Page 1: Aet catalog 2012

2012 Product Catalog

Page 2: Aet catalog 2012
Page 3: Aet catalog 2012

provided by Saving Oahus Solar.

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 3

Table of Contents

Content Page

AE Series Collectors 4-5

MSC Series Collectors 6-7

Mounting Hardware 8-9

Storage Tanks 10-11

Drainback Reservoirs 12-13

Pumps 14-15

Controls and Misc 16-17

System Comparison 18-19

DX System 20-21

DB System 22-23

DBS System 24-25

DX Retrofit Kit 26-27

Indirect Pressurized Glycol System 28-29

Indirect Pressurized SPS 30-31

Indirect Pressurized Glycol (PV) 32-33

Direct Pressurized System 34-35

Direct Pressurized (PV) 36-37

Thermosiphon System 38-39

Pool Panels 40-45

Order Form 46

Photo on cover provided by: Aegis Solar, FLS Energy, and Solar Service, Inc. Opposite page photo

Page 4: Aet catalog 2012

AE Series “Flat Plate” Solar Thermal Collectors, manufactured in the United States by Alternate Energy Technologies (AET), are designed to meet the needs of any system from 30 to 50,000 gallons for use in hot water, space heating, air conditioning, and industrial process heat systems.

Technical InformationGlazing: 1 sheet of High-T glass, 1/8” or 5/32” thick with 0.01% iron oxide content. Transmittance >90.0% Glazing Gasket: EPDM Channel with molded cornersInsulation: 1-¼” Foil-faced poly-isocyanurate board insulation (R-10) ¾” Foil-faced poly-isocyanurate board in sidewalls and under headers. (R-6)Frame Wall and Batten: 6063 T6 Aluminum extrusion (1/8” wall) Electrostatic paint finish and an integral mounting systemBacksheet: 0.019 stucco embossed aluminum sheet MB-40 bronze, pop-riveted to frame wallFasteners: Aluminum and 18-8 stainless steel, black oxide coated for aesthetics.Absorber Plate: Exclusively manufactured by Thermafin Manufacturing. All copper fin and tube construction. High frequency forge welded for permanent bond between tube and sheet. No soldered or crimped joints to fail from expansion and contraction. 30-year warranty on fin-to-tube joint.Absorber Coating: Crystal Clear Selective Coating:

Absorptivity: > 0.96Emissivity: < 0.08

Rated: Individually pressure tested to 85psi to ensure qualityDesign Life: 30 YearsFlow Rate: 0.5 to 1.8 GPM recommendedWarranty: 10 year

AE SERIES COLLECTORS

4

Suncatcher of Atlanta

Innovative Power Solutions

Page 5: Aet catalog 2012

WT (lbs) Part # Description 153 AE-40 4’ X 10’ Collector (commercial use)

113 AE-32 4’ X 8’ Collector 99 AE-28 4’ X 7’ Collector 90 AE-26 4’ X 6.5’ Collector 84 AE-24 3’ X 8’ Collector 74 AE-21 3’ X 7’ Collector

AE-Series Mounting HardwareDetails on page 8

WT (lbs) Part # Description 2.5 AE-MH Standard Mount 2 AE-FM Flush Mount 1 AE-RM Rack Mount

.5 ft E1022 Strut 1” X 1” Square Tube per Foot 3 AE-MHX Hurricane Mounts

AE Series CollectorsAnd Mounting Hardware

Cardinal Heating and Air conditioning

Saving SunshineSuncatcher of Atlanta

Sustainable Energy Solutions

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 5

All AET Collectors are manufactured in America and are Certified SRCC OG100 and FSEC, which qualify for Federal Tax Credits, as well as ARRA.

Page 6: Aet catalog 2012

WT (lbs) Part # Description 159 MSC-40 4’ X 10’ Collector 133 MSC-32 4’ X 8’ Collector 120 MSC-28 4’ X 7’ Collector 102 MSC-26 4’ X 6.5’ Collector 96 MSC-24 3’ X 8’ Collector 82 MSC-21 3’ X 7’ Collector

MSC-Series Mounting HardwareDetails on page 8

WT (lbs) Part # Description 3 MSC-MH Standard Mount

1 MSC-FRM Flat Rack Mount

Saving Ohaus Solar

Saving Ohaus Solar Saving Ohaus Solar

Electratech

MSC Series Collectorsand Mounting Hardware

All AET Collectors are manufactured in America and are Certified SRCC OG100 and FSEC, which qualify for Federal Tax Credits, as well as ARRA.

6

Page 7: Aet catalog 2012

Saving Ohaus Solar

Morning Star Series “Flat Plate” Solar Thermal Collectors, manufactured in the United States by Alternate Energy Technologies (AET), are designed to meet the needs of any system from 30 to 50,000 gallons with hot water, space heating, air conditioning, and industrial process heat.

