101, 2903 35 Avenue Vernon, BC V1T 2S7 T: 250.545.0784 F: 250.545.0730 E: [email protected] Garry J. Tomporowski, Architect AIBC, B.E.S., MArch. Kimberly Fuller, Architect AIBC, BFA, BEDS, MArch The following information supplements and/or supersedes the bid documents issued on October 20 th , 2017, 12:00 PM PDT. This Addendum forms part of the contract documents and is to be read, interpreted, and coordinated with all other parts. The cost of all contained herein is to be included in the contract sum. The following revisions supersede the information contained in the original drawings and specifications issued for the above-named project to the extent referenced and shall become part thereof. Acknowledge receipt of this Addendum by inserting its number and date on the Tender Form. Failure to do so may subject bidder to disqualification. 1. Doors & Door hardware: See Drawing A2.2 attached. Office Doors: D202, 206, 207, 208, 212, 213 changed to lock sets, note on schedule. - ALL FIRE RATED, ENTRY DOOR CLOSURES TO BE LCN4040XP OR EQUIV. - ALL CYLINDRICAL LOCKS TO BE SCHLAGE AL SERIES OR EQUIV. - ALL EXIT DEVICES TO BE 22 SERIES OR EQUIV. - ALL MEDIUM USE, FIRE RATED CLOSURES 1461 OR EQUIV. - ALL THRESHOLDS TO BE DRAFT STEEL OR EQUIV. - ALL WALL STOPS & KICK PLATES TO BE GALLERY HARDWARE OR EQUIV. 2. Windows: Match existing aluminium frame as per specified in drawing A2.2 attached. 3. Ceiling Tile: T-bar Tile - Armstrong Cortega Second Look II - a 24 x 48 with scored line so it appears like a 2 x 2, or equiv. 2 x 2 lighting proposed in electrical drawings to remain. 4. Millwork specifications: See updated Drawing ID-1 and ID-2 attached. 5. Stairwell treads: See updated Drawing ID-1 and ID-2 attached. 6. Washroom 207,208 mechanical clarification: The upper floor washrooms have been plumbed, but currently there are no fixtures, finishes and the walls have been framed only. 7. Where is DHWT-2 relocated from? See as-builts, above in area with currently no floor. 8. Are there asbuilt drawings for electrical and mechanical? See attached. 9. Stack Vents: The 2 existing stack vents shown on second floor drawings - Contractor to breakout cost to keep stack vent as-is with additional fin-walls or move as per original drawings in A2.2. 10. What is the R-value standard for the new roller O/H Doors? Because these O/H doors will be used for frozen fish storage, the typical R2+ value for a roller O/H door should be sufficient. 11. Will bidders be revealed to the general public? No. Attachments: 1. Second Floor Plan & Window/Door Schedule 2.2 - Addendum 2 Revision 1 page 2. Interior Design: Finishes Plan ID-1 - Addendum 2 Revision 1 page 3. Interior Design: Elevations & Sections ID-2 - Addendum 2 Revision 1 page 4. As-builts Structural 9 pages 5. As-builts Mechanical 4 pages 6. As-builts Electrical 7 pages Addendum No.002 FILE: VA1719 # of PAGES: 24 DATE: November 1, 2017 PROJECT: FNHA Office Fit-ups West Kelowna, BC

Upload: others

Post on 14-Jun-2020

30 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

101, 2903 35 Avenue

Vernon, BC V1T 2S7

T: 250.545.0784

F: 250.545.0730

E: [email protected]

Garry J. Tomporowski, Architect AIBC, B.E.S., MArch.

Kimberly Fuller, Architect AIBC, BFA, BEDS, MArch

The following information supplements and/or supersedes the bid documents issued on October 20th, 2017,

12:00 PM PDT.

This Addendum forms part of the contract documents and is to be read, interpreted, and coordinated

with all other parts. The cost of all contained herein is to be included in the contract sum. The following

revisions supersede the information contained in the original drawings and specifications issued for the

above-named project to the extent referenced and shall become part thereof. Acknowledge receipt of

this Addendum by inserting its number and date on the Tender Form. Failure to do so may subject bidder to

disqualification.

1. Doors & Door hardware: See Drawing A2.2 attached.

Office Doors: D202, 206, 207, 208, 212, 213 changed to lock sets, note on schedule.

- ALL FIRE RATED, ENTRY DOOR CLOSURES TO BE LCN4040XP OR EQUIV.

- ALL CYLINDRICAL LOCKS TO BE SCHLAGE AL SERIES OR EQUIV.

- ALL EXIT DEVICES TO BE 22 SERIES OR EQUIV.

- ALL MEDIUM USE, FIRE RATED CLOSURES 1461 OR EQUIV.

- ALL THRESHOLDS TO BE DRAFT STEEL OR EQUIV.

- ALL WALL STOPS & KICK PLATES TO BE GALLERY HARDWARE OR EQUIV.

2. Windows: Match existing aluminium frame as per specified in drawing A2.2 attached.

3. Ceiling Tile: T-bar Tile - Armstrong Cortega Second Look II - a 24 x 48 with scored line so it

appears like a 2 x 2, or equiv. 2 x 2 lighting proposed in electrical drawings to remain.

4. Millwork specifications: See updated Drawing ID-1 and ID-2 attached.

5. Stairwell treads: See updated Drawing ID-1 and ID-2 attached.

6. Washroom 207,208 mechanical clarification: The upper floor washrooms have been

plumbed, but currently there are no fixtures, finishes and the walls have been framed only.

7. Where is DHWT-2 relocated from? See as-builts, above in area with currently no floor.

8. Are there as‐built drawings for electrical and mechanical? See attached.

9. Stack Vents: The 2 existing stack vents shown on second floor drawings - Contractor to

breakout cost to keep stack vent as-is with additional fin-walls or move as per original

drawings in A2.2.

