Not included Added Included IncludedPrimary Designator (example class R casement)

C-R25 30 x 60 C-R25 760 x 1520 (30 x 60) C-R25 760 x 1520 (30 x 60) Class R-PG25: Size tested 760 × 1520 mm (30 × 60 in)-Casement

Class R-PG25: Size tested 760 × 1520 mm (30 × 60 in)-Casement

Secondary Designator Not included Not included Added AddedPrescriptive requirements identified in Clause 4.4.3.1 for the use of Secondary Designators

Prescriptive requirements identified in Clause 4.4.3.1 for the use of Secondary Designators

Use of Residential, Light Commercial, Commercial, Heavy Commercial and Architectural names in ratings

deteleDdeteleDdeteleDdedulcnIdedulcnI

Cycle/Operating Testing for SHD Not included Not included Added Included IncludedHardware Water Testing for SHD Not included Not included Added Included IncludedVertical Load Testing for SHD Not included Not included Added Included IncludedFER Testing for Swinging Doors Not included Not included Added Included IncludedSkylight Testing Orientation Not included Vertical or Sloped Vertical or Sloped Vertical or Sloped Vertical or Sloped Skylights Structural Test Load 1.4 to 3.0 times DP in 1600/I.S.7 1.5 x DP, Pos - 2.0 x DP Neg 2.0 x DP, Pos and Neg 2.0 x DP, Pos and Neg 2.0 x DP, Pos and 1.5 x DP, Neg. Not

necessary to apply a STP 100 psf higher than the rated DP

Skylights Structural Test Duration Not included Neg 10s, Pos 60s Neg & Pos 60s Neg & Pos 60s Neg & Pos 60s Specimen Structural Damage Same as previous editions Adds actuating mechanisms,

disengagements Limits retests due to glass breakage or hardware to two

Limits retests due to glass breakage or hardware to two

Limits retests due to glass breakage or hardware to two

Deglazing Sash Movement < 100% < 90% < 90% < 90% < 90% Laboratory Test Report Not included - in AAMA 103.3 Report format & Stamped dwgs Report format & Stamped dwgs Report format & Stamped dwgs Report format & Stamped dwgs

Tempered Glass Can be used for testing if it was the weakest, thinnest glass per ASTM E 1300 to qualify other glass types in production.

Can be used for testing if it was the weakest, thinnest glass per ASTM E 1300 to qualify other glass types in production.

Can be used for testing if it is the weakest per ASTM E 1300 and meets the L/175 requirement for edge deflection, to qualify other glass types in production.

Can be used for testing if it is the weakest per ASTM E 1300 and meets the L/175 requirement for edge deflection, to qualify other glass types in production.

Can be used for testing if it is the weakest per ASTM E 1300 and meets the L/175 requirement for edge deflection, to qualify other glass types in production.

Transoms Not included Maximum height is 700 mm Maximum height is 800 mm Maximum height is 800 mm Maximum height is 800 mm Tubular Daylighting Device (TDD) Not included Not included Not included Added Expanded to identify Closed Ceiling

and Open Ceiling productsWater Penetration Resistance Pressure Cap

12 psf 15 psf 12 psf 12 psf for U.S.15 psf for Canada

12 psf for U.S.15 psf for Canada

Reference Standards:

AAMA 101-93 AAMA/NWWDA 101/I.S.2-97 101/I.S.2/NAFS-02 AAMA/WDMA/CSA 101/I.S.2/A440-05 AAMA/WDMA/CSA 101/I.S.2/A440-08 AAMA/WDMA/CSA 101/I.S.2/A440-11

® 2011 American Architectural Manufacturers Association--this printed or electronic page may NOT be reproduced, republished and distributed in any format without the express written consent of the American Architectural Manufacturers Association .

Title:

Standard/Specification for windows, doors, and unit skylightsNAFS - North American Fenestration Standard/Specification for windows, doors, and skylights

AAMA Standards Comparison - Windows, Doors, and Unit Skylights

Voluntary Specifications for Aluminum and Poly (Vinyl Chloride)(PVC) Prime Windows and Glass Doors Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors Voluntary Performance Specification for Windows, Skylights and Glass Doors

NAFS 2011 - North American Fenestration Standard/Specification for windows, doors, and skylights

101 comparisons (97 02 05 08 11)Rev: 2 (12-01-11) page 1 of 1

Prepared by: Ken BrendenTechnical Services Manager