Technical InformationGlazing: 1 sheet of High-T glass with low iron content, .01% iron oxide, thickness of 1/8’ or 5/32” for MSC-40. Transmittance >90.0%Glazing Gasket: EPDM Channel with molded cornersInsulation: 1-¼” Foil-faced poly-isocyanurate board insulation (R-10) ¾” Foil-faced poly-isocyanurate board in sidewalls and under headers. (R-6)Frame Wall and Batten: 6063 T5 Aluminum extrusion with an anodized bronze finish integral mounting systemBacksheet: 0.019 stucco embossed aluminum sheet MB-40 bronze, pop-riveted to frame wallFasteners: Aluminum and 18-8 stainless steel, black oxide coated for aestheticsAbsorber Plate: Exclusively manufactured by Thermafin Manufacturing. All copper fin and tube construction. High frequency forge welded for permanent bond between tube and sheet. No soldered or crimped joints to fail from expansion and contraction. 30-year warranty on fin-to-tube joint.

Absorber Coating: Crystal Clear Selective Coating:

Absorptivity: > 0.96 Emissivity: < 0.08

Rated: Individually pressure tested to 85psi to ensure qualityDesign Life: 30 YearsFlow Rate: 0.5 to 1.8 GPM recommendedWarranty: 10 year

Island Solar

Saving Ohaus Solar

MSC SERIES COLLECTORS

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 7

Page 8: Aet catalog 2012

AE-MHStandard Mount

(Universal, triangle, flush/tilt mount)

Package contents

Package contents

Package contents

Mounting Options

AE-RMRack Mount

AE-FM Flush Mount

(Fixed mount)

Mounting Hardware

8

Page 9: Aet catalog 2012

Package contents

Package contents

MSC-MHStandard Mount

(Universal, triangle, flush/tilt mount)

MSC-FRMRack Mount

(Flat)

When ordering collectors make sure you have the appropriate mounting hardware. If you have questions about mounting options please refer to the collector brochures and spec sheets on www.aetsolar.com. Our sales staff is also available to assist in all your sunny endeavors.

Package contents

MSC-FM Flush Mount

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 9

Page 10: Aet catalog 2012

Storage Tanks

Free Flow Thermosiphon Tanks

WT (lbs) Part # Description102 FF-50 50 Gal Glass Lined No Element 93 FF-50 SS 50 Gal Stainless Steel with Element 135 FF-80 SS 80 Gal Stainless Steel with Element

OST Series Tanks

WT (lbs) Part # Description196 OST-80TCSC 80 Gal Top/Side Connect Element 289 OST-120TCSC 120 Gal Top/Side Connect Element

Double wall heat exchanger tanks

WT (lbs) Part # Description 212 TM-80HE-1 80 Gal Tank with Heat Exchanger 365 TM-120HE-1 120 Gal Tank with heat Exchanger

Stainless Steel tanks with SS heat exchanger

WT (lbs) Part # Description 115 TM-60SS-HE 60 Gal Stainless Steel with SS HX 146 TM-80SS-HE 80 Gal Stainless Steel with SS HX 215 TM-120SS-HE 120 Gal Stainless Steel with SS HX

10

Page 11: Aet catalog 2012

50 and 80 gallon sizes

Thermosiphon (free flow) systems only

Horizontal tank for natural convection

5 year warranty

No heat exchanger, storage onlyGlass lined80 and 120 gallon sizesUsed in DX, D, and DPV systems6 years warranty, with 12 year upgrade option

Top and/or side port connections

Wrap around heat exchanger double wallGlass lined80 and 120 gallon sizesUsed in DB, I, IPV systems6 year warrantyTop port connect, side heat exchanger connect

Submerged stainless steel heat exchanger (single wall)Constructed of 316L stainless steel with a durable plastic exterior shell which prevents rusting & denting60, 80, and 120 gallon sizesUsed in DBS system10 year warrantyAll side port connections allowing for hidden plumbing

*

**

*

******

****

**

**

****

All OST and TM tanks contain one backup heating element.For spec sheets please visit our website

Free Flow

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 11

OST Tanks

TM Tanks

TM-SS Tanks

Page 12: Aet catalog 2012

Drainback Tanks Without Heat Exchanger

WT (lbs) Part # Description 39 DB-10C Drainback Reservoir 10 Gal SS58 DB-15C Drainback Reservoir 15 Gal SS60 DB-20 Drainback Reservoir 20 Gal SS

Drainback Tanks With Heat Exchanger

WT (lbs) Part # Description 49 DB-10-10XC Drainback Reservoir 10 Gal SS

with 10 S.F. Heat Exchanger68 DB-15-15XC Drainback Reservoir 15 Gal SS

with 15 S.F. Heat Exchanger70 DB-20-20X Drainback Reservoir 20 Gal SS

with 20 S.F. Heat Exchanger

Drainback Reservoir

All reservoirs come with site glass, fittings, & a pressure relief valve. All 10 gallon reservoirs come with a tank stand.

For spec sheets please visit our website 12

Page 13: Aet catalog 2012

The heat exchanger is unique in its design of containing eleven fins per inch that allow for the maximum amount of surface area for the heat exchange process. The EagleSun Drainback reservoir provides an 98% heat transfer, which is the highest on the market today.

