accessories handbook 2013 - apel laser · accessories handbook 3 contents 1 control electronics...

20
Accessories Handbook Unlimited possibilities. valid from 2013 for NanoWizard ® , ForceRobot ® and CellHesion ® systems

Upload: others

Post on 06-Jul-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

Accessories Handbook

Unlimited possibilities.

valid from 2013

for NanoWizard®, ForceRobot® and CellHesion® systems

Page 2: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

The NanoWizard®, ForceRobot® and CellHesion® family

Optional headsCellHesion® 200CellHesion® 200 ForceRobot® 300ForceRobot® 300

Head

Software SPM COntrOl & DAtA PrOCeSSing QI™ Advanced

Manipulation & lithography

Experiment Planner™

Advanced Force

Spectroscopy

Direct Overlay™SPM Control & DAtA ProCeSSing

Stages Motorized precision stage life sciences stage Standard stage HCS™

Heating cooling stage

ECCell™ – Electrochemisty cell

temperature control

PetriDishHeater™ CoverslipHolderBioCell™ eCCell™ Electrochemistry cell

HCM™ Heating cooling module

HtHS™ High temperature

heating stage

Typical BioScience applications and research fields:

High resolution imaging in air and liquid of single molecules such as proteins, DNA/RNA, carbohydrates, lipids, Live Cell Imaging, bacteria and virus characterization, cellular adhesion and cytomechanics, molecular interactions, receptor-ligand, antibody-antigen, molecular unfolding, molecular recognition, biomaterials, compound and implant characterization, material properties such as adhesion, elasticity, hardness; drug formulation, encapsulation and aging studies and many more

Setups and accessories for BioScience applications highlighted with ligHt BlUe BOXeS

Typical NanoScience applications and research fields:

High resolution imaging in air and liquid of single molecules, thin films, nanoparticles or nanowires, surface properties characterization such as adhesion, stiffness, friction, conductivity, charges, hardness; polymer science, single molecule force measurements, smart organic materials, surface properties of conjugated polymers, biosensors, degradable materials, electrochemistry, colloidal probe, surface forces and interface phenomena; and many more

Setups and accessories for nanoScience applications highlighted with grAY BOXeS

For more detailed information about all options see the brochures and product notes or visit www.jpk.com.

Control electronics options

SignAl ACCeSS MODUle (SAM)Signal acceSS Module (SaM)

Vortis™ SPMControlVortis™ SPMControlVortis™ Advanced

SPMControlSPMControl

2

NanoWizard® 3NanoWizard® 3NanoScience and BioScience versions

NanoWizard® 3NanoWizard® 3NanoOptics fiber port and UV transparency versions

electrical modes & application modules

High Voltage Sample Bias Amplifier

Conductive AFM

module

tuning fork

module

CoverslipHolder with electrical

sample connection

HyperDrive™ fluid imaging

package

Kelvin Probe

module

StM module

extras & OeM 8x FluidicsModule™

Acoustic enclosure

Vibration isolation

Fiber coupled detection module

Base frame for ac- tive isolation tables Cameras

Fluid cells & cantilever holders

Small volume SmallCell™

Standard CantileverHolder

Magnetic field CantileverHolder

Side-view CantileverHolder

CantileverHolder with electrical tip connection

Supercut CantileverHolderSmallCell™

BioMAT™ CellHesion® Module

System options

PetriDishHeater™ for BioMAT™

TopView Optics™

TAO™

Module

2-axes3-axes

Page 3: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

Accessories Handbook

3

Contents

1 Control electronics options 4

Vortis™ SPMControl Station Vortis™ Advanced SPMControl Station Signal Access Module (SAM)

2 System options 5

NanoWizard® 3 NanoOptics version head ForceRobot® 300 CellHesion® 200 TAO™ Tip Assisted Optics module BioMaterials Workstation BioMAT™ CellHesion® module

3 Software modules 7

DirectOverlay™ module NanoLithography/NanoManipulation module Advanced Force Spectroscopy module QI™ Advanced software module ExperimentPlanner™ software module

4 Applications modules and modes 8

HyperDrive™ fluid imaging package Electrical sample connection module CoverslipHolder with electrical sample connection Kelvin Probe (KPM) and Scanning Capacitance (SCM)

Microscopy module Conductive AFM module Conductive AFM module – Enclosed Volume Scanning Tunnelling Microscopy (STM) module Tuning Fork module High Voltage Sample Bias Amplifier ForceWheel™

5 Sample stages 10

Motorized precision stage Manual precision stage Sample holder for large samples Standard stage

6 Cantilever holder options 11

Standard cantilever holder Supercut version cantilever holder Cantilever holder with electrical tip connection Side-view cantilever holder Magnetic field cantilever holder

