absolute filters for iso5011-layout 1filteq.com/images/absolute_filters_for_iso5011.pdfnew absolute...

4
air- inlet air- outlet when door is opened, sealing gasket is released -> filter can easily be taken out of the housing New Absolute Filter for Test Benches According to ISO 5011 for Inlet Air Cleaning Equipment for Internal Combustion Engines and Compressors (replaces plane round filters) - two versions for flow ranges up to 20 or up to 30 m 3 /min -> quick mounting and removal of filter (approx. 90 % time saving) -> no dismounting of test bench for weighing of absolute filter -> handling from both sides -> saving costs through multiple usage of absolute filter -> low tara of filter cartridge (approx. 600 g) for exact weighing FilTEq Filtration Testing Equipment & Services GmbH www.filteq.com Amthausstr. 14 Tel.: +49-(0)721-406544 [email protected] D-76227 Karlsruhe Fax: +49-(0)721-406545 *FILTER TESTING*DATA ACQUISITION*GAS CLEANING*POWDER HANDLING and DISPERSING*

Upload: others

Post on 24-Jan-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: absolute filters for ISO5011-Layout 1filteq.com/images/absolute_filters_for_ISO5011.pdfNew Absolute Filter for Test Benches According to ISO 5011 for Inlet Air Cleaning Equipment for

air- inlet

air- outlet

when door is opened, sealing gasket is released -> filter can easily be taken out of the housing

New Absolute Filter for Test Benches According to ISO 5011for Inlet Air Cleaning Equipment for Internal CombustionEngines and Compressors (replaces plane round filters)

- two versions for flow ranges up to 20 or up to 30 m3/min -> quick mounting and removal of filter (approx. 90 % time saving) -> no dismounting of test bench for weighing of absolute filter -> handling from both sides -> saving costs through multiple usage of absolute filter -> low tara of filter cartridge (approx. 600 g) for exact weighing

FilTEqFiltration Testing Equipment & Services GmbH

www.filteq.com Amthausstr. 14 Tel.: +49-(0)[email protected] D-76227 Karlsruhe Fax: +49-(0)721-406545

*FILTER TESTING*DATA ACQUISITION*GAS CLEANING*POWDER HANDLING and DISPERSING*

Page 2: absolute filters for ISO5011-Layout 1filteq.com/images/absolute_filters_for_ISO5011.pdfNew Absolute Filter for Test Benches According to ISO 5011 for Inlet Air Cleaning Equipment for

by closing the door, seal gasket of filter cartridge is tightened automatically

seal for filter frame

axial skid

bracket for pressing of the filter frame - closed

bracket for pressing on the frame of filter cartridge - filter can be removed for weighing when opened

Page 3: absolute filters for ISO5011-Layout 1filteq.com/images/absolute_filters_for_ISO5011.pdfNew Absolute Filter for Test Benches According to ISO 5011 for Inlet Air Cleaning Equipment for

two handle for easy opening from both sides

Ring line for differential pressure measurement

spring bolt improved guidance to slide in filter (on both sides)

skid is moved to release seals by springs when door is opened

clamping door lock to tighten door seals (hight adjustable)

gas flow in

bracket for pressing on frame of filter cartridge

Page 4: absolute filters for ISO5011-Layout 1filteq.com/images/absolute_filters_for_ISO5011.pdfNew Absolute Filter for Test Benches According to ISO 5011 for Inlet Air Cleaning Equipment for

gas filled damper to prevent falling shut of door (safety device)

connectors for pressure drop measurement

bracket to seal filter cartridge and ring line with 4 openings for pres- sure drop measurement

socket for proximity switch to

prevent start of blower when door is open

proximity switch

improved guidance to slide in filter (on both sides)