(DX) Drainback Reservoir

To Solar

From StorageTo Storage

Trufin® Heat Exchanger

From Solar

Heat Exchangers

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 13

Page 14: Aet catalog 2012

* Add flanges: Cast iron flanges should be used with cast iron pumps and stainless steel flangesshould be used with stainless steel pumps. Flanges are listed on the opposite page.

Pumps

Taco (AC) PumpsWT (lbs) Part # Description

5 CP-003ST4 1/40 HP SS Pump, Thrd Flow 0-6 GPM, Head 0-5ft

5 CP-006B4 1/40 HP Bronze Pump, Swt Flow 0-10 GPM, Head 0-9ft

8 CP-008F* 1/25 HP Cast Iron Pump, Flow 0-1 4 GPM, Head 0-16ft

8 CP-008S* 1/25 HP SS Pump, Thrd Flow 0-14 GPM, Head 0-34ft

10 CP-009SF* 1/8 HP SS Pump, Thrd Flow 0-8 GPM, Head 0-34ft

10 CP-009F* 1/8 HP Cast Iron Pump, Flow 0-8 GPM, Head 0-34ft

11 CP-009VT5* Variable Speed Cast Iron w/ Built in Control & Sensors

26 CP-SPS EagleSun Solar Pumping Station: Built in Control, Flow Meter, 2 Thermometers, Air Vent, Insulation, etc.

14

Page 15: Aet catalog 2012

Taco Flanges(To go with pumps on

opposite page)

WT (lbs) Part # Description 2 110-251S 3/4” Stainless Steel 2 110-251G 3/4” Cast Iron Flanges Grey 2 110-251 3/4” Cast Iron Flange Green 2 110-251B 3/4” Bronze Flange 3 IFS-50 1/2” Webstone Isolation Flange 3.5 IFS-75 3/4” Webstone Isolation Flange

DC Pumps

WT (lbs) Part # Description 4.5 CP809-24 24V DC March Pump4.5 CP809-12 12V DC March Pump

PV Modules (for DC Pumps)

WT (lbs) Part # Description 6 PV-10 10 Watt Module

6 PV-20 20 Watt Module

Other pump and flange sizes are available. Please inquire with the AET sales staff for more information.

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 15

Page 16: Aet catalog 2012

Roof Flashing Kits

WT (lbs) Part # Description

1.5 RF-50 Roof Flashing W/ 1/2” Coolie Hat

1.5 RF-75 Roof Flashing W/ 3/4” Coolie Hat

Controls

WT (lbs) Part # Description

3 DTC-GL30-LCO Goldline GL30 Diff Temp Control w/ Sensors & LCO

11 CP-009VT5 Taco Variable Speed Pump w/Built in Diff Temp Control

Miscellaneous Components

WT (lbs) Part # Description

.5 T-60 Thermometer, 35°-250°F, 1/2” MPT

.5 TPRV T&P valve, 150 PSI, 3/4” MPT

.5 S-10 Bolt/Strap-On Sensor, 10K Thermistor

.5 FM75S Flow Meter 1-10 GPM

Controls and Components

16

Page 17: Aet catalog 2012

Miscellaneous Components

WT( lbs) Part # Description

.5 AVC-417 Air/Coin Vent, 125 PSI, 1/8” MPT

1.5 AM101T Anti Scald Mixing Valve, 3/4” FPT

.5 AV-150 Air Vent, 150 PSI, 1/4” MPT

.5 BD-50 Boiler Drain, 1/2” MPT

.5 BD-75 Boiler Drain, 3/4” MPT

.5 BV-50 Ball Valve, 2 Way, 1/2” Sweat

.5 BV-75 Ball Valve, 2 Way, 3/4” MPT

.5 CV-50 Maxi-Flow Spring Check Valve, 1/2” swt

.5 CV-75 Maxi-Flow Spring Check Valve, 3/4” swt

.5 ET-20 Expansion Tank, 2.0 Gal, 1/2” MPT

.5 PG100 Pressure Gauge, 100 PSI, 1/4” MPT

.5 PGS-10 “Immersion” Sensor, 10K Thermistor, 1/2” MPT

.5 PR-150 Pressure Relief Valve, 150 PSI, 3/4” MPT

Controls and Components

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 17

Page 18: Aet catalog 2012

Pros: Most efficient and least expensive active solar systemRequires only one tank and one pumpRequires low head pump due to pressurized system designCan use 12/24 volt pump with PV module for hot water without any electricity

Cons:Contains problematic components prone to failure: specifically freeze valve, air vent, pressure relief valve, check valveNot always reliable due to overheating and freezingSystem failures require professional service callShouldn’t be installed anywhere where freezing occursProne to scaling corrosion due to potable water running through collectorsNot recommended for use with hard water

System Comparisons: Learn the different systems AET has to offer through our residential brand EagleSun. Make an informed decision on which system is best for you and your customer. From the direct pressurized, indirect pressurized, and drainback systems AET can help with all your hot water needs in any climate. Also, AET collectors can be used for radiant floor and space heating in northern climates.

