ac/dc rectifier module 2800w telecom rectifiers for ... · 2800w telecom rectifiers for network,...
TRANSCRIPT
Features 2800W internally fan cooled
AC/DC rectifier module
91% efficiency, including series
output diode
High power density 7.8W/in3,
475mW/cm3
Comprehensive alarms and
signals package
Acoustic noise control
-40ºC to +65ºC operation
Field replaceable dust filter option
Hot-pluggable
Unlimited parallel operation
with active current share, to form
larger DC systems
Typical Applications PSTN, central office
Network datacom
Distributed power systems
N+1 redundant power systems
Mobile base stations
PABX
Telecom hotels
WarrantyThe MRF2800 is under warranty
against faulty manufacture and
faulty components for a period of
two years from the date of delivery.
Please refer to conditions of sale
for full details. We reserve the right
to amend specifications without
prior notification.
DC Series MRF28002800W telecom rectifiers for network, datacom, PSTN,central office, and distributed power applications.
The new MRF2800 Series rectifiers
from APC offer the latest in high
power density technology for critical,
fault tolerant applications. The hot-
pluggable MRF2800 delivers up to
2800 Watts of output power in a 65˚C
ambient temperature. The rectifier's
fan management system auto-
matically adjusts the fan speed to
suit load and ambient temperature.
Input current harmonic distortion is
minimized by the rectifier's active
power factor correction.
Four MRF2800 rectifiers can be
inserted into a 4U high, 23" chassis,
to produce a current of 200A for 48V,
or 400A for 24V systems. Up to
2100A at 54V can be configured in a
single 42U x 19" cabinet using
multiple 3U shelves.
APC offers a wide range of systems
and accessories which utilize the
MRF2800 to provide complete DC
power solutions.
DC Series MX28B1200 system(Photo shows 2 x 1200A DC systems with fuse distribution cabinet)
Input Specifications Minimum Typical Maximum
Voltage Range, VIN Single phase TN-S Operating 176Vac 230Vac 264Vac(as defined by IEC 364) Absolute maximum 300Vac
Frequency 45Hz 66Hz
R.M.S. Current Maximum power output 230Vac input 13.9A176Vac input 16.3A
Peak Inrush Current 264Vac input 19.5A230Vac input 13.0A
Power 2800W output power 3,140WMaximum load (current limit) 3,400W
Apparent Power Factor 98% 99%
Efficiency VIN=230Vac, POUT=2800W 54V 90% 91%Includes integral series output diode 27V 88% 89%
Harmonic Distortion Units comply with the requirementsof EN61000-3-2 3% 10%thd
Turn On Voltage 165Vac 172Vac 176Vac
Turn Off Voltage 145Vac 152Vac 156Vac
Fusing Internally fitted fuses in live and neutral lines 20AT
54V Output Specifications (For Additional Data, See General Output Specifications, p.3) Minimum Typical Maximum
Factory Set Voltage, VOUT 54.4V 54.5V 54.6V
Adjustment Range For more details see “front panel features” section (p.7) 47.8V 58.0V
Maximum terminal voltage 59.0V
Current, IMAX Continuous <65°C ambient. VOUT =54.5V, VIN >198Vac 50.0A
Current Limit Rectifier automatically reduces its current limit set point with changes in ambient temperature, input voltage and output voltage. Current limit characteristics are shown infigures 1 and 2, and table 1 (p.3).
