VnmrJ BioPack:

The Easiest Path to High Quality BioNMR Data

Evgeny Tishchenko Frank Delaglio

Agilent BioPack eSeminar

Santa Clara August 2013

Page 2: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

VnmrJ 4.0

2

Page 3: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

VnmrJ 4.0 and NMRPipe

3

The NMRPipe engine extends to Bio, Solids, and Small-molecule applications

TALOS+: protein backbone phi,psi torsions

from chemical shifts.

SPARTA+: protein backbone chemical

shifts from structure.

DYNAMO/PDBUTIL: structure analysis and

manipulation, add protons, create

extended structures, etc.

DC: manipulation of Dipolar Couplings,

NMR Homology Search (MFR).

IST: 2D and 3D NUS processing.

Spectral Alignment for CRAFT.

SpecView: 1D and 2D spectral series

analysis with Interactive Principal

Component Analysis Navigation.

SPARTA+

Page 4: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Page 4

TALOS+ predicts protein backbone torsions from chemical shifts using a

combination of database mining and an artificial neural network (ANN).

It can form predictions for 88% of residues on average, with an RMS of

better than 15 degrees. A No-Proton mode tuned for Solid State

applications is included.

Page 5: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Page 5

Page 6: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Page 6

SPARTA+

Page 7: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August
Page 8: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Page 8

• Create Extended Structure

• Add Protons

• Transformations of PDB Coordinates

• List Secondary Structure, H-Bonds

• Mass, Volume, Surface Area

• Simple simulated annealing

Page 9: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Analyze Titration Curve to Estimate Kd

Page 10: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

VnmrJ 4.0 – NMRPipe SpecView

10

1D Series Display with Interactive Principal Component Analysis

Page 11: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

VnmrJ 4.0 – NMRPipe SpecView

11

2D Series Display with Interactive Principal Component Analysis

Page 12: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

VnmrJ 4.0 BioPack and NMRPipe

12

NMRPipe – The Old Way

Page 13: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

VnmrJ 4.0 BioPack and NMRPipe

13

NMRPipe – The Old Way

Manually Select Acquisition Mode

Page 14: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

VnmrJ 4.0 BioPack and NMRPipe

14

NMRPipe – The Old Way

Manually Select Nucleus

Page 15: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

VnmrJ 4.0 BioPack and NMRPipe

15

NMRPipe – The Old Way

Manually Select Axis Label

Page 16: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

VnmrJ 4.0 BioPack and NMRPipe

16

NMRPipe – The Old Way

Traditionally, NMRPipe scripts are manually edited to set parameter values

#!/bin/csh

xyz2pipe -in fid/test%03d.fid -x -verb \

| nmrPipe -fn SOL \

| nmrPipe -fn SP -off 0.5 -end 0.98 -pow 2 -c 0.5 \

| nmrPipe -fn ZF \

| nmrPipe -fn FT \

| nmrPipe -fn PS -p0 43.0 -p1 0.0 -di \

| nmrPipe -fn EXT –x1 10.5ppm –xn 5.7ppm -sw \

| nmrPipe -fn TP \

| nmrPipe -fn SP -off 0.5 -end 0.98 -pow 1 -c 1.0 \

| nmrPipe -fn ZF \

| nmrPipe -fn FT \

| nmrPipe -fn PS -p0 -90.0 -p1 180.0 -di \

| nmrPipe -fn TP \

| nmrPipe -fn POLY -auto \

| pipe2xyz -out ft/test%03d.ft2 -x -to 0

xyz2pipe -in ft/test%03d.ft2 -z -verb \

| nmrPipe -fn SP -off 0.5 -end 0.98 -pow 1 -c 0.5 \

| nmrPipe -fn ZF \

| nmrPipe -fn FT \

| nmrPipe -fn PS -p0 0.0 -p1 0.0 -di \

| pipe2xyz -out ft/test%03d.ft3 -z

Page 17: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

VnmrJ 4.0 BioPack and NMRPipe

17

BioPack and NMRPipe – Automated Construction of Processing Schemes

Automatically Create and Run

NMRPipe Scripts

Page 18: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

VnmrJ 4.0 BioPack and NMRPipe

18

BioPack and NMRPipe – Automated Construction of Processing Schemes

The VnmrJ “Do it All” Button

Page 19: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

VnmrJ 4.0 BioPack and BioPack Express

19

BioNMR Setup and Processing with Just a Few Clicks

Page 20: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

VnmrJ 4.0 and Non-Uniform Sampling

20

Background: the Fourier Transform and Non-Uniform Sampling

X( f ) = S x( t ) [ cos( 2pft / N ) - i sin( 2pft / N ) ]

Page 21: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August
Page 22: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August
Page 23: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

S+ S-

Page 24: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

S+ S-

Page 25: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August
Page 26: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