**

**

*

****

*18

Page 19: Aet catalog 2012

Pros: Requires only one tank and one pump System is suited for applications where sloped piping is not possibleProtects from freezingRequires low head pump due to pressurized system designCan use 12/24 volt pump with PV module for hot water without electricity

Cons:Contains propylene glycol which must be tested every year and replaced as necessaryWith an oversized system, overheated propylene glycol may become acidic and corrode the copper tubing within the collectors Problematic components prone to failure; specifically expansion tank, air vent, pressure relief valve, check valveLeast efficient system (however, local codes sometimes require double wall)Not always reliable due to overheating

Pros: Maintenance freeProtects from overheatingProtects from freezingProtects from aggressive potable water which allows for extended life of systemFewer system components. Includes pump and control in the solar loopNon pressurizedAlways reliable

Cons:All collectors and pipe runs must be sloped to drain (1/4” per foot)Requires high head pump (1.4 Amp) due to non-pressurized system design

*Manufacturer preferred product.**

***

****

*

*

*

*

*

*****

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 19

Page 20: Aet catalog 2012

www.EagleSunSystem.com

DX-SK Kit Includes:CP-003ST4 1/10 HP SS pump

110-251G 3/4” Flange set

BD-753/4” Boiler drain

DB-10-10XC 10 Gal reservoir with HE

Choose Controller and Pump

{CP-009F Taco High Head Solar Pump

DTC-GL30-LCO Goldline DifferentialControl with Sensor

CP-009VT5Variable Speed Pump with

Built in Control and SensorsSK1 {SK3

DX-80-SK1 DX-80-SK3 DX-120-SK1 DX-120-SK3

Choose your Tank Size

OST-80TCSC 80 Gallon Storage TankOST-120TCSC 120 Gallon Storage Tank

System Kit to Order

DX System Submerged Heat Exchanger, Double Pump

OG300 Certified*

*When paired with certain collector sizes, with 2 thermometers and an antiscald valve. See AET’s websitefor a system certification list.

Page 21: Aet catalog 2012

The DX system is an indirect closed loop system, and is currently the most efficient indirect system on the market. Featuring active dual flow heat exchange with a finned copper heat exchanger.Method of heat exchange:The “DX” Systems’ Drainback reservoir contains a built-in heat exchanger. As the heat transfer fluid is circulated through the solar collector loop, water is circulated from the storage tank through the finned coil heat exchanger inside the reservoir.

DX system features:Gravity removes all water from the collectors,and their pipe lines to ensure they never freeze when the system is not capturing heat. Each time the pump shuts off, the water in the collector(s) and piping, which are mounted at a slight angle, drains into the insulated reservoir. A sight glass attached to the reservoir tank indicates that the collector(s) has been completely drained.A controller is used in these systems to sense when the temperature at the top of the collectors is hotter than the water in the bottom of the storage tank and if the storage tank is at the desired temp. When the collector temp is 8°F-12°F hotter than the storage the pump turns on and when the difference is less than 3°F-5°F the pump turns off.

DX Drainback SystemNon Pressurized Closed Loop

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 21

Page 22: Aet catalog 2012

www.EagleSunSystem.com

DB-SK Kit Includes:

110-251G 3/4” Flange set

BD-753/4” Boiler drain

DB-10C 10 Gal reservoirW/ HX

Choose Controller and Pump

{CP-009F Taco High Head Solar Pump

DTC-GL30-LCO Goldline DifferentialControl with Sensor

CP-009VT5Variable Speed Pump with

Built in Control and SensorsSK1 {SK3

DB-80-SK1 DB-80-SK3 DB-120-SK1 DB-120-SK3

Choose your Tank Size

TM-80HE-1 80 Gallon Storage tank TM-120HE-1 120 gallon Storage Tank

System Kit to Order

DB SystemIndirect DB Kit: Double Wall Heat Exchanger, Single Pump

OG300 Certified*

*When paired with certain collector sizes, with 2 thermometers and an antiscald valve. See AET’s websitefor a system certification list.

Page 23: Aet catalog 2012

The DB System is an indirect, closed loop system utilizing gravity as the underlying force. Method of heat exchange: the “DB” Drainback Systems’ storage tank contains a double wall wrap around heat exchanger. Heat transfer fluid is circulated through the solar collector loop, and then through the heat exchanger in the storage tank. Having a double wall wrap around heat exchanger is an option for code requirements with those states where it is mandatory.

DB system features:

Gravity removes all water from thecollectors, and their pipe lines to ensure they never freeze when the system is not capturing heat. Each time the pump shuts off, the water in the collector(s) and piping, which are mounted at a slight angle, drains into the insulated reservoir. A sight glass attached to the reservoir tank indicates that the collector(s) has been completely drained.A controller is used in these systems to sense when the temperature at the top of the collectors is hotter than the water in the bottom of the storage tank and if the desired temp has been reached. When the collector temp is 8°F-12°F hotter than the storage the pump turns on and when the difference is less than 3°F-5°F the pump turns off.