Output Short Circuit See figures 1 and 2 below
Power, PMAX Continuous VIN>198Vac 2,800W
Load Regulation Load change from 0 to IMAX 75mV
Line Regulation Input voltage change over the operating range 75mV
Combined Regulation A combination of load change from 0 to 100% and input 100mVvoltage variation over the operating range
Dynamic Regulation A step change in output current from 10% to 90% of full load ±1VMaximum Deviation
Recovery To within 500mV of final value 2ms
Hold up time VOUT 54.5V dropped to 54.2V, 220Vac input, 50A output 10ms 16msVOUT 54.5V dropped to 40V, 220Vac input, 50A output 32ms
Output Overvoltage 59.0V 59.5V 59.9V
Parallel Voltage Maximum allowable voltage applied to output terminals 80V
MRF2800 Series Standard Input Specification
54V Output Specifications
2 For more details on all APC products go to www.apc.com
Input Specifications Minimum Typical Maximum
Voltage Range, VIN Single phase TN-S Operating 176Vac 277Vac 293Vac(as defined by IEC 364) Absolute maximum 305Vac
Frequency 45Hz 66Hz
R.M.S. Current Maximum power output 277Vac input 14.2A176Vac input 16.0A
Peak Inrush Current 293Vac input 16.0A277Vac input 16.0A
Power 2800W output power 2725W 2889WMaximum load (current limit) 50.0A 53.0A
Apparent Power Factor 98% 99%
Efficiency VIN=230Vac, POUT=2800W 54V 90% 91%Includes integral series output diode 27V 88% 89%
Harmonic Distortion Units comply with the requirementsof EN61000-3-2 3% 10%thd
Turn On Voltage 165Vac 176Vac
Turn Off Voltage 150Vac 176Vac
Fusing Internally fitted fuses in live and neutral lines 16AT
MRF28H54BV50 Input Specification (277V model)
Foldback Setting
60
50
40
30
20
10
00 10 20 30 40 50 60
Constant Current Setting
60
50
40
30
20
10
00 10 20 30 40 50 60
Output Current (Amps) Output Current (Amps)
Outp
ut V
olta
ge
Outp
ut V
olta
ge
Operating Conditions Minimum Typical Maximum
Ambient Temperature Cº VIN VOUT -
65 198 54.5 50.0A 52.5A
65 198 59.0 45.0A 47.8A
65 176 54.5 44.3A 47.1A
65 176 59.0 40.7A 43.2A
General Output Specifications 54V and 27V Minimum Typical Maximum
Remote Sense Total lead voltage drop 1V
Start Up Time From application of line input to output voltage 1.0s 1.5s 3.3sachieving regulation
Rise Time Time for VOUT to rise monotonically to its full value 100ms
Reverse Quiescent Current Source = VOUT connected to output of non energized unit 54V 5mA
Reverse Quiescent Current Source = VOUT connected to output of non energized unit 27V 10mA
Temperature Coefficient Temperature range -25°C to +55°C ±0.015%/°C
Noise, Low Frequency Frequency range 10Hz -100kHz 40mV p-p
Noise, Broadband Frequency range 10Hz - 100MHz 15mV rmsIndividual harmonics 2mV peakComplies with requirements of ETS300386-2-3 and BTNR2511
Noise, Psophometric Weighted to C.C.I.T.T. No. 1 0.7mV rmsC message weighted 29dBrnC
Noise, Acoustic Minimized by allowing 100% IMAX 65°C 198 VacIN 54dBAfan speed to vary 100% IMAX 45°C 230 VacIN 47dBAwith load current 75% IMAX 45°C 230 VacIN 45dBAand ambient temperature 50% IMAX 45°C 230 VacIN 42dBA
50% IMAX 25°C 230 VacIN 38dBA
Series Output Diode Units are fitted with a series diode in the positive output
Series Voltage Units connected in series 150V
54V Output Current Limit Characteristics
MRF2800 Series Operating Conditions
General Output Specifications 54V and 27V
(27V not available in high-input version)
3For more details on all APC products go to www.apc.com
Figure 1 Figure 2
Foldback Setting
30
20
10
0
0 10 20 30 40 50 60 70 80 90 100 110
Output Current (Amps)
Outp
ut V
olta
ge
Constant Current Setting
Output Current (Amps)
30
20
10
0
Outp
ut V
olta
ge
0 10 20 30 40 50 60 70 80 90 100 110
27V Output Current Limit Characteristics
4 For more details on all APC products go to www.apc.com
Figure 3 Figure 4
Operating Conditions Minimum Typical Maximum
Ambient Temperature Cº VIN VOUT -
55 198 27.25 100.0A 105.0A
55 198 29.5 90.0A 95.5A
55 176 27.25 88.7A 94.1A
55 176 29.5 81.3A 86.4A
(Table 2) Operating Conditions
Output Specifications 27V Minimum Typical Maximum
Factory Set Voltage, VOUT 27.20V 27.25V 27.30V
Adjustment Range For more details see "front panel features" section (p.7) 23.9V 29.0V
Maximum Terminal Voltage 29.5V
Current, IMAX Continuous <55°C ambient. VOUT=27.25V, VIN>198Vac 100A
Current Limit Rectifier automatically reduces its current limit set point withchanges in ambient temperature, input voltage and outputvoltage. Current limit characteristics are shown in figures3 and 4 and table 2.
