acc safety report

11
1 AMS AMS - - 02: 02: Anti Anti Coincidence Coincidence Counter Counter ACC ACC Th. Kirn The ACC surrounds the silicon tracker inside the magnet. It rejects particles that leave or enter AMS-02 through inner shell of the magnet protection against misidentification of matter nuclei as antimatter nuclei. Requirements: High detection efficiency (0.9999) operational in high magnetic field fast response for trigger

Upload: hathu

Post on 28-Dec-2016

226 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ACC Safety Report

Th. Kirn Anticoincidence Counter ACC 1

AMSAMS--02: 02: AntiAnti CoincidenceCoincidence CounterCounter ACCACC

Th. Kirn

The ACC surrounds the silicon tracker inside the magnet. It rejects particles that leave or enter AMS-02 through inner shell of the magnet → protection against misidentification of matter nuclei as antimatter nuclei.

Requirements:• High detection efficiency (0.9999)• operational in high magnetic field• fast response for trigger

Page 2: ACC Safety Report

Th. Kirn Anticoincidence Counter ACC 2

AMSAMS--02: 02: AntiAnti CoincidenceCoincidence CounterCounter ACCACC

ACC ACC

Rejection of internal events Rejection of external events

Page 3: ACC Safety Report

Th. Kirn Anticoincidence Counter ACC 3

Scintillator Panel: Bicron BC414 (826.5 x 230 x 8 mm³)Wavelength Shifting Fiber (WLS): Kuraray Y-11(200)MClear Fiber (CLF): Toray PJU-FB1000Photomultiplier (PMT): Hamamatsu R5946

ACC Principle

PMT

WLS fiber Clear fiber

Charged particleCoupling

PMT

WLS fiberClear fiber

Coupling

Scintillator

Page 4: ACC Safety Report

Th. Kirn Anticoincidence Counter ACC 4

Panel: Bicron BC414 WLS: Kuraray Y-11(200)MCLF: Toray PJU-FB1000PMT: Hamamatsu R5946

ACC System

Page 5: ACC Safety Report

Th. Kirn Anticoincidence Counter ACC 5

AMS-01 ACC, ETH Zürich, July 1997

Panel: Bicron BC414 WLS-Fibers: Kuraray Y-11(200)MVibration tests and TVT testsperformed for AMS-01 (STS-91)

Page 6: ACC Safety Report

Th. Kirn Anticoincidence Counter ACC 6

ACC Scintillation panel

Page 7: ACC Safety Report

Th. Kirn Anticoincidence Counter ACC 7

machining (grooves):

all (16+4) done

ACC Scintillaton Panel machining

Page 8: ACC Safety Report

Th. Kirn Anticoincidence Counter ACC 8

ACC Scintillation Panel ProductionMachining of panel

Curing of glueWLS → Panel

Fiber Bending Protection & Viton Tube & UV-LED

Wrapping & Optical Coupling

Final Scintillation Panel

All (16+4) done

Page 9: ACC Safety Report

Th. Kirn Anticoincidence Counter ACC 9

Clear Fiber ↔ PMT

ACC Optical Couplings: WLS Fiber ↔ Clear Fiber ↔ PMT

WLS ↔ Clear Fiber

Clear Fiber Cable

Page 10: ACC Safety Report

Th. Kirn Anticoincidence Counter ACC 10

ACC PMT: Hamamatsu R5946

Page 11: ACC Safety Report

Th. Kirn Anticoincidence Counter ACC 11

Vibration Testing and Thermal Vacuum Testingare ongoing

ACC PMT: 4 Hamamatsu R5946 in Box