ablerex is power converter ares rt series specifications · 3:1 pure sine wave battery *...

1
Ares RT Series DSP-Controlled On-Line UPS ARES RT 1KVA~3KVA True On-line Double Conversion Topology Advanced DSP Control Technology 0.9 Output Power Factor Rack/Tower Design Wide Input Voltage Range Active Harmonic Current Control LCD/LED Display Patent Backup Runtime Estimation Multiple Operation Mode Supported Remote Emergency Power Off (REPO) Programmable Outlets Easy Firmware Flash Upgrade Ablerex is Power ConverterSingle Phase UPS Specifications 1920 Display Alarm Protection Function Physical Environmental Interface Standards and Certifications**** Model ARES RT 3000 ARES RT 1000 ARES RT 1500 ARES RT 2200 ARES RT 1000 ARES RT 2000 ARES RT 3000 Phase Voltage Range** Frequency Range Input Power Factor Capacity Output Voltage Output Power Factor*** Output Voltage Distortion Output Voltage Regulation Frequency Range Crest Factor Output Waveform Line Mode High Efficiency Mode Battery Type Battery Number Battery Voltage Recharge Time (to 90%) LED LCD measures Self-Diagnostics Audible or Visual Full Protection Multi-Mode DC start Programmable Outlet Dimensions (WxHxD, mm/inch) Net Weight (kg/lbs) Operation Temperature Operation Humidity Altitude Noise Level Standard Option Compatible Platforms Safety EMC Marks Input Output Efficiency 110~300Vac 45~60Hz / 50~70Hz (Auto sensing) 0.99 @ Full Load 208/220/230/240 Vac Up to 92% Up to 96% 55~150 Vac 45-70Hz >0.98@ 100% linear load 100/110/115/120/127 Vac >90% >96% 0.9 <3% @ 100% Linear load <7% @ 100% non-linear load ±1% ±1Hz or ±3Hz (Selectable ) 3:1 Pure Sine Wave Battery * Specifications subject to change without notice. ** Based on load percentage. *** Depending on the model and voltage, please contact Ablerex for more information. **** The same technical specification may be sold in different countries under different model names, please consult Ablerex for more information. Contents BC120240 BC120360 BC080480 BC120720 BC080960 Battery Bank Specifications Rated Battery Voltage Number of batteries Battery type Dimensions (WxHxD,mm/inch) Charging Capability 24 8 36 12 48 8 Lead Acid Maintenance Free 12V 7Ah/9Ah 440x88x650 / 17.3x3.5x25.6 Optional Universal 200W Charger 72 12 96 8 1000VA/900W 2000VA/1800W 3000VA/2700W 1000VA/900W 1500VA/1350W 2200VA/1980W 3000VA/2700W 2 24 3 36 4 48 6 72 6 72 8 96 2 24 3 36 4 48 6 72 440x88x390 17.3x3.5x15.4 88 x 440 x 405 17.3x3.5x16.0 440x88x475 17.3x3.5x17.8 440x88x600 17.3x3.5x23.7 440x88x600 17.3x3.5x23.7 440x88x695 17.3x3.5x23.7 12/26.4 14.5/31.9 17/37.4 21.5/47.4 26.5/58.4 31.5/69.4 11/24.2 14.5/32 20/44 27/59.5 88 x 440 x 390 17.3x3.5x15.4 88 x 440 x 405 17.3x3.5x16.0 88 x 440 x 475 17.3x3.5x17.8 88 x 440 x 600 17.3x3.5x23.7 www.ablerex.com.tw 0~40°C / 32~104°F 20%~95%RH (Without condensing) 1000m/3280ft without Derating 50dBA @ 1 meter front Dry Contact Relay, SNMP/WEB Card Microsoft Windows series, Linux, Mac, etc. Sealed Lead Acid Maintenance Free 12Vdc Volatge / Frequency / Load level / Battery level Upon Power-on, Front Panel Setting & Software Control, 24 hours routine check Line Failure / Battery Low / Transfer to Bypass / System Fault Overload, Over temperature, Short circuit, Discharge, overcharge Normal/ ECO/ CVCF Yes Option Load Level/Battery Level/ Battery Mode/ Normal Mode/Bypass Mode/ Self-Test/Weak/ Bad Battery/ Site Wiring Fault/ Fault/ OverloadOutput status/Programmable Outlet1/ Programmable Outlet2 Single Phase with Ground UL1778 FCC Class A UL, cUL, FCC ENG62040-1 ENG62040-2, EN61000-3-3 CE ARES RT 1KVA & ARES RT 2KVA ARES RT 3KVA 4 hours RS-232, USB, EPO RS-232

Upload: others

Post on 23-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ablerex is Power Converter Ares RT Series Specifications · 3:1 Pure Sine Wave Battery * Specifications subject to change without notice. ** Based on load percentage. *** Depending