DB Drainback SystemNon Pressurized Closed Loop

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 23

Page 24: Aet catalog 2012

www.EagleSunSystem.com

BD-753/4” Boiler drain

DBS-1010 Gal reservoir

Choose Your Tank Size

DBS-60-SK3DBS-80-SK3DBS-120-SK3

TM-60SS-HE (60 gallon w/ Heat Exchanger)TM-80SS-HE (80 gallon w/ Heat Exchanger)TM-120SS-HE (120 gallon w/ Heat Exchanger)

System Kit to Order

DBS-SK Kit Includes:110-251G 3/4” Flange set

CP-009VT5Variable speed pump withcontrol and built in sensors

Stainless Steel Tanks- Single Wall Heat Exchanger & Single Pump

DBS SystemOG300 Certified*

*When paired with certain collector sizes, with 2 thermometers and an antiscald valve. See AET’s websitefor a system certification list.

Page 25: Aet catalog 2012

This new and innovative system combines the advantages of the DB and the DX Drainback systems. While only having one pump, this system is still efficient with its single wall heat exchanger. Other systems like the DX require two pumps and while the DB system has a double wall heat exchanger. This system is comprised of not only a stainless steel storage tank and Drainback reservoir, but also a stainless steel heat exchanger inside the storage tank. The warranty on this system is ten years on major components such as the collectors, drainback reservoir, and storage tank.

The system features tanks with an immersed stainless steel heat exchanger and a durable plastic jacket to prevent dents and rust.

This new system features an efficient single wall heat exchanger with a single pump! The best of both the DB and DX Systems combined!

DBS Drainback SystemNon Pressurized Closed Loop

DBS-1010 Gal reservoir

110-251G 3/4” Flange set

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 25

Page 26: Aet catalog 2012

www.EagleSunSystem.com

DX-R Kit Includes:

110-251G 3/4” Flange set

BD-753/4” Boiler drain

CP-003ST4Taco 003 pump

Choose Controller and Pump

{CP-009F Taco High Head Solar Pump

DTC-GL30-LCO Goldline DifferentialControl with Sensor

CP-009VT5Variable Speed Pump with

Built in Control and SensorsSK1 {SK3

DX-10R1 DX-10R3 DX-15R1 DX-15R3

Choose your Drainback Reservoir

System Kit to Order

DB-10-10XC 10 Gallon w/ 10 Sq Ft Heat Exchanger DB-15-15XC 15 Gallon w/ 15 Sq Ft Heat Exchanger

10 Gallon is for 100 sq ft (or less) of collector area15 Gallon is for 104-150 sq ft of collector area

DX Drainback RetrofitSubmerged Heat Exchanger, Double Pump

26

Page 27: Aet catalog 2012

The DX Drainback Retrofit Kit is great for existing water heaters which are fairly new and do not need to be replaced. A drainback reservoir with a heat exchanger is installed close to the storage tank. This makes the system closed loop, meaning the potable water will not come into contact with the liquid in the collectors. This system can be installed by any licensed solar installer.

DX Retrofit System

Features:Easy modification to an existing hot water system. All the benefits of a standard DX system. A controller is used in these systems to sense when the temperature of the collectors are hotter than the water in the bottom of the storage tank. When the temperature is 8°F-12°F hotter in the collector the pump turns on and when the difference is less than 3°F-5°F or the pump turns off.

DX Drainback Retrofit KitNon Pressurized Closed Loop

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 27

Page 28: Aet catalog 2012

www.EagleSunSystem.com

I-SK Kit Includes:110-251 3/4” Flange set

BD-50 (2)1/2” Boiler drain

CP-008FTaco 008 pump

ET-202.0 Gal Expansion Tank

CV-501/2” Check Valve

PG100Pressure Gauge

BV-50 (2)1/2” Ball Valve

PR-150 3/4” Pressure Relief Valve

AV-1501/4” Air vent

DTC-GL30-LCOGoldline Differential Control with Sensors

Choose your Tank Size

TM-80HE-1 80 Gallon Storage tank TM-120HE-1 120 gallon Storage Tank

I-80-SK I-120-SKSystem Kit to Order

Indirect PressurizedIndirect Pressurized Glycol, Double Wall System Kit (AC)

28

Page 29: Aet catalog 2012

The “I” system is an indirect Pressurized Glycol System that utilizes an AC pump and controller for accuracy. Indirect Pressurized System Features:Accommodates climates where freezing weather occurs.A controller is used in these systems to sense when the temperature of the fluid in the collectors is hotter than the water in the bottom of the storage tank. When the differential is 8°F-12°F hotter in the collector the pump turns on and when the difference is less than 3°F-5°F the pump turns off. An integrated wrap around heat exchanger inside the storage tank transfers heat from the solar loop to water in the storage tank. Water is the best heat transfer fluid, however glycol can be used to prevent freezing inside the supply and return lines.

