A D VA N TA G E S
• Rated to 20,000+ psi (1,400+ bar)
• Tested to 30,000 psi
• Auto-adjusting ZDV connection
• Intended for many repeat uses
• No more cut-off and replacement
of swaged ferrules
PEEK:
Proven sealing ability
beyond 20,000 psi
(1,400 bar).
Titanium:
Enables the swage to be
released and reset.
Intended for many
repeat connections.
titanium hybrid ferrule
The Foundation of the EXP Family
Patents Pending
![Page 3: ADVANTAGES Rated to 20,000+ psi (1,400+ bar) Tested to 30,000 psi Auto-adjusting ZDV connection Intended for many repeat uses No more cut-off and replacement](https://reader035.vdocuments.net/reader035/viewer/2022070306/5519ca4c5503468b0c8b4588/html5/thumbnails/3.jpg)
HAND-TIGHT
hand-tight to 8,700+ psi
wrench-tight to 20,000+ psi
A D VA N TA G E S
• Connects between any 10-32 or 6-40 port
• 1/16 and 1/32 options available
• Rated to 20,000+ psi (1,400+ bar)
• Tested to 30,000 psi
• Auto-adjusting ZDV connection
• Intended for many repeat uses
• No more cut-off and replacement
of swaged ferrules
Patents Pending
fitting system
HEX HEAD
rated to 20,000+ psi
![Page 4: ADVANTAGES Rated to 20,000+ psi (1,400+ bar) Tested to 30,000 psi Auto-adjusting ZDV connection Intended for many repeat uses No more cut-off and replacement](https://reader035.vdocuments.net/reader035/viewer/2022070306/5519ca4c5503468b0c8b4588/html5/thumbnails/4.jpg)
stem filter
A D VA N TA G E S
• Approved for use at 20,000+ psi (1,400+ bar)
• Hand-tight and wrench-tight configuration
• Reusable holder intended for many repeat uses
• Auto-adjusting ZDV connections
• Low-dispersion cartridges
• Custom volumes/porosities available
• Ultra-low .27 µL total swept volume
Patents Pending
![Page 5: ADVANTAGES Rated to 20,000+ psi (1,400+ bar) Tested to 30,000 psi Auto-adjusting ZDV connection Intended for many repeat uses No more cut-off and replacement](https://reader035.vdocuments.net/reader035/viewer/2022070306/5519ca4c5503468b0c8b4588/html5/thumbnails/5.jpg)
A D VA N TA G E S
• Approved for use at 20,000+ psi (1,400+ bar)
• Hand-tight filter replacement - NO TOOLS!
• Depth filtration maximizes capacity
• Auto-adjusting ZDV column connection
• Custom volumes/porosities available
• Low-volume, low-dispersion cartridges
• Hardened stainless steel end cap eliminates galling
• 1.4 µL total swept volume
pre-column filter
Patents Pending
![Page 6: ADVANTAGES Rated to 20,000+ psi (1,400+ bar) Tested to 30,000 psi Auto-adjusting ZDV connection Intended for many repeat uses No more cut-off and replacement](https://reader035.vdocuments.net/reader035/viewer/2022070306/5519ca4c5503468b0c8b4588/html5/thumbnails/6.jpg)
stem traps
EXP stem holder EXP fittingdisposable stems
EXP Stem Trap Kit
A D VA N TA G E S
• Hand-tight and wrench-tight configurations
• Intended for many repeat uses
• Auto-adjusting ZDV connection
• Rated to 20,000 psi
• Many chemistries available
including custom packing
• Available in bed volumes
from 0.17ul to 2.6ul
• Low volumePatents Pending
![Page 7: ADVANTAGES Rated to 20,000+ psi (1,400+ bar) Tested to 30,000 psi Auto-adjusting ZDV connection Intended for many repeat uses No more cut-off and replacement](https://reader035.vdocuments.net/reader035/viewer/2022070306/5519ca4c5503468b0c8b4588/html5/thumbnails/7.jpg)
EXP in-line holder
A D VA N TA G E S
• Hand-tight trap replacement - NO TOOLS!
• Rated to 20,000+ psi (1,400+ bar)
• Uni-directional cartridge
• Auto-adjusting ZDV connections
• Custom packing available
• Bed volumes from 4 µL to 100 µL
• Hardened stainless steel end
cap eliminates galling
EXP direct connect holder
trap columns
Patents Pending
![Page 8: ADVANTAGES Rated to 20,000+ psi (1,400+ bar) Tested to 30,000 psi Auto-adjusting ZDV connection Intended for many repeat uses No more cut-off and replacement](https://reader035.vdocuments.net/reader035/viewer/2022070306/5519ca4c5503468b0c8b4588/html5/thumbnails/8.jpg)
A D VA N TA G E S
• Hand-tight guard replacement - NO TOOLS!
• Hardware rated to 20,000+ psi (1,400+ bar)
• Packed guard rated for routine use to 15,000 psi
(1,000 bar)
• 1.4 μL Swept Volume (excluding packed bed)
• Hardened stainless steel end cap eliminates galling
• Low-volume, low-dispersion cartridges
• Auto-adjusting ZDV column connection
• Custom packing available
guard columns