7 Environmental control options – fluid cells and temperature controls 12

BioCell™ CoverslipHolder PetriDishHeater™ PetriDishHeater™ for BioMAT™ SmallCell™ 3-port small volume SmallCell™ High Temperature Heating Stage (HTHS™) Heating Cooling Module (HCM™) Heating Cooling Stage (HCS™)

8 Electrochemistry solutions 14

Temperature controlled ECCell™ Heating Cooling Stage (HCS™) with electrochemistry cell OEM Potentiostats from eDAQ

9 Vibration and acoustic isolation 15

Active vibration isolation from Accurion Active vibration isolation from Table Stable Active air damping tables from TMC JPK acoustic enclosure JPK base for acoustic enclosure

10 Optics accessories 16

TopViewOptics™ TopViewOptics™ with boom stand TopViewOptics™ for use with inverted optical microscopes

or the JPK BioMAT™ Raman reflector kit Upright Fluorescence Microscope (UFM) Kit Fiber coupled detection module Inverted optical microscope configurations

11 OEM solutions and small parts 17

JPK sample holder for small samples JPK cable anchorage pillow JPK cantilever changing tool JPK biocompatible glue JPK spare parts OEM syringe pumps JPK 8x FluidicsModule™ AFM cantilevers, substrates and standards CCD cameras OEM Scanning Thermal AFM from Anasys OEM Indentation solutions OEM incubators for Live Cell experiments under

controlled environments OEM glove box system for NanoWizard® AFMs

Page 4: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

Control electronics options1

Vortis™ SPMControl StationState-of-the-art digital controller with lowest noise levels.

Vortis™ Advanced SPMControl StationThe most advanced SPM controller. (see product note)

Key features

High speed 16bit AD conversion with 60 MHz for the photodetector signals 24 bit ultra precise ADC with 2.5 MHz High speed lock-in amplifier technology for

precise amplitude and phase detection High speed data capture with optional

burst mode

Modular hybrid analog/digital design with latest FPGA/PPC technology (PowerPC @ 660 MHz/FPGAs @ 240 MHz) Gigabit Ethernet interface for fast data link Number of data points that can be captured

continuously: restricted only by HDD Thermal noise acquisition up to 3.25 MHz

Key features

State-of-the-art digital controller with lowest noise levels and highest number of signal channels 4 high speed 16 bit ADC channels with 60 MHz 12 ADCs with 18 bit with 800 kHz 24 bit ultra precise ADC with 2.5 MHz 3 channels 14 bit DAC with 120 MHz 8 channels 24 bit DAC with 400 kHz 2 high-speed and 1 mid-speed lock-in amplifiers

for precise amplitude and phase detection

High speed data capture Modular hybrid analog/digital design with latest

FPGA/PPC technology (PowerPC @ 660 MHz / FPGAs @ 240 MHz) Gigabit Ethernet interface for fast data link Number of data points that can be captured

continuously: restricted only by HDD Thermal noise acquisition up to 3.25 MHz 2 gated photon counters

Signal Access Module (SAM)Upgrade for the Vortis™ controller for more flexibility.

Key features

Analog and digital connectors for maximum experimental freedom Analog inputs: 27; analog outputs: 23

Digital inputs: 8 + 2 channels for, e.g., photon counting Digital outputs: 10 + 2

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

4

Page 5: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

System options2

ForceRobot® 300The innovative force spectroscope with fully automated work flow. Take more than 80,000 force curves within 24 h while varying parameters such as temperature or loading rate. (see ForceRobot® 300 brochure)

Key features

Fully automated force spectroscope with highest flexibility Cutting edge force spectroscopy and force mapping

in combination with single molecule fluorescence Automated laser and detector alignment

Automated cantilever drift compensation Advanced and dedicated software with

ExperimentPlanner™, RampDesigner™ and built-in data batch processing Fits to the Vortis™ controller

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

CellHesion® 200The single cell force testing solution for cell adhesion and elasticity studies. Specialized platform for cell adhesion and cell mechanics measurements from single molecules to entire cells. (see CellHesion® 200 brochure)

Key features

Cantilever sensor lifting system with >110 µm travel range with closed-loop control through high-speed capacitive sensor feedback

Integrates with advanced optical imaging (DIC, CLSM, TIRF, FRET...) Fits to the Vortis™ controller

5

NanoWizard® 3 NanoOptics head in two versions: with fiber port for fiber SNOM experiments UV transparency for top/down illumination

The new NanoWizard® 3 NanoOptics AFM head is optimized for a broad range of applications ranging from nanoscale optical imaging by aperture and scattering-type SNOM to experiments involving interactions of light with the sample such as absorption, excitation, nonlinear effects and quenching. (see NanoWizard® 3 NanoOptics brochure)