Indirect Pressurized Glycol Pressurized Closed Loop

110-251 3/4” Flange set

CV-501/2” Check Valve

BV-50 (2)1/2” Ball Valve

AV-1501/4” Air vent

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 29

Page 30: Aet catalog 2012

www.EagleSunSystem.com

I-SKSPS Kit Includes:

ET-202.0 Gal Expansion Tank

Choose your Tank Size

TM-80HE-1 80 Gallon Storage tank TM-120HE-1 120 gallon Storage Tank

I-80-SKSPS I-120-SKSPSSystem Kit to Order

Indirect Pressurized SPSIndirect Pressurized Glycol, with Solar Pumping Station

CP-SPSEagleSun Solar Pumping Station:

Built in Flow Meter008 Varialbe Speed Pump Integrated Control and SensorsPresssure Relief ValvePressure Gauge(2) Temperature GaugesAir Vent

Insulation

3412BPA3/4 x 1/2 Bushing

30

Page 31: Aet catalog 2012

The “I-SPS” System is an Indirect Pressurized Glycol System that utilizes a simple, prefabricated pumping station.Indirect Pressurized System with Pumping Station Features:Accommodates climates where freezing weather occurs. A controller is used in these systems to sense when the temperature of the fluid in the collectors is hotter than the water in the bottom of the storage tank. When the differential is 8°F-12°F hotter in the collector the pump turns on and when the difference is less than 3°F-5°F the pump turns off. An integrated wrap around heat exchanger inside the storage tank transfers heat from the solar loop to water in the storage tank. Water is the best heat transfer fluid, however glycol can be used to prevent freeezing inside the supply and return lines. This solar pumpingstation incorporatesthermometers, a flow meter, and comes pre fabricated, which eleminates guess work and reduces labor costs on the job.

Indirect Pressurized Glycol SPS Pressurized Closed Loop

3412BPA3/4 x 1/2 Bushing

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 31

Page 32: Aet catalog 2012

www.EagleSunSystem.com

IPV-SK Kit Includes:PV-1010 Watt PV Module

BD-50 (2)1/2” Boiler drain

CP809-2424V DC March Pump

ET-202.0 Gal Expansion Tank

CV-501/2” Check Valve

PG100Pressure Gauge

BV-50 (2)1/2” Ball Valve

PR-150 3/4” Pressure Relief Valve

AV-1501/4” Air vent

Choose your Tank Size

TM-80HE-1 80 Gallon Storage tank TM-120HE-1 120 gallon Storage Tank

IPV-80-SK IPV-120-SK

System Kit to Order

Indirect Pressurized Glycol, (PV)Double Wall System Kit

Indirect Pressurized (PV)

32

Page 33: Aet catalog 2012

PV-1010 Watt PV Module

CV-501/2” Check Valve

AV-1501/4” Air vent

The “IPV” is a type of Residential Solar Hot Water System referred to as “indirect” because the sun, through a roof-mounted collector, heats fluid circulating in a closed off solar loop that never comes in direct contact with usable water stored in an insulated tank.

IPV System Features:

Accommodates climates where freezing weather occurs more frequently.

An integrated wrap around heat exchanger inside the storage tank transfers heat from the solar loop to water in the storage tank. Water is the best heat transfer fluid, however glycol can be used to prevent freeezing inside the supply and return lines. A small PV panel (which generates electricity from the sun) is available to operate the circulation pump, further reducing traditional energy consumption.

Indirect Pressurized Glycol (PV) Pressurized Closed Loop

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 33

Page 34: Aet catalog 2012

www.EagleSunSystem.com

D-SK Kit Includes*:BD-501/2” Boiler drain

CP-003ST4Taco 003 pump

BV-501/2” Ball Valve

PR-150 3/4” Pressure Relief Valve

AV-1501/4” Air vent

D-80-SKD-120-SK

Choose your Tank Size

OST-80TCSC 80 Gallon Storage TankOST-120TCSC 120 Gallon Storage Tank

System Kit to Order

DTC-GL30-LCOGoldline Differential Control with Sensors

Direct PressurizedOpen Loop (AC) For Non Freezing Climates *NO Guaranteed Freeze Protection*

*Installers should still source a vacuum breaker and freeze protection valve.34

Page 35: Aet catalog 2012

BV-501/2” Ball Valve

AV-1501/4” Air vent

The Direct Series systems, found in Tropical Climates, are referred to as direct because the sun’s heat is transferred through the collector directly to the usable water. When there is sufficient heat in the collectors, a pump circulates water from the bottom of a storage tank through collectors where it is heated, and then returns to the tank for storage and eventual use.

Direct System

Features:

A differential control senses temperature differences between water leaving the collector and the coldest water in the bottom of the storage tank. When the temperature of the water in the collector is hotter than the water in the tank, the differential control operates the circulating pump. Freeze protection includes, automatic recirculation, thermally operated valve installed at the collector (where required) or by manually draining, and a properly installed collector.

Direct PressurizedOpen Loop

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 35

Page 36: Aet catalog 2012

www.EagleSunSystem.com

DPV-SK Kit Includes*:BD-501/2” Boiler drain

CP-003ST4Taco 003 pump

BV-501/2” Ball Valve

PR-150 3/4” Pressure Relief Valve

AV-1501/4” Air vent

PV-1010 Watt PV Module

Choose your Tank Size

OST-80TCSC 80 Gallon Storage TankOST-120TCSC 120 Gallon Storage Tank

System Kit to Order

DPV-80-SKDPV-120-SK

Open Loop PV For Non Freezing Climates *NO Guaranteed Freeze Protection*

Direct Pressurized (PV)

*Installers should still source a vacuum breaker and freeze protection valve.36

Page 37: Aet catalog 2012

BV-501/2” Ball Valve

AV-1501/4” Air vent

The Direct Series systems, found in Tropical Climates, are referred to as direct because energy from the sun is transferred through the collector directly to the potable water. When there is sufficient heat in the collectors, a pump circulates water from the bottom of a storage tank through collectors where it is heated, and then returned to the tank for storage and eventual use.