Output Short Circuit See figures 3 and 4 (p.4)
Power, PMAX Continuous VIN>198Vac 2,800W
Load Regulation Load change from 0 to IMAX 50mV
Line Regulation Input voltage change over the operating range 50mV
Combined Regulation A combination of load change from 0 to 100% and input 50mVvoltage variation over the operating range
Dynamic Regulation A step change in output current from 10% to 90% of full load ±500mVMaximum Deviation
Recovery To within 250mV of final value 2ms
Hold up time VOUT 27.25V dropped to 27.1V, 220Vac input, 100A output 9ms 14msVOUT 27.25V dropped to 20V, 220Vac input, 100A output 28ms
Output Overvoltage 31.0V 31.5V 32.0V
Parallel Voltage Maximum allowable voltage applied to output terminals 36.0V
Output Specifications 27V
(27V not available in high-input version)
Signals (available on all versions. See Pinout information p. 6) Minimum Typical Maximum
Post Mate Enable (Input) Connect to (-) sense to enable the unit Start-up delay 2sNote: Connection must be made to operate unit
Current Share Accuracy IOUT = IMAX ±10%
Voltage Trim, Scale factor 54V –1.56V/VSee Figures 5 and 6 27V –0.7V/V
Offset Trim port open circuit 5.1VCurrent VTRIM= 2V -97µAReferenced to (-) sense VTRIM = 8V 97µA
Margin Low Reduction in VOUT with margin low pin connected to (+) sense 2.2V 2.25V 2.3VFactory adjustment range 0V 5V
Current Monitor Monitor output (unloaded). Referenced to (-) sense 97mV/A 100mV/A 103mV/AOutput impedance 5.1kΩ
Auxiliary Output Referenced to opto common Voltage 12VCurrent 100mA
Protected against current and thermal overload
Output Healthy Relay Minimum 'healthy' voltage to 54V 38V 40V 43Vand GREEN LED energize relay and LED 27V 19V 20V 22V
Contact voltage rating 50VBreak current rating 1A
Over Temperature Signal Exceeding internal sensor’s upper limit activates opto and LED 120°Cand RED LED Reset occurs once sensor falls below lower limit 110°C
Program Down (Input) 5V applied to program pin 54V 45.6V 45.8V 46.0Vwith respect to opto common 27V 22.8V 22.9V 23.0V
Remote On/Off (Input) Voltage applied to remote on/off pins Voltage to inhibit 5VCurrent to inhibit 10mA
Remote Boost (Input) Voltage applied to remote boost pin Voltage to activate 5Vwith respect to optos common Current to activate 10mA
Open Collector Opto activates (Output voltage LOW) 0.8VOpto-Coupled Signals Opto resets (Output voltage HIGH) 2.5V
VCE withstand 50.0VSink current (Output voltage LOW) 5mAOpto signals referenced to optos common
Opto characteristics common to all of the following signals:
Standby Signal Remote off activates opto and LEDand YELLOW LED
Input Healthy Signal Input voltage rising activates opto and LED 165V 172V 176Vand YELLOW LED Input voltage falling resets opto and LED 145V 152V 156V
Output Healthy Signal Output voltage above limits, but below 54V 38V 40V 43Vand GREEN LED overvoltage trip activates opto and LED 27V 19V 20V 22V
Current Limit Signal Output current demand >IMAX activates See output specificationand RED LED opto and LED
Overvoltage Trip Signal Output voltage rising activates opto and LED 54V 59.0V 59.5V 59.9Vand RED LED 27V 31.0V 31.5V 32.0V
Reset when line input is interruptedor remote on/off is applied
Output Current Healthy Output current demand >15% IMAX 54V 4.6A 8.6Aand GREEN LED activates opto and LED 27V 9.2A 17.2A
Thermal Control Signal Thermal control of current limit activates opto and LEDand YELLOW LED
Fan Fail Signal Fan failure activates signals and LED and Red LED
Boost (Equalized) Use of boost mode activates opto and LEDActive Signal Activated by front panel switch or remote boost signaland YELLOW LED
MRF2800 Series Signals
Output Voltage Programming
5For more details on all APC products go to www.apc.com
54V Output
0 2 4 6 8 10 12
V trim
V ou
t
65
60
55
50
