afs overview 1kha-001 138-sen-0110 internal
TRANSCRIPT
www.abb.com/utilitycommunications
Basic Options
– 670: FE Version– 675: GbE Version– 677: 16 x Ports GbE Version
Power over Ethernet Option (PoE)
– P: PoE (Slot 1 & 2 need to be of „T“ Type; PS need to be of „H / Z“ type)– E: No PoE
Mounting Option
– R: Ports on rear side– E: Ports on front side
Gigabit Ethernet (GbE) Option
– CP: 2 x GbE Combo Ports– GP: 4 x GbE SFP cages– GT: 4 x 10/100/1000 BaseT Ports– GS: 2 x GbE SFP cages & 2 10/100/1000 BaseT Ports– EE: No GbE Ports (AFS670/677)
Port Options
– T: 2 x Ports 10/100BaseT– D: 2 x Ports FE SC, MM (8 dB)– F: 2 x Ports FE SC, SM (16 dB)– I: 2 x Ports FE SC, SM, Long haul (7-29 dB)– K: 2 x Ports FE SC, SM, extra Long haul (14-47 dB)– A: 2 x Ports FE ST, MM (8 dB)– B: 2 x Ports FE ST, SM (16 dB)– S: 2 x SFP cages– U: 2 x Ports FE MTRJ, MM (8 dB)– V: 2 x Ports FL ST, MM (9.5 dB)– M: 2 x Ports FE M12 connector– E: Slot empty
Temperature Options
– N: Temperature range 0°C – 60°C– P: Temperature range -40°C – 85°C– Z: Temperature range -40°C – 85°C incl. Conformal coating
Power Supply Options
– L: Low voltage PS (9,6–60VDC), spring clamps– H: High Voltage PS (77–320VDC, 90–265VAC), spring clamps– Y: Low Voltage PS (9,6–60VDC), connector– Z: High Voltage PS (77–320VDC, 90–265VAC), connector– E: No redundant PS
Future Option
– X: Default
Firmware Option
– Firmware release
Management Ports
– USB Port for CRA (Configuration Recovery Adapter)– V.24 Port for Management– 2 x Alarm Switchover Contacts (230VAC, 2A)
Protection Features
IEEE802.1w Rapid Spanning Tree Protocol (RSTP)IEC62439 Media Redundancy Protocol (MRP)E-MRP Enhanced MRP
E-MRP Performance:Ring with < 10 Devices: Switch over time < 10msRing with < 100 Devices: Switch over time < 40ms
Redundant coupling of several E-MRP rings is supported. Network topo-logy consisting of a main ring and subrings is also supported (up to 4 subring ports per device). Each device supports multiple protection proto-cols (e.g. E-MRP on port 1 & 2, MRP on port 3 & 4).
For more details please refer to the AFS user manual.
Utility grade Switch
IEC61850 approvedIEEE1613 approved
EMC/ EMIEN61000-4-2 (ESD): 8kV contact discharge,15kV air dischargeEN61000-4-3: 35Vpp/m (80–2700 MHz); 1kHz, 80% AMEN61000-4-4 (Burst): 4kV power line, 4kV signal- und data lineEN61000-4-5 (Surge): power line: 2kV (line/earth),1kV (line/ line)EN61000-4-12: 2,5kV line/earth,1kV line/line (1MHz)EN61000-4-16: 30V; 50Hz continous; 300V, 50Hz 1sIEEE C37.90 HV impulse ±5 kV line/earthIEEE C37.90.1 Burst ±4 kV, damped vibr. ±2.5 kV line/earth, ±1 kV line/lineIEEE C37.90.2 Electromagnetic field 80 - 1000 MHz 35 v/m (peak)IEEE C37.90.3 ESD; contact discharge ±8 kV; air discharge ±15 kV
Mechanical TestsIEC60068-2-27 Shock: 15g,11ms duration,18 ShocksIEC60068-2-6 Vibration: 1mm, (2–13,2Hz), 90min.; 0,7g, (13,2–100Hz), 90min.; 3,5 mm, (3–9Hz),10 cycles, 1 octave/ min.; 1g, (9–150Hz),10 cycles,1 octave/min.