S+ S-

Page 27: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Page 27

Page 28: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Page 28

Page 29: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Page 29

Non-Uniform Sampling on a Uniform Grid

Page 30: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Page 30

Non-Uniform Sampling: Skip a Fraction of the Points

Page 31: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Page 31

Non-Uniform Sampling

Page 32: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Page 32

Non-Uniform Sampling:

for Fourier Transform, Replace Missing Points with Zeros

Page 33: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August
Page 34: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

S+ S-

Page 35: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Linear versus Non Uniform Sampling

35

Linear Sampling: Broad Line and Periodic Truncation Wiggles

Non Uniform Sampling: Narrow Line and Random Noise-Like Artifacts

Page 36: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Non Uniform Sampling

36

Threshold Methods

Page 37: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Non Uniform Sampling

37

Threshold Methods

Page 38: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Non Uniform Sampling

38

Threshold Methods

Page 39: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Non Uniform Sampling

39

IST – Iterative Soft Thresholding

Fourier Spectrum IST Spectrum

Page 40: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Page 40

Page 41: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Non Uniform Sampling

41

Non-Uniform Sampling and NMRPipe in VnmrJ 4

Pulse sequence-independent data acquisition:

o Works seemlessly with every experiment, automatically.

o Effortless - just set check a NUS checkbox in the graphical interface.

o Comprehensive set of options for sampling schedules, including any

user-supplied schedule.

o NMRPipe Users - No need to figure out data acquisition order, reshuffling

dimensions etc… No hassle, just press the processing button.

o NUS Reconstruction is handled automatically – no need to download and

learn complicated signal processing software packages from academic

labs, no need to construct NMRPipe scripts by hand.

Page 42: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express – Introduced at ENC 2013

42

Page 43: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

43

An overview

BioPack:

An comprehensive software framework for automated, optimized

bioNMR measurement setup, with fully-automated, supllemented

with the most extensive library of pulse sequences. BioPack

provides expert users with ultimate control over all experimental

parameters.

BioPack Express:

A streamlined enhancement to BioPack that allows a user to acquire

the most commonly used bioNMR experiments with near optimum

performance and minimum operator involvement.

Page 44: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

44

BioPack Express fundamentals

A vast majority of bioNMR experiments require very few “input

parameters” in order to get decent results:

o What experiments to run (i.e. HNCA, HSQC , etc.)

o Spectrometer time available (i.e. nt, NUS or not)

o One or two “specials” per experiment (ex. mixing time in

TOCSY/NOESY, max T2 in CPMGs, etc.)

Everything else can be predicted based on knowledge about the nature

of a particular experiment and spectrometer calibrations

Page 45: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

45

A single panel is sufficient to acquire, and process the most widely-used experiments

Page 46: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

46

BioPackExpress Features

o Intuitive high-level user interface that allows a user to set up and run a

bioNMR experiment or a queued set of experiments with a few clicks of

a button.

o NUS made easy: automatic experiment-specific and pulse-sequence

independent set-up for Non-Uniform data acquisition and processing.

o Automatic set-up of data processing parameters.

o Top-level acquisition and processing algorithms are experiment-specific

and can be easily customized, while a unified graphical interface is used

for all experiment types.

Page 47: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

47

In most cases one would need only one panel

Quick calibration of 1H pw90 (needed once per sample)

Page 48: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

48

In most cases one would need only one panel

Key experiment parameters

Page 49: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

49

In most cases one would need only one panel

Non-Uniform Sampling

Page 50: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

50

In most cases one would need only one panel

Human-readable choices of experiment modes (experiment-specific!)

Page 51: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

51

In most cases one would need only one panel

Human-readable options for data processing (dataset-specific!)

Page 52: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

52

In most cases one would need only one panel

Hint/info line

Page 53: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

53

How to setup a single experiment

Page 54: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

54

Page 55: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

55

How to setup a queue of experiments

Page 56: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

56

Page 57: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

57

How to process

a multidimensional dataset

Page 58: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

58

How to process

a multidimensional dataset

Page 59: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

59

How to process

a multidimensional dataset

acquired using Non-Uniform Sampling

( NUS)

Page 60: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

BioPack Express

60

Page 61: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Agilent VnmrJ BioPack Express

61

The Most Widely-Used BioNMR Experiments in Just a Few Mouse Clicks

Shown here:

o NUS HNCO

o NUS HNCACB

o NUS HNCA

o NUS HC(CO)HN

o N15NOE

Page 62: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Agilent Spinsights NMR Community

62

https://spinsights.chem.agilent.com

Note: registration is required to access the Spinsights online community.

More Questions?

Join the Spinsights NMR Community and

Help Yourself, Help Each Other, or Ask

Agilent

Page 63: Agilent Technologies · Agilent Technologies VnmrJ BioPack: The Easiest Path to High Quality BioNMR Data Evgeny Tishchenko Frank Delaglio Agilent BioPack eSeminar Santa Clara August

Thank You!

63