45
Default (54.5V)
27V Output
0 2 4 6 8 10 12
V trim
V ou
t
32
30
28
26
24
22
Default (27.2V)
Figure 5 Figure 6
6 For more details on all APC products go to www.apc.com
Isolation Minimum Typical Maximum
Primary to Ground Test voltage 1500Vac
Secondary to Ground Test voltage 500Vac
Primary to Secondary Test voltage 3000Vac
Ground Leakage Current 240V, 60Hz input 3.5mA
Output to Ground Voltage Working voltage 150Vdc
Signal to Ground Voltage Working voltage 150Vdc
Signal to Output Voltage Working voltage 150Vdc
Environmental Specifications Minimum Typical Maximum
Ambient Temperature (See table on p. 3) Operational -25°C +65°CStarting -40°C +65°CNon-operational -40°C +85°C
Humidity Non-condensing Operational 0% RH 85% RHNon-Operational 0% RH 95% RH
Altitude Operational 0m 3,000m0ft 10,000 ft
Non-Operational 0m 10,000m0ft 30,000 ft
Vibration Compliant with the requirements of BS2011 Test FcDrop and topple - EN60068-2-31 Test EcBump - EN60068-2-47 Test EbTransportation - BS2011 Part 2.1 Test Fc in original packingDrop - EN60068-2-32 Test Ed in original packing
Pollution EN60950 degree 2 i.e. office type environments
MRF2800 Series Environmental Specifications
MRF2800 Series Isolation
Electromagnetic Compatibility
Emission Compliant with EN50081-1(92) with compliance to the following specific conditions:Conducted input 0 – 2kHz EN61000-3-2Conducted input 0.15 – 30MHz EN55022-BRadiated 0.03 – 1GHz EN55022-A at 10mConducted output ETS300386-2-3
Immunity Compliant with EN50082-1(92) with compliance to the following specific conditions:ESD - EN61000-4-2 failure criteria A. 4kV contact.RF Field - EN61000-4-3. 3Vm–1 80% amplitude modulation 0.08 – 1GHz.Fast Transients - EN61000-4-4 failure criteria B. 1kV on ac line, 500V on dc lines.Surge - EN61000-4-5. 2kV line to ground, 1kV line to line on ac input. 500V line to ground and line to line on dc output.Conducted RF - EN61000-4-6. 3Vrms 80% amplitude modulation 0.15 – 80MHz
MRF2800 Series Electromagnetic Compatibility
Approvals and Safety Standards
EN60950 CE marked to the EC low voltage directive
UL1950 CSA NRTL/C approved, file number LR58666
C22.2 #950 CSA NRTL/C approved, file number LR58666
All versions are reliably SELV. For operation above 60V, a non-SELV version must be ordered. Contact APC for details.
This power supply is designed for incorporation within an enclosure. For user safety, the enclosure must protect the user against accidentalcontact with any electrical hazard, associated with the power supply.
Approvals and Safety Standards
Front Panel Features Minimum Typical Maximum
Test Points Output impedence 5.1kΩ Voltage Current 97mV/A 100mV/A 103mV/A
Float/Boost Select Switch selectable higher or lower preset outputvoltage/current limit. Remote boost (input) overrides selection
Float Voltage Adjust 54V 52.0V 58.0V27V 26.0V 29.0V
Boost (Equalized) 54V 53.0V 60.0VVoltage Adjust 27V 26.5V 30.0V
MRF2800 Series Front Panel Features
Signals Pinout Information
7For more details on all APC products go to www.apc.com
Mechanical Specifications MRF28H
External Dimensions 5.0 x 5.5 x 13.0 in. (127.0 x 139.7 x 330.6 mm)
Front Panel Dimensions See mechanical drawing (p.8) 5.2 x 8.7 in. (132.1 x 221 mm)
Weight 11.0 lb. (5.0 kg)
Fixings Units are designed for power shelf mounting
Mounting Orientation See p.8 for mounting options
Ventilation and Cooling Free air flow through the ventilation slots in the front and rear of the unit is required. Units are cooled by integral,customer replaceable fan. Typical full flow 100cfm.
Finish Front panel is finished in grey with grey legend and the body is finished in gold colored chemical etch
Connectors See below
Dust Filter (Optional) Reticulated, open cell polyester based polyurethane foam. See drawing below.
