addendum no. 1 tender no . 187-2012 re: roof membrane
TRANSCRIPT
David Ferguson, Manager Construction Services
Purchasing & Materials Management Michael Pacholok, Acting Director
City Hall 18th Floor, West 100 Queen Street West Toronto, Ontario M5H 2N2
July 23, 2012 Reply to: Michael Porcarelli Via Website Posting: 99 Pages Tel: (416) 338-5585
ADDENDUM NO. 1
TENDER NO. 187-2012
RE: ROOF MEMBRANE REPLACEMENT & DRAIN LINE CLEAN OUT AT TORONTO HESCHEL
SCHOOL LOCATED AT 819 SHEPPARD AVE. WEST, TORONTO.
REVISED CLOSING DATE: JULY 26, 2012 AT 12 O’CLOCK NOON LOCAL TIME. Please refer to the above Tender Call document in your possession and be advised of the following Revised Closing Date, Revised Price Schedule Form and Clarification of Information:
1. Closing date has been changed from July 25, 2012 at 12 O'Clock noon local time to the revised closing date of July 26, 2012 at 12 O'Clock noon local time.
REVISED CLOSING DATE
2.
The Price Schedule Form on pages 28 and 29 of 239 is replaced with the enclosed two (2) pages, Revised - Price Schedule Form.
REVISED PRICE SCHEDULE FORM
a) Total Pricing – Option 1 and Option 2;
Added $50,000.00 Cash Allowance line item for possible abatement removal at existing roofing membrane (material presumed to contain asbestos) for roof section areas A, B, C, D, E, F, G, H, J, N and M, as specified for replacement in both Options "1" and "2".
3.
The following information is CLARIFICATION OF INFORMATION
now
provided for clarification purposes:
Phase 1 Environmental Assessment Report (dated October 14, 2009): a) Copies of this report were handed out to all in attendance @ the mandatory site meeting on Wednesday, July 18, 2012. This report makes reference to an asbestos survey report as prepared by Golder Associates in 2008. For your information, please find attached A.B.M. (Asbestos Building Materials) report survey as prepared by Golder Associates Ltd. (dated March 2008), for the T.D.S.B. (Toronto District School Board).
Should you have any questions regarding this addendum contact Michael Porcarelli, Corporate Buyer, at email [email protected]. Please attach this addendum to your Request for Tender document and be governed accordingly. Bidders must acknowledge receipt of all addenda on the space provided on the Tender Call Cover
1 of 99
David Ferguson, Manager Construction Services
Purchasing & Materials Management Michael Pacholok, Acting Director
City Hall 18th Floor, West 100 Queen Street West Toronto, Ontario M5H 2N2
Page as per the Process Terms and Conditions, Section 1, Item 8 - Addenda, of the Tender Call document. All other aspects of the Tender remain the same. Yours truly, David Ferguson, Manager, Construction Services Purchasing & Materials Management
2 of 99
Section 3 – Tender Submission Package Pricing Form
Tender Call No. 187-2012 Contract No. N/A
PMMD V 4.0 Page 3-7
REVISED - PRICE SCHEDULE FORM (July 23, 2012) Roof Membrane Replacement & Drain Line Clean Out at Toronto Heschel School located at 819 Sheppard Ave. West, Toronto. All Bidders Must
Complete In Full And Submit This Price Form Page With Your Bid Submission By The Closing Time And Date.
Bidders That Do Not Fully Complete This Form (Such As Leaving Lines Blank), Or Have Unclear Answers (Such As "N/A" Or "Tbd", Dashes Or Hyphens) Will Be Disqualified. Prices That Are Intended To Be Zero Cost/No Charge To The City Are To Be Submitted In The Space Provided In The Price Schedule As "$0.00" Or "Zero". " All Spaces For The Aforementioned Information Must Be Completed In Ink Ensuring The Printing Is Clear And Legible. Where Included, The Supplementary List Of Prices Required For Extra Work Form Must Also Be Completed. NAME OF CONTRACTOR: __________________________________________________________ The City reserves the right to award work identified for this Tender Price Schedule Form in whole or part should it be deemed in the interest of the City to do so. The City may exercise the option of awarding either Option "1" or Option "2" to the successful proponent, as per the approved budget schedule for this project and scheduled construction start time-line.
ALL PRICES SHALL INCLUDE ALL LABOUR AND MATERIAL.
Table – 1: Pricing – Option 1
(H.S.T. excluded)
Item Description Price ($)
1 Replacement of roof sections A, B, C, E, F, G, H, and M - New Roofing System R1 $_____________________
2 Replacement of roof section J – New Roofing System R2 $_____________________
3 Replacement of roof sections D & N – New Roofing System R5 $_____________________
4 Cleaning and roof repairs on roof sections K and L $_____________________
5 Total (item #1 to item #4) $_____________________
continued …
3 of 99
Section 3 – Tender Submission Package Pricing Form
Tender Call No. 187-2012 Contract No. N/A
PMMD V 4.0 Page 3-8
REVISED - PRICE SCHEDULE FORM (July 23, 2012) Table – 2: Pricing – Option 2
(H.S.T. excluded)
Item Description
Price ($)
1 Replacement of roof sections A, B, C, E, F, G, H, and M - New Roofing System R3 $_____________________
2 Replacement of roof section J – New Roofing System R4 $_____________________
3 Replacement of roof sections D & N – New Roofing System R5 $_____________________
4 Cleaning and roof repairs on roof sections K and L $_____________________
5 Total (item #1 to item #4) $_____________________
Total Pricing – Option 1 and Option 2
1
Total (item #5 from Table – 1: Pricing – Option 1) (H.S.T. excluded)
$_____________________
2
Total (item #5 from Table – 2: Pricing – Option 2) (H.S.T. excluded)
$_____________________
3 Contingency Allowance $ 25,000.00
4 Cash Allowance $ 50,000.00
5 Total of above items 1, 2, 3 and 4 $_____________________
6 HST Calculation (13% of item 5)
$_____________________
Grand Total Lump Sum Amount: (Above items 5 and 6) (Please indicate this amount on the Tender Call Cover Page)
$_____________________
Substantial Performance project completion date will be no later than September 30, 2012.
4 of 99
Golder Associates Ltd.
2390 Argentia Road Mississauga, Ontario, Canada L5N 5Z7 Telephone: (905) 567-4444 Fax: (905) 567-6561
OFFICES ACROSS NORTH AMERICA, SOUTH AMERICA, EUROPE, AFRICA, ASIA AND AUSTRALASIA
REPORT ON
ASBESTOS BUILDING MATERIALS SURVEY
DUBLIN PUBLIC SCHOOL 819 SHEPPARD AVENUE WEST
SAP ID# 3088
Submitted to:
Toronto District School Board
Facility Services
15 Oakburn Crescent
Toronto, Ontario
M2N 2T5
DISTRIBUTION:
3 Copies - Toronto District School Board, Toronto, Ontario
2 Copies - Golder Associates Ltd., Mississauga, Ontario
March 2008 06-1113-212
5 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - i - 06-1113-212
Golder Associates
TABLE OF CONTENTS
1.0 INTRODUCTION ......................................................................................... 1 1.1 Scope of Work ....................................................................................... 1
2.0 METHODOLOGY ........................................................................................ 1 2.1 General Information ............................................................................... 1 2.2 Area Identification .................................................................................. 2 2.3 System Classification ............................................................................. 2 2.4 Asbestos Sampling and Analysis ........................................................... 3 2.5 Sampled and Presumed ACM Materials (PACM) ................................... 4 2.6 Existing Sample Data ............................................................................. 5 2.7 Condition of Material .............................................................................. 5 2.8 Accessibility of Material .......................................................................... 7 2.9 Response Actions .................................................................................. 8 2.10 Limitations of Survey .............................................................................. 9 2.11 General Recommendations .................................................................. 10
3.0 FINDINGS ................................................................................................. 11 3.1 Site-Specific Information ...................................................................... 11 3.2 Confirmed And Presumed ACM ........................................................... 12
4.0 RECOMMENDATIONS ............................................................................. 12 5.0 Limitations and Use of Report ................................................................... 12 6.0 CLOSURE ................................................................................................. 13 ATTACHMENT Abbreviations and Definitions
TABLES Table 1: Bulk Material Sampling Requirements Table 2: Specific Sampling and Assumption Criteria Table 3: Condition of Spray Applied Fireproofing, Thermal/Acoustic Insulation and Texture Finishes Table 4: Mechanical Insulation Table 5: Non-friable and Potentially Friable Material Table 6: Evaluation of ACM Debris Table 7: Accessibility Table 8: Response Actions Table 9: Action Matrix Table Table 10: Site-Specific Information
APPENDICES Appendix I: Figure SP: Site Location Plan Figure BA: ACM and Sample Location Plan (Basement) Figure 1: ACM and Sample Location Plan (Floor 1) Figure 2: ACM and Sample Location Plan (Floor 2) Appendix II: Laboratory Results Appendix III: Summary of All Asbestos-Containing Materials (ACM & PACM) Appendix IV: Room-by-Room Details: Summary Report by Location
6 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - 1 - 06-1113-212
Golder Associates
1.0 INTRODUCTION
At the request of the Toronto District School Board (“TDSB”), Golder Associates Ltd. (“Golder”)
conducted a survey of Dublin Public School (the Site) to identify building materials that may
contain asbestos. The survey was performed with the objective of compiling an inventory of
asbestos-containing materials (ACMs) and providing recommendations to manage these materials
in accordance with Ontario Regulation 278/05, Regulation respecting Asbestos on Construction
Projects and in Buildings and Repair Operations, made under the Occupational Health and Safety
Act.
1.1 Scope of Work
Golder’s scope of work for this project included the following:
• A review of available Site information including Site plans and existing surveys as well as interviews with available personnel familiar with the Site;
• A Site reconnaissance and walk through (room-by-room) to identify suspect ACMs;
• Sample collection of suspected ACMs;
• Analysis of samples using an independent laboratory accredited by the National Voluntary Laboratory Accreditation Program (NVLAP);
• Transfer of information to eFacility database; and
• Preparation and delivery of a report identifying the presence, location and condition of ACMs (friable and non-friable) and, where necessary, recommendations for repair and or removal of damaged or deteriorated ACMs.
Where possible, Golder used existing reports and data detailing any previous findings related to ACMs.
2.0 METHODOLOGY
2.1 General Information
For the purposes of this survey, all materials used in the construction of the site are considered to
be building “components”. Each component, even those not suspected to contain asbestos, are
assigned a number and are addressed as one “homogeneous material” throughout a building.
Homogeneous Materials are defined by O. Reg. 278/05 as materials that are uniform in colour
and texture. A component number refers to a homogeneous material throughout its full extent,
even if its occurrence is not contiguous or physically connected.
7 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - 2 - 06-1113-212
Golder Associates
2.2 Area Identification
The Site was typically assessed on a room-by-room or area-by-area basis. Each room or area was
then assigned a number. Collectively, rooms or areas are referred to as “areas” in this
assessment. Areas are typically defined as one room, but may include several interconnected
rooms or a portion of a room as identified on the attached drawings. Room or area numbers
provided by TDSB were generally utilized where they were provided. Not all numbers were
necessarily utilized and additional numbers were added as required to accurately delineate areas
for the purposes of collecting asbestos information.
2.3 System Classification
Areas were broken down into “systems” to document the materials present. Systems are used to
group various building materials, referred to as “Components”, into easily recognisable categories
which indicate where they are located. All Components are associated with a system (e.g., wall,
floor, piping, mechanical). The systems were broken down for each area as described below:
Floor: The floor or lower surface of an area. May include the roofing material in the “roof” area description. May not be present in areas such as vertical pipe chases or two-storey areas.
Wall : Walls or vertical perimeter of an area. May include the exterior walls for the “exterior” area of a Site. May not be present if area is defined as a portion of an area with no vertical perimeter surfaces.
Ceiling: An architectural or acoustical upper barrier or surface in an area which is typically suspended from, or attached to, the upper structural element (deck). May not be present in vertical shafts or where structural deck is exposed.
Structure: Structural element of the Site which usually refers to the concrete or metal upper deck, beams, columns or joists in an area or the fireproofing material applied to the surface of these materials.
Ductwork : Ducts and associated connectors which facilitate air movement between areas.
Piping Systems: Pipes which typically transport liquids and are commonly insulated. Does not include conduit for electrical services.
Mechanical Equipment: Boilers, chillers, hot water tanks, air handling units and other mechanical equipment typically present in mechanical rooms.
Other: Other items that don’t fit into the above categories including chalk boards, bench tops, window sealers or fire doors.
8 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - 3 - 06-1113-212
Golder Associates
2.4 Asbestos Sampling and Analysis
The survey included a visual assessment of areas accessible at the time of the survey in order to
determine the type and extent of ACMs within the Site.
Bulk samples of each “homogeneous material” or “component” suspected to contain asbestos
were collected and submitted for laboratory analysis. The number of samples of each
“homogeneous material” was in accordance with Table 1 “Bulk Material Samples” of O. Reg.
278/05. Sample analysis of each “homogeneous material” was stopped at the first positive result.
Table 1 - Bulk Material Sampling Requirements
Type of material Size of area of homogeneous material Minimum
# of samples
Surfacing material, including without limitation material that is applied to surfaces by spraying, by troweling or otherwise. Examples include acoustical plaster on ceilings and fireproofing materials on structural members
Less than 90 square metres (969 square feet) 3 90 or more square metres, but less than 450 square metres (4,844 square feet) 5
450 or more square metres 7
Thermal insulation, except as described below
any size 3
Thermal insulation patch Less than 2 linear metres (6.6 linear feet) or 0.5 square metres (5.4 square feet) 1
Other material Any size 3
Sample collection consisted of obtaining a small volume of suspect material, placing it in an
individual plastic bag, and submitting it to an independent laboratory (International Asbestos
Testing Laboratories (IATL) of Mt. Laurel, N.J. or EMSL Analytical Inc of Westmount, N.J.) for
asbestos content analysis. Both labs are certified under The National Voluntary Laboratory
Accreditation Program (NVLAP) for Laboratory Proficiency. Samples were assigned a sample
number and series number to indicate how many samples of each homogeneous material, or
component, were collected. For example, the first sample of a component would be 3147-1-
3007-3171-01, where 3147 is the SAP ID#, 1 is the building at the Site (may be more than one),
3007 is a generic component code, 3171 is the component number, and 01 is the first sample of
this component. Samples of materials suspected of containing asbestos were submitted, along
with a chain of custody, to the lab for asbestos content analysis. The laboratory was instructed to
stop once a positive result (0.5% or greater) was obtained for any sample in a homogeneous
material group. Some samples may be identified by the laboratory to contain multiple phases or
layers which require separation and individual analysis of each separate phase or layer.
9 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - 4 - 06-1113-212
Golder Associates
Samples were analyzed for asbestos type and percentage content using Polarized Light
Microscopy in accordance with U.S. Environmental Protection Agency (USEPA) methodologies
and dispersion staining techniques (EPA 600/R-93/116). Samples were analyzed to a minimum
detection limit of 0.5% to meet the requirements of O.Reg. 278/05. The identification of asbestos
fibres in bulk materials is based on a collective set of parameters dependent on the unique shape
and crystallographic properties of each fibre as viewed through the microscope. This method is
useful for the qualitative identification of asbestos and the semi-quantitative determination of
asbestos content in bulk materials expressed as a percent of projected area. The method identifies
types of asbestos and also measures percent of asbestos as perceived by the analyst in comparison
to standard area projections and the analyst’s experience. Analytical results are reported from
trace (less than the limit of detection), to the percentage counted or estimated. Materials reported
to contain less than 0.5% asbestos, including those referred to as less than the limit of detection
(<LOD), are not considered to be asbestos-containing under current regulations.