10. What is the R-value standard for the new roller O/H Doors? Because these O/H doors will be

used for frozen fish storage, the typical R2+ value for a roller O/H door should be sufficient.

11. Will bidders be revealed to the general public? No.

Attachments:

1. Second Floor Plan & Window/Door Schedule 2.2 - Addendum 2 Revision 1 page

2. Interior Design: Finishes Plan ID-1 - Addendum 2 Revision 1 page

3. Interior Design: Elevations & Sections ID-2 - Addendum 2 Revision 1 page

4. As-builts Structural 9 pages

5. As-builts Mechanical 4 pages

6. As-builts Electrical 7 pages

Addendum No.002

FILE: VA1719

# of PAGES: 24

DATE: November 1, 2017 # of Pages

PROJECT: FNHA Office Fit-ups West Kelowna, BC

Page 2: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

GLASS WALL

INFILL FLOOR

FRIDGE

EXIT

12' X 9'12'-0" X 9'-0"

13'-2" X 10'-2

13'-2" X 10'-2"

NEW 45 MIN. FIRE

RATED WALL TO

UNDERSIDE OF

STRUCTURE.

ADDENDUM 2

TILE

ELECT.

PANEL

10'-0" X 12'-0"

INFILL FLOOR @ REMOVED

SHUTTER + ENCLOSURE

INFILL FLOOR @ REMOVED

SHUTTER + ENCLOSURE

6'-0" x 7'-0"

NEW RATED EXIT

DOOR + WALL

NEW OPENING IN

EXISTING STAIRWELL

WALL - PATCH + MAKE

GOOD

GLAZED PARTITION

11'-9" X 12'-8"

11'-9" X 10'-11"

11'-9" X 8'-11"

DN

DN 21 R

EX

IS

TIN

G 1

H

OU

R R

AT

IN

G

NEW RATED EXIT

DOOR + WALL

NEW RATED EXIT

DOOR + WALL

ANTI STATIC

RESILIENT

EXISTING STACK

VENT TO REMAIN

& FRAMED

IN-PLACE

EXISTING STACK

VENT TO REMAIN &

FRAMED IN PLACE

201 202

203 204

D201

B C D

1

2

2'

3

3'

5

4

SCALE: 1/4" = 1'-0"1

A2.1SECOND FLOOR PLAN

D203

D205

D202

D207D208

D206

D209

D210

D211

D212

D213 D214 D215

D216

DW

6" x 16" CHASE

ELEVATOR

D204

STAIR 1202

D217

W4

W4

W4

W3

W3

W3

W4

W4 W4

W4

W4

W4

W4

W4

W3

W3

W5

W5

W5

W5

W5

W5

3'-6

"

6'-3 1/4"

4'-1

1"

2A2.1

2A2.1

FURR OUT DUCTING

16'-0

"20

'-0"

20'-0

"12

'-0"

4'-0

"

5'-2

"

4'-11"

24'-8" 24'-0"

4'-0

"

NOTE: FURR OUT ALL DUCTING

T

R

A

V

E

L

D

I

S

T

A

N

C

E

2

0

.

8

0

m

T

R

A

V

E

L

D

IS

T

A

N

C

E

8

.5

6

m

3'-7 3/4"

EXISTING FIRE

RATED WALL

ADDENDUM 2

DO

OR

TAG

DOOR SCHEDULE

D101

D201

D202

D203

D204

D205

D206

D207

D208

D209

D210

D211

DO

OR

INFO

FRA

ME

TYPE

DO

OR

PAN

EL S

IZE

FIRE RATED ENTRY DOOR

DOUBLE WOOD DOOR

WOOD

36" x 84"

NOTES:

FIRE RATED ENTRY DOOR

FIRE RATED ENTRY DOOR

S/C FLUSH DOOR

FIRE RATED ENTRY DOOR

S/C FLUSH DOOR

S/C FLUSH DOOR

S/C FLUSH DOOR

S/C FLUSH DOOR

S/C FLUSH DOOR

S/C FLUSH DOOR WOOD

36" x 84"

36" x 84"

36" x 84"

(2) 36" x 84"

36" x 84"

36" x 84"

36" x 84"

36" x 84"

36" x 84"

36" x 84"

36" x 84"

SWIN

G /

HA

ND

RH

RHR

RH

LH

LH

RH

PUSH

/ P

ULL

PASS

AG

E SE

T

LOC

K SE

T

PRIV

AC

Y SE

T

DEA

DBO

LT

CLO

SER

THRE

SHO

LD

WEA

THER

STR

IPPI

NG

WA

LL S

TOP

FLO

OR

STO

P

HARDWARE TYPE:

REFER TO SUPPLIER SPECIFICATIONS FORMODEL AND MANUFACTURER & NOTESINCLUDED W/I THIS SCHEDULE

WOOD

WOOD

WOOD

WOOD

METAL

WOOD

METAL

WOOD

METAL

METAL

D212

D213

D214

D215

D216 WOOD

S/C FLUSH DOOR

S/C FLUSH DOOR

S/C FLUSH DOOR

S/C FLUSH DOOR

S/C FLUSH DOOR

36" x 84"

36" x 84"

36" x 84"

36" x 84"

36" x 84"

WOOD

WOOD

WOOD

WOOD

LHR

LH

RH

LH

LH

RH

RH

RH

LH

RHR

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

XX

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

45 MINUTE FIRE RATED

45 MINUTE FIRE RATED

45 MINUTE FIRE RATED

45 MINUTE FIRE RATED

DO

OR

TYPE

B

D217 WOOD 36" x 84"

D102 WOOD 36" x 84"

D103 WOODS/C FLUSH DOOR 36" x 84" RHR XXX

CLOSET2 PANEL BI-FOLD

A

B

B

B

D

C

A

A

A

A

A

A

A

A

A

A

A

A

A

S/C FLUSH DOOR RH XX

D104 METALROLLING GARAGE DOOR 9' x 9'E

D105

X X

METALROLLING GARAGE DOOR 9' x 9'E X X MECHANICAL HAND PULLS

MECHANICAL HAND PULLS

X

X

X

PAN

IC H

ARD

WA

RE

X X

- ALL FIRE RATED, ENTRY DOOR CLOSURES TO BELCN4040XP OR EQUIV.