DPV System

Features:

Freeze protection includes a thermally operated valve installed at the collector (where required) or by manually draining a properly installed collector.A PV panel (which generateselectricity from the sun) option is available to operate the circulation pump, further reducing traditional energy consumption.

Direct Pressurized (PV)Open Loop

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 37

Page 38: Aet catalog 2012

www.EagleSunSystem.com

(1) AE-26 EF 4 x 6.5 Collector FF (1) AE-FF Flush Mount Hardware (1) FF-50C 50 Gallon Glass Lined Tank without

Electrical Backup (1) FF-tank stand Free Flow Tank Stand (1) FF-TK Free Flow Tank Kit

(1) AE-26 CF 4 x 6.5 Collector FF (1) AE-FM Flush Mount Hardware (1) FF-PK Free Flow Plumbing Kit (1) FF-50SS 50 Gallon Stainless Steel

Tank with Electrical Backup

(1) AE-32EF 4 x 8 Collector FF(1) AE-FM Flush Mount Hardware(1) FF-80SS 80 Gallon Glass Lined Tank

with Electrical Backup(1) FFPK Free Flow Plumbing Kit

(1) AE-21-T3L 3 x 7 Collector 3 Outlet(1) AE-FM Flush Mount Hardware(1) FF-PK Free Flow Plumbing Kit(1) FF-80SS 80 Gallon Stainless Steel

Tank with Electrical Backup

FF-80SS-42

FF-80SS-32

FF-50SS-26

FF-50-26

Suggested additional components for all systems: (Roof flashings are great for shingle roofs)

RF-50 or RF-75: Roof flashing packageAM101T: Anti-scald valve

T-60: Thermometer

Thermosiphon SystemsPassive Free Flow Systems*NO Guaranteed Freeze Protection*

38

Page 39: Aet catalog 2012

The Free Flow Series is a Thermosiphon system. As a self-contained solar water heating system, the Free Flow Systems have collector(s) positioned lower than the tank(s), sloped at a minimum of 10°, and operate on the principle of natural convection. As the sun heats the water in the collector, it becomes less dense, causing the water to rise into the tank. The colder, heavier, water in the bottom of the tank then sinks into the bottom of the collector. These events create a continuous natural circulation.

Free Flow System Features:

Thermosiphon systems are widely accepted throughout the world today. They are automatic, simple, and reliable.

Thermosiphon Systems do not require a pump or a controller.

There are no moving parts, which allows for little to no maintenance concerns.

The FF-50SS and FF-80SS (50 & 80 gallons) are stainless steel with an electrical backup element.

Thermosiphon SystemOpen Loop

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 39

Page 40: Aet catalog 2012

EagleSun™ Pool Heating

40

Page 41: Aet catalog 2012

Swim LongerInstalling a solar pool heating system will increase, sometimes even double, the amount of time your swimming pool can be comfortably used during the year.

EconomicalWhen compared to heating your pool with other methods, solar heating can pay for itself in as little as 3 years.

Environmentally SafeSolar Pool heaters use solar energy to provide a clean energy alternative to conventional heating sources that pollute the environment.

Maintenance FreeOnce the panels are installed, you can relax in your warm pool without any additional maintenance or cost involved.

QualityWith up to 35% more polypropylene and UV stabilizers than any other manufacturer, EagleSun™ Pool Panels keep your pool heated longer and have a longer life expectancy.

Hurricane TestedEagleSun™ panels can withstand hurricane force winds of 159.6 mph!

GuaranteeEagleSun™ Products are backed by a comprehensive 10 Year Limited Lifetime Warranty to ensure years of enjoyment.

Benefits

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 41

Page 42: Aet catalog 2012

1. Efficiently absorbed heat is transferredto the pool water circulating through the collectors.

2. Manual Control: Turns the pool heatingsystem on or off as required.

3. Pump and Filter: Circulate clean waterto the pool and collector when required.

4. Check Valve: Used to prevent back flowcirculation in the solar collectors at night and allows for sustained drainage.

5. EPDM Collector Hoses: Join the solarcollectors together and connect the supply and return piping to the collector array.

6. Long Mounting Straps: Used to securethe solar collectors to the roof.

7. Header Straps: Installed on the topheader of the solar collectors only. Used to bear the weight of the collector.

8. Stainless Clips: Used to secure themounting straps to the roof. Roof sealant is used to assure the integrity of the roof.