Ares RT SeriesDSP-Controlled On-Line UPSARES RT 1KVA~3KVA

■ True On-line Double Conversion Topology

■ Advanced DSP Control Technology

■ 0.9 Output Power Factor

■ Rack/Tower Design

■ Wide Input Voltage Range

■ Active Harmonic Current Control

■ LCD/LED Display

■ Patent Backup Runtime Estimation

■ Multiple Operation Mode Supported

■ Remote Emergency Power Off (REPO)

■ Programmable Outlets

■ Easy Firmware Flash Upgrade

Ablerex is Power Converter|Single Phase UPS

Specifications

19|20

Display

AlarmProtection

Function

Physical

Environmental

Interface

Standards and Certifications****

Model ARES RT 3000ARES RT 1000 ARES RT 1500 ARES RT 2200ARES RT 1000 ARES RT 2000 ARES RT 3000

Phase

Voltage Range**

Frequency Range

Input Power Factor

Capacity

Output Voltage

Output Power Factor***

Output Voltage Distortion

Output Voltage Regulation

Frequency Range

Crest Factor

Output Waveform

Line Mode

High Efficiency Mode

Battery Type

Battery Number

Battery Voltage

Recharge Time (to 90%)

LED

LCD measuresSelf-Diagnostics

Audible or Visual

Full Protection

Multi-Mode

DC start

Programmable Outlet

Dimensions

(WxHxD, mm/inch)

Net Weight (kg/lbs)

Operation Temperature

Operation Humidity

Altitude

Noise Level

Standard

Option

Compatible Platforms

Safety

EMC

Marks

Input

Output

Efficiency

110~300Vac

45~60Hz / 50~70Hz (Auto sensing)

≧0.99 @ Full Load

208/220/230/240 Vac

Up to 92%

Up to 96%

55~150 Vac

45-70Hz

>0.98@ 100% linear load

100/110/115/120/127 Vac

>90%

>96%

0.9

<3% @ 100% Linear load <7% @ 100% non-linear load

±1%

±1Hz or ±3Hz (Selectable )

3:1

Pure Sine Wave

Battery

* Specifications subject to change without notice.** Based on load percentage.*** Depending on the model and voltage, please contact Ablerex for more information.**** The same technical specification may be sold in different countries under different model names,

please consult Ablerex for more information.

Contents BC120240 BC120360 BC080480 BC120720 BC080960Battery Bank Specifications

Rated Battery VoltageNumber of batteriesBattery typeDimensions (WxHxD,mm/inch)

Charging Capability

248

3612

488

Lead Acid Maintenance Free 12V 7Ah/9Ah440x88x650 / 17.3x3.5x25.6

Optional Universal 200W Charger

7212

968

1000VA/900W 2000VA/1800W 3000VA/2700W 1000VA/900W 1500VA/1350W 2200VA/1980W 3000VA/2700W

2

24

3

36

4

48

6

72

6

72

8

96

2

24

3

36

4

48

6

72

440x88x390

17.3x3.5x15.4

88 x 440 x 405

17.3x3.5x16.0

440x88x475

17.3x3.5x17.8

440x88x600

17.3x3.5x23.7

440x88x600

17.3x3.5x23.7

440x88x695

17.3x3.5x23.7

12/26.4 14.5/31.9 17/37.4 21.5/47.4 26.5/58.4 31.5/69.4 11/24.2 14.5/32 20/44 27/59.5

88 x 440 x 390

17.3x3.5x15.4

88 x 440 x 405

17.3x3.5x16.0

88 x 440 x 475

17.3x3.5x17.8

88 x 440 x 600

17.3x3.5x23.7

www.ablerex.com.tw

0~40°C / 32~104°F

20%~95%RH (Without condensing)

1000m/3280ft without Derating

≦50dBA @ 1 meter front

Dry Contact Relay, SNMP/WEB Card

Microsoft Windows series, Linux, Mac, etc.

Sealed Lead Acid Maintenance Free 12Vdc

Volatge / Frequency / Load level / Battery levelUpon Power-on, Front Panel Setting & Software Control, 24 hours routine check

Line Failure / Battery Low / Transfer to Bypass / System Fault

Overload, Over temperature, Short circuit, Discharge, overcharge

Normal/ ECO/ CVCF

Yes

Option

Load Level/Battery Level/ Battery Mode/ Normal Mode/Bypass Mode/ Self-Test/Weak/ Bad Battery/Site Wiring Fault/ Fault/ OverloadOutput status/Programmable Outlet1/ Programmable Outlet2

Single Phase with Ground

UL1778

FCC Class A

UL, cUL, FCC

ENG62040-1

ENG62040-2, EN61000-3-3

CE

■ ARES RT 1KVA & ARES RT 2KVA ■ ARES RT 3KVA

4 hours

RS-232, USB, EPORS-232