- ALL CYLINDRICAL LOCKS TO BE SCHLAGE AL SERIES OREQUIV.

- ALL EXIT DEVICES TO BE 22 SERIES OR EQUIV.

- ALL MEDIUM USE, FIRE RATED CLOSURES 1461 OR EQUIV.

- ALL MORTIS CASE LOCK TO BE L SERIES SCHLAGE

- ALL THRESHOLDS TO BE DRAFT STEEL OR EQUIV.

- ALL WALL STOPS & KICK PLATES TO BE GALLERYHARDWARE OR EQUIV.

7'-0

"

3'-0" 6'-0"

3'-0

"3'

-0"

2'-0"

7'-0

"

3'-0"

7'-0

"

LINE OF FINISHED FLOOR

DOOR TYPES

LINE OF FINISHED FLOOR

WINDOW TYPES

5'-0

"

8'-3"

2'-6

"

A B C

3'-0"

7'-0

"

D

10'-0"

10'-0

"

E

4'-4"3'-11" 4'-4"

A B

NOTE:

EXTERIOR WINDOWS TO ALIGN WITHEXISTING STUCCO REVEALS AS SHOWNIN ELEVATION DRAWING A3.1

CONTRACTOR TO CONFIRMMEASUREMENTS PRIOR TOCONSTRUCTION

WINDOW TAG

WINDOW SCHEDULE

201

202

203

204

GLAZING TYPE FRAME TYPE SIZE (R/O)

DOUBLE

DOUBLE

DOUBLE

DOUBLE

MATCH EXISTING 60" x 48"

60" x 97"

60" x 97"

60" x 48"

NOTES:INSECT SCREENS ON ALL OPENERS

OPERABLE AWNING

MATCH EXISTING

MATCH EXISTING

MATCH EXISTING

FIXED W/ OPERABLE AWNING

FIXED W/ OPERABLE AWNING

OPERABLE AWNING

TYPE

B

A

A

B

DRAWING NO:

JOB NO:

DRAWN BY:

CHECKED BY:

FILE NO:

SCALE:

DATE:

SEAL

CONSULTANT

REVISIONDATE

Report all errors and omissions to the Architect.

This drawing is an instrument of service and theproperty of TRTA Architecture Ltd. The use of thisdrawing shall be restricted to the original site forwhich it was prepared and publication thereof isexpressly limited to such use.

ALL CONTRACTORS ARE REQUIRED TO PERFORMTHEIR WORK AND SUPPLY THEIR PRODUCTS INCOMPLIANCE WITH ALL BUILDING CODES ANDLAWS OF THE PROVINCE OF BRITISH COLUMBIA

This drawing must not be scaled.

Verify all dimensions and datums prior tocommencement of work.

ARCHITECTURE LTD.#101, 2903 - VERNON BC V1T 2S7T: 250.545.0784F: 250.545.0730email: [email protected] Tomporowski M.Arch,Architect AIBC / Architect, AAA

T·RTA

VA1719

SEPTEMBER 21, 2017

KF, VR

GT

FNHA

OFF

ICE

FIT-

UPS

FIRS

T N

ATIO

NS

HEA

LTH

AUT

HORI

TY

101-

3535

, OLD

OKA

NA

GA

N H

IGHW

AY

WES

T KE

LOW

NA

, BC

1 JUNE 22,2017

ISSUED FORCLIENT REVIEW

2 AUGUST 30,2017 99% REVIEW

3 SEPT. 05,2017 CORRECTIONS

4 SEPT. 08,2017

ISSUED FOR TENDER /CONSTRUCTION

5 SEPT. 21,2017 REVISION 1

6 OCT.30,2017 ADDENDUM 2

VA1719A2

1/4" = 1'-0"

A2.2

SECOND FLOORPLAN & WINDOW /DOOR SCHEDULES

AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
206
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
205
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
203
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
202
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
204
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
201
AutoCAD SHX Text
MEN
AutoCAD SHX Text
WC
AutoCAD SHX Text
207
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
WC
AutoCAD SHX Text
208
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
209
AutoCAD SHX Text
SERVERY
AutoCAD SHX Text
210
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
211
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
212
AutoCAD SHX Text
WELLNESS
AutoCAD SHX Text
214
AutoCAD SHX Text
MEETING
AutoCAD SHX Text
213
AutoCAD SHX Text
IT SERVER
AutoCAD SHX Text
215
AutoCAD SHX Text
PRODUCTION
AutoCAD SHX Text
216
AutoCAD SHX Text
STORAGE/FUTURE BOARD ROOM
AutoCAD SHX Text
217
Page 3: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

CO

AT

S

COPIER

EXISTING FINISHES TO

REMAIN UNLESS NOTED

OTHERWISE

SHELVING

FRIDGE

COPIER

STAIR 1

105

UP

ELEVATOR

ID2

E1

ID2

E2

ID2

E3

EXISTING FINISHES TO

REMAIN UNLESS NOTED

OTHERWISE

TR1

TR1

WORK

COUNTER

ID2

E7

C1

NEW SECTION OF CARPET TILE-

PROVIDE TRANSITION TO

EXISTING RESILENT

1. THE PAINTING CONTRACTOR IS TO INCLUDE FOR THE PATCHING

AND FILLING OF MINOR MARKS AND DENTS IN EXISTING WALL

SURFACES PRIOR TO PAINTING.