Mechanical Specifications
Pin Function Pin Function
a1 Reserved b1 Reserved
a2 Fan fail b2 Remote boost
a3 Post mate enable b3 Boost (equalize) Active opto
a4 Standby opto b4 Reserved
a5 Program down b5 Reserved
a6 Auxiliary output b6 Current limit program
a7 Reserved b7 Output current healthy opto
a8 Over temperature opto b8 (-) sense
a9 Thermal control opto b9 Voltage trim
a10 Relay normally closed contact b10 Over voltage opto
a11 Relay common b11 Current limit opto
a12 Relay normally open contact b12 Output healthy opto
a13 Current share b13 Input healthy opto
a14 Remote on/off (com) b14 Optos common
a15 Remote on/off (+ve) b15 Current monitor
a16 Margin low b16 (+) sense
The unit requires a link between pin a3 (post mate enable) and pin b8(negative sense) to operate.
Expanded View Showing Dust Filter
Connector details (hot-pluggable connection)
OutputLine Input
Signals
Pin 1a Pin 1b
Rectifier mounted part:Part B 32 Way Harting 09 22 132 6921SiemensV42254-B1300-B320
Customer/Backplatemounted part:SiemensV42254-B2202-B320
Right angle part:SiemensV42254-B2202-Q320Harting09 27 132 6801
Rectifier mounted part:Positronic SK2790
Customer/Backplatemounted part:Positronic SK2791
Right angle part:Positronic SK2287
Customer/Backplatemounted part:Elcon 538 17 001 00(2 per rectifier required)
(2.1
9in.
)
12.7
(4.97 ± 0.008in.)
126.3 ± 0.22.9
39.1
17.8
(0.7
0in.
)
AIRFLOW
(1.2
9in.
)(5
.48
± 0.
016i
n.)
139.
3 ±
0.4
32.7
177.
0 (6
.97i
n.)
(0.06in.)
1.5
(4.9
9 ±
0.00
8in.
)(0
.06i
n.)
1.5
126.
8 ±
0.2
6.5 (0.26in.) DIA. HOLE
(2.60in.)
66.05
132.1 (5.20in.)
8.4
(0.3
3in.
)
(1.69in.)
43.0 222.3 (8.75in.)
(0.5
1in.
)10
1.6
(4.0
0in.
)
(0.11in.)
93.9 (3.69in.)
50.1 (1.97in.)
(1.54in.)
(1.3
75in
.)
55.7
34.9
(0.5
0in.
)
AIRFLOW
(0.06in.)
1.5 328.7 (12.94in.) 4.2 (INPUT)
(0.17in.)
5.0
(0.19in.)
(SIGNALS)
12.8
5
0.5 (0.019in.) PLASTIC SLIDE
0.5 (0.019in.) PLASTIC SLIDE
4 x M4 FIXINGS
(ON REAR FACE)
ACCESS TO MODE SWITCHES
146.8 (5.78in.)
132.
5 (5
.22i
n.)
137.8 (5.43in.)
83.2
(3.2
7in.
)
SOUTHCO ADJUSTABLE GRIP LATCH
PART No. 27-10-501-20
(0.18in.)
(0.68in.)
138.8 ± 0.4
(5.47 ± 0.016in.)17.3
4.5
50.6
(1.9
9in.
)
94.4
(3.7
2in.
)
(1.375in.)(0.48in.)
34.9
(2.17in.)
55.2
12.2
(1.5
6in.
)39
.6
Output
HealthyHealthy
Healthy
OutputOutput
IVIV
0
1
V
I
0
1
+V +I V I+V +I V I
BelowDetailPanelFrontSee
See
PanelDetail
Front
Below
MRF28HXXXH
Detail 1 - See Figure 9(pg. 10)
Dimensions
MRF28HXXXV
Units in mm (inches)
wwwwww.apc.com.apc.com
R
DC Series Rectifier
www.apc.com
R
DC Series Rectifierwwwwww.apc.com.apc.com
R
Output
Healthy
Healthy
Output
IVIV
0
1
V
I
0
1
Equalize
Boost/
Float
COM
+V
+I
Curr Limit
Thm Cont
I/P OK
O/P OK
O/P Curr
Overvolts
Standby
Overtemp
Fan Fail
Thermal Control
Current Limit
Overtemp
Overvolts
Fan Fail
Standby
Output Current
Input Healthy
Output Healthy
+V +I V I+V +I V I
FloatCOM Equalize
Boost/
B - signals
Front Panel Detail
www.apc.com
R
www.apc.com
R
www.apc.com
R
DC Series
Rectifier Operating Mode Switches
Mode setting switches are accessed through the side face of the rectifier.