Applicable Standards
IEEE802.1d MAC BridgesIEEE802.1D/p Port PriorityIEEE802.1D Switching, GARP, GMRP, Spanning Tree (Supported via 802.1S implementation)IEEE802.1Q-1998 Virtual Bridged Local Area Networks (VLAN Tagging, Port Based VLANs, GVRP)IEEE802.1x Port AuthenticationIEEE802.1AB Topology Discovery (LLDP)IEEE802.3 – 2002 EthernetIEEE802.3ac VLAN TaggingIEEE802.3ad Link AggregationIEEE802.3af Power over Ethernet (PoE)IEEE1588 Precision Time Protocol (PTP)Radius Centralized Password ManagementRMON Remote MonitoringSNMP V1/V2/V3 Simple Network Management ProtocolSNTP Simple Network Time Protocol
Available SFPs
Normal Temperature Range 0°C – 60°CFAST SFP-MM LC: FE, MM, 1310nm, 0-8dBFAST SFP-SM LC: FE, SM, 1310nm, 0-13dBFAST SFP-LH LC: FE, SM, 1550nm, 10-29dBFAST SFP-SM+ LC: FE, SM, 1310nm, 10-29dB
SFP-SX LC: GbE, MM, 850nm, 0-7.5dBSFP-LX LC: GbE, MM, 1310nm, 0-11dBSFP-LH LC: GbE, SM, 1550nm, 6-22dBSFP-LH+ LC: GbE, SM, 1550nm, 13-32dB
Extended Temperature Range -40°C – 85°CFAST SFP-LH LC EEC: FE, SM, 1550nm, 10-29dBFAST SFP-MM LC EEC: FE, MM, 1310nm, 0-8dBFAST SFP-SM LC EEC: FE, SM, 1310nm, 0-13dBFAST SFP-SM+ LC EEC: FE, SM, 1310nm, 10-29dB
SFP-LH LC-EEC: GbE, SM, 1550nm, 6-22dBSFP-LX LC EEC: GbE, MM, 1310nm, 0-11dBSFP-SX LC EEC: GbE, MM, 850nm, 0-7.5dB
A F S 6 7 5 - E R G T T T S U D A E E E E E E N Z Z X 0 5 . 0 1
1KH
A -
001
138
- S
EN
- 0
1.10
- P
rinte
d in
Sw
itzer
land
© A
BB
Sw
itzer
land
Ltd
, Jan
uary
201
0. T
he r
ight
to m
odifi
catio
ns o
r de
viat
ions
due
to te
chni
cal p
rogr
ess
is re
serv
ed.
ABB FOX Switch (AFS) Family for utility applicationsAFS670 / AFS675 Overview
Electrical Port Options
10/100 BaseT
M12 connector
Ports on rear sidePorts on front side
SFP cage
MTRJ connector
Optical Port Options
SC connector
ST connector
For ABB internal use only!
www.abb.com/utilitycommunications
1KH
A -
001
138
- S
EN
- 0
2.10
- P
rinte
d in
Sw
itzer
land
© A
BB
Sw
itzer
land
Ltd
, Feb
ruar
y 20
10. T
he r
ight
to m
odifi
catio
ns o
r de
viat
ions
due
to te
chni
cal p
rogr
ess
is re
serv
ed.