2. PAINTING CONTRACTOR TO SUBMIT DRAW-DOWNS OF ALL PAINT

COLORS/FINISHES, PLASTER FINISH AND COLOR FOR APPROVAL

BY DESIGN CONSULTANT, PRIOR TO COMMENCEMENT OF WORK.

3. FOR ALL DRYWALL PARTITIONS, THE FIRST COAT SHALL BE

PRIMER/SEALER, SECOND AND THIRD COATS SHALL BE ACRYLIC

LATEX EGGSHELL FINISH. SAND LIGHTLY BETWEEN COATS AND

WIPE CLEAN. PAINTER TO EXAMINE ALL SURFACES AND PROVIDE

REPAIR(S) WHERE NECESSARY. UNSATISFACTORY FINISHES

RESULTING FROM IMPROPER PREPARATION WILL BE RECTIFIED

AT PAINTING CONTRACTORS EXPENSE.

4. QUALITY OF WORK SHALL CONFORM TO THE MASTER PAINTERS

AND DECORATOR'S ASSOCIATION STANDARDS FOR PREMIUM

QUALITY OF WORK.

FINISH NOTES

C1

FINISH LEGEND

WALL FINISHES

B1 BASE: 4" Johnsonite black cove base

Extent: Areas with C1, and new walls

CARPET: Bigelow Datum Modular BT284

7879 Basalt (black/brown)

24" x 24" Quarter turn installation

Extent:

C1

P1

P2

PAINT MANUFACTURER GENERAL PAINT

PRODUCT INTERIOR LATEX

COLOUR CL 3104M

COLOUR NAME SEVILLE (BLUE)

FINISH EGGSHELL

P3

PAINT MANUFACTURER DULUX

PRODUCT INTERIOR LATEX

COLOUR #20YY 63/149

COLOUR NAME BRAZIL NUT

FINISH EGGSHELL

PAINT MANUFACTURER GENERAL PAINT

PRODUCT INTERIOR LATEX

COLOUR CLW 1037W

COLOUR NAME STONEY PLAIN

FINISH EGGSHELL

EXTENT WALL, GWB CEILING

CARPET: Bigelow Color Beat (solid)

883 Espresso

24" x 24"

Extent: Accent band

Note:

C2

FLOOR FINISHES

RESILIENT: Marmoleum

Piano 3601 Warm Grey

Extent: Production, washroom, kitchen

R1

PL1

PLASTIC LAMINATE

PL2

LAMINATE MANUFACTURER FORMICA

COLOUR CHALK WHITE S7024T

FINISH TEXTURED

LAMINATE MANUFACTURER ARBORITE

COLOUR RUCHED JUTE R 364 SR

FINISH MATTE

LOCATION: CABINET FACES

PAINT MANUFACTURER General Paint

DOORS PRODUCT INTERIOR LATEX

FRAMES COLOUR CL 3167N

COLOUR NAME Crows Nest (black)

FINISH SEMI GLOSS

P4

STAINLESS STEEL DOUBLE SINK & FAUCET.

Refer to mechanical drawings for specification.

STAINLESS STEEL SINGLE SINK & FAUCET.

Refer to mechanical drawings for specification.

SK1

PLUMBING LEGEND

SK2

EXISTING FINISH: To remain.EX

TRANSITION STRIP:

1

8

" Metal Schluter strip from Carpet to Resilient flooring.

TR1

SW Johnsonite VIRTR-SQ Rubber Tread with Integrated riser for visually

impaired.