2.5 Sampled and Presumed ACM Materials (PACM)
For the purposes of this assessment, specific materials (components) have been designated as
“Presumed Asbestos-Containing Materials” (PACM) and have not been sampled. Materials
presumed to contain asbestos may also be referred to as “Assumed” or “Suspect” materials.
Other materials have been designated as requiring sampling wherever they were present. As
required by O.Reg. 278/05, all PACM shall be treated as ACM until appropriate sampling proves
otherwise. All references to ACM in this report shall include PACM unless specifically noted
otherwise. Specifically designated materials are presented in Table 2.
Table 2 - Specific Sampling and Assumption Criteria
Material Sampled Materials Presumed to Contain Asbestos (PACM) • ceiling tiles • pipe covering papers • texture coatings • textiles • pipe and other mechanical
insulation • sprayed fireproofing
• vinyl floor tile • vinyl sheet flooring • asbestos cement board • asbestos cement pipe • gaskets and packing • expansion joints • flex connections • roofing felts and sealers • putty. caulking, window glazing and mastics • friction materials • drywall joint compound • wall and ceiling plaster • concealed vermiculite • other suspect materials
10 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - 5 - 06-1113-212
Golder Associates
2.6 Existing Sample Data
Existing bulk sampling information was obtained by Golder through reviewing existing surveys
or other information provided by TDSB. Where possible, Golder has relied on laboratory results
from previously collected samples, referred to as Historical Samples. Historical samples are
denoted in this report and it’s appendices by “-H” at the end of the sample number. In some
instances, final copies of the original laboratory reports were not available for review. In these
cases, the reported type and percentage of asbestos present may be approximate. This
information was used only if the surveyor, based on their experience with asbestos materials,
could clearly associate the historical sample information with the material (component) present at
the Site. Although historical sample information was used to confirm the presence of asbestos in
suspect materials, components were not deemed to be non-asbestos based on historical samples
unless they were of recent vintage and met all requirements outlined in O. Reg. 278/05. Existing
analytical data for materials that were analyzed to a detection limit of greater than 0.5% or
materials that could not be clearly linked to materials existing at the Site, as determined during
this survey, were not relied upon.
2.7 Condition of Material
Each ACM and PACM identified as part of this assessment was evaluated based on it’s condition.
The criteria used to assess the condition of a material, as defined by TDSB, are summarized in
Tables 3, 4, 5 and 6.
Table 3 - Condition of Spray Applied Fireproofing, Thermal/Acoustic Insulation and Texture Finishes
Good
Surface of material shows no significant signs of damage, deterioration or delamination. Good condition includes fireproofing or texture finishes that are not encapsulated or painted and where no delamination or damage is observed, and encapsulated fireproofing or texture finishes where the encapsulation has been applied after the damage or fallout occurred.
Poor Sprayed materials show signs of damage, delamination or deterioration. Significant delamination to surface of ACM spray.
The above table refers to evaluating the condition of ACM sprayed or trowelled fireproofing, sprayed or trowelled thermal/acoustic insulation (non-mechanical), or texture, decorative or acoustic finishes. In observation areas where damage exists in isolated locations, both good and poor condition may be applicable. The extent or percentage of each condition has been recorded. Fair condition has not been utilized in the evaluation of sprayed fireproofing or texture coat finishes The evaluation of ACM sprayed or trowelled fireproofing, sprayed or trowelled thermal insulation (non-mechanical), or texture, decorative or acoustic finishes which are present above ceilings, may be limited by building components such as ducts or full height walls that obstruct observations.
11 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - 6 - 06-1113-212
Golder Associates
Table 4 - Mechanical Insulation
Good
Insulation is completely covered in jacketing and exhibits no evidence of damage or deterioration. No insulation is exposed. Includes conditions where the jacketing has minor damage (i.e., scuffs or stains), but the jacketing is not penetrated.
Fair
Minor penetrating damage to jacketed insulation (cuts, tears, nicks, deterioration or delamination) or undamaged insulation that had never been jacketed. Insulation is exposed but not showing surface disintegration. The extent of missing insulation ranges from minor to none. Damage can be repaired.
Poor Original insulation jacket is missing, damaged, deteriorated or delaminated. Insulation is exposed and significant areas have been dislodged. Damage cannot be readily repaired.
The evaluation of mechanical insulation may be limited by building components such as ducts or full height walls that obstruct observations. It is not possible to observe each foot of mechanical insulation from all angles.
Table 5 - Non-friable and Potentially Friable Material
Good No significant damage. Material may be cracked or broken but is stable and not likely to become friable upon casual contact. If there is no friable debris present, the condition is rated as good
Poor Material is severely damaged. Loose debris is present or binder has disintegrated to the point where the material has become friable.
The condition of non-friable or potentially friable ACM, such as ceiling tiles, drywall joint compound and plaster finishes containing asbestos and manufactured products such as asbestos cement products (Transite) have the potential to become friable when handled. Potentially Friable refers to ceiling tiles which can become friable very easily, vinyl sheet flooring with asbestos backing paper which can remain stuck to the substrate during removal of the vinyl, heavily deteriorated non-friable materials and wall plaster which is considered friable at the time of demolition. The evaluation of the condition of non-friable and potentially friable materials does not utilize a fair condition rating.
12 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - 7 - 06-1113-212
Golder Associates
Table 6 - Evaluation of ACM Debris
Poor Debris from ACM (friable or non-friable) is inherently in a deteriorated state having become dislodged from the source material.
The presence of ACM debris is noted separately from the presumed ACM source and is referred to as debris. The identification of the exact location or presence of debris on the top of ceiling tiles is limited by the number of observations made and the presence of building components such as ducts or full height walls that obstruct observations. Note: Workers are advised to be watchful for the presence of debris when accessing or working in proximity to mechanical insulation or above ceilings in areas with ACM regardless of the reported presence or absence of debris.
2.8 Accessibility of Material
Materials are rated based on the ease with which they can be reached, and therefore physically
disturbed. The accessibility of materials known or suspected of being ACM is rated according to
the criteria presented in Table 7:
Table 7 - Accessibility
Access (A)
Materials within reach (from floor level) of all Site users. These also include materials in gymnasiums, workshops, and storage areas where activities of the Site users may result in disturbance of ACM not normally within reach from floor level. Visibility would typically be noted as “YES” for these items, except for under sinks, in closets, or other commonly accessed spaces.
Access (B)
Materials in frequently entered maintenance areas of the Site within reach of maintenance staff, without the need for a ladder. Includes materials within reach from a fixed ladder or catwalk (i.e., tops of equipment, mezzanines, and frequently entered pipe chases, tunnels and service areas). Visibility would typically be noted as “YES” for these items.
Access (C)
Materials above 8'-0" where use of a ladder is required to reach the ACM. Only includes ACM materials that are exposed to view without the removal or opening of other building components such as ceiling tiles, or service access doors or hatches. Does not include materials in infrequently accessed service areas of the Site. Visibility would be noted as “YES” for these items.
Access (D)
Materials that can not be reached without removing a building component, including lay-in ceilings or access panels in solid ceiling systems. Includes rarely entered crawl spaces, attic spaces, etc. Observations will be limited to the extent visible from access points. Visibility would be noted as “NO” for these items.
Access (E)
Materials behind inaccessible solid ceiling systems, walls or mechanical equipment, etc., where demolition of the ceiling, wall or equipment etc. is required to reach the ACM. These materials are visually identified by the surveyor, often with difficulty, and there may be uncertainty associated with them. Evaluation of condition and extent of ACM is limited or impossible, depending on the surveyor's ability to visually examine these materials. Visibility would be noted as “NO” for these items.
13 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - 8 - 06-1113-212
Golder Associates
2.9 Response Actions
For each ACM or assumed ACM identified, a specific response action has been assigned. The
assigned response action is based on consideration of condition and accessibility. These actions
are based on the likely risk posed by the material. Damaged materials that are easily accessible
pose the greatest risk and good condition materials in inaccessible areas pose the least risk.
Response actions range from immediate clean-up of debris to ongoing routine inspections of non-
friable material in good condition.
In any building with friable asbestos, current regulations require implementation of an Asbestos
Management Program (AMP) which includes provisions for training and routine inspections of
ACM. As of November 1, 2007, these regulations will further require implementation of an AMP
for buildings containing non-friable ACM. Depending on the condition and the accessibility of
ACMs, more active measures such as repair or removal may be required. In the event of a
building alteration, it will be necessary to remove all ACM, regardless of condition, that is likely
to be disturbed by planned renovation, demolition or maintenance work. Response Actions and
their definitions are presented in Table 8.
Table 8 - Response Actions
Action 1
Immediate Clean-Up of Debris Restrict access that is likely to cause a disturbance of the ACM debris and clean up ACM debris immediately. The surveyor will immediately (within 24 hours) notify TDSB’s Environmental Coordinator of this condition.
Action 2
Type 2 Precautions for Entry into Areas with ACM Debris Restrict access to the area to persons utilizing Type 2 asbestos precautions as per O.Reg. 278/05. These precautions will be required until the ACM debris has been cleaned up, and the source of the debris has been stabilized or removed.
Action 3 ACM Removal Required for Compliance Remove ACM in compliance with regulatory requirements of O.Reg. 278/05.
Action 4 Type 2 Access into Areas Where ACM is Present and Likely to be Disturbed Use Type 2 asbestos precautions as per O.Reg. 278/05 when entry or access into an area is likely to disturb the ACM. .
Action 5 ACM Repair Repair ACM found in fair condition, and not likely to be damaged again or disturbed by normal use of the area or room.
Action 6 Routine Inspection Maintain routine inspection of ACM to monitor condition.
14 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - 9 - 06-1113-212
Golder Associates
Based on the accessibility and action criteria presented above, the following Action Matrix Table,
Table 9, outlines appropriate action codes for all ACM and PACM identified.
Table 9 – Action Matrix Table
Access Condition
Debris Good Fair Poor
(A) Action 6 Action 5 Action 3 Action 1
(B) Action 6 Action 5 Action 3 Action 1
(C) Action 6 Action 5 Action 4 Action 2
(D) Action 6 Action 6 Action 4 Action 2
(E) Action 6 Action 6 Action 6 Action 6
2.10 Limitations of Survey
Only accessible areas of the Site were examined during our assessment. An accessible area is
defined as an area above a suspended ceiling tile, within a manufactured access hatch or behind a
closed door, not impeded by any structure, article or item. Ceiling spaces (between suspended
ceiling and structural deck) that were not accessible at the time of this assessment should be
considered to contain asbestos until proven otherwise. If these spaces are to be accessed for any
reason, such as a roof leak, etc., an inspection should be conducted by a competent person and
any suspect ACM should be sampled or presumed to contain asbestos. An enclosed area that
requires demolition to gain entry or a temporary access hatch that is not readily opened is
considered inaccessible. This report reflects the observations of accessed areas, and analytical
results of materials sampled during the survey.
Carpets were not removed to determine materials below as it is possible that asbestos materials
may be present under a portion of the carpeted area. Asbestos-containing flooring material
should be suspected below all carpets until proven otherwise. In addition, mastic associated with
any floor tiles or baseboards should be considered to contain asbestos until proven otherwise.
Similarly, equipment such as exhaust stacks and metal-clad breaching, boilers, kilns, electrical
components and mechanical piping and ducting were not disassembled for assessment.
Subsequently, materials such as refractory, gaskets and other internal components should be
considered suspect ACM until sampled and proven otherwise. Roofing components and building
envelope materials such as window caulking or glazing were not sampled and should be
presumed asbestos-containing until proven otherwise.
15 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - 10 - 06-1113-212
Golder Associates
Analytical results reflect the sampled materials at the specific sample locations. Materials that
were visually similar in colour and texture were referenced to specific analyzed samples and were
considered to be of like composition and grouped as one homogeneous material.
Golder has relied on certain sample analysis results provided in documents supplied by TDSB
and prepared by others as detailed in Section 2.3 of this report.
Only suspect materials identified by TDSB and as detailed in Section 2.2 of this report were
sampled, with limited exceptions as determined by surveyors at the time of assessment.
2.11 General Recommendations
Should planned renovations involve the removal of materials confirmed or presumed to be
asbestos-containing, all appropriate precautions, as detailed in O. Reg. 278/05, must followed.
This survey was conducted to identify asbestos materials in accessible areas that require
monitoring as part of an Asbestos Management Program. It is possible that undiscovered ACMs
may be present within inaccessible locations such as wall cavities or above inaccessible ceilings.
Asbestos may also be present in materials that are inaccessible or not visible during a non-
invasive assessment. Materials such as adhesive mastic (may be used virtually anywhere) for
various items, including stick-up ceiling tiles, mirrors, etc., and packing compound in bell and
spigot joints of cast iron drain pipes may contain asbestos but are not easily confirmed without
causing significant damage to the associated materials. It is recommended that a more
comprehensive and invasive survey be conducted prior to any planned demolition or renovations
that involve entering previously inaccessible areas or inaccessible materials. If encountered
during future renovations or demolition, suspect materials should be treated as asbestos-
containing until proven otherwise.
If any ACM is present within the Site, an Asbestos Management Program (AMP) must be
maintained as per the requirements of Section 7 and 8 of O. Reg. 278/05. The AMP would
include provisions for regular assessments of all identified ACMs, appropriate procedures for
dealing with ACMs, and training, as appropriate, for all occupants who may come into contact
with ACMs.
16 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - 11 - 06-1113-212
Golder Associates
3.0 FINDINGS
3.1 Site-Specific Information
Information relating to the assessment of this Site is presented in Table 10:
Table 10 – Site-Specific Information
DUBLIN PUBLIC SCHOOL SAP ID# 3088
Approximate Bldg. Size (ft2): 44, 950 # of Levels (floors) including basement(s): 3
Region: CS Use: Leased Out
Year of Construction: 1948 Additions (years of Construction): None
Surveyed By: Golder Associates Ltd. Survey Date(s): Nov. 2, 5, 6, 2007
The findings of this assessment have been summarized in tabular form and are presented in the
attached appendices. Floor plans indicating sample locations and mapping of confirmed ACMs
are presented in Appendix I. Location numbers are typically situated on a grey dot representing
the centroid of the area. If two numbers are too close together to be shown clearly, one number
will be moved to make for clear identification. These numbers are easily identified as they are
not on top of a grey dot but situated very close to them.
Please note that all materials may not be mapped on these plans. Also note that Golder has used
the numbers on drawings provided by TDSB where possible and added new numbers if
appropriate numbers describing the location were not available. Some of the numbers provided
by TDSB were not used by Golder in this survey (multiple numbers in one area, etc.) and are not
presented on Golder’s drawings. Similarly, some area location/room numbers, typically for roofs
and a limited number of other areas, are referenced on the drawings but do not have a room or
floor plan associated with them.
The location, quantity and extent of ACM has been identified throughout the Site based on the
findings during Golder’s information review and Site assessment. Following the sampling
protocol outlined in Section 2.1 of this report, a total of 23 samples were obtained of materials
suspected of containing asbestos from the Site and submitted, along with a chain of custody, for
asbestos content analysis. This number represents the total number of samples that were
collected and/or analysed, which may have included multiple layers of a particular material,
where each layer was considered a sample.
17 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - 12 - 06-1113-212
Golder Associates
3.2 Confirmed And Presumed ACM
Confirmed and Presumed ACMs were identified within accessible areas of the Site. Floor plans
indicating sample locations and mapping of confirmed ACMs is presented in Appendix I.