Key features

Comprehensive solutions for AFM and Raman spectroscopy, Tip-Enhanced Raman Spectroscopy (TERS), Aperture SNOM and Scattering-type SNOM (sSNOM), Confocal microscopy, NanoManipulation in optical fields Compatible with most commercially available

inverted research microscopes (Zeiss Axiovert and Axio Observer lines, Nikon TE and Ti lines, Olympus IX line and Leica DMI line)

Unique integration with optical microscopy by tip and sample scanning design, DirectOverlay™ mode and smart engineering Seamless integration with inverted microscopes,

Raman spectrometers, photon counting systems 980 nm laser source for cantilever deflection

detection prevents cross talk with other wavelengths Wide range of operation modes and accessories

such as Tuning Fork, STM, Conductive AFM, Fiber SNOM

Page 6: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

6

TAO™ Tip Assisted Optics moduleSpecialized sample stage for advanced experiments combining AFM and optical spectroscopy based on proven NanoWizard® technology. 2 axis and 3 axis version available. (see TAO™ module product note)

Key features

Ultimate platform for TERS, scatter type SNOM, single molecule imaging/spectroscopy experiments NanoOptical studies such as quenching, field

enhancement or bleaching Integrated sample scanning confocal imaging Integrates with conventional and advanced optical

imaging (DIC, Phase contrast, CLSM, TIRF, FRET...)

Ultimate flexibility through simultaneous control of up to 6 scan axes with closed loop precision (linearized with capacitive sensors): AFM tip scanner: 100 × 100 × 15 µm3 Sample scanner:

100 × 100 × 10 µm3

100 × 100 µm2 30 × 30 × 10 µm3 Flexible software system solution for experimental

freedom and remote operation Fits to the Vortis™ Advanced controller

BioMaterials Workstation BioMAT™

Completely integrated system comprising upright optical microscope and AFM. The specialist for investigations of opaque samples in life and material sciences. (see BioMAT™ brochure)

Key features

Studies on non-transparent substrates or samples with AFM and optics Outstanding reproducibility of the focussed

position (ROI) with both systems Unique capability to investigate the ROI precisely

with optics and AFM Also perfect during operation in liquids

Wide range of applications: Biochips, cell chips or patterned substrates for cell adhesion, plant cell applications, microbiology, tissue engineering, ... Flexible concept with shuttle stage Both techniques can be operated even in different

laboratory rooms

CellHesion® moduleAs an add-on to the NanoWizard®, the CellHesion® module combines the capabilities of the BioAFM with precise adhesion force measurements and all optical microscopy features simultaneously. (see CellHesion® module product note)

Key features

100 µm additional z-travel Perfect hardware linearization through

capacitive sensors

Simultaneous focus tracking optional Integrates with advanced optical imaging

(DIC, Confocal microscopy, TIRF, FRET...)

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

Page 7: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

Software modules3

7

350nm

DirectOverlay™ modulePerfect integration of optical and AFM data – JPK‘s proprietary and patented solution for perfect overlay of optical and AFM information.

Key features

Perfect overlay of optical and AFM data with sub-diffraction limit precision Direct “in optical image” selection of AFM

measurements (imaging and force curves) Dramatic reduction of overview image scanning in

AFM, giving faster results & lower tip contamination

Optical image navigation to specific regions of interest, even without AFM scanning. This protects functionalized tips for molecular recognition, avoiding tip passivation from image scanning before the force measurements.

NanoLithography/NanoManipulation moduleSoftware module for NanoWizard® systems.

Advanced Force Spectroscopy moduleFor advanced force measurement experiments from single protein unfolding, DNA stretching to probing of cells and tissue.

Key features

Free-hand or vector-based patterns are possible Moving objects or scratching the substrate with

controlled force are possible

Pattern creation by electrical current such as anodic oxidation

Key features

Integrated RampDesigner™ for user defined segmentation of force curves

Advanced force clamp

Tuneable frequency sweep from 0.1 to 10 kHz Setting of user-defined patterns for rheology

applications

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

QI™ Advanced software moduleQI™ Advanced Software module for NanoWizard® systems delivers quantitative mechanical properties. (see QI™ brochure)

Key features

Any kind of sample can be imaged: samples with steep edges, loosely attached samples, soft, sticky and brittle samples Works under ambient conditions and in fluid Quick to learn and easy to operate Provides additionally adhesion, stiffness and

dissipation data while scanning

Depending on application, it can also deliver electrical conductivity or molecular recognition in a single scan Contact Point Imaging (CPI) mode for extremely

soft and inhomogeneous surfaces QI™ Advanced imaging mode for conductive measu-

rements in combination with the JPK CAFM module

Page 8: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

Applications modules and modes

Electrical sample connection module

Key features

Accommodates electrical conductive samples such as AFM metal stubs by magnetic fixation or transparent samples such as ITO coated glass coverslips Insert for Life Science stages

CoverslipHolder with electrical sample connectionFor electrical measurements such as Conductive AFM or STM on a coverslip in combination with high NA optics.