Switch Number Switch Set OFF Switch Set ON Standard Setting
1 (+) Sense remote (+) Sense local ON
2 (-) Sense remote (-) Sense local ON
3 Output set 54.5V/27.25V Reduce output by at least 4.2V/2.1VTo offset output voltage adjust range OFF
4 Normal Voltage Regulation Voltage droop regulation OFF
5 Constant current limit Foldback current limit ON
Rectifier Operating Mode Switches
Dimensions
Front Panel Detail
8For more details on all APC products go to www.apc.com
Ordering Information
Part Number Output voltage Boost V
1MRF28H54BH 54.5V 57.6V
1MRF28H54BV 54.5V 57.6V
1MRF28H27BH 27.25V 28.8V
1MRF28H27BV 27.25V 28.8V
1MRF28H54BV50 54.5V 57.6V 277Vac nominal input
Note: All units are factory set to local sense and foldback current limit. 54V units have a margin low voltage of 52.25V. Consult APC for othersettings. 27V units have a margin low voltage of 25.0V. Consult APC for other settings
Accessory Table
Part Number Product
1MKC2801 Connector kit consisting input output and signals connectors
1MKC2802 Connector kit consisting of right angle input, output and signals connectors
1MS28A MS28A, 19" x 4U mounting shelf to accommodate up to 3 MRF28HXXXV units
1MS28B MS28B, 23" x 4U mounting shelf to accommodate up to 4 MRF28HXXXV units
1MS28CT MS28CT, 19" x 3U mounting shelf to accommodate up to 3 MRF28HXXXH units
1MCA28A Input and signal connector PCB assembly
1MAF28 Replacement Dust filter
1MS28CR Copper riser for side access cabling
Accessory Table
Ordering Information
Example: MRF28H54BV
MRF28 HPackagingH- Standard
54NominalOutputVoltage
BSignalsB - Enhanced
VPackage OrientationH- HorizontalV - Vertical
9 For more details on all APC products go to www.apc.com
For more information call:Tel: 800 800 4APC - US & CanadaTel: 401 789 0204 - World wide
APC CorporateAPC North America 132 Fairgrounds Road,West Kingston, RI 02892 USACall: 800 800 4APCFax: 401 789 3710
APC Latin America5301 Blue Lagoon Drive,Miami, FL 3312602892 USACall: 305 266 5005Fax: 305 266 9695
APC EuropeAPC IrelandBallybrit Business Park, Galway,IrelandCall: +35 391 702000Fax: +35 391 756909
APC Asia PacificAPC AustraliaLevel 1, 27 Northpoint, 100 Miller StreetNorth Sydney, NSW2060Call: +61 2 9955 9366Fax: +61 2 9955 2844
Visit: www.apcc.comE-mail: [email protected] Support: support.apcc.comPowerFax™: 800-347-FAXX
©2001. All rights reserved. All APC trademarks are property of American Power Conversion. Other trademarks are property of their respective owners. Specifications are subject to change without notice.. PART# 996-2180B
APC’s quality systemis certified by ISO9002 standards
APC provides complete DC power solutions for today’s mission-critical communications systems.
Today, more companies than ever are moving their
businesses away from traditional methods of marketing and
distribution to a high-powered Internet model. This move
allows companies to reach more customers and increase
the speed of business. The presence of the Internet makes
proper function of networking hardware critical to the
success of these Web-focused companies. Businesses using
access networks or communication systems depend on
power for vital links to the Internet, and turn to APC for
quality solutions.
APC's new line of DC power solutions is designed to enhance
our end-to-end network protection. APC’s DC series product
family will complement our well-established product families,
such as Smart-UPS®, Symmetra®, Matrix-UPS®, Silcon® and
the many other APC power management peripherals.
APC’s line of fully integrated power systems, power racks,
modular power shelves, distribution cabinets, system
monitoring and battery disconnects, provide complete
power management for telecom, datacom and network
applications. These modular systems offer flexibility and
ensure reliability customers demand when deploying
mission-critical communication systems. When entire
access networks or communications systems depend on
having power for vital links to the internet, customers turn
to APC for solutions.
48V DC Wall-MountedPower System
50A 19" Modular DC PowerSubsystem
Modular Power Systemwith Distribution up to 400A
1200-4800A 23" High PowerDC System