Locations of historical samples, which were not collected during this assessment, are not shown
on the floor plans. Details of bulk sample analytical results (Laboratory Results) are presented in
Appendix II with listings of all ACMs (Summary of All Asbestos-Containing Materials, ACM &
PACM), presented in Appendix III. A listing of all materials identified, presented by location
(Room-by-Room Details: Summary Report by Location), is presented in Appendix IV.
4.0 RECOMMENDATIONS
Based on the findings of this assessment, actions have been assigned for each ACM identified.
Actions required for all ACMs are presented in the Summary of All Asbestos-Containing
Materials in Appendix III and the Room-by-Room Details, Summary Report by Location in
Appendix IV. All ACMs require routine inspection as indicated in TDSB Asbestos Management
Program and O. Reg. 278/05. All components (materials) identified in this report as ACM or
PACM should be considered as such wherever they are present within the building. Anyone
doing work at this site should be familiar with the contents of this report prior to conducting any
work that could disturb any building materials.
• An asbestos management program should be maintained for this facility as ACMs are
present;
• Inaccessible areas and spaces, such as above inaccessible ceilings or in wall or pipe
spaces, should be considered to contain asbestos until they can be accessed and properly
assessed;
• No Action Code 1 items requiring immediate remedial action were identified at this Site.
However, Priority 2 and 3 items were identified. Please refer to Appendix IV for details
and locations.
5.0 LIMITATIONS AND USE OF REPORT
The conclusions and recommendations contained in this assessment report are based upon
professional opinions with regard to the subject matter. These opinions are in accordance with
currently accepted industry practices for asbestos surveys and regulatory requirements for
sampling and identifying ACMs and are subject to the following inherent limitations:
18 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - 13 - 06-1113-212
Golder Associates
1. The data and findings presented in this report are valid as of the date of the investigation. The passage of time, manifestation of latent conditions or occurrence of future events may warrant further exploration at the Site, analysis of the data, and re-evaluation of the findings, observations, and conclusions expressed in this report.
2. The data reported and the findings, observations, conclusions, and recommendations expressed in this report are limited by the Scope of Work. The Scope of Work was defined by the request of the client, the time and budgetary constraints imposed by the client, and availability of access to the Site.
3. Because of the limitations stated above, the findings, observations, conclusions, and recommendations expressed by Golder in this report are not, and should not be, considered an opinion concerning compliance of any past or present owner or operator of the Site with any federal, provincial or local laws or regulations.
4. No warranty or guarantee, whether expressed or implied, is made with respect to the data or the reported findings, observations, and conclusions, which are based solely upon Site conditions in existence at the time of investigation.
5. Golder will not be responsible for any real or perceived decrease in a property value, its saleability or ability to gain financing through the reporting of information in this report.
6. Golder’s assessment reports present professional opinions and findings of a scientific and technical nature. While attempts were made to relate the data and findings to applicable environmental and occupational health & safety laws and regulations, the report shall not be construed to offer legal opinion or representations as to the requirements of, nor compliance with, environmental and occupational health & safety laws, rules, regulations or policies of federal, provincial, or local governmental agencies. Any use of the assessment report constitutes acceptance of the limits of Golder’s liability. Golder’s liability extends only to its client and not to other parties who may obtain this assessment report. Issues raised by the report should be reviewed by appropriate legal counsel.
6.0 CLOSURE
We trust that this report meets your requirements. If you have any questions regarding the
content of this report, please do not hesitate to contact the undersigned.
GOLDER ASSOCIATES LTD.
Christopher Nielsen, B.Sc., CCEP
Manager, Environmental Health and Safety Group
19 of 99
Toronto District School Board March 2008
SAP ID# 3088 – Dublin PS - 14 - 06-1113-212
Golder Associates
Andreas Wagner, M.Eng., CIH, ROH Principal, Director, Environmental Health & Safety CLN/AW/ N:\Active\2006\1113\06-1113-212 TDSB-Asbestos Survey-Toronto\Reports\9_Final_Report_PDF\3088\ProjectWork\Final Report\06-1113-212 RPT 08MAR26 3088 Dublin PS Final.doc
20 of 99
Golder Associates
ABBREVIATIONS AND DEFINITIONS
Abbreviations: SM, MED, LG Small, Medium and Large, respectively
<LOD Less than the Limit of Detection for the Analytical Method used. Typically 0.5% or 0.25%, or may indicate that no asbestos was identified in sample.
“ – “ Not applicable or no information required for this cell. When present under “Asbestos Type” column in Appendix IV, indicates that corresponding material is not considered to be asbestos-containing.
ACM Asbestos-Containing Material, defined as material that contains 0.5% or more asbestos by dry weight
FTG Fitting on a mechanical system including elbow, tee joint, valve, joint or end.
N/A Not Applicable
TBD To Be Determined
PACM Presumed Asbestos-Containing Material – must be treated as ACM until proven otherwise through bulk sample analysis
PLM Polarized Light Microscopy (asbestos identification procedure)
RND Round
SPF Spray-applied fireproofing
STR Straight section of pipe, duct or other mechanical system
VFT Vinyl Floor Tile
VSF Vinyl Sheet Flooring
Definitions:
Accessibility – A Accessible to anyone
Accessibility – B Accessible without a ladder
Accessibility – C Above eight feet and visible
Accessibility – D Above eight feet and not visible
Accessibility – E Inaccessible
Action Code – 1 Restrict access that is likely to cause a disturbance of the ACM debris and clean up ACM debris immediately
Action Code – 2 Restrict access to the area to persons using Type 2 precautions in accordance with O. Reg. 278/05 until the ACM debris has been cleaned up and the source of the debris has been stabilized or removed
Action Code – 3 Remove ACM in compliance with O. Reg. 278/05
Action Code – 4 Use Type 2 asbestos precautions in accordance with O. Reg. 278/05 when entry or access into an area is likely to disturb ACM
Action Code – 5 Repair ACM found in fair condition and not likely to be damaged again, or disturbed by normal use of the area or room
Action Code – 6 Maintain routine inspection of ACM
Asbestos Fibrous silicate materials including actinolite, amosite, anthophyllite, chrysotile, crocidolite and tremolite as defined in O. Reg. 278/05, s.1(2).
Asbestos I Primary type, by %, of asbestos present in a sample, as presented in the Laboratory Results Appendix
Asbestos II Secondary type, by percentage, of asbestos present in a sample, as presented in the Laboratory Results Appendix
Component Construction material used in building which is deemed to be a homogeneous material (consistent in colour and texture) and is treated as a unit throughout its extent within the building (e.g., plaster, concrete, or parging cement)
Homogeneous Material Homogeneous Materials are materials that are uniform in colour and texture and includes the material throughout its full extent, even if its occurrence is not contiguous or physically connected.
To Be Determined To be determined (TBD) through the inspection and sampling protocol, as required by O.Reg 278/05, for those areas that were not accessible during the initial survey. ACM is presumed to be present unless proven otherwise through sampling and accredited lab analysis and reports.
Not Applicable System is not present or no suspect material is associated with the system at the location
Not Found System or suspect material associated with it was not found to be present
Not Tested or
Sample Not Analyzed Previous sample of this homogeneous material was found to be positive for asbestos; therefore further analysis is not required.
22 of 99
Base Data - CANMAP v2005.4Datum: NAD 83 Projection: UTM Zone 17N
REFERENCE
SITE LOCATION PLAN3088 - DUBLIN PS819 SHEPPARD AVENUE WESTTORONTO, ONTARIO
FIGURE: SPPROJECT No. 06-1113-212PROJECT
TITLE
ASBESTOS SURVEY - CENTRAL SERVICES REGIONTORONTO DISTRICT SCHOOL BOARD
"
REINER RD
SEARLE AVE
CODSELL AVE
WATERLOO AVE
BRIGHTON AVE
SHEPPARD AVE W
ACTON AVE
MCALLISTER RD
GODDARD ST
ELDER ST
MAXWELL ST
COCKSFIELD AVE
WILMINGTON AVE
FAYWOOD BLVD
ALEXIS BLVD
ALMORE AVE
BRYANT ST
BAINBRIDGE AVE
WILSON HEIGHTS BLVD
COMBE AVE
SANDALE GDNS
HARLOCK BLVD
GRANITE ST
NORCROSS RD
MARWILL ST
BOWRING WALK
DUNSMORE GDNS
SHAFTESBURY ST
FINDLAY BLVD
AMBASSADOR PL
AMOS CRES
BAINTREE CRT
LIBERATO CRT
DEHAVILAND STCOCKSFIELD AVE
³
LEGEND0 500 1,000 1,500250
Feet" Site Location
Express WayArterial RoadLocal road
SITE LOCATION
24 of 99
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!
!
!
!
!!
!
!!
!
!
!
!
!
A
A
A
A
69432-1
69425-1 69432
69431
6942869427
69425
69424
69423
69421
3088-1-5005-008-05
3088-1-5005-008-04
3088-1-5005-008-01,02,03
3088-1-3006-015-01,02,03
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!
!
!
!
!!
!
!!
!
!
!
!
!
A
A
A
A
69432-1
69425-1 69432
69431
6942869427
69425
69424
69423
69421
3088-1-5005-008-05
3088-1-5005-008-04
3088-1-5005-008-01,02,03
3088-1-3006-015-01,02,03
PROJECT
TITLE
Drawings based on plans provided by the Toronto District School Board.REFERENCE
0 2512.5Feet
G:\P
rojec
ts\20
06\06
-1113
-212_
TDSB
\GIS
\MXD
s\Draf
t\auto
\batch
\A_3
088_
1_-1.
mxd
ACM AND SAMPLE LOCATION PLANBASEMENT3088 - DUBLIN PS819 SHEPPARD AVENUE WESTTORONTO, ONTARIO
ASBESTOS SURVEY - CENTRAL SERVICES REGIONTORONTO DISTRICT SCHOOL BOARD FIGURE: BA
PROJECT No. 06-1113-212
1. This drawing is schematic only and is to be read in conjunction with theaccompanying text.2. Some numbers provided by the Toronto District School Board have not been used.
NOTESRoof ID: 68443Exterior ID: 68443-1
³N
Description of Asbestos-Containing MaterialsPipe Insulation
!!
!!
!!
!!
!!
!!
!!
!!
!!
!!Mechanical System,Pipe Insulation
3.Only sampled materials and/or confirmed ACM is shown on the drawing. Shaded areas represent the presence of one or more Asbestos-Containing Material (ACM) component(s). Cross reference to Appendix IV -“Room by Room Details - Summary Report By Location” for specifics.
LEGENDLEGEND!A
!A
Sample #Positive Sample LocationSample #Negative Sample Location Not Tested Sample Location Sample #!A
Location/Room!
Location Description69421 Washroom - Girls, 11069423 Electrical Room, 10269424 Classroom, 10369425 Boiler / Furnace Room, Boiler
Room/10869425-1 Corridor, Corridor 101
69427 Storage Room, 10969428 Caretakers Office, Caretaker/10769431 Classroom, 10469432 Washroom - Boys, 106
69432-1 Main Water Entry, 105
Sample # Location Component # Description3088-1-3006-015-01,02,03
69424 15 1x1 uniform small holes Glue On Ceiling Tiles
3088-1-5005-008-01,02,03
69425 8 Cellulose On Straight Run Pipe
3088-1-5005-008-04 69427 8 Cellulose On Straight Run Pipe3088-1-5005-008-05 69432 8 Cellulose On Straight Run Pipe
25 of 99
!
!
!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
!
!
!
!
!
!
A
A
A
69220-1
69450-1
69443-1
69440-1
69449-169451-1
69219-1
69442-1
6945269451 69450
69449
69448
6944769446
69445
69444
6944369442
69441
6944069439
69438
69437
69436
6943569434
6923769236
69235
69234
69233
69232
69231
6923069229
69228 69227
69226
69225
69223
69222
69221
69220
69219
69218
69217
69216
3088-1-3006-024-01,02,03
3088-1-3006-045-01,02,03
3088-1-5006-046-01,02,03!
!
!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
!
!
!
!
!
!
A
A
A
69220-1
69450-1
69443-1
69440-1
69449-169451-1
69219-1
69442-1
6945269451 69450
69449
69448
6944769446
69445
69444
6944369442
69441
6944069439
69438
69437
69436
6943569434
6923769236
69235
69234
69233
69232
69231
6923069229
69228 69227
69226
69225
69223
69222
69221
69220
69219
69218
69217
69216
3088-1-3006-024-01,02,03
3088-1-3006-045-01,02,03
3088-1-5006-046-01,02,03
PROJECT
TITLE
Drawings based on plans provided by the Toronto District School Board.REFERENCE
0 25 50 75 10012.5Feet
G:\P
rojec
ts\20
06\06
-1113
-212_
TDSB
\GIS
\MXD
s\Draf
t\auto
\batch
\A_3
088_
1_1.m
xd
ACM AND SAMPLE LOCATION PLANFLOOR 13088 - DUBLIN PS819 SHEPPARD AVENUE WESTTORONTO, ONTARIO
ASBESTOS SURVEY - CENTRAL SERVICES REGIONTORONTO DISTRICT SCHOOL BOARD FIGURE: 1
PROJECT No. 06-1113-212
1. This drawing is schematic only and is to be read in conjunction with theaccompanying text.2. Some numbers provided by the Toronto District School Board have not been used.
NOTESRoof ID: 68443Exterior ID: 68443-1
³N
Description of Asbestos-Containing MaterialsPipe Insulation
3.Only sampled materials and/or confirmed ACM is shown on the drawing. Shaded areas represent the presence of one or more Asbestos-Containing Material (ACM) component(s). Cross reference to Appendix IV -“Room by Room Details - Summary Report By Location” for specifics.
LEGENDLEGEND!A
!A
Sample #Positive Sample LocationSample #Negative Sample Location Not Tested Sample Location Sample #!A
Location/Room!
Location Description69216 Office / Admin. Area, 21769217 Classroom, 22469218 Classroom, 21969219 Corridor, E-W outside Stair C
69219-1 Corridor, N-S outside room 21269220 Classroom, 220
69220-1 Stairwell, Stair B69221 Office / Admin. Area, 22169222 Classroom, 22269223 Classroom, 22369225 Kitchen, 22969226 Gym, Auditorium/22869227 Stairwell, Exit 22569228 Stairwell, Stair C69229 Washroom, adjoining room 22369230 Washroom, 222C69231 Vestibule, 222A69232 Corridor, N-S between exit 101 and
room 20969233 Main Office, Office69234 Storage Room, PE Equipment/22769235 Storage Room, 228A69236 Washroom, adjoining room 22369237 Washroom, 222B69434 Vestibule, 10169435 Office / Admin. Area, 10569436 Office / Admin. Area, 23269437 Storage Room, adjoining room 23269438 Office / Admin. Area, 23169439 Vestibule, between rooms 231 and 23269440 Classroom, 208
69440-1 Stairwell, west of corridor 20369441 Classroom, 20469442 Office / Admin. Area, adjacent to
room 20869442-1 Corridor, Corridor 203
69443 Classroom, 20669443-1 Stairwell, Stair A
69444 Classroom, 20569445 Office / Admin. Area, 20969446 Kitchen, 23069447 Classroom, 21169448 Classroom, 21269449 Washroom - Girls, 213A
69449-1 Vestibule, 21369450 Washroom - Boys, 216A
69450-1 Vestibule, 21669451 Washroom, Staff/215
69451-1 Maintenance Room, pipe chaseadjoining room 215
69452 Caretakers Room, 214 Sample # Location Component # Description3088-1-3006-024-01,02,03
69440-1 24 1x1 asymmetric medium and large holes Glue On Ceiling Tiles
3088-1-3006-045-01,02,03
69219-1 45 1x1 random small fissures and pinholes Glue On Ceiling Tiles
3088-1-5006-046-01,02,03
69219 46 Cellulose & Tar Paper On Straight Run Pipe
26 of 99
!!