Key features

Accommodates electrical conductive samples and transparent samples such as ITO coated glass coverslips Insert for Life Science stages

HyperDrive™ fluid imaging package For highest resolution imaging of small structured samples in liquid. (see jpk website for more information)

Key features

Optional for Nanowizard® 3 Nanoscience and Bioscience version Minimized tip-sample interaction by using smallest amplitudes Consists of a special cantilever holder with direct drive functionality, and a control software module

Kelvin Probe (KPM) and Scanning Capacitance (SCM) Microscopy moduleOption for nanoscale mapping of surface potential distribution.

Key features

Surface Potential Mapping Electrical tip connection

External bias electronics module (+/-10 V) Software interface

4

8

ExperimentPlanner™ software moduleFor comprehensive planning of an experiment with all of the external parameters.

Key features

Delivers full control over all system options Design of advanced experiments

Scanners, motors, light sources, detectors, environmental control options etc can be master controlled and timed

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

Page 9: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

Scanning Tunnelling Microscopy (STM) moduleThe STM module fits directly to the NanoWizard® head.

Key features

The module can accommodate different STM probes Is compatible to the JPK electrical sample connection module

Compatible with the JPK TopViewOptics™ for controlled tip positioning

Tuning Fork moduleThe Tuning Fork module fits directly to the NanoWizard® head.

Key features

Works with self excitation or external mechanical dither Allows vertical (shear force) or horizontal mounting of

tuning forks

Includes two holder boards and two unpackaged 40 kHz tuning forks for self assembly

Conductive AFM module – Enclosed VolumeFor experiments in inert atmosphere; for conductivity and I/V measurements on the nanoscale under controlled environmental conditions.

Key features

High-performance conductive AFM experiments under user defined gas atmosphere Recording I/V curves Bias voltage range ± 10 V

Noise limit 0.55 pA RMS Sample holders for opaque samples Sample holder for transparent samples

works with all optical microscopes

ForceWheel™JPK‘s ForceWheel™ handheld accessory for most sensitive experiment control, e.g., for force spectroscopy.

Key features

Connected via USB Manual force curve acquisition Continuous setting of gains and setpoints

Easy attachment of cells or beads with cantilever tip

High Voltage Sample Bias AmplifierCan be used for biasing a sample, e.g., in electro-optical experiments or in Piezo-Response Force Microscopy (PFM).

Key features

+/- 50 V can be applied between sample and tip Software controlled

9

Conductive AFM moduleFor conductivity and I/V measurements on the nanoscale.

Key features

High-performance conductive AFM experiments Recording I/V curves Bias voltage range ± 10 V Noise limit 0.55 pA RMS

Sample holders for opaque samples Sample holder for transparent samples

works with all optical microscopes

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

Page 10: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

Sample stages5

Motorized precision stageOffers automatic motion control for precise positioning of the sample relative to optical axis and AFM probe.

Manual precision stageOffers sub-micron resolution & fine motion control for precise positioning of the AFM tip relative to optical axis and the sample.

Standard stageOffers fine motion control for precise positioning of the AFM tip relative to the sample.

Sample holder for large samplesThe holder module fits directly to the manual or motorized precision stage.

Key features

Transmission illumination capability for inverted optical microscopes like Olympus IX 70/71 Zeiss Axio Observer/Axiovert 100/135/200 Nikon TE 2000 or Ti series Leica DMI 4000/5000 Please specify model upon order Travel range of the sample 20 × 20 mm² Step size (Resolution): ≤ 1 µm Repeatability (unidirectional): ≤ 2 µm

Maximum velocity: 1 mm/s With joystick or software control For automated tiling or mapping applications Manual precision positioning of the AFM tip Stand alone use or for inverted optical microscopes Compatible with all JPK add-ons, glass slides,

Petri dishes etc. Compatible with NanoWizard® II and 3,

ForceRobot® 300 and CellHesion® 200 heads

Key features

Transmission illumination capability for inverted optical microscopes like Olympus IX 70/71 Zeiss Axio Observer/Axiovert 100/135/200 Nikon TE 2000 or Ti series Leica DMI 4000/5000 Please specify model upon order Precise positioning of the sample holder with

thermally decoupled, magnetic fixation

Flexible design for fluid cells, temperature control options, and custom sample holders Detachable from optical microscope for stand

alone operation Drift compensated design Travel range of the sample 20 × 20 mm² Compatible with NanoWizard® II and 3,