Pool Heating System

42

Page 43: Aet catalog 2012

Kit Includes Qty Kit Includes Qty Kit Includes QtyRubber Hose 2 Rubber Hose 2 Vacuum Breaker 1Hose Clamp 4 Hose Clamp 4

LAG Screw 5 LAG Screw 5 Strap Clip 3 Strap Clip 3 Pipe Strap 1 Pipe Strap 1

Pipe-to-Panel Adapter 2Grooved Plug 2

Panel Kit(1 per panel)

System Kit(1 per system)

Vacuum Breaker Kit(1 per system)

2.0” Header Solar Panel

Overall Length:ES-48P 144”ES-40P 120.25”ES-32P 95.88”

Header Outside Diameter: 2.31”Header Length: 50.75”

Technical Information

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 43

Page 44: Aet catalog 2012

FeaturesMost pool heating panels are designed to be repaired...Eagle Sun Pool Panels are designed to last.

The majority of solar pool heaters are designed with “individual” round flow tubes so that if a tube leaks it can easily be plugged. Some manufacturers even state in their warranty that a damaged system will be repaired if possible. In most cases a “repair” is nothing more than a plug. The problem with this is that a plugged panel is much less efficient or effective at heating your pool.

Another problem with the design of most solar pool heating systems is that the shape and thickness of the flow tube walls do not allow for prolonged expansion or contraction that occurs during seasonal temperature changes or extreme weather such as freezing. This patented flat panel design is proven to be more efficient and more durable than other solar pool heaters.Here’s why: Absorb more heatEagle Sun Pool collectors are visibly thicker than any other pool heating collector because we use up to 35% more raw materials in our panels. This attracts more heat. Reduce heat loss Eagle Sun flow tubes are connected so that they stay warm longer. Other panels can cool rapidly during windy conditions because the “individual” flow tubes aren’t insulated by each other.Last longerThe extra material in our panels allows for greater expansion and contraction, provides extra UV protection and prevents weak spots.Prevent freeze damage (covered under warranty) Because water expands by approximately 9% when turning to ice, the strain put on a solar panel’s flow channel can be devastating. Our pool heaters, however, are designed to withstand internal freezing better than any other panel on the market today. As the picture to the right illustrates, the 2 keys to our durability are the thickness of our panels and the shape of the flow channels.

44

Page 45: Aet catalog 2012

Size 4 x 12 4 x 10 4 x 8Part # ES-48P ES-40P ES-32P

DIMENSIONS Units Overall Length In 144 120.25 95.88Absorber Width In 47.63 47.63 47.63Header Length In 50.75 50.75 50.75Header OD In 2.31 2.31 2.31Header ID In 1.89 1.89 1.89Gross Area Sq ft 47.725 39.87 31.809Net Area Sq ft 47.625 39.77 31.709Number of Flow Channels 104 104 104Nominal Hole Size In 0.156 0.156 0.156WEIGHT Dry Lbs 30 25 20Wet Lbs 64.4 55.5 46.6Wet Dispersed Lbs/sq ft 1.31 1.35 1.41Fluid Capacity Gal 4.13 3.66 3.19FLOW RATES Max Gpm 10 10 10Min Gpm 3 2.5 2.5Recommended Gpm 4.95 4.95 4.95Max # panels in parallel Panels 10 12 14PRESSURE Drop Psi 0.15 0.15 0.15Max test Psi 80 80 80Max operating range Psi +/- 10 +/- 10 +/- 10Max operating spike Psi 35 35 35PERFORMANCE FSEC Certification BTU/day 45600 38100 30400Wind Load mph 150 150 150

All Panels have a (2.0” Header)

Specifications

Panel

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 45

Page 46: Aet catalog 2012

46

Alternate Energy Technologies, LLCTo: AET, Attn: Sales Department, Fax: 904-529-9837, Email: [email protected]

Purchase Order / Quote Request (Choose One)

Bill To ______________________ Ship To______________________ Address:____________________ Address:_____________________ ___________________________ ____________________________ Ph:________________________ Ph:_________________________

Email:______________________Residential Delivery? Lift Gate Service?

Shipping Method Terms PO # or Job Name Ordered By _____________ Prepay* _______________ __________

Notes:

Qty Part Description Price Amount___ _________ __________________________ ______________ _________ __________________________ ______________ _________ __________________________ ______________ _________ __________________________ ______________ _________ __________________________ ______________ _________ __________________________ ______________ _________ __________________________ ______________ _________ __________________________ ______________ _________ __________________________ ______________ _________ __________________________ ___________

SUBTOTAL ___________

CRATING (Packaging) ___________

TOTAL ___________

Freight Collect unless previously discussed. *Prepay with Credit Card (see below.)

Credit Card information

Account number________________________ Exp Date______________ Billing address__________________________________________________________ Security Code__________________

Page 47: Aet catalog 2012

Roush Racing, Beaver Brothers NAS Jax, Florida Solar Services

Manaheim Car Wash, Suncatcher of Atlanta and Solar Service Inc.

Dallas City Library, Sunrise Solar

Solar Service Inc Solar Service of New England

Housing Authority of Chester County, Solar Energy Services

Radiantec

Alternate Energy Technologies 904-297-9369 www.aetsolar.com 47

Page 48: Aet catalog 2012

www.aetsolar.com

America’s Choice for Solar Water Heating

Systems.

Alternate Energy Technologies1345 Energy Cove Court, Green Cove Springs, FL 32043

P: 904-781-8305/800-874-2190 F: 904-781-1911