About SCAF Module PHILOSEP SCAF Module is designed to treat water. Membranes are washed and recovered efficiently with Aeration from the bottom and periodical Back-wash at the same time. The UF Membranes are physically firm since they are made with Polyethersulfone (PES) and they have a symmetric sponge structure. . The membranes have active layers with very even pores on the surfaces that are optimized for Outside-In filtration. Simultaneous execution of Back-wash and CEB efficiently eliminates particle matters and organic contaminants attached to membrane surfaces. SCAF Operation Scheme SCAF UF Hollow Fiber Membrane Module for Water Treatment

Upload: deana

Post on 23-Feb-2016

57 views

Category:

Documents


0 download

DESCRIPTION

SCAF. UF Hollow Fiber Membrane Module for Water Treatment. About SCAF Module. PHILOSEP SCAF Module is designed to treat water. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: About SCAF Module

About SCAF ModulePHILOSEP SCAF Module is designed to treat water.

Membranes are washed and recovered efficiently with Aeration from the bottom and periodical Back-wash at

the same time. The UF Membranes are physically firm since they are made with Polyethersulfone (PES) and

they have a symmetric sponge structure. .

The membranes have active layers with

very even pores on the surfaces that

are optimized for Outside-In filtration.

Simultaneous execution of Back-wash

and CEB efficiently eliminates particle

matters and organic contaminants at-

tached to membrane surfaces.

SCAF Operation Scheme

SCAFUF Hollow Fiber Membrane Module for Water Treatment

Page 2: About SCAF Module

Applications of SCAF Modules Industrial Water Treatment Pretreatment of RO Ultrapure Water Manufacturing

Pre-treatment Water Reuse Wastewater Treatment Village Water Supply

Contaminant-resist Hydrophilic PES

Stable and Constant Flow rate

High physical Strength with the Sponge structure

Excellent Heat-resistance

Excellent Chemical-resistance (pH 2~12)

Features of PES Hollow Fiber Membranes

SCAF Flow diagram

Excellent stability of the Flow rate and Filtered Water QualityHydrophilic PES membranes in PHILOSEP SCAF modules have very even pores. They are used in water treatment or pure water manufacturing process where the stable water quality is necessity. Applied to Filter High Turbidity LiquidSimultaneous execution of Back-wash and CEB efficiently eliminates particle matters and organic contaminants attached to membrane surfaces. This feature makes it pos-sible for the modules to be applied to filter high turbidity drain water. Stable Supply of Filtered Water Repeating filtering and Back-washing supplies water to RO system more stably com-pare to Media filtering which has to be paused for a long time for a Back- wash.

Features of SCAF Modules

Page 3: About SCAF Module

Item SCAF 6

Performance

Filtration Capacity

Filterer Water SDI

 

5.3 ~ 13.2 GPM (1.2 ~ 3.0 m3/hr )

< 3 (When Turbidity of Drain Water<15 NTU)

Membrane

Materials

MWCO

Area

 

Polyethersulfone (PES)

150,000 Daltons

323 ft2 (30 m2)

Operation Data

Designed Flux

Max. Inlet Pressure

Normal Operation Pressure

Max. Operation Pressure

Max. Inlet Turbidity

Max. Operation Temperature

Air Injection

Dead end Filtration

Cross Flow Filtration

pH range

20 ~ 50 GFD (40 ~ 100 L/m2·h)

43.5 psig (3 kg/cm2)

4 ~ 14.7 psig (0.3 ~ 1.0 kg/cm2)

< 22 psig (1.5 kg/cm2)

30 NTU

104 (40 )℉ ℃80~160L/min•module

< 15 NTU

> 15 NTU

2.0 ~ 12.0

Module Size

Module Weight (When Dry)

Φ6 inch x L70 inch

18kg

SCAF Module Specification