ForceRobot® 300 and CellHesion® 200 heads

Key features

Travel range of the AFM head (tip positioning) 10 × 10 mm² Stand alone use in combination with JPK

TopViewOptics™ Magnetic sample holder

Flexible design for fluid cells and different sample holders Rigid, chemical resistive surface Maximum flexibility for customized

sample mounting

Key features

The holder can accommodate larger samples such as microchips or wafers and is equipped with spring clips which can be varied

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

10

Page 11: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

Cantilever holder options6

Standard cantilever holderThe standard holder for all-round applications with a large optical field of view.

Supercut version cantilever holderThe holder is designed for use in air or liquids with removable cantilever spring for maximum cleaning results.

Cantilever holder with electrical tip connectionThe holder is designed for use in air or liquids with a fixed cantilever spring and an electrical tip connection.

Side-view cantilever holder This holder is designed for use in combination with inverted optical microscopes to observe the cantilever region from the side.

Magnetic field cantilever holderThis holder is designed for magnetic cantilever actuation.

Key features

Chemically inert cantilever holder Optimized for the use with top-view optics Robust design using glass and medical steel or gold

spring only Immersible to 8 mm fluid depth

Easy to clean by detergents, ultrasonic bath or autoclaving Easy handling, even with gloves Measurements in droplets or in fluid baths like

Petri dishes or home made fluid cells Works in air and liquid, including aggressive media

Key features

Chemically inert cantilever holder For use with JPK BioCell™, CoverslipHolder™ or

PetriDishHeater ™ for easier navigation Robust design using glass and medical steel or gold

spring only Immersible to 8 mm fluid depth

Easy to clean by detergents, ultrasonic bath or autoclaving Easy handling, even with gloves Measurements in droplets or in fluid baths like

Petri dishes or home made fluid cells Works in air and liquid, including aggressive media

Key features

For air or aqueous solutions

Compatible with JPK BioCell™, CoverslipHolder™ or PetriDishHeater ™ for easier navigation Measurements in fluid droplets or in fluid baths

like Petri dishes or home made fluid cells

Robust design using glass and medical steel Immersible to 8 mm fluid depth Easy to clean Easy handling, even with gloves Electrical tip connection

Key features

For use with JPK BioCell™, CoverslipHolder™ or PetriDishHeater ™ for easier navigation Measurements in fluid droplets or in fluid baths like

Petri dishes or home made fluid cells

Immersible to 8 mm fluid depth Easy to clean Easy handling, even with gloves

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

11

Page 12: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

12

Environmental control options – fluid cells and temperature controls7

BioCell™

The BioCell™ allows for the temperature-dependent study of living cells or single molecules with the NanoWizard® AFM in their native environment. It is therefore particularly suited for applications in cell biology and biomedical research. As an add- on for inverted optical microscopes the NanoWizard® AFM in combination with the BioCell™ offers the unique possibility to simultaneously study temperature-dependent processes like cell motility and metabolism with the AFM and simultaneous advanced optical imaging. During AFM measurement all the optical microscope‘s operation modes, in particular contrast techniques, remain constantly available. Even high-re- solution fluorescence confocal microscopy and single-molecule fluorescence techni- ques are possible since objective lenses with highest numerical aperture can be used.

Key features

Insert for Life Science stage Temperature range: 15 to 60 °C Resolution: 0.1 °C Quick-exchange cover slip bottom

Connections for liquid perfusion and gas flow (e.g., CO2 mix) Compatible to the NanoWizard® AFM sample stage

(Life Science version) Drift-minimized in all direction

CoverslipHolderWith the same design as the BioCell™ but without temperature control, the CoverslipHolder is the ultimate high resolution liquid cell with coverslip bottom.

Key features

Insert for Life Science stage Closed liquid cell with standard coverslip bottom High-N.A. immersion optics possible by exchange-

able cover slip bottom (0.17 mm thickness) Ports for perfusion & gas flow, e.g., CO2 or nitrogen

Superior design for combining AFM and confocal laser scanning Made of glass, steel or gold, and silicon only Easy to clean, also in ultrasonic bath Autoclavable inlet

PetriDishHeater™

The heater system is fully compatible with JPK‘s range of NanoWizard® AFM and CellHesion® systems. This means all the standard imaging and measurement techniques may be applied at temperatures up to 60 ˚C with 0.1 ˚C precision. These include fluorescence, brightfield, phase contrast and DIC, AFM imaging and cell mechanics study. The system also offers per-fusion control employing standard syringe pumps and gas flow of carbon dioxide possible for long term cell studies. Glass bottomed dishes are important for high numerical aperture fluorescence experiments such as confocal laser scanning used in combination with AFM.