ABB FOX Switch (AFS) Family for utility applicationsAFS650 / AFS655 Overview
Basic Options
– 650: FE Version– 655: GbE Version
Port Amount
– 6: 6 x 10/100 BaseT Ports (only AFS655)– 7: 7 x 10/100 BaseT Ports (only AFS655)– 8: 8 x 10/100 BaseT Ports– 9: 9 x 10/100 BaseT Ports (only AFS650)
Uplink 1 Option
AFS650
AFS650-8– ED: 1 x Port FE SC, Multimode– EF: 1 x Port FE SC, Singlemode– EI: 1 x Port FE SC, Singlemode, Long Haul– EK: 1 x Port FE SC, Singlemode, extra Long Haull– EA: 1 x Port FE ST, Multimode– EB: 1 x Port FE ST, Singlemode–– EU: 1 x Port FE MTRJ, Multimode
AFS655
AFS655-6AFS655-7AFS655-8– 2C: 2 x GbE Combo Ports– 2G: 2 x GbE SFP cage
Temperature Options
– N: Temperature range 0°C – 60°C– P: Temperature range -40°C – 85°C– Z: Temperature range -40°C – 85°C incl. Conformal coating
Power Supply Options (only connector)
– LL: Redundant Low Voltage PS (18VDC - 60VDC)– HH: Redundant High Voltage PS (48VDC - 320VDC or 90VAC - 265VAC)– HE: Single High Voltage PS, spring clamps
Future Option
– X: Default
Firmware Option
– Firmware release
Management Ports
– USB Port for CRA (Configuration Recovery Adapter)– V.24 Port for Management– 2 x Alarm Switchover Contacts (230VAC, 2A)
Applications
Substation Automation
Establish a Fast Ethernet or Gigabit Ethernet Backbone to provide com-munication for IEC61850 Substation Automation applications such as:
– GOOSE messages– Sampled Values (SV)– Client Server communication
Distribution Communication
Establish a Wide Area Network based on Fast Ethernet or Gigabit Ethernet to provide communication for Distribution SCADA System appli-cations such as:
– IEC60870-5-104 data communication– Operational telephony system– Metering
In Plant Communication
Establish a Local Area Network based on Fast Ethernet or Gigabit Ethernet to provide communication for In Plant applications such as:
– CCTV system– Public Announcement System– In Plant telephony system
Glossary
Combo Port SFP cage & electrical portE-MRP Enhanced MRP GbE Gigabit Ethernet (1000Mbps)MM MultimodeMRP Media Redundancy ProtocolPoE Power over EthernetRSTP Raid Spanning Tree ProtocolSM Singlemode VLAN Virtual LAN
Additional Port Option
– T: 6 x 10/100BaseT– S: 6 x FE SFP cage (AFS655 only)
Uplink 2 Option
AFS650
AFS650-8AFS650-9– ED: 1 x Port FE SC, Multimode– EF: 1 x Port FE SC, Singlemode– EI: 1 x Port FE SC, Singlemode, Long Haul– EK: 1 x Port FE SC, Singlemode, extra Long Haul– EA: 1 x Port FE ST, Multimode– EB: 1 x Port FE ST, Singlemode– EU: 1 x Port FE MTRJ, Multimode
A F S 6 5 5 - 6 2 C E C T N H H X 0 5 . 0 1
Customer Benefits
Utility Grade Products, specially designed for substation environment
− High EMC EMI Immunity − Extended temperature range − Redundant power supply available for DIN rail & 19” − AC/ DC power supply − Wide input range of power supply − PoE as an option − Enhanced protection schemes for traffic protection
Very high system availability because of:
− High MTBF of the equipment itself − Fan-less design − Very fast switchover time in case of link disturbance
Scalable port density from 8 to 28 Ports, including GbE functionality
Overall ABB Communication Solution
− Part of ABB Communication Solution Family − Part of ABB Substation Solution
System integration covering all aspects and applications such as SCADA data traffic, IEC61850 or operational telephony. Specially for packet switched solutions design and system integration plays a key role for network performance and availability.
Based on more than 60 years if experience, a broad solution portfolio and intensive application and system testing, ABB offers solutions designed according to utility requirements providing highest system availability.
AFS650-9– 2D: 2 x Ports FE SC, Multimode– 2F: 2 x Ports FE SC, Singlemode– 2I: 2 x Ports FE SC, Singlemode, Long Haul– 2K: 2 x Ports FE SC, Singlemode, extra Long Haul– 2A: 2 x Ports FE ST, Multimode– 2B: 2 x Ports FE ST, Singlemode– 2U: 2 x Ports FE MTRJ, Multimode
AFS655
AFS655-6AFS655-7AFS655-8 – 2S: 2 x FE SFP cage– EC: 1 x GbE Combo Ports– EG: 1 x GbE SFP cage
For ABB internal use only!