!!
!
!!
!!
!
!!
!!
!
!!
!!
!
!!
!!
!
!!
!!
!
!!
!!
!
!!
!!
!
!!
!
!
!
!
!
!
!
!
!
! !
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
A
A
69248-1
69244-169242-1
69241-1
69462-1
69253-1
69454-1
69464
69463
69462
6946169460
69459
69458
69457
6945669455
69454
69453
69261
6926069259
69258
69257
69256
69255
69254
69253
69252
69251
6925069249
69248
69247
6924669245
69244
69243
69242
69241
692406923969238
3088-1-3006-035-01,02,03
3088-1-3006-039-01,02,03
!!
!!
!
!!
!!
!
!!
!!
!
!!
!!
!
!!
!!
!
!!
!!
!
!!
!!
!
!!
!!
!
!!
!
!
!
!
!
!
!
!
!
! !
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
A
A
69248-1
69244-169242-1
69241-1
69462-1
69253-1
69454-1
69464
69463
69462
6946169460
69459
69458
69457
6945669455
69454
69453
69261
6926069259
69258
69257
69256
69255
69254
69253
69252
69251
6925069249
69248
69247
6924669245
69244
69243
69242
69241
692406923969238
3088-1-3006-035-01,02,03
3088-1-3006-039-01,02,03
PROJECT
TITLE
Drawings based on plans provided by the Toronto District School Board.REFERENCE
0 25 50 75 10012.5Feet
G:\P
rojec
ts\20
06\06
-1113
-212_
TDSB
\GIS
\MXD
s\Draf
t\auto
\batch
\A_3
088_
1_2.m
xd
ACM AND SAMPLE LOCATION PLANFLOOR 23088 - DUBLIN PS819 SHEPPARD AVENUE WESTTORONTO, ONTARIO
ASBESTOS SURVEY - CENTRAL SERVICES REGIONTORONTO DISTRICT SCHOOL BOARD FIGURE: 2
PROJECT No. 06-1113-212
1. This drawing is schematic only and is to be read in conjunction with theaccompanying text.2. Some numbers provided by the Toronto District School Board have not been used.
NOTESRoof ID: 68443Exterior ID: 68443-1
³N
Description of Asbestos-Containing MaterialsPipe Insulation
!!
!!
!!
!!
!!
!!
!!
!!
!!
!!Mechanical System,Pipe Insulation
3.Only sampled materials and/or confirmed ACM is shown on the drawing. Shaded areas represent the presence of one or more Asbestos-Containing Material (ACM) component(s). Cross reference to Appendix IV -“Room by Room Details - Summary Report By Location” for specifics.
LEGENDLEGEND!A
!A
Sample #Positive Sample LocationSample #Negative Sample Location Not Tested Sample Location Sample #!A
Location/Room!
Location Description69238 Storage Room, Stockroom/32569239 Washroom, Staff/32469240 Kitchen, 323A69241 Staff Room, Staff/323
69241-1 Corridor, outside room 32469242 Classroom, 305
69242-1 Stairwell, west of corridor 30169243 Classroom, 32669244 Teachers Workroom, Tutorial/304
69244-1 Corridor, Corridor 30169245 Washroom, 304A69246 Caretakers Room, 30369247 Classroom, 32769248 Classroom, 302
69248-1 Stairwell, Stair A69249 Caretakers Room, 30869250 Washroom - Girls, 30769251 Washroom - Boys, 31069252 Classroom, 31169253 Corridor, N-S outside room 312
69253-1 Corridor, E-W outside Stair C69254 Classroom, 31269255 Washroom, 314A69256 Teachers Workroom, 31469257 Hub Room, 31569258 Photocopy Room, 314B69259 Office / Admin. Area, 31769260 Caretakers Room, 31669261 Office / Admin. Area, Staff/318B69453 Teachers Workroom, 318A69454 Library, 318
69454-1 Stairwell, Stair C69455 Corridor, E-W outside room 31869456 Storage Room, 318C69457 Mechanical Room, 318D69458 Library, 31869459 Classroom, 31969460 Storage Room, 32069461 Mechanical Room, 32269462 Classroom, A321
69462-1 Stairwell, Stair C69463 Empty Room, 31369464 Computer Room, adjoining room 314
Sample # Location Component # Description3088-1-3006-035-01,02,03
69241 35 1x1 large fissures and pinholes Glue On Ceiling Tiles
3088-1-3006-039-01,02,03
69458 39 1x1 random medium and large holes Glue On Ceiling Tiles
27 of 99
Date: 4/15/2008
Facility : 3088 - Dublin PS
Client : Toronto District School Board
Job Number : 06-1113-212Laboratory Results
Appendix II
Page: 1Golder Associates
Refer to Attachment for Definitions and Abbreviations
45 1x1 random small fissures and pinholes Glue On Ceiling Tiles
3088-1-3006-045-03
020706987-0015
2047589 69219-1 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
39 1x1 random medium and large holes Glue On Ceiling Tiles
3088-1-3006-039-03
020706987-0012
2047589 69458 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
45 1x1 random small fissures and pinholes Glue On Ceiling Tiles
3088-1-3006-045-01
020706987-0013
2047589 69219-1 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
45 1x1 random small fissures and pinholes Glue On Ceiling Tiles
3088-1-3006-045-02
020706987-0014
2047589 69219-1 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
39 1x1 random medium and large holes Glue On Ceiling Tiles
3088-1-3006-039-02
020706987-0011
2047589 69458 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
15 1x1 uniform small holes Glue On Ceiling Tiles
3088-1-3006-015-03
020706987-0003
2047589 69424 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
20 Preformed Block On Straight Run Pipe
3088-1-0000-20-01-H
3088-1-0000-20-01-H
N/A N/A N/A 50 Chrysotile N/A Not Tested N/A Historical Data - TDSB Central Files
24 1x1 asymmetric medium and large holes Glue On Ceiling Tiles
3088-1-3006-024-01
020706987-0004
2047589 69440-1 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
11 Aircell On Straight Run Pipe 3088-1-0000-11-01-H
3088-1-0000-11-01-H
N/A N/A N/A 75 Chrysotile N/A Not Tested N/A Historical Data - TDSB Central Files
15 1x1 uniform small holes Glue On Ceiling Tiles
3088-1-3006-015-01
020706987-0001
2047589 69424 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
15 1x1 uniform small holes Glue On Ceiling Tiles
3088-1-3006-015-02
020706987-0002
2047589 69424 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
35 1x1 large fissures and pinholes Glue On Ceiling Tiles
3088-1-3006-035-02
020706987-0008
2047589 69241 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
35 1x1 large fissures and pinholes Glue On Ceiling Tiles
3088-1-3006-035-03
020706987-0009
2047589 69241 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
39 1x1 random medium and large holes Glue On Ceiling Tiles
3088-1-3006-039-01
020706987-0010
2047589 69458 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
24 1x1 asymmetric medium and large holes Glue On Ceiling Tiles
3088-1-3006-024-02
020706987-0005
2047589 69440-1 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
24 1x1 asymmetric medium and large holes Glue On Ceiling Tiles
3088-1-3006-024-03
020706987-0006
2047589 69440-1 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
35 1x1 large fissures and pinholes Glue On Ceiling Tiles
3088-1-3006-035-01
020706987-0007
2047589 69241 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
Building: 1 (Dublin PS)
Component Sample # Lab Sample #
Lab Report Number
Location Test Method
Asbestos I %
Asbestos I Type
Asbestos II %
Asbestos II Type
LOD %
Additional Comments
29 of 99
Date: 4/15/2008
Facility : 3088 - Dublin PS
Client : Toronto District School Board
Job Number : 06-1113-212Laboratory Results
Appendix II
Page: 2Golder Associates
Refer to Attachment for Definitions and Abbreviations
8 Cellulose On Straight Run Pipe 3088-1-5005-008-02
020706987-0017
2047589 69425 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
8 Cellulose On Straight Run Pipe 3088-1-5005-008-01
020706987-0016
2047589 69425 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
7 Parging Cement On Fittings 3088-1-5001-007-01-H
3088-1-5001-007-01-H
3088-1-5001-007-01-H
69425 N/A 75 Chrysotile N/A Not Tested N/A Historical Data - TDSB Central Files
8 Cellulose On Straight Run Pipe 3088-1-5005-008-03
020706987-0018
2047589 69425 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
9 Parging Cement 3088-1-7005-009-01-H
3088-1-7005-009-01-H
3088-1-7005-009-01-H
69425 N/A 75 Chrysotile N/A Not Tested N/A Historical Data - TDSB Central Files
8 Cellulose On Straight Run Pipe 3088-1-5005-008-05
020706987-0020
2047589 69432 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
8 Cellulose On Straight Run Pipe 3088-1-5005-008-04
020706987-0019
2047589 69427 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
46 Cellulose & Tar Paper On Straight Run Pipe
3088-1-5006-046-02
020706987-0022
2047589 69219 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
46 Cellulose & Tar Paper On Straight Run Pipe
3088-1-5006-046-01
020706987-0021
2047589 69219 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
48 Parging Cement On Seam, Joints And Pins
3088-1-0000-48-01-H
3088-1-0000-48-01-H
N/A N/A N/A 50 Chrysotile N/A Not Tested N/A Historical Data - TDSB Central Files
46 Cellulose & Tar Paper On Straight Run Pipe
3088-1-5006-046-03
020706987-0023
2047589 69219 PLM <LOD No Asbestos Detected
N/A Not Tested 0.5 N/A
Building: 1 (Dublin PS)
Component Sample # Lab Sample #
Lab Report Number
Location Test Method
Asbestos I %
Asbestos I Type
Asbestos II %
Asbestos II Type
LOD %
Additional Comments
30 of 99
Date: 4/15/2008
Facility : 3088 - Dublin PS
Client : Toronto District School Board
Job Number : 06-1113-212Summary of All Asbestos-Containing Materials
Appendix III - ACM & PACM
Golder Associates Page: 1
Refer to Attachment for Definitions and Abbreviations
18 Plaster No 69219-1;69220-1;69223;69454-1 WALL 102.00 square feet C Yes N/A Presumed 6
17 12" x 12" Vinyl Floor Tile No 69246;69260 FLOOR 33.00 square feet B Yes N/A Presumed 6
17 12" x 12" Vinyl Floor Tile No 69218;69220;69222;69238;69240;69241;69241-1;69242;69243;69244;69247;69248;69256;69258;69261;69424;69440;69441;69442;69443;69446;69447;69448;69453;69454;69455;69458;69460
FLOOR 14,763.00 square feet A Yes N/A Presumed 6
13 Bell & Spigot Joints Yes 69428 PIPING SYSTEMS 2 each C Yes N/A Presumed 6
13 Bell & Spigot Joints Yes 69246;69451-1;69461 PIPING SYSTEMS 31 each B Yes N/A Presumed 6
13 Bell & Spigot Joints Yes 68443-1;69234;69421;69432;69442 PIPING SYSTEMS 26 each A Yes N/A Presumed 6
12 Window Sealers Yes 69428 OTHER 2 each B Yes N/A Presumed 6
12 Window Sealers Yes 69217;69218;69219;69219-1;69220;69220-1;69222;69223;69225;69226;69227;69231;69233;69234;69238;69240;69241;69241-1;69242;69243;69244;69247;69248;69248-1;69250;69251;69252;69253;69254;69258;69261;69421;69424;69431;69432;69434;69435;69436;69437;69438;69440;69441;69442;69443;69444;69445;69446;69447;69448;69449;69454;69454-1;69455;69458;69459;69460;69462;69462-1
OTHER 316 each A Yes N/A Presumed 6
12 Window Sealers Yes 69216;69221;69242-1;69259;69457 OTHER 13 each C Yes N/A Presumed 6
11 Aircell On Straight Run Pipe Yes 69428 PIPING SYSTEMS 10.00 linear feet B Yes 75 Chrysotile 6
11 Aircell On Straight Run Pipe Yes 69427 PIPING SYSTEMS 10.00 linear feet A Yes 75 Chrysotile 3
11 Aircell On Straight Run Pipe Yes 69421 PIPING SYSTEMS 30.00 linear feet C Yes 75 Chrysotile 6
11 Aircell On Straight Run Pipe Yes 69219;69223 PIPING SYSTEMS 210.00 linear feet D No 75 Chrysotile 6
10 Other Suspect Piping Yes 69451-1 PIPING SYSTEMS 100.00 linear feet B Yes N/A Presumed 6
10 Other Suspect Piping Yes 69424;69425;69443 PIPING SYSTEMS 108.00 linear feet C Yes N/A Presumed 6
10 Other Suspect Piping Yes 69223;69229;69442 PIPING SYSTEMS 65.00 linear feet D No N/A Presumed 6
Building: 1 (Dublin PS)
Component Description of Material Friable Locations System Quantity Units Accessibility Visible Asbestos % Type Action Code
Component Details Asbestos Content
32 of 99
Date: 4/15/2008
Facility : 3088 - Dublin PS
Client : Toronto District School Board
Job Number : 06-1113-212Summary of All Asbestos-Containing Materials
Appendix III - ACM & PACM
Golder Associates Page: 2
Refer to Attachment for Definitions and Abbreviations
34 Drywall And Joint Compound No 69216;69229;69230;69235;69236;69237;69238;69239;69240;69255;69257;69259;69260;69449;69450;69451;69456
CEILING 1,398.00 square feet C Yes N/A Presumed 6
33 Drywall And Joint Compound No 69246 WALL 60.00 square feet B Yes N/A Presumed 6
33 Drywall And Joint Compound No 69218;69220;69243;69244;69245;69247;69248;69261;69453;69454
WALL 1,139.00 square feet A Yes N/A Presumed 6
32 Vinyl Countertop Yes 69225;69242;69243;69244;69247;69248;69252;69254;69448;69459;69462
OTHER 250.00 square feet A Yes N/A Presumed 6
30 Vinyl Sheet Flooring Yes 69225;69242;69243;69245;69247;69248;69445 FLOOR 1,997.00 square feet A Yes N/A Presumed 6
29 Transite Asbestos Cement No 69232;69434 WALL 80.00 square feet A Yes N/A Presumed 6
29 Transite Asbestos Cement No 69222;69223 WALL 210.00 square feet E No N/A Presumed 6
29 Transite Asbestos Cement No 68443-1;69227 WALL 720.00 square feet C Yes N/A Presumed 6
27 Horizontal Plaster Bulkhead No 69442 OTHER 60.00 square feet A Yes N/A Presumed 6
27 Horizontal Plaster Bulkhead No 69440;69441;69443;69444 OTHER 560.00 square feet C Yes N/A Presumed 6
26 Plaster No 69442 CEILING 187.00 square feet D No N/A Presumed 6
26 Plaster No 69220-1;69253 CEILING 127.00 square feet A Yes N/A Presumed 6
21 9" x 9" Vinyl Floor Tile No 69216;69217;69221;69223;69233;69235;69252;69254;69255;69256;69257;69258;69259;69431;69435;69436;69437;69438;69439;69444;69456;69459;69460;69462;69463;69464
FLOOR 8,658.00 square feet A Yes N/A Presumed 3
20 Preformed Block On Straight Run Pipe
Yes 69432 PIPING SYSTEMS 40.00 linear feet A Yes 50 Chrysotile 6
20 Preformed Block On Straight Run Pipe
Yes 69421 PIPING SYSTEMS 30.00 linear feet C Yes 50 Chrysotile 6
18 Plaster No 69260 WALL 95.00 square feet B Yes N/A Presumed 6
18 Plaster No 69229;69230;69236;69237;69238;69239;69240;69241;69241-1;69242-1;69244;69244-1;69248-1;69253;69253-1;69255;69256;69257;69258;69425-1;69440;69440-1;69441;69442;69442-1;69443;69443-1;69444;69463;69464
WALL 10,903.00 square feet A Yes N/A Presumed 6
Building: 1 (Dublin PS)
Component Description of Material Friable Locations System Quantity Units Accessibility Visible Asbestos % Type Action Code
Component Details Asbestos Content
33 of 99