Key features

Insert for Life Science stage Temperature range: room temperature up to 60°C Compatible with 35 × 10 mm Petri dishes from WPI

and TPP - plastic or plastic with glass bottom Adaptors for other suppliers such as Matek, Willco,

IWAKI, Ibidi, and BD upon request

Ports for perfusion tubes and gas supply (only available for certain types of Petri dishes) Software control Temperature stability 0.1 K Fully compatible with JPK‘s range of NanoWizard®

AFM and CellHesion® systems Fits to all inverted microscope brands in

combination with a JPK sample stage

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

Page 13: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

13

PetriDishHeater™ for BioMAT™

Shuttle stage with integrated Petri dish heater for JPK BioMaterials workstation.

Key features

Temperature range: room temperature up to 60°C Compatible with 35 × 10 mm Petri dishes from WPI

and TPP – plastic or plastic with glass bottom

Dipping lenses need to be compatible with type of Petri dish Temperature stability 0.1 K Software control

SmallCell™The perfect solution for smallest volume experiments in a hermetically sealed environ-ment, the SmallCell™ is perfect for fluid or gas exchange. The SmallCell™ is compatible with the JPK temperature control systems like the HTHS™, HCM™ and the HCS™.

Key features

Solvent, acid and chloroform resistant Multi-purpose closed fluid cell for small

volumes (< 150 µl) Inlet and outlet ports for perfusion experiments

Glass, steel or gold, and resistive seal only Easy to clean, also in ultrasonic bath Autoclavable Temperature range up to 100 °C

High Temperature Heating Stage (HTHS™)This high performance heating stage is designed for demanding polymer applications as well as for stable long time temperature studies of single molecules or nanoparticles.

3-port small volume SmallCell™

The perfect solution for smallest volume experiments in a hermetically sealed environment, the small volume SmallCell™ is perfect for aqueous solutions exchange. The SmallCell™ is compatible with the JPK temperature control systems like the HTHS™, HCM™ and the HCS™.

Key features

Temperature range from ambient to 300°C in air and ambient to 80°C in fluid when used together with the JPK SmallCell™ Temperature resolution 0.1 °C

Drift minimized in all directions for full tempera- ture ramps simultaneously with AFM imaging No water cooling or fan required

Key features

Closed fluid cell for minimized volumes (< 60 µl) Optimized for aqueous solutions Inlet and outlet ports for perfusion experiments

with Luer connectors Temperature range up to 80 °C

Extra port for small amounts of liquids such as drugs, proteins etc. Polycarbonate, steel or gold, and seal only Easy to clean, also in ultrasonic bath Autoclavable

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

Heating Cooling Module (HCM™)Designed for heating and cooling experiments in gas or liquids with minimized drift in all dimensions.

Key features

Temperature range from -30°C to 120°C ~0-80°C temperature range for experiments

in aqueous solutions Temperature resolution 0.1 °C

Compatible with JPK Manual precision stage and Motorized precision stage

Page 14: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

Heating Cooling Stage (HCS™)Designed for AFM experiments in air or liquids from 0 °C up to 100 °C with minimized drift in all dimensions – HCS™ follows the same design criteria as HTHS™.

Key features

Temperature range from 0 °C to 100 °C Temperature resolution 0.1 °C Twin stage thermoelectric element Drift minimized in all directions for full

temperature ramps simultaneous to AFM imaging

Heatpipe design – no water cooling or fan required Can be used together with closed fluid cells such

as SmallCell™

Electrochemistry solutions8

Temperature controlled ECCell™ Electrochemistry with temperature control and transmission optics such as phase con- trast, DIC or fluorescence together with AFM. The unique combination of temperature controlled electrochemical measurements with high-end optics makes the ECCell™ the ideal tool for combined studies of temperature and potential sensitive biomolecules.

Heating Cooling Stage (HCS™) with electrochemistry cellDesigned for electrochemistry AFM experiments with controlled heating and cooling of the sample.