Tread – Charcoal 20 with Silver Grey 55 grit tape

Tactile warning pad – Silver Greg 55 squares

Sheet flooring R1

Extent: Stair

FRIDGE

ELEVATOR

ID2

E6

ID2

E4

ID2

E5 TR1

TR1

MICRO-

WAVE

D/W

ACRYLIC

SHOWER

FLASH COVE BASE

FLASH COVE BASE

FLASH COVE BASE

TR1

TR1

TR1

TR1

MATCH

STAIRWELL

PAINT

FINISH

FNHA - KELOWNA

UNIT 101 - 3535 OLD OKANAGAN HIGHWAY

WEST KELOWNA, BC

978 Wellington Drive, North Vancouver, BC, V7K 1K9 T 604 990 7680Gratham/Design/Associates

FINISHES PLAN

ID-1

TRUE NORTH

AutoCAD SHX Text
RECEPTION
AutoCAD SHX Text
100
AutoCAD SHX Text
COPY
AutoCAD SHX Text
101
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
102
AutoCAD SHX Text
MEETING
AutoCAD SHX Text
103
AutoCAD SHX Text
LAB &
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
104
AutoCAD SHX Text
WC
AutoCAD SHX Text
105
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
106
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
107
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
R1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
R1
AutoCAD SHX Text
B1
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
206
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
205
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
203
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
202
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
204
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
201
AutoCAD SHX Text
MEN
AutoCAD SHX Text
WC
AutoCAD SHX Text
207
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
WC
AutoCAD SHX Text
208
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
209
AutoCAD SHX Text
SERVERY
AutoCAD SHX Text
210
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
211
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
212
AutoCAD SHX Text
WELLNESS
AutoCAD SHX Text
214
AutoCAD SHX Text
MEETING
AutoCAD SHX Text
213
AutoCAD SHX Text
IT SERVER
AutoCAD SHX Text
215
AutoCAD SHX Text
PRODUCTION
AutoCAD SHX Text
216
AutoCAD SHX Text
STORAGE/FUTURE BOARD ROOM
AutoCAD SHX Text
217
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P2
AutoCAD SHX Text
C1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
R1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
C1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
C1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
C1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
C1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P2
AutoCAD SHX Text
P1
AutoCAD SHX Text
C1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
C1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
C1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
C1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
C1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P2
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
C1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
R1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
R1
AutoCAD SHX Text
R1
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
R1
AutoCAD SHX Text
R1
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
R1
AutoCAD SHX Text
R1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
SW
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
C1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
C1
AutoCAD SHX Text
B1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
P1
AutoCAD SHX Text
C1
AutoCAD SHX Text
B1
AutoCAD SHX Text
-
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
DATE ISSUED
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
No.
AutoCAD SHX Text
ings shall have precedence over scaled dimensions.
AutoCAD SHX Text
for clarification prior to proceeding. Written dimensions on draw-
AutoCAD SHX Text
Contractor. Discrepancies shall be reported to the Design Consultant
AutoCAD SHX Text
All dimensions and conditions shall be verified on site by the
AutoCAD SHX Text
or utilized in any manner other than for the specific project,
AutoCAD SHX Text
The drawings, specifications, design concept and related details
AutoCAD SHX Text
represented herewith are the exclusive property of Gratham
AutoCAD SHX Text
Design Associates. No part shall be reproduced, copied, disclosed
AutoCAD SHX Text
for which it is intended, without the written consent of Gratham
AutoCAD SHX Text
Design Associates.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
25 August 2017
AutoCAD SHX Text
sg/ts
AutoCAD SHX Text
SG
AutoCAD SHX Text
ISSUED FOR REVIEW
AutoCAD SHX Text
25 AUG 17
AutoCAD SHX Text
Date
AutoCAD SHX Text
Description
AutoCAD SHX Text
1.
AutoCAD SHX Text
ISSUED FOR 99% REVIEW
AutoCAD SHX Text
5 SEPT 17
AutoCAD SHX Text
2.
AutoCAD SHX Text
ISSUED FOR TENDER
AutoCAD SHX Text
21 SEPT 17
AutoCAD SHX Text
3.
AutoCAD SHX Text
ADDENDUM 2
AutoCAD SHX Text
30 OCT 17
AutoCAD SHX Text
4.
AutoCAD SHX Text
1/4"=1'-0"
AutoCAD SHX Text
MAIN LEVEL - FINISHES PLAN
AutoCAD SHX Text
1
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
ID1
AutoCAD SHX Text
SECOND LEVEL - FINISHES PLAN
AutoCAD SHX Text
2
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
ID1
Page 4: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

1'-0" 6"

1 1/2"

1 1/2"

MOUNTING HEIGHT: 5'-4" A.F.F.

SILICONE CAULKING

3

4

" PLYWOOD (PL2)

SHELF

45° MITRE ON

3

4

" PLYWOOD

GABLE. PAINT P1.

1

1

2

" DIA. CHROME

COAT ROD

5'-4"

1

1 2

"

5'-1"

ID2

S1

4'-7

1

4

"

3

1 2

"

FIXED PANEL

PL2

LED STRIP LIGHT

PL1

P1

SK1

PL2

P1

P1

FIXED PANEL

PL1

PL2

FRIDGE

N.I.C.

4"

P1

P1

PL2

B1

SK2

PL2

PL2

FIXED PANEL

PL2

ELECTRICAL PANEL

& CONDUITS.

ID2

S3

ID2

S2

ID2

S4

ID2

S5

ID2

S2

ID2

S6

3'-0"

1'-6"

2'-6"

7'-0"

1'-1

3

4

"

3'-0"

1'-1

3

4

" 1'-1

3

4

" 1'-1

3

4

" 1'-1

3

4

"

2"

1'-11

1

4

" 1'-11

1

2

"

2"

7'-0"

1'-10"

2"

9'-0"

1'-1" 1'-1" 1'-1" 1'-1" 1'-1" 1'-1" 1'-1" 1'-1"

8'-10" 4'-3"

3'-0"

1'-6"

2'-6"

7'-0"

1'-2"

1'-2"

1'-7

1 4

"

2'-10"

1'-2

3

4

" 1'-2

3

4

" 1'-2

3

4

"

2'-0"

MICRO

N.I.C.

1'-1

1

2

" 1'-1

1

2

" 1'-1

1

2

" 1'-1

1

2

" 1'-1

1

2

"

FRIDGE

N.I.C.

1'-2"

1'-2"

PL2

PL1

P1

PL2

PL2

PL2

PL1

P1

P1

COPIER

N.I.C.

B1

PL2

ID2

S8

ID2

S9

ID2

S10

ID2

S3

ID2

S11

3'-0"

B1

PL2

4'-6"

2'-6"

7'-0"

1'-8

3

4

" 1'-8

3

4

"

1'-2"

3'-6

1

4

"

6'-0"

3'-4"

1'-6"

2'-6"

3'-5

1

2

"

7'-5

3

4

"

3'-0"

1'-4

1

4

" 1'-4

1

4

"

5'-5

1

2

"

ANGLED WALL

1'-10"

3'-4

1

2

"

1'-11

1

2

"

3'-0"

1'-6"

2'-6"

7'-0"

1'-2

3

4

" 1'-2

3

4

" 1'-2

3

4

" 1'-2

3

4

" 1'-2

3

4

"

6'-3

1

2

"

1'-2

3

4

"1'-2

3

4

"1'-2

3

4

"1'-2

3

4

"1'-2

3

4

"

6'-3

1

2

"

B1

PL1P1

PL2

PL2

ID2

S11

ID2

S3

3'-6"

OPEN FOR

WASTE AND

RECYCLING

5 EQUAL FRONTS

VOID SPACE

FIXED PANEL

EXISTING

CONDUITS

CABINET

SWING DOOR

EXISTING

ELECTRICAL

PANEL

OPEN TO CONCRETE WALL.

SECURE CABINET AS

REQUIRED.

EXISTING CABINET BEYOND

4"

2'-6

1 2

"

2'-1

1

2

"

3'-0"

4"

1'-6"

2"

2'-6"

1'-1"

4"

6'-10"

1'-10"

2"

1'-1"

1

1 2

"

2'-10

1 2

"

2'-1

1

2

"

3'-0"

4"

1'-2"

1'-9

1 4

"

1'-1"

1

1 2

"

1'-2"

1'-4

1

4

"

1'-0

1

4

"

4"

OPEN FOR

UNDER

COUNTER

FRIDGE. N.I.C.