Date: 4/15/2008
Facility : 3088 - Dublin PS
Client : Toronto District School Board
Job Number : 06-1113-212Summary of All Asbestos-Containing Materials
Appendix III - ACM & PACM
Golder Associates Page: 3
Refer to Attachment for Definitions and Abbreviations
9 Parging Cement Yes 69425 MECHANICAL EQUIPMENT
150.00 square feet B Yes 75 Chrysotile 6
7 Parging Cement On Fittings Yes 69424;69425-1;69440;69442-1;69443;69444 PIPING SYSTEMS 58 each C Yes 75 Chrysotile 6
7 Parging Cement On Fittings Yes 69423;69425;69428;69432-1;69457 PIPING SYSTEMS 192 each B Yes 75 Chrysotile 6
7 Parging Cement On Fittings Yes 69221;69234;69421;69427;69431;69432;69440-1;69441;69442;69443-1;69456
PIPING SYSTEMS 264 each A Yes 75 Chrysotile 6
7 Parging Cement On Fittings Yes 69219;69223;69229;69237;69455 PIPING SYSTEMS 62 each D No 75 Chrysotile 2
52 Built Up Membrane Roof No 68443 FLOOR 22,000.00 square feet B Yes N/A Presumed 6
48 Parging Cement On Seam, Joints And Pins
Yes 69457 DUCTWORK 25.00 square feet C Yes 50 Chrysotile 6
47 Perforated Transite Asbestos Cement
No 69457 WALL 180.00 square feet B Yes N/A Presumed 6
43 Transite Asbestos Cement No 68443-1;69227 CEILING 400.00 square feet C Yes N/A Presumed 6
42 Plaster Column Enclosure No 69223 STRUCTURE 36.00 square feet A Yes N/A Presumed 6
40 Vertical Drywall Bulkhead No 69453;69458 OTHER 85.00 square feet A Yes N/A Presumed 6
38 Horizontal Drywall Bulkhead No 69257 OTHER 20.00 square feet C Yes N/A Presumed 6
36 Vertical Plaster Bulkhead No 69241;69463 OTHER 35.00 square feet A Yes N/A Presumed 6
Building: 1 (Dublin PS)
Component Description of Material Friable Locations System Quantity Units Accessibility Visible Asbestos % Type Action Code
Component Details Asbestos Content
34 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 1Golder Associates
Refer to Attachment for Definitions and Abbreviations
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Concrete 3 - - - - - - - - - - - -
CEILING Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 10 0 0 0 10 each 75 Chrysotile Yes Yes B 6
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR Concrete 3 - - - - - - - - - - - -
WALL Concrete 3 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Basement: 69423 Quantity/Condition Total Location Details: Electrical Room, 102 (Open)
CEILING Not Found 1 - - - - - - - - - - - -
STRUCTURE Concrete 3 - - - - - - - - - - - -
PIPING SYSTEMS Aircell On Straight Run Pipe 11 30.00 0.00 0.00 0.00 30.00 linear feet 75 Chrysotile Yes Yes C 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
FLOOR Concrete 3 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
WALL Concrete 3 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 90 0 0 0 90 each 75 Chrysotile Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 1 0 0 0 1 each - Presumed Yes Yes A 6
PIPING SYSTEMS Bell & Spigot Joints 13 1 0 0 0 1 each - Presumed Yes Yes A 6
PIPING SYSTEMS Preformed Block On Straight Run Pipe 20 30.00 0.00 0.00 0.00 30.00 linear feet 50 Chrysotile Yes Yes C 6
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Basement: 69421 Quantity/Condition Total Location Details: Washroom - Girls, 110 (Open)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
36 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 2Golder Associates
Refer to Attachment for Definitions and Abbreviations
CEILING Not Found 1 - - - - - - - - - - - -
WALL Brick/Block/Concrete 5 - - - - - - - - - - - -
FLOOR Concrete 3 - - - - - - - - - - - -
Location: Basement: 69425 Quantity/Condition Total Location Details: Boiler / Furnace Room, Boiler Room/108 (Open)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
PIPING SYSTEMS Parging Cement On Fittings 7 7 0 0 0 7 each 75 Chrysotile Yes Yes C 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING 1x1 uniform small holes Glue On Ceiling Tiles 15 - - - - - - <LOD No Asbestos Detected
- - - -
CEILING New Ceiling Tile 16 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 788.00 0.00 0.00 0.00 788.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
WALL Concrete 3 - - - - - - - - - - - -
DUCTWORK Uninsulated 2 - - - - - - - - - - - -
PIPING SYSTEMS Other Suspect Piping 10 3.00 0.00 0.00 0.00 3.00 linear feet - Presumed Yes Yes C 6
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Basement: 69424 Quantity/Condition Total Location Details: Classroom, 103 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
Location: Basement: 69423 Quantity/Condition Total Location Details: Electrical Room, 102 (Open)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
37 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 3Golder Associates
Refer to Attachment for Definitions and Abbreviations
PIPING SYSTEMS Parging Cement On Fittings 7 35 0 0 0 35 each 75 Chrysotile Yes Yes C 6
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
WALL Plaster 18 50.00 0.00 0.00 0.00 50.00 square feet
- Presumed No Yes A 6
FLOOR Concrete 3 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
STRUCTURE Concrete 3 - - - - - - - - - - - -
CEILING Not Found 1 - - - - - - - - - - - -
Location: Basement: 69425-1 Quantity/Condition Total Location Details: Corridor, Corridor 101 (Open)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 120 0 0 0 120 each 75 Chrysotile Yes Yes B 6
PIPING SYSTEMS Other Suspect Piping 10 100.00 0.00 0.00 0.00 100.00 linear feet - Presumed Yes Yes C 6
STRUCTURE Concrete 3 - - - - - - - - - - - -
DUCTWORK Uninsulated 2 - - - - - - - - - - - -
PIPING SYSTEMS Cellulose On Straight Run Pipe 8 - - - - - - <LOD No Asbestos Detected
- - - -
OTHER Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Parging Cement 9 150.00 0.00 0.00 0.00 150.00 square feet
75 Chrysotile Yes Yes B 6
MECHANICAL EQUIPMENT
Uninsulated 2 - - - - - - - - - - - -
Comments: Includes location 69426.
Location: Basement: 69425 Quantity/Condition Total Location Details: Boiler / Furnace Room, Boiler Room/108 (Open)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
38 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 4Golder Associates
Refer to Attachment for Definitions and Abbreviations
CEILING Not Found 1 - - - - - - - - - - - -
STRUCTURE Concrete 3 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR Concrete 3 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
WALL Concrete 3 - - - - - - - - - - - -
PIPING SYSTEMS Cellulose On Straight Run Pipe 8 - - - - - - <LOD No Asbestos Detected
- - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 25 0 0 0 25 each 75 Chrysotile Yes Yes B 6
PIPING SYSTEMS Aircell On Straight Run Pipe 11 10.00 0.00 0.00 0.00 10.00 linear feet 75 Chrysotile Yes Yes B 6
PIPING SYSTEMS Bell & Spigot Joints 13 2 0 0 0 2 each - Presumed Yes Yes C 6
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Basement: 69428 Quantity/Condition Total Location Details: Caretakers Office, Caretaker/107 (Open)
STRUCTURE Concrete 3 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
CEILING Not Found 1 - - - - - - - - - - - -
FLOOR Concrete 3 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
PIPING SYSTEMS Cellulose On Straight Run Pipe 8 - - - - - - <LOD No Asbestos Detected
- - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Aircell On Straight Run Pipe 11 9.00 0.00 1.00 0.00 10.00 linear feet 75 Chrysotile Yes Yes A 3
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 20 0 0 0 20 each 75 Chrysotile Yes Yes A 6
Location: Basement: 69427 Quantity/Condition Total Location Details: Storage Room, 109 (Open)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
39 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 5Golder Associates
Refer to Attachment for Definitions and Abbreviations
FLOOR Concrete 3 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Concrete 3 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
Location: Basement: 69432 Quantity/Condition Total Location Details: Washroom - Boys, 106 (Open)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Uninsulated 2 - - - - - - - - - - - -
CEILING New Ceiling Tile 16 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING 1x1 uniform small holes Glue On Ceiling Tiles 15 - - - - - - <LOD No Asbestos Detected
- - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 772.00 0.00 0.00 0.00 772.00 square feet
- Presumed No Yes A 6
WALL Concrete 3 - - - - - - - - - - - -
OTHER Window Sealers 12 5 0 0 0 5 each - Presumed Yes Yes A 6
PIPING SYSTEMS Parging Cement On Fittings 7 20 0 0 0 20 each 75 Chrysotile Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Basement: 69431 Quantity/Condition Total Location Details: Classroom, 104 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes B 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Basement: 69428 Quantity/Condition Total Location Details: Caretakers Office, Caretaker/107 (Open)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
40 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 6Golder Associates
Refer to Attachment for Definitions and Abbreviations
STRUCTURE Concrete 3 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 12 0 0 0 12 each 75 Chrysotile Yes Yes B 6
WALL Concrete 3 - - - - - - - - - - - -
FLOOR Concrete 3 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Basement: 69432-1 Quantity/Condition Total Location Details: Main Water Entry, 105 (Open)
PIPING SYSTEMS Preformed Block On Straight Run Pipe 20 40.00 0.00 0.00 0.00 40.00 linear feet 50 Chrysotile Yes Yes A 6
PIPING SYSTEMS Bell & Spigot Joints 13 7 0 0 0 7 each - Presumed Yes Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Not Found 1 - - - - - - - - - - - -
STRUCTURE Concrete 3 - - - - - - - - - - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 4 0 0 0 4 each - Presumed Yes Yes A 6
PIPING SYSTEMS Parging Cement On Fittings 7 50 0 0 0 50 each 75 Chrysotile Yes Yes A 6
PIPING SYSTEMS Cellulose On Straight Run Pipe 8 - - - - - - <LOD No Asbestos Detected
- - - -
Comments: Includes locations 69430, 69433, and 69429.
Location: Basement: 69432 Quantity/Condition Total Location Details: Washroom - Boys, 106 (Open)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
41 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 7Golder Associates
Refer to Attachment for Definitions and Abbreviations
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 706.00 0.00 0.00 0.00 706.00 square feet
- Presumed No Yes A 6
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
Location: Floor 1: 69217 Quantity/Condition Total Location Details: Classroom, 224 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
WALL Brick 22 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Drywall And Joint Compound 34 123.00 0.00 0.00 0.00 123.00 square feet
- Presumed No Yes C 6
FLOOR 9" x 9" Vinyl Floor Tile 21 123.00 0.00 0.00 0.00 123.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes C 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69216 Quantity/ConditionTotal
Location Details: Office / Admin. Area, 217 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
42 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 8Golder Associates
Refer to Attachment for Definitions and Abbreviations
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
Location: Floor 1: 69219 Quantity/ConditionTotal
Location Details: Corridor, E-W outside Stair C (Limited view above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
STRUCTURE Not Found 1 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
WALL Drywall And Joint Compound 33 50.00 0.00 0.00 0.00 50.00 square feet
- Presumed No Yes A 6
WALL Concrete Block 4 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 845.00 0.00 0.00 0.00 845.00 square feet
- Presumed No Yes A 6
OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69218 Quantity/Condition Total Location Details: Classroom, 219 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access beneath sink due to storage.
Location: Floor 1: 69217 Quantity/Condition Total Location Details: Classroom, 224 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
43 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 9Golder Associates
Refer to Attachment for Definitions and Abbreviations
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
CEILING 1x1 random small fissures and pinholes Glue On Ceiling Tiles
45 - - - - - - <LOD No Asbestos Detected
- - - -
STRUCTURE Concrete 3 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Plaster 18 20.00 0.00 0.00 0.00 20.00 square feet
- Presumed No Yes C 6
WALL Concrete Block 4 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 1: 69219-1 Quantity/ConditionTotal
Location Details: Corridor, N-S outside room 212 (No access above ceiling)
DUCTWORK Uninsulated 2 - - - - - - - - - - - -
PIPING SYSTEMS Aircell On Straight Run Pipe 11 200.00 0.00 0.00 0.00 200.00 linear feet 75 Chrysotile Yes No D 6
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles
35 - - - - - - <LOD No Asbestos Detected
- - - -
STRUCTURE Concrete 3 - - - - - - - - - - - -
PIPING SYSTEMS Cellulose & Tar Paper On Straight Run Pipe 46 - - - - - - <LOD No Asbestos Detected
- - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
PIPING SYSTEMS Parging Cement On Fittings 7 10 2 0 0 12 each 75 Chrysotile Yes No D 6
PIPING SYSTEMS Cellulose On Straight Run Pipe 8 - - - - - - <LOD No Asbestos Detected
- - - -
Comments: Ceiling space was not fully accessible at the time of assessment due to obstructions by mechanical or structural elements or limited points-of-entry. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to ceiling space, suspect that ACMs may be present.