Key features

Works with transparent or non-transparent substrates Accommodates standard coverslips,

metal or silicon chips or other substrates Temperature range from ambient to 60 °C 500 µl liquid volume with perfusion capability Sealed design for inert gas filling

Wire electrodes and miniature reference electrode Suitable for conductive films or substrates

(e.g., ITO coated glass) Compatible with common potentiostats Allows the use of high numerical aperture lenses

for optimum fluorescence performance Unrestricted high resolution AFM imaging

Key features

For opaque samples Temperature range from 0°C to 100°C Temperature resolution 0.1°C Twin stage thermoelectric element Drift minimized in all directions for full

temperature ramps simultaneous to AFM imaging

Heatpipe design – no water cooling or fan required Top-view optical access for easy navigation 500 µl liquid volume with perfusion capability Sealed design for inert gas filling Wire electrodes and miniature reference electrode

OEM Potentiostats from eDAQJPK offers third party potentiostats for electrochemistry applications together with NanoWizard® systems.

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

14

© eDAQ Pty Ldt.

Page 15: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

Vibration and acoustic isolation9

Active vibration isolation from Accurion

Key features

i4 Series – compact table-top vibration isolation unit

Active Workstation 780 and 900 – active vibration isolation workstations

© Accurion GmbH

Active vibration isolation from Table Stable

Key features

TS 150 Small size table-top vibration isolation system for loads up to 150kg

TS 140 medium size table-top system for loads up to 140kg

© Table Stable Ltd.

Active air damping tables from TMC

Key features

For large setups such as AFM/Raman combinations or confocal microscopy

For less-critical vibration level environments

JPK acoustic enclosureApproved for high performance applications: acoustic hood from JPK for utmost stability and isolation.

JPK base for acoustic enclosureApproved for high performance applications: base frame with top plate from JPK for utmost stability.

Key features

Divisible in two parts for easy transport and setup Special wall design made by sandwich construction

and acoustic foam for best damping results

Optional version without foam for S2 lab conditions 2 front doors with windows Dimensions: 1100 mm × 1100 mm × 1250 mm Demands table with 1100 mm × 1100 mm area

Key features

Welded steel base frame

100 mm MDF sandwich table top Dimensions: footprint 1100 mm × 1100 mm Height adjustable

© Technical Manufacturing Corporation

15

Page 16: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

Optics accessories10

TopViewOptics™ with boom standThe optical system for non transparent samples or substrates such as HOPG, mica, ceramics, implants etc. Can be used in combination with inverted microscopes.

Key features

For opaque samples Long working distance zoom lens from Navitar™ 2 mm - 400 µm field of view

Köhler illumination, fiber light illumination Color CCD camera Easy positioning and focus adjustment

TopViewOptics™ for use with inverted optical microscopes or the JPK BioMAT™

The optical system for non transparent samples or substrates such as HOPG,mica, ceramics, implants etc. Can be used in combination with inverted microscopes.

Key features

For opaque samples Long working distance zoom lens from Navitar™ 2 mm - 400 µm field of view

Köhler illumination, fiber light illumination Color CCD camera Easy positioning and focus adjustment

Raman reflector kitThe optical system for Tip-Enhanced Raman Scattering (upright-TERS) on opaque samples.

Upright Fluorescence Microscope (UFM) KitEnables the combined use of AFM and upright fluorescence zoom microscopy for co-localization experiments on opaque substrates.

Key features

For opaque samples Compatible with common inverted microscope

Raman spectrometer setups

Fits to the JPK Raman reflector kit sample holder and JPK TAO™ modules

TopViewOptics™

The optical system for non transparent samples or substrates such as HOPG, mica, ceramics, metall etc.

Key features

For opaque samples Long working distance zoom lens from Navitar™ 2 mm - 400 µm field of view

Köhler illumination, fiber light illumination Color CCD camera Easy positioning and focus adjustment

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

16

Page 17: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

Fiber coupled detection moduleAllows the precise capture of light emitted by the SPM tip region into a fiber coupled detector. Suitable for home-build SNOM or other light emitting tip experiments.

Key features

Fiber coupler for 50 µm core multi-mode optical fiber (FC connector) Fits to c-mount equipped inverted optical microscopes Precise manual xy positioning of the fiber end

Built-in CCD-camera system for the alignment of emission spot to fiber center Three way optical switch for viewing sample, fiber

end, and semi-transparent overlay

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

17

OEM solutions and small parts11

JPK sample holder for small samplesAdaptor for standard sample holder. Holds magnetically fixed AFM metal stubs.

JPK cable anchorage pillowHeavy weight pillow for fixation of cables to reduce noise coupling.

JPK cantilever changing toolProbe loading station for convenient cantilever exchange.

JPK biocompatible glueFor cantilever or sample fixation, easy removable and biocompatible.

Inverted optical microscope configurationsResearch lines of inverted optical microscopes from Zeiss, Olympus, Nikon, and Leica. Ask the JPK applications team for more information.

Page 18: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

18

OEM syringe pumps JPK offers syringe pumps from several manufacturers.