OPEN FOR

MICROWAVE.

N.I.C.

2'-10

1 2

"

2'-1

1

2

"

3'-0"

4"

1

1 2

"

OPEN FOR

DISHWASHER.

REFER TO

MECHANICAL

DRAWINGS.

1'-6"

2"

2'-6"

1'-1"

4"

2'-6

1 2

"

2'-1

1

2

"

3'-0"

4"

1'-2"

1

1 2

"

1'-2"

1'-0

1

4

"

4"

OPEN FOR

MICROWAVE.

N.I.C.

1'-4

1

4

"

4"

2'-6

1 2

"

2'-1

1

2

"

3'-0"

4"

1'-2"

1

1 2

"

1'-2"

1'-0

1

4

"

4"

OPEN FIXED

SHELF

1'-4

1

4

"

4'-2"

2'-6"

2'-0

1

2

"

4"

7'-0"

4"

6

1 2

"

2'-1

1

2

"

3'-0"

4"

1'-6"

2"

2'-6"

1'-1"

1

1 2

"

1'-0"

1'-0"

FIXED PANEL

PL2

PL1

P1

SK1

DISHWASHER

N.I.C.

PL2

P1

ID2

S7

ID2

S2

ID2

S5

3'-0

"1

'-6

"2

'-6

"

7'-0

"

2'-0" 2'-10"

1'-2

3

4

" 1'-2

3

4

" 1'-2

3

4

"

1'-2

1

2

" 1'-2

1

2

" 1'-2

1

2

" 1'-2

1

2

" 1'-2

1

2

" 1'-2

1

2

" 1'-2

1

2

"

8'-7"

FIXED APRON

4"

1'-1

1

3 4

"6

1 2

"

2'-1

1

2

"

3'-0

"

4"

1'-6

"2

"2

'-6

"

1'-1"

4"

2'-6

1 2

"

2'-1

1

2

"

3'-0

"

4"

1'-6

"2

"2

'-6

"

1'-1"

1

1 2

"

3

1 2

"

FNHA - KELOWNA

UNIT 101 - 3535 OLD OKANAGAN HIGHWAY

WEST KELOWNA, BC

978 Wellington Drive, North Vancouver, BC, V7K 1K9 T 604 990 7680Gratham/Design/Associates

ELEVATIONS & SECTIONS

ID2

AutoCAD SHX Text
ELEVATION - COAT CLOSET 100
AutoCAD SHX Text
E1
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
SECTION - COAT CLOSET 100
AutoCAD SHX Text
S1
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
ELEVATION - LAB AND STORAGE 104
AutoCAD SHX Text
E2
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
ELEVATION - KITCHEN 106
AutoCAD SHX Text
E3
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
ELEVATION - SERVERY 210
AutoCAD SHX Text
E5
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
ELEVATION - PRODUCTION 216
AutoCAD SHX Text
E6
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
ELEVATION - COPY ROOM 101
AutoCAD SHX Text
E7
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
S4
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
S5
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
S6
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
S7
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
S8
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
S9
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
S10
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
S11
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
ELEVATION - SERVERY 210
AutoCAD SHX Text
E4
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
S2
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
S3
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
ID2
AutoCAD SHX Text
-
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
DATE ISSUED
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
No.
AutoCAD SHX Text
ings shall have precedence over scaled dimensions.
AutoCAD SHX Text
for clarification prior to proceeding. Written dimensions on draw-
AutoCAD SHX Text
Contractor. Discrepancies shall be reported to the Design Consultant
AutoCAD SHX Text
All dimensions and conditions shall be verified on site by the
AutoCAD SHX Text
or utilized in any manner other than for the specific project,
AutoCAD SHX Text
The drawings, specifications, design concept and related details
AutoCAD SHX Text
represented herewith are the exclusive property of Gratham
AutoCAD SHX Text
Design Associates. No part shall be reproduced, copied, disclosed
AutoCAD SHX Text
for which it is intended, without the written consent of Gratham
AutoCAD SHX Text
Design Associates.
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
25 August 2017
AutoCAD SHX Text
sg/ts
AutoCAD SHX Text
SG
AutoCAD SHX Text
ISSUED FOR REVIEW
AutoCAD SHX Text
25 AUG 17
AutoCAD SHX Text
Date
AutoCAD SHX Text
Description
AutoCAD SHX Text
1.
AutoCAD SHX Text
ISSUED FOR 99% REVIEW
AutoCAD SHX Text
5 SEPT 17
AutoCAD SHX Text
2.
AutoCAD SHX Text
ISSUED FOR TENDER
AutoCAD SHX Text
21 SEPT 17
AutoCAD SHX Text
3.
AutoCAD SHX Text
ADDENDUM 2
AutoCAD SHX Text
30 OCT 17
AutoCAD SHX Text
4.
AutoCAD SHX Text
AS NOTED
Page 5: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

4D ENGINEERINGSTRUCTURALENGINEERS

Page 6: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

4D ENGINEERINGSTRUCTURALENGINEERS

Page 7: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

4D ENGINEERINGSTRUCTURALENGINEERS

>

> >

>

>

>

>

Page 8: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

4D ENGINEERINGSTRUCTURALENGINEERS

Page 9: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

4D ENGINEERINGSTRUCTURALENGINEERS

Page 10: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

4D ENGINEERINGSTRUCTURALENGINEERS

Page 11: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

4D ENGINEERINGSTRUCTURALENGINEERS

Page 12: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

4D ENGINEERINGSTRUCTURALENGINEERS

Page 13: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

4D ENGINEERINGSTRUCTURALENGINEERS

Page 14: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"
Page 15: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"
Page 16: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"
Page 17: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"
Page 18: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