Location: Floor 1: 69219 Quantity/ConditionTotal
Location Details: Corridor, E-W outside Stair C (Limited view above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
44 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 10Golder Associates
Refer to Attachment for Definitions and Abbreviations
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6
WALL Drywall And Joint Compound 33 50.00 0.00 0.00 0.00 50.00 square feet
- Presumed No Yes A 6
WALL Concrete Block 4 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 839.00 0.00 0.00 0.00 839.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69220 Quantity/Condition Total Location Details: Classroom, 220 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
OTHER Window Sealers 12 4 0 0 0 4 each - Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69219-1 Quantity/ConditionTotal
Location Details: Corridor, N-S outside room 212 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
45 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 11Golder Associates
Refer to Attachment for Definitions and Abbreviations
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 295.00 0.00 0.00 0.00 295.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 5 0 0 0 5 each 75 Chrysotile Yes Yes A 6
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 1: 69221 Quantity/ConditionTotal
Location Details: Office / Admin. Area, 221 (No access above ceiling)
CEILING Plaster 26 100.00 0.00 0.00 0.00 100.00 square feet
- Presumed No Yes A 6
CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles
35 - - - - - - <LOD No Asbestos Detected
- - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Plaster 18 8.00 0.00 0.00 0.00 8.00 square feet
- Presumed No Yes C 6
WALL Concrete Block 4 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69220-1 Quantity/Condition Total Location Details: Stairwell, Stair B (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
46 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 12Golder Associates
Refer to Attachment for Definitions and Abbreviations
WALL Concrete Block 4 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 1108.00 0.00 0.00 0.00 1108.00 square feet
- Presumed No Yes A 6
CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles
35 - - - - - - <LOD No Asbestos Detected
- - - -
WALL Transite Asbestos Cement 29 105.00 0.00 0.00 0.00 105.00 square feet
- Presumed No No E 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69222 Quantity/Condition Total Location Details: Classroom, 222 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes C 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69221 Quantity/ConditionTotal
Location Details: Office / Admin. Area, 221 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
47 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 13Golder Associates
Refer to Attachment for Definitions and Abbreviations
FLOOR Vinyl Sheet Flooring 30 102.00 0.00 0.00 0.00 102.00 square feet
- Presumed Yes Yes A 6
WALL Wood 14 - - - - - - - - - - - -
Location: Floor 1: 69225 Quantity/Condition Total Location Details: Kitchen, 229 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Aircell On Straight Run Pipe 11 10.00 0.00 0.00 0.00 10.00 linear feet 75 Chrysotile Yes No D 6
PIPING SYSTEMS Parging Cement On Fittings 7 28 0 2 3 33 each 75 Chrysotile Yes No D 2
OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
WALL Transite Asbestos Cement 29 105.00 0.00 0.00 0.00 105.00 square feet
- Presumed No No E 6
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
WALL Plaster 18 66.00 0.00 0.00 0.00 66.00 square feet
- Presumed No Yes C 6
FLOOR 9" x 9" Vinyl Floor Tile 21 844.00 0.00 1.00 0.00 845.00 square feet
- Presumed No Yes A 3
FLOOR Carpet 41 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
STRUCTURE Wood 14 - - - - - - - - - - - -
STRUCTURE Plaster Column Enclosure 42 36.00 0.00 0.00 0.00 36.00 square feet
- Presumed No Yes A 6
CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles
35 - - - - - - <LOD No Asbestos Detected
- - - -
DUCTWORK Uninsulated 2 - - - - - - - - - - - -
PIPING SYSTEMS Other Suspect Piping 10 50.00 0.00 0.00 0.00 50.00 linear feet - Presumed Yes No D 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69223 Quantity/Condition Total Location Details: Classroom, 223 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
48 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 14Golder Associates
Refer to Attachment for Definitions and Abbreviations
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 15 0 0 0 15 each - Presumed Yes Yes A 6
PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -
WALL Brick 22 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
FLOOR Wood 14 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69226 Quantity/Condition Total Location Details: Gym, Auditorium/228 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
OTHER Vinyl Countertop 32 50.00 0.00 0.00 0.00 50.00 square feet
- Presumed Yes Yes A 6
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69225 Quantity/Condition Total Location Details: Kitchen, 229 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
49 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 15Golder Associates
Refer to Attachment for Definitions and Abbreviations
STRUCTURE Concrete 3 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 1: 69228 Quantity/Condition Total Location Details: Stairwell, Stair C (No access above ceiling)
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
CEILING Transite Asbestos Cement 43 40.00 0.00 0.00 0.00 40.00 square feet
- Presumed No Yes C 6
STRUCTURE Not Found 1 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Transite Asbestos Cement 29 20.00 0.00 0.00 0.00 20.00 square feet
- Presumed No Yes C 6
WALL Concrete Block 4 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69227 Quantity/Condition Total Location Details: Stairwell, Exit 225 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
50 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 16Golder Associates
Refer to Attachment for Definitions and Abbreviations
FLOOR Ceramic 25 - - - - - - - - - - - -
Location: Floor 1: 69230 Quantity/Condition Total Location Details: Washroom, 222C (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Drywall And Joint Compound 34 12.00 0.00 0.00 0.00 12.00 square feet
- Presumed No Yes C 6
STRUCTURE Metal 23 - - - - - - - - - - - -
FLOOR Ceramic 25 - - - - - - - - - - - -
WALL Plaster 18 24.00 0.00 0.00 0.00 24.00 square feet
- Presumed No Yes A 6
WALL Ceramic 25 - - - - - - - - - - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 8 0 1 1 10 each 75 Chrysotile Yes No D 2
DUCTWORK Uninsulated 2 - - - - - - - - - - - -
PIPING SYSTEMS Other Suspect Piping 10 10.00 0.00 0.00 0.00 10.00 linear feet - Presumed Yes No D 6
Comments: Ceiling space was not fully accessible at the time of assessment due to obstructions by mechanical or structural elements or limited points-of-entry. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69229 Quantity/ConditionTotal
Location Details: Washroom, adjoining room 223 (Limited view above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access beneath stairs due to storage.
Location: Floor 1: 69228 Quantity/Condition Total Location Details: Stairwell, Stair C (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
51 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 17Golder Associates
Refer to Attachment for Definitions and Abbreviations
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
OTHER Window Sealers 12 4 0 0 0 4 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles
35 - - - - - - <LOD No Asbestos Detected
- - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 1: 69231 Quantity/Condition Total Location Details: Vestibule, 222A (No access above ceiling)
CEILING Drywall And Joint Compound 34 10.00 0.00 0.00 0.00 10.00 square feet
- Presumed No Yes C 6
STRUCTURE Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
WALL Plaster 18 24.00 0.00 0.00 0.00 24.00 square feet
- Presumed No Yes A 6
WALL Ceramic 25 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69230 Quantity/Condition Total Location Details: Washroom, 222C (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
52 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 18Golder Associates
Refer to Attachment for Definitions and Abbreviations
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 767.00 0.00 0.00 0.00 767.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Cellulose On Straight Run Pipe 8 - - - - - - <LOD No Asbestos Detected
- - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 1: 69233 Quantity/Condition Total Location Details: Main Office, Office (No access above ceiling)
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
WALL Transite Asbestos Cement 29 50.00 0.00 0.00 0.00 50.00 square feet
- Presumed No Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69232 Quantity/ConditionTotal
Location Details: Corridor, N-S between exit 101 and room 209 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
53 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 19Golder Associates
Refer to Attachment for Definitions and Abbreviations
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Drywall And Joint Compound 34 104.00 0.00 0.00 0.00 104.00 square feet
- Presumed No Yes C 6
WALL Brick 22 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 104.00 0.00 0.00 0.00 104.00 square feet
- Presumed No Yes A 6
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 1: 69235 Quantity/Condition Total Location Details: Storage Room, 228A (No access above ceiling)
STRUCTURE Concrete 3 - - - - - - - - - - - -
DUCTWORK Uninsulated 2 - - - - - - - - - - - -
CEILING Not Found 1 - - - - - - - - - - - -
FLOOR Concrete 3 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
PIPING SYSTEMS Bell & Spigot Joints 13 11 0 0 0 11 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 1 0 0 0 1 each - Presumed Yes Yes A 6
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 15 0 0 0 15 each 75 Chrysotile Yes Yes A 6
Location: Floor 1: 69234 Quantity/Condition Total Location Details: Storage Room, PE Equipment/227 (Open)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to wall hatch; painted shut.
Location: Floor 1: 69233 Quantity/Condition Total Location Details: Main Office, Office (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
54 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 20Golder Associates
Refer to Attachment for Definitions and Abbreviations
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
WALL Plaster 18 24.00 0.00 0.00 0.00 24.00 square feet
- Presumed No Yes A 6
WALL Concrete Block 4 - - - - - - - - - - - -
WALL Ceramic 25 - - - - - - - - - - - -
FLOOR Ceramic 25 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING Drywall And Joint Compound 34 10.00 0.00 0.00 0.00 10.00 square feet
- Presumed No Yes C 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69236 Quantity/ConditionTotal
Location Details: Washroom, adjoining room 223 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. Limited access due to storage.
Location: Floor 1: 69235 Quantity/Condition Total Location Details: Storage Room, 228A (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
55 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 21Golder Associates
Refer to Attachment for Definitions and Abbreviations
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
WALL Transite Asbestos Cement 29 30.00 0.00 0.00 0.00 30.00 square feet
- Presumed No Yes A 6
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Brick 22 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 1: 69434 Quantity/Condition Total Location Details: Vestibule, 101 (No access above ceiling)
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Drywall And Joint Compound 34 10.00 0.00 0.00 0.00 10.00 square feet
- Presumed No Yes C 6
STRUCTURE Metal 23 - - - - - - - - - - - -
FLOOR Ceramic 25 - - - - - - - - - - - -
WALL Plaster 18 24.00 0.00 0.00 0.00 24.00 square feet
- Presumed No Yes A 6
WALL Ceramic 25 - - - - - - - - - - - -
DUCTWORK Uninsulated 2 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 1 0 0 1 2 each 75 Chrysotile Yes No D 2
Comments: Ceiling space was not fully accessible at the time of assessment due to obstructions by mechanical or structural elements or limited points-of-entry. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to ceiling space, suspect that ACMs may be present.
Location: Floor 1: 69237 Quantity/Condition Total Location Details: Washroom, 222B (Limited view above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
56 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 22Golder Associates
Refer to Attachment for Definitions and Abbreviations
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 119.00 0.00 2.00 0.00 121.00 square feet
- Presumed No Yes A 3
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 1: 69436 Quantity/ConditionTotal
Location Details: Office / Admin. Area, 232 (No access above ceiling)
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 111.00 0.00 0.00 0.00 111.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69435 Quantity/ConditionTotal
Location Details: Office / Admin. Area, 105 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69434 Quantity/Condition Total Location Details: Vestibule, 101 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
57 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 23Golder Associates
Refer to Attachment for Definitions and Abbreviations
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 1 0 0 0 1 each - Presumed Yes Yes A 6
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 42.00 0.00 0.00 0.00 42.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69437 Quantity/ConditionTotal
Location Details: Storage Room, adjoining room 232 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69436 Quantity/ConditionTotal
Location Details: Office / Admin. Area, 232 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
58 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 24Golder Associates
Refer to Attachment for Definitions and Abbreviations
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 40.00 0.00 1.00 0.00 41.00 square feet
- Presumed No Yes A 3
PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
Location: Floor 1: 69439 Quantity/ConditionTotal
Location Details: Vestibule, between rooms 231 and 232 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 139.00 0.00 0.00 0.00 139.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69438 Quantity/ConditionTotal
Location Details: Office / Admin. Area, 231 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
59 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 25Golder Associates
Refer to Attachment for Definitions and Abbreviations
FLOOR Terrazzo 19 - - - - - - - - - - - -
Location: Floor 1: 69440-1 Quantity/ConditionTotal
Location Details: Stairwell, west of corridor 203 (Limited view above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
DUCTWORK Not Found 1 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 804.00 0.00 0.00 0.00 804.00 square feet
- Presumed No Yes A 6
WALL Ceramic 25 - - - - - - - - - - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles
24 - - - - - - <LOD No Asbestos Detected
- - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 4 0 0 0 4 each 75 Chrysotile Yes Yes C 6
OTHER Horizontal Plaster Bulkhead 27 140.00 0.00 0.00 0.00 140.00 square feet
- Presumed No Yes C 6
WALL Plaster 18 1216.00 0.00 0.00 0.00 1216.00 square feet
- Presumed No Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69440 Quantity/Condition Total Location Details: Classroom, 208 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69439 Quantity/ConditionTotal
Location Details: Vestibule, between rooms 231 and 232 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
60 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 26Golder Associates
Refer to Attachment for Definitions and Abbreviations
CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles
24 - - - - - - <LOD No Asbestos Detected
- - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
WALL Ceramic 25 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 788.00 0.00 0.00 0.00 788.00 square feet
- Presumed No Yes A 6
WALL Plaster 18 1204.00 0.00 0.00 0.00 1204.00 square feet
- Presumed No Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 17 0 0 0 17 each 75 Chrysotile Yes Yes A 6
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 1: 69441 Quantity/Condition Total Location Details: Classroom, 204 (No access above ceiling)
STRUCTURE Concrete 3 - - - - - - - - - - - -
CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles
24 - - - - - - <LOD No Asbestos Detected
- - - -
WALL Plaster 18 200.00 0.00 0.00 0.00 200.00 square feet
- Presumed No Yes A 6
WALL Brick 22 - - - - - - - - - - - -
WALL Metal 23 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 15 0 0 0 15 each 75 Chrysotile Yes Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
Comments: Ceiling space was not fully accessible at the time of assessment due to obstructions by mechanical or structural elements or limited points-of-entry. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to ceiling space, suspect that ACMs may be present.
Location: Floor 1: 69440-1 Quantity/ConditionTotal
Location Details: Stairwell, west of corridor 203 (Limited view above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
61 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 27Golder Associates
Refer to Attachment for Definitions and Abbreviations
PIPING SYSTEMS Parging Cement On Fittings 7 10 0 0 0 10 each 75 Chrysotile Yes Yes A 6
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
PIPING SYSTEMS Bell & Spigot Joints 13 4 0 0 0 4 each - Presumed Yes Yes A 6
FLOOR 12" x 12" Vinyl Floor Tile 17 187.00 0.00 0.00 0.00 187.00 square feet
- Presumed No Yes A 6
CEILING New Ceiling Tile 16 - - - - - - - - - - - -
WALL Ceramic 25 - - - - - - - - - - - -
WALL Plaster 18 585.00 0.00 0.00 0.00 585.00 square feet
- Presumed No Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Other Suspect Piping 10 5.00 0.00 0.00 0.00 5.00 linear feet - Presumed Yes No D 6
CEILING Plaster 26 187.00 0.00 0.00 0.00 187.00 square feet
- Presumed No No D 6
STRUCTURE Wood 14 - - - - - - - - - - - -
Location: Floor 1: 69442 Quantity/ConditionTotal
Location Details: Office / Admin. Area, adjacent to room 208 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Horizontal Plaster Bulkhead 27 140.00 0.00 0.00 0.00 140.00 square feet
- Presumed No Yes C 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69441 Quantity/Condition Total Location Details: Classroom, 204 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
62 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 28Golder Associates
Refer to Attachment for Definitions and Abbreviations
WALL Plaster 18 1192.00 0.00 0.00 0.00 1192.00 square feet
- Presumed No Yes A 6
FLOOR 12" x 12" Vinyl Floor Tile 17 770.00 0.00 0.00 0.00 770.00 square feet
- Presumed No Yes A 6
Location: Floor 1: 69443 Quantity/Condition Total Location Details: Classroom, 206 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles
24 - - - - - - <LOD No Asbestos Detected
- - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
WALL Brick 22 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Plaster 18 430.00 0.00 0.00 0.00 430.00 square feet
- Presumed No Yes A 6
PIPING SYSTEMS Parging Cement On Fittings 7 4 0 0 0 4 each 75 Chrysotile Yes Yes C 6
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69442-1 Quantity/Condition Total Location Details: Corridor, Corridor 203 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Horizontal Plaster Bulkhead 27 60.00 0.00 0.00 0.00 60.00 square feet
- Presumed No Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69442 Quantity/ConditionTotal
Location Details: Office / Admin. Area, adjacent to room 208 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
63 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 29Golder Associates
Refer to Attachment for Definitions and Abbreviations
CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles
24 - - - - - - <LOD No Asbestos Detected
- - - -
STRUCTURE Concrete 3 - - - - - - - - - - - -
WALL Brick 22 - - - - - - - - - - - -
WALL Metal 23 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 18 0 0 0 18 each 75 Chrysotile Yes Yes A 6
WALL Plaster 18 200.00 0.00 0.00 0.00 200.00 square feet
- Presumed No Yes A 6
FLOOR Terrazzo 19 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 1: 69443-1 Quantity/Condition Total Location Details: Stairwell, Stair A (Limited view above ceiling)
PIPING SYSTEMS Other Suspect Piping 10 5.00 0.00 0.00 0.00 5.00 linear feet - Presumed Yes Yes C 6
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles
24 - - - - - - <LOD No Asbestos Detected
- - - -
WALL Ceramic 25 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6
OTHER Horizontal Plaster Bulkhead 27 140.00 0.00 0.00 0.00 140.00 square feet
- Presumed No Yes C 6
PIPING SYSTEMS Parging Cement On Fittings 7 4 0 0 0 4 each 75 Chrysotile Yes Yes C 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69443 Quantity/Condition Total Location Details: Classroom, 206 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
64 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 30Golder Associates
Refer to Attachment for Definitions and Abbreviations
OTHER Horizontal Plaster Bulkhead 27 140.00 0.00 0.00 0.00 140.00 square feet
- Presumed No Yes C 6
CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles
24 - - - - - - <LOD No Asbestos Detected
- - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 773.00 0.00 0.00 0.00 773.00 square feet
- Presumed No Yes A 6
WALL Plaster 18 1192.00 0.00 0.00 0.00 1192.00 square feet
- Presumed No Yes A 6
WALL Ceramic 25 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 4 0 0 0 4 each 75 Chrysotile Yes Yes C 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69444 Quantity/Condition Total Location Details: Classroom, 205 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was not fully accessible at the time of assessment due to obstructions by mechanical or structural elements or limited points-of-entry. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to ceiling space, suspect that ACMs may be present.