Aladdin AL-1000 from WPI

Single pump for 1 - 60 mL or 0.5 - 5 µL syringes Step motor with 400 steps per revolution and 5.1 cm/min (max speed)/0.0042 cm/hr (min speed) Pumping rate 1699 mL/hr with 60 mL syringe/0.73 µL/hr with 1 mL syringe

KDS200 from KD Scientific

Two-syringe pump for sizes 10 µL to 140 mL 0.165 µm (1/16 step) advance per microstep Accuracy ± < 1%

JPK 8x FluidicsModule™

Key features

JPK FluidicsModule™ with up to 8 different liquids such as buffer solutions Software-controlled flow rate

Automated incubation or adding of chemicals Comprehensive safety package

AFM cantilevers, substrates and standardsThe NanoWizard® AFM platform is compatible with all commercially available cantilevers. JPK provides cantilevers from leading suppliers like AppNano, Budgetsensors, Mikromasch, NanoSensors, Nanotools, Nanocraft, NanoWorld, Team Nanotec, etc.

AFM Cantilevers

Standard contact and AC mode cantilevers High-resolution EBD tip cantilevers Chemically functionalized cantilevers Coated cantilevers

Tipless cantilevers for customized force experiments Test grids and substrates And many more options

Please visit our online store at cantilevers.jpk.com for an overview.

© NanoWorld AG, nanotools GmbH

JPK spare partsAvailable on request.

Springs for different cantilever holders Fluid cell seals Adapters

Coverslips Tubing for fluid cells

Page 19: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

CCD camerasThe DirectOverlay™ optical integration can be used with any camera. The following CCD cameras are preferred and can be offered directly by JPK.

Andor® Technology

iXon+ EMCCD Luca EMCCD Clara Interline CCD

Jenoptik ProgRes® cameras series, such as

MFcool CFcool

The Imaging Source

FireWire CCD color camera

IDS Imaging Development Systems

Compact USB CCD and CMOS cameras of type µEye®

OEM Scanning Thermal AFM from Anasys

JPK offers third party solutions for scanning thermal applications together with NanoWizard® systems.

OEM Indentation solutions

JPK offers different third party solutions for indentation.

OEM incubators for Live Cell experiments under controlled environments

JPK offers different incubator models for LIVE CELL applications together with NanoWizard® or CellHesion® systems.

Please see dedicated brochures or product notes for more detailed information on our website at www.jpk.com.

© Andor Technology plc.

© Jenoptik AG

© Imaging Source Europe GmbH

© IDS Imaging Development Systems GmbH

19

OEM glove box system for NanoWizard® AFMsThe AFM system can be used in a glove box under controlled atmosphere.

Cellular Adhesion & Cytomechanics Atomic Force Microscopy Automated Force Spectroscopy

© GS Glovebox Systemtechnik GmbH

Page 20: Accessories Handbook 2013 - Apel Laser · Accessories Handbook 3 Contents 1 Control electronics options 4 ... in combination with single molecule fluorescence Automated laser and

JPK WORLDWIDE

JPK instruments Ag

Bouchéstraße 12 12435 Berlin, Germany tel.: +49 30 5331 12070 fax.: +49 30 5331 22555www.jpk.com

NanoWizard, CellHesion, TAO, BioMAT, NanoTracker, ForceRobot, Vortis, DirectOverlay, QI, HyperDrive, RampDesigner and ExperimentPlanner are trademarks or registered trademarks of JPK Instruments AG. All information and specifications are subject to change without notice. All rights reserved. © 2013, JPK Instruments AG

The handbook reflects a large variety of options and will grow further with latest developments. If you cannot find an accessory or operating mode in this handbook ask us directly. JPK is able to deliver customized solutions even for advanced applications.

BERLIN

HEADQUARTERS

UK

SINGAPORE

JAPAN

FRANCE

Be more than a customer – be our partner

Providing the best service and support worldwide is an essential part of JPK‘s philosophy. To accelerate this, JPK founded global offices in Singapore, Tokyo, Paris and Cam-bridge (UK). JPK has the largest applications and service team specialized in life science and nano science applications to support your research.

Our representatives in different countries are hand-selected to offer a service which meets the JPK quality standards. We achieve this through long-term partnership and by continuous training of applications scientists and service engineers. For more detailed questions our JPK applications team is just an email or phone call away from you.

JPK WORLDWIDEJPK WORLDWIDEJPK offers regular user trainings and courses for beginners or experts in our imaging facilities worldwide. Here users can learn to operate new instruments or get tips and tricks ranging from experimental procedures to sample preparation.

To find a representative in your region visit our website or call us.

Visit the JPK web site for more information and sign up for our enewsletter. Web address: www.jpk.com

Follow us on Facebook, Youtube and linkedin.