Er==tt^ - L¿ A¿r¡nD

)l1-'ì i

l, {

..¡

srofiÁô8/sgfrvER

'.ìI :li¡¡,..

ctosto fht $îoltacË

ìlr0t.ô i sËRVÉîl

i3j

4

(s i-

',1.til.1

ii+,,

t05.5,

¡.0$,8

(r)C)-I

O

+F

=z=I

zo

offtcE

roO*h|:z:)

I s.ooari" '-iÊ

6lliå.O

'i

',

uNrr #t 04GROSS FLOOR ARFA:

I,2I B SO,FT,

1".¿{ìitljajll

: j)l)

Stii:l\Ã5ó¡o¡tÂC;r I

üHCE¡:t,¡:;

It -.._. --- -- -- .-. -^ ^-

I

-*1-*{*Ë-ã:-É*.J.

i,iiìi.i:ì:.' : :r.'i¡.:;i:i i:'

:':,:',:, :.1, : r:,:,r j, , -1iìr:,:: ,ii'. ,r.t:ì11. ìr,

Page 19: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

i:j¡' ït'r

stclÁGÈc^ô

ril'. r

CTOSED FIt[ SIGìAtrI ros.o:

t.t

$ tt'-¿;'-ã- -* --

UUoo1z

Stor(AÊÊ/SERVfR

rræ-ri

4i!p

"säâo(,3

äuo2

{s}

rS

:r

,ã,.t ll''l.l'

i{}çu

+F.

t-:

l.'r{ì

þr0

i)t\,

11¿'1"

ll\'\.,/

5ËRVEN

c¡8

:s&

fJ

(r.)O

I

(f

Th

tz3I

zo

i,¡r"Jr{}

oFfrc€

i 105-4ì

8aõo

LOO+Ft-z:)

{ Jtlfódu ¡d:

5 ù¡4 l)ftf,s\li

uNlï #t04GROSS FLOOR AREA.

I ,218 S8,FT,

.t

È¡

ruriG cÂ8

off ic€

IiosrI

rit'.Õ''

5a

cs

s

!

R

Ç:

rt\

t.t ilílltl(ii¡'to5-ì

Z\r*=*'"

i;i II

¡is")- -.'1PROPOSFD TLOOR PiAN - UNIT # ':N4

$Ç(:*: :1.1' . ì't-lGROSS FLOOTì-

i.år'e qtAREA

1 - 1t'nanl

35:jS qd Ckcnogon Avê.. Wesi Kèlo,ì¡/no. S.Ciriy 08, 201 4

sq.fÌ.

aa

{,nli

ir

;:!

(tzE

t?

s*Nfqslcr¡v"f

*¿

&

b'

3.ùô.8

xJlo€Nt05 3

t+ç ì¡,sHft¡¡'

l0&5.¡.3 ll¡û3

zls. 3rã, ¡ere E¡qHUEiTER€TcF^ñ@EorausrEÊHqxroEãtsN,Eoú oFg16ñ ãERv¡ocs

Page 20: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

tlr:t i\,: tjtt\an,t4 !i!:

;f;

r;) :+'¡rrà:+ *rYrr,4.;,ã1

l: *ç"er'lM{ü¡**5r:*:

!,i þk $ra-..*tu t,.tu. |ú"et

¡¡ tu:#rá.::Ðåì4¡s,

/¡¡\ ',áea*d(.**:Flr

*¡4.r4,F1

,'5'ì fuïj-Lwoix li[vAitûl{ - wÁstitìöoM\ 31 , t4i{f i;. { :.lr

$t¡i:¡s' râc*w

./ ä\. Mtil.ïlo!îK EtnvÂTtoN .. KncHfi.,¡r !.,/ t l- t;1';i '

rJ|lj ¿*i(À¡ir.í;Ål{ rl,/il

I'TÈ¡rulffi

Lå'ffi

s(þ

ai:':::',

. i:i|. åâri h

,,?'\ s:ÎÊ ÊtÂN / LÖ(:AIÐN prÅN..::.. "

ii*,#¡ß 1ú,15ù)fám¡i , i:tì5 aa s t:npa. l¡;d r}ì'i.'i *q.e!l4s: l

&ffi¡{]1Àeffi l.i!rir)' ;rliijri\ir; r+(!:.iìîi¡ a)

,í#.;*. (\rfl".Ì.rr:. , J. . :

i* t¡,È, rrríl-j..{ïrj i

¡IYt*"?*t:*.,,,.. ¿*rsärï$t,,'.i

' ;)i;;;:'þ;,'tr . .fÞ - wi'-z

,''iù sFfiiclN þF.ïÁl:. - p&?itltotJ wÂti_r¡ rr:e:ì,'::.:.tr

:ajirr::;1,Cl*fRti

:i: I

1::l

t-,,l

?-Íi

'?::

:?<j

3

.2

vsU

g

i.Jftrli i í)/jrirs.riv,lii¡cr

a)

s:>llii, . al!:iit:M,i. l

(i'. ¡ ¡{)tra;F d;rr.r;4t

Èxiiä)

i¡iM,tr i lrir: i:Ji,íÌi

*i \ fl4Ail,,¡ i:i..fx)Ê ptÂt¡ . iJfçli trl.l'¡i !L*!¡.r!

' 1.;)

'j,i':i^;

>Í.. Ìi.1.: d di;.t{i¡, l:aì ¡ß.r ,rrl+¡,,i' \ , rî\ll j f.{i I!:, ìi4!1r{r;fi)$1411.tt'],ì¿ .>i

,¡:4 !.rir¡it::¡,: r,1 .:¡

/.!Àit,!! i)'Íþi;ì1,\

-¡¡!t ::: ,.:,¡¡!:d{ ìti.tJiinçr!:ì: .¡),/f (:: t:

lÞ: r\1 !f ta¡fllt¡ 1

rí a,iî{{+r,¡ r¡jxrÀ,i,

si! *-i 1j{_1Ê 1¡ i rií l{

r,..t,í,, ril$ : i.i.1t' a: I

.J¡r"is.i:, 1;1?rii:â a2t

nñiwj*eá¿

A1

'{*i

jry

r \il;..J

i"--it:Ì.iLÌì........t

fl;-x

1i-"i

'ii

H

Ti'*ìi!;'..r-:i.