Location: Floor 1: 69443-1 Quantity/Condition Total Location Details: Stairwell, Stair A (Limited view above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
65 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 31Golder Associates
Refer to Attachment for Definitions and Abbreviations
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 198.00 0.00 0.00 0.00 198.00 square feet
- Presumed No Yes A 6
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 1: 69446 Quantity/Condition Total Location Details: Kitchen, 230 (No access above ceiling)
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
FLOOR Vinyl Sheet Flooring 30 429.00 0.00 0.00 0.00 429.00 square feet
- Presumed Yes Yes A 6
WALL Wood 14 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69445 Quantity/ConditionTotal
Location Details: Office / Admin. Area, 209 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
66 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 32Golder Associates
Refer to Attachment for Definitions and Abbreviations
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 736.00 0.00 0.00 0.00 736.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
Location: Floor 1: 69448 Quantity/Condition Total Location Details: Classroom, 212 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 744.00 0.00 0.00 0.00 744.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69447 Quantity/Condition Total Location Details: Classroom, 211 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Window Sealers 12 5 0 0 0 5 each - Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69446 Quantity/Condition Total Location Details: Kitchen, 230 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
67 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 33Golder Associates
Refer to Attachment for Definitions and Abbreviations
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Ceramic 25 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING Drywall And Joint Compound 34 239.00 0.00 0.00 0.00 239.00 square feet
- Presumed No Yes C 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to ceiling hatch; hatch stuck shut.
Location: Floor 1: 69449 Quantity/Condition Total Location Details: Washroom - Girls, 213A (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
OTHER Vinyl Countertop 32 25.00 0.00 0.00 0.00 25.00 square feet
- Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69448 Quantity/Condition Total Location Details: Classroom, 212 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
68 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 34Golder Associates
Refer to Attachment for Definitions and Abbreviations
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING Drywall And Joint Compound 34 230.00 0.00 0.00 0.00 230.00 square feet
- Presumed No Yes C 6
OTHER Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Ceramic 25 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 1: 69450 Quantity/Condition Total Location Details: Washroom - Boys, 216A (No access above ceiling)
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
CEILING Wood 14 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69449-1 Quantity/Condition Total Location Details: Vestibule, 213 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
69 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 35Golder Associates
Refer to Attachment for Definitions and Abbreviations
CEILING Drywall And Joint Compound 34 30.00 0.00 0.00 0.00 30.00 square feet
- Presumed No Yes C 6
STRUCTURE Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Wood 14 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
WALL Ceramic 25 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 1: 69451 Quantity/Condition Total Location Details: Washroom, Staff/215 (No access above ceiling)
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Wood 14 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 1: 69450-1 Quantity/Condition Total Location Details: Vestibule, 216 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
70 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 36Golder Associates
Refer to Attachment for Definitions and Abbreviations
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING Wood 14 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
FLOOR Concrete 3 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 1: 69452 Quantity/Condition Total Location Details: Caretakers Room, 214 (No access above ceiling)
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Metal 23 - - - - - - - - - - - -
CEILING Not Found 1 - - - - - - - - - - - -
FLOOR Dirt, Sand Or Gravel 44 - - - - - - - - - - - -
WALL Concrete 3 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
PIPING SYSTEMS Other Suspect Piping 10 100.00 0.00 0.00 0.00 100.00 linear feet - Presumed Yes Yes B 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Bell & Spigot Joints 13 20 0 0 0 20 each - Presumed Yes Yes B 6
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
Comments: No access to tunnel below.
Location: Floor 1: 69451-1 Quantity/ConditionTotal
Location Details: Maintenance Room, pipe chase adjoining room 215 (Open)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
71 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 37Golder Associates
Refer to Attachment for Definitions and Abbreviations
WALL Ceramic 25 - - - - - - - - - - - -
CEILING Drywall And Joint Compound 34 39.00 0.00 0.00 0.00 39.00 square feet
- Presumed No Yes C 6
FLOOR Ceramic 25 - - - - - - - - - - - -
WALL Plaster 18 180.00 0.00 0.00 0.00 180.00 square feet
- Presumed No Yes A 6
STRUCTURE Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69239 Quantity/Condition Total Location Details: Washroom, Staff/324 (No access above ceiling)
WALL Brick 22 - - - - - - - - - - - -
CEILING Drywall And Joint Compound 34 67.00 0.00 0.00 0.00 67.00 square feet
- Presumed No Yes C 6
WALL Plaster 18 250.00 0.00 0.00 0.00 250.00 square feet
- Presumed No Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 67.00 0.00 0.00 0.00 67.00 square feet
- Presumed No Yes A 6
STRUCTURE Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69238 Quantity/ConditionTotal
Location Details: Storage Room, Stockroom/325 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
72 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 38Golder Associates
Refer to Attachment for Definitions and Abbreviations
FLOOR 12" x 12" Vinyl Floor Tile 17 475.00 0.00 0.00 0.00 475.00 square feet
- Presumed No Yes A 6
WALL Plaster 18 610.00 0.00 0.00 0.00 610.00 square feet
- Presumed No Yes A 6
WALL Marble 31 - - - - - - - - - - - -
Location: Floor 2: 69241 Quantity/Condition Total Location Details: Staff Room, Staff/323 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
STRUCTURE Not Found 1 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 85.00 0.00 0.00 0.00 85.00 square feet
- Presumed No Yes A 6
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
CEILING Drywall And Joint Compound 34 85.00 0.00 0.00 0.00 85.00 square feet
- Presumed No Yes C 6
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
WALL Plaster 18 250.00 0.00 0.00 0.00 250.00 square feet
- Presumed No Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69240 Quantity/Condition Total Location Details: Kitchen, 323A (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69239 Quantity/Condition Total Location Details: Washroom, Staff/324 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
73 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 39Golder Associates
Refer to Attachment for Definitions and Abbreviations
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles
35 - - - - - - <LOD No Asbestos Detected
- - - -
OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 450.00 0.00 0.00 0.00 450.00 square feet
- Presumed No Yes A 6
WALL Plaster 18 300.00 0.00 0.00 0.00 300.00 square feet
- Presumed No Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69241-1 Quantity/ConditionTotal
Location Details: Corridor, outside room 324 (No access above ceiling)
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles
35 - - - - - - <LOD No Asbestos Detected
- - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Vertical Plaster Bulkhead 36 20.00 0.00 0.00 0.00 20.00 square feet
- Presumed No Yes A 6
OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69241 Quantity/Condition Total Location Details: Staff Room, Staff/323 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
74 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 40Golder Associates
Refer to Attachment for Definitions and Abbreviations
WALL Marble 31 - - - - - - - - - - - -
CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles
24 - - - - - - <LOD No Asbestos Detected
- - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Plaster 18 400.00 0.00 0.00 0.00 400.00 square feet
- Presumed No Yes A 6
WALL Metal 23 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69242-1 Quantity/ConditionTotal
Location Details: Stairwell, west of corridor 301 (No access above ceiling)
WALL Marble 31 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
WALL Brick 22 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 115.00 0.00 0.00 0.00 115.00 square feet
- Presumed No Yes A 6
FLOOR Vinyl Sheet Flooring 30 689.00 0.00 0.00 0.00 689.00 square feet
- Presumed Yes Yes A 6
WALL Wood 14 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6
OTHER Vinyl Countertop 32 10.00 0.00 0.00 0.00 10.00 square feet
- Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69242 Quantity/Condition Total Location Details: Classroom, 305 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
75 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 41Golder Associates
Refer to Attachment for Definitions and Abbreviations
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
FLOOR Vinyl Sheet Flooring 30 50.00 0.00 0.00 0.00 50.00 square feet
- Presumed Yes Yes A 6
FLOOR 12" x 12" Vinyl Floor Tile 17 738.00 0.00 0.00 0.00 738.00 square feet
- Presumed No Yes A 6
WALL Concrete Block 4 - - - - - - - - - - - -
WALL Drywall And Joint Compound 33 35.00 0.00 0.00 0.00 35.00 square feet
- Presumed No Yes A 6
WALL Marble 31 - - - - - - - - - - - -
Location: Floor 2: 69243 Quantity/Condition Total Location Details: Classroom, 326 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes C 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69242-1 Quantity/ConditionTotal
Location Details: Stairwell, west of corridor 301 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
76 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 42Golder Associates
Refer to Attachment for Definitions and Abbreviations
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
OTHER Vinyl Countertop 32 20.00 0.00 0.00 0.00 20.00 square feet
- Presumed Yes Yes A 6
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
WALL Brick 22 - - - - - - - - - - - -
WALL Drywall And Joint Compound 33 60.00 0.00 0.00 0.00 60.00 square feet
- Presumed No Yes A 6
FLOOR 12" x 12" Vinyl Floor Tile 17 153.00 0.00 0.00 0.00 153.00 square feet
- Presumed No Yes A 6
WALL Plaster 18 105.00 0.00 0.00 0.00 105.00 square feet
- Presumed No Yes A 6
WALL Concrete Block 4 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69244 Quantity/ConditionTotal
Location Details: Teachers Workroom, Tutorial/304 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Vinyl Countertop 32 15.00 0.00 0.00 0.00 15.00 square feet
- Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to fan enclosure EF-05.
Location: Floor 2: 69243 Quantity/Condition Total Location Details: Classroom, 326 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
77 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 43Golder Associates
Refer to Attachment for Definitions and Abbreviations
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
WALL Drywall And Joint Compound 33 136.00 0.00 0.00 0.00 136.00 square feet
- Presumed No Yes A 6
WALL Concrete Block 4 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
FLOOR Vinyl Sheet Flooring 30 22.00 0.00 0.00 0.00 22.00 square feet
- Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69245 Quantity/Condition Total Location Details: Washroom, 304A (No access above ceiling)
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Plaster 18 600.00 0.00 0.00 0.00 600.00 square feet
- Presumed No Yes A 6
WALL Ceramic 25 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69244-1 Quantity/Condition Total Location Details: Corridor, Corridor 301 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
78 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 44Golder Associates
Refer to Attachment for Definitions and Abbreviations
WALL Marble 31 - - - - - - - - - - - -
WALL Drywall And Joint Compound 33 35.00 0.00 0.00 0.00 35.00 square feet
- Presumed No Yes A 6
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 672.00 0.00 0.00 0.00 672.00 square feet
- Presumed No Yes A 6
FLOOR Vinyl Sheet Flooring 30 50.00 0.00 0.00 0.00 50.00 square feet
- Presumed Yes Yes A 6
WALL Wood 14 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69247 Quantity/Condition Total Location Details: Classroom, 327 (No access above ceiling)
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 10.00 0.00 0.00 0.00 10.00 square feet
- Presumed No Yes B 6
WALL Brick 22 - - - - - - - - - - - -
WALL Drywall And Joint Compound 33 60.00 0.00 0.00 0.00 60.00 square feet
- Presumed No Yes B 6
STRUCTURE Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Bell & Spigot Joints 13 5 0 0 0 5 each - Presumed Yes Yes B 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69246 Quantity/Condition Total Location Details: Caretakers Room, 303 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
79 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 45Golder Associates
Refer to Attachment for Definitions and Abbreviations
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
FLOOR Vinyl Sheet Flooring 30 655.00 0.00 0.00 0.00 655.00 square feet
- Presumed Yes Yes A 6
FLOOR 12" x 12" Vinyl Floor Tile 17 115.00 0.00 0.00 0.00 115.00 square feet
- Presumed No Yes A 6
WALL Marble 31 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
WALL Drywall And Joint Compound 33 35.00 0.00 0.00 0.00 35.00 square feet
- Presumed No Yes A 6
Location: Floor 2: 69248 Quantity/Condition Total Location Details: Classroom, 302 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Window Sealers 12 6 0 0 0 6 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
OTHER Vinyl Countertop 32 15.00 0.00 0.00 0.00 15.00 square feet
- Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to fan enclosure EF-04.
Location: Floor 2: 69247 Quantity/Condition Total Location Details: Classroom, 327 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
80 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 46Golder Associates
Refer to Attachment for Definitions and Abbreviations
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING Wood 14 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
Location: Floor 2: 69249 Quantity/Condition Total Location Details: Caretakers Room, 308 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
CEILING 1x1 asymmetric medium and large holes Glue On Ceiling Tiles
24 - - - - - - <LOD No Asbestos Detected
- - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
WALL Metal 23 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Plaster 18 400.00 0.00 0.00 0.00 400.00 square feet
- Presumed No Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69248-1 Quantity/Condition Total Location Details: Stairwell, Stair A (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Vinyl Countertop 32 15.00 0.00 0.00 0.00 15.00 square feet
- Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access to fan enclosure EF-03.
Location: Floor 2: 69248 Quantity/Condition Total Location Details: Classroom, 302 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
81 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 47Golder Associates
Refer to Attachment for Definitions and Abbreviations
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Wood 14 - - - - - - - - - - - -
WALL Ceramic 25 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69251 Quantity/Condition Total Location Details: Washroom - Boys, 310 (No access above ceiling)
WALL Ceramic 25 - - - - - - - - - - - -
CEILING Wood 14 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 1 0 0 0 1 each - Presumed Yes Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69250 Quantity/Condition Total Location Details: Washroom - Girls, 307 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69249 Quantity/Condition Total Location Details: Caretakers Room, 308 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
82 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 48Golder Associates
Refer to Attachment for Definitions and Abbreviations
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6
OTHER Vinyl Countertop 32 25.00 0.00 0.00 0.00 25.00 square feet
- Presumed Yes Yes A 6
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 744.00 0.00 0.00 0.00 744.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69252 Quantity/Condition Total Location Details: Classroom, 311 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 1 0 0 0 1 each - Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69251 Quantity/Condition Total Location Details: Washroom - Boys, 310 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
83 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 49Golder Associates
Refer to Attachment for Definitions and Abbreviations
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles
35 - - - - - - <LOD No Asbestos Detected
- - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Plaster 18 200.00 0.00 0.00 0.00 200.00 square feet
- Presumed No Yes A 6
WALL Brick 22 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69253-1 Quantity/ConditionTotal
Location Details: Corridor, E-W outside Stair C (No access above ceiling)
CEILING Plaster 26 27.00 0.00 0.00 0.00 27.00 square feet
- Presumed No Yes A 6
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Plaster 18 18.00 0.00 0.00 0.00 18.00 square feet
- Presumed No Yes A 6
WALL Concrete Block 4 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 10 0 0 0 10 each - Presumed Yes Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69253 Quantity/ConditionTotal
Location Details: Corridor, N-S outside room 312 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
84 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 50Golder Associates
Refer to Attachment for Definitions and Abbreviations
FLOOR 9" x 9" Vinyl Floor Tile 21 20.00 0.00 1.00 0.00 21.00 square feet
- Presumed No Yes A 3
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69255 Quantity/Condition Total Location Details: Washroom, 314A (No access above ceiling)
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 736.00 0.00 0.00 0.00 736.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
OTHER Vinyl Countertop 32 25.00 0.00 0.00 0.00 25.00 square feet
- Presumed Yes Yes A 6
WALL Wood 14 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69254 Quantity/Condition Total Location Details: Classroom, 312 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69253-1 Quantity/ConditionTotal
Location Details: Corridor, E-W outside Stair C (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
85 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 51Golder Associates
Refer to Attachment for Definitions and Abbreviations
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles
35 - - - - - - <LOD No Asbestos Detected
- - - -
WALL Plaster 18 360.00 0.00 0.00 0.00 360.00 square feet
- Presumed No Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 182.00 0.00 0.00 0.00 182.00 square feet
- Presumed No Yes A 6
FLOOR 12" x 12" Vinyl Floor Tile 17 4.00 0.00 0.00 0.00 4.00 square feet
- Presumed No Yes A 6
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69256 Quantity/ConditionTotal
Location Details: Teachers Workroom, 314 (No access above ceiling)
DUCTWORK Not Found 1 - - - - - - - - - - - -
WALL Plaster 18 125.00 0.00 0.00 0.00 125.00 square feet
- Presumed No Yes A 6
CEILING Drywall And Joint Compound 34 21.00 0.00 0.00 0.00 21.00 square feet
- Presumed No Yes C 6
STRUCTURE Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69255 Quantity/Condition Total Location Details: Washroom, 314A (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
86 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 52Golder Associates
Refer to Attachment for Definitions and Abbreviations
FLOOR 12" x 12" Vinyl Floor Tile 17 45.00 0.00 0.00 0.00 45.00 square feet
- Presumed No Yes A 6
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69258 Quantity/Condition Total Location Details: Photocopy Room, 314B (No access above ceiling)
CEILING Drywall And Joint Compound 34 102.00 0.00 0.00 0.00 102.00 square feet
- Presumed No Yes C 6
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 102.00 0.00 0.00 0.00 102.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
WALL Plaster 18 120.00 0.00 0.00 0.00 120.00 square feet
- Presumed No Yes A 6
STRUCTURE Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Horizontal Drywall Bulkhead 38 20.00 0.00 0.00 0.00 20.00 square feet
- Presumed No Yes C 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69257 Quantity/Condition Total Location Details: Hub Room, 315 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos. No access beneath sink.
