acr systems inc

23
ACR Systems Inc. ISO 9001 Registered World Class Data Loggers

Upload: jamuna

Post on 11-Jan-2016

36 views

Category:

Documents


1 download

DESCRIPTION

ACR Systems Inc. World Class Data Loggers. ISO 9001 Registered. A Brief History, 1983 to Present. Started by Albert C. Rock The original manufacturer of compact data loggers Revolutionized the Chart Recorder Industry Today, 28 people company - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: ACR Systems Inc

ACR Systems Inc.  

ISO 9001 Registered

World Class Data Loggers

Page 2: ACR Systems Inc

A Brief History, 1983 to Present

Started by Albert C. Rock The original manufacturer of compact data loggers Revolutionized the Chart Recorder Industry Today, 28 people company Occupying 12,500 square-foot premises in Surrey, Canada World Wide Reseller Network Shipments of around 10,000 Data Loggers per Year More than 160 products Dedicated to research and development (ensure that the

company remains on the leading edge in the field of data logging).

Customer focus and dedication to quality

ISO 9001 Registered

Page 3: ACR Systems Inc

SmartReader Loggers

• Different modules are available to measure and record:

– Temperature– Relative Humidity– Pressure– Electric Current– Process Signal– Pulse

• Features:– 8 Bit A/D Converter– Quartz Crystal Clock– Lithium Battery

ISO 9001 Registered

Page 4: ACR Systems Inc

SmartReader Loggers

• Memory:– 32 KB– Capacity to store up to 32,767 readings

• Enabling Channels:– Unused channels can be disabled to conserve memory

• Sampling Rates:– Can be set from 8 second to 5 day increments– One channel sampling at 1 minute intervals can record for

32,767 minutes• Sampling Methods:

– Continuous (First-in, First-out)– Stop when full

ISO 9001 Registered

Page 5: ACR Systems Inc

SmartReader Loggers

ISO 9001 Registered

• Loggers have a 3 year warranty• Batteries have a 10 year warranty

Page 6: ACR Systems Inc

SmartReader Loggers

ISO 9001 Registered

• SmartReader Network Using the IC-200, a maximum of 8 loggers can be

networked together

Page 7: ACR Systems Inc

SmartReader Plus Loggers

• Features:– 12 Bit A/D Converter– Quartz Crystal Clock– Lithium Battery

• Fast Read:– Record up to 25 data points per second with the use

of an external power supply

• Alarm Capabilities:– Set high and/or low alarm thresholds which trigger:

External Alarm Module, or Alarm-Dial-Out

ISO 9001 Registered

Page 8: ACR Systems Inc

SmartReader Plus Loggers

ISO 9001 Registered

• Loggers have a 3 year warranty• Batteries have a 10 year warranty

Page 9: ACR Systems Inc

SmartReader Plus Loggers

ISO 9001 Registered

• SmartReader Plus Network Using Y-connector and: Unshielded cable:

Maximum 3 Loggers Shielded cable & Network Power Supply:

Maximum 10 Loggers

Page 10: ACR Systems Inc

Owl Loggers

ISO 9001 Registered

• Different modules are available to measure and record:

– Temperature– AC Current– DC Current– DC Voltage

• Features:– 8 Bit A/D Converter– Single Channel, Configurable– Quartz Crystal Clock– Optical Data Transfer– Lithium Battery

Page 11: ACR Systems Inc

Owl Loggers

• Memory:

– 32 KB– Capacity to store up to 32,767 readings

• Sampling Rates:

– Can be set from 8 second to 12 hour increments– Fast Read Mode allows for samples every 0.2 seconds

• Sampling Methods:

– Continuous (First-in, First-out)– Stop when full

• Alarm Capabilities:

– Set high and/or low alarm thresholds– Optical port can be set to flash when alarm is triggered

ISO 9001 Registered

Page 12: ACR Systems Inc

Owl Loggers

ISO 9001 Registered

• Loggers have a 3 year warranty• Batteries have a 10 year warranty

Page 13: ACR Systems Inc

Nautilus Loggers

ISO 9001 Registered

• Waterproof Data Logger

• Single 8 Bit Channel

• Pressure Range up to 2000 P.S.I.

• Anodized Aluminum or Stainless Steel

• Nautilus85 Range: -40°C to 85°C

• Nautilus135 Range: 10°C to 135°C

Page 14: ACR Systems Inc

Nautilus Loggers

ISO 9001 Registered

• Memory & Sampling:– 32KB of Memory– Capable of storing up to 244,800 readings with data

compression– Sampling rates from 8 seconds to 34 minutes– Continuous or FIFO Sampling– Spot or Average Sampling– Delayed Start Capabilities

Page 15: ACR Systems Inc

Nautilus Loggers

ISO 9001 Registered

• Battery and Logger have a 3 year warranty

Page 16: ACR Systems Inc

JR-1000 Loggers

ISO 9001 Registered

• Single 8-bit Temperature Channel

• Plugs directly into serial port without the need for an interface cable

• Operating Range: -40°C to 85°C

• Accuracy: ±0.2 °C @ 25 °C

• Sampling Rates: 8 seconds to 34 minutes

• 32KB of Memory– Up to 244,800 readings when using compression

Page 17: ACR Systems Inc

JR-1000 Loggers

ISO 9001 Registered

• Also available in Intrinsically Safe version (JR-1000)

• Five year warranty under normal use

Page 18: ACR Systems Inc

TRH-1000 Loggers

ISO 9001 Registered

• Low-cost, easy-to-use data logger• Two channels

Temperature Relative Humidity

• 64KB of Memory at 8-bits of Resolution• Sampling Methods:

First-In First-Out or Stop When Full Delayed Start Spot or Average

• Sampling rates from 8 seconds to 34 minutes

Page 19: ACR Systems Inc

TRH-1000 Loggers

ISO 9001 Registered

• Range:

-40°C to 70°C

0 to 100% RH

• Five Year Warranty on Battery• One Year Warranty on Logger

Page 20: ACR Systems Inc

SmartButton Loggers

ISO 9001 Registered

• Single Temperature Channel Data Logger with 8-bits of resolution

• 2KB of Memory for 2,048 readings• Range : -10°C to 85°C• Sampling Rates from 1 minute to 255

minutes• Maximum start delay of 255 minutes• Programmable alarm thresholds• One year warranty

Page 21: ACR Systems Inc

SmartButton Loggers

ISO 9001 Registered

• Accuracy -10 to 45°C (14 to 113°F) ±1.0°C (1.8°F) 45.5 to 70°C (114 to 158°F) ±1.5°C (2.7°F) 70.5 to 85°C (159 to 185°F) ±2.5°C (4.5°F)

Page 22: ACR Systems Inc

PowerWatch Loggers

ISO 9001 Registered

• Event triggered recordings• 32KB of Memory• Store up to 4000 events

– Sags– Surges– Impulses– Outages– Frequency variations

• Optical Interface• Built-in EMI and RFI protection

Page 23: ACR Systems Inc

PowerWatch Loggers

ISO 9001 Registered

• Operating limits: -40°C to 70°C

0 to 95% RH