ï*t

" r'. rìi:l:i'r{îell c[l"lNG ptÄN - uì.ìjT ic¿

i A. . l)rii :_.1,, : rl\ r': ',

i¡;.".

Page 21: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

(3)

(J

cú)

ú)o*F.z:

-oJ/r'ro'7(a)

,,sj ,i

(.}lû:wily i 'jÌ:nuli I

.lf)35 ()d Oto¡lcìÍ¡Jf I Àve., y1Êrst l(.Juyl r¡.¡. ß (:

.ruly Û¡J, 2i| 4

(c)I

(o'¿4' l"

^¡r- IU

l'.til

'tLìe¡

=

a€rJt,ÍU

i

4--

t0

IJ

LiIãø)

u1,.,

t

:?t.idt?..

t: t'

4Uså

l)

Stolr¡¡;¡¡sfpvrlr;1ì

.t îL

¿;ca+7nxîc118cé

lrlt i

)

+ûiO$D f ltt sÍ(,l:¿^cE

t,l5 c,

,.ß,J*at,

lil' t'

)fr r(.:f

to5,¡

ptg¿ØAltUNIT # I C4

?IìOSS FLCOR AR[A;r,2 ìB SQ,rT, h

.Ì thr.

ÞdJttJ

i:i.l : i':¡i ì;:05 :

tP{iOPOS|:D

'-i.OCl? Pl:\N - lli.JlT # 1fi4

I

tft

i.t

.t

f.

i)()

(\,

1

øI

t:ii!¡tìi,llr

:?'

T

¿ð.å

lrt¡t{

¡f

rl¿ vr¡ilftfr0! 5

t (r)

t

(J

rtF

.:rI

z

l

i

)l

i.ri\l

J U(ô,t

Ít.,í) ø

li: ¡(;l*l.lr05 3

fdÍ r,Â8

4)',

,i

i

I

! tuouf irl"r5O¡nC

4V

lk";l

T

øüû¡ô,l

:it ii i vaì€ia, {a$É

,] , {l

'l¡rJ

..ll'()"

t *t";,2ilÚ?

Y

a

:,î

T

I

éj:' ',.}

tl"ì

lri;llí

tti

øI

ScûlB: lr'4' | ù'û*os$ f:t()()lÂnFA

1,210 sc¡.f|.

Bttr ^¿r

ltjrfil¡ rr {

qì:ì)v(.:f¡tt:: tiI

.

t:

:

zeñ zt5,3çre ËCHUSTEF!Ë:rra*(ôur¡r ¡r-¡r¡r.Jl tatrr1)::.i¡{N,ãFy oËBìri}r e¿tavi.:r:e

Page 22: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

Spec's for Tl in unit 104 at Gateway One

ELECTR|CAt

-Plugs as per print

-Standard 3 lamp 2X4lay in t-bar fixtures through out

-optional price to be provided for deep cell parabolic fixtures

-all plugs and switches to be Decora style

-all data and communication by others (tenant)

-security system by others (tenant)

PIU.MBING/HVAC

-HVAC distribution as required by code

-ducting as required for t-bar ceiling complete with diffusers

-ceiling space to be used as return aír plenum

-supply and install complete with ducting one bathroom exhaust fan

-relocate and/or installthermostat as per drawings

-supply and install all rough-in as required for bathroom and kitchen

-supply and install one standard commercial H/C toilet as required by code

-supply and install one wall hung sink and single lever tap as per code for HIC bathrooms

-supply and install standard stainless steel single bowl sink c/w standard single lever tap

-supply and install one 10 gal electric (120v) HWT to be located above the bathroom t-bar

-balance complete HVAC when complete

FTOORING

-front reception area up to front counter to be ceramic tile standard grade

-closed file storage to be pa¡nted concrete

Page 23: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

-kitchen area to be ceramic tile

-bathroom to be ceramic tíle

-offices, remainder of reception area, hallway, storage/server area to be glue down carpet 20oz

MrLrwoR(

-kitchen cabinets to be standard over the counter cabinets

-shelving in fíle storage room to be made on site shelving from good one side plywood

-all other millwork by others (tenant)

CEILINGS and WA[[S

-all ceilings to be standard t-bar with 2'x4' grid

-tiles to be standard 2'x4' tile Armstrong or similar

-ceiling to be insulated for sound above tiles

-walls around offices to be insulated for sound

-walls around bathroom to be insulated for sound

DOORS

-doors to be standard 3-0x6-8 paint grade doors solid core doors

-optional price for solid core stain grade door

-door casings to be paint grade flat stock 3 %"

-baseboards to be paint grade flat stock4/,"

PAINTING

-price to include complete painting

-paint colors to be determined by tenant

-optional price to stain doors if stain grade door are used

DEMISING WAttS

-demising wall shall be t hour fired rated consisting of 6" metal 20 gauge stud, 5/8 fire guard both sides

with deflection board at top, taped to paint finish, fire caulked as per building/fire codes.

Page 24: Addendum No - First Nations Health Authority · w4 w4 w4 w3 w3 w3 w4 w4 w4 w4 w4 w4 w4 w4 w3 w3 w5 w5 w5 w5 w5 w5 3'-6" 6'-3 1/4" 4'-11" 2 a2.1 2 a2.1 furr out ducting 16'-0" 20'-0"

-opt¡on prices to be provided for lnsulating demising wall one price for R20 insulation and one price forRoxul sound insulation.

-demising wall price to be broken out from Tenant improvement price (separate contract)