Location: Floor 2: 69256 Quantity/ConditionTotal
Location Details: Teachers Workroom, 314 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
87 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 53Golder Associates
Refer to Attachment for Definitions and Abbreviations
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Drywall And Joint Compound 34 213.00 0.00 0.00 0.00 213.00 square feet
- Presumed No Yes C 6
WALL Wood 14 - - - - - - - - - - - -
WALL Brick 22 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 213.00 0.00 0.00 0.00 213.00 square feet
- Presumed No Yes A 6
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69259 Quantity/ConditionTotal
Location Details: Office / Admin. Area, 317 (No access above ceiling)
DUCTWORK Not Found 1 - - - - - - - - - - - -
CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles
35 - - - - - - <LOD No Asbestos Detected
- - - -
WALL Plaster 18 200.00 0.00 0.00 0.00 200.00 square feet
- Presumed No Yes A 6
FLOOR 9" x 9" Vinyl Floor Tile 21 64.00 0.00 0.00 0.00 64.00 square feet
- Presumed No Yes A 6
STRUCTURE Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69258 Quantity/Condition Total Location Details: Photocopy Room, 314B (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
88 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 54Golder Associates
Refer to Attachment for Definitions and Abbreviations
FLOOR 12" x 12" Vinyl Floor Tile 17 177.00 0.00 0.00 0.00 177.00 square feet
- Presumed No Yes A 6
WALL Drywall And Joint Compound 33 257.00 0.00 0.00 0.00 257.00 square feet
- Presumed No Yes A 6
Location: Floor 2: 69261 Quantity/ConditionTotal
Location Details: Office / Admin. Area, Staff/318B (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
CEILING Drywall And Joint Compound 34 23.00 0.00 0.00 0.00 23.00 square feet
- Presumed No Yes C 6
WALL Plaster 18 95.00 0.00 0.00 0.00 95.00 square feet
- Presumed No Yes B 6
WALL Concrete Block 4 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 23.00 0.00 0.00 0.00 23.00 square feet
- Presumed No Yes B 6
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69260 Quantity/Condition Total Location Details: Caretakers Room, 316 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Window Sealers 12 3 0 0 0 3 each - Presumed Yes Yes C 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69259 Quantity/ConditionTotal
Location Details: Office / Admin. Area, 317 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
89 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 55Golder Associates
Refer to Attachment for Definitions and Abbreviations
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
CEILING 1x1 random medium and large holes Glue On Ceiling Tiles
39 - - - - - - <LOD No Asbestos Detected
- - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 167.00 0.00 0.00 0.00 167.00 square feet
- Presumed No Yes A 6
WALL Drywall And Joint Compound 33 266.00 0.00 0.00 0.00 266.00 square feet
- Presumed No Yes A 6
WALL Concrete Block 4 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69453 Quantity/ConditionTotal
Location Details: Teachers Workroom, 318A (No access above ceiling)
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING 1x1 random medium and large holes Glue On Ceiling Tiles
39 - - - - - - <LOD No Asbestos Detected
- - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
OTHER Window Sealers 12 4 0 0 0 4 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69261 Quantity/ConditionTotal
Location Details: Office / Admin. Area, Staff/318B (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
90 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 56Golder Associates
Refer to Attachment for Definitions and Abbreviations
WALL Concrete Block 4 - - - - - - - - - - - -
WALL Plaster 18 8.00 0.00 0.00 0.00 8.00 square feet
- Presumed No Yes C 6
FLOOR Terrazzo 19 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69454-1 Quantity/Condition Total Location Details: Stairwell, Stair C (No access above ceiling)
CEILING 1x1 random medium and large holes Glue On Ceiling Tiles
39 - - - - - - <LOD No Asbestos Detected
- - - -
WALL Concrete Block 4 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 1320.00 0.00 0.00 0.00 1320.00 square feet
- Presumed No Yes A 6
WALL Drywall And Joint Compound 33 215.00 0.00 0.00 0.00 215.00 square feet
- Presumed No Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 15 0 0 0 15 each - Presumed Yes Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69454 Quantity/Condition Total Location Details: Library, 318 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Vertical Drywall Bulkhead 40 35.00 0.00 0.00 0.00 35.00 square feet
- Presumed No Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69453 Quantity/ConditionTotal
Location Details: Teachers Workroom, 318A (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
91 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 57Golder Associates
Refer to Attachment for Definitions and Abbreviations
PIPING SYSTEMS Parging Cement On Fittings 7 3 2 0 0 5 each 75 Chrysotile Yes No D 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
FLOOR 12" x 12" Vinyl Floor Tile 17 720.00 0.00 0.00 0.00 720.00 square feet
- Presumed No Yes A 6
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles
35 - - - - - - <LOD No Asbestos Detected
- - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
DUCTWORK Uninsulated 2 - - - - - - - - - - - -
STRUCTURE Wood 14 - - - - - - - - - - - -
Comments: Ceiling space was not fully accessible at the time of assessment due to obstructions by mechanical or structural elements or limited points-of-entry. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69455 Quantity/ConditionTotal
Location Details: Corridor, E-W outside room 318 (Limited view above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles
35 - - - - - - <LOD No Asbestos Detected
- - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
OTHER Window Sealers 12 8 0 0 0 8 each - Presumed Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69454-1 Quantity/Condition Total Location Details: Stairwell, Stair C (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
92 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 58Golder Associates
Refer to Attachment for Definitions and Abbreviations
CEILING Not Found 1 - - - - - - - - - - - -
STRUCTURE Wood 14 - - - - - - - - - - - -
DUCTWORK Parging Cement On Seam, Joints And Pins 48 25.00 0.00 0.00 0.00 25.00 square feet
50 Chrysotile Yes Yes C 6
WALL Concrete 3 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
WALL Perforated Transite Asbestos Cement 47 180.00 0.00 0.00 0.00 180.00 square feet
- Presumed No Yes B 6
MECHANICAL EQUIPMENT
Uninsulated 2 - - - - - - - - - - - -
DUCTWORK Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 25 0 0 0 25 each 75 Chrysotile Yes Yes B 6
FLOOR Concrete 3 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69457 Quantity/Condition Total Location Details: Mechanical Room, 318D (Open)
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING Drywall And Joint Compound 34 80.00 0.00 0.00 0.00 80.00 square feet
- Presumed No Yes C 6
FLOOR 9" x 9" Vinyl Floor Tile 21 79.00 0.00 1.00 0.00 80.00 square feet
- Presumed No Yes A 3
WALL Concrete Block 4 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Fibreglass And Uninsulated 6 - - - - - - - - - - - -
PIPING SYSTEMS Parging Cement On Fittings 7 4 0 0 0 4 each 75 Chrysotile Yes Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69456 Quantity/Condition Total Location Details: Storage Room, 318C (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
93 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 59Golder Associates
Refer to Attachment for Definitions and Abbreviations
FLOOR 9" x 9" Vinyl Floor Tile 21 700.00 0.00 0.00 0.00 700.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
Location: Floor 2: 69459 Quantity/Condition Total Location Details: Classroom, 319 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
WALL Wood 14 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 1597.00 0.00 0.00 0.00 1597.00 square feet
- Presumed No Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
OTHER Vertical Drywall Bulkhead 40 50.00 0.00 0.00 0.00 50.00 square feet
- Presumed No Yes A 6
OTHER Window Sealers 12 18 0 0 0 18 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
CEILING 1x1 random medium and large holes Glue On Ceiling Tiles
39 - - - - - - <LOD No Asbestos Detected
- - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69458 Quantity/Condition Total Location Details: Library, 318 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
OTHER Woven Flexible Duct Connector 37 0.00 0.00 0.00 0.00 0.00 square feet
- Presumed No No N/A
OTHER Window Sealers 12 1 0 0 0 1 each - Presumed Yes Yes C 6
Location: Floor 2: 69457 Quantity/Condition Total Location Details: Mechanical Room, 318D (Open)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
94 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 60Golder Associates
Refer to Attachment for Definitions and Abbreviations
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING Wood 14 - - - - - - - - - - - -
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR 12" x 12" Vinyl Floor Tile 17 56.00 0.00 0.00 0.00 56.00 square feet
- Presumed No Yes A 6
FLOOR 9" x 9" Vinyl Floor Tile 21 84.00 0.00 0.00 0.00 84.00 square feet
- Presumed No Yes A 6
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69460 Quantity/Condition Total Location Details: Storage Room, 320 (No access above ceiling)
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
OTHER Vinyl Countertop 32 25.00 0.00 0.00 0.00 25.00 square feet
- Presumed Yes Yes A 6
OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69459 Quantity/Condition Total Location Details: Classroom, 319 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
95 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 61Golder Associates
Refer to Attachment for Definitions and Abbreviations
DUCTWORK Not Found 1 - - - - - - - - - - - -
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
OTHER Vinyl Countertop 32 25.00 0.00 0.00 0.00 25.00 square feet
- Presumed Yes Yes A 6
OTHER Window Sealers 12 9 0 0 0 9 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 767.00 0.00 0.00 0.00 767.00 square feet
- Presumed No Yes A 6
WALL Wood 14 - - - - - - - - - - - -
WALL Wood 14 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Floor 2: 69462 Quantity/Condition Total Location Details: Classroom, A321 (No access above ceiling)
STRUCTURE Wood 14 - - - - - - - - - - - -
DUCTWORK Uninsulated 2 - - - - - - - - - - - -
CEILING Not Found 1 - - - - - - - - - - - -
FLOOR Concrete 3 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Uninsulated 2 - - - - - - - - - - - -
OTHER Woven Flexible Duct Connector 37 0.00 0.00 0.00 0.00 0.00 square feet
- Presumed No No N/A
PIPING SYSTEMS Bell & Spigot Joints 13 6 0 0 0 6 each - Presumed Yes Yes B 6
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Location: Floor 2: 69461 Quantity/Condition Total Location Details: Mechanical Room, 322 (Open)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
96 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 62Golder Associates
Refer to Attachment for Definitions and Abbreviations
PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
OTHER Vertical Plaster Bulkhead 36 15.00 0.00 0.00 0.00 15.00 square feet
- Presumed No Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
WALL Plaster 18 220.00 0.00 0.00 0.00 220.00 square feet
- Presumed No Yes A 6
FLOOR 9" x 9" Vinyl Floor Tile 21 43.00 0.00 0.00 0.00 43.00 square feet
- Presumed No Yes A 6
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles
35 - - - - - - <LOD No Asbestos Detected
- - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69463 Quantity/Condition Total Location Details: Empty Room, 313 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
STRUCTURE Not Found 1 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
CEILING Cellulose (Wood Fibre) 28 - - - - - - - - - - - -
FLOOR Terrazzo 19 - - - - - - - - - - - -
WALL Concrete Block 4 - - - - - - - - - - - -
OTHER Window Sealers 12 2 0 0 0 2 each - Presumed Yes Yes A 6
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69462-1 Quantity/Condition Total Location Details: Stairwell, Stair C (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
97 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 63Golder Associates
Refer to Attachment for Definitions and Abbreviations
WALL Concrete 3 - - - - - - - - - - - -
CEILING Transite Asbestos Cement 43 360.00 0.00 0.00 0.00 360.00 square feet
- Presumed No Yes C 6
WALL Transite Asbestos Cement 29 700.00 0.00 0.00 0.00 700.00 square feet
- Presumed No Yes C 6
FLOOR Other Non-Suspect 49 - - - - - - - - - - - -
WALL Brick 22 - - - - - - - - - - - -
STRUCTURE Concrete 3 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Bell & Spigot Joints 13 3 0 0 0 3 each - Presumed Yes Yes A 6
FLOOR Concrete 3 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Exterior: 68443-1 Quantity/Condition Total Location Details: Exterior (Open)
STRUCTURE Not Found 1 - - - - - - - - - - - -
CEILING 1x1 large fissures and pinholes Glue On Ceiling Tiles
35 - - - - - - <LOD No Asbestos Detected
- - - -
FLOOR 9" x 9" Vinyl Floor Tile 21 83.00 0.00 0.00 0.00 83.00 square feet
- Presumed No Yes A 6
WALL Plaster 18 200.00 0.00 0.00 0.00 200.00 square feet
- Presumed No Yes A 6
DUCTWORK Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Uninsulated 2 - - - - - - - - - - - -
Comments: Ceiling space was inaccessible at the time of assessment. Asbestos-containing materials (ACM) may exist in the ceiling space. If this space is to be accessed for any reason, such as a roof leak, etc., an inspection should be conducted by a competent person and any suspect ACM should be sampled or presumed to contain asbestos.
Location: Floor 2: 69464 Quantity/ConditionTotal
Location Details: Computer Room, adjoining room 314 (No access above ceiling)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
98 of 99
Date: 11/21/2008
Job Number : 06-1113-212Facility : 3088 - Dublin PS
Client : Toronto District School Board
All Components
Appendix IV - Room-by-Room Details: Summary Report By Location
Page: 64Golder Associates
Refer to Attachment for Definitions and Abbreviations
STRUCTURE Not Found 1 - - - - - - - - - - - -
FLOOR Built Up Membrane Roof 52 22000.00 0.00 0.00 0.00 22000.00 square feet
- Presumed No Yes B 6
WALL Not Found 1 - - - - - - - - - - - -
CEILING Not Found 1 - - - - - - - - - - - -
OTHER Brick/Block/Concrete 5 - - - - - - - - - - - -
DUCTWORK Not Found 1 - - - - - - - - - - - -
PIPING SYSTEMS Not Found 1 - - - - - - - - - - - -
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Location: Roof: 68443 Quantity/Condition Total Location Details: Roof (Open)
MECHANICAL EQUIPMENT
Not Found 1 - - - - - - - - - - - -
OTHER Not Found 1 - - - - - - - - - - - -
Location: Exterior: 68443-1 Quantity/Condition Total Location Details: Exterior (Open)
System Material Description Component Good Fair Poor Debris Quantity Units Asbestos %
Asbestos Type
Friable Visible Accessibility Action Code
Building: 1 (Dublin PS)
99 of 99