additional form atp (hti) rbs optical template rev1
DESCRIPTION
TELECOMTRANSCRIPT
![Page 1: Additional Form ATP (HTI) RBS Optical Template Rev1](https://reader036.vdocuments.net/reader036/viewer/2022081512/5695d4dd1a28ab9b02a312c0/html5/thumbnails/1.jpg)
STANDARD PRACTICE FOR ACCEPTANCE PROCESS
OPTICAL POWER MEASUREMENT & INSPECTION TEST
DOCUMENT NO. :
Testing Report
General InformationSite ID & Site Name CPRI cable DescriptionMulti Mode / Single ModeSystem BTS type 2G / 3G SFP Description
Optical Power & Attenuation measurement by OMC/OSS system ToolsFIBER#
OPTICAL LENGTH(m) ATTENUATION(db) Result R E M A R K SFIBER# LABEL
1 Sector 1 #TX Err:502 Err:502 Err:502 Pass / Fail2 Sector 1 #RX Err:502 Err:502 Err:502 Pass / Fail3 Sector 2 #TX Err:502 Err:502 Err:502 Pass / Fail4 Sector 2 #RX Err:502 Err:502 Err:502 Pass / Fail5 Sector 3 #TX Err:502 Err:502 Err:502 Pass / Fail6 Sector 3 #RX Err:502 Err:502 Err:502 Pass / Fail
Optical power & Attenuation measurement by Optical ToolsFIBER#
OPTICAL LENGTH(m) ATTENUATION(db) Result R E M A R K SFIBER# LABEL
1 Sector 1 #TX 70 Pass / Fail2 Sector 1 #RX 70 Pass / Fail3 Sector 2 #TX 70 Pass / Fail4 Sector 2 #RX 70 Pass / Fail5 Sector 3 #TX 70 Pass / Fail6 Sector 3 #RX 70 Pass / Fail
Optical Cleanness inspection Test by Optical ToolsFIBER#
OPTICAL Core Result R E M A R K SFIBER# LABEL
1 Sector 1 #TX Core 1A Pass / Fail Pass / Fail Pass / Reject2 Sector 1 #RX Core 1B Pass / Fail Pass / Fail Pass / Reject3 Sector 2 #TX Core 2A Pass / Fail Pass / Fail Pass / Reject4 Sector 2 #RX Core 2B Pass / Fail Pass / Fail Pass / Reject5 Sector 3 #TX Core 3A Pass / Fail Pass / Fail Pass / Reject6 Sector 3 #RX Core 3B Pass / Fail Pass / Fail Pass / Reject
Inspection Summary
ZoneDiameter Defects Scratches Attachement :
Inner Outer Result Result - OMC/OSS Query ResultZone_A 0.000 25.000 Pass/Reject Pass/Reject - Capture of Optical Power Meter (OPM) Test ResultZone_B 25.000 120.000 Pass/Reject Pass/Reject - Capture of Optical Cleanness Inspection Test ResultZone_C 120.000 130.000 Pass/Reject Pass/RejectZone_D 130.000 250.000 Pass/Reject Pass/Reject
ACCEPTANCE PROCESS BY : VERIFIED AND APPROVED BY PT. HUAWEI SERVICES
VENDOR Construction & Installation Field Operation(For ATP with contractor and handover to Field Operation)
Name Date & Signature Name Date & Signature Name Date & Signature
Optical power BBU side/
(0.1microwatt/dbm)
Optical power RRU side
(0.1microwatt/dbm)
for Multi-mode CPRI optical cable 50m-150m,
ATTENUATION Request max ≤2dB
Optical power BBU (dbm)
Optical power RRU (dbm)
for Multi-mode CPRI optical cable 50m-150m,
ATTENUATION Request max ≤2dB
Optical cleanness on BBU
Optical cleanness on RRU
![Page 2: Additional Form ATP (HTI) RBS Optical Template Rev1](https://reader036.vdocuments.net/reader036/viewer/2022081512/5695d4dd1a28ab9b02a312c0/html5/thumbnails/2.jpg)
Optic Clean sector 1 Tx (on BBU) Optic Clean sector 1 Rx (On BBU) Outpout Power Optic sector 1 Tx (On BBU)
Optic Clean sector 1 Tx (On RRU) Optic Clean sector 1 Rx (On RRU) Output Power Optic sector 1 Tx (on RRU)
![Page 3: Additional Form ATP (HTI) RBS Optical Template Rev1](https://reader036.vdocuments.net/reader036/viewer/2022081512/5695d4dd1a28ab9b02a312c0/html5/thumbnails/3.jpg)
Outpout Power Optic sector 1 Tx (On BBU)Outpout Power Optic sector 1 Rx (On BBU)
Output Power Optic sector 1 Tx (on RRU) Output Power Optic sector 1 Rx (on RRU)
![Page 4: Additional Form ATP (HTI) RBS Optical Template Rev1](https://reader036.vdocuments.net/reader036/viewer/2022081512/5695d4dd1a28ab9b02a312c0/html5/thumbnails/4.jpg)
Optic Clean sector 2 Tx (on BBU) Optic Clean sector 2 Rx (On BBU) Outpout Power Optic sector 2 Tx (On BBU)
Optic Clean sector 2 Tx (On RRU) Optic Clean sector 2 Rx (On RRU) Output Power Optic sector 2 Tx (on RRU)
![Page 5: Additional Form ATP (HTI) RBS Optical Template Rev1](https://reader036.vdocuments.net/reader036/viewer/2022081512/5695d4dd1a28ab9b02a312c0/html5/thumbnails/5.jpg)
Outpout Power Optic sector 2 Tx (On BBU)Outpout Power Optic sector 2 Rx (On BBU)
Output Power Optic sector 2 Tx (on RRU) Output Power Optic sector 2 Rx (on RRU)
![Page 6: Additional Form ATP (HTI) RBS Optical Template Rev1](https://reader036.vdocuments.net/reader036/viewer/2022081512/5695d4dd1a28ab9b02a312c0/html5/thumbnails/6.jpg)
Optic Clean sector 3 Tx (on BBU) Optic Clean sector 3 Rx (On BBU) Outpout Power Optic sector 3 Tx (On BBU)
Optic Clean sector 3 Tx (On RRU) Optic Clean sector 3 Rx (On RRU) Output Power Optic sector 3 Tx (on RRU)
![Page 7: Additional Form ATP (HTI) RBS Optical Template Rev1](https://reader036.vdocuments.net/reader036/viewer/2022081512/5695d4dd1a28ab9b02a312c0/html5/thumbnails/7.jpg)
Outpout Power Optic sector 3 Tx (On BBU)Outpout Power Optic sector 